EFXP Series - Emergi-Lite
EFXPW= Wall Bracket Mount
TYPE:
CATALOG #:
NOTES:
INDUSTRIAL
EFXP Series
Explosion-Proof Remote Exit Signs
Standard Features
• Available with 6, 12 and 24 volt lamps for DC operation or 120 volt
AC fixtures
• Exits shown are explosion-proof fixtures of heavy cast aluminum
construction with Pyrex® lenses. Exit housing is an 18 gauge
fabricated steel box with a baked enamel finish. Stenciled exit
lettering is available on one or two faces. All EFXP Series have extra
large downlight openings
• EFXP units are designed for mounting in locations that are remote
from the power source. If the power source is installed outside
hazardous areas, the length of the connection wires should be
carefully considered to ensure that the voltage of the emergency
power unit and the wire size of the connecting circuit are adequate
to offset the voltage drop in the circuit
• Sealed test switch
• Complies with NEC, OSHA and NEMA specifications for the
following Classes and Groups:
Class I, Division 1 & 2, Groups C & D (300W PS-25 max)
Class II, Division 1 & 2, Groups E, F & G (60W max)
Class III, Division 1 & 2 (150W max)
UL924 Listed for use in Paint Spray Areas (75W max)
Suitable for Wet Locations
• 3-year limited warranty
Detailed warranty terms located at: www.emergi-lite.com/usa/files/EL_Warranty.pdf
EFXPP= Adjustable Pendant
Mount
EFXPC= Ceiling Mount
Dimensions
Dimensions are approximate and subject to change.
AC-Only and AC/DC Exit Signs
6”
6”cm]
[15.24
9-1/8”
9-1/8”
23.17
cm]
16-7/8”
16-7/8”
[42.86
cm]
17-3/4”
17-3/4”
[45.08
cm]
Pyrex® is a registered trademark of Corning Glass.
Output Voltage: Must be
identical to DC Input Voltage
23-3/8”
[59.2 cm]
30-5/8”
[77.8 cm]
30-5/8”
23-3/4”
Lamp Selection
Lamp Type
Unit Warranty*
Entire unit (excluding lamps) carries a 3-year Full Warranty.
Quartz Bi-Pin
*Subject to proper installation and maintenance.
Medium Base
Power Consumption Chart
120/277VAC, 60Hz maximum 0.3/0.15A
LED Lamp, Red
How to Order
SERIES
20-1/8”
[51.0 cm]
23-3/4” [60.4 cm]
Wattage: Panel oversized 10-20%
greater than total connected load.
EFXP= Exit series
23-3/8”
To Lighting Loads
AC - Normal Operation
DC - Emergency Operation
20-1/8”
TS Transfer Panel
Output
Input Voltage:
From AC - 120 Volt, 60Hz, 1 phase
(other voltages available).
From DC - 6, 12, 24 or 120 Volt (select).
16-7/8”
16-7/8”
[42.86
cm]
Combination Units
23-3/4”
Electrical Specifications
for Transfer Panel
Self-Powered Exit Sign
DC Output
34-1/8”
34-1/8”
[86.67
cm]
17”
17”
[43.18
cm]
Emergency
Lighting Unit
AC Input
assigned
to same
breaker
and/or
phase
23-3/4” [60.4 cm]
The transfer circuit is not designed for
use in hazardous or explosive areas.
The transfer circuit is to be mounted
remotely from hazardous areas.
6”
6”cm]
[15.24
12-3/8”
12-3/8”
[31.43
cm]
12-3/8”
12-3/8”
[31.43
cm]
Mounting
Pendant Mount
Wall Mount
Ceiling Mount
5-3/4”
5-3/4”
[14.6
cm]
MOUTING
C= Ceiling mount
P= Pendant
W= Wall
Voltage
Lamp Type
Suffix
6V
15W
JC-6V15W
2,000
XX6
25W
25A-12
1,000
XX12
24V
25W
143A
1,000
XX24
120V
25W
A19
2,500
AC/20
120V
5W
–
100,000
XX120
# OF FACES
AC120= 120V-25W (AC only)
XX120= 120V-5W LED
Average Life
(hours)
12V
LAMP TYPE
XX6= 6V-15W (DC only)
XX12= 12V-25W (DC only)
XX24= 24V-25W (DC only)
Power
1= Single face
2= Double face
3= Triple face
LETTERS
-R= Red
-G= Green
Example: EFXPC(XX6)-2R
AC VOLTAGE
120= 120VAC
277= 277VAC
DC VOLTAGE
-6= 6VDC
-12= 12VDC
-24= 24VDC
SERIES
-TS= Transfer circuit
LOAD WATTAGE
-25= 25W
-50= 50W
-75= 75W
-100= 100W
Example: 120-6-TS-25
All information and specifications contained in this specsheet are subject to change due to engineer design, errors and omissions.
Illustrations and diagrams within this specsheet may vary from actual products. 2016© Thomas & Betts Limited. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising