Technical data
Protection class:
Dimensions:
Weight:
Fastening:
Temperature range:
Power supply:
Power consumption:
XENON
GSM modem:
XENON-zz/zm
count frequency:
input contact:
IP68
122 x 120 x 55 mm
approx.475 g
4 screws
-20 °C to +55 °C
lithium battery 3.6 V
stand-by:
max.0.04 mA
active:
approx.30 mA
transmitting: 250 mA max.
CE 0681
max. 15 Hz
Uo 3,6 V / I0 36 µA
ULOW <= 0,5 V / UHIGH >= 2 V
Battery note
GSM Reading of
water and heat meters
●
●
●
●
Interface for Sensus meters
Integrated GSM modem
Integrated dual band antenna
Power supply by internal battery
Supplied items
●
●
●
●
●
●
Availabe versions
SIM
pulse
card
input
contract
XENON-zz
X
2
alarm
input
Manufacturers’ declaration
MiniBus order
number
—
—
18 40 13
XENON-zm
X
1
1
—
18 40 14
XENON-MB
X
—
—
2
18 40 15
XENON-zz
—
2
—
—
18 40 17
XENON-zm
—
1
1
—
18 40 18
XENON-MB
—
—
—
2
18 40 19
Accessories
Example of status answer “ok”:
(2 MiniBus meters)
== Status == Do 10.03.04 10:08:38+01*
ID0:00011111111 V0:00000007968
ID1:0001234567 V1:000000029540
Batt:03,62V Pegel:96% Reset:01,00,00,00
Example of status answer “not ok”:
== Status == Do 10.03.04 10:08:38+01*
ID?0:00011111111 V?0:00000007968
ID?1:0001234567 V?1:000000029540
Batt:03,62V Pegel:96% Reset:01,00,00,00
?stands for meter unknown/values are last status
LED displays
Soon after activation the LED's will illuminate and on
MiniBus versions the external LED including the SNDLED and REC-LED will illuminate initially.
Position of LEDs (left side)
yellow Modem
yellow Extern
green SND
green REC
Magnetic
relay
Status of modem
Cable connection
Cables of MiniBus versions: signal (red cable) and GND
(black cable). Cables of variants -zz/-zm: GND (black cable),
input 1 (white cable) and input 2 (yellow cable). Inputs can
optionally be connected with one cable or with both cables,
but a double connection of inputs must be avoided.
Installation table
Version
Input 1
Input 2
XENON MiniBus
MiniBus1
MiniBus2
IP68 junction box
18 20 73
XENON-zz
pulse meter 1
pulse meter 2
IP68 plug
18 20 74
XENON-zm
pulse meter
alarm contact
BPZ-Sensus-XENON/03-03-2005/V1.5/engl.
Status inquiry: „Status_+49172xxx“
The _ (dash) after Status indicates a blank space,
xxx must be replaced by the WIKON module’s number
Note: The answer will be the last data stored on the server. The call line identification presentation (CLIP)
has to be activated on the mobile phone. For the
previous update of the data on the server use
the magnetic switch.
WIKON Kommunikationstechnik GmbH
www.wikon.de
Description of component
XENON is a battery operated instrument for remote data
reading based on GSM-SMS technology
Applied standards
The manufacturer declares that the specified component
is produced in accordance with following standards:
EMV directives:
EN61000-4-3 radiated RF immunity
EN55011 A radiated RF emissions
EN61000-4-4 burst immunity of data lines
EN61000-4-6 conducted RF immunity of data lines
EN61000-4-2 ESD
Xenon module
Battery,ready for use
Internal antenna
IP68 protection of casing
Magnet for magnetic switch
Enclosure with fastening brackets
Version
WARNING - The device contains a lithium battery. The battery
must not be forcefully opened, recharged, short-circuited,
exposed to contact with water or sustained temperatures above
80 °C. Depleted batteries, redundant electronic equipment or
components are regarded as hazardous waste and should be
disposed of at suitable collection points.
Status inquiry via mobile phone
In order to receive information the following SMS text
command can be sent by mobile phone to the WMH
server (+49172 8484176):
modem
external
SND
REC
remarks
yellow LED yellow LED green LED green LED
on
off
on
on
searching for
GSM network
blinking
off
on
on
network found
blinking
off
on
off
sending SMS
blinking
off
off
on
receiving SMS
blinking
off
off
off
OK, i.e. all SMS sent
and received
off
off
off
off
standby
Installation and starting operation
Casing protection is IP68. In order to maintain IP68 conditions, the casing may not be opened.
1. MiniBus version: check MiniBus addresses:
Set the main meter to MiniBus address 0. If a
second meter is to be connected, this meter is to be
set to address 1. ➠ avoid designating identical
addresses to different meters!
2. Connection of cable:
Connect the cable according to the installation table.
Use an installation box suitable for IP68 (e.g. available Sensus accessory).
Secure the enclosure so that it is possible to alter its
position - should this become necessary.
3. Activation:
Pass the magnet along the left side of the enclosure.
The XENON unit is activated as soon as the LED's are
illuminated. Approx. 3 minutes later there will be a
status acknowledgement to the server.
4. Reception test:
As soon as all LEDs of XENON are off again, you
should run a reception test by sending the SMS command „Status_+49172xxx“ via mobile phone to the
WMH server. (xxx stands for terminal number
the _ (dash) indicates a blank space)
5. Level check:
If the level of the returned message on the mobile
phone is <30%, find another position for the instrument. Activate the instrument again using the magnet and repeat the procedure.
6. Fastening:
Once you have located a position with a suitable signal level, fasten the device to the wall, or suspend
the unit using the fastening brackets. Ensure that the
cable entry glands face downwards.
Sensus Metering Systems GmbH
Meineckestraße
30880 Laatzen
Tel.: +49 (0)5102/74-0
Fax: +49 (0)5102/74-341
Internet: www.sensus.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising