HT9014 - HT Italia
HT9014
Rel. 1.02 of 12/07/10
AC TRMS professional clamp meter up to 600A
Pag 1 of 3
1. ELECTRICAL SPECIFICATIONS Accuracy is calculated as [% rdg + number of dgt) x resolution]. It is referred to 18°C ÷ 28°C with 75%RH
DC Voltage (Autorange)
Range
600.0mV
6.000V
60.00V
600.0V
1000V
Resolution
0.01mV
0.001V
0.01V
0.1V
1V
Accuracy
Input impedance
Overload protection
±(1.0%rdg + 3dgt)
10MΩ
1000VDC/ACrms
AC Voltage TRMS (Autorange)
Range
Resolution
Accuracy
Input
impedance
Bandwith
Overload protection
6.000V
60.00V
600.0V
1000V
0.001V
0.01V
0.1V
1V
±(1.0%rdg + 10dgt)
(50 ÷ 60Hz)
±(3.5%rdg + 5dgt)
(61 ÷ 400Hz)
10MΩ
50 ÷ 400Hz
1000VDC/ACrms
Integrated sensor for AC voltage detection: LED turn on for phase-earth voltage > 100V, 50/60Hz
Resistance and Continuity test (Autorange)
Range
600.0Ω
6.000kΩ
60.00kΩ
600.0kΩ
6.000MΩ
60.00MΩ
Resolution
0.1Ω
0.001kΩ
0.01kΩ
0.1kΩ
0.001MΩ
0.01MΩ
Accuracy
Buzzer
Overload protection
≤ 60Ω
600VDC/ACrms
Bandwith
Overload protection
±(1.0%rdg + 5dgt)
±(2.0%rdg + 10dgt)
Test current of continuity test: < 0.35mA
AC TRMS Current
Range
60.00A
600.0A
60.00A
600.0A
Resolution
0.01A
0.1A
0.01A
0.1A
Accuracy
±(2.8%rdg + 12dgt)
±(2.8%rdg + 8dgt)
±(4.5%rdg + 10dgt)
±(5.0%rdg + 10dgt)
50 ÷ 60Hz
600Arms
61 ÷ 400Hz
PEAK features: response time <10ms
Capacitance (Autorange)
Range
40.00nF
400.0nF
4.000µF
40.00µF
400.0µF
4000µF
Resolution
0.01nF
0.1nF
0.001µF
0.01µF
0.1µF
1µF
HT ITALIA SRL
Via della Boaria 40 - 48018 Faenza (RA)- Italy
Accuracy
±(3.5%rdg + 40dgt)
Overload protection
±(2.5%rdg + 5dgt)
600VACrms
±(5.0%rdg + 5dgt)
Tel: +39-0546-621002 - Fax: +39-0546-621144
email: export@htitalia.it - web: http://www.htitalia.com
HT9014
Rel. 1.02 of 12/07/10
AC TRMS professional clamp meter up to 600A
Pag 2 of 3
Diode test
Feature
Test current
0.9mA typical
Open voltage
2.8VDC
Frequency with test leads (Autorange)
Range
99.99Hz
999.9Hz
9.999kHz
60.00kHz
Resolution
0.01Hz
0.1Hz
0.001kHz
0.01kHz
Accuracy
Sensitivity
Overload protection
±(1.0%rdg + 5dgt)
> 15Vrms
600VDC/ACrms
Frequency with jaws (Autorange)
Range
99.99Hz
999.9Hz
9.999kHz
Resolution
0.01Hz
0.1Hz
0.001kHz
Accuracy
Sensitivity
Overload protection
±(1.0%rdg + 5dgt)
>10Arms (60A)
>50Arms (600A)
600AACrms
Resolution
0.1%
Sensitivity
> 15Vrms
Accuracy
±(1.2%rdg + 2dgt)
Duty Cycle (Autorange)
Range
0.5% ÷ 99.0%
Temperature with type K probe (Autorange)
Range
-20.0÷400.0°C
400 ÷ 760°C
-4.0 ÷ 752.0°F
752 ÷ 1400°F
Resolution
0.1°C
1°C
0.1°F
1°F
Accuracy (*)
±(2.0%rdg + 3°C)
±(2.0%rdg + 5°C)
±(2.0%rdg + 6°F)
±(2.0%rdg + 9°F)
Overload protection
600VDC/ACrms
(*) Accuracy of type K probe not considered
HT ITALIA SRL
Via della Boaria 40 - 48018 Faenza (RA)- Italy
Tel: +39-0546-621002 - Fax: +39-0546-621144
email: export@htitalia.it - web: http://www.htitalia.com
HT9014
Rel. 1.02 of 12/07/10
AC TRMS professional clamp meter up to 600A
Pag 3 of 3
2. GENERAL SPECIFICATIONS Mechanical characteristics
Size:
Weight (including battery):
Max conductor size:
215(L) x 74(La) x 43(H)mm
285g
30mm
Supply
Battery type:
Low battery indication:
Battery life:
AutoPowerOff:
1 battery 9V NEDA 1604 IEC 6F22 JIS 006P.
“
” is displayed when the battery level is too low.
about 200 hours
about 15 minutes of idleness
Display
Characteristics:
Sample rate:
Conversion mode:
4 LCD (max 6000 counts), decimal point, unit symbol indication,
bargraph and backlight
2 times/sec
TRMS
Climatic conditions
Reference temperature:
Operating temperature:
Operating humidity:
Storage temperature:
Storage humidity:
18°C ÷ 28°C
5 ÷ 40 °C
<80%RH
-20 ÷ 60 °C
<80%RH
Reference standards
Comply with:
Insulation:
Pollution:
For inside use, max height:
Installation category:
IEC/EN 61010-1
double insulation
Level 2
2000m
CAT IV 600V, CAT III 1000V to ground
This product conforms to the prescriptions of the European directive on low voltage 2006/95/EEC
and to EMC directive 2004/108/EEC
HT ITALIA SRL
Via della Boaria 40 - 48018 Faenza (RA)- Italy
Tel: +39-0546-621002 - Fax: +39-0546-621144
email: export@htitalia.it - web: http://www.htitalia.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising