MODUL-R™ MR-2608 FIRE ALARM CONTROL UNIT GENERAL DESCRIPTION FEATURES The MR-2608 is a microprocessor based fire alarm control unit with 8 zones for conventional fire detection devices. • UL, ULC, CSFM, and MEA Listed • 5 year warranty • Conventional input circuits 8-Style B (Class B) or 4-Style D (Class A) Front Panel • Input circuits programmable for N.O. or N.C. contacts The front panel consists of 4 system LEDs, 8x2 zone LEDs, and 6 function keys. The four system LEDs provide common indication of alarm, trouble, supervisory, and AC power. LEDs will flash with a new condition and will remain on steady after acknowledgement. The zone LEDs consist of a red alarm LED and a yellow trouble LED for each input circuit. LEDs will flash with a new condition and will remain on steady after acknowledgement. Amber alarm LEDs are available by special order for use with supervisory zones. • Style Y (Class B) notification appliance (bell) circuits • System alarm and trouble relays • Alarm and trouble LEDs for each zone • Custom labels per zone • Alarm verification by zone • Ground fault indication by input circuit • Programmable input circuits Function keys provide the following functions : acknowledge, signal silence, system reset, ground fault, lamp test, and city disconnect. Each function key has an LED to indicate when it is available. • Two stage alarm capability The yellow zone LEDs are also used to indicate common troubles. This function is activated by pressing the Ground Fault function key. • Optional remote annunciator • Field programmable via service terminal • 'Hot Key' system controls • Signal silence inhibit Input Circuits • Signal time limit cut-out Input circuits are individually software definable for contact devices only, smoke detectors only, or combination of smoke detectors and contact devices. Circuits defined for smoke detector and contact devices are able to differentiate between smoke detector operation and contact device operation which permits combining contact and smoke detectors on one common circuit when the alarm verification feature is used. The circuits are further definable for alarm or supervisory. If there are any supervisory zones defined, the function relay becomes the supervisory relay. Input circuits programmed for contact devices can be further defined for use with N.O. or N.C. contacts. Circuits can support Style B (Class B) or Style D (Class A) wiring. When Style D wiring is used, two circuits are required for each Style D circuit. Ground fault conditions occurring on the input circuits are indicated as to the circuit of origin of the ground fault. MODUL-R • Totally software driven MR-2608 Output Circuits The MR-2608 provides 2 supervised polarity reversing notification appliance (bell) circuits, 1 general purpose Form C relay, and 2 system operated Form C relays for alarm and trouble indication. Ground faults are indicated by notification appliance (bell) circuit. The general purpose Form C relay operation is program defined. If there are any supervisory type input circuits, the general purpose relay becomes the supervisory relay. The system Form C relays are for alarm and trouble indication. The trouble relay is normally energized to allow for indication of both AC power and battery power loss. Fire Alarm Control Unit MODUL-R™ FIRE ALARM CONTROL UNIT MR-2608 TECHNICAL DATA 120VAC, 60Hz or 220VAC, 50Hz INPUT POWER INPUT CIRCUITS (8) Voltage Supervisory current Contact devices Smoke detectors Alarm current Contact devices Smoke detectors Max. no. of devices Compatible devices End-of-line device Contact circuit Smoke detectors Total line resistance Total line capacitance Maximum line length 20-28VDC BATTERY 10mA 10mA ANNUNCIATOR 10mA 80mA 30 (smoke detectors) MR series BELL 1 BELL 2 470 Ω resistor 3.9kΩ resistor 60Ω 100µf 3,050m (10,000ft) (18AWG) NOTIFICATION APPLIANCE (BELL) CIRCUITS (2) Supervisory current Alarm current Voltage End-of-line device 1.0mA 2.0A, 3.0A total for unit 24VDC (unfiltered) 10kΩ resistor SYSTEM RELAYS (2) Alarm, trouble 0.5A @ 120VAC GENERAL PURPOSE RELAY (1) 0.6A @ 120VAC BATTERY CAPACITY 4.0Ah + + TXD RXD + + - ORDERING INFORMATION Model Description BASIC CONTROL UNIT PACKAGE MR-2608 Conventional control unit, 8 circuit ACCESSORIES COM AUX. RELAY N.O. N.C. MR-220-4VAC MR-2614 MR-2614S COM N.O. N.C. CHASSIS GND COM TROUBLE N.C. N.O. + ZONE 1 + ZONE 2 + ZONE 3 + ZONE 4 + ZONE 5 + ZONE 6 + ZONE 7 + ZONE 8 ALARM MR-2613 MRD-MP300 MRD-EOL-470 MRD-EOL-3k9 MRD-EOL-10k MR-2995 MR-2608FT Terminal Strip 220VAC, 50Hz option Remote annunciator board Remote annunciator c/w board Remote trouble buzzer Plate for end-of-line resistor for contact circuits and notification appliance (bell) circuits 470Ω end-of-line resistor for contact circuits 3.9kΩ end-of-line resistor for smoke detector circuits 10kΩ end-of-line resistor for notification appliance (bell) circuits 4Ah battery pack Flush trim DIMENSIONS Back box : Outer door : 30.48W x 26.67H x 9.84Dcm (12 x 10.5 x 3.875in) 32.70W x 27.31H x 1.27Dcm (12.875 x 10.75 x 0.5in) Distributor: Secutron Inc. Electronic Protection Systems 70 Esna Park Drive, Unit 14 Markham, Ontario, Canada L3R 6E7 MODUL-R Tel: (905) 470-4070 Fax: (905) 470-2880 Toll Free: 1-800-387-8058 E-mail: inquiry@secutron.ca www.secutron.ca MR-2608 One River Place 1225 East River Drive, Suite 210 Davenport, IA 52803 Phone: 1-888-673-2900 Fax: (319) 322-0497 Fire Alarm MODUL-R™ is a trademark of Secutron Inc. ® A DSC Company Control Document #10-204 Unit Release 2.0 - 07/99 ©1999 Printed in Canada
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising