Single-Gas Detector Long-term solution

Single-Gas Detector Long-term solution
Single-Gas Detector
H2S, CO, O2, SO2, NH3, PH3, Cl2, ClO2, NO, NO2, HCN, ETO, O3
Long-term solution
Compact and affordable, the GasAlert Extreme reliably monitors for any
single gas hazard within its wide range of available toxic gas models. With
easy on/off operation, this single gas detector offers extended longevity
with a field-replaceable battery and sensor. A wide range of tamperproof
user options and multi-language display make the GasAlert Extreme an
ideal solution for a variety of applications; plus, datalogging is standard
on all units. Calibration is a simple automatic procedure and is compatible
with BW’s MicroDock II automatic test and calibration system.
Standard Package Contents
• Detector complete with specified sensor, stainless steel alligator clip
and concussion-proof housing
• Calibration/test cap and hose
•Manual
• Multi-language CD manual
General Specifications
Size
1.1 x 2.0 x 3.75 in. / 2.8 x 5.0 x 9.5 cm
Weight
2.9 oz. / 82 g
Typical battery life
1.5 year battery life (typical) with
replaceable 3V battery
Certifications and
approvals
h
Warranty
Class I, Div. 1, Gr. A, B, C, D
Class II, Div. 1, Gr. E, F, G
American Bureau of Shipping
ATEX:
X g II 1 G
Ex ia IIC T4
IECEx:
Ex ia IIC T4
X:
European Conformity
Full two year warranty including sensors
(One year Cl2, NH3, O3, ETO and ClO2 sensors)
5558-12
4
5062-26-NCL-EN
Single-Gas Detector
Order Number*
GasAlert Extreme
Measuring Range
Ammonia (NH3)
0-100 ppm
GAXT-A-DL
Yellow
GAXT-A-DL-B
Black
Ammonia (NH3) (extended range)
0-400 ppm
GAXT-A2-DL
GAXT-A2-DL-B
Carbon monoxide (CO)
0-1000 ppm
GAXT-M-DL
GAXT-M-DL-B
Carbon monoxide (CO-H), H2 resistant
0-1000 ppm
GAXT-M2-DL
GAXT-M2-DL-B
Chlorine (Cl2)
0-50.0 ppm
GAXT-C-DL
GAXT-C-DL-B
Chlorine dioxide (ClO2)
0-1 ppm
GAXT-V-DL
GAXT-V-DL-B
Ethylene oxide (ETO) (C2H4O)
0-100 ppm
GAXT-E-DL
GAXT-E-DL-B
Hydrogen cyanide (HCN)
0-30.0 ppm
GAXT-Z-DL
GAXT-Z-DL-B
Hydrogen sulfide (H2S)
0-100 ppm
GAXT-H-DL
GAXT-H-DL-B
Hydrogen sulfide (H2S) (extended range)
0-500 ppm
GAXT-H-2-DL
GAXT-H-2-DL-B
Nitric oxide (NO)
0-250 ppm
GAXT-N-DL
GAXT-N-DL-B
Nitrogen dioxide (NO2)
0-99.9 ppm
GAXT-D-DL
GAXT-D-DL-B
Oxygen (O2)
0-30.0%
GAXT-X-DL-2
GAXT-X-DL-B-2
Ozone (O3)
0-1 ppm
GAXT-G-DL
GAXT-G-DL-B
Phosphine (PH3)
0-5.0 ppm
GAXT-P-DL
GAXT-P-DL-B
Sulfur dioxide (SO2)
0-100 ppm
GAXT-S-DL
GAXT-S-DL-B
*Add “-BR” to the end of the order number for INMETRO certified detectors (for Brazil only).
Gas Legend
Cl2
ClO2
Chlorine (C)
NO
Nitric oxide (N)
Chlorine dioxide (V)
NO2
Nitrogen dioxide (D)
CO
Carbon monoxide (M)
O2
Oxygen (X)
ETO
Ethylene oxide
(C2H4O) (E)
O3
Ozone (G)
H2S
Hydrogen sulfide (H)
PH3
Phosphine (P)
HCN
Hydrogen cyanide (Z)
SO2
Sulfur dioxide (S)
NH3
Ammonia (A)
MicroDock II
Automatic test and calibration
station (see MicroDock II section
for additional information)
5062-26-NCL-EN
IR DataLink
GA-USB2
USB adaptor
5
GasAlert Extreme (continued)
Carrying & Protective Accessories
Order Number
Concussion-proof boot with stainless steel alligator-style clip
GA-BALERT
Splash guard filters for use with concussion-proof boot (GA24-BALERT) (kit of 5)
GA-BSPLASH-K
Hard hat clip (non-conductive)
GA-HC-1
Belt clip with screw
GA-CL-1
Neck strap with safety release
GA-NS-1
Short strap (6 in. / 15.2 cm)
GA-LY-1
Extension strap (4 ft. / 1.2 m)
GA-ES-1
Chest harness
GA-CH-2
Sampling & Testing Equipment
Order Number
SamplerPak motorized sampling pack kit
GA-SPAK
Deluxe SamplerPak motorized sampling pump kit with alkaline batteries, rechargeable batteries and
battery charger
GA-SPAK-NA
Hard-sided carrying case for motorized sampling pump and/or the detector
SPAK-CC1
Manual aspirator pump kit with probe (1 ft. / 0.3 m)
GA-AS02
Test cap and hose (1 ft. / 0.3 m) replacement (included with detector)
GA-TC-1
Note: For complete list of Sampling & Testing Equipment, see the Sampling Equipment section.
Power Replacements
Order Number
Battery - lithium, 3V
E2829
Datalogging Accessories
Order Number
IR DataLink USB adaptor
GA-USB2
Concussion-Proof Boot
GA-BALERT
Short Strap
GA-LY-1
Neck strap
GA-NS-1
Test Cap Replacement
GA-TC-1
Splash Guard Filters
GA-BSPLASH-K
For concussion-proof boot
6
5062-26-NCL-EN
GasAlert Extreme (continued)
MicroDock II
Order Number
MicroDock II Automated Calibration and Testing Station (not compatible with ClO2 or O3):
- Base station plus GasAlert Extreme docking module
- GasAlert Extreme docking module
DOCK2-2-1D-00-G
DOCK2-0-1D-00-G
For complete MicroDock II system configuration information, see MicroDock II section.
Replacement Sensor Screens
Order Number
Replacement sensor screens with gasket (kit of 10)
GAXT-SS
Replacement Sensors
Order Number
Replacement ammonia (NH3) sensor*
SR-A04
Replacement ammonia (NH3) sensor, extended range*
SR-A204
Replacement carbon monoxide (CO) sensor
SR-M04-SC
Replacement carbon monoxide (CO-H) sensor, H2 resistant
PS-RM04H
Replacement chlorine (Cl2) sensor*
PS-RC10
Replacement chlorine dioxide (ClO2) sensor*
SR-V04
Replacement ethylene oxide (ETO) sensor*
SR-E04
Replacement hydrogen cyanide (HCN) sensor
PS-RZ10
Replacement hydrogen sulfide (H2S) sensor
PS-RH04S
Replacement nitric oxide (NO) sensor
SR-N04
Replacement nitrogen dioxide (NO2) sensor
PS-RD04
Replacement oxygen (O2) sensor
SR-X10-C1
Replacement ozone (O3) sensor*
SR-G04
Replacement phosphine (PH3) sensor
SR-P04
Replacement sulfur dioxide (SO2) sensor
PS-RS04
For use with GAXT-X-DL-2 and GA-XT-DL-B-2 models.
Note: All sensors come with a 2 year warranty unless marked with an asterisk (*), denoting 1 year warranty.
Calibration & Testing Equipment
For calibration and testing equipment for this product, please see pages 86-89.
Manual Aspirator Pump
GA-AS02
Complete with probe, hose,
aspirator pump and adaptor cap
Sensor Screens
SamplerPak Kits
Kits include motorized sampling pump, batteries and
battery charger (if specified). See SamplerPak section for kit
contents, accessories and spares; detector sold separately.
5062-26-NCL-EN
GAXT-SS
7
GasAlert Extreme (continued)
A
B
C
D
E
F
G
Note: Please refer to the instrument’s documentation (shipped with the product or available at www.gasmonitors.com) for complete instructions on common service
procedures. Improper servicing or maintenance may affect warranty eligibility. Honeywell assumes no liability for damages resulting from improper servicing or maintenance.
8
5062-26-NCL-EN
GasAlert Extreme (continued)
Legend
B
G
A
D
C
Service Parts
Order Number
Replacement back enclosure (yellow) with screws
GAXT-BC1
Replacement back enclosure (black) with screws
GAXT-BC1B
Replacement front enclosure (yellow)
GAXT-FC1
Replacement front enclosure (black)
GAXT-FC1B
Replacement alligator-style clip with screw (stainless steel)
GA-AG-2
Replacement PCB, ammonia (NH3)
GAXT-A-DL-PCB1
Replacement PCB, ammonia (NH3), extended range, datalogging version
GAXT-A2-DL-PCB1
Replacement PCB, carbon monoxide (CO)
GAXT-M-DL-PCB1
Replacement PCB, carbon monoxide (CO-H), H2 resistant
GAXT-M2-DL-PCB1
Replacement PCB, chlorine (Cl2)
GAXT-C-DL-PCB1
Replacement PCB, chlorine dioxide (ClO2)
GAXT-V-DL-PCB1
Replacement PCB, ethylene oxide (ETO)
GAXT-E-DL-PCB1
Replacement PCB, hydrogen cyanide (HCN)
GAXT-Z-DL-PCB1
Replacement PCB, hydrogen sulfide (H2S)
GAXT-H-DL-PCB1
Replacement PCB, hydrogen sulfide (H2S), extended range
GAXT-H-2-DL-PCB1
Replacement PCB, nitric oxide (NO)
GAXT-N-DL-PCB1
Replacement PCB, nitrogen dioxide (NO2)
GAXT-D-DL-PCB1
Replacement PCB, oxygen (O2)
GAXT-X-DL-PCB1
Replacement PCB, sulfur dioxide (SO2)
GAXT-S-DL-PCB1
Replacement battery - lithium, 3V
E2829
Replacement bubble label, hydrogen sulfide (H2S)
GAXT-H-BLABEL
Replacement LCD holder with light pipe
GAXT-HLCD
Replacement LCD
GAXT-LCD
How to Replace the Battery
1. With detector OFF, use No. 1 Phillips
screwdriver to remove 4 screws from
back enclosure (B)
2. Lift back enclosure (B) straight up
3. Lift battery (C) straight up
4. Insert new battery (C)
5. Replace back enclosure (B)
6. Replace 4 screws in back enclosure
(B) and hand-tighten until firm
How to Replace the Sensor
1. With detector OFF, use No. 1 Phillips
screwdriver to remove 4 screws from
back enclosure (B)
2. Lift back enclosure (B) straight up
3. Use No. 1 Phillips screwdriver to
remove 2 screws from the back of the
PCB (D)
4. Lift PCB (D) together with battery (C)
and sensor (E) straight up
5. Remove sensor (E) from PCB (D) by
pulling straight up
6. Insert new sensor (E) into PCB (D)
7. Replace PCB (D) and 2 screws and
hand-tighten until firm
8. Replace back enclosure (B)
9. Replace 4 screws in back enclosure
(B) and hand-tighten until firm
How to Replace the Sensor Screen
1. With detector OFF, use No. 1 Phillips
screwdriver to remove 4 screws from
back enclosure (B)
2. Lift back enclosure (B) straight up
3. Use No. 1 Phillips screwdriver to
remove 2 screws from the back of the
PCB (D)
4. Lift PCB (D) together with battery (C)
and sensor (E) straight up
5. Remove sensor screen (F) from front
enclosure (G) by pulling straight up
6. Insert new sensor screen (F) into front
enclosure (G)
7. Replace board (C) and 2 screws and
hand-tighten until firm
8. Replace back enclosure (B)
9. Replace 4 screws in back enclosure
(B) and hand-tighten until firm
Note: Please refer to the instrument’s documentation (shipped with the product or available at www.gasmonitors.com) for complete instructions on common service
procedures. Improper servicing or maintenance may affect warranty eligibility. Honeywell assumes no liability for damages resulting from improper servicing or maintenance.
5062-26-NCL-EN
9
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising