DCPS Programmable DC Power Supply

DCPS Programmable DC Power Supply
DCPS
Programmable DC Power Supply
CINERGIA’s DC converters are power electronics devices designed
to generate a DC constant voltage, current, power, resistance or IU
battery charge profile. Our DC products (DCPS, EL-DC, B2C) differ
in the possible operation modes.
Thanks to its bidirectional power hardware, the test energy can be
regenerated to the electrical grid.
FUNCTIONAL DESCRIPTION
KEY FEATURES
Operation modes:
-Constant Voltage (CV)
-Constant Current (CC)
-Constant Power (CP)
-Automatic test from csv file
6.75 – 160 kW
Three DC channels in each unit:
The three channels can be controlled independently
allowing different voltage, current or power setpoints.
In standard units the Operation mode will be the same for
the three channels. Optionally, each channel could be
operated in different mode (if interested, please ask for
option Independent Channels Operation).
2Q or 4Q applications:
-In 2Q applications, the EUT will be connected between
one channel and the common negative.
-In 4Q applications, the EUT will be connected between
two channels
2/4 Quadrant Power Supply
Regenerative up to 100%
rated power
1 channel Output:
20 to 750V, 0 to ±555A
3 channels Output:
20 to 750V, 0 to ±185A/ch
Bipolar Output
-350 to +350V, 0 to ±185A
+270V/0/-270V Output
for Avionics applications
CV, CC, CP modes
DCPS_2016_v1
Option for Independent
Channels Operation
CINERGIA
Pintor Roig i Soler, 10
08916, Badalona, BARCELONA
www.cinergia.coop
cinergia@cinergia.coop
T. +34 934 864 358
DCPS
Programmable DC Power Supply
CONCEPTUAL SCHEMATIC
DC Power Supply
AC
DC
GRID
DC
DC
EQUIPMENT
UNDER TEST
(EUT)
Recommended
BACK-TO-BACK TOPOLOGY
The equipment is formed by two IGBT-based power stages: a grid-side Active Rectifier producing
sinusoidal currents with low harmonic distortion and close to unity power factor; and three output DCDC
converters generating three independent DC channels.
Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.
TECHNICAL DIAGRAM
AC IN (GRID side)
DC OUT (EUT side)
3P+ N
3 CH-COM
Current
sensor x 3
Voltage
sensor x 3
Drivers x
DSP
6
EMC
filter
-U
-U
EMC
filter
Voltage
sensor x 2
CAN
control
Drivers x
6
DSP
control
Current
sensor x 3
Voltage
sensor x 3
HMI
MODBUS/TCP
ETHERNET
DCPS_2016_v1
AC Input is connected to the grid (isolation transformer with neutral is recommended)
DC Output is connected to the Equipment Under Test (EUT) and can be used as:
- Independent channels mode: three 2Q channels with a common negative
- Parallel channels mode: one 2Q channel (3 times rated current per phase)
- One 4Q bipolar channel (connecting the load between two channels)
- One +270/0/-270V channels for avionics applications
www.cinergia.coop
CH1
CH2
CH3
Com_neg
DCPS
Programmable DC Power Supply
USER INTERFACE
SOFTWARE FEATURES
Local 3.2” Touchscreen panel
Windows 7/10 user interface for remote operation
and data acquisition.
Remote Control port:
LAN Ethernet with Modbus/TCP protocol.
Digital IO port:
-4 digital inputs
-3 relay outputs
-1 Emergency stop
Optional analog port:
-1 analog input 0-10V
-3 analog outputs 0-10V
Optional communications:
RS485, RS232, CAN, LabView
OPERATION AREA: UNIPOLAR
OPERATION AREA: BIPOLAR
800.0
400.0
700.0
300.0
200.0
Parallel channels
mode
500.0
400.0
Minimum voltage
at rated power
Independent
channels mode
300.0
Output voltage (V)
Output voltage (V)
600.0
100.0
-Bipolar
0.0
+Bipolar
-100.0
200.0
-200.0
100.0
-300.0
Minimum
output voltage
0.0
Output current (A)
In UNIPOLAR the equipment under test is connected between a
channel and the common negative. Two possible configurations:
DCPS_2016_v1
Independent channels: CH1, CH2 and CH3 are available and can
be parametrized with different voltage, current or power
setpoint.
-400.0
Output current (A)
In BIPOLAR the equipment under test is connected between
channels CH1, CH2 and CH3. The common negative is not
connected and CH2 is used as 0V reference for CH1 and CH3.
This connection will be used to create +270V/0/-270V avionics
DC bus system.
Parallelized channels: the three channels are “shortcircuited”
internally to provide three times the current.
Maximum voltage in bipolar connection is ±350V. Ask for further
information if ±750V are needed.
Cooling
The power supply is air-cooled internally.
Options
Galvanic Isolation (recommended)
Isolation monitor
Independent Channels Operation
Analog Input/Output Port
RS485, RS232, CAN
Labview drivers
Mechanical housing
The power supplies are housed in compact cabinets
with wheels up to 120kVA for easier transportation.
www.cinergia.coop
DCPS
Programmable DC Power Supply
RANGE AND SPECIFICATIONS
MAGNITUDE
Power
Input side (GRID side)
AC Voltage
Voltage range
Rated AC Current
Frequency
THDi
Power Factor
Efficiency
Overload
Output side (EUT side)
DC Voltage
Minimum voltage
DC Current
DC Overcurrent
Operation Modes
Constant Voltage
Constant Current
Constant Power
Response time
General
Measurements
User interface
VALUE
(grid side)
7.5kVA-200kVA
Rated
3x400Vrms+Neutral+Earth
+15% / -20 %
10-290Arms per phase
48-62Hz
<3%
≥0.99
0-1 (capacitive/inductive)
>92%
125% for 10 min / 150% for 60 s
Depends on model (see table)
(at rated power)
Typical at rated power
Configurable by user
(at rated power)
Channel-Com_neg
Channel-Com_neg
Channel-Channel
at rated power1
Parallel channels mode
Independent channels mode
Bipolar output
Range2
0-100%
0-±100%
0-±100%
Rated resistance load
20 to 750V (≤60kVA)
40 to 750V (>60kVA)
-350 to 350V
320V
0 to ±555A global
0 to ±185A per channel
0 to ±185A per channel
110% during 1 min
Resolution3
Ripple3
<±0.1%
<1%
<±0.1%
<1%
<±0.1%
<1%
1-5ms (10-90%)
Input Voltage (Vrms) and Current (Irms)
Input and Output Power
Output Voltage and Current
Temperatures
3.2” Touchscreen
Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO)
Communication Port: Ethernet (Optionals: RS485, RS232, CAN)
Communication Protocol: Modbus/TCP
10-90% (Absolute maximum, without condensation)
5-35 ºC (Absolute maximum)
Forced air
Over Current, Over Voltage, Shortcircuit, Overtemperature
DCPS_2016_v1
Humidity
Temperature
Cooling
Protections
Standards
CE Marking
Safety
EN-62040-1-2, EN-60950-1
EMC
EMC: EN-62040-2
1 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail
2 Range is related to rated values of each model as defined in table MODELS
3 Resolution and ripple are related to the FS of each model. Contact us for further information.
All specifications are subject to change without notice.
www.cinergia.coop
DCPS
Programmable DC Power Supply
MODELS
REFERENCE
RATED
kVA
kW
DCPS7.5
DCPS10
DCPS15
DCPS20
DCPS30
DCPS40
DCPS50
DCPS60
DCPS80
DCPS100
DCPS120
DCPS160
DCPS200
7.5
10
15
20
30
40
50
60
80
100
120
160
200
6.75
9
13.5
18
27
36
45
54
72
90
108
128
160
RATED CURRENT
Independent Parallel
0-750v
0-750v
±30A
±10A
±45A
±15A
±60A
±20A
±75A
±25A
±90A
±30A
±115A
±38A
±140A
±47A
±180A
±57A
±315A
±105A
±390A
±130A
±390A
±130A
±465A
±155A
±185A
±555A
Bipolar
-350 to 350V
±10A
±15A
±20A
±25A
±30A
±38A
±47A
±57A
±105A
±130A
±130A
±155A
±185A
All specifications are subject to change without notice.
GALVANIC ISOLATION (recommended)
REFERENCE
RECOMMENDED
CIRCUIT BREAKER
WEIGHT
kg
DIMENSIONS
DxWxH (mm)
IT7.5
IT10
IT15
IT20
IT30
IT40
IT50
IT60
IT80
IT100
IT120
IT160
IT200
Type C - 25A
Type C - 25A
Type C - 32A
Type C - 40A
Type D - 80A
Type D - 100A
Type D - 125A
Type D - 160A
Type D - 200A
Type D - 250A
Type D - 315A
Type D - 400A
Type D - 500A
145
145
145
145
174
217
280
381
435
458
514
612
753
Inside the
cabinet
(*) The transformer is delivered in a stand-alone cabinet IP23
DCPS_2016_v1
All specifications are subject to change without notice.
www.cinergia.coop
595x415x708 (*)
789x490x865 (*)
964x684x1252 (*)
1192x744x1430 (*)
WEIGHT
kg
150
150
150
150
150
185
185
185
265
290
290
540
550
DIMENSIONS
DxWxH (mm)
770x450x1100
880x590x1320
850x900x2000