Object Specification
Minerva80 v10
Operation
Introduction
A Minerva fire system [ M i n e r v a 8 0 v 1 0 ] is a Minerva 16, 16E or 80 fire alarm panel; or a network of fire panels. The
connected fire panel sends alarm events via its printer port and so limited information is available.
The interface will be unaware of the current panel state when connecting, so the panel(s) should be reset to re-send the
current alarm events.
Contents
The Minerva panel [ M i n e r v a 8 0 v 1 0 ] contains the following objects:
Object
Px [1]
Label
Panel x
R/W Value Type
[Minerva80 v10\Panel]
Notes
[1]
The panel number, x, is 1 when connecting to panel types 16/16E or 80. When connecting to a networked panel type it can be in the range 1...15.
Alarms
When alarms are generated by the Minerva panel [ M i n e r v a 8 0 v 1 0 ] they are written to the Alarm Object in the standard
format:
<Device Label>|<Object Label>|<Condition>|<Priority>|<Date>|<Time>
Where:
<Device Label> is the Point/Module device label
<Object Label> is the label of the Minerva object in alarm, and has the format:
Panel x Loop x
Panel x Loop x Dev x
Panel x Loop x Dev x Zone x
Panel x Zone x
<Condition> is the label of the current condition of the object in alarm. This text is passed directly from the panel
printer output. The following conditions are available:
Condition
SYSTEM RESET
SYSTEM RESTART
FIRE ALARM
FIRE EVACUATE
PREALARM WARNING
SUPERVISORY
FAULT CLEARED
A.S.U. FAULT
ALXM PSU FAULT
CP. WIRING FAULT
DET.WIRING FAULT
DEVICE FAULT
GENERAL FAULT
GROUND FAULT
LOOP DEVICE REVERSED
LOOP FAULT
LOOP O/C FAULT
LOOP S/C FAULT
LOOPS CROSS WIRED
MAINS FAILURE
NO RESPONSE
PSU.WIRING FAULT
SOUNDER EOL FAULT
SOUNDER FAULT
SOUNDER FAULT O/C
SOUNDER FAULT S/C
SYSTEM FAULT
Priority
1
1
1
1
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
North Building Technologies Ltd
web
tel
www.northbt.com
+44(0)1273 694422
Generated State
Clears all event states for panel
Clears all event states for panel
Fire
Fire
Pre-Alarm
Pre-Alarm
Clears fault state for device
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Condition
UNCONFIG DEVICE
WIRING FAULT O/C
WIRING FAULT S/C
Priority
3
3
3
Generated State
Fault
Fault
Fault
The panel will also generate other alarm conditions. These are sent using priority 3 and may include:
24V TOO HI FAULT
ACTIVATION WARNING
ALARM VERIFYING
ALARM WARNING
AUTOTEST ALARM
AUX. PSU FAULT
AUXILIARY ALARM
BATTERY CRITICAL
BATTERY FAULT
CHECKSUM FAILURE
CLEAR
CLOCK CLEARED
CLOCK SET
COINCIDENCE WARNING
COMMS FAULT
CONFIG FAILURE
CONFIG FINISHED
CONFIG INCOMPAT
CONTROL FAILURE
DATA ERROR x
DELAY STARTED
DET CON FAULT HI
DET CON FAULT LO
DET CON HI WARNING
DET CON LO WARNING
DISPLAY FAILURE
EARTH FAULT
ENGINEER LOG-OFF
ENGINEER LOG-ON
ENTRY ALARM
EVENT RESOUND
FAULT OVERFLOW
FIRE DOOR CLOSED
FIRE DOOR FAILURE
FIRE DOOR OPEN
FIRE DRILL
FIRETEST ALARM
HIGH IDENT
INPUT ACTIVE
INPUT OFF
INPUT ON
INTRUDER 24h ALARM
INTRUDER ALARM
INTRUDER FAULT
INTRUDER TAMPER O/C
INTRUDER TAMPER S/C
INVALID DATA
ISOLATE STATUS OFF
ISOLATE STATUS ON
ISOLATE WARNING
KEYPAD TAMPER
LOOP CRITICAL
LOOP FAULT& SHUTDOWN
LOOP WARNING
LOW IDENT
MANAGER LOG-OFF
MANAGER LOG-ON
MEDICAL ALERT
MNAU FAULT
NET COMMON FAULT
NET COMMS FAULT
NET GROUND FAULT
NET MODULE FAULT
NET PORT L FAULT
NET PORT R FAULT
NET RING CONT. FAULT
NET TRANSFER FAULT
NO PANEL RESPONSE
NOISE MEASUREM'T
NOISY DEVICE
NOT SET ALARM
OPERATOR LOG-OFF
OPERATOR LOG-ON
OUTPUT STUCK
PART SET
POINT ENABLED
POINT ISOLATED
POINT TESTED
POINT TESTMODE
PREMISES OCCUPIED
PREMISES UNOCCUPIED
PRINTER OFFLINE
PRINTER ONLINE
PROBATION ALARM
PROBATION FINISHED
PSU FAULT
RAID ALARM
RAM FAULT
RAM OVERFLOW
RELAY COIL FAULT
RESET INPUT
S251 RANGE WARNING
SATURN GROUP OFF
SATURN GROUP ON
SECTOR DISABLED
SECTOR ENABLED
SET TIMEOUT
SHUNT OFF
SHUNT ON
SIGNAL. DELAY OFF
SIGNAL. DELAY ON
SIGNALLING ENABLED
SIGNALLING FAULT
SIGNALLING ISOLATED
SYSTEM SET
SYSTEM SILENCE
SYSTEM UNSET
TAMPER ALARM
TAMPER FAULT HI
TAMPER FAULT LO
TEST FINISHED
TEST STARTED
UNCONFIG PANEL
UNSET WARNING
UNSUPERVISED PANEL
WATERFLOW ALARM
WEEKLY TEST DUE
XBUS FAILURE
ZONE ENABLED
ZONE ISOLATED
<Priority> is the priority assigned to the alarm condition (see above)
<Date> is the date the condition was detected by the panel, in the format dd/mm/yy
<Time> is the time the condition was detected by the panel, in the format hh:mm:ss
Examples:
“Minerva Fire System|Panel 1 Loop 1 Dev 5|NO RESPONSE|3|19/12/96|13:00:00”
“Minerva Fire System|Panel 1|SYSTEM RESET|1|19/12/96|13:10:00”
“Minerva Fire System|Panel 1 Loop 1 Dev 3|FIRE ALARM|1|20/12/96|13:01:00”
This document is subject to change without notice and does not represent any commitment by North Building Technologies Ltd.
© Copyright 1998-2009 North Building Technologies Limited. All Rights Reserved. Issued 14/10/2009.
Object Specification – Minerva80 v10
2
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising