Interior P atient Room
HPT8
SPECIFICATIONS
The Trilume LED product provides facility managers with a clean look and efficient fixture option for LED patient room lighting. The Trilume LED provides the light output of a traditional fluorescent patient room fixture
but with reduced energy. Ambient mode can be specified for side or center illumination. The Trilume LED combines the advanced digital control technology of nLight with the legacy technology of existing bedside
controls. Includes 1/8” thick Sanitary Lens to help seal the fixture within the patient room.
CONSTRUCTION
20 GA cold rolled steel housing
Nominal 2' and 4' lengths available
FINISH
Polyester powder coat painted after fabrication
Antimicrobial or Custom Color are optional
SHIELDING
1/8" clear acrylic lens standard
SOURCE
LED - 3000K, 3500K, 4000K & 5000K available
Voltage
120V or 277V
Input Watts
Max Input Watts for 2x4
Center Only: 87W
Side Only: 89W
All on (Exam Mode): 176W
Dimming
0-10v smooth, flicker-free dimming minimul level
1% standard
Dim to dark option available
Color Quality
CRI >80
R9 Value 19
Life Estimate
L80 at 65,000 hours
Light Output
See table on page 2
LISTINGS
CSA Certified to meet US and Canadian standards
Warranty
5-year limited warranty. Complete warranty
terms located at: www.AcuityBrands.com/
CustomerResources/Terms_and_Conditions.aspx
NOTE: Actual performance may differ as a result of
end-user environment and application.
All values are design or typical values, measured
under laboratory conditions at 25°C.
Specifications subject to change without notice.
A+ Capable options indicated
by this color background.
CATALOG NUMBER
Example: HPT824 F 120 CAHI NFI LED40 CRI80 NFI SX ZT MIN1 SL MWAM
Series
HPT822
HPT824
2x2 fixture
2x4 fixture
Mounting
Voltage
Output
F
G
120 120V
277 277V
CALOW
CAMED
CAHI
SALOW
SAMED
SAHI
CALNS
CAMNS
CAHNS
1
Flange
Grid
Center basket ambient, low output
Center basket ambient, medium output
Center basket ambient, high output
Side lights ambient, low output
Side lights ambient, medium output
Side lights ambient, high output
Center basket ambient, low output, no side lights
Center basket ambient, medium output, no side lights
Center basket ambient, high output, no side lights
Center Lens Insert
Led Color
Color Rendering
NFI
PAI
LED30
LED35
LED40
LED50
CRI80
CRI90
No insert
Perforated
acrylic insert
WAV Wave pattern
acrylic insert
3000K
3500K
4000K
5000K
Patient Controls
Controls
Minimum Dimming Level
Door Options
Finish7
SX No patient control
LVD2 Low voltage digital controller, 4
position sequential switching
ZT
NIOAM3
NIOEX4
NIOAE5
MIN1
DARK6
SL
MW
MWAM
0-10V control
nLight enabled ambient mode
nLight enabled exam mode
nLight enabled ambient and exam mode
Minimum dimming level 1%
Minimum dimming level <1%
Door with sanitary
lens (standard)
80+ CRI
90+ CRI
Matte white
Matte white
antimicrobial
Notes
1.
2.
3.
4.
5.
Flange construction ships standard with Lithonia DGA adapter.
When LVD is selected, factory provides only wire leads exiting the fixture.
When ordered nLight enabled in ambient mode, nIO comes programmed to channel 1.
When ordered nLight enabled in exam mode, nIO comes programmed to channel 2.
When ordered nLight enabled in ambient and exam mode, nIOs are daisy-chained
within the fixture. Ambient mode will be programmed to channel 1 and exam mode
programmed to channel 2.
6. If 2x2 fixture (HPT822) is ordered with minimum dimming level "DARK", fixture must
be ordered without patient control (SX), with 0-10V control only (ZT), and may not
include night light (LNL) due to spatial limitations.
7. NSF listing applies to MWAM finish only.
Healthcare Lighting • (888) 834 5684 • www.healthcare-lighting.com
© 2015-2017 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting. Products herein may be
covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Rev. 02/21/17
TRILUME PCX
1
Project:
Trilume PCX
Type:
Patient Room Recessed Lighting
Qty:
ORDERING NOTES
Interior P atient Room
HPT8
PERFORMANCE DATA
Lumen Output
Lumen values are from photometric tests from an accredited laboratory. Data is considered to be representative of the configurations shown, within generally accepted industry tolerances. Actual
performance may differ as a result of end-user environment and application. Contact factory for performance data on any configurations not shown here.
Center
Ambient
Side
Ambient
Center
Ambient
No Sides
Nomenclature
Setting
Lumen
Output in
Ambient
Mode
Input
Watts
CALOW
CAMED
CAHI
SALOW
SAMED
SAHI
CALNS
CAMNS
CAHNS
Low
Medium
High
Low
Medium
High
Low
Medium
High
3671
6859
8954
2642
4937
6445
3658
6834
8922
37.8
68.7
91.9
37.6
68.8
92.1
37.8
71.7
94.9
2x4
Footcandles Lumen
from 6 feet Output
LPW Above Bed in Exam
(Ambient
Mode
Mode)
(All On)
97
38 FC
10255
100
71 FC
13499
97
93 FC
15631
70
21 FC
11753
72
41 FC
14034
70
53 FC
15533
97
38 FC
95
71 FC
94
93 FC
-
Input
Watts
LPW
Footcandles
from 6 feet
Above Bed
(Exam Mode)
Lumen
Output in
Ambient
Mode
Input
Watts
LPW
124.2
155.1
178.3
123.8
155.0
178.3
-
83
87
88
95
91
87
-
92 FC
121 FC
140 FC
116 FC
139 FC
154 FC
-
1585
2962
3867
1141
2132
2783
1580
2952
3853
16.5
27.6
46.7
16.3
28.8
38.2
16.5
27.6
46.7
96
107
83
70
74
73
96
107
82
2x2
Footcandles Lumen
from 6 feet
Output
Above Bed in Exam
(Ambient
Mode
Mode)
(All On)
16 FC
4390
31 FC
5779
40 FC
6691
9 FC
5031
17 FC
6008
23 FC
6649
16 FC
31 FC
40 FC
-
Input
LPW
Watts
55.9
66.9
86.1
55.8
68.3
77.6
-
79
86
78
90
88
86
-
Footcandles
from 6 feet
Above Bed
(Exam Mode)
40 FC
52 FC
60 FC
50 FC
60 FC
66 FC
-
*Nominal values, typical at 3000K, 80 CRI
CONTROLS
nLight® Control Accessories:
Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlight.
WallPod stations
On/Off
On/Off & raise/lower
Graphic touchscreen
Photocell controls
Full range dimming
Model number
nPODM [color]
nPODM DX [color]
nPOD GFX [color]
Model number
nCM ADCX RJB
Occupancy sensors
Small motion 360°, ceiling (PIR / dual tech)
Large motion 360°, ceiling (PIR / dual tech)
Wall switch with raise/lower
Cat-5 cable (plenum rated)
10' cable
30' cable
Model number
nCM 9 RJB / nCM PDT 9 RJB
nCM10 RJB / nCM PDT 10 RJB
nWSX PDT LV DX [color]
Model number
CAT5 10FT J1
CAT5 30FT J1
Capable Luminaire
This item is an A+ capable luminaire, which has been designed and tested to
provide consistent color appearance and out-of-the-box control compatibility with simple commissioning.
• All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency
• This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with
drivers marked by a shaded background*
• This luminaire is part of an A+ Certified solution for nLight control networks, providing advanced
control functionality at the luminaire level, when selection includes driver and control options marked
by a shaded background*
To learn more about A+, visit www.acuitybrands.com/aplus.
*See ordering tree for details
Healthcare Lighting • (888) 834 5684 • www.healthcare-lighting.com
© 2015-2017 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting. Products herein may be
covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Rev. 02/21/17
TRILUME PCX
2
Project:
Trilume PCX
Type:
Patient Room Recessed Lighting
Qty:
ORDERING NOTES
Interior P atient Room
HPT8
DIMENSIONS
Housing Length
2 1/2"
3 1/2"
3/8" Threaded Rob
(By Others)
23 1/4"
Secure For Plenum with Tie Wire
(By Others)
13 1/2"
Thermal
Protector
2 1/8"
Flange Length
Housing Length
5 3/4"
23 3/4"
2x2 Length x Width
2x4 Length x Width
Nominal
2' x 2'
2' x 4'
Actual
23.75" x 23.75"
23.75" x 47.75"
Flange Length
23.75"
47.75"
Housing Length
22.53"
46.53"
Flange Length
MOUNTING
Notes (see Installation Instructions for more details):
1. Use support tie wires or 0.375" rod to secure housing to ceiling infrastructure (by others).
2. For sheet rock installation, fixture ships with Lithonia DGA Frame.
3. DGA Frame dimensions shown in table below.
#12 GA. Mild Steel Support Wire
4-Places (by others)
Support Wires
Ceiling Support
‘C’ Shape Runner
(by others)
Extruded Aluminum
Frame with Mitered Corners
A
A
B
Ceiling Opening Width
B
Trim O.A. Width
E
Fixture Size
2x2
2x4
Ceiling Cutout
A
B
24 7/8” 24 7/8”
24 7/8” 48 7/8”
Optional
Mounting Holes
E
Tile
(by others)
Nomenclature
DGA22
DGA24
Fixture Size
Nominal
2x2
2x4
Optional Mounting Holes
(.25 Dia.) 3- per side
Width
A
B
24-7/8"
25-3/8"
24-7/8"
25-3/8"
Length
C
D
24-7/8"
25-3/8"
48-7/8"
49-3/8"
E
9"
21"
1.06"
C Ceiling Opening Length
D Trim O.A. Length
Healthcare Lighting • (888) 834 5684 • www.healthcare-lighting.com
© 2015-2017 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting. Products herein may be
covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Rev. 02/21/17
TRILUME PCX
3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising