Washlight HP squarcle

Washlight HP squarcle
Washlight HP squarcle
Operating Instructions
As of 09/03
DMX Software version HP16T V3.2 and above
amptown lichttechnik gmbh
wandsbeker straße 26
d-22179 hamburg, germany
fon +49 (0) 40 - 64 60 04 - 42
fax +49 (0) 40 - 64 60 04 - 47
technik@amptown-lichttechnik.de
www.amptown-lichttechnik.de
Washlight HP squarcle
with:
w daylight lamp 575 W
w 16-bit servo card
w dipless colour mixing
w dipless daylight to tungsten conversion (CTO)
w dipless focus (7°- 28°)
w barn door effect
Washlight HP squarcle
As of 09/03
1 General Information
1.1
1.2
1.3
1.4
1.5
1
Product Description .................................................................................1
Safety Instructions ..................................................................................1
Technical Data ........................................................................................3
DMX Channel Settings (Software HP16T) ......................................................4
DIP Switch Settings DMX Card....................................................................7
2 Preparing to Operate the Washlight
8
2.1 Power supply ..........................................................................................8
2.2 Lamp (Bulb) ...........................................................................................8
2.3 DMX ......................................................................................................8
3 Functions
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
Dimmer................................................................................................ 10
Shutter ................................................................................................ 10
Pan / Tilt ............................................................................................. 10
Colour Mixing ....................................................................................... 10
Daylight to Tungsten Conversion (CTO)...................................................... 11
Focus .................................................................................................. 11
Auxiliary Channel .................................................................................. 11
Power Down ......................................................................................... 12
Barn Door Effect.................................................................................... 13
Test Mode ............................................................................................ 14
4 Appendix
4.1
4.2
4.3
4.4
4.5
4.6
10
15
Dimensioned Drawings (in mm) ............................................................... 15
Block Diagram....................................................................................... 17
LED Functions ....................................................................................... 18
Stepper Card (X-Lite 10) ......................................................................... 19
Declaration of Conformity ....................................................................... 20
OSRAM HMP - Warnings and Instructions for Use ........................................ 21
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
Washlight HP squarcle
As of 09/03
1 General Information
1.1 Product Description
The Washlight HP is a moving head, Fresnel- or PC-lens spotlight with variable colour
mixing based on the colours yellow, magenta, and cyan. In addition there is a dipless
conversion from daylight to tungsten. As its light source, a highly effective daylight
lamp - surrounded by an elliptical cold-beam dicro-glass reflector - has been employed.
The lamp can be switched on/off via DMX with the possibility of hot restrike. A built-in
mecanical dimmer allows for dipless fades and shutter functions. In the boost mode the
lamp works with 700W. Various beam angles are made possible by a movement of the
front lens. The barn door effect enables variable shaping of the cone of light. In order to
meet the demands of very dynamic movements, the Washlight HP employs extremely
robust and powerful servo motors.
The head of the Washlight HP with daylight lamp is convection-cooled with a special
cooling system - there is only one small ventilator in the base.
The Washlight is controlled internally by a 32-bit high-performance controller as well as a
16-bit DSP (digital signal processor), among others.
All functions can be remote-controlled with the DMX 512/1990 serial interface. For safety
reasons, this interface is galvanically separated from the entire electronics.
Service and maintenance are greatly facilitated due to easy lamp replacement and plug-in
electronic units.
The housing has a black, extremely resistant, powder-coated finished.
1.2 Safety Instructions
The following safety instructions and technical data are necessary for trouble-free
functioning of the unit as well as for the prevention of injury / damage to people /
objects. For this reason, all safety and technical requirements must be followed
without exception. Failure to do so exempts Amptown Lichttechnik GmbH from any
and all liability for both the unit's guarantee / warranty and any resulting injuries
and / or damages.
These instructions should be seen as an integral part of the Washlight HP, and
should be kept with it at all times:
Before opening the unit, it must be removed entirely from the power supply (pull out
the plug)!
Protective Class I: Only insert unit's plug into socket with protective plug
reception with nonfused earth conductor!
The mains cross-sections must be capable of handling
the required power input!
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
1
Washlight HP squarcle
As of 09/03
Allow the bulb to cool before replacing it!
Follow installation instructions provided by the bulb's manufacturer!
Protective type IP 20 (NOT rain-, drip-, or splash-proof)! For outdoor use, a suitable
dome is available.
Keep away from all flammable materials (see diagrams below for distances to be
maintained)!
0,5 m
1,0 m
Unit's ventilation slits should never be covered or blocked, and must be cleaned when
dirt / dust builds up!
Never insert any bodily parts or other objects through the housing openings into the
unit!
In case of malfunction, the unit must be removed immediately and entirely from the
power supply, and may not be operated again until personnel described below has
undertaken repairs!
The unit may be operated from any position.
It is of utmost importance that there be enough room for the lamp yoke's and head's
pan and tilt movements!
Required free space incl. unit: 500x500x750 mm (Width x Depth x Height, standing
on ground)
The unit may not be operated within reach of people and / or any accidental contact
with the unit must be prevented via appropriate warning signs or barriers!
When operating the unit from a hanging position, the unit must be secured via the
mounting brackets designed for this purpose. To do so, two points with a loadcarrying capacity of 250 Newtons each are necessary.
Repair service and maintenance on and within the unit are to be carried out by
qualified personnel only! These qualified personnel must either have well-founded
technical knowledge or have received instructions from the manufacturer.
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
2
Washlight HP squarcle
As of 09/03
1.3 Technical Data
Power supply:
180 - 255 V / 50 - 60 Hz
Power consumption:
900 VA max.
Mains Connection:
1 Meter H07RN-F 3G1,5² with plug
Signal (galvanically separated):
- Input (Rin = 800 Ohm):
- Output (activ, 60mA):
DMX 512/1990 - 16 channels
XLR 5-pol, male
XLR 5-pol, female
Input and Output must not be exchanged in function!
DMX pin configuration:
pin 1 = GND (shield)
pin 2 = data pin 3 = data +
Movement:
pan = 340°
tilt = 270°
Dipless colour mixing:
cyan, magenta, yellow (CMY)
Dipless conversion:
6000K ... approx. 3400K
Variable focus/beam angle:
approx. 7° - 28° (with Fresnel lens)
Build-in mechanical dimmer:
0 - 100%
Max. ambient temperature:
ta = 40°C
Max. housing temperature:
tmax = 90°C (at head´s end)
Weight:
25 kg
Lamp:
OSRAM HMP 575 SE
Lamp power:
400W (power down)
575W (normal operation)
700W (boost)
Design and technical detail subject to change.
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
3
Washlight HP squarcle
As of 09/03
1.4 DMX Channel Settings (Software HP16T)
Channel 1 = dimmer, dipless fades
Decimal
0
255
Percentage
0%
100%
HEXHEX-Code
00 H
FF H
Function
brightness 0%
brightness 100%
Channel 2 = shutter
Decimal
0
15
25
35
45
55
65
Percentage
0%
6%
10%
14%
18%
22%
26%
HEXHEX-Code
00 H
0F H
19 H
23 H
2D H
37 H
41 H
75
30%
4B h
85
95
105
115
125
135
145
155
165
175
185
195
205
215
225
235
255
33%
37%
41%
45%
49%
53%
57%
61%
65%
69%
73%
76%
80%
84%
88%
92%
100%
55 H
5F H
69 H
73 H
7D H
87 H
91 H
9B H
A5 H
AF H
B9 H
C3 H
CD H
D7 H
E1 H
EB H
FF H
Function
shutter closed
strobe 1 - slow
strobe 2
strobe 3
strobe 4
strobe 5 - fast
random strobe 1
construction)
random strobe 2
construction)
strobe, soft - soft
strobe, soft
strobe, soft
strobe, soft
strobe, soft
strobe, soft
strobe, soft
strobe, soft - fast
strobe, hard - slow
strobe, hard
strobe, hard
strobe, hard
strobe, hard
strobe, hard
strobe, hard
strobe, hard - fast
shutter open
(under
(under
Channel 3 = Movement, horizontal, pan - coarse
Decimal
0
127
255
Percentage
0%
50%
100%
HEXHEX-Code
00 H
7F H
FF H
Function
horizontal -170°
horizontal 0° (mid-position)
horizontal +170°
Channel 4 = Movement, horizontal, pan - fine
Decimal
0
127
255
Percentage
0%
50%
100%
HEXHEX-Code
00 H
7F H
FF H
Function
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
4
Washlight HP squarcle
As of 09/03
Channel 5 = Movement, vertical, tilt - coarse
Decimal
0
127
255
Percentage
0%
50%
100%
HEXHEX-Code
00 H
7F H
FF H
Function
vertical -135°
vertical 0° (mid-position)
vertical +135°
Channel 6 = Movement, vertical, tilt - fine
Decimal
0
127
255
Percentage
0%
50%
100%
HEXHEX-Code
00 H
7F H
FF H
Function
Channel 7 = Yellow, dipless
Decimal
0
220
Percentage
0%
86%
HEXHEX-Code
00 H
DC H
Function
no yellow (clear)
full yellow
Channel 8 = Magenta, dipless
Decimal
0
220
Percentage
0%
86%
HEXHEX-Code
00 H
DC H
no magenta (clear)
full magenta
Function
HEXHEX-Code
00 H
DC H
no cyan (clear)
full cyan
Channel 9 = Cyan, dipless
Decimal
0
220
Percentage
0%
86%
Function
Channel 10 = colour conversion (CTO), dipless
Decimal
0
220
Percentage
0%
86%
HEXHEX-Code
00 H
DC H
Function
daylight 6000 Kelvin
tungsten approx. 3400 Kelvin
HEXHEX-Code
00 H
DC H
flood - beam angle 28°
spot – beam angle 7°
Channel 11 = focus, dipless
Decimal
0
220
Percentage
0%
86%
Function
Channel 12 = Auxiliary Channel (normal:DIP8 OFF): Reset servo & stepper
Decimal
from 0
to
31
from 32
to 201
202
203
204
from 205
to 255
Percentage
Percentage
0%
12%
13%
79%
...
...
...
80 %
100%
HEXHEX-Code
00 H
1F H
20 H
C9 H
CA h
CB H
CC H
CD H
FF H
Function
normal operation
normal operation
lamp off
lamp off
RESET - servo
RESET - stepper + servo
RESET - stepper
boost, 700W
boost, 700W
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
5
Washlight HP squarcle
As of 09/03
Channel 12 = Auxiliary Channel (Extra: DIP8 ON): Reset servo & stepper
Decimal
from 0
to
50
from 51
to 100
from 101
to 150
from 151
to 201
202
203
204
from 205
to 239
from 240
to 255
Percentage
0%
19,6%
20%
39,2%
39,6%
58,8%
59,2%
78,8%
79,2%
79,6%
80,0%
80,4%
93,7%
94,1%
100%
HEXHEX-Code
00 H
32 H
33 H
64 H
65 H
96 H
97 H
C9 H
CA H
CB H
CC H
CD H
EF H
F0 H
FF H
Function
no change
no change
lamp on, 575W
lamp on, 575W
lamp off
lamp off
no change
no change
RESET - Servo
RESET – Servo + Stepper
RESET - Stepper
no change
no change
Boost, 700W
Boost, 700W
Channel 13 = Barn Door Rotation
Decimal
0
255
Percentage
0%
100%
HEXHEX-Code
00 H
FF H
Function
st
1 Stop
nd
2 Stop
Channel 14 = Barn Door 1/2
Decimal
0
255
Percentage
0%
100%
HEXHEX-Code
00 H
FF H
doors open
doors closed
Function
HEXHEX-Code
00 H
FF H
door open
door closed
HEXHEX-Code
00 H
FF H
door open
door closed
Channel 15 = Barn Door 3
Decimal
0
255
Percentage
0%
100%
Function
Channel 16 = Barn Door 4
Decimal
0
255
Percentage
0%
100%
Function
Note:
yellow
+ magenta
magenta + cyan
cyan
+ yellow
= red
= blue
= green
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
6
Washlight HP squarcle
As of 09/03
1.5 DIP Switch Settings DMX Card
Software version DMX-2: WL-HP16T V 3.2 and above
Switch (S2) in front on the DMX card:
DIP
Function
1
2
failure input
3
DMX start address
4
no DMX signal
on
off
active
blocks of 16 channels
maintain current settings
passive
1 ... 512 (individual)
basic position (default)
Switch (S1) in back on the DMX card (the card must be pulled out):
DIP
Function
on
5
DMX channel 12 (aux.)
passive
6
Lamp after DMX failure
off
7
Boost function
off (for HMI 575)
8
Auxiliary channel type
Mode 2 (extra)
Jumper in back on the DMX card (the card must be pulled out):
DIP
Function
in
7
Barn Door channels (13..16)
on (16 channels)
6
5
4
off
active
on
on
Mode 1 (normal)
open
off (12 channels)
boldface: adjustment on delivery
S1
S2
1 2 3 4
DIP 8
DIP 7
DIP 6
DIP 5
J4
J5
J6
J7
DMX-2
HP16T V3.2
DIP 1
DIP 2
DIP 3
DIP 4
DMX-2 Typ:
HP 16
1
2
3
4
Lichttechnik
AMPTOWN
MC 68332
DMX-2
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
7
Washlight HP squarcle
As of 09/03
2 Preparing to Operate the Washlight
2.1 Power supply
The Washlight comes with a standard 1-metre power supply cable and shrouded contact
plug. The power supply cable must be plugged into a socket with protective plug
reception and nonfused earth conductor. The socket's fuse should be not less than 6
amps and not greater than 16 amps.
2.2 Lamp (Bulb)
There is currently only one bulb available:
OSRAM HMP 575 SE
The manufacturer specifies the lamp has a 1000h average operational lifetime.
Please follow bulb manufacturer's instructions!
2.3 DMX
DMX connection is done via a regular 5-pin XLR connector (e.g., Switchcraft, Neutrik).
Input (DMX in):
Output (DMX out):
male
female
Pin:
1 = Ground (GND)
2 = Data 3 = Data +
The DMX LED will light up green when the DMX data are valid; if not, it will be yellow. If
there is no DMX signal, the unit's performance is adjusted on the DMX card with DIP
switch 4: either maintain current settings or go to basic position (default).
If an invalid DMX address is entered, the DMX LED will blink green/yellow and the moving
light will return to its basic position (default). For the addresses 800 and upward, a test
mode is implemented; with this mode, it is possible to check the unit's individual
functions - including without DMX.
For operational safety and conformity to European CE regulations, only shielded DMX
cable may be used. The shield must be on Pin 1 (ground).
For safety reasons, the DMX inputs and outputs are galvanically separated from the entire
electronics.
In order to increase operational reliability, each output is "active"; i.e., the DMX signal
is boosted by each unit. This means that any number of ControLite moving lights can be
connected to one DMX line. A terminating resistance is not necessary.
If a unit is not connected to the power supply, the DMX signal is automatically looped
through.
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
8
Washlight HP squarcle
As of 09/03
If the DMX signal has to be manually split, a maximum of two Washlights can be directly
connected to one output. Should you need to run more than two units parallelly, an
active splitbox is required.
The DMX input within the unit has an impedance of 800 Ohm.
L
prohibited
DMX in- and outputs must not
be mixed-up.
The Washlight controls require 16 DMX channels per unit.
Please refer to section 1.4 DMX for channel distribution and their corresponding
functions.
The start address for the first channel of the unit must be defined using the three-digit
code switch located on the yoke.
J
TIP
Setting a new start address may cause the yoke to
change position and wiggle around.
To avoid movement while setting a new start address,
press the "RESET" button at the same time.
The Washlight does not have to be connected to the power supply in order to enter the
unit's start address!
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
9
Washlight HP squarcle
As of 09/03
3 Functions
3.1 Dimmer
The mecanical dimmer is built into the Washlight. You may control this function via the
DMX 512 interface on Channel 1 from 0 = "off" to 255 = "on".
3.2 Shutter
The shutter function is based on the mechanical dimmer, but uses its own DMX channel.
Use Channel 2 to cause “shutter closed“ at 0 to “shutter open“ at 255.
3.3 Pan / Tilt
The unit's servo card controls movement of both axes (head and yoke). For both axes,
there is a corresponding channel for coarse and fine adjustment.
Channel 3 = yoke / pan
Channel 4 = yoke / pan
coarse (DMX 0 - 255)
fine (DMX 0 - 255)
Channel 5 = head / tilt
Channel 6 = head / tilt
coarse (DMX 0 - 255)
fine (DMX 0 - 255)
As soon as the light is connected to the power supply, the servo card executes a set-up
movement (servo reset) on its own. During this procedure, all positions are carried out at
slow speed. Also, the servo LED blinks during this time.
The card is equipped with overload protection for the gears. If one of these precautionary
measures registers a malfunction, the red servo LED will come on immediately and the
motors will disengage. If you are unable to solve the problem by pushing "RESET" or by
briefly disconnecting from the power supply, there is a malfunction.
3.4 Colour Mixing
For infinitely variable colour mixing, there are three basic colours (yellow, magenta, and
cyan) available. Their channel distribution via the DMX interface is as follows:
Channel 7 = yellow
Channel 8 = magenta
Channel 9 = cyan
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
10
Washlight HP squarcle
As of 09/03
The following control info applies to all three colours:
DMX 0
DMX 220
/ 0%
/ 86%
/00H = none of the corresponding colour
/DCH = satured (full) colour
DMX values higher than the above-mentioned maximum setting (220 / 86% / DCH)
correspond to the saturated colour as well.
J
TIP
yellow
+ magenta
magenta + cyan
cyan
+ yellow
= red
= blue
= green
For best colour mixing results, use only two colours at
the same time. Using all three colours at once will not
result in good colour mixing, but does create a fade-out
effect.
For a black-out effect, set all colours on full intensity.
Theremaining light will be less than 5%. Fading out the
dimmer at the same time creates a nice black out.
3.5 Daylight to Tungsten Conversion (CTO)
There is a separate effect wheel for conversion from daylight (6000K) to tungsten
(approx. 3400K), which allows for dipless conversion via DMX Channel 10.
DMX 0
DMX 220
/ 0%
/ 86%
/00H = daylight (6000K)
/DCH = tungsten (3400K)
Also, the Washlight comes with an optimal wheel with four fixed colours instead of the
CTO wheel.
3.6 Focus
The focus allows you to diplessly change the beam angle from 7° to 28°. Control of this
function is via DMX Channel 11. Resolution is 8-bit. It takes approx. 2 seconds for the
entire procedure (7° --> 28°).
3.7 Auxiliary Channel
The DMX Channel 12 controls three aux functions :
lamp on/off, lamp boost and reset.
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
11
Washlight HP squarcle
As of 09/03
Normal Mode: (DIP8 off)
Values 0 to 31 run the lamp at the standard setting (575W). Values 32 to 202 switch the
lamp off (the lamp LED indicates “red“). Remember: Only switch off the lamp for longer
periods of time, as any restart of the lamp reduces its lifetime by hours.
Three different resets are controlled by the aux channel:
With DMX setting 202, only a servo reset is carried out.
With DMX setting 203, both a servo and a stepper reset are carried out.
With DMX setting 204, only a stepper reset is carried out.
Values 204 to 255 run the lamp at the 700W boost setting; the lamp LED indicates
“yellow“. Keep in mind that using the boost setting not only increases the brightness but
also reduces the average lifetime by about 50%.
In order to mountain connect data on the bulb’s while in boost mode, the built-in
counter correspondingly runs at twice its normal speed when using 700W.
Extra Mode: (DIP8 on)
Values 0 to 50 cause no changes. Values 51 to 100 run the lamp at the standard setting
(575W); the lamp LED indicates “green”. Values 101 to 150 switch the lamp off; the lamp
LED indicates “red“. Remember: Only switch off the lamp for longer periods of time, as
any restart of the lamp reduces its lifetime by hours. Values 151 to 201 cause no
changes.
Three different resets are controlled by the aux channel:
With DMX setting 202, only a servo reset is carried out.
With DMX setting 203, both a servo and a stepper reset are carried out.
With DMX setting 204, only a stepper reset is carried out.
Values 205 to 239 cause no changes. Values 240 to 255 run the lamp at the 700W boost
setting; the lamp LED indicates “yellow“. Keep in mind that using the boost setting not
only increases the brightness but also reduces the average lifetime by about 50%.
In order to mountain connect data on the bulb’s while in boost mode, the built-in
counter correspondingly runs at twice its normal speed when using 700W.
Note: The 700W boost mode is not made for continuos operation.
3.8 Power Down
In order to avoid overheating of the washlight HP when the dimmer is closed (values 0
to 4), the bulb switches into power-down mode after about 30 seconds. You will also find
the stepper LED indicating „yellow“, then. The stepper LED indicates “yellow”. Due to the
fact that the bulb runs on 400W in power down, the approximate lifetime of the lamp
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
12
Washlight HP squarcle
As of 09/03
will be reduced as much as if running in boost mode (700W). Therefore the built-in
counter will run at twice its normal speed as it does in boost mode, to maintain connect
data on the bulb’s lifetime.
3.9 Barn Door Effect
The barn door effect allows the lighting designer to shape the spot's beam. To do so,
there are 4 doors available: DMX Channel 14 controls doors (1 / 2), Channel 15 door 3
and Channel 16 door 4. The doors can be brought into the desired position via DMX
Channel 13 (door rotation).
Once the doors are activated, the washlight revents from boost mode to standard
mode.
Please keep in mind that the motors are meant to position the doors, but are NOT
made for a constant movement effect!
L
prohibited
Never pull out electrical plugs
while the Washlight is in
operation. Damage to the
electronics could result.
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
13
Washlight HP squarcle
As of 09/03
3.10 Test Mode
A test mode has been implemented in the DMX software, version HP16T V3.0 and above;
this mode allows you to check the Washlight functions directly (including without DMX).
Select the test mode via the BCD code switch (which is normally responsible for selecting
the DMX start address).
The individual test functions:
BCD Switch
DMX Channel Function
800
...
Lamp on only
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Dimmer 100%, pan & tilt 50%
Shutter - Strobe 5, pan & tilt 50%
Dimmer 0%, Pan coarse 100%, tilt 0%
Dimmer 0%, Pan coarse + fine 100%, Tilt 0%
Dimmer 0%, Pan 0%, Tilt coarse 100%
Dimmer 0%, Pan 0%, Tilt coarse + fine 100%
Dimmer 100%, pan & tilt 50%, yellow 100%
Dimmer 100%, pan & tilt 50%, magenta 100%
Dimmer 100%, pan & tilt 50%, cyan 100%
Dimmer 100%, pan & tilt 50%, CTO 100%
Dimmer 100%, pan & tilt 50%, focus 100%
Dimmer 100%, pan & tilt 50%, boost - 700W
Dimmer 100%, pan & tilt 50%, door rotation 100%
Dimmer 100%, pan & tilt 50%, doors 1/2 100%
Dimmer 100%, pan & tilt 50%, door 3 100%
Dimmer 100%, pan & tilt 50%, door 4 100%
900
...
Lamp off only
000
496 to 799
817 to 899
901 to 999
/
/
/
/
default settings, DMX LED blinks yellow/green
default settings, DMX LED blinks yellow/green
default settings, DMX LED blinks yellow/green
default settings, DMX LED blinks yellow/green
The lamp can be switched on and off with the codes 800 and 900.
Codes 801 to 816 correspond to DMX channels 1 to 16, the lamp setting does not
change.
With all other invalid DMX start addresses, the Washlight will go to its default position:
head horizontal, yoke 50%, focus forward, door rotation 100%, the rest 0%.
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
14
Washlight HP squarcle
As of 09/03
4 Appendix
4.1 Dimensioned Drawings (in mm)
Side View
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
15
Washlight HP squarcle
As of 09/03
Front View
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
16
Washlight HP squarcle
As of 09/03
M
4
9
M
CTO
16.07.02
Blatt 1 / 1
hp_tvt_e.vsd
G.Gandolfo
M
7
Lichttechnik
M
M
2
7
5
focus
M
7
3
cyan
M
7
2
magenta
BASIS
PCB
Amptown
4
6
6
barn door rotation
4
STEPPER Card
X-Lite 10
9
Reset
DMX
Servo
Stepper
Lamp
7
barn doors 1+2
M
M
4
4
8
barn door 3
Block diagram
M
4
10
DMX-2
Card
M
X-axis
barn door 4
512
ControLite Washlight - HP TV /T
incremental encoder
M
2
Y-axis
4
2
8
4
DuoSERVO
Card
20
4
4.2 Block Diagram
M
7
1
yellow
dimmer
lamp
socket
fan
bulb
HMP 575 SE
2
2
ignitor
on/off
electronic
ballast
2
boost
2
WLHPVG
PCB
filter
2
power supply
6
2
2
7
2
counter
safety lamp off
3
mains
DMX - OUT
yoke
DMX - IN
3
3
fuse
3
mains
base
head
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
17
5 1 2
stepper O.K.
575W lamp on
Servo
Stepper
Lamp
Reset switch
DMX O.K.
servo O.K.
DMX
green
LED:
700W lamp boost
400W power down/stepper reference
---
no DMX
yellow
Functions of the LEDs on the BASIS PCB:
Lichttechnik
Amptown
lamp off
stepper failure
servo failure
---
red
LED - functions
ledhptve.vsd
G.Gandolfo
05.05.03
sheet 1 /1
ControLite Washlight - HP TV
---
---
servo reference
DMX address not O.K.
flash
Washlight HP squarcle
As of 09/03
4.3 LED Functions
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
_________________________________________________________________________
18
Washlight HP squarcle
As of 09/03
not used (on)
not used (on)
RS-485 data
not used (on)
/T
HX .x
1
not used (on)
1
yellow
2
1
magenta
3
1
cyan
4
x_hpt_e.vsd
G. Gandolfo
dimmer
1
X-Lite 10
LED:
ControLite Washlight HP ../T
stepper motors:
05.05.03
Blatt 1 /1
4.4 Stepper Card (X-Lite 10)
Amptown
CTO
5
Stepper Card (X-Lite 10)
1
focus
6
LED:
1
barn door rotation
7
not used (off)
Lichttechnik
1
watchdog
1
+5V
+ 24 V
barn doors 1/2
8
1
barn door 3
9
1
Jumper:
barn door 4
J1
J2
J3
J4
10
1
1
Supply connection:
Stepper connection:
Pin
Colour
Signal
Pin
Colour
Signal
1
yellow
RS 485 + data
1
black
stepper winding 1
2
green
RS 485 - data
2
brown
stepper winding 1
3...5
n.c.
3
red
stepper winding 2
6
orange
signal stepper
4
orange
stepper winding 2
7
brown
GND
5
yellow
GND
8
violet
+ 5V
6
green
+ 5V - Vcc
9,10
black
GND - motor
7
blue
output: zero signal
11,12
red
+ 24V - motor
Jumper:
LED:
No.
Function
Function
Description
1
auto correction off
RS 485 data
flashes receiving new data
2
res.
3
res.
watchdog
flashes with software failure or after reset
4
res.
+5V
always on
+ 24 V
always on
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
19
Washlight HP squarcle
As of 09/03
4.5 Declaration of Conformity
Manufacturer:
Amptown Lichttechnik GmbH
Wandsbeker Str. 26
D-22179 Hamburg
Germany
Product Name:
ControLite
Type of Product:
Washlight HX (Halogen) and Washlight HP (High Power)
We declare that the products listed above meet the
electromagnetic compatibility requirements of the European
Commission Directive and comply with the requirements of the
Directive by meeting the following standards:
Safety:
EN 60598-1
EN 60598-2-17
VGB 70
EMC:
EN 55103-1
EN 55103-2
EN 50081-1
EN 50082-1
Hamburg, July 10th 1997
_____________________
Dipl.-Ing. Michael Knappe
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
20
Washlight HP squarcle
As of 09/03
4.6 OSRAM HMP - Warnings and Instructions for Use
_________________________________________________________________________
 amptown lichttechnik GmbH + d-22179 hamburg + wandsbeker str. 26 + fon +49 / (0)40 / 64 60 04-42 + fax ...-47
21
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising