8IR103 PIR MOTION DETECTOR With PET IMMUNITY up to 25Kg

8IR103 PIR MOTION DETECTOR With PET IMMUNITY up to 25Kg
PRODUCT DESCRIPTION
The Activ8 PIR detector uses a special
designed optical Lens with unique Quad
(Four element) PIR Sensor and new ASIC
based electronics optimized to eliminate false
8IR103
alarms, caused by small animals and Pets.
PIR MOTION DETECTOR
The Activ8 PIR provides unprecedented
With PET IMMUNITY up to 25Kg
levels of immunity against visible light.
The Detector offers an exceptional level of
INSTALLATION INSTRUCTIONS
detection capability and stability for every
security installation.
lens.
The Activ8 PIR provides Pet immunity up
to 25Kg (55 lbs). For better immunity
avoid installation in areas where pets can
reach upwards.
DETECTION PATTERN
TYPICAL INSTALLATION
The Activ8 PIR is supplied with Wide Angle
English
P/N 7101507 REV. B A.Y.
Activ8 PIR FEATURES
SELECT MOUNTING LOCATION
FEATURES
Choose a location most likely to intercept an
intruder. See detection pattern. The Quad high
quality sensor detects motion crossing the beam;
it is less sensitive detecting motion towards the
detector.
The Activ8 PIR performs best when provided
with a constant and stable environment.
Quad Linear Imaging Technology for
sharp analysis of body dimensions and
differentiation from background and
animals.
New ASIC based electronics.
Immunity to animals up to 25kg (55 lbs).
18m Detection Range with Wide Angle
Lens.
Temperature compensation.
Compact Design for Residential
Installation.
Variable pulse width adjustment.
Sensitivity adjustment.
Environmental immunity.
Height installation calibration
free (1.8m – 2.4m).
LED Remote function.
AVOID THE FOLLOWING LOCATIONS
Facing direct sunlight.
Facing areas subject to rapid
temperature changes.
Areas with air ducts or substantial air
flows.
REMOVAL OF FRONT COVER
MOUNTING THE DETECTOR
1. To remove the front cover, unscrew the holding
screw and gently raise the front cover.
KNOCKOUT HOLES
2. To remove the PC board, carefully unscrew the
holding screw located on the PC board.
A
A
3. Break out the desired holes for proper
installation.
4. The circular and rectangular indentations at the
bottom base are the knockout holes for wire
entry. You may also use mounting holes that
are not in use for running the wiring into the
detector.(For option with bracket - lead wire
through the bracket)
5. Mount the detector base to the wall, corner or
ceiling. (For option with bracket install bracket).
6. Reinstall the PC board by fully tightening the
holding screw. Connect wire to terminal block.
A
D
CB
C
B
7. Replace the cover by inserting it back in the
appropriate closing pins and screw in the holding
screw.
Unscrew the holding
screw and open base
DETECTOR INSTALLATION
PCB LAYOUT
TERMINAL BLOCK CONNECTIONS
Terminals 4 & 5 - Marked RELAY
These are the output relay contacts of the
detector. Connect to a normally closed zone in
the control panel.
Terminals 1 & 6 - Marked EOL
option.
End of line
Terminals 2 & 3 - Marked TAMPER
If a Tamper function is required connect these
terminals to a 24-hour normally closed protective
zone in the control unit. If the front cover of the
detector is opened, an immediate alarm signal will
be sent to the control unit.
Terminal 7 - Marked + (+12V)
Connect to a positive Voltage output of 8.2 16Vdc source (usually from the alarm control
unit)
Terminal 8 - Marked - (GND)
Connect to the negative Voltage output or ground
of the control panel.
A. Wire access
holes
B. Use for flat
wall
mounting
BC
C. Corner
mounting use all 4
holes. Sharp
left or right
C
angle
mounting use 2 holes
B
(top and
bottom)
D. For bracket
mounting
SETTING-UP THE DETECTOR
PULSE WIDTH JUMPER SETTING
LED ENABLE JUMPER SETTING
Very stable environment
Jumper #1 = ON
Without PET
LED ON
Moderate nuisance situation
Jumper #2 = ON
PET up to 15 kg (33.1 lb)
LED OFF
PIR SENSITIVITY ADJUSTMENT
POTENTIOMETER adjustment according to
protected area range.
Use the potentiometer to adjust the detection
range between 68% and 100% (factory set to
84%). Rotate the potentiometer clockwise to
increase range, counter-clockwise to decrease
range.
WIRE SIZE REQUIREMENTS
PET IMMUNITY JUMPER SETTING
Immunity to an
animal up to 15 kg
Relatively high chance of false
alarms
Jumper #3 = ON
PET up to 25 kg (55 lb)
Wire Length
m 200 300
Wire Diameter mm .5 .75
Wire Length
ft. 800 1200
Wire Gauge
# 22 20
Immunity to an
animal up to 25 kg
TESTING
Use #22 AWG (0.5 mm) or wires with a larger
diameter. Use the following table to determine
required wire gauge (diameter) and length of
wire between the detector and the control panel.
400
1.0
2000
18
800
1.5
3400
16
BRACKET INSTALLATION OPTION
TEST PROCEDURES
WAIT FOR ONE MINUTE OF WARM UP TIME
AFTER APPLYING 12 VDC POWER.
CONDUCT TESTING WITH THE PROTECTED
AREA CLEARED OF ALL PEOPLE.
Walk test
1. Remove front cover.
The pulse jumper must be in position 1. The
LED must be enabled.
2. Replace the front cover.
3. Start walking slowly across the detection zone.
4. Observe that the detector s LED lights
whenever motion is detected.
5. Allow 5 sec. between each test for the detector
to stabilize.
6. After the walk test is completed, the LED may
be disabled.
NOTE:
Walk tests should be conducted, at least once a
year, to confirm proper operation and coverage of
the detector.
WALL AND CEILING INSTALLATION OPTIONS
REPLACING THE LENS
1. Remove the front cover.
2. Using a small flat screwdriver, press on left
and right snaps of the lens and pull the lens
out from its place (front cover side).
3. Replace a new lens.
4. Push the lens to its place by pressing again
from outside of the front cover until a click is
heard.
5. Replace front cover.
TECHNICAL SPECIFICATION
MODEL
Detection Method
Power Input
Current Draw
Temperature
Compensation
Pulse Width
Alarm Period
Alarm Output
Tamper Switch
removed
Warm Up Period
LED Indicator
Operating Temperature
RFI Protection
EMI Protection
Dimensions
Weight
Activ8 PIR
Quad (Four element) PIR
7.8 to 16 VDC
Standby: 8mA (± 5%)
Active: 10mA (± 5%)
YES
Adjustable
2 sec (± 0.5sec)
N.C 28VDC 0.1 A with 27Ohm series protection resistor
N.C 28VDC 0.1A with
10 Ohm series protection resistor - open when cover
is
60sec (± 5sec)
LED is ON during alarm
-20 C to +60 C
(-4 F to +140 F)
30V/m 10 - 1000MHz
50,000V of electrical interference from lightning or power through
90mm x 59mm x 37mm
(3.54 x 2.32 x 1.46 )
40gr (1.4oz)
Honeywell Security & Communications
(UK64)Newhouse Industrial Estate
Motherwell
Lanarkshire
ML1 5SB
Tel +44 (0)1698 738200
Fax +44 (0)1698 738300
Tech Support: +44 (0)844 8000 235
www.honeywell.com/security/uk/intruder
.