HT9014 Rel. 1.02 of 12/07/10 AC TRMS professional clamp meter up to 600A Pag 1 of 3 1. ELECTRICAL SPECIFICATIONS Accuracy is calculated as [% rdg + number of dgt) x resolution]. It is referred to 18°C ÷ 28°C with 75%RH DC Voltage (Autorange) Range 600.0mV 6.000V 60.00V 600.0V 1000V Resolution 0.01mV 0.001V 0.01V 0.1V 1V Accuracy Input impedance Overload protection ±(1.0%rdg + 3dgt) 10MΩ 1000VDC/ACrms AC Voltage TRMS (Autorange) Range Resolution Accuracy Input impedance Bandwith Overload protection 6.000V 60.00V 600.0V 1000V 0.001V 0.01V 0.1V 1V ±(1.0%rdg + 10dgt) (50 ÷ 60Hz) ±(3.5%rdg + 5dgt) (61 ÷ 400Hz) 10MΩ 50 ÷ 400Hz 1000VDC/ACrms Integrated sensor for AC voltage detection: LED turn on for phase-earth voltage > 100V, 50/60Hz Resistance and Continuity test (Autorange) Range 600.0Ω 6.000kΩ 60.00kΩ 600.0kΩ 6.000MΩ 60.00MΩ Resolution 0.1Ω 0.001kΩ 0.01kΩ 0.1kΩ 0.001MΩ 0.01MΩ Accuracy Buzzer Overload protection ≤ 60Ω 600VDC/ACrms Bandwith Overload protection ±(1.0%rdg + 5dgt) ±(2.0%rdg + 10dgt) Test current of continuity test: < 0.35mA AC TRMS Current Range 60.00A 600.0A 60.00A 600.0A Resolution 0.01A 0.1A 0.01A 0.1A Accuracy ±(2.8%rdg + 12dgt) ±(2.8%rdg + 8dgt) ±(4.5%rdg + 10dgt) ±(5.0%rdg + 10dgt) 50 ÷ 60Hz 600Arms 61 ÷ 400Hz PEAK features: response time <10ms Capacitance (Autorange) Range 40.00nF 400.0nF 4.000µF 40.00µF 400.0µF 4000µF Resolution 0.01nF 0.1nF 0.001µF 0.01µF 0.1µF 1µF HT ITALIA SRL Via della Boaria 40 - 48018 Faenza (RA)- Italy Accuracy ±(3.5%rdg + 40dgt) Overload protection ±(2.5%rdg + 5dgt) 600VACrms ±(5.0%rdg + 5dgt) Tel: +39-0546-621002 - Fax: +39-0546-621144 email: export@htitalia.it - web: http://www.htitalia.com HT9014 Rel. 1.02 of 12/07/10 AC TRMS professional clamp meter up to 600A Pag 2 of 3 Diode test Feature Test current 0.9mA typical Open voltage 2.8VDC Frequency with test leads (Autorange) Range 99.99Hz 999.9Hz 9.999kHz 60.00kHz Resolution 0.01Hz 0.1Hz 0.001kHz 0.01kHz Accuracy Sensitivity Overload protection ±(1.0%rdg + 5dgt) > 15Vrms 600VDC/ACrms Frequency with jaws (Autorange) Range 99.99Hz 999.9Hz 9.999kHz Resolution 0.01Hz 0.1Hz 0.001kHz Accuracy Sensitivity Overload protection ±(1.0%rdg + 5dgt) >10Arms (60A) >50Arms (600A) 600AACrms Resolution 0.1% Sensitivity > 15Vrms Accuracy ±(1.2%rdg + 2dgt) Duty Cycle (Autorange) Range 0.5% ÷ 99.0% Temperature with type K probe (Autorange) Range -20.0÷400.0°C 400 ÷ 760°C -4.0 ÷ 752.0°F 752 ÷ 1400°F Resolution 0.1°C 1°C 0.1°F 1°F Accuracy (*) ±(2.0%rdg + 3°C) ±(2.0%rdg + 5°C) ±(2.0%rdg + 6°F) ±(2.0%rdg + 9°F) Overload protection 600VDC/ACrms (*) Accuracy of type K probe not considered HT ITALIA SRL Via della Boaria 40 - 48018 Faenza (RA)- Italy Tel: +39-0546-621002 - Fax: +39-0546-621144 email: export@htitalia.it - web: http://www.htitalia.com HT9014 Rel. 1.02 of 12/07/10 AC TRMS professional clamp meter up to 600A Pag 3 of 3 2. GENERAL SPECIFICATIONS Mechanical characteristics Size: Weight (including battery): Max conductor size: 215(L) x 74(La) x 43(H)mm 285g 30mm Supply Battery type: Low battery indication: Battery life: AutoPowerOff: 1 battery 9V NEDA 1604 IEC 6F22 JIS 006P. “ ” is displayed when the battery level is too low. about 200 hours about 15 minutes of idleness Display Characteristics: Sample rate: Conversion mode: 4 LCD (max 6000 counts), decimal point, unit symbol indication, bargraph and backlight 2 times/sec TRMS Climatic conditions Reference temperature: Operating temperature: Operating humidity: Storage temperature: Storage humidity: 18°C ÷ 28°C 5 ÷ 40 °C <80%RH -20 ÷ 60 °C <80%RH Reference standards Comply with: Insulation: Pollution: For inside use, max height: Installation category: IEC/EN 61010-1 double insulation Level 2 2000m CAT IV 600V, CAT III 1000V to ground This product conforms to the prescriptions of the European directive on low voltage 2006/95/EEC and to EMC directive 2004/108/EEC HT ITALIA SRL Via della Boaria 40 - 48018 Faenza (RA)- Italy Tel: +39-0546-621002 - Fax: +39-0546-621144 email: export@htitalia.it - web: http://www.htitalia.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising