Air to Water Catalogue (WATERSTAGE)

Air to Water Catalogue (WATERSTAGE)
Innovative Solution of Domestic Heating
Split type
Split DHW Integrated type
Monobloc type
Fujitsu General “Waterstage” heat pumps are very efficient,
regenerative and varied central heating systems,
which absorb the energy mainly from the air.
21 Models
INDEX
04 OVERVIEW
08 USAGE INTRODUCTION
16 PRODUCT TECHNOLOGY &
FEATURES
22 PRODUCT LINEUP
What’s a Heat Pump ?
1 kWh
Absorbing the free energy from atmosphere.
Heat pump system requires only 1 kW of electricity to generate 3 to 5 kW thermal energy.
3 to 5 kWh
Heat Pump system framework
of heat
Electricity
Outdoor unit
Heat
Comfort heating
Expansion
valve
Heat
Heat absorption
Compressor
2 to 4 kWh
Ambient air
Heat
Primary Energy Usage Reduced Drastically!
Proportion of primary energy into heating energy of 100%
Indoor unit
Primary Energy Consumption*
Heat
Heat
Heat
Emitter Heat
Heat
Heat
Direct electrical heating
278%
Fuel boiler
117%
Energy
heating
Gas condensing boiler
109%
100%
SPLIT TYPE
SPLIT DHW INTEGRATED TYPE
MONOBLOC TYPE
34 SYSTEM CONFIGURATION &
OPTIONAL PARTS
46 OTHERS
SIMPLE INSTALLATION & MAINTENANCE
INSTALLATION INFORMATION
SPECIFICATIONS & DIMENSIONS
MODEL SELECTION SOFTWARE
79%
*Electricity loss is different due to power plant. Example efficiency of power plant: 36%
2
3
OVERVIEW
Advantage
Wide Comfort
Energy Efficiency standard
Advantage
Less
Low
CO2 Emissions
Running Cost
This environmentally-friendly system substantially reduces
CO2 emissions compared to conventional gas and hydro
carbons combustion.
Running cost is low and economical by high efficiency heat
pump technology.
Average annual CO2 emissions
Average annual running cost
Direct electric heating
Direct electric heating
Fuel boiler
Fuel boiler
Gas condensing boiler
Gas condensing boiler
0
50
100%
*The values may vary depending on installation, location, and operating
conditions.
*Calculations based on data provided by European Program-2001` for EU 27
Fuel boiler efficiency: 89%, Gas boiler efficiency: 93%
Clean
and Healthy
Since burners are unnecessary, NOx and other harmful
substances are not generated.
Environmentally friendly
heating system
Easy
Installation and Maintenance
All components are built into compact outdoor unit or
hydraulic indoor unit.
No
chimney
sweep
No
pollution
Low
maintenance
cost
Well structured Hydraulic indoor unit.
Sophisticated arrangement of hydraulic units, allows easy
piping and maintenance
4
5
OVERVIEW
Energy Efficiency standard
Product labels
For Space heaters
For Combination heaters
Product identifier
Trade mark
Symbol for space heating
Scale of efficiency
class, from A++ (highest
efficiency) to G (lowest efficiency)
Sound power level outdoors
and (where relevant)
indoors
Year when label issued
Efficiency class in low
temperature operation
Symbol for hot water
heating
Efficiency class in medium
temperature operation
Scale of efficiency class,
from A (highest efficiency)
to G (lowest efficiency) for
hot water heating
Temperature map of
Europe with three climate
zones and the rated heat
output of each
Optional symbol where
operation is possible only
in off-peak periods
Number of EU regulation
The Ecodesign Directive Lot1 Regulation 813/2013
New Ecodesign directive defines a regulatory framework for improving the
environmental performance of energy-related products(ErP)through design.
From 26 September 2015, the Ecodesign Directive will apply to space
heaters(including heat pumps and fossil fuel boilers), combination heaters(for
both space and water heating),water heaters and water storage tanks.
All these products will have to meet minimum requirements for energy
efficiency* and maximum sound power levels.The minimum energy efficiency
level will be raised from 26 September 2017 and maximum sound power level
will be lowered on 26 September 2018.
Wide Comfort
The clean energy delivers “comfort” to all spaces in the home up to the living
room, bedrooms, bath and swimming pool.
Solar connection
DHW tank
Hydraulic unit
Room
Heating
Energy efficiency class
Except low temp HP
55˚C
low temp HP
35˚C
ηs ≥ 150
ηs ≥ 175
125 ≤ ηs < 150
150 ≤ ηs < 175
98 ≤ ηs < 125
123 ≤ ηs < 150
*Energy efficiency is represented by seasonal space heating efficiency(ηs). This value is based upon the
seasonal coefficient of performance(SCOP).
90 ≤ ηs < 98
115 ≤ ηs < 123
82 ≤ ηs < 90
107 ≤ ηs < 115
The Energy Labelling Directive (EU)No 811/213
75 ≤ ηs < 82
100 ≤ ηs < 107
36 ≤ ηs < 75
61 ≤ ηs < 100
34 ≤ ηs < 36
59 ≤ ηs < 61
30 ≤ ηs < 34
55 ≤ ηs < 59
ηs < 30
ηs < 55
The energy label aims to help consumers make direct comparisons of energy
use, as well as product specific features. On all labels, product identifier,
efficiency class, sound power levels and heat output must be displayed. For heat
generators, the scale runs from A++ to G(A+++ to D from 2019). There are two
different product labels for space heaters and combination heaters.
Domestic
Hot Water
Outdoor unit
Swimming
Pool
Cooling
EHPA Quality label
FUJITSU GENERAL`s WATERSTAGE* have
obtained the EHPA Quality Label** by tests
according to the international Standards
EN14511 and EN17025. The EHPA Quality
Label** is a label that shows the endconsumer a quality heat pump unit on the
market.
*: High Power split model
**: Check the validity of label at www.ehpa.org/QL
6
Seasonal space heating
SG-Ready Label
SG-Ready is a defined standard by BWP***, which makes
it possible that the device can be integrated into a smart
grid. Heat pumps, which are equipped with the SG-Ready
Label, can receive signals from the power grid (and
e.g. also from PV systems) about the available (unused
renewable) energy (from wind, sun & water). Fujitsu
General provides the SG-Ready compatibility to all new
Heat Pumps series.
***BWP: the Federal German Heat Pump Association
7
USAGE
INTRODUCTION
Wide range lineup suited for regional characteristics, family structure, and application
We provide various products to meet your needs from High Power via heating-centered
series to reasonably-priced compact series
Outdoor
temperature
-25°C
Outdoor
temperature
-20°C
Cold district
Split type with separate outdoor unit and hydraulic indoor unit
For details, see page 10-11, 24-27
High Power
series
Comfort
series
Heat up
Hydraulic
indoor
unit
Heat up
Hydraulic
indoor
unit
DHW Tank 190 L
DHW Tank 190 L
Outdoor unit
Outdoor unit
Split type with DHW tank built-in hydraulic indoor unit
For details, see page 12-13, 28-31
High Power
series
Comfort
series
Heat up
Hydraulic
indoor
unit
Heat up
Hydraulic
indoor
unit
DHW Tank 190 L
DHW Tank 190 L
Outdoor unit
Outdoor unit
All-in-one type without refrigerant piping work
For details, see page 14-15, 32-33
Compact
series
Heat up
Hydraulic
indoor
unit
Outdoor unit
8
9
USAGE INTRODUCTION
Hydraulic indoor unit
All-in-one indoor unit
24-27 page
Outdoor units
For cold regions
High Power series
Room
heating
& Domestic hot water
24-25 page
Compact design
Comfort series
26-27 page
DHW Tank
(Option)
• Outdoor unit and hydraulic indoor unit can be installed freely, so installation is easy.
• Since hydraulic indoor unit is installed inside a house, freezing of circulated water can be prevented.
• A larger heating capacity can be performed flexibly by using more units in cascade connection.
+ Boiler
+ DHW Tank
By combining existing boiler, powerful
heating can be performed even at low
outdoor temperature.
DHW tank (option) can be used to supply hot
water by connecting it to the system.
300 Liter
10
11
USAGE INTRODUCTION
Hydraulic indoor unit
All-in-one indoor unit
28-31 page
Outdoor units
For cold regions
High Power series
28-29 page
Compact design
Comfort series
Room heating
& Domestic
hot water
30-31 page
• Space is saved drastically due to built-in DHW tank.
• Existing boiler can be replaced easily.
• A larger heating capacity can be performed flexibly by using more units in cascade connection.
Stylish space saving solution
with built-in DHW tank
Hydraulic indoor unit
12
DHW tank 190 L
13
USAGE INTRODUCTION
Hydraulic indoor unit
Smart installation
32-33 page
Outdoor units
All in one model
32-33 page
DHW Tank
(Option)
Simple setting
Room heating
& Domestic hot water
• Outdoor unit and hydraulic indoor unit can be installed anywhere due to compact size.
• Installation work can be performed easily only by connecting hydraulic pipes.
• DHW tank can be connected to indoor side.
Compact Design
Weight
49 kg
By combining existing boiler,
powerful heating can be performed
even at low outdoor temperature.
675 mm
5 kW model
+ DHW Tank
300 mm
825 mm
14
+ Boiler
DHW tank (option) can be
used to supply hot water by
connecting it to the system.
300 Liter
15
PRODUCT
TECHNOLOGY
&
FEATURES
16
17
PRODUCT TECHNOLOGY
Twin Rotary Compressor
High Durability Co-axial Heat Exchanger
Stainless steel
buffer tank
Warm
refrigerant flow
Linear Control Injection Port
• Corrosion protected
• No flow switch necessary
• Anti-freeze-protection is unnecessary
Heated water
Optimum Co-axial
Heat Exchanger
Product technology for Outdoor Unit
Twin Rotary Compressor
Accurate temperature control
by DC inverter technology
with Linear Control Injection Port
Optimized circuit =
higher water temperature
Co-axial
Heat
Exchanger
V-PAM inverter
technology
Linear Control
Injection
Energy saving pump with constant volume
or pressure a
djustment function.
Class
A
Esay Control Hydraulic Indoor Unit Controler
4 Heating mode
Hydraulic unit
Linear Control
Injection
Evaporator
Normal
refrigerant
circuit
High Efficiency Class A Pump
Heating cycle
Outdoor unit
Automatic mode
High
Temperature
It realizes the high condensing temperature
without overheating discharge gas temperature
by Linear Control Injection process during
compression. Therefore, the condensing
temperature rises up higher than normal circuit.
A higher hot water temperature is realized by
controlling the injection amount according to the
usage state.
Product technology for Hydraulic Indoor Unit
Comfort/Reduce mode switching automatically
according to time program
Reduce mode
Constant reduce temperature
Constant
Comfort mode
Constant comfort temperature
Time
Protection mode
Stand-by mode with anti-frost protection
18
19
FEATURES
Energy Saving
Comfort Control
A program adjusts the hot water temperature
automatically in advance based on the outdoor
temperature, so hot water temperature can be controlled
so that setting temperature is maintained constantly.
Programmable timer
Peak Cut Function*
• The setting of timer operation can easily be adjusted.
• Changing the heating mode linked with time is possible.
This function performs operation by
setting a peak current value and reducing
the power consumption.
Mode
The ratio of suppressing
the power consumption
1
2
3
4
100%
75%
50%
Almost 0%
Day-Weekly timer setting
• The day-weekly timer can be set up for up to 3 times per day.
• Allows separate settings for each day of the week.
Holiday timer setting
• The holiday timer can be set up for up to 8 periods
• If you are absent for a long time in the winter, freezing of room
can be prevented.
Safety Function
Automatic heating curve operation
Auto-changeover
Automatic heating curve control based on outdoor temp and setting
room temperature.
If the cooling operation function is set, the system can automatically
switch to cooling or heating, depending on the outdoor temperature
to provide all-season comfortable air conditioning.
Anti-legionella function
Anti-freeze function
2 Zone Individual Control*
The growth of Legionella in DHW tank is suppressed and safe and
clean hot water is supplied at all times.
Water circulation and compressor can be automatically performed
at low outdoor temperature. Freezing of circulated water can be prevented.
Radiator
60
Leaving water
temperature (˚C)
Automatic temperature control
with heating curve
50
Chosen heating curve zone
Even if hot water temperature is different in 2 heating systems, they
can be controlled simultaneously.
40
High
Heater
Over
50°C
possible
30
Floor heating
-20
-15
-10
-5
0
5
10
15
20
Outdoor temperature (°C)
Setting
temperature
55ºC ~ 75ºC
30 ~ 360 min
Radiator
2nd
Circuit Kit
Outdoor temperature
Low
ON
~40°C
Heating curve off-set: Adjust setting room temp.
OFF
Anti-freeze mode
DHW Tank 300 L
Floor heating
Time
This can be fine adjusted when too warm or too cold.
Leaving water
temperature (°C)
High
2 Stage Low Noise Mode*
+4.5°C
Setting
heating curve
-4.5°C
Low
Low
Outdoor temperature (°C)
Outdoor unit can be switched to
silent mode, depending on the
installation environment.
(Valid only for High Power)
-2dB
Rated noise value
Low
noise
mode
Stage 1
-4dB
System can continuously supply hot water by built in back up heater
or boiler, as emergency, even if an error is occurred.
Radiator
Backup heater operation
Maintaining the room temperature during defrost operation by boost
start operation
20
Maintenance
Boiler*
Backup heater
Backup heater can operates at low outdoor temperature so that
comfortable status can be maintained. The backup heater is
controlled intelligently just as a security backup for very cold days/
nights and only activated when really necessary.
Operation status display
Quick error handling service and maintenance are possible by this
function.
Error
Stage 2
High
Quick recovery from defrost operation
Error/Maintenance alarm
Emergency operation
• Error history saves 10 errors in memory
• Display telephone NO. of service company
Massage
Floor heating
Outdoor unit
Hydraulic unit
*When additional boiler connected
*: Optional parts are required.
21
PRODUCT LINEUP
for various needs
Type
High Power series
Comfort series
Usable outdoor
temperature:
High Power series
Usable outdoor
temperature:
-25°C
Comfort series
Usable outdoor
temperature:
-20°C
Usable outdoor
temperature:
-25°C
Compact series
Usable outdoor
temperature:
-20°C
-20°C
Hydraulic indoor unit
Outdoor unit
Capacity range:
11/14 kW
System
11/14/16 kW
5/6/8 kW
10 kW
11/14 kW
11/14/16 kW
5/6/8 kW
10 kW
5 kW
8/10 kW
• 60°C hot water supply even at -20°C coutdoor
temperature
• 55°C hot water supply even at -10°C outdoor
temperature
• 60°C hot water supply even at -20°C outdoor
temperature
• 55°C hot water supply even at -10°C
outdoor temperature
• 55°C hot water supply even at -20°C
outdoor temperature
• Different heating system can be used. Like floor
heating, radiators and others.*
• Different heating system can be used .Like floor
heating, radiators and others.*
• Different heating system can be used .Like
floor heating, radiators and others.*
• Different heating system can be used.Like
floor heating, radiators and others.*
• Heating and DHW in one system.
• Heating and DHW in one system.*
• Heating and DHW in one system.*
• Additional electric heater for backup provided.
• Additional electric heater for backup provided.
• Heating and DHW space saving in one
hydraulic indoor unit.
• Heating and DHW space saving in one
hydraulic indoor unit.
• Additional electric heater for backup
provided.
• Additional electric heater for backup
provided.
• Up to two independent control circuits.*
• Up to two independent control circuits.*
• Solar connection for hot water production.*
• Solar connection for hot water
production.*
• Up to two independent control circuits.*
• Up to two independent control circuits.*
• Solar connection for hot water production.*
• Solar connection for hot water production.*
• Cascade connection up to three systems.*
• Cascade connection up to three systems.*
• Cooling operation is possible.*
• Cooling operation is possible.*
• Cascade connection up to three systems.*
• Cooling operation is possible.*
• Additional base heater can be
connected to prevent from freezing.*
• Cooling operation is possible.
• Cascade connection up to three systems.*
• Cooling operation is possible.*
Check the validity of label at
www.ehpa.org/QL
Power source
1Ø 230 V/50 Hz
3Ø 400 V/50 Hz
1Ø 230 V/50 Hz
1Ø 230 V/50 Hz
3Ø 400 V/50 Hz
1Ø 230 V/50 Hz
1Ø 230 V/50 Hz
5 kW
6 kW
8 kW
Capacity range
10 kW
11 kW
14 kW
16 kW
*Optional parts are required.
22
23
PRODUCT LINEUP
Single Phase power supply
11 kW
Powerful Heating
14 kW
High Power models realize high leaving water temperature and high heating capacity even at low ambient temperature by newly developed “Linear
Control Injection Technology”. It is possible to provide high water temperature and warm rooms in cold regions.
Hydraulic indoor unit
WSYG140DG6
Outdoor unit
WOYG112LCTA
WOYG140LCTA
series
High Power models realizes high
High Leaving Water Temperature
3 Phase power supply
11 kW
14 kW
No
backup
heater*
High leaving water temperature 60°C kept down
to -20°C outdoor temperature without using backup heater.
16 kW
Leaving water
temperature (°C)
High Power
* If you want to raise the hot water supply temperature, backup heater can be used for
the auxiliary operation.
heating capacity and high efficiency
60
High Power model
30
-20
-15
-10
-5
0
5
Outdoor temperature (°C)
by newly developed “Linear Control
Injection Technology” and “Co-axial
Hydraulic indoor unit
Heat Exchanger”.
WSYK160DG9
These properties are the key for a
Extended Operation Range Down to -25°C
Improved operation range down to -25°C outdoor temperature
reliable heating operation throughout
Outdoor unit
the whole year- even in a strong winter.
WOYK112LCTA
WOYK140LCTA
WOYK160LCTA
*:Check the validity of label at www.ehpa.org/QL
4.30
4.25
*
4.22
4.18
4.10
High COP
Energy efficiency is improved by the linear Control Injection Technology
and the optimization of refrigerant cycle control. High Power model
realizes high performance and high efficiency by adopting twin sensors
and control technology corresponding to hot water heating.
Single Phase
11 kW
14 kW
3 Phase
11 kW 14 kW 16 kW
A7W35 condition
FEATURES
Comfort Control
• Automatic heating curve operation
• Auto-changeover
• Cooling operation
• Quick recovery from defrost operation
• Backup heater operation
Cascade connection
Optimization of refrigerant cycle operation
High Power model realizes high performance and
high efficiency by adopting twin sensors and control
technology corresponding to hot water heating.
Hydraulic indoor units
Safety Function
• Anti-legionella function
• Anti-freeze function
• Emergency operation
• Error/Maintenance alarm
24
Hydraulic indoor unit
Temperature
sensor
Pump
Energy Saving
• Programmable timer
Outdoor unit
Emitter system
Refrigerant
Outdoor
units
Hot water
Balancing vessel
(Required optional part)
Under floor heating
Pressure sensor
Co-axial Heat Exchanger
25
PRODUCT LINEUP
5 kW
6 kW
8 kW
Heated up Comfortably
Comfort models realize high efficient operation by compact design
suited for European environment. Hot water temperature can be
controlled finely by All DC control and comfortable space heating
and domestic hot water are provided.
Hydraulic indoor unit
WSYA050DG6
WSYA100DG6
Outdoor unit
WOYA060LFCA
WOYA080LFCA
Comfort
series
High Leaving Water Temperature
No
backup
heater*
Maximum leaving water temperature is 55°C
without backup heater. Hot water supply temperature can be
maintained even at –10°C outdoor temperature.
10 kW
Leaving water
temperature (°C)
* If you want to raise the hot water supply temperature, backup heater can be
used for the auxiliary operation.
For Comfort series, optimized flow
60
55
50
40
30
temperature control is realized by DC
-10
inverter technology.
Hydraulic indoor unit
WSYA100DG6
Outdoor unit
WOYA100LFTA
-5
0
Wide Operation Range
5
10
15
20
Outdoor temperature (°C)
Improved operation range down to -20°C
outdoor temperature
High COP
4.52
5 kW
4.27
4.08
6 kW
8 kW
4.02
10 kW
A7W35 condition
FEATURES
Comfort Control
• Automatic heating curve operation
• Auto-changeover
• Cooling operation
• Quick recovery from defrost operation
• Backup heater operation
Cascade connection (10 kw model)
DC Fan Motor
Outdoor unit technology
High performance, high efficiency
small DC fan motor mounted.
Hydraulic indoor units
DC Twin Rotary Compressor
Safety Function
• Anti-legionella function
• Anti-freeze function
• Emergency operation
• Error/Maintenance alarm
26
620 mm
Energy Saving
• Programmable timer
830 mm
Pump
Outdoor
units
Balancing vessel
(Required optional part)
High efficient DC twin rotary compressor
DC Inverter
Under floor heating
5 - 8 kW
10 kW
Smooth water temperature control
realized by DC inverter control.
27
PRODUCT LINEUP
Single Phase power supply
11 kW
High Performance
14 kW
High Power models realize high leaving water temperature and high heating capacity even at low ambient temperature by newly developed “Linear
Control Injection Technology”. It is possible to provide high water temperature and warm rooms in cold regions.
Hydraulic indoor unit
WGYG140DG6
Outdoor unit
WOYG112LCTA
WOYG140LCTA
High Power
High Leaving Water Temperature
series
significant space saving because of
the integrated DHW tank. Quick hot
High leaving water temperature 60°C kept down
to -20°C outdoor temperature without using backup heater.
3 Phase power supply
11 kW
14 kW
Leaving water
temperature (°C)
Split DHW integrated type realizes
No
backup
heater*
* If you want to raise the hot water supply temperature, backup heater can be used for
the auxiliary operation.
16 kW
60
High Power model
30
-20
-15
-10
-5
0
5
Outdoor temperature (°C)
water supply is possible due to built-in
Extended Operation Range Down to -25°C
high performance DHW tank. Heating
and domestic hot water supply can
Hydraulic indoor unit
be selected inside the intelligent
Improved operation range down to -25°C outdoor temperature
WGYK160DG9
controller. High Power models realize
4.30
4.25
4.22
4.18
very efficient large heating capacities
4.10
by newly developed “Linear Control
Outdoor unit
Injection Technology” and “Co-axial
WOYK112LCTA
WOYK140LCTA
WOYK160LCTA
heat Exchanger”.
High COP
Energy efficiency is improved by the linear Control Injection Technology
and the optimization of refrigerant cycle control. High Power model
realizes high performance and high efficiency by adopting twin sensors
and control technology corresponding to hot water heating.
Single Phase
11 kW
14 kW
3 Phase
11 kW 14 kW 16 kW
A7W35 condition
FEATURES
Energy Saving
• Programmable timer
Optimization of refrigerant cycle operation
Outdoor unit
Co-axial Heat
Exchanger
Temperature
sensor
For Split DHW Integrated type
Hydraulic indoor unit
Emitter system
Pump
Hot water
Hydraulic indoor unit
Stylish space saving solution with
1,840 mm
Comfort Control
• Automatic heating curve operation
• Auto-changeover
• Cooling operation
• Quick recovery from defrost operation
• Backup heater operation
Shower
Refrigerant
Hot water
Pressure sensor
Safety Function
• Anti-legionella function
• Anti-freeze function
• Emergency operation
• Error/Maintenance alarm
28
DHW Tank
Supplied water
High Power model realizes high performance and high efficiency by adopting twin
sensors and control technology corresponding to hot water heating.
Hydraulic unit
DHW Tank 190 L
698 mm
Built in High Performance
DHW Tank 190 L
• DHW Production with coil
heat exchanger to optimise
the DHW performance
• Quick temperature rise due
to a big exchanger surface
648 mm
29
PRODUCT LINEUP
5 kW
6 kW
Heated up Comfortably
8 kW
Comfort models realize high efficient operation by compact design
suited for European environment. Hot water temperature can be
controlled finely by All DC control and comfortable space heating
and domestic hot water are provided.
Hydraulic indoor unit
WGYA050DG6
WGYA100DG6
Outdoor unit
WOYA060LFCA
WOYA080LFCA
Comfort
High Leaving Water Temperature
Maximum leaving water temperature is 55°C
without backup heater. Hot water supply temperature can be
maintained even at –10°C outdoor temperature.
series
inverter technology.
Leaving water
temperature (°C)
* If you want to raise the hot water supply temperature, backup heater can be
used for the auxiliary operation.
For Comfort series, optimized flow
temperature control is realized by DC
No
backup
heater*
60
55
50
40
30
-10
10 kW
-5
0
5
10
15
20
Outdoor temperature (°C)
Wide Operation Range
Improved operation range down to -20°C
outdoor temperature
Hydraulic indoor unit
WGYA100DG6
High COP
4.52
4.27
4.08
6 kW
8 kW
4.02
Outdoor unit
WOYA100LFTA
5 kW
10 kW
A7W35 condition
FEATURES
Safety Function
• Anti-legionella function
• Anti-freeze function
• Emergency operation
• Error/Maintenance alarm
30
High performance, high efficiency
small DC fan motor mounted.
