N-8000 Series IP Intercom System Brochure

N-8000 Series IP Intercom System Brochure
N-8000 SERIES
IP INTERCOM SYSTEM
All-Purpose IP Intercom System with
TOA’s Advanced Packet Audio Technology
Assuring Higher Levels of Security,
Versatility and Sound Quality
A versatile, highly reliable IP intercom
for flexible, cost-effective c
TOA’s unique N-8000 IP Intercom System is an integrated audio
communication system that employs packet audio technology over the IP
network to achieve fast, accurate communications with optimal security and
reliability. Applications range from conversation, paging broadcasting and
BGM broadcasting to emergency paging and broadcasting, audio triggering
and other security functions. Users can select between two communication
modes according to their needs: Master-to-Master station communication for
duplex conversation at factories, hospitals and various other facilities; or
Master-to-Sub station communication for use by institutions such as schools
or prisons. The system frequency response extends to 7 kHz, enabling
reliable transmission of a full range of emergency communications, including
clear, easily understandable PA announcements.
The N-8000 System’s impressive scalability enables users to configure an
intercom system that satisfies their precise requirements, from a small
system with just two stations to a large, complex system with up to 192
components and 3,072 stations. Its open architecture permits flexible
interfacing with other systems, moreover, reducing costs by enabling users to
upgrade and expand their intercom system without replacing currently
installed equipment, such as surveillance cameras, telephones and access
controls. Since the N-8000 System is not server based, users can use
dedicated TOA software to manage settings and centralized control on a PC
and to conduct real-time monitoring of system operation and line status using
an Internet browser.
1
m system designed to meet user needs
configuration and operation
System Features
• System configuration by LAN with intuitive
software
• Master-to-Master and Master-to-Sub station
communication
• Choice of three wiring configurations: 2-core
shielded cables, 2 wires or 4 wires
• Integration with access control, voice alarm,
CCTV and other such systems
• Ambient noise control • Time correction
• Operation and stream logs
• System diagnosis
Basic
Communication
Features
• Handset or hands-free conversation
• Recall • Redial • Camp on busy • Mic-Off
• Remote response • Single-digit dialing
• Call transfer • Comprehensive callforwarding features
• Three-party conferencing
System scalability
The cost-effective N-8000 System can be
configured to a scale that meets users’ specific
requirements, however small or large. As few as
two stations can be linked in a small system, or up
to 192 components can be interconnected to
operate as many as 3,072 stations.
Borderless communications
Since the N-8000 System is IP network-compatible,
it supports linkage between local areas and other
locations worldwide. Centralized PC control with
dedicated TOA software enables connection of all
exchanges, IP stations and interface units with
LAN, WAN and optical fiber networks.
Integrated communications and
safety features
Efficient centralized control integrates various
systems to handle communications ranging from
duplex conversations between stations to paging
broadcasts, scheduled broadcasts and BGM
broadcasting. The N-8000 System also provides
master control for connection to users’ pre-existing
intercom, alarm, surveillance, door entry/departure
authorization and other systems as well as to
telephone lines.
Easy installation and maintenance
The surprisingly easy system installation requires a
minimum of on-site work, since existing wiring can
be used and new components simply plugged in.
The dedicated TOA software includes a
maintenance application for system status
monitoring, troubleshooting and logging as well as
for system updating and remote control.
Long-term cost-effectiveness
Since N-8000 software and all calls between
stations are free of charge, users enjoy the benefit
of significantly lower telephone bills. Overall
ownership costs are also reduced by the
open-ended system architecture and network
scalability permitting individualized configuration.
Superior sound quality
The N-8000 system provides high-quality audio for
BGM, paging and recording applications.
Full logging options
The complete menu of operation and stream
logging options includes operation verification,
voice communications and line supervision logs,
all of which can be archived easily for instant recall.
Internal and external system
security
The N-8000 System is equipped with both a
round-the-clock internal surveillance function to
minimize downtime and a packet audio protocol to
prevent wiretapping.
2
N-8000 System Overview
N-8510MS
N-8600MS
LAN
N-8640DS
Speaker
Door control
Speaker
AD-1210P*
AD-1210P*
AD-1210P*
* No AC adapter required when
connected to a PoE-compatible
switching hub
Direct Network Connection
N-8000EX / 8010EX
Speaker
PA Amplifier
N-8020MS
N-8033MS
Foot Control Switch
N-8000MS
N-8010MS
Revolving Light
Speaker
RS-191
N-8031MS
N-8011MS
Speaker
2-Wire Connection
N-8050DS
Door Control
Foot Control Switch
System Specifications
LAN Connections
BGM
Max. 192 units (total no. of Exchanges,
Interface Units and IP stations)
Max. 8 channels (number of channels
selectable from a station)
Station Connections
PBX Interface
Max. 3,072 stations (16 stations
connected to each of 192 Exchanges)
Max. 384 units (2 units for each of 192
connected Multi-Interface units)
Voice Links
Tie-Line Interface
Max. 768 links (4 links for each of 192
connected N-8000EX Exchanges)
Max. 384 units (2 units for each of 192
connected Multi-Interface units)
Paging
Office-Line Interface
Zones
Max. 192 zones
Paging Outputs
Max. 384 outputs (2 outputs for each of
192 connected N-8000 Exchanges or
Multi-Interface units)
3
Max. 192 units (when 192 Office Line
Interface units are connected)
Telephone Interface
Max. 192 units (when 192 Telephone
Interface units are connected)
External Contact Output
[Network Relations]
N-8000MI
Max. 3,072 (16 inputs for each of 192
connected Multi-Interface units)
N-8000DI
Max. 6,144 (32 inputs for each of 192
connected Direct Select units)
N-8000AF
Max. 1,536 (8 inputs for each of 192
connected Audio Interface units)
Audio Delay Time
80 ms/320 ms; changeable
External Contact Input
Max. 130 kbps (two-way)/per call
N-8000MI
Max. 3,072 (16 inputs for each of 192
connected Multi-Interface units)
N-8000DI
Max. 6,144 (32 inputs for each of 192
connected Direct Select units)
N-8000AF
Max. 1,536 (8 inputs for each of 192
connected Audio Interface units)
Connection Delay Time
Max. 1 second (when 191 multicast
paging destinations are set)
Bandwidth Used
Max. 208 Mbps (one-way)/unicast paging
to 16 locations
WAN
N-8400RS
N-8000AF
N-8000DI
N-8410MS
RS-450
Digital announcer
Amplifier
RS-460
Contact
Input
Contact
Output
TERMINAL BOARD UNIT E-7000TB
Terminal Board
Recorder
RS-470
RS-480
N-8000MI
Speaker
Revolving Light
RS-481
N-8000AL
4-Wire Connection
Contact
Input
Digital Announcer
N-8000RS/8010RS
Contact
Output
Analog Telephone
Amplifier
PBX
RS-150
N-8000CO
Speaker
EXES-7000/6000/2000
Permits the creation of a wide
variety of system configurations
through the free combination of
individual interface units
• PBX Connection • Office line connection
• Tie-line connection • BGM
• External equipment control
• Remote door control • Conversation recording
• External input broadcast • Paging
• Paging interlock contact output control
• Call station indicator • CCTV interlock
• Remote dialing • Direct select
• Contact bridge • System diagnosis
• Time signal • Time correction
RS-160
RS-170
Telephone
A variety of convenient functions
• Voice calling
• Hands-free conversation
• Automatic connection
• Continuous call
• One-touch dialing
• Call hold
• Automatic call forwarding
• Busy call
• Emergency call interruption
• Paging call
• Emergency all-group paging
• Emergency message broadcasts
• Paging response
• Scan monitor
• Three-party conference
• Door remote
• Emergency paging
• Audio trigger
RS-180
RS-140
RS-143
RS-144
RS-141
Speaker
2-Core Shielded Wire Connection
4
Application Examples
Hospital
Employee exit
Operation Room -1
Operation Room -20
N-8000EX
N-8033MS
Electric Lock,
for unlocking, etc.
Door Station
N-8050DS
N-8033MS
N-8033MS
N-8000EX
N-8033MS
Foot Control Switch
(1 station)
Foot Control Switch
(3 stations)
Control room
SW HUB
N-8011MS
N-8000DI
Indication Board LED
Pilot Lamp
School
Secretary's office
N-8510MS
Emergency Switch
Caretaker's room
N-8510MS
Emergency Switch
RS-180
RS-180
Speaker
Classroom
Speaker
Revolving
Light
RS-160
RS-160
RS-143
RS-140
N-8000RS
Broadcasting booth
Faculty room
HUB
N-8000EX
CCTV
Contact Out
Gate operation (open)
N-8000AF
N-8000MS
Amp
5
N-8000MS
N-8010MS
Bank
Security office
Monitoring center
Monitoring center
Control center
7:00~24:00
24:00~7:00
Forward busy
N-8600MS
Nighttime transfer
N-8600MS
N-8600MS
RS-170
TOA
LAN
N-8000RS
Intercom
TOA
system
Intercom
•••
system
N-8640DS
ATM
Intercom
system
Speaker
TOA
Intercom
RS-170
N-8640DS
system
•••
TOA
Speaker
system
RS-170
TOA
Speaker
Intercom
TOA
N-8640DS
Intercom
system
N-8640DS
ATM
ATM
Factory
Entrance
Administration office
CCTV
N-8000EX
HUB
N-8640DS
N-8000MI
Monitor
Production floor
N-8000MS
Laboratory
N-8000DI
Pilot Panel
N-8000EX
N-8000EX
N-8031MS
N-8031MS
Foot Control Switch
N-8020MS
Speaker
Call Signal
Amp
Speaker
N-8000MS
Speaker
N-8020MS
N-8000MS
N-8050DS
6
Parking garage
Parking area
3F
RS-480
CCTV
2F
RS-480
CCTV
1F
RS-480
CCTV
N-8400RS
HUB
Router
Secretary's office
Recorder
N-8000AF
N-8000DI
N-8600MS
HUB
LAN
PC for monitoring
N-8000CO
Router
Telephone
Security company
7
Station Selection Chart
Master/
Door Stations
IP Base
Desk-top
Applicable
Exchanges/
Interfaces
Wall-mount
Optional
Bracket
YC-280
N-8600MS
N-8640SB
YC-280
N-8640DS
N-8510MS
N-8650DS
Master/Door Stations
2-Wire Type
YC-280
N-8000MS
N-8050DS
YC-280
N-8000EX
N-8010MS
YC-290
N-8031MS
N-8033MS
N-8011MS
N-8010EX
YC-280
N-8050SB
N-8031SB
Vandal-resistant
type
RS-150
N-8000RS
RS-160
RS-140
RS Sub-stations
4-wire Type
2-core Shielded Type
N-8020MS
RS-170
N-8010RS
RS-144
RS-180
RS-143
YC-280
N-8410MS
RS-450
RS-460
RS-470
N-8400RS
RS-480
Outdoor type
8
Key Functions
Paging Function Allows the master station as well as external input equipment to initiate
paging by PA equipment or the speakers of individual stations. Operators can use the setup software
to configure up to 192 paging zones to which paging calls can be made as desired.
N-8600MS
WAN
LAN
Internet
IP-VPN
or
N-8600MS
N-8000AF
PA Amplifier
Speaker
N-8000MI
Remote Control of External System
Makes it possible to execute door lock
control easily through a contact output when the master station is engaged in ongoing conversation
with the N-8640DS or N-8050DS Door Station.
WAN
LAN
N-8000MS
Privacy Mode
N-8000EX or N-8010EX
Internet
IP-VPN
N-8000MI
Door Control
Activated by a control on the RS-140 Switch Panel, blocks paging calls to
connected speakers and prevents scan monitoring except for emergency calls.
WAN
LAN
X
Internet
IP-VPN
N-8000RS or N-8010RS
N-8600MS
Direct Select
Speaker
RS-140
Configures an operation panel equipped with indicator lamps and control
buttons for the master station. Compatible with other stations, the panel assigns the various contact
input and output channels to the master station and substations for purposes of identifying which
substation is calling the programmed master station.
WAN
LAN
Pilot Panel
N-8000DI
N-8000DI only
Internet
IP-VPN
N-8640DS
9
Scan Monitor
Enables remote security monitoring by allowing the master station as well as
analog telephones and external telephones to audio monitor two or more pre-programmed stations.
N-8600MS
N-8000EX
N-8000MS
WAN
LAN
Internet
IP-VPN
N-8640DS
N-8000EX
N-8000MS
N-8000RS
RS-180
BGM Broadcasting
Enables music from any of eight BGM sources connected to
the N-8000MI to be distributed through speakers at the master and door stations.
N-8000MS
Sound Source
N-8000MS
WAN
LAN
CD player
MP3 player
MD player
N-8000MI
Internet
IP-VPN
N-8000EX or N-8010EX
or
N-8000AF
PA Amplifier
Speaker
N-8600MS
N-8600MS
Audio Trigger
Sets off an alarm if audio input to a pre-programmed station’s microphone fulfils
pre-set conditions (detection time or signal level). Examples include calls to the designated master
station or contact output generated by another interface unit.
WAN
LAN
N-8050DS
N-8000EX
N-8000MS
Internet
IP-VPN
N-8050DS only
N-8000 MI
or
N-8000DI
Revolving Light
10
IP Base
Station
IP Multifunctional
Master Station
N-8600MS
Power Source
Power Consumption
Speech Method
Audio Frequency Range
Contact Input
Contact Output
External Speaker Terminal
External Control Input
Terminal
Network Section
Network I/F
Network Protocol
Audio Packet
Transmission System
Voice Packet Loss Recovery
Audio Delay Time
Dust/Water Protection
Finish
Dimensions
Weight
Option
IP Door Station
IP Standard
Master Station
N-8510MS
IP Door Station Board Unit
IP Door Station
N-8640DS
N-8650DS
N-8640SB
Power supply device that complies with IEEE802.3af standard or 12V DC (supplied from the AC adapter (option))
3W (max.)
6W (max.)
5W (max.)
Hands-free or handset conversation
Hands-free conversation
300 Hz – 7 kHz
1 channel, no-voltage make contact input, open circuit voltage: 5V DC,
—
short circuit current: 10mA or less, unterminated ends
—
Open collector output, 4 channels, withstand voltage: 30V DC,
control current; Max. 50mA (4 output 1COMMON), unterminated ends
Relay contact output, 1 channel, withstand voltage; 30V DC.
control current: Max. 500mA, unterminated ends
0.5W, 8Ω
—
0.5W, 8Ω
—
No-voltage contact input,
—
open voltage: 5V DC
short-circuit cuttent: 5mA ot lrss,
screwless connector (2 pins)
10BASE-T/100BASE-TX (Automatic-Negotiation)
TCP/IP, UDP, ARP, ICMP, HTTP, RTP, IGMP
Unicast, Multicast
Silence insertion
80ms, 320ms (controllable on the software)
IP65 (Note that panel edges must be
—
—
—
sealed at installation.)
Body, Handset: ABS resin, gray
Panel: Stainless steel (SUS304),
ABS resin, dark gray
hairline/
Call button: Metal
115 (W) x 162 (H) x 58.5 (D)mm 117.2 (W) x 162 (H) x 60 (D)mm
148 (W) x 208 (H) x 70.5 (D)mm (excluding a curl cord section)
770g
740 g
780g
400g
For flush-mount: 3-gang electrical box or Back Box YC-150,
Wall mounting bracket: YC-280, AC adapter: AD-1210P
Wall surface-mount: Wall mount Box YS-13A,
AC adapter: AD-1210P
—
—
79 (W) x 134 (H) x 53 (D)mm
350g
AC adapter: AD-1210P
*0dB = 1V
Multi Interface Unit
N-8000MI
Power Source
Power Consumption
Audio Input
Audio Output
Contact Input
Contact Output
Network Section
Network I/F
Network Protocol
Audio Packet
Transmission System
Voice Packet Loss Recovery
Audio Delay Time
Finish
Dimensions
Weight
Options
*0dB = 1V,
11
24W (230mA) (max.)
Input: 2 inputs (2P/input), Max. 0dB*, under 600, balanced,
with a semi-fixed volume for adjustment (0 to –25dB)
Control: 2 inputs (2P/input), no-voltage make contact input,
open voltage: 12V DC, short-circuit current: 10mA
Removable terminal block (8 pins)
Output: 2 outputs (2P/output), Max. 0dB*,
under 600, balanced
Control: 2 outputs (2P/output), relay contact output,
contact capacity: 24V DC/0.5A
Removable terminal block (8 pins)
16 inputs, no-voltage make contact input, open voltage;
12V DC, short-circuit current: 10mA, removable terminal
block (18 pins)
(1 common terminal for 4 inputs)
16 outputs, relay contact output, contact capacity: 24V DC/
0.5A, removable terminal block (18 pins)
Audio Interface Unit
Direct Select Unit
N-8000DI
220 – 240V AC, 50/60Hz
16W (Max.)
—
—
N-8000AF
7W (Max.)
