Installation Guide Guía de Instalación Guide d`installataion

Installation Guide Guía de Instalación Guide d`installataion
INS10492 - 9/15
Installation Guide
Guía de Instalación
Guide d’installataion
HELPFUL TOOLS
For safety and ease of faucet replacement, Moen
recommends the use of these helpful tools.
HERRAMIENTAS ÚTILES
Para que el cambio de la llave sea fácil y seguro, Moen
le recomienda usar estas útiles herramientas.
OUTILS UTILES
Par mesure de sécurité et pour faciliter l’installation,
Moen suggère l’utilisation des outils suivants.
SERVICE UPDATER KIT
Service Kit 169032
SERVICE UPDATER KIT
Service Kit 169032
SERVICE UPDATER KIT
Service Kit 169032
1
2
3
Remove data cable and power cable from Control Box.
Insert data cable and power cable into Service Update Kit.
Plug Service Update Kit cable into power port of Control Box.
Remove data cable and power cable from Control Box.
Insert data cable and power cable into Service Update Kit.
Plug Service Update Kit cable into power port of Control Box.
Remove data cable and power cable from Control Box.
Insert data cable and power cable into Service Update Kit.
Plug Service Update Kit cable into power port of Control Box.
4
Programming will start automatically. Green & red LEDs will
blink for 20 seconds indicating programming in process.
Do not disconnect any of the connections while
programming is in process.
5
0
45
30
15
Sec.
Programming will start automatically. Green & red LEDs will
blink for 20 seconds indicating programming in process.
Do not disconnect any of the connections while
programming is in process.
Programming will start automatically. Green & red LEDs will
blink for 20 seconds indicating programming in process.
Do not disconnect any of the connections while
programming is in process.
Once Green & Red LEDs turn solid, the programming is
complete.
Once Green & Red LEDs turn solid, the programming is
complete.
Once Green & Red LEDs turn solid, the programming is
complete.
INS10492 - 9/15
6
7
Faucet will go through the normal start up process.
Make sure there are no objects or people within 3 feet
of the faucet during the start up process.
1
1 1
2
1.
2.
1.
2.
1.
2.
2
Disconnect the cables from Service Update Kit.
Disconnect Service Update Kit from Control Box.
Disconnect the cables from Service Update Kit.
Disconnect Service Update Kit from Control Box.
Disconnect the cables from Service Update Kit.
Disconnect Service Update Kit from Control Box.
1.
2.
1.
2.
1.
2.
Faucet will go through the normal start up process.
Make sure there are no objects or people within 3 feet
of the faucet during the start up process.
Faucet will go through the normal start up process.
Make sure there are no objects or people within 3 feet
of the faucet during the start up process.
Plug the data cable into Control Box.
Connect the power cable to Control Box.
Plug data cable into Control Box first.
Connect the power cable to Control Box.
Plug data cable into Control Box first.
Connect the power cable to Control Box.
Troubleshooting / Resolución de Problemas / Résolution de problèmes
Symptom
Probable Cause(s)
Recommended Action(s)
Water does not flow and Blue LED on the
front of the spout does blink.
1. Water supplies are not turned ON.
Low flow in HOT/COLD/BOTH.
1. HOT/COLD/BOTH water supplies are not turned ON.
Turn ON the water supplies (Step 16).
OR
2. Pinched or kinked hoses.
Make sure all hoses are not pinched or kinked.
Only HOT or COLD flow.
3. Clogged filters.
Clean both filters (See pages 16-17).
Sensors not functioning.
1. Protective labels were left on the sensors during faucet
startup process.
Remove the labels from the sensors and repeat faucet startup process.*
2. Sensors are deactivated.
Reactivate sensors (page 15).
OR
Sensor range too short.
Symptom
Turn ON the water supplies (Step 16).
Probable Cause(s)
Recommended Action(s)
Water does not flow and Blue LED on the
front of the spout does blink.
1. Water supplies are not turned ON.
Low flow in HOT/COLD/BOTH.
1. HOT/COLD/BOTH water supplies are not turned ON.
Turn ON the water supplies (Step 16).
OR
2. Pinched or kinked hoses.
Make sure all hoses are not pinched or kinked.
Only HOT or COLD flow.
3. Clogged filters.
Clean both filters (See pages 16-17).
Sensors not functioning.
1. Protective labels were left on the sensors during faucet
startup process.
Remove the labels from the sensors and repeat faucet startup process.*
2. Sensors are deactivated.
Reactivate sensors (page 15).
OR
Sensor range too short.
Symptom
Turn ON the water supplies (Step 16).
Probable Cause(s)
Recommended Action(s)
Water does not flow and Blue LED on the
front of the spout does blink.
1. Water supplies are not turned ON.
Turn ON the water supplies (Step 16).
Low flow in HOT/COLD/BOTH.
1. HOT/COLD/BOTH water supplies are not turned ON.
Turn ON the water supplies (Step 16).
OR
2. Pinched or kinked hoses.
Make sure all hoses are not pinched or kinked.
Only HOT or COLD flow.
3. Clogged filters.
Clean both filters (See pages 16-17).
Sensors not functioning.
1. Protective labels were left on the sensors during faucet
startup process.
Remove the labels from the sensors and repeat faucet startup process.*
2. Sensors are deactivated.
Reactivate sensors (page 15).
OR
Sensor range too short.