DC Twin Rotary Compressor
830 mm
Energy Saving
• Programmable timer
DC Fan Motor
Outdoor unit technology
620 mm
Comfort Control
• Automatic heating curve operation
• Auto-changeover
• Cooling operation
• Quick recovery from defrost operation
• Backup heater operation
High efficient DC twin rotary compressor
DC Inverter
5 - 8 kW
10 kW
Smooth water temperature control
realized by DC inverter control.
31
PRODUCT LINEUP
High Performance
5 kW
Hydraulic indoor unit
WSYP100DG6
WPYA050LG
Smart installation Hydraulic Indoor Unit
Leaving water
temperature (°C)
* If you want to raise the hot water supply temperature, backup
heater can be used for the auxiliary operation.
Compact
55
60
• The compact Indoor unit provides two electrical
back up heater, each with 3kW capacity
50
• 12 L expansion vessel included
40
• No waste of space. DHW Kit installation inside
the hydraulic indoor unit possible.
-20
8 kW
No
backup
heater*
High leaving water temperature of 55°C keeps to -20°C outdoor
temperature without additional heater.
Outdoor unit
-15
-10
-5
Hydraulic indoor unit
WSYP100DG6
Only hydraulic connecting work is to be
High COP 4.50 (8 kW model)
High COP is realized by using a DC twin rotary compressor,
inverter technology, and high efficient water heat exchanger.
done. Circulation pump, safety valve
and automatic vent valve are included.
Outdoor unit
Easy installation and maintenance is
WPYA080LG
WPYA100LG
feasible.
Outdoor unit technology
32
DC Fan Motor
DC Twin Rotary Compressor
DC Inverter
High performance, high efficiency
small DC fan motor mounted.
High efficient DC twin rotary
compressor
Smooth water temperature control
realized by DC inverter control.
Easy installation &
maintenance!
All-in-One Model
Weight
Heating circuit pump
Ambient air
Monobloc unit
Weight
49 kg
Hydraulic
unit
5 kW model
Heating emitter
Hot water
Evaporator
675 mm
Energy Saving
• Programmable timer
Safety Function
• Anti-legionella function
• Anti-freeze function
• Emergency operation
• Error/Maintenance alarm
• Heat metering included
Improved operation range down to -20°C outdoor temperature
Refrigerant pipe work is unnecessary.
Comfort Control
• Automatic heating curve operation
• Auto-changeover
• Cooling operation
• Quick recovery from defrost operation
• Backup heater operation
• New generation controller. Connection by
Modbus protocol possible.
Wide Operation Range
10 kW
Compact designed heat pump.
FEATURES
0
5
Outdoor temperature (°C)
Compact
Design
72 kg
8 kW model
High Efficient
Plate Heat Exchanger
Very compact size achieved by a thin
high-efficiency heat exchanger
882 mm
series
High Leaving
Water Temperature
Compressor
Plate heat exchanger
33
SYSTEM
CONFIGURATION
&
OPTIONAL PARTS
Control
System Configuration
Optional Parts
34
35
Control
User`s needs are supported by offering
a variety of controls,
such as individual control and remote
control options.
Solar connection
Individual Controller
Adaptor for external device
Wireless Remote Control
(option)
Wired Remote Control
(option)
Web server (option)
Internet
UTW-KW1XD
UTW-KW4XD
Room Thermostat
UTW-C55XA
or
Room Thermostat
UTW-C58XD
Smartphone control
RF Module
UTW-MRCXD
Modbus clip (option)
UTW-KMBXE
Remote Control
UTW-C74TXF*1
UTW-C74HXF*1
Remote control system
Home Automation system
Remote Control
UTW-C78XD
*1: 19 Languages included,no separate Estern European RC necessary
Hydraulic Indoor Unit
Controller
Simple operation mode setting
• Selecting the heating mode and Domestic
hot water operation
Large LCD display
• Operation status display
• Error display
• plain text
Navigation and setting
• Selecting the heating menu
• Setting program timer
36
Service & Maintenance Tool
LPB clip (option)
UTW-KL1XD
Web server (option)
UTW-KW1XD
UTW-KW4XD
or
Service Tool (option)
HMI Kit (option)
UTW-KHMXE
Corresponding to multi languages
UTW-KPSXD*2
Software
UTW-KPSXD*3
*2: UTW-KW1XD or UTW-KW4XD is required
for the connection.
*3: UTW-KL1XD is required for the connection.
37
SYSTEM CONFIGURATION
Split type
System Configuration
System Components
(Optional Parts)
Basic Unit
Controller
(Optional Parts)
System Case Studies
Heating
& Hot Water
(Locally purchased)
Hot Water
(Locally purchased)
2 emitter simultaneous heating (Individual control)
Hydraulic Indoor Unit
High Power series
WSYG140DG6
WSYK160DG9
Hot Water
Solar
(Locally purchased)
Boiler
(Locally purchased)
Hydraulic indoor units
Shower
Pump
DHW Tank
Comfort series
WSYA100DG6
Boiler Connection Kit
UTW-KBDXD
& Balancing Vessel
UTW-TEVXA
Valve
Pump
Radiator
Bath
UTW-T20XA
UTW-T30XA
UTW-T30XD
2nd Circuit Kit
UTW-KZDXD*
Cascade Kit
UTW-KCMXE
(for master)
UTW-KCSXE
(for slave)
Outdoor
units
Boiler connected to heating (Boiler + Heating)
Radiator
Hydraulic indoor units
Fan Coil
Heat Exchanger
UTW-ESPXA
& Swimming Pool Kit
UTW-KSPXD*
Boiler
Swimming Pool
Valve
Pump
Outdoor
units
Outdoor Unit
Wired
Remote Control
High Power series
WOYG112LCTA
WOYG140LCTA
Valve
Pump
Radiator
Floor Heating
Room Thermostat
UTW-C55XA
2 emitter simultaneous heating & Domestic Hot Water (Cascade)
Remote Control
UTW-C74TXF
WOYK112LCTA
WOYK140LCTA
WOYK160LCTA
Type
A
or
Hydraulic indoor
units
Tank
Hot water supply
(e.g. for shower)
Wireless
Remote Control
Valve
RF Module
UTW-MRCXD
Room Thermostat
UTW-C58XD
Comfort series
WOYA060LFCA
WOYA080LFCA
WOYA100LFTA
Pump
Valve
Outdoor
units
Web-Server
UTW-KW1XD
UTW-KW4XD
Radiator
Balancing vessel (Option)
Remote Control
UTW-C78XD
Type
B
Tank
Hydraulic indoor units
Internet
Locally purchased
Gas Refrigerant
Liquid Refrigerant
Flow pipe
Return pipe
Remote Controller
Cable
Domestic Hot
Water
Web server Cable
Hot water supply
(e.g. for shower)
Valve
*Regulation Extension Kit (UTW-KREXD) is required.
38
Pump
Pump
Valve
Outdoor
units
Pump
Radiator
Balancing vessel (Option)
39
SYSTEM CONFIGURATION
Split DHW Integrated type
System Case Studies
System Configuration
Basic Unit
Hydraulic Indoor Unit
System Components
(Optional Parts)
Controller
(Optional Parts)
Boiler (Locally purchased)
Heating
& Hot Water
(Locally purchased)
Hot Water
(Locally purchased)
Single heating & Domestic Hot Water
Hot Water
High Power series
WGYG140DG6
WGYK160DG9
Boiler Connection Kit
UTW-KBDXD
& Balancing Vessel
UTW-TEVXA
Shower
Comfort series
WGYA050DG6
WGYA100DG6
Hot water supply
(e.g. for shower)
Hydraulic indoor unit
Bath
Outdoor
unit
2nd Circuit Kit
UTW-KZDXD*
Radiator
Radiator
Heat Exchanger
UTW-ESPXA
& Swimming Pool Kit
UTW-KSPXD*
Fan Coil
Swimming Pool
Outdoor Unit
2 emiter simultaneous heating (Individual control)
& Domestic Hot Water
High Power series
WOYG112LCTA
WOYG140LCTA
Wired
Remote Control
WOYK112LCTA
WOYK140LCTA
WOYK160LCTA
Hot water supply
(e.g. for shower)
Floor Heating
Hydraulic indoor unit
Room Thermostat
UTW-C55XA
Outdoor
unit
Remote Control
UTW-C74TXF
Radiator
Floor heating
or
Comfort series
WOYA060LFCA
WOYA080LFCA
Wireless
Remote Control
RF Module
UTW-MRCXD
Room Thermostat
UTW-C58XD
WOYA100LFTA
Boiler connected to heating (Boiler + Heating)
& Domestic Hot Water
Web-Server
UTW-KW1XD
UTW-KW4XD
Remote Control
UTW-C78XD
Hydraulic indoor
unit
Hot water supply
(e.g. for shower)
Boiler
*Regulation Extension Kit (UTW-KREXD) is required.
Internet
Locally purchased
Gas Refrigerant
Liquid Refrigerant
Flow pipe
Return pipe
Remote Controller
Cable
Domestic Hot
Water
Web server Cable
Outdoor
unit
Radiator
Floor heating
40
41
SYSTEM CONFIGURATION
Monobloc type
System Configuration
Basic Unit
Hydraulic Indoor Unit
System Components
(Optional Parts)
Controller
(Optional Parts)
Boiler
(Locally purchased)
Heating & Hot Water
(Locally purchased)
Hot Water
(Locally purchased)
Single heating system
Hot Water
Solar
(Locally purchased)
WSYP100DG6
System Case Studies
DHW Tank
Shower
Hydraulic indoor unit
Bath
Outdoor
unit
UTW-T20XA
UTW-T30XA
UTW-T30XD
Floor heating
Radiator
Monobloc Unit
WPYA050LG
Fan Coil
Heat Exchanger
UTW-ESPXA
& Swimming Pool Kit
UTW-KSPXD*
Boiler connected to heating (Boiler + Heating)
or
Floor Heating
WPYA080LG
WPYA100LG
Wired
Remote Control
Hydraulic indoor unit
Boiler
Room Thermostat
UTW-C55XA
Swimming Pool
Valve
Remote Control
UTW-C74TXF
Outdoor
unit
or
Floor heating
Wireless
Remote Control
RF Module
UTW-MRCXD
Room Thermostat
UTW-C58XD
Web-Server
UTW-KW1XD
UTW-KW4XD
2 types of heat distribution
Remote Control
UTW-C78XD
Hot water Supply
(e.g. for shower)
Internet
Hydraulic indoor unit
Locally purchased
Note: 1. Only one heating circuit can be connected.
2. Only one Controller (Option) can be connected.
Modbus Clip
UTW-KMBXE
42
Home Automation
System
Locally purchased
Flow pipe
Return pipe
Remote Controller Cable
Web server Cable
Domestic Hot Water
Outdoor
unit
Tank
Floor heating
43
OPTIONAL PARTS
Optional parts compatibility for system
Optional parts compatibility for control
Split
Product Name
High Power
Model Name
1Ø
Split DHW integrated type
Comfort
3Ø
High Power
1Ø
1Ø
Comfort
Compact
1Ø
1Ø
3Ø
Split
Monobloc
11
14
11
14
16
5
6
8
10
11
14
11
14
16
5
6
8
10
5
8
10
UTW-KZSXE
●
●
●
●
●
●
●
●
●
—
—
—
—
—
—
—
—
—
—
—
—
UTW-KZDXE
—
—
—
—
—
—
—
—
—
●
●
●
●
●
●
●
●
●
—
—
—
High Power
Model Name
Product Name
HMI Kit
1Ø
Split DHW integrated type
Comfort
3Ø
High Power
1Ø
1Ø
Monobloc
Comfort
Compact
1Ø
1Ø
3Ø
11
14
11
14
16
5
6
8
10
11
14
11
14
16
5
6
8
10
5
8
10
UTW-KHMXE*3
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
UTW-C74TXF*3
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
UTW-C74HXF*3 ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
UTW-C78XD-E*4 ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
2nd
Circuit Kit
Wired
UTW-KBSXD
●
●
●
●
●
●
●
●
●
—
—
—
—
—
—
—
—
—
—
—
—
Remote
Controller
Boiler
Connection kit
UTW-KBDXD
—
—
—
—
—
—
—
—
—
●
●
●
●
●
●
●
●
●
—
—
—
UTW-C78XD
Wireless
Balancing vessel
UTW-TEVXA
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
UTW-KDWXG
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
●
●
●
(Internal)
Wired
UTW-C55XA
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Wireless
UTW-C58XD
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Room
Thermostat
DHW kit
UTW-KDWXD
●
●
●
●
●
●
●
●
● — *1 — *1 — *1 — *1 — *1 — *1 — *1 — *1 — *1 ●
●
●
200 Liter
300 Liter
UTW-T20XA
UTW-T30XA
●
●
●
●
●
●
●
●
● — *1 — *1 — *1 — *1 — *1 — *1 — *1 — *1 — *1 ●
●
●
Outdoor Sensor
Transmitter
UTW-MOSXD
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
300 Liter
UTW-T30XD
●
●
●
●
●
●
●
●
● — *1 — *1 — *1 — *1 — *1 — *1 — *1 — *1 — *1 ●
●
●
RF Modules
UTW-MRCXD
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Circulating pump
UTW-PHFXD
●
●
●
●
●
—
—
—
—
●
●
●
●
●
—
—
—
—
—
—
—
Web server
UTW-KW1XD
UTW-KW4XD
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Swimming
Pool kit
UTW-KSPXD
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
LPB Clip
UTW-KL1XD
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Heat Exchanger for
swimming pool kit
UTW-ESPXA
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Modbus Clip
UTW-KMBXE
— *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 — *7 ●
●
●
Cooling kit
UTW-KCLXD
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● — *2 — *2 — *2
Regulation
Extension Kit
UTW-KREXD
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Low Noise Kit
UTW-KLNXE
●
●
●
●
●
—
—
—
—
●
●
●
●
●
—
—
—
—
—
—
—
Service Tool
(incl.OCI700 adaptor)
UTW-KSTXD
●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5 ●*5
Drain Pan
UTW-KDPXA
—
—
—
—
—
●
●
●
—
—
—
—
—
—
—
—
—
—
—
—
—
Service Tool
Software
UTW-KPSXD
●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6 ●*6
Cascade Master Kit
(incl. LPB Clip)
UTW-KCMXE
●
●
●
●
●
—
—
—
●
—
—
—
—
—
—
—
—
—
—
—
—
External connect kit
UTY-XWZXZ2
Cascade Slave Kit
(incl. LPB Clip)
UTW-KCSXE
●
●
●
●
●
—
—
—
●
—
—
—
—
—
—
—
—
—
—
—
—
(External)
DHW tank
for BSB-Port
UTW-HAMXE
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
●
●
UTW-HAMXF
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
●
—
—
Base Heater
44
●
●
●
●
●
—
—
—
—
●
●
●
●
*1: DHW operation is possible without DHW Kit and DHW Tank.
*2: Cooling operation is possible without cooling kit
*3: 19 Languages included,no separate Estern European RC necessary
*4: Eastern European Language(English, Czech Republic, Slovakia, Poland, Turkey, Hungary, Russia, Slovenia, Greece, Serbia)
*5: U TW-KL1XD is required for the connection. C74TXF: Built in Room Temperature sensor C74HXF: Built in Room temperature and Humidity sensor
*6: UTW-KW1XD or UTW-KW4XD is required for the connection.
*7: Additional optional part necessary
●
—
—
—
•
—
: Available
—
—
—
— : Not Available
45
OTHERS
Simple Installation & Maintenance
Installation Information
Specifications & Dimensions
Model Selection Software
46
47
SIMPLE INSTALLATION & MAINTENANCE
Simplified installation
Easy Installation & Maintenance
Pre-setting configurations
Outdoor temperature simulation
When installed, the controller makes it simple to set system settings
without having to individually set the system’s components and units.
It can be checked whether each unit operates correctly under the set
conditions and expected outdoor temperatures when the system is
actually assembled.
• All hydraulic safety & controlling components built in, no additional selection required
Easy pre-setting 8 pattern systems
(Duo heating : 12 patterns)
Hot water shower
Tank
Outdoor
unit
Indoor unit
Outdoor
unit
Radiator
Valve Pump
• Refrigerant pump down operation
Pump
Valve
Pump
Pump
• Easy access for maintenance operations
• No installation of refrigerant circuit connections (Only Monobloc)
Hydraulic Indoor unit
Indoor unit
• Lifting bars for an installation without any difficulty or risk
Radiator
Under floor heating
Outdoor
unit
Under floor
heating
Valve
Under floor heating
Indoor unit
Outdoor temperatures in the range from –50°C to +50°C can be
simulated.
Outdoor
unit
Indoor unit
Valve
Outdoor
unit
Maintenance Support
Tank
Hot water shower
Pump
Diagnotics function for trouble shooting
Floor drying
Configurstion
(Parameter 5700)
Type of installation
Pre setting 1
1 heating circuit
Pre setting 2
2 heating circuit
Pre setting 3
1 heating circuit & boiler backup
Pre setting 4
2 heating circuit & boiler backup
Pre setting 5
1/2 heating circuit & buffer control
Pre setting 6
1/2 heating circuit & buffer control & boiler backup
Pre setting 7
cascade connection Master
Pre setting 8
cascade connection A
Pre setting 9
cascade connection B/C
When floor heating is installed, it can be used to dry the concrete
surrounding the hot water piping more quickly to shorten the
construction period.
Set temperature
max. 75°C
Error display
Operation status display
Operation status display
How toknow
which error has appeared
When an error is occuring
i
Error symbol appears
on the controller
Set period
~25 Days
“Info” button
press “Info”
button
Detailed information will be displayed
• Error code
• Error designation
• Clear text info (UART)
• DHW & solar control auto detection
• pool heating & cooling optional
Controller features a large LCD display and buttons to make setting functions easy
Main operation flow and setting contents for installers and end users
Large display
Display of all segments operation mode indicate
•Clock •Temperature •DHW •Massage •Service/maintenance •Timer menu
1
Flow Chart
Example Item
Install Setting
Pump speed setting,Configuration. Heating
curve setting, Heat pump shout off
Hydraulic indoor unit error
Installers
Navigation
Reset
Cooling
mode
End users
48
POWER
MODE
DHW
information
switching
When an error is occurring
When an error is occurring green and red LED flash along with error
cause
Simple setting
Operation
mode
Outdoor unit error
2
Option Setting
Cooling kit, DHW kit, Boiler kit, Swimming
pool kit
3
Convenient
Function
Automatic Heating curve setting, Floor
controlled driving,Outdoor temperature
adjiustment, Maintenance period srtting
4
workout
Setting
5
Confirmation
Operation conform
(Heating cooling, DHW, option,)
6
User Setting
Date and time, time program, Operation
temperatur setting
Outdoor temperature simulator
LED2(GEEN)
LED1(RED)
Confirm flashing times
ERROR
: ON
: Blinks rapidly
Confirm blink code for error code indication
Check the error code table
49
INSTALLATION INFORMATION
1840 mm
300 mm
mini
350 mm
mini
300 mm
350 mm
mini
1000 mm
300 mm
mini
1000 mm
120 mm
600 mm
1000 mm
120 mm
600 mm
Hydraulic indoor unit
Hydraulic indoor unit
Hydraulic indoor unit
Outdoor unit
• Hydraulic unit is to be hang on the wall
• Weight < 60kg (including water)
• Distances for maintenance should be respected
• Floor stand
• Weight: 152 kg (without water)
• Distances for maintenance should be respected.
• Hydraulic unit is to be hang on the wall
• Weight < 60kg (including water)
• Distances for maintenance should be respected
• Floor stand
• Weight < 71 kg (without water)
• Distances for maintenance should be kept
Electrical Wiring
S
Electrical Wiring
Remote control (option)
Outdoor sensor
or
Remote control (option)
Outdoor sensor
or
Room thermostat (option)
Room thermostat (option)
or
or
Remote control (option)
Remote control (option)
or
Interconnection between the outdoor
unit and the hydraulic unit Phase,
Neutral, Earth, Communication bus
cable
Hydraulic unit
or
Room thermostat (option)
DHW power supply
cable
Hydraulic unit
Power supply cable to the
electrical back-ups cable
Interconnection between the outdoor
unit and the hydraulic unit Phase,
Neutral, Earth, Communication bus
cable
Electric panel
Outdoor sensor
DHW power supply
cable
Power supply cable to the
electrical back-ups cable
Electric panel
Power supply cable
SD
Room thermostat (option)
Power supply cable
Remote control (option)
or
Room thermostat (option)
or
Remote control (option)
or
Room thermostat (option)
Interconnection between the
outdoor unit and the hydraulic
unit Phase, Neutral, Earth,
Communication bus cable
DHW power supply
cable
Power supply cable to the
electrical back-ups cable
Electric panel
Power supply cable
50
51
SPECIFICATIONS & DIMENSIONS
Split type
Specifications (High Power series)
Model Name
Specifications (Comfort series)
Hydraulic indoor unit
WSYG140DG6
WSYG140DG6
WSYK160DG9
WSYK160DG9
WSYK160DG9
Outdoor unit
WOYG112LCTA
WOYG140LCTA
WOYK112LCTA
WOYK140LCTA
WOYK160LCTA
Capacity range
Heating capacity
7°C/35°C floor heating *
Input power
1
kW
COP
Heating capacity
2°C/35°C floor heating *1
Input power
kW
COP
Heating capacity
-7°C/35°C floor heating*1
Input power
kW
COP
11
14
11
14
16
10.80
13.50
10.80
13.50
15.17
2.54
3.23
2.51
3.20
3.70
4.25
4.18
4.30
4.22
4.10
10.77
12.00
10.77
13.00
13.50
3.44
3.87
3.40
4.15
4.34
Model Name
Hydraulic indoor unit
WSYA050DG6
WSYA100DG6
WSYA100DG6
WSYA100DG6
Outdoor unit
WOYA060LFCA
WOYA060LFCA
WOYA080LFCA
WOYA100LFTA
Capacity range
Heating capacity
7°C/35°C floor heating *
Input power
1
kW
COP
Heating capacity
2°C/35°C floor heating *1
Input power
3.13
3.10
3.17
3.13
3.11
COP
10.38
11.54
10.38
12.20
13.50
Heating capacity
4.32
5.08
4.28
5.13
5.40
2.40
2.27
2.43
2.38
2.50
-7°C/35°C floor heating*1
Input power
kW
kW
COP
Space heating characteristics*2
5
6
8
10
4.50
6.00
7.50
10.00
0.996
1.41
1.84
2.49
4.52
4.27
4.08
4.02
4.50
4.95
5.65
7.70
1.39
1.53
1.78
2.47
3.24
3.24
3.17
3.12
4.10
4.60
5.70
7.40
1.47
1.74
2.23
2.97
2.79
2.64
2.56
2.49
Space heating characteristics*2
Temperature application
°C
Energy efficiency class
55
35
55
35
55
35
55
35
55
35
Temperature application
A+
A++
A+
A+
A+
A++
A+
A++
A+
A+
Energy efficiency class
°C
55
35
55
35
55
35
55
35
A+
A++
A+
A++
A+
A++
A+
A++
Rated heat output(Prated)
kW
9
11
11
13
9
11
11
13
13
14
Rated heat output(Prated)
kW
4
4
5
5
6
7
8
8
Seasonal space heating energy efficiency(ηS)
%
109
151
113
148
112
154
117
150
117
149
Seasonal space heating energy efficiency(ηS)
%
115
169
115
169
118
156
113
155
kWh
6842
6062
8041
6824
6669
5930
7803
6738
9062
7408
Annual energy consumption
kWh
3026
2160
3180
2505
3886
3375
5415
Annual energy consumption
Hydraulic indoor unit
Sound power level
dB(A)
Outdoor unit
46
46
68
69
46
69
46
68
70
46
68
Hydraulic indoor unit
Sound power level
71
Hydraulic unit Specification
Outdoor unit
46
dB(A)
46
65
60
65
63
46
65
69
68
69
Hydraulic unit Specification
Power source
1 Ø 230 V 50 Hz
Dimensions H×W×D
Weight (Net)
Water circulation
Min/Max
Buffer tank capacity
3 N 400 V 50 Hz
mm
800 × 450 × 457
kg
42
L/min
19.5/39.0
24.4/48.7
Expansion vessel capacity
Power source
1 Ø 230 V 50 Hz
Dimensions H×W×D
mm
Weight (Net)
19.5/39.0
L
24.4/48.7
27.4/54.8
800 × 450 × 457
kg
Water circulation
16
Buffer tank capacity
Min/Max
42
L/min
8.1/16.2
10.8/21.7
13.5/27.1
L
L
8
Expansion vessel capacity
L
8
Max
°C
60
Leaving water temperature range
Max
°C
55
Water pipe connection diameter
Flow/Return
mm
Water pipe connection diameter
Flow/Return
mm
Ø 25.4/Ø 25.4
Capacity
kW
Capacity
kW
6.0(3.0kW×2pcs.)
Max
A
Backup heater
Ø 25.4/Ø 25.4
6.0(3.0kW×2pcs.)
9.0(3.0kW×3pcs.)
1 Ø 230 V 50 Hz
3 N 400 V 50 Hz
Backup heater
Outdoor unit specification
18.1/36.1
16
Leaving water temperature range
Outdoor unit specification
Power source
Current
Max
Dimensions H × W × D
A
22.0
25.0
8.5
mm
Weight (Net)
9.5
Power source
10.5
kg
Dimensions H × W × D
92
99
Additional refrigerant charge amount
Liquid
Diameter
Min/Max
Length(Pre-charge)
Height difference
Operation range
2.50
50
5/20
17.5
830 × 900 × 330
41
42
60
1.40
1.80
R410A (2,088)
Refrigerant amount
kg
Additional refrigerant charge amount
1.10
g/m
Liquid
Diameter
Connection pipe
18.5
620 × 790 ×290
kg
Ø 15.88
m
12.5
Refrigerant (Global warming potential)
Ø 9.52
mm
Gas
Length
kg
g/m
11.0
mm
Weight (Net)
R410A (2,088)
Refrigerant amount
1 Ø 230 V 50 Hz
Current
1,290 × 900 ×330
Refrigerant (Global warming potential)
Connection pipe
4415
46
Gas
Length
Min/Max
m
15
Length(Pre-charge)
Max
m
15
Height difference
Heating
°C
-25 to 35
Operation range
mm
25
40
Ø 6.35
Ø 9.52
Ø 12.70
Ø 15.88
m
5/30
m
15
Max
m
20
Heating
°C
-20 to 35
*1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard.
Usage environment, such as operation of the heating equipment, room temperature, and controller
adjustments, may cause disparities between practically determined values and these values.
*2:All information of ErP can be available for downloaded from www.fujitsu-general.com/global/products/erp-ecodesign/index.html.
Dimensions (High Power series)
Dimensions (Comfort series)
Outdoor Unit
Outdoor Unit
Hydraulic Indoor Unit
Outdoor Unit
Outdoor Unit
Hydraulic Indoor Unit
WOYG112LCTA/WOYG140LCTA
WOYK112LCTA/WOYK140LCTA/WOYK160LCTA
WSYG140DG6/WSYK160DG9
WOYA060LFCA/WOYA080LFCA
WOYA100LFTA
WSYA050DG6/WSYA100DG6
650
650
450
330
12
Drain port Ø20
540
Top view
Heating flow
Ø25.4
20
479
Side view
21
21
Front view
52
Side view
Front view
Side view
31
330
12
457
97 98
790
62
290
20
Front view
77
Side view
Heating return
Ø25.4
830
Heating return
Ø25.4
900
81
620
1290
1290
97 98
Top view
Heating flow
Ø25.4
Front view
81
479
Side view
21
457
125
800
31
832,8
900
12
400
330
320
31
650
395
352
77
800
900
Top view
832,8
Top view
45.4
400
400
450
Front view
Side view
Front view
Side view
53
SPECIFICATIONS & DIMENSIONS
Split DHW Integrated type
Specifications (High Power series)
Model Name
Specifications (Comfort series)
Hydraulic indoor unit
WGYG140DG6
WGYG140DG6
WGYK160DG9
WGYK160DG9
WGYK160DG9
Outdoor unit
WOYG112LCTA
WOYG140LCTA
WOYK112LCTA
WOYK140LCTA
WOYK160LCTA
11
10.80
2.54
4.25
10.77
3.44
3.13
10.38
4.32
2.40
14
13.50
3.23
4.18
12.00
3.87
3.10
11.54
5.08
2.27
11
10.80
2.51
4.30
10.77
3.40
3.17
10.38
4.28
2.43
14
13.50
3.20
4.22
13.00
4.15
3.13
12.20
5.13
2.38
16
15.17
3.70
4.10
13.50
4.34
3.11
13.50
5.40
2.50
Capacity range
Heating capacity
Input power
COP
Heating capacity
Input power
COP
Heating capacity
Input power
COP
7°C/35°C floor heating *
1
2°C/35°C floor heating *1
-7°C/35°C floor heating*1
Space heating characteristics*2
Temperature application
Energy efficiency class
Rated heat output(Prated)
Seasonal space heating energy efficiency(ηS)
kW
kW
Hydraulic indoor unit
Annual energy consumption
Domestic hot water characteristics*2
Load profile
Energy efficiency class
Energy efficiency(ηwh)
Annual electricity consumption
Hydraulic indoor unit Specification
Power source
Dimensions H×W×D
Weight (Net)
Water circulation
DHW capacity
Hot water heater capacity
Expansion vessel capacity
Leaving water temperature range
Water pipe connection diameter
Hot water pipe connection diameter
Backup heater
Outdoor unit specification
Power source
Current
Dimensions H × W × D
Weight (Net)
Refrigerant (Global warming potential)
Refrigerant amount
Additional refrigerant charge amount
Capacity
kW
35
A++
11
55
A+
11
35
A++
13
55
A+
13
35
A+
14
Space heating characteristics*2
Temperature application
Energy efficiency class
Rated heat output(Prated)
%
109
151
113
148
112
154
117
150
117
149
Seasonal space heating energy efficiency(ηS)
kWh
6842
6062
8041
6824
6669
5930
7803
6738
9062
7408
Annual energy consumption
68
70
46
68
69
46
69
46
mm
kg
L/min
L
kW
L
°C
mm
mm
mm
19.5/39.0
24.4/28.7
6.0(3.0kW×2pcs.)
A
mm
kg
22.0
Diameter
Length
Length(Pre-charge)
Height difference
Operation range
25.0
8.5
1,290 × 900 ×330
27.4/54.8
3 N 400 V 50 Hz
9.5
92
10.5
99
R410A (2,088)
2.50
50
Ø 9.52
Ø 15.88
5/20
15
15
-25 to 35
m
m
m
°C
WGYA100DG6
WGYA100DG6
WOYA060LFCA
WOYA080LFCA
WOYA100LFTA
5
4.50
0.996
4.52
4.50
1.39
3.24
4.10
1.47
2.79
6
6.00
1.41
4.27
4.95
1.53
3.24
4.60
1.74
2.64
8
7.50
1.84
4.08
5.65
1.78
3.17
5.70
2.23
2.56
10
10.00
2.49
4.02
7.70
2.47
3.12
7.40
2.97
2.49
Hydraulic indoor unit
Outdoor unit
kW
kW
55
A+
4
35
A++
4
55
A+
5
35
A++
5
55
A+
6
Min/Max
Max
Flow/Return
Capacity
35
A++
7
55
A+
8
35
A++
8
%
115
169
115
169
118
156
113
155
kWh
3026
2160
3180
2505
3886
3375
5415
4415
60
65
63
65
69
68
46
dB (A)
46
65
46
46
69
L
A+
120
880
%
kWh
1 Ø 230 V 50 Hz
1,840× 648 × 698
152
mm
kg
L/min
L
kW
L
°C
mm
mm
mm
8.1/16.2
10.8/21.7
13.5/27.1
190
1.5
12
18.1/36.1
190
1.5
12
55
Ø 25.4/Ø 25.4
Ø 19.05
6.0(3.0kW×2pcs.)
1 Ø 230 V 50 Hz
Max
A
mm
kg
11.0
12.5
620 × 790 ×290
17.5
41
18.5
830 × 900 ×330
60
42
R410A (2,088)
kg
g/m
Diameter
Connection pipe
kW
kW
Domestic hot water characteristics*2
Load profile
Energy efficiency class
Energy efficiency(ηwh)
Annual electricity consumption
Hydraulic indoor unit Specification
Power source
Dimensions H×W×D
Weight (Net)
Water circulation
DHW capacity
Hot water heater capacity
Expansion vessel capacity
Leaving water temperature range
Water pipe connection diameter
Hot water pipe connection diameter
Backup heater
Outdoor unit specification
Power source
Current
Dimensions H × W × D
Weight (Net)
Refrigerant (Global warming potential)
Refrigerant amount
Additional refrigerant charge amount
9.0(3.0kW×3pcs.)
mm
Max
Heating
24.4/48.7
WGYA100DG6
WOYA060LFCA
°C
Annual energy consumption
71
3 N 400 V 50 Hz
1,840× 648 × 698
152
19.5/39.0
190
1.5
12
60
Ø 25.4/Ø 25.4
Ø 19.05
kg
g/m
Liquid
Gas
Min/Max
46
68
L
A
88
1166
1 Ø 230 V 50 Hz
Max
-7°C/35°C floor heating*1
55
A+
9
1 Ø 230 V 50 Hz
Max
Flow/Return
2°C/35°C floor heating *1
35
A+
13
%
kWh
Min/Max
7°C/35°C floor heating *
55
A+
11
46
WGYA050DG6
Outdoor unit
Heating capacity
Input power
COP
Heating capacity
Input power
COP
Heating capacity
Input power
COP
1
35
A++
11
dB (A)
Outdoor unit
Hydraulic indoor unit
Capacity range
55
A+
9
°C
Annual energy consumption
Connection pipe
kW
Model Name
Length
Length(Pre-charge)
Height difference
Operation range
Liquid
Gas
Min/Max
Max
Heating
1.10
1.40
1.80
40
Ø 9.52
25
Ø 6.35
mm
Ø 12.70
Ø 15.88
m
m
m
°C
5/30
15
20
-20 to 35
*1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard.
Usage environment, such as operation of the heating equipment, room temperature, and controller
adjustments, may cause disparities between practically determined values and these values.
*2:All information of ErP can be available for downloaded from www.fujitsu-general.com/global/products/erp-ecodesign/index.html.
Dimensions (High Power series)
Dimensions (Comfort series)
Outdoor Unit
Outdoor Unit
Hydraulic Indoor Unit
Outdoor Unit
Outdoor Unit
Hydraulic Indoor Unit
WOYG112LCTA/WOYG140LCTA
WOYK112LCTA/WOYK140LCTA/WOYK160LCTA
WGYG140DG6/WGYK160DG9
WOYA060LFCA/WOYA080LFCA
WOYA100LFTA
WGYG140DG6/WGYK160DG9
31
330
900
12
31
330
Drain port Ø20
12
1840
1850
540
Top view
790
125
Top view
900
62
698
Front view
Side view
Front view
Side view
330
12
21
620
54
Side view
31
290
20
21
21
Front view
77
830
20
1290
1290
400
77
43
650
395
352
900
Top view
320
Top view
648
43
45.4
400
400
648
644
630
599
576
1850
644
630
599
576
1840
650
650
103
698
Side view
Front view
Side view
Front view
Side view
Front view
103
Side view
55
SPECIFICATIONS & DIMENSIONS
Monobloc type
Specifications
Hydraulic indoor unit
Model Name
WSYP100DG6
Outdoor unit
WPYA050LG
WPYA080LG
5
8
10
5.00
8.00
10.00
1.19
1.78
2.30
4.20
4.50
4.35
3.65
4.35
4.90
1.07
1.23
1.44
3.40
3.55
3.40
3.55
7.10
8.00
1.38
2.93
3.32
2.57
2.42
2.41
Capacity range
Heating capacity
7°C/35°C floor heating *1
Input power
kW
COP
Heating capacity
2°C/35°C floor heating *
Input power
1
kW
COP
Heating capacity
-7°C/35°C floor heating*1
Input power
kW
COP
WPYA100LG
Space heating characteristics*2
Temperature application
°C
Energy efficiency class
55
35
55
35
55
35
A+
A++
A+
A++
A+
A++
Rated heat output(Prated)
kW
4
4
6
7
7
8
Seasonal space heating energy efficiency(ηS)
%
118
171
123
168
118
167
kWh
3055
1952
3828
3580
4491
dB (A)
62
61
Annual energy consumption
Sound power level
Outdoor unit
65
3700
68
Hydraulic unit Specification
Power source
1 Ø 230 V 50 Hz
Dimensions H×W×D
mm
803 × 450 × 457
Weight (Net)
kg
40
Buffer tank capacity
L
22
Expansion vessel capacity
Water pipe connection diameter
Backup heater
L
12
Flow/Return
mm
Ø 25.4/Ø 25.4
Capacity
kW
6.0(3.0kW×2pcs.)
Outdoor unit specification
Power source
1 Ø 230 V 50 Hz
Dimensions H × W × D
mm
675 × 825 × 300
kg
49
Max
A
10.9
Min/Max
L/min
5.0/20.0
Flow/Return
mm
Ø 19.05/Ø 19.05
Weight (Net)
Current
Water circulation
Water pipe connection diameter
882 × 850 × 330
72
15.2
17.5
10.0/30.0
Ø 25.4/Ø 25.4
Refrigerant
R410A (2,088)
Refrigerant amount
kg
Leaving water temperature range
Operation range
1.05
1.72
Max
°C
55
Heating
°C
-20 to 35
*1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard.
Usage environment, such as operation of the heating equipment, room temperature, and controller
adjustments, may cause disparities between practically determined values and these values.
*2:All information of ErP can be available for downloaded from www.fujitsu-general.com/global/products/erp-ecodesign/index.html.
Dimensions
Outdoor Unit
Outdoor Unit
Hydraulic indoor Unit
WPYA050LG
WPYA080LG/WPYA100LG
WSYP100DG6
450
14
26
75 70
50
155
50
540
845
803
155
Top view
Top view
825
330
327
357
38
57 43
356
327
300
15
30
405
73
16
850
300
97 98
Side view
56
Front view
Side view
882
480
Side view
84
173
387.8
441.8
675
Front view
457
479
Side view
Front view
Side view
57
MODEL
SELECTION
Model selection with
detailed technical information
• The software automatically selects the equipments just by
inputting some factors, like the region where the equipment is
installed, required capacity to heat up the space, and a heating
method.
SOFTWARE
• The transition in the equipment capacity at each outdoor temperature condition and/or when back up heater is under operation
can be easily created by this software.
Fujitsu General’s new software for the
WATERSTAGE automatically provides
a combination of WATERSTAGE equipments just by giving few parameters.
The software is featured with multiple
languages, and automatic update function.
The entire system configuration can be reviewed and modified once
the units are selected. And by seeing the images and the list of
equipments at the same time, it avoids mistake in the selection of
equipments.
• The visible images of the optional items enables the correct
configuration of the systems.
• All of the associated optional items are automatically chosen in a
case the application requires several devices of the WATERSTAGE
equipments.
The software automatically provides graphs of monthly running
cost, CO2 emission volume, cost comparison against other heating
sources, and other data to allow the users to see at a glance the
financial benefit of choosing WATERSTAGE equipments.
Estimate function
Creating project files for customers
The software automatically provides the cost estimate of the entire
WATERSTAGE system, not only the equipment itself but also the
optional items.
Various kinds of documents such as an equipment list, a system
diagram, a cost estimate table, and an equipment CAD data can
be printed out to paper or output into the files. This function also
comes with a feature which allows you to change the template
design of the documents.
Software updates
The database can be automatically updated through FTP by automatic update function.
58
59
Room Heating
Domestic Hot Water
Swimming Pool
Cooling
and much more ...
・Specifications and design are subject to change without notice for future improvement.
・For further details, please check with our authorized dealer.
・The products or equipment in this catalogue contain fluorinated greenhouse gases.
・“
” is a worldwide trademark of FUJITSU GENERAL LIMITED
and is a registered trademark in Japan and other countries or areas.
・Other company and product names mentioned herein may be registered trademarks,
trademarks or trade names of their respective owners.
ISO 9001
Certified number : 01 100 89394
ISO 14001
Certified number : 01 104 9245/01
Fujitsu General (Thailand) Co., Ltd.
ISO 9001
Certified number : 01 100 79269
ISO 14001
Certified number : CNBJ311153-UK
Fujitsu General (Shanghai) Co., Ltd.
・Actual product's colors may be different from the colors shown in this printed material.
Distributed by :
3-3-17, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan
http://www.fujitsu-general.com/
Copyright© 2009-2014 Fujitsu General Limited. All rights reserved.
7EF017-1605E
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project