1 input (transformer isolated), -58dB* to 0dB*, 2k, balanced
(MIC/LINE input, controllable on the software)
with input volume control knob, removable terminal block
(3 pins)
1 output (transformer isolated), 0dB*, 600, balanced,
removable terminal block (3 pins)
32 inputs, no-voltage make contact input, open voltage:
24V DC, short-circuit current: 5mA or less,
removable terminal block (20 pins),
8 inputs, no-voltage make contact input, open voltage:
24V DC, short-circuit current: 5mA or less, removable
terminal block (10 pins), (1 common terminal for 4 inputs)
32 outputs, relay contact output, contact capacity: 24V DC/
2 – 500mA, removable terminal block (32 pins)
8 outputs, relay contact output, output capacity: 24V DC/
2 – 500mA, removable terminal block (16 pins)
10BASE-T/100BASE-TX (Automatic-Negotiation)
TCP/IP, UDP, ARP, ICMP, HTTP, RTP, IGMP
Unicast, Multicast
—
Silence insertion
—
80ms, 320ms (Controllable on the software)
—
Pre-coated steel plate, black, 30% gloss
420 (W) x 44.3 (H) x 267 (D)mm
420 (W) x 44.3 (H) x 239.5 (D)mm
2.8kg
2.8kg
Wall mounting bracket: YC-850
Unicast, Multicast
Silence insertion
80ms, 320ms (Controllable on the software)
210 (W) x 44.3 (H) x 267 (D)mm
1.7kg
Rack mounting bracket: MB-15B-BK, MB-15B-J
Wall mounting bracket: YC-850
2-Wire Type
Station
Multifunctional
Master Station
Standard
Master Station
Industrial-Use
Master Station
Standard
Hands-Free
Master Station
Flush-Mount
Hands-Free
Master Station
Flush-Mount
Master Station
Door Station
RS-191
N-8000MS
Power Source
Power Consumption
Wiring Method
Speech Method
Audio Frequency Range
Transmission Range
Dial-in Contact Output
N-8010MS
N-8020MS
N-8011MS
N-8033MS
N-8031MS
N-8050DS
48V DC (supplied from the IP network intercom exchange)
2.4W (max.)
1 set of twisted pair cable
Hands-free or handset conversation
Hands-free conversation
300 Hz – 7k Hz
Max. 1500m (ø0.65mm. Loop resistance 170)
Open collector output
(The contacts have polarity.)/
—
—
—
—
—
Withstand voltage: Max. 30V DC,
Control current: Max. 50mA,
screwless connector (2P)
—
Contact Output
External Dial Input
External Speaker Terminal
Dust/Water Protection
Resistance to Environment
Finish
Dimensions
Weight
Options
—
—
—
—
—
—
—
—
0.6W, 8, screwless
connector (2P)
—
—
0.6W, 8, screwless
connector (2P)
IP54
—
—
—
170 (W) x 220 (H) x
97.8 (D)mm (excluding
a curl cord section)
1kg
92 (W) x 195 (H) x
56.1 (D)mm
—
—
—
Body, Handset: ABS resin, gray
148 (W) x 208 (H) x 70.5 (D)mm
(excluding a curl cord section)
800g
700g
Wall mounting bracket: YC-280
—
—
No-voltage make contact input, open voltage: 5V DC,
short-circuit current: 1mA, screwless connector (5 pins)
—
—
IP65 (Note that panel edges
—
must be sealed at installation.)
Chemical Resistant
—
Membrane switch
Panel: Stainless steel
(Front pasting):
SUS304), hairline
Polyester film
115 (W) x 254 (H) x 54.6 (D)mm
—
400g
Wall mounting bracket:
YC-290
Back Box YC-841
Open collector output, withstand
voltage: Max. 30V DC,
control current: Max. 50mA,
one shot: can be set from 1 to
9 sec, screw terminal (polarized)
—
—
IP54 (Note that panel edges
must be sealed at installation.)
—
Panel: Stainless steel
(SUS304), hairline/
Call button: Metal
115 (W) x 162 (H) x
54 (D)mm
850g
680g
Flush-mount: 3-gang electrical
Flush-mount: Back Box ,
YC-241
box or Back Box YC-150
Wall surface-mount:
Wall surface-mount:
Wall mount Box YC-251 Wall mount Box YS-13A
*0dB = 1V
Hands-Free
Master Station
Board Unit
N-8031SB
Power Source
Power Consumption
Wiring Method
Speech Method
Hands-Free
Substation
Board Unit
IP Network Intercom Exchanges
N-8050SB
48V DC (supplied from the IP network intercom exchange (option))
1.8W (rated), 2.4W (max.)
1 set of twisted pair cables
Hands-free conversation
Hands-free conversation
(Handset conversation can
be established in conjunction
with the RS-191(option))
Audio Frequency Range
300 – 7,000Hz
Transmission Range
Max. 1500m (ø0.65mm. Loop resistance 170)
Dial Input
Solderless connector
(10 pins, male),
—
open voltage: 3.3V DC,
short-circuit current: 1mA
External Dial Input
No-voltage make contact
input, open voltage: 5V DC,
—
short-circuit current: 1mA,
screwless connector (5 pins)
Contact Output
Open collector output, withstand
voltage: Max. 30V DC,
—
control current: Max. 50mA, one
shot: can be set from1 to 9 sec,
screw terminal (polarized)
Dimensions
70 (W) x 185 (H) x 20.6 (D)mm 67 (W) x 128.3 (H) x 26 (D)mm
Weight
205g (including accessories)
100g (including accessories)
Option
Handset: RS-191
N-8000EX
Power Source
Power Consumption
Interface Section or Station
Speech Link
Line Capacity
Wiring Method
Transmission Range
Paging Output
Network Section
Network I/F
Network Protocol
Audio Packet
Transmission System
Audio Packet Omission
Audio Delay Time
Finish
Dimensions
Weight
N-8010EX
220 – 240V AC, 50/60Hz
50W (at rated), 75W (max.)
Internal: 4/External: 8
Internal: 1/External: 2
Up to 16 stations
1 set of twisted pair cables
Max. 1500m (ø0.65mm. Loop resistance 170)
Audio: 2 channels Max. 0dB*, 600,
Station paging only
balanced, detachable terminal block
Control: 2 channels, no-voltage
make contact output (24V DC/0.5A),
removable terminal block
10BASE-T/100BASE-TX (Automatic-Negotiation)
TCP/IP, UDP, ARP, ICMP, HTTP, RTP, IGMP
Unicast, Multicast
Silence insertion
80ms, 320ms (Controllable on the software)
Pre-coated steel plate, black, 30% gloss
420 (W) x 44.3 (H) x 356 (D)mm
4.1kg
4.2kg
*0dB = 1V
*0dB = 1V
12
2-Core
Shielded
Cable Type
Sub-station Interface Unit
N-8000RS
Power Source
Power Consumption
Interface Section for Sub-station
Number of Lines
Number of Speech Link
Transmission Range
Wiring Method
Network Section
Network I/F
Network Protocol
Audio Packet Transmission System
Voice Packet Loss Recovery
Audio Delay Time
Finish
Dimensions
Weight
Options
40W(at rated), 50W(max.)
16 lines
1 link
500m/ø0.5mm, 800m/ø0.65mm, 1300m/ø0.9mm
Two-core shielded cable
10BASE-T/100BASE-TX (Automatic-Negotiation)
TCP/IP, UDP, ARP, ICMP, HTTP, RTP, IGMP
Unicast, Multcast
Silence insertion
80ms, 320ms (Controllable on the software)
Pre-coated steel plate, black, 30% gloss
420 (W) x 44.3 (H) x 325.5 (D)mm
3.9kg
3.8kg
Wall mounting bracket: YC-850
Sub-station
(Outdoor Vandal-Resistant Type)
RS-180
Finish
Dimensions
Weight
Options
Open collector output: 24V DC, 30mA
(The open collector output is kept turned on till
the conversation is finished after the call button
was pressed.)
Panel: Stainless steel (SUS304), hairline
Call Button: Metal, red
Printed Circuit Board: Weather-resistant coating
120 (W) x 120 (H) x 58.5 (D)mm
570g
2-gang electrical box: YC-302,
Indoor wall-mount box: YC-822,
Outdor wall-mount box: YC-823
IP Intercom
Switch Panel
RS-141
Dimensions
Weight
Options
13
Momentary (EMERGENCY, NORMAL)
—
Panel: Stainless steel, hairline
Call-in Switch: Resin, red
Privacy Switch (normal): Resin, white
Sub-station
(Indoor Vandal-Resistant Type)
Sub-station
(Indoor Type)
RS-170
RS-160
RS-150
—
—
—
Panel: Stainless steel (SUS304), hairline
Call Button: Resin, black
Panel: Stainless steel (SUS304), hairline
Call Button: Metal
120 (W) x 120 (H) x 57.5 (D)mm
120 (W) x 120 (H) x 48.5 (D)mm
540g
410g
2-gang electrical box: YC-302,
2-gang electrical box: YC-302, Indoor wall-mount box: YC-822
Indoor wall-mount box: YC-822,
Outdor wall-mount box: YC-823
IP Intercom
Switch Panel
RS-144
Call-in Switch
Privacy Switch
Wiring
Finish
32W (at rated), 38W (max.)
2 links
Sub-station
(Emergency Use)
Control Output
N-8010RS
220 – 240V AC, 50/60Hz
IP Intercom
Switch Board
Switch Panel
RS-141
RS-141
RS-143
RS-140
Momentary
Latching
Two-core shielded cable
Panel: Stainless steel, hairline
Call-in Switch: Resin, red
Panel: Stainless steel, hairline
Call-in Switch: Resin, red
Privacy Switch (normal): Resin, white
70 (W) x 115 (H) x 28.6 (D)mm
80g
Flush-mount box: YC-801, Wall-mount box: YC-802, Handset: RS-141
RS-142
Call Switch Wiring
Wiring
Weight
4 cables (for 2 momentary switches)
Two-core shielded cable
30g
4-Wire
Type
Sub-station Interface Unit
Analog Standard
Master Station
N-8400RS
Power Source
Power Consumption
Interface Section for Sub-station
Number of Lines
Number of Speech Link
Transmission Range
Wiring Method
Network Section
Network I/F
Network Protocol
Audio Packet
Transmission System
Voice Packet Loss Recovery
Audio Delay Time
Finish
Dimensions
Weight
Option
N-8410MS
220 – 240V AC, 50/60Hz
35W (at rated), 50W(max.)
16 lines
2 links
1km)/ø0.5mm, 1.5km/ø0.65mm, 2km/ø0.9mm
2 sets of twisted pair cables
10BASE-T/100BASE-TX (Automatic-Negotiation)
TCP/IP, UDP, ARP, ICMP, HTTP, RTP, IGMP
Unicast, Multcast
Silence insertion
80ms, 320ms (Controllable on the software)
Pre-coated steel plate, black, 30% gloss
420 (W) x 44.3 (H) x 325.5 (D)mm
4kg
Wall mounting bracket: YC-850
Sub-station
(Emergency Use)
Power Source
24V DC (supplied from the sub station interface unit N-8400RS)
Current Consumption
Max. 30mA
Wiring Method
2 set of twisted pair cable
Speech Method
Hands-free or handset conversation
Audio Frequency Range
300 Hz – 7k Hz
Transmission Range
1km/ø0.5mm (AWG24),1.5km/ø0.65mm (AWG22),
2km/ø0.9mm (AWG19)
Finish
Body, Handset: ABS resin, gray
Dimensions
148 (W) x 208 (H) x 70.5 (D)mm (excluding a curl cord section)
Weight
720g
Option
Wall mounting bracket: YC-280
*0dB = 1V
Sub-station
Sub-station
(Outdoor Vandal-Resistant Type) (Indoor Vandal-Resistant Type)
Sub-station
(Indoor Type)
RS-481
RS-480
Call-in Switch
Control Output
Wiring
Dust/Water Protection
Finish
Dimensions
Weight
Options
Open collector output: 30V DC, 30mA
IP54
Panel: Stainless steel, hairline
Call Switch: Metal, red
Circuit board: Weather-resistant coating
120 (W) x 120 (H) x 50.5 (D)mm
575g
2-gang electrical box: YC-302, Handset: RS-481
Indoor wall-mount box: YC-822,
Outdor wall-mount box: YC-823
RS-470
RS-460
—
Panel: Stainless steel, hairline
Call Switch: Metal, silver
Panel: Stainless steel, hairline
Call Switch: Resin, black
120 (W) x 120 (H) x 49.5 (D)mm
120 (W) x 120 (H) x 41.5 (D)mm
550g
540g
510g
2-gang electrical box: YC-302,
2-gang electrical box: YC-302, Indoor wall-mount box: YC-822
Indoor wall-mount box: YC-822,
Outdor wall-mount box: YC-823
Telephone Interface Unit
C/O Interface Unit
N-8000AL
Power Source
Power Consumption
Line: Public Switched telephone networks
Number of Lines
Contact Signal Type
Selective Signal Type
Signal System
Monitor Function
Control Function
Wiring Method
Network Section
Network I/F
Network Protocol
Audio Packet Transmission System
Finish
Dimensions
Weight
Options
RS-450
Momentary (Emergency call: Press twice within 400 ms)
—
Twisted pair cables (2-pair)
N-8000CO
220 – 240V AC, 50/60Hz
8W (Max.)
7W (Max.)
1 line
DTMF Signal
—
—
Line Loop detection
Caller ID function
—
DTMF Signal
Compatible with loop start signalling
—
—
1 pair of twisted pair cable
10BASE-T/100BASE-TX (Automatic-Negotiation)
TCP/IP, UDP, ARP, ICMP, HTTP, RTP, IGMP
Unicast, Multicast
Pre-coated steel plate, black, 30% gloss
210 (W) x 44.3 (H) x 267 (D)mm
1.7kg
Rack mounting bracket: MB-15B-BK, MB-15B-J
Wall mounting bracket: YC-850
* 0dB = 1V
14
YC-850 Wall-Mount Bracket
YC-280 Wall-Mount Bracket
YC-290 Wall-Mount Bracket
YC-251 Surface-Mount Back Box
Designed to mount N-8000RS, N-8010RS,
N-8400RS, N-8000DI, N-8000AF, N-8000AL
and N-8000CO on a wall.
Finish: Surface-treated steel plate, black, 30% gloss
Dimensions: 45.1 (W) x 220 (H) x 10 (D)mm
Designed to mount N-8011MS on a wall.
Finish: Surface-treated steel plate, gray, paint
Dimensions: 64 (W) x 131.5 (H) x 31.8 (D) mm
Designed to mount N-8000MS, N-8010MS,
N-8020MS, N-8410MS, N-8510MS and
N-8600MS on a wall.
Finish: Surface-treated steel plate, gray, paint
Dimensions: 100 (W) x 140 (H) x 31.8(D) mm
Designed to mount N-8031MS on a wall.
Finish: Surface-treated steel plate, white
Dimensions: 124 (W) x 258.5 (H) x 50.5 (D) mm
YC-241 Flush-Mount Back Box
YC-150 Flush-Mount Back Box
YC-801 Flush-Mount Box
YS-13A Surface-Mount Back Box
Designed to surface-mount N-8050DS and
N-8640DS on a wall.
Finish: Zinc-plating
Dimensions: 163.5 (W) x 114.5 (H) x 55 (D) mm
Designed to surface-mount N-8031MS on a wall.
Finish: Colored chrome painting
Dimensions: 276 (W) x 119 (H) x 67 (D) mm
Designed to flush-mount RS-140, RS-143 and
RS-144 on a wall.
Finish: Colored chrome painting
Dimensions: 72 (W) x 119 (H) x 57 (D) mm
YC-802 Wall-Mount Box
Designed to flush-mount RS-140, RS-143 and
RS-144 on a wall.
Finish: Surface-treated steel plate, white
Dimensions: 75 (W) x 124 (H) x 50.5 (D) mm
YC-841 Back Box
Designed to flush-mount N-8033MS on a wall.
Finish: Surface-treated steel plate, white
Dimensions: 119 (W) x 258 (H) x 57 (D) mm
AD-1210P AC Adapter
The AD-1210P is an AC adapter to
operate the IP Station on AC.
Human Society with
Sound & Communication
Designed to flush-mount N-8050DS and
N-8640DS on a wall.
Finish: Zinc-plating
Dimensions: 184 (W) x 119 (H) x 57 (D) mm
YC-302 2-Gang Electrical Box
Designed to mount RS-150, RS-160, RS-170,
RS-180, RS-450, RS-460, RS-470 and RS-480
on a wall.
Finish: SPHT, MFZn4 (glazed chromate)
Dimensions:
Outlet box: 102( W) x 102 (H) x 44 (D)mm
Cover: 106 (W) x 106 (H) x 13 (D)mm
YC-823 Outdoor Wall-Mount Box
Designed to mount RS-170, RS-180, RS-470
and RS-480 on a wall.
Finish: Stainless plate, off-white
Dimensions: 124 (W) x 124 (H) x 62 (D) mm.
YC-822 Indoor Wall-Mountl Box
Designed to mount RS-150, RS-160, RS-170,
RS-180, RS-450, RS-460, RS-470 and RS-480
on a wall.
Finish: Surface-treated steel plate, white
Dimensions: 124 (W) x 124 (H) x 61 (D) mm
TOA Corporation
www.toa.jp
Specifications are subject to change without notice.
Printed in Japan (1303) 833-52-325-5F u
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising