Bold Line 2012 - Warner Instruments

Bold Line 2012 - Warner Instruments
Integrated Components
for Live-Cell Imaging
microscope incubators,
gas controllers, and
thermal plates
Gas Controllers CO2 - O2
Warner Instruments is pleased to present the complete line of gas
controllers from Okolab. This family of controllers includes the basic
manual mixers, featuring floating ball flow meters to mix the gas streams
and the DGT Line offers digital control of CO2 or O2 and floating ball
meters to set the airflow rate. The Bold Line controllers offer full digital
control over the gas mixtures, are fully intergraded with the Bold Line
temperature controllers, and can be operated via touch screen interface,
OKO-Control 2.0 software, or Nis Elements software.
Bold Line CO2/O2 Multi-User
DGT Line Digital CO2/O2 Manual Air
Bold Line Digital CO2
Touch Controller
2
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.comm
Manual Mixers
Two Gas Mixer (2GF-MIXER)
•
•
•
•
Set point resolution 1%
Works with any microscope incubator
CO2 concentrations in the 0-15% range
Reusable PTFE membrane filter (0.2 mm pores)
Description
The 2GF MIXER is a two-gas mixer used to generate CO2-Air mixtures with an
adjustable CO2 concentration in the range of 0-15%. The mixer can be used
as a stand-alone device or in combination with any microscope incubator. Air
and CO2 flows are regulated using dual floating ball flow meters that operate
in the range of 0.2 -1.7 Nl/min and 0.013 - 0.13 Nl/min, respectively.
Manual Mixers Manual CO2/O2 Manual Air
Three Gas Mixer / (3GF Mixer-Hypoxia)
Manual CO 2 - Manual N 2 - Manual Air
•
•
•
•
CO2 range 0 - 15%
O2 range 2 - 20%
Set point resolution 1%
PTFE membrane filter (0.2 mm pores)
Description
The 3GF Mixer-Hypoxia is a 3-gas mixer (Carbon Dioxide, Nitrogen, Air) that
employing floating ball flow meters.
Manual Mixers 3GF-Mixer
Three Gas Mixer / (3GF Mixer-Hyperoxia)
Manual CO 2 - Manual N 2 - Manual Air
•
•
•
•
CO2 range 0 - 15%
O2 range 40 - 85%
Set point resolution 1%
PTFE membrane filter (0.2 mm pores)
Order #
Model
Product
Manual Mixers
64-1996
2GF-Mixer
2 Gas mixer, Air and CO2 0-15%
64-1997
3GF-Mixer-Hypoxia
3 Gas mixer, Air Nitrogen and CO2,
O2-2-20%
64-1998
3GF-Mixer-Hyperoxia
3 Gas mixer, Air Nitrogen and CO2,
O2-40-85%
Description
The 3GF Mixer-Hyperoxia is a 3 gas mixer (Carbon Dioxide, Nitrogen, Air)
which employs floating ball flow meters. Gas connectors and valves are
cleaned for use with oxygen.
3
Accessories
64-1999
OKO-AP
Air pump max pressure 300 mbar
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Digital Gas / Manual Air Mixers
DGT Gas Controllers / (CO2 DGT-BX)
Digital CO2 / Manual Air
•
•
•
•
•
•
•
•
•
•
•
•
Adds CO2 to Air or N2
CO2 Range 0-20%
Accuracy ± 5% of CO2 concentration
Repeatability better than 0.1%
Floating ball air flow meter 0-1 Nl/min
Total flow rate (at 5% CO2) 0.5 Nl/min
Outlet pressure: Ambient
CO2 consumption (at 5% and air flow rate 0.5
Nl/min): 0.027 Nl/min
CO2 sensor Non Dispersive infrared (NDIR) dual
wave length detector
Software control with OKO Control 2012 or NISElements
Filtering device PTFE membrane with 0.2 µm pores
Can work in series with O2 DGT BX HYPOXIA
DGT CO2 DGT-BX
Description
An infrared sensor continuously measures CO2 levels in the mixed gas stream
and a PID closed loop controller provides feedback to a fine valve regulating
CO2 flow. Air flow is manually regulated with a floating ball flow meter.
A serial RS-232 interface and OKO-Control 2.0 Software allow the user to
control the unit using a personal computer and to acquire concentration data
stored in computer memory.
The CO2 controller is supplied with the following: gas filter, pressure gauge
for CO2 with regulator, two white rigid tubes: 6mm O.D. 3m length one blue
rigid tube: 6mm O.D. 2 m length
Optional Air Pump is a good choice for labs lacking a source of clean air.
DGT CO2 DGT-BX rear panel
Order #
Model
Product
DGT Mixers
64-1991
DGT-CO2BX-PLUS
Digital CO2 / manual Air CO2 0-20%
Accessories
64-1999
OKO-AP
Air pump max pressure 300 mbar
Optional Air Pump
4
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Digital Gas / Manual Air Mixers
DGT Gas Controllers / (O2 DGT-BX Hypoxia)
Digital O2 / Manual Air
•
•
•
•
•
•
•
•
•
•
•
•
Adds N2 to Air
O2 Range 1-19%
Accuracy: ± 0.1% at 5% O2
Repeatability: Better than 0.05% of [O2]
Floating ball air flow meter 0-0.4 Nl/min
Total flow rate (at 5% O2) 0.5 Nl/min
Outlet pressure: Ambient
N2 consumption (at 5% O2) 0.5 Nl/min
O2 sensor Zirconium oxide with 10-year life
Software control with OKO Control or NIS-Elements
Filtering device PTFE membrane with 0.2 µm pores
Works in series with CO2 DGT BX
DGT O2 DGT-BX Hypoxia
Description
Technology
The O2 DGT-BX HYPOXIA controls O2 concentration by mixing Air with
Nitrogen. Air flow is set to 0.1 liter per minute by means of a floating ball
flowmeter. When combined with the Digital CO2 Controller, control over 3
gas Mixtures (Nitrogen-Carbon Dioxide-Oxygen) is achieved.
The long life zirconium oxide sensor lasts up to 10-years if continuously used
and considerably longer if used intermittently.
Data Storage
The serial RS-232 interface and Oko-control software allow the user to
control the unit and to acquire and store data on a PC compatible computer.
DGT O2 DGT-BX Hypoxia rear panel
Accessories
The O2 controller is supplied with the following: Gas filter, pressure gauge
for N2 with regulator, two white rigid tubes: 6mm O.D. 3m length
Order #
Model
Product
DGT Mixers
64-1992
DGT-CO2BX-ES
Digital CO2 w/ external sensor
64-1993
DGT-O2BX-PLUS
Digital O2 / manual Air O2 - 3-19%
Accessories
64-1999
OKO-AP
Air pump max pressure 300 mbar
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
5
Bold Line CO2 Controller
Description
The Bold Line CO2 controller mixes Air or N2 with CO2, and controls the
concentration with digital accuracy. Operation is via an easy to use touch
screen interface, OKO-Touch. An optional Smart Box data logger and web
server allows operation via any web-enabled device. The system may also
be operated via a PC using OKO-Control 2.0 software or Nis Elements
software.
Sensor calibration is made using an external meter or calibration gas.
The controller can be attached to O2 Unit-BL [1-20] to control both CO2 and
O2 within the range 0-10% and 0-18%, respectively.
Technical Specifications
Operating mode
Concentration range
Accuracy
Set Point Resolution
Repeatability
Total flow rate
Outlet pressure
CO2 consumption (at 5%)
CO2 sensor
Filtering device
Adds CO2 to Air or N2
0-18%
± 5% of CO2 concentration, i.e. ± 0.25% at 5%
CO2
0.1%
Better than 0.1%
0.4 Nl/min - constant
Ambient
0.02 Nl/min
10 year-life Non Dispersive infrared (NDIR)
dual wave length detector
PTFE membrane with 0.2 µm pores
Optional Bold Line Air Pump
Order #
Model
Product
Bold Line Controllers
64-2000
CO2 Unit-BL
CO2/ Air - CO2 0-18%
64-2007
Oko-Touch
Touch screen display
Accessories
6
64-2008
64-2001
SM-BL
O2 Unit-BL[1-20]
Smart Box, data logger, web server
O2 1 - 20.5%
64-2006
OKO-AP_BL
Bold Line Air Pump max pressure 300
mbar
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Bold Line O2 Controller
Description
The Bold Line O2 unit controls the oxygen concentration over the range of 120% by mixing Air with Nitrogen. Gas flow rates are digitally controlled. A
long life zirconium oxide sensor precisely measures the O2 concentration
with high precision.
Operation is via an easy to use touch screen interface, OKO-Touch. An
optional Smart Box data logger and web server allows operation via any
web-enabled device. The system may also be operated via a PC using OKOControl 2.0 software or Nis Elements software.
Sensor calibration is made with an external meter or calibration gas.
The controller can be attached to CO2 Unit-BL to control both CO2 and O2.
Technical Specifications
Operating mode
Concentration range
Accuracy
Repeatability
Set Point Resolution
Total flow rate
Outlet pressure
N2 consumption (at 5% of O2)
O2 sensor
Filtering device
Adds N2 to Air
0-20%
± 0.1% @ 5% of O2
0.05% of O2
0.1%
0.4 Nl/min - constant
Ambient
0.03 Nl/min
10 year-life zirconium oxide sensor
PTFE membrane with 0.2 µm pores
Order #
Product
Model
Bold Line Controllers
64-2001
O2 Unit-BL[1-20]
O2 1 - 20.5%
64-2007
Oko-Touch
Touch screen display
Accessories
64-2008
64-2000
SM-BL
CO2 Unit-BL
Smart Box, data logger, web server
CO2 / Air - CO2 (0-18%)
64-2006
OKO-AP_BL
Bold Line Air Pump max pressure 300
mbar
A typical complete system
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
7
Bold Line CO2 - O2 Controllers
Technical Specifications CO2-O2 UNIT-BL [0-10;1-18]
Operating mode
Concentration range
CO2 Accuracy
O2 Accuracy
Set Point Resolution
CO2 Repeatability
O2 Repeatability
Total flow rate
Outlet pressure
CO2 consumption (at 5%)
N2 consumption (at 5% of O2)
CO2 sensor
Description
CO2-O2 UNIT-BL [0-10;1-18] and [0-20;1-95]
The Bold Line combination CO2 - O2 gas controllers are ideal for hypoxia and
hyperoxia experiments. Two versions are available, CO2; 0-10% and O2; 118%, and CO2; 0-20% and O2; 1-95%.
Gas flow rates are digitally controlled. A long life zirconium oxide sensor
precisely measures the O2 concentration, a non dispersive infrared
(NDIR) dual wave length detector sets the CO2 concentration.
Operation is via an easy to use touch screen interface, OKO-Touch. An optional
Smart Box data logger and web server allows operation via any web-enabled
device. The system may also be operated via a PC using OKO-Control 2.0
software or Nis Elements software.
Sensor calibration is made using an external meter or calibration gas.
O2 sensor
Filtering device
Adds CO2 and N2 to Air
CO2 range: 0-10%, O2 range: 1-18%
± 5% of CO2 concentration, i.e. ± 0.25% at
5% CO2
0.1% at 5% O2
0.1%
Better than 0.1%
0.05% of O2
0.4 Nl/min - constant
Ambient
0.02 Nl/min
0.3 Nl/min
10 year-life Non Dispersive infrared (NDIR)
dual wave length detector
10 year-life zirconium oxide sensor
PTFE membrane with 0.2 µm pores
Technical Specifications CO2-O2 UNIT-BL [0-20;1-95]
Operating mode
Concentration range
CO2 Accuracy
O2 Accuracy
Set Point Resolution
Total flow rate
Outlet pressure
CO2 consumption
O2 consumption
N2 consumption
Digital Flow Meters
CO2 sensor
O2 sensor
Filtering device
Order #
Model
Mixes CO2, O2, and N2
CO2 range: 0-20%, O2 range: 1-95%
± 0.3 % at 5% CO2 and 5% O2
± 0.2% at 5% CO2 and 5% CO2
0.1%
0.35 Nl/min - constant
Ambient
(at 5% of CO2): 0.0175 Nl/min
(at 5% of O2): 0.0175 Nl/min
(at 5% of CO2 and at 5% of O2): 0.315 Nl/min
CMOS Sensors
10 year-life Non Dispersive infrared (NDIR)
dual wave length detector
10 year-life zirconium oxide sensor
PTFE membrane with 0.2 µm pores
Product
Bold Line Controllers
64-2002
CO2-O2 Unit-BL[1-10:1-18]
Combined CO2 / O2
64-2003
CO2-O2 Unit-BL[1-20:1-95]
Combined CO2 / O2
64-2007
Oko-Touch
Touch screen display
Accessories
8
64-2008
SM-BL
Smart Box, data logger, web server
64-2006
OKO-AP_BL
Bold Line Air Pump max pressure 300 mbar
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Bold Line Three Gas Mixer Multi-user
Description
CO2-O2 UNIT-BL CP
Designed supply desired Air-CO2 or N2-O2-CO2
mixture at controlled pressure
The CO2 O2 Unit BL CP replaces pre-mixed tanks or compressed gas lines, a
single unit supplies up to 10 microscope incubators.
The device mixes two or three gases, according to the operator's need.
Technical Specifications CO2-O2 UNIT-BL [0-20;1-95]
Output pressure
Pressurized Vessel
Operating mode
Concentration range
CO2 Accuracy
Sensor calibration is made using an external meter or calibration gas.
O2 Accuracy
Set Point Resolution
CO2 repeatability
O2 repeatability
Total flow rate
CO2 consumption
Air consumption
N2 consumption
CO2 sensor
Note: Order Single floating ball flowmeters along with the Multi-user
controller, one for each incubator to be connected.
O2 sensor
Filtering device
A long life zirconium oxide sensor precisely measures the O2 concentration
and a non dispersive infrared (NDIR) dual wave length detector sets the
CO2 concentration. Operation is via an easy to use touch screen interface,
OKO-Touch.
An optional Smart Box data logger and web server allows operation via any
web-enabled device. The system may also be operated via a PC using
OKO-Control 2.0 software or Nis Elements software.
Order #
Model
1-4 atm (absolute pressure)
5 liter
Adds CO2 and Air to N2
CO2 range: 4-8%, O2 range: 3-7%
± 5% of CO2 concentration, i.e. ± 0.25% at 5%
CO2
0.1% at 5% O2
0.1%
better than 0.1%
0.05% of O2
0.5 Nl/min (at 4 ata)
(at 6% of CO2): 0.042 Nl/min
(at 6% of CO2 and 5% O2): 0.167 Nl/min
(at 5% of O2): 0.5 Nl/min
10 year-life Non Dispersive infrared (NDIR)
dual wave length detector
10 year-life zirconium oxide sensor
PTFE membrane with 0.2 µm pores
Product
Bold Line Controllers
64-2004
CO2-O2 Unit-BL CP
Multi-user combined CO2 / O2
64-2007
Oko-Touch
Touch screen display
Accessories
64-2008
SM-BL
Smart Box, data logger, web server
64-2006
OKO-AP_BL
Bold Line Air Pump max pressure 300 mbar
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
9
Bold Line Stage Top Incubator System
Complete systems include
• Incubating chamber
• Multichannel temperature controller
• Gas controller (CO2, O2, or dual CO2/O2)
• Humidity module
• Touch screen interface
• Smart box (optional)
Optional Smart Box
Oko-Touch
Suction
Outlet
Stage Top Incubation
The Bold Line stage top incubator system offers complete control over the
temperature, humidity, CO2/O2, with an easy-to-use touch screen interface.
Add an optional Smart Box and you have the ability to control and monitor
system performance via any web enabled device.
The advanced mechanical and thermal design of the incubating chambers
deliver superior performance and tremendous operational flexibility. The
H301- T UNIT BL is the temperature controller used with the Bold Line Stage
Incubator. The controller maintains control of the chamber main body, heated
glass cover, and humidity module. Temperature is accurately maintained
within 0.1°C from 3°C above ambient to 50°C.
Specimen / Chamber Feedback Operation
There are two ways to operate the system depending on which temperature
sensor is selected. In the specimen feedback mode, an external temperature
sensor is placed close to the sample in a reference well in the incubating
chamber . The advantage of this configuration is the precision of the
temperature control. In the chamber feedback mode, temperature control is
provided by a temperature sensor embedded in the incubation chamber.
Careful calibration at the factory insures that the sample is maintained at the
set temperature. The advantage of this second approach is ease of use.
The H301 controller includes a self calibration routine, this is designed to
improve the accuracy of the chamber feedback mode. The calibration routine
uses two external temperature sensors, one measures the temperature of the
lab while the other is introduced into a reference well near the sample. The
calibration routine is easily launched via the touch screen interface.
10
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Bold Line Stage Top Incubator System
A typical, complete system includes the
following components:
1. H301-T-UNIT-BL Bold Line Multichannel Temperature
controller
2. H301-HMTC-BL Heating collar for H301-BC
3. H301-BC Glass Bubbling Column
4. 2GF MIXER Manual CO2 - Manual Air
5. OKO-AP Air Pump
6. H301-EC-BL Climate Chamber universal
7. Specimen Holder
H-301-EC-BL Incubation Chamber
Fits in standard XY stages by replacing the universal 110 x 160 mm (K frame) insert
Incubating Chambers
The Bold Line stage top incubators are available for any xy / piezo insert. The
shape of the incubating chamber depends on the xy stage or piezo insert. To
ensure a perfect fit, several chambers are available. A cross reference guide is
available on page 13 to aid in selecting the right incubating chamber for your
stage.
Chamber features include:
•
Heated glass cover
•
Removable riser to allow positioning of the condenser close to the
specimen
•
Interchangeable specimen holders
•
Perfusion holes for inlet and outlet of tubes
•
Embedded Temperature sensors in glass cover, chamber body, and
humidity collar.
Gas Controller Options
Okolab Microscope Incubators can be used with Bold Line gas controllers or
with Manual gas mixers. Bold Line gas controllers are the most advanced
solution for gas control.
The Bold Line is an integrated system of modular controllers which
communicate with each other through built-in connectors. User interface is via
the OKO Touch a high-resolution color touch screen.
The Bold Line Controllers can be enriched with the Smart Box to
operate/monitor the system via web application and to log and manage the
data.
Manual mixers
Manual gas mixers employ floating ball flow meters to mix gas streams. No
feedback is present on gas concentration.
H-301-EC-ROUND-BL Incubation Chamber
Fits in XY stages with circular opening (ie Nikon T/Ti-S(S)R - and Olympus IX2-SFR)
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
11
Bold Line Stage Top Incubator System
Humidity Module
Humidifying the gas mixture before delivery to the climate chamber is an
important step. Pre-heating the gas helps prevent medium evaporation and
avoids water condensation on glass and plastic surfaces.
Heating collar with bubbling column
OKO-Touch
User interface to the Bold Line Controllers is via the OKO Touch, a highresolution color touch screen.
OKO-Touch connects to any one of the Bold Line Controllers, detects the
equipment available, and displays the pages and functions supported by the
equipment.
Smart Box (SM-BL)
The Smart Box enhances the Bold Line family by adding the following features:
• Data logger
• Web server
• Video streaming server
• Remote assistant
Data logger
The Smart Box acquires the status from the integrated bold line controllers and
stores them in a local, non volatile memory.
Examples of acquired and stored data are: set point temperature, specimen
temperature, base, cover and humidifying module temperature, CO2 / O2
concentration and set point, gas flow rate, etc.
Smart Box also stores maximum temperature and gas concentration deviation within
a certain time interval.
Data can be recalled via a web application (through internet connection of Smart
Box or direct Ethernet connection of Smart Box to PC).
Web Server
The Smart Box is a web server and can be connected to the internet via Wi-Fi, USB,
or via Ethernet. Once connected, it is possible to view the current status, as well as
control the integrated control units. For instance the set point can be remotely
modified.
12
Video Streaming Server
A standard Webcam can be connected to the Smart Box to send streaming
images in. This is particularly useful for online support and to monitor the lab
remotely.
Remote Assistant
Okolab supports its customers with online video assistance. Via the Smart Box,
the support team can be enabled to access the integrated controller units to
perform maintenance and trouble shooting.
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Stage Top Incubating Chambers
A typical complete system
Order #
Model Number
Description
64-1995
64-2000
64-2010
64-2011
64-2012
64-2015
64-2007
64-2008
64-1999
H301-T-UNIT-BL
CO2 Unit-BL
H301-BC
H301-HMTC-BL
H301-EC-BL
H301-EC-6MW
Oko-Touch
SM-BL
OKO-AP
Thermal controller, operates in both chamber and specimen feedback
CO2 Controller, controls both Air and CO2
Bubbling column
Humidifying Module Temperature
Universal electrically heated chamber. Fits into K-frame inserts
6-well plates holder
Touch screen display
Smart Box, data logger, web server
Air pump
Select the chamber that fits your XY stage or piezo insert
Order #
Mfr.
Model or Stage Opening
Incubating Chamber - Fixing tool
64-2012
64-2012 + 64-2061
64-2012 + 64-2060
64-2041
Leica
k-frame opening (110x160mm)
m-frame
150x150 mm opening
Super Z Galvo Stage SP5
H301-EC-BL
H301-EC-BL + MANSA
H301-EC-BL + DMSA
H301-EC-BL
64-2012 +64-2063
64-2014
64-2012 + 64-2066
or 64-2046 + 64-2065
64-2012 + 64-2067
64-2012 + 64-2067
Nikon
Ti-S-E / Ti-S-ER
Ti-S-E / Ti-S-ER + MCL Nano-Z100
H301-EC-BL + TIPA
H301-EC-MCLTi-BL
H301-EC-BL + IC-VICE-TI-SR (*)
H301-EC-ROUND-BL + H301-ECS-IX2SFR-TIS-SI-LT
H301-EC-BL + SAMPA
H301-EC-BL + SAMPA
64-2012
64-2012 + 64-2072 or
64-2046 + 64-2070
64-2012 + 64-2071
Olympus
64-2012
64-2012 + 64-2061
T/Ti-S(S)R or TE300
T/Ti-SP+T/Ti-SAM
Ti-SM (TS100)
k-frame opening (110x160mm)
IX2-SFR
CK40-MVR/ IX-MVR
H301-EC-BL
H301-EC-BL + IC-VICE-IX-SUSP (*)
H301-EC-ROUND-BL + H301-ECS-IX2SFR-TIS-SI-LT
H301-EC-BL + MVR-SA
Zeiss
k frame opening (110x160mm)
m-frame
H301-EC-BL
H301-EC-BL + MANSA
64-2012
64-2012
64-2012
64-2012
ASI
MS-2000
MS-2000 FT
PZ-2000
PZ-2000FT
H301-EC-BL
H301-EC-BL
H301-EC-BL
H301-EC-BL
64-2012
64-2012 + 64-2077
Ludl
BioPrecision2 - Biopoint 2 series
96A602 Piezo stage
H301-EC-BL
H301-EC-BL + XCR-FRAME-1
64-2012
Marzhauser
Scan IM series
H301-EC-BL
64-2012 + 64-2078
Phiab
M3 Stage
H301-EC-BL + PHIPA
64-2051
Physik Instrumente
P-737.2SL piezo
H301-EC-PI-BL
64-2012
64-2012 + 64-2079
64-2040
64-2013
Prior
H107 /ES 107
H117
NZ 100 and NZ 200
NZ 250 and NZ 500
H301-EC-BL
H301-EC-BL + XCR-FRAME
H301-EC-NZ100-BL
H301-EC-NZ500-BL
64-2012 + 64-2081
Thorlabs
Thorlabs MLS203-1 /MLS203-2
H301-EC-BL + THORPA
64-2055
Upright
Microscopes
Stages for any upright microscope
H301-EC-UP-BL
(*) select this chamber if you plan to use MW plates
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
13
Stage Top Multiwell Plate Specimen Holders
Specimen holders for motorized stages, compatible with
H301-EC-BL, H301-EC-NZ500-BL and H301-EC-MCLTi-BL
Order #
64-2015
64-2016
64-2017
64-2018
64-2019
64-2020
14
Model Number
H301-EC-6MW
H301-EC-12MW
H301-EC-24MW
H301-EC-24MW-NUNC
H301-EC-48MW
H301-EC-96MW
Description
6-well plate holder
12-well plate holder
24-well plate holder
24-well NUNC plate holder
48-well plate holder
96-well plate holder
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Stage Top Petri and Slide Specimen Holders
Specimen holders for motorized stages, compatible with H301-EC-BL, H301-EC-NZ500-BL and H301-EC-MCLTi-BL
Order #
64-2021
64-2022
64-2023
64-2024
64-2025
64-2026
64-2027
64-2028
64-2029
64-2030
64-2031
64-2032
64-2033
64-2034
Model Number
H301-EC-1x35
H301-EC-2x35
H301-EC-4x35
H301-EC-1xGS
H301-EC-2xGS
H301-EC-1x[57mm]GS
H301-EC-2x[57mm]GS
H301-EC-1x60
H301-EC-2x60
H301-EC-GS35
H301-EC-[57mm]GS35
H301-EC-3560
H301-EC-GS60
H301-EC-[57mm]GS60
Description
One 35mm Petri-dish holder
Two 35mm Petri-dish holder
Four 35mm Petri-dish holder
One standard chamber slide holder
Two standard chamber slides holder
One 57mm chambered coverglass holder
Two 57mm chambered coverglass holder
One 60mm Petri-dish holder
Two 60mm Petri-dish holder
One standard chamber slide and two 35mm Petri-dish holder
One 57 mm chambered coverglass and two 35mm Petri-dis holder
One 35mm and one 60 mm Petri-dish holder
One standard chamber slide and one 60mm Petri-dish holder
One 57 mm chambered coverglass and one 60mm Petri-dish holder
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
15
Specimen Holders for XY stages with circular insert
Specimen holders for motorized stages, compatible with H301-EC-BL, H301-ECNZ500-BL and H301-EC-MCLTi-BL
Order #
64-2035
64-2036
64-2037
64-2038
64-2039
64-2042
64-2043
64-2044
64-2045
64-2047
64-2048
64-2049
64-2050
64-2052
64-2053
64-2054
64-2056
64-2057
64-2058
64-2059
16
Model Number
H301-EC-GS35-ROUND
H301-EC-1x35-ROUND
H301-EC-1xGS-ROUND
H301-EC-1x[57mm]GS-ROUND
H301-EC-1x60-ROUND
H301-EC-LG-1x35
H301-EC-LG-1xGS
H301-EC-LG-1x[57mm]GS
H301-EC-LG-1x60
H301-EC-ROUND-1x35
H301-EC-ROUND-1xGS
H301-EC-ROUND-1x[57mm]GS
H301-EC-ROUND-1x60
H301-EC-PI-1x35
H301-EC-PI-1xGS
H301-EC-PI-1x[57mm]GS
H301-EC-UP-1x35
H301-EC-UP-1xGS
H301-EC-UP-1x[57mm]GS
H301-EC-UP-1x60
Description
One standard chamber slide and one 35mm Petri-dish holder for flat stages with circular insert
One 35mm Petri-dish holder. Suitable for flat stages with circular insert
One standard chamber slide holder. Suitable for flat stages with circular insert
One 57mm chambered coverglass holder. Suitable for flat stages with circular insert
One 60mm Petri-dish holder. Suitable for flat stages with circular insert
One 35mm Petri-dish holder
One standard chamber slide holder
One 57mm chambered coverglass holder
One 60mm Petri-dish holder
One 35mm Petri-dish holder
One standard chamber slides holder
One 57mm chambered coverglass holder
One 60mm Petri-dish holder
One 35mm Petri-dish holder
One standard chamber slides holder
One 57mm chambered coverglass holder
One 35mm Petri-dish holder
One standard chamber slides holder
One 57mm chambered coverglass holder
One 60mm Petri-dish holder
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Fixing Tools
Order #
Model Number
64-2060
DMSA
64-2061
MANSA
64-2062
H301-EC-LG-DMIRE2-SI
64-2063
NIKON
TIPA
Description
Required for 150 x150mm opening XY stages adapts H101-WJC, H101-WJC-SLIM,
H201-MEC-SLIM and H301-EC-BL into 150 x150mm opening stages.
Required for M-frame stages, adapts H101-WJC, H201-MEC-SLIM and H301-EC-BL into M-frame
stages.
Adapts H301-EC-LG-BL into 150 x150mm opening XY stages. Convenient if you have two different
microscopes, one equipped with the SP5 Super Z galvo stage and the other one equipped with the
150 x150mm opening stage and want to use the same incubator on both set-ups.
64-2080
Required for TI-S-E(-R) motorized XY stages, allows H101-WJC, H101-WJC-SLIM, H201MEC-SLIM and H301-EC-BL to fit into TI-S-E(-R) motorized XY stages.
H201-MEC-FST-SI-L
Required for T/Ti-S(S)R rectangular stages with circular opening, allows H201-MEC-ROUND
to fit on T/Ti-S(S)R rectangular stages.
H301-ECS-IX2SFR-TIS-SI-LT Required for T/Ti-S(S)R rectangular stages with circular opening, allows H301-EC-ROUND-BL
to fit on T/Ti-S(S)R rectangular stages.
IC-VICE-TI-SR
Adapts H101-WJC, H101-WJC-SLIM, H201-MEC-SLIM, H301-EC-BL and UNO on T/Ti-S(S)R
rectangular stages with circular opening.
SAMPA
Required for TI-SM and T/Ti-SP+T/Ti-SAM mechanical stages. Adapts H301-EC-BL on TI-SM stages
and H201-MEC-SLIM and H301-EC-BL on T/Ti-SP+T/Ti-SAM stages.
SAMPA-2
Required for T/Ti-SP+T/Ti-SAM mechanical stages. Adapts H101-WJC on T/Ti-SP+T/Ti-SAM stages.
H301-EC-PZ100-CI-108
Adapts H301-EC-NZ100-BL or H201-MEC-NZ100 on T/Ti-S(S)R rectangular stages. Convenient if
you have two different microscopes, one equipped with the Prior NZ100/NZ200 Nano Scan Z stage
and the other one equipped with the T/Ti-S(S)R rectangular stage with circular opening and want to
use the same incubator on both set-ups.
OLYMPUS
H301-ECS-IX2SFR-TIS-SI-LT Required for IX2-SFR cross stages. Adapts H301-EC-ROUND-BL on IX2-SFR cross stages.
MVR-SA
Required for IX2-KSP+CK40-MVR/IX2-SP+IX-MVR mechanical stages. Adapts H201-MECSLIM and H301-EC-BL on IX2-KSP+CK40-MVR/IX2-SP+IX-MVR mechanical stages.
IC-VICE-IX-SUSP
Adapts H101-WJC, H101-WJC-SLIM, and H301-EC-BL on IX2-SFR cross stages.
H501-IX-SUSP
Adapts UNO on IX2-SFR cross stages.
H301-EC-PZ100-CI-110
Adapts H301-EC-NZ100-BL on IX2-SFR or IX-SVL2 cross stages. Convenient if you have two different
microscopes, one equipped with the Prior NZ100/NZ200 Nano Scan Z stage and the other one
equipped with the IX2-SFR or IX-SVL2 cross stage and want to use the same incubator on both setup.
ZEISS
MANSA
Required for M-frame stages. It allows to fit H101-WJC, H201-MEC-SLIM and H301-EC-BL into Mframe stages.
APPLIED PRECISION
H201-MEC-FST-DV-SI
Required for 51-603288-000 Deltavision Stage. Adapts H201-MEC-ROUND into 51-603288-000
Deltavision Stages.
LUDL
XCR-FRAME-1
Required for 96A602 large aperture Piezo stages. Adapts H301-EC-BL into 96A602 large aperture
Piezo stages.
PHIAB
PHIPA
Required for M3 stages. Adapts H301-EC-BL into M3 stages.
PRIOR
XCR-FRAME
Required for H117 motorized XY stages, fits H101-WJC and H301-EC-BL into H117
motorized XY stages.
XCR-FRAME-WS
Required for H117 motorized XY stages, fits H101-WJC-SLIM into H117 motorized XY stages
64-2081
THORLABS
THORPA
64-2082
THORPA-2
64-2083
OTHERS
PZ100-SA
64-2064
64-2065
64-2066
64-2067
64-2068
64-2069
64-2070
64-2071
64-2072
64-2073
64-2074
64-2075
64-2076
64-2077
64-2078
64-2079
Required for MLS203-1 and MLS203-2 motorized XY stages. Adapts H301-EC-BL into MLS203-1
and MLS203-2 motorized XY stages.
Required for MLS203-1 and MLS203-2 motorized XY stages. Adapts H201-MEC-SLIM into MLS2031 and MLS203-2 motorized XY stages.
Adapts H301-EC-NZ100-BL or H201-MEC-NZ100 on all XY stages that mount K-frame inserts.
Convenient if you have two different microscopes, one equipped with the Prior NZ100/NZ200 Nano
Scan Z stage and the other one equipped with a K-frame XY stage and want to use the same
incubator on both set-ups.
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
17
Bold Line Cage Incubator
Complete systems include
•
•
•
•
•
•
•
•
•
Microscope enclosure
Stage top climate chamber
Temperature controller with air heater
Gas controller (CO2, O2, or dual CO2/O2)
Humidity module
Touch screen interface
Smart box (optional)
Obscuring panels (optional)
Filter box (optional)
Bold Line Microscope Enclosure
A controlled environment all around the microscope.
The CO2 Microscope Cage Incubator is designed to maintain the required
environmental conditions for cell culture around your microscopy workstation,
enabling prolonged observations on biological specimens and allowing space
for other equipment.
Cells cultured within the microscope cage incubator have been shown to
proliferate as well as in a regular bench-top incubator.
Models for any inverted and upright microscope are available. A wide choice
of chambers and interchangeable plate adapters allow the use of any cell
culture support (petri, glass slides, multiwell plates, and others). Compatible
with manual and digital CO2 / O2 gas controllers.
Easy 'turn-to-open' assembly
'Turn-to-open' hinges permit direct removal of both the front and upper panel.
Once these panels have been removed, the rest of the cage incubator can be
easily moved backwards. When needed, the cage incubator can be
reassembled in five minutes.
Full accessibility
Several doors on the front and side panels allow full and easy access to the
microscope. In particular, two openings on the bottom of the front panel
provide unrestricted access to the focus knob.
Additional doors can be added upon request.
Obscuring Panels
Obscuring panels can be assembled with the cage by means of turn to open
hinges to create a darkeded environment for fluorescence experiments.
18
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Bold Line Cage Incubator
Touch Screen, Temperature Controller and Optional Smart Box
Air Heater with filter
Temperature Controller - H201 T UNIT BL
The H201 T UNIT BL is the temperature controller used with the cage
incubator, it includes the air heater, and requires the Oko-Touch for
operation.
The controller keeps the specimen at the desired temperature by
maintaining the temperature of the air blown into the enclosure. A
filter box can be attached to the air heater to guarantee that the
recycled air is dust and bacteria free. Temperature precision is 0.1°C
from 3°C above ambient to 40°C.
The air heater has a double inlet and outlet to recycle the heated air.
Flow rate and temperature sensors are continuously monitored and
allow fast start- up and stable gradient free operation during the
experiment. Air flow rate and temperature are set using the OKOTouch.
Specimen / Cage Temperature feedback operation
There are two ways to operate the system depending on which
temperature sensor is used to provide feedback to the H201 - T UNIT
BL.
In the specimen feedback mode, feedback is provided by a sensor
placed inside the climate chamber near the specimen. Simple
manipulation is required to attach the thermocouple into the reference
well with adhesive tape.
In the enclosure feedback mode the sensor is measuring the
temperature of the air inside the enclosure.
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
19
Cage Incubator Climate Chamber
Climate Chamber for local CO2 and humidity conditioning
A controlled environment all around the microscope.
The climate chamber fits into the microscope XY stage or piezo inserts and hosts the sample. It creates a small volume inside the cage enclosure in
which the pre-mixed and pre-humidified stream of air and CO2 is continously fed.
•
•
•
•
•
Chambers available for any XY stage / piezo insert
Slim profile allows proper placement of the condenser
Interchangeable specimen holders
Perfusion holes for inlet and outlet of tubes
External temperature sensor
H-201-MEC-SLIM
20
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Cage Incubator CO2 - O2 - Humidity Control
The Bold Line Cage Incubator can be equipped with Bold Line gas controllers or with Manual gas mixers
Bold Line Gas Controllers
Manual Gas Mixers
•
•
•
•
• Set point resolution 1%
• Works with any microscope incubator
• CO2 concentrations in the 0-15% range
Highest accuracy and repeatability
Digital CO2 and Air / N2 controller
Operated via OKO-Touch
Compatible with Smart Box
Digital gas mixers
CO2 %
O2 %
CO2 UNIT BL
0-18
-
O2 UNIT BL 1-20
-
1-20
CO2-O2 UNIT BL [0-10;1-18]
0-10
1-18
CO2-O2 UNIT BL [0-20;1-95]
0-20
1-95
CO2-O2 UNIT BL - CP
4-8
3-7
Manual gas mixers
CO2 %
O2 %
2GF-Mixer
0-20
-
3GF-Mixer-Hypoxia
0-15
2-20
3GF-Mixer-Hyperoxia
0-15
40-85
Humidity Module
Mixed gas is humidified by bubbling through a glass column containing
distilled water. The bubbling column is placed inside the temperature
controlled enclosure to saturate the gas stream at the same temperature as
the specimen.
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com 21
Bold Line Cage Incubator
Order #
Model Number
64-2101
H201
64-2102
64-2103
H201-OP
H201-T-UNIT-BL
64-2007
64-2008
64-2104
64-2105
64-2106
64-2107
Oko-Touch
SM-BL
H201-T-FILTER-BOX
H201-FILTER KIT
H201-BC
H201-MEC-SLIM
64-2108
H201-MEC-XCR
64-2109
H201-MEC-NZ500
64-2110
H201-MEC-ASI
64-2111
H201-MEC-A602
Description
Lexan Microscope Enclosure. Suitable for both inverted and upright microscopes. Same part
number and price for all microscopes. Details and photos to specify the exact configuration of
your scope will be needed at time of order
Obscuring panels. They can be added to the lexan enclosure to create a dark environment
Temperature contol unit - Bold Line. Operated by the OKO-Touch. Can be equipped with the
Smart Box for data-logging, remote operation and remote support
Touch screen display
Smart Box, data logger, web server
HEPA filtering unit
Filter Kit (spare part)
Bubbling column. Humidifies the gas stream before the inlet into the chamber.
Universal Climate chamber. Fits into K-frame inserts. Check Fixing Tools sheet for
the compatibility with other XY stages, accommodates 6-12-24-48-96 multiwell plates. For other
supports, add the corresponding specimen holder
Climate chamber for Prior H117 motorised XY stage, accommodates 6-12-24-48-96 multiwell
plates. For other supports, add the corresponding specimen holder
Climate chamber for Prior NanoScan Z-stage NZ250 and NZ500, accommodates
6-12-24-48-96 multiwell plates. For other supports, add the corresponding specimen holder
Climate chamber for ASI stage, accommodates 6-12-24-48-96 multiwell plates.
For other supports add the corresponding specimen holder
Climate chamber for Ludl 96A602 Large Aperture Piezo stage, accommodates 6-12-24-48-96
multiwell plates. For other supports, add the corresponding specimen holder
Specimen holders compatible with H201-MEC-SLIM; H201-MEC-XCR; H201-MEC-NZ500, H201-MEC-ASI and H201-MEC-A602
22
Order #
Model Number
Description
64-2112
64-2113
64-2114
64-2115
64-2116
64-2117
64-2118
64-2119
64-2120
64-2121
64-2122
H201-MEC-1xGS2x[57mm]GS
H201-MEC-GS35
H201-MEC-GS60
H201-MEC-6035
H201-MEC-4x35
H201-MEC-3xGS
H201-MEC-2x60
H201-MEC-1x35
H201-MEC-1xGS
H201-MEC-1x[57MM]GS
H201-MEC-1x60
One standard chamber slide and two 57mm chambered coverglass holder
Two standard chamber slide and two 35mm Petri-dish holder
One standard chamber slide and One 60mm Petri-dish holder
One 60mm Petri-dish and two 35mm Petri-dish holder
Four 35mm Petri-dish holder
Three standard chamber slide holder
two 60mm Petri-dish holder
One 35mm Petri-dish holder
One Standard chamber slide holder
One 57mm chambered coverglass holder
One 60mm Petri-dish holder
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
Bold Line Cage Incubator
Specimen holders compatible with H201-MEC-SLIM; H201-MEC-XCR; H201-MEC-NZ500, H201-MEC-ASI and H201-MEC-A602
Order #
Model Number
Description
64-2123
H201-MEC-ROUND
64-2124
64-2125
64-2126
64-2127
64-2128
64-2129
64-2130
64-2131
H201-MEC-ROUND-2x35
H201-MEC-ROUND-2xGS
H201-MEC-ROUND-2x[57mm]GS
H201-MEC-ROUND-1x35
H201-MEC-ROUND-1xGS
H201-MEC-ROUND-1x[57MM]GS
H201-MEC-ROUND-1x60
H201-MEC-NZ100
64-2132
H201-MEC-MCLTi
64-2133
H201-MEC-LG
64-2134
64-2135
64-2136
64-2137
64-2138
64-2139
64-2140
64-2141
64-2142
64-2143
64-2144
64-2145
64-2146
64-2147
64-2148
64-2149
64-2150
64-2151
64-2152
H201-MEC-LG-MW
H201-MEC-LG-GS35
H201-MEC-LG-[57mm]GS35
H201-MEC-LG-4x35
H201-MEC-LG-3xGS
H201-MEC-LG-2x[57mm]GS
H201-MEC-LG-1x35
H201-MEC-LG-1x60
H201-MEC-SP2
H201-MEC-SP2-2x35
H201-MEC-SP2-2xGS
H201-MEC-SP2-2x[57mm]GS
H201-MEC-SP2-2x60
H201-MEC-PI
H201-MEC-PI-GS35
H201-MEC-PI-GS60
H201-MEC-PI-1x35
H201-MEC-PI-1x60
H201-MEC-UP
64-2153
64-2154
H201-MEC-UPRIGHT-LID-F
H201-MEC-UPRIGHT-LID-WIMM
64-2155
H201-MEC-UPRIGHT-LID-MM
64-2156
64-2157
64-2158
64-2159
H201-MEC-UP-1x35
H201-MEC-UP-1xGS
H201-MEC-UP-1x[57mm]GS
H201-MEC-UP-1x60
Climate chamber for mechanical flat XY stage with circular opening (i.e. Nikon
T/Ti-SR and T/Ti-SSR & Olympus IX2-SFR ), accomodates 6-12-24-48-96
multiwell plates. For other supports, add the corresponding specimen holder
Two 35mm Petri-dish holder. Circular bottom shape
Two standard chamber slides holder. Circular bottom shape
Two 57mm chambered coverglass holder. Circular bottom shape
One 35mm Petri-dish holder. Circular bottom shape
One standard chamber slide holders. Circular bottom shape
One 57mm chambered coverglass holder. Circular bottom shape
One 60mm Petri-dish holder. Circular bottom shape
Climate chamber for Prior NanoScan Z-stage NZ100 and NZ200,
accommodates one 35mm Petri-dish or one chamber slide
Climate chamber for Mad City Labs Nano-Z100-N Piezo stage on Nikon TI-S-E(-R)
XY stage and for Physik Instrumente P-736K003 on Nikon TI-S-E(-R) XY stage. It
does NOT require Okolab specimen holder since it uses same holders
provided with the piezo
Climate chamber Leica SP5 Super Z Galvo Stage. It requires at least one
specimen holder
Multiwell plate holder
Two standard chamber slide and two 35mm Petri-dish holder
Two chambered coverglass and two 35mm Petri-dish holder
Four 35mm Petri-dish holder
Three standard chamber slide holder
Two 57mm chambered coverglass holder
One 35mm Petri-dish holder
One 60mm Petri-dish holder
Climate chamber Leica SP2 Galvo Stage
Two 35mm Petri-dish holder
Two standard chamber slide holder
Two 57mm chambered coverglass holder
Two 60mm Petri-dish holder
Climate chamber for Physik Instrumente P-737.2SL piezo
Two 35mm Petri-dish and Two standard chamber slide holder
One 60mm Petri-dish and one standard chamber slide holder
One 35mm Petri-dish holder
One 60mm Petri-dish holder
Climate chamber for upright microscopes. Allows the use of dipping lens.
Requires at least one LID and one specimen holder
Flat lid for long distance objectives.
Lid for immersion objectives. Made up of two parts: one part rests on the
main body, while the upper part has a hole for objective insertion. The top part
can slide on the fixed part, allowing movement of the H201-MEC-UPRIGHT.
Flat sliding lid. Suitable to use H201-MEC-UPRIGHT along with
MicroManipulators.
One 35mm Petri-dish holder
One standard chamber slide holder
One 57mm chambered coverglass holder
One 60mm Petri-dish holder
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com 23
T Plates
Flat surface at controlled temperature - models available for any microscope
•
•
•
•
Suitable for inverted microscopes
Ideal for short term experiments
Glass and metal versions available
Touch screen interface temperature controller
T GLASS PLATE
A round heated plate with built-in temperature sensor fits into microscope XY
stages with circular openings and provides a transparent surface at controlled
temperature.
The conductive glass has a built in temperature sensor and when coupled with
the PID temperature controller provides precise control of specimen
temperature.
CONTROLLER
Controller features
• External Temperature Sensor (for Self Calibration Routine)
• Self Calibration Routine
• Two Temperature Channels (Built in Temperature Sensor and External
Temperature Sensor)
• Zero Footprint, if attached with supplied suspension brackets
Technical Specifications
Self Calibration Routine
Glass thickness
Temperature range
Temperature sensor accuracy
Temperature accuracy on specimen
Plate Diameter
Sensor
Calibration routine
User interface
(Optional)
Data Logger
The self calibration is performed by placing the External Temperature Sensor
into a Petri placed on the Plate and by selecting Self Calibration from the Touch
Screen. The controller will adjust the temperature of the Plate in order to keep
the specimen at 37°C.
24
1 mm
ambient to 40°C
±0.1°C
±0.3°C
108 or 110 mm
External Sensor for Calibration
Auto
3, 2’’ Touch Screen Controller
RS232
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
T Plates
H401-HG-R108 in self calibration
H401-HG-R108 on Nikon stage
Set point page
Warm metal plate for Zeiss Primo Star
Home page
Settings page
K-Frame Heated Insert
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com 25
T Glass Table
Transparent flat surface at controlled temperature for stereo microscopes
•
•
•
•
Suitable inverted microscopes
Ideal for short term experiments
Glass and metal versions available
Touch screen interface temperature controller
Glass Table
The Heated Table fits on any stereomicroscope and provides a temperature
controlled, transparent, and flat surface where the specimen can be placed.
The built-in temperature sensor measures glass surface temperature and
provides feedback to the PID controller.
The Table has two sets of supports, each with adjustable height. The 2 mm
thick heated surface can be positioned from the bench top from 33 to 46 mm
(with short supports) or from 80 to 110 mm (with tall supports).
Controller
The system is equipped with a modern PID controller with a 3.2’’ Touch Screen interface
that offers accuracy and ease of use.
Controller features
• External Temperature Sensor (for Self Calibration Routine)
• Self Calibration Routine
• Two Temperature Channels (Built in Temperature Sensor and External Temperature
Sensor)
Options
Data Logger
The Data Logger logs up to four T GLASS PLATES via RS232. It is equipped
with a Ethernet port for internet connection. Data are stored in local memory
and can be downloaded via a Web Application or via direct connection of the
data logger with a PC.
Gas Conditioning
CO2/O2 and humidity control can be achieved by using the Conditioning Jar and
one of the Okolab Gas Controllers.
A small amount of gas at the desired CO2 and O2 level will be blown by the
Gas Controller in the Jar to create a microenvironment at the desired
temperature and gas concentration. A water reservoir can be inserted into the
jar to reduce medium evaporation.
Technical Specifications
Glass thickness
Temperature range
Temperature sensor accuracy
Temperature accuracy on specimen
Table Dimensions
Observation area
Table height
• Zero Footprint, if attached with supplied suspension brackets
Self Calibration Routine
Self calibration is performed by placing the External Temperature Sensor into a Petri
placed on the plate and by selecting Self Calibration from the Touch Screen. The controller
will adjust the temperature of the Plate in order to keep the specimen at 37°C.
26
Sensor
Calibration routine
User interface
(Optional)
Data Logger
2 mm
ambient to 40°C
±0.1°C
±0.3°C
400 x 225 mm
180 x 100 mm
adjustable in the ranges 30 - 46 mm or
80 – 110 mm
External Sensor for Calibration
Auto
3, 2’’ Touch Screen Controller
RS232
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
T Glass Table
H401-HG-SMU with stereomicroscope
H401-HG-SMU with short supports height 30-46 mm
H401-HG-SMU with tall supports height 80-110 mm
Gas Conditioning Jar
H401-GCC -3019 &SFM
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
27
T Plates
Order #
28
Model Number
64-2084
H401-T
64-2085
64-2087
64-2088
64-2089
H401-KF
H401-R110
H401-PZ100
H401-CZPS
64-2090
64-2091
64-2092
64-2093
64-2094
H401-DMIL
H401-R80
H401-SA
H401-CA88
H401-CA110
64-2095
H401-HG0.5-R108
64-2096
H401-HG1-R108
64-2097
H401-HG0.5-R110
64-2098
H401-HG1-R110
64-2099
H401-HG-KF
64-2100
H401-HG-SMU
Description
Controller
Warm Plate Temperature Controller. This unit controls warm plate temperature. Operating range: 3°C above
ambient to 50°C. 24 V DC.
Metal Plates
Warm plate for K-frame inserts. It fits in microscope stages with 160x110mm XY stage insert
Round Warm Plate. For stages with R110mm insert (OLYMPUS).
Warm Plate for Prior Piezo Stage. It fits in Prior Nanoscan NZ100 and NZ200. It hosts one 35mm Perti.
Warm Plate for Zeiss Primo Star. It fits on the manual stage of Zeiss Primo Star. It hosts one 35mm Perti or one
glass slide.
Warm Plate for Leica DMIL. It fits into the Leica DMIL manual stage and hosts one 35mm Perti.
Round Warm Plate. It fits in microscope stages with 80mm circular central hole.
Stage adapter to accommodate H401-R80 in microscope stages with rectangular insert (160x110mm).
Adapter to accommodate H401-R80 in stages with 88mm circular central hole.
Adapter to accommodate H401-R80 in stages with 110mm circular central hole.
Glass Plates
Heated Glass Round insert for mechanical stages with 108mm circular insert (Nikon). Glass Thickness 0.5 mm.
Includes glass round insert and temperature controller.
Heated Glass Round insert for mechanical stages with 108mm circular insert (Nikon). Glass Thickness 1 mm. It
Includes: glass round insert and temperature controller.
Heated Glass Round insert for mechanical stages with 110mm circular insert (Olympus). Glass Thickness 0.5 mm.
Includes: glass round insert and temperature controller.
Heated Glass Round insert for mechanical stages with 110mm circular insert (Olympus). Glass Thickness 1 mm. It
Includes: glass round insert and temperature controller.
Heated Glass insert for XY stages with K-frame insert. Includes: glass rectangular 160x110mm insert and
temperature controller.
Heated Glass Table
Heated Glass Universal Table for stereomicroscopes. Includes: glass table and temperature controller.
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
UNO CO2 Microscope Stage Incubator
• Long term experiments at low cost
• Fits microtitre plate holders
• Designed for high magnification microscopy
• Temperature control from ambient (+3°C) to 50°C
• Support for 35 mm dishes and slides
Versatile Design
The UNO Microscope Stage Incubator uses interchangeable plate adapters to
accept a single 35 mm Petri dish, a glass slide, or chambered 57 mm cover
glass.
Temperature Regulation
Specimen temperature is regulated by the combined action of dual controllers
embedded in the base and the lid of the incubating chamber. Operation is
simple: Just select the desired plate adapter and the desired sample
temperature.
Humidity Regulation
An improperly humidified gas stream will quickly evaporate the media
surrounding the sample. The UNO controller automatically adjusts the
temperature in the humidifier to correct for evaporative losses.
CO2 Regulation
The built-in, manual CO2 controller continuously mixes air and CO2, this stream
is fed into the incubating chamber to control the pH of the media.
Technical Specifications
Temperature Range
Accuracy
Heating Technology
Type of Controller
Temperature feedback
CO2 range
Physical Dimensions:
(L x W x H)
Weight
Minimum condenser working distance
Perfusion ports
Ambient (+3°C) to 45°C
±0.3°C
Electric
Hardware
Chamber temperature feedback
0 to 15%
85.5 x 127.5 x 25.0 mm
310 g
23 mm
12 (I.D. 2.5 mm)
Ordering Information
Cat. No.
64-2196
64-2197
64-2198
64-2199
64-2200
64-1999
Model
UNO
UNO -EC-1X35
UNO -EC-1XGS
UNO -EC-1X[57mm]GS
UNO -TS
OKO-AP
Product
Complete CO2 stage incubator
35 mm Petri dish plate adapter
1x3” chamber slide plate adapter
1x2” chamber slide plate adapter
Software
Air Pump
Warner Instruments Inc. • Phone (203) 776-0664 • Toll Free U.S. (800) 599-4203 • Fax (203) 776-1278 • www.warneronline.com
29
1125 Dixwell Avenue
Hamden, CT 06514 USA
203-776-0664 • 800-599-4203
Fax 203-776-1278
www.warneronline.com
email: sales@warneronline.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising