Elios4you - Installation Guide

Elios4you - Installation Guide
ATTENTION
ATTENTION: before installing Elios4you, remove
the label (see picture below) with USER code.
Keep the label in a safe place for future other
device configuration and/or for logging in the
website www.4-cloud.org.
ID CODE: 00000
Register on:
www.4-cloud.org
and associate your device with
USER: XXXXXXXX
ATTENZIONE: if you are setting a connection
through a Router/AP, data will be visible on
the website after approximately 1 hour from
configuration.
ELIOS4YOU
1. After device installation and after having it powered on, download the free App Elios4you on your own device (smartphone or
tablet) from Playstore (Android) or App Store (iOS)
2. Open the App and start the wizard, following the steps visible on your smartphone/tablet (read the Elios4you APP Quick Guide
for further information)
Guide
4. Check that collected data are correct:
- Press
“Home” button to to go the “Energy performance” page
- Check that energy “Generation” value
has similar value as you can read from the inverter
- Check that the energy “Consumption” value
is the same of the real time consumption you have in the home
Elios4you: a wireless device for the monitoring of single-phase photovoltic installations via
App. Maximum monitored power 6 kW. It measures the energy generated of the pv plant,
exchanged with the grid, the household consumption and the self-consumption.
ATTENTION: when Elios4you is configured for internet access through Router/AP, all data are collected even on 4-cloud website.
Go to http://www.4-cloud.org and follow on line instructions for registering. Match your account with the device filling with the USER
code on the label of your Elios4you.
TROUBLE SHOOTING
Installation - Power reading
Problem
Elios4you
Solutions
1. I can’t see my PV system energy
generation in the App’s home Page
a. Change current clamp (CT) versus (white label) by inverting the green dot or the inside current clamp arrow position.
b. Check that inside the current clamp you have only the PV Line cable (not also the Neutral).
c. Check that the current clamp core is not broken or cracked inside.
2. The energy generation visible on the App
is definitely less than the value read from
the inverter
a. Be sure that the Elios4you is powered from the same line of the 2 current clamps.
b. Check that the current clamp (white label) is perfectly closed: any strong pressure should be need to clamp the cable properly
3. Consumption graph has the same shape
of production graph line
a. Be sure that the mains CT (yellow label) clamps all lines coming from the Mains Meter: if not it is possible that the meter is measuring only
the consumption.
b. Be sure that the Neutral cable is not clamped within the CT (yellow and white label).
c. Check that both current clamps are not broken or cracked inside.
4. It seems that consumption values are
shown in the “grid” icon
a. Be sure that the mains CT (yellow label) clamps all lines coming from the Mains Meter: if not it is possible that the meter is measuring only
the consumption.
5. I can never see purchased energy in my
system
a. Be sure that the mains CT (yellow label) clamps all lines coming from the Mains Meter: if not it is possible that the meter is measuring only
the consumption.
6. During the night the consumption is zero,
while during the day is always more than
normal value expected
a. Reverse CT (yellow label) current clamp position, by inverting green dot/inside arrow position.
7. In the App I can see high consumption
levels, while the real time consumption
is very low.
a. Reverse CT (yellow label) current clamp position, by inverting green dot/inside arrow position.
b. Be sure that the mains CT (yellow label) clamps all lines coming from the Mains Meter: if not it is possible that the meter is measuring only
the consumption.
ID CODE:YYYYY
123456789XXXXX
Via Per Sacile, 158 - Francenigo di Gaiarine (TV) - Italy
Tel. (+39) 0434 768462 - Fax (+39) 0438 694617 - info@4-noks.com - www.4-noks.com
ENG
Quick
3. Set correct parameters for your PV system and your energy provider using the App menu:
- Press
“Menu” button
- Select
“Parameter Settings”
- Select “Energy Management” and set values
- Press OK when finished to save new values
ID Code Label
Current Transformers
+05T408021R1.1_E4U Quick Guide_EN_20.10.2014
!
INSTALLATION
INSTALLATION SCHEME
PHOTOVOLTAIC PLANT INTO THE MAIN CIRCUIT BREAKER
Generation
meter
N
N
Mains
meter
L
L
K
L
L
Green point and the direction
of the arrow K
L towards
the main circuit braker
Mains CT
(yellow label)
N
L
K
N
L
K
L
L
Green point and the direction
of the arrow K
L towards
the main circuit braker
Mains CT
(yellow label)
Generation CT
(white label)
Main
Circuit
Breaker
Do not wire
L
Do not wire
Do not wire
Alarm 1 -NO
Alarm 1 -NO
Load
13 14 15 16 17 18 19 20 21 22 23 24
Relay
Normally
Open
13 14 15 16 17 18 19 20 21 22 23 24
GND
Ctrl
+10 V
1A
GND
Ctrl
+10 V
Hole for
CONFIG button
Hole for
CONFIG button
ID Code Label
ID CODE:YYYYY
123456789XXXXX
SIG + Generation CT - Red color
Shield = optional Generation CT
SIG - Generation CT - Black color
ID Code Label
SIG - Mains CT - Black color
Shield = optional Mains CT
SIG + Mains CT - Red color
ID CODE:YYYYY
123456789XXXXX
SIG + Generation CT - Red color
Shield = optional Generation CT
SIG - Generation CT - Black color
Do not wire
Do not wire
!
Elios4you Front panel icons
Blink frequency proportional to the
amount of generated energy of the
pv plant
(red)
Power supply
(green)
Blink frequency proportional to the
amount of exchanged energy with
the grid
(red)
Wi-Fi on
(green)
If on: energy purchased from the
grid
(red)
General alarm or failed attempt
to get connected to the tablet or
smartphone
(green)
SIG - Mains CT - Black color
Shield = optional Mains CT
SIG + Mains CT - Red color
N L 3 4 5 6 7 8 9 10 11 12
N L 3 4 5 6 7 8 9 10 11 12
If on: energy sold to the grid
N
Alarm 2 -NO
Common Relay
Load
Relay
Normally
Open
Generation CT
(white label)
N
Alarm 2 -NO
Common Relay
K
Main
Circuit
Breaker
L
Do not wire
Generation
meter
The two L phases are
clamped into the mains CT
1A
Mains
meter
PHOTOVOLTAIC PLANT DIRECTLY WIRED INTO THE MAINS METER
Not used
(red)
(green)
WARNING
WARNING: if the generation energy LED
does
not blink when the pv instalaltion is producing
energy, it is necessary to invert the Generation CT
orientation by inverting the connection of the wires
of Elios4you (terminals 7 and 9).
WARNING: if the exchanged LEDs
and
detect the wrong energy flow (“sold” energy when
it should report a situation of “purchased” energy or
viceversa), it is necessary to invert the mains CT
(yellow label) by inverting the connection of the
wires of Elios4you (terminals 10 and 12).
!
WARNING
WARNING: make sure that between the 2 CTs
and the meters there are any other electrical
appliances connected. Otherwise, the resulting
measurements would not be reliable.
WARNING: possible alterations of CTs wires lenght
will cause an increase in the marginal error during
the measurements detection. We do not
recommend such alterations of the device.
ATTENTION
ATTENTION: installation must be done by
qualified personnel only.