Force FS Series Installation and Operating Instruction
Add to my manuals22 Pages
Force FS Series: Your Reliable Garage Door Automation
The Force FS Series garage door operator offers smart features for convenient and secure operation of your sectional or up-and-over garage door. With its powerful motor and sturdy construction, it ensures smooth and reliable door movements.
- Automatic obstacle detection: The operator automatically reverses the door if it encounters an obstruction, preventing damage to your door and belongings.
advertisement
WARNING
Please read the manual carefully before you begin the installation and use. The installation of your new garage door operator must be performed by a competent expert or a specialist company. A competent person is, in accordance with EN 12635, considered a person who has appropriate training, qualified knowledge and practical experience in order to mount a door system properly and safely, and maintain.
The installation or repair without technical qualifications can cause serious injury, death and / or property damage.
25
CONTENTS
Important Safety Instructions...........……………………………....……………………………..27
Warranty Conditions.............................................................................................................30
Product Description & Features............................................................................................31
Pre-Installation Recommendations.......................................................................................32
Installation Instructions..........................................................................................................33
- Boom Rail Assembly
- Installation of Boom Rail and Operator
- Back-Up Battery installation (optional)
Programming Instructions....................................................................................................37
Connection of external control and accessories..................................................................40
Manual Disengagement.......................................................................................................42
Technical Specifications....………………………………………………………………….........43
Parts Listing……………………......…………….....................................................................45
Common Faults & Solutions.................................................................................................46
26
Dear Customer
Thank you for choosing a quality product from Force. Thanks to our unique quality management system, we continuously ensure that Force operators meet the highest standards of quality and comfort. Thank you for your confidence in purchase and we wish you much pleasure with your new Force garage door opener.
Declaration of Conformity (CE)
The FS and PLUS series garage door openers from Force meet the requirements of the applicable European and national guidelines. Compliance was demonstrated that corresponding declarations, certificates, test reports and documents have been obtained by the manufacturer and can be requested if required.
IMPORTANT SAFETY INSTRUCTIONS
1. Intended Use:
The garage door operator is designed exclusively for impulse operation of spring-balanced Sectional and
Up & Over garage doors doors in private / non-commercial operations. Door systems used in a public area have only one protective device, e.g. the force limiter, and may only be operated under supervision.
The garage door operator is designed for operation in dry rooms.
2. Unintended Use:
The garage door operator must not be used for purposes other than for the automation of garage doors.
Continuous operation and the use in the commercial sector is not permitted. The operator must not be used with doors without fall protection.
3. Qualification of the fitter and installer
Only correct fitting and maintenance by a competent / specialist company or a competent / qualified person in accordance with the instructions can ensure the safe and flawless operation of the assembly. A competent person is, in accordance with EN 12635, considered a person who has appropriate training, qualified knowledge and practical experience in order to mount a door system properly and safely, and maintain.
4. Safety instructions for installation, repair, maintenance and disassembly of the door system
DANGER!
Compensation springs are under high tension.
The adjusting or loosening the compensating springs can cause serious injuries! If necessary, maintenance and repair work should only be performed by an expert! Never attempt to replace, readjust, repair, or move the balancing spring for the counterbalancing of the door or their holders. Also inspect that the entire door system (pivots, door bearings, ropes, springs and fastenings) for wear and possible damage. Check them for signs of rust, corrosion and cracks. Error in the door system or misaligned doors can cause severe injury! Do not use the door system if repair or adjustment work needs to be done!
Mains Voltage
27
There is danger of electrocution upon contact with the mains voltage . Note, therefore, the following instructions: Electrical connections may only be performed by a qualified electrician. Electrical installation on site must comply with the relevant safety regulations (230/240 V AC, 50/60 Hz).
Disconnect the operator from the mains before performing any operator service
WARNING!
Non suitable fastening materials
Use of unsuitable fixing materials can result in the operator not being securely attached and can become loosened. The supplied mounting materials must be checked for their suitability for the intended installation location by the installer. Use the supplied mounting material (plugs) for concrete ≥ B15.
Fatal injury from hand rope
A guided type hand rope (pull cord) may lead to strangulation. Remove the pull rope/cord upon installing the operator.
Risk of injury from unintentional door movement
An improper installation or handling of the operator can trigger unwanted door travel and can result in people or objects being pinched. Follow all instructions contained in this manual. Any incorrectly mounted control devices (such as push buttons) can unintentionally trigger door travel resulting in persons or objects becoming pinched. Control devices must be mounted at a height of at least 1.5 m
(away from children). Assemble fixed control devices (such as push buttons) within sight of the door but away from moving parts.
Risk of injury due to unexpected door travel
Installation, maintenance, repair and dismantling of the operator and the garage door must be carried out by a specialist(s). Upon failure of the garage door operator, directly entrust an expert with the inspection or repair.
Safety advice for mounting
The specialist must ensure that, in carrying out the installation, the applicable regulations regarding occupational safety and those governing the operation of electrical equipment are complied with.
National guidelines must therefore be observed. Possible hazards, as defined in DIN EN 13241-1, are prevented by the design and installation according to our specifications. The garage ceiling must be designed so that a secure attachment of the opener system is ensured. Too high or too lightweight of ceiling material, the opener system must be attached to additional safety/security braces.
CAUTION!
Crushing Risk by Boom Rail Mounting
When assembling the boom rail, there is a danger that fingers can be caught. Take care not to get your fingers caught between the profile ends.
Pinching Risk in the Boom Rail
Grasping with fingers into the boom rail while the door is moving may cause pinching. Grasp only when the door is not moving on the boom rail.
5.Safety information for commissioning and operation
CAUTION!
Pinching Risk in the Boom Rail
Grasping with fingers into the boom rail while the door is moving may cause pinching. Grasp only when the door is not moving on the boom rail.
Risk of injury by pull cord
If you hang from the cord knob, the door can crash down and you can get hurt. The operator could become dislodged and injure people underneath, damage or even destroy objects. Do not hang from the pull cord.
28
WARNING!
Risk of injury by rapidly closing door
If the pull cord knob is pulled while the door is open, there is a risk that the door could close quickly because of weak, broken or defective springs or due to faulty counterbalance mechanism. The pull cord should only be pulled while the door is closed.
Risk of injury during door movement
While the door is moving, the risk of injury or damage to persons or objects is increased while standing in the movement area of the door. Make sure that no children are playing with the door operator system.
Ensure that when the door is moving that no persons or objects are located within the door movement area. Only use the garage door operator when you have view of the garage door it self and can monitor its movement. Monitor the door travel until the door has reached the end position. Drive or pass through the garage door entryway ONLY when the door has come to a standstill! Never stand directly under the open door.
Proper Use
Demonstrate to all persons using the door operator system the proper and safe operation of the garage door operator. Demonstrate and test the mechanical release as well as the safety return.
6. Precautions for the use of the remote control
WARNING!
Risk of injury from unwanted or accidental door movement
Accidental pressing of a button on the remote control can lead to unwanted door movements and injure someone. Make sure that remote controls are not accessible to children and are only used by persons who have been instructed in the operation of the remote-controlled garage door operator system! Only use the remote when you are in visual contact with the door unless a safety device is connected ( e.g. photocells). Drive or pass through the garage door entryway ONLY when the door has come to a standstill! Never stand directly under the open door. Note that the accidentally pressing a key on the remote (for example in your pocket / handbag) may lead to an unwanted door travel.
7. Safety Installations
Safety-related functions and components such as automatic power shutdown and the use of external photocells have been tested and meet the requirements of EN 12453 and EN 12445 standards.
WARNING!
Risk of injury from malfunctioning safety devices
To test the safety reverse, with both hands, hold the door as it closes. The garage door operator system must stop and initiate the safety reverse. Test this also as the garage door opens. The door system must switch off and stop the door. Upon failure of the security reverse, directly entrust an expert with the inspection or repair.
8. Inspection and maintenance
The garage door operator is maintenance-free. According to the manufacturer and for your own safety, we recommend that you allow the garage door operator system to be inspected by an expert. A check or a necessary repair should only be performed by a specialist. Please also contact your supplier. A visual inspection may be carried out by the user. Check all safety and security features on a monthly basis.
Existing errors or defects must be rectified immediately. Inspect the tension of toothed belt every six months and adjust accordingly if necessary. During the opening and closing phase, the belt may loll briefly because of rail profile. However, this effect does not have any technical losses and also does not adversely affect the function and life of the belt.
29
WARRANTY CONDITIONS
Warranty
We are exempt from the warranty and product liability if the unit has been modified without our prior consent or improper installations are performed or initiated against our assembly instructions.
Furthermore, we assume no responsibility for the inadvertent or negligent operation of the operator, as well as for the improper maintenance of the operator and accessories, nor for the improper maintenance of the door and its counterbalance mechanism. Batteries, light bulbs, and LEDs are also excluded from the warranty claims.
Duration of Warranty
In addition to the legal guarantee of the dealer from the purchase contract, we provide the following warranty from date of purchase:
• 3 Years
• 2 Years on radio and accessories
The warranty time is not extended upon using the warranty. For replacement deliveries and rectification work, the warranty period is six months or at least the remainder of the warranty period.
Conditions
The warranty applies only to the country where the product was purchased. The product must have been purchased through our authorized distribution channels. The warranty only covers damage to the contractual item itself. Reimbursement of expenditure for dismantling and installation, testing of corresponding parts, as well as demands for lost profits and damages are excluded from the guarantee.
The receipt of purchase serves as proof of warranty.
Performance
For the duration of the warranty, we shall resolve any defects of the product which are demonstrably attributable to a material or manufacturing defect. At our discretion, we shall, free of charge, replace the defective product for a non-defective, repair or refund a diminished value. Excluded are damages caused by:
• Improper installation and connection
•
Improper commissioning and operation
• External influences such as fire, water, abnormal weather conditions
•
Mechanical damage due to accidents, dropping or shock
• Negligent or deliberate destruction
• Normal wear and tear or poor maintenance
•
Repair by unqualified persons
• Use of non-original parts
•
Removal or obscuring of the serial number
• Replaced parts become property of the manufacturer
30
PRODUCT DESCRIPTION & FEATURES
1. Automatic safety reverse
Automatic stop / automatic reverse are controlled by the software on our circuit boards. We are cautious to protect your children, pets and property.
2. Soft start / Soft stop
Ramping speed up and down at the start and end of each cycle reduces stress on the door and opener, and makes for longer life and quieter operation.
3. Auto-Close
Auto-Close ensures peace of mind and keeps your house secure by automatically closing the door upon entering or exiting the garage.
4. Self learning - open and close obstruction force
The amount of opener power for different stages of the door’s travel is learned during setup and is constantly re-profiled. Opener force measurement is automatically adjusted to a suitable range.
5. Simple adjustment of the end positions
Setting the end positions is easily done by pressing a button on the display panel.
6. Terminals for Accessories
Terminals are available for photocells (safety beam) extra receivers, wired or wireless wall switches, caution/warning lights and more.
7. Energy saving LED
The courtesy LED light has a 3 minute delay, switching on with each cycle to illuminate your darkened garage.
8. Battery backup available
Our openers can be connected with our battery backup in the event of power failure at your home.
9. Self-Lock in gear motors
Force gear motors will self-lock with our disengagement systems.
10. Manual release
Don't worry about power failure, the manual release system is a solution for operation the door at any time.
11. Transmitter technology
Rolling Code technology (7.38 x 1019 Combinations), 433.92Mhz frequency, 4 channel remote control design ensures that you can control 4 different motors with one transmitter.
12. Lower headroom
With as little as 30mm required between the ceiling and the highest point of the door travel, the opener can be flush mounted for low headroom applications.
13. Metal bottom plate, stronger and more secure
14. Open/Stop/Close - button (A)
Front panel open / stop / close buttons for operation. (see below)
15. External mains power fuse (B) (see below)
B
A
31
PRE-INSTALLATION RECOMMENDATIONS
1. Check the garage door and garage door system
DANGER!
Balancing springs are under high tension. The readjustment or loosening of the balancing springs can cause serious injuries! For your own safety, necessary maintenance and repair work should of the balancing springs should only be performed by an expert.
Never attempt to replace, readjust, repair,or move the balancing springs for the counterbalancing of the door or their holders. Check the entire door system (pivots, door bearings, ropes, springs and fastenings) for wear and possible damage. Check them for signs of rust, corrosion and cracks. Error in the door system or misaligned doors can cause severe injury! Do not use the door system if repair or adjustment work needs to be done!
The construction of the operator is not designed to operate sluggish doors, i.e. doors that can no longer or hardly be opened or closed manually. The door must be in a mechanically healthy state that is easy to operate by hand (EN12604).
Open the garage door approximately half way and let go.
The door should maintain this position and move neither up nor down. If the door moves in either direction, then there is the risk that either the balancing springs/weights are not properly adjusted or defective. In this case, increased wear and malfunctioning of the door is expected. Check that the door can open and close correctly.
Disengage/Remove any mechanical locks that may be on the
door -- they are not needed with the use of the garage door operator. These include in particular the locking mechanisms connected with the door. For installation and commissioning, check the illustrated section. Take note of the text in the appropriate sections.
2. Required Clearance
The clearance between the highest point of the door travel and the ceiling must be at least 30 mm. For a lower clearance height, and if space is available, the operator can be mounted behind the opened door.
In these cases, an extended door link must be used and may be purchased separately. The necessary electrical outlet for the electrical connection should be mounted within approx. 50 cm from the operator
(refer to the electrical mains chapter).
Check these dimensions!
Figure 1
32
Important note: As an additional safety device, the use of a photocell (safety beam) is recommended
(sold separately).
3.
Emergency release
F or garages without a second entrance, an emergency release for the mechanical release is necessary to prevent getting locked in the garage in the event of power failure. The emergency release is doorspecific and must be ordered separately.
Check the function of the emergency release monthly.
INSTALLATION INSTRUCTIONS
Steel
Boom Rail Assembly
2 Part
Boom Rail
A:1500 mm
B:1500 mm
Sleeve
Figure 2
3 Part
Boom Rail
C:1000 mm
D:1000 mm
Sleeve
Sleeve
E:1000 mm
Figure 3
1.
2-Part Rail
As in Figure 2, slide piece A into the sleeve, then slide piece B into the sleeve.
3-Part Rail
As in Figure 3, slide piece C into the first sleeve, followed by piece D. Then slide piece D and E into the second sleeve
2. Cut the plastic thread; pull the screw rod along with inner belt to the end rail position (Figure 4).
3. Now run the spring and nut on the threaded rod as shown in Figure 5.
4. Tighten the nut to the proper position as shown in Figure 6. Remove the protective film and cut the last cable ties on the sprocket -- the boom rail assembly is now complete.
33
F
F
Figure 4
Figure 5
Figure 6
Mount Wall Bracket and Door Bracket
Wall Bracket – Close the garage door and measure the garage door width at the top and mark the center. Locate and mount the wall bracket 2 cm - 15 cm above the door on the inside wall.
(Depending on the actual installation space).
Door Bracket – Attach the door bracket to a structural part of the door as close to the top edge as possible.
Figure 7
34
Installation of boom rail and operator
Figure 8
STEP 1 (Figure 8)
Attach the operator to the boom rail. Assemble the 2 “U” hanging brackets with 6mm nuts supplied.
STEP 2 (Figure 8)
Place the boom rail and operator assembly centrally on the garage floor with the operator opposite the garage door. Lift the front of the rail up to the door bracket. Insert the pivot pin and secure it with the split pin supplied.
STEP 3 (Figure 8 and 9)
Lift and support the operator (with a ladder) so it is positioned centrally and level. Attach the operator and boom rail to the ceiling via the iron brackets A & B.
WARNING: Do not allow children around the door, opener or supporting ladder -- serious injury and/or damage may result from failure to follow this warning.
Figure 9
STEP 4 (Figure 8 and 10)
Attach the shuttle to the rail with the 4 6x23 screws, then slide the shuttle towards the closed garage door. Attach the straight arm and bent arm pieces. Position and bolt the arms to the top edge of the door using the bolts supplied.
STEP 5
Lift the garage door until the shuttle locks into the drive chain/belt.
The operator is now ready to be programmed.
Figure 10
35
Backup Battery Assembly (optional/not in EU)
STEP 1 (Figure 11)
Assemble the battery & battery bracket as in the picture; attach with screws supplied.
STEP 2 (Figure 12)
Connect the battery to opener.
Figure 11 Figure 12
36
PROGRAMMING INSTRUCTIONS
1. Programming Opening and Closing Limits
a) Press and hold SET Button until 1 appears on the display, then release the button.
The door opener is now in Programming Mode.
b) Press and hold the
UP until the door reaches the desired open position.
NOTE: Fine adjustments can be made by toggling the UP & DOWN buttons c) Now press the SET button to confirm the position. The display will now indicate the number 2. d) Next press and hold the DOWN button until the door reaches the desired close position. For fine adjustments toggle the UP & DOWN buttons.
e) Now press the SET button to confirm the close position.
CAUTION: The door will now cycle the open and close phases to set the travel limits and force sensitivity adjustments. The door is now set for normal operation.
2. Programming Remote Controls
NOTE: The remote controls that are supplied with the garage door opener are pre-programmed. a) Press the CODE button. A dot (.) will be indicated in the corner of the display.
b) Now press the button on the remote you want to use, wait 2 seconds, then press and hold the same button on the remote again for 2 seconds.
The dot ( .) on the display will flash to confirm the code, then turn off. Repeat the process for additional remotes that need to be stored.
3. Deleting Stored Remote Controls
Press and hold CODE button until a C is indicated on the display. All stored remotes will be deleted.
37
Increase Force
Decrease Force
4. Obstruction Force Adjustment (Menu option 3 in display)
CAUTION: the obstruction force adjustment is set automatically during programming.
Normally, no adjustment is necessary.
The factory-set forces (value 3) are designed to provide a smooth operation of the opener with this standard garage doors; the factory setting forces should, in principle, be sufficient to fully open and close the garage door.
The factory setting of the operator complies with the legal or relevant standards (such as the EN 13241-1, EN 12453, EN 60335-2-95) established requirements for operational forces, and thus the maximum allowable power limits.
The operating force of the operator may be increased or decreased (values 1 -9), if necessary, by the following procedure below.
NOTE
This must be done when, for example, the end-stop point of the garage door during the opening or closing phase via the factory setting (value 3) is not met; the setting for the force output can be increased (as described below) so that the the respective end-point is reached.
In addition, during the operational period of the garage door, the operational optimality may deteriorate (e.g. slackening of tension springs). Therefore, for safety reasons, adjusting force of the operator on an unsound garage door could result in a malfunctioning door, thus increasing the risk of personal injury or property damage -- this risk is especially increased when activating the manual release of the garage door from the operator.
DANGER
Deviating/Increasing the factory force setting (value 3) can lead to serious personal injury, up to the danger of life as well as property damage! Altering the factory force setting increases the pressure exerted by the operator when opening and closing the garage door, thus increasing the force that the garage door exerts in each respective phase. When changing or differing from the factory settings, the risk of severe injury to persons up to the danger of life as well as the risk of damage to property is increased - for example, by pinching or squeezing persons or things near the garage door. Differing from the factory settings, increasing the power setting to exceed the aforementioned maximum allowable limit can cause power limitations. Therefore:
NOTE:
Adjusting the factory force setting (value 3) to an alternate value (value 1-9) must be ensured to be compliant with the legal requirements and relevant standards of force limitations by a competent person. Inspections must be performed and documented to the described risk of injury and exclude life and property.
a) Press and hold the SET button until 3 appears on the display, then release the button.
The unit is now in force adjustment mode.
b) Press the
UP button to increase the force setting or the DOWN button to decrease the force setting. The maximum force is 9 and the minimum is 1.
c) Press SET to confirm your setting
NOTE: The factory force setting is 3.
38
Auto Close enabled
Auto Close disabled
Inease A/C time
Decrease A/C time
5. Automatic Closing
NOTE: We recommend that Photocells (Safety Beam) be used in any installation setup where the Auto-Close function is enabled.
a) Press and hold the UP button until a horizontal bar is indicated on the display. Now press UP button once to set the auto-close time (in minutes).
b) Press the UP button to increase the time, or the DOWN button to decrease the time.
The Maximum time is 9 minutes. To disable Auto
Close, set time to zero (0).
c) Press SET button to confirm the your selected time.
Photocell disab led
Photocell enabled
6. Photocells (safety beam)
NOTE: Make sure the photocell has been correctly installed and uses
Normally Closed contacts to the accessory terminals of the opener
(Figures 13 & 14)
Also note that the photocell function must be disabled if NO photo beams are fitted, otherwise the door cannot be closed, and the LED will blink once time as an indication.
a) Press and hold the DOWN button until 11 appears on the display. To enable the photocell option, press UP again, the display will indicate an H (enabled) or press DOWN button to disable photocells ( 11 will be displayed).
b) Press SET to confirm your choice.
7. Open / Stop / Close Terminals
The O/S/C facility can be used for an external push button switch to operate the opener. The switch must have voltage free
normally open contacts (Figure 16)
39
Photo
cell connection (optional) – Figure 13, Figure 14
Switch control connection (optional)
– Fig ure 13
Figure 13
Figure 14
Other terminal introduction and application
1.
The O/S/C interfaces available. (Figure 16)
Add a new O/S/C button to open or close the door (e.g. interior push-buttons).
2.
Flashing light function. (Figures 15 and 16)
There are corresponding interfaces for this function and provide 24v-35v flashing light voltage. Connect the flashing light with DC 24v-28v, current≤100mA. When using AC 220V power flashing lights, please fit an adapter and wiring as required.
3.
Pass door (SD) protection (Figure16)
This function ensures that the door can’t be opened unless the small pass door is closed. The door panel won’t be damaged.
40
Figure 15
Figure 16
41
MANUAL DISENGAGEMENT
Attach warning label
Attach the warning about the risk of entrapment in a permanently prominent, clean place. For example, near the permanently installed buttons used to open and close the garage door opener.
The opener is equipped with a manual release cord to disengage the shuttle and enable moving the door by hand while holding the handle down (Figure 17). Pull on the handle to disengage the shuttle. To re-engage the door simply run opener in automatic mode or move door by hand until the trolley engages in the chain shuttle.
In situations that a pedestrian door is not installed or available (2nd entrance to garage), it is recommended that an external disengagement device should be fitted (not supplied)
(Figure 18).
Figure 17 Figure 18
42
TECHNICAL SPECIFICATIONS
Input voltage
Max. pull force
Max. door area
Max. door weight (Balanced)
Max. door height
Drive
Opening / Closing Speed
Drive mechanism
L.E.D
Limit setting
Transformer
Radio frequency
Coding Format
Standard transmitter
Code Storage Capacity
Caution light terminal
Working temperature
Safety Protection
Protection level
FS 600
600 N
FS 1000
220 - 240V / 110 - 127V, 50–60 Hz
1000 N
FS 1200
1200 N
10.0
㎡
80 kg
2400 - 3500mm
Chain / Belt
160mm / Second
15.0
㎡
100 kg
2400 - 3500mm
Chain / Belt
160mm / Second
18.0
㎡
140kg
2400 - 3500mm
Chain / Belt
140mm / Second
Chain / Belt Chain / Belt
24V / 15pcs LED bulbs
Chain / Belt
Electronic Electronic
Overload protection technology
Electronic
433.92 Mhz 433.92 Mhz 433.92 Mhz
Rolling code (7.38 x 10
19
Combinations)
2 X 2 X
20 different codes
2 X
Included
-40℃ - +50℃
Included
-40℃ - +50℃
Included
-40℃ - +50℃
Soft start & Soft stop, photo cell option, caution light option
IP20 IP20 IP20
FS 600 FS 1000
FS 1200
43
Input voltage
Max. pull force
Max. door area
Max. door weight (Balanced)
Max. door height
Drive
Opening / Closing Speed
Drive mechanism
L.E.D
Limit setting
Transformer
Radio frequency
Coding Format
Standard transmitter
Code Storage Capacity
Caution light terminal
Working temperature
Safety Protection
Protection level
FS 600-Speed
FS 600-Speed FS 1000-Speed
220 - 240V / 110 - 127V, 50–60 Hz
600 N 1000 N
10.0
㎡
80 kg
2400 - 3500mm
15.0
㎡
100 kg
2400 - 3500mm
Chain / Belt
200mm / Second
Chain / Belt
Chain / Belt
200mm / Second
Chain / Belt
24V / 15pcs LED bulbs
Electronic Electronic
Overload protection technology
433.92 Mhz 433.92 Mhz
Rolling code (7.38 x 10
19
Combinations)
2 X 2 X
Included
-40℃ - +50℃
20 different codes
Included
-40℃ - +50℃
Soft start & Soft stop, photo cell option, caution light option
IP20 IP20
FS 1000-Speed
44
22
21
20
19
18
PARTS LISTING
17
23
24
25
27
26
32
33
30
28
29
6
8
9
3
16
15
14
13
12
11
10
5
7
2
4
34
1
31
7
8
9
4
5
6
10
11
12
Item Qty
1
2
3
1
1
1
1
1
1
1
1
1
1
1
1
Description
Control Panel Cover
Opener Middle Cover
LED light Cover
PCB (1)
PCB (2)
DC Gear Motor
Motor Shaft Sleeve
Transformer
Transformer Plate
Steel Bottom Base
Reference Switch
Sprocket Support
20
21
22
23
24
15
16
17
Item Qty
13 1
14 1
18
19
1
1
2
1
2
1
1
1
1
1
Description
Switch Cover
C Rail - Steel
U Hanging Bracket
Easy Click Bracket
Mounting Bracket
Chain or Belt
Idler Pulley
Wheel Bracket
Track Ending Bracket
Wall Bracket
Door Bracket
Bent Arm
30
31
32
33
34
27
28
29
Item Qty
25 1
26 1
1
1
1
1
1
2
1
1
Description
Straight Arm
Trolley Assy - Bottom
Trolley Assy - Top
Trolley Arm
Release Cord
Caution Card
Release Handle
Remote Control
Remote Control Holder
Wire Connection
45
COMMON FAULTS & SOLUTIONS
Fault appearance
Nothing working on opener
Opener not working,
Display shows
Door moves up only.
Will not move down; display shows
Fault cause
1.
Power supply
2.
Plug wire is loose
Faulty learning on “Up” or “Down” limit travelling
Photocell function has been activated, but without connecting any photo cell device.
Solutions
1.
Check the power supply from electronic plug on opener.
2.
Carefully open the opener cover, check all plug wires on control boards.
Redo system opening and closing limits. See Section 1 under Programming Instructions.
Turn off the photo cell function if photo cell device not connected. See Section 6 under
Programming Instructions.
Up and Down moving is reversed
Door was automatically reversed
15-40 cm before the door closed completely
Remote is not working
Cannot code in new remotes
Reversed plug wire between gear motor and motherboard
Automatic Safety Return. Due to an old and improperly adjusted garage door.
Unbalanced, weak, or defective springs.
※ Firstly, disconnect power supply, then open the cover and reverse the plug wire between gear motor and board. Rerun system opening and closing limits.
1. Check the door springs in all door positions.
2. Re-set the system open/close limits
3. Increase the force setting for automatic reverse.
1.
Dead battery
2.
Antenna is loose or not well extended
3.
Interference between remote/receiver
1.
Maximum stored remotes reached
2.
New remote is not compatible with opener
1.
Replace battery
2.
Extend the antenna on the opener
3.
Get rid of interference
1.
Press “code” button over 8 Sec until LED displays “C”.
All stored codes deleted, code in new remotes again.
2. Use only Force approved remotes
Display shows
Opener does not work.
Display shows after opener has only moved a few centimeters
1. Loose gear motor plug wire
2. Damage to gear motor
3. Damage to control board
1. Hall sensor wire plug has loosed between hall sensor and board.
2. Hall sensor or board is damaged
1. Re-insert plug wire on gear motor
※
2. Replace new gear motor
※
3. Replace new control board
1. Check the wire plug
※
2. Check the hall sensor
※
3. Replace control board
NOTE: In accordance with EN 12635, solutions marked with ※ are only to be performed by a competent/
qualified person.
46
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Important Safety Instructions
- 6 Warranty Conditions
- 7 Product Description & Features
- 8 Pre-Installation Recommendations
- 9 Installation Instructions
- 13 Programming Instructions
- 16 Connection of external control and accessories
- 18 Manual Disengagement
- 19 Technical Specifications
- 21 Parts Listing
- 22 Common Faults & Solutions