Security description
Before using the strobe light, you must open the cover, remove the black EPE, to prevent the high voltage burning the EPE.
1.
Please read all instructions in detail.
2.
Please keep this manual well.
3.
Please follow all cautions or warnings and instructions for this product.
4.
Do not connect this product to power supply when clean the lighting equipment.
5.
Do not put the lighting equipment near the water sources.
6.
The slots and opens on the bottom of the cover are used for ventilation of the machine body to ensure the lighting equipment to work in effectiveness and prevent overheat of the machine these slots and opens must be cleaned at regular intervals.
7.
Do not insert the irrelevant articles through slots and opens into the machine body to avoid that the articles will touch the high voltage components and lead to short circuit in the components and lead to short circuit in the components and fire or electronic attack maybe happened.
8.
Do not repair or maintain this equipment yourself because of the high voltage or other dangers after opening the cover the qualified maintenance technician shall be checked. For whole and full maintenance. www.flash-butrym.pl
2
FL-1500SC DMX
Function and Operation
DMX512 connecting:
Controller contain DMX512 signal output standard use input output (3 pin XLR connector) to connect controller and light. Make sure the control cable output pins were corresponding to the XLR connector of the light, 1 for GND 2 for- 3 for +. Otherwise, exchange 2pin and
3pin. Connect cable length less then 100m, or will be interfered by other machines.
1. Address code setting:
The light should controlled by DMX512 signal All lights of this kind needs a data start address code for the purpose of the one signal controls the corresponding light. The data start address code also names section number. Light operate by controller sending out the data. The light use 3 channel sections.
Channel 1: Dimmer
Channel 2: Flash Speed
Channel 3: Value 0-128 Auto mode
Value 129-255 Sound mode
Function Setup
FUNCTION
Auto Mode
Sound Mode
DMX512 Control
ADDRESS ON
9, 10
10
1
No Slave LIGHT
Specifications
1. Voltage: AC 220V +/- 10%; 50-60Hz
2. Power: 1500W
3. Fuse: 20A
4. DMX512 channel: 3ch
5. Net. Weight: 4kg
6. Gross Weight: 5kg
7. Size: 540x300x205mm
ADDRESS OFF
1,2,3,4,5,6,7,8
1,2,3,4,5,6,7,8,9
2,3,4,5,6,7,8,9,10
1,2,3,4,5,6,7,8,9,10 www.flash-butrym.pl