IN574-95
INFORMATION
Cylinder
Speed Checker (Built-in Magnet Cylinder)
RoHS
Speed (mm/s)
3
measurement Time required for stroke (s)
modes
Operation count (Times)
Realizes increase in efficiency with
visualization of air cylinder operation.
 Quantification of cycle time improvements
 For reduction of numerical management/adjustment labor when starting up equipment
 For reduction of numerical confirmation/inspection labor during periodic maintenance
Caution
Example of cycle time
measurement
T
he measurement may not be performed with an air gripper or rotary actuator, or the measurement
deviation may increase. Please contact SMC for more information.
IN574-95/-73
14-E641 B
IN574-95/-73
M 3 Measurement Modes
Speed (mm/s)
Measures the speed of cylinders.
Sensor head
Reverse direction
(Rod retraction end)
Rated measurement range
Note)
Positive
direction
–1999 to 1999 mm/s
Note) Minus (-) is added to the measured value to distinguish the extension and retraction of a cylinder.
Rod extension end: Positive direction
Rod retraction end: Reverse direction (–)
Red
(Rod extension
end)
Green
Stroke direction to be measured
∗ Although a measurement
can be done even when the
sensor is mounted in the
reverse direction, the display
direction is also reversed.
Display part
Cylinder
Time required for stroke (s)
Measures the time required for the stroke of the cylinder (rod retraction end to rod extension end).
Timing chart (When rod extends)
Rod retraction end
Rated measurement range
Rod extension end
Field wireable
connector
(Refer to page 2.)
Note)
−999.9 to 999.9 s
Note) Minus (-) is added to the measured value to distinguish the extension and retraction of a cylinder.
Rod extension end: Positive direction
Rod retraction end: Reverse direction (–)
Measurement
timing
Time required for stroke
Measurement start
Operation count (Times)
Time
Y connector
(Refer to page 2.)
Auto switch
(Refer to
page 2.)
Measurement end
Display
part
Timing chart
Measures the operation count of a cylinder for 1 minute.
Cylinder
Rated measurement range
0 to 999 times
Count
timing
Measurement start
Increase Count (1 time) Increase Count (2 times)
M Compact: 40 (Width) x 110 (Height) x 20 (Depth) mm
M Lightweight: Approx. 65 g (Body)/25 g (Sensor)
∗ Excluding dry cell batteries.
M Battery powered: 2A dry cell battery x 2,
continuous use for 15 hours or more.
1
M With backlight
M With auto power-off function∗
∗ If a button is not operated for 15 min. or more,
the power supply will turn off automatically.
Cylinder Speed Checker
RoHS
IN574-95/-73
How to Order
Sensor head + Display part
Sensor head
IN574-95
IN574-73
Display
part
Sensor head
Speed Measurement Type
Model
IN574-95
q Sensor head
(q Sensor head + w Display part)
w Display part
q Sensor head w Display part
Application example
Time Required for Stroke/Operation Count Measurement Type
+
w Display part
e Auto switch
with pre-wired
connector
or
r Auto switch
with lead
wire entry
Order separately when using the time required for stroke/operation count measurement modes.
Application example
t Y connector
e Auto switch
with pre-wired
connector
w Display
part
e Auto switch with pre-wired connector
D M9N S A PC
Applicable auto switch
∗ The sensor head is not used when the
checker is used for the time required for
stroke/operation count measurement.
Application example
t Y connector
Function Electrical entry Applicable model
Grommet (In-line)
M9N
—
Grommet (Perpendicular)
M9NV
M9NW
2-color Grommet (In-line)
indication Grommet (Perpendicular) M9NWV
M9NA
Water Grommet (In-line)
resistant Grommet (Perpendicular) M9NAV
Ordering example
· IN574-95 1 pc.
Cylinder Speed Checker (Sensor head + Display part)∗
· D-M9NSAPC 2 pcs.
Auto switch with pre-wired connector
· PCA-1557798 1 pc.
Y connector
Connector model
A M8-3 pin
D M12-4 pin
y Field wireable
connector
r Auto switch
with lead wire
entry
Lead wire length
S 0.5 m
M 1.0 m
w Display
part
∗ Please contact SMC for other applicable
auto switches.
r Auto switch with lead wire entry
t Y connector
D M9N
M8
M12
Ordering example
1 pc.
· IN574-95 Cylinder Speed Checker (Sensor head + Display part)∗
· D-M9N 2 pcs.
Auto switch with lead wire entry
· PCA-1557730 2 pcs.
Field wireable connector
· PCA-1557798 1 pc.
Y connector
∗ The sensor head is not used when the
checker is used for the time required for
stroke/operation count measurement.
PCA-1557798
y Field wireable connector
Applicable auto switch
Function Electrical entry Applicable model
Grommet (In-line)
M9N
—
Grommet (Perpendicular)
M9NV
M9NW
2-color Grommet (In-line)
indication Grommet (Perpendicular) M9NWV
M9NA
Water Grommet (In-line)
resistant Grommet (Perpendicular) M9NAV
M8
M8
Lead wire length
0.5 m
Nil
1.0 m
M
∗ Please contact SMC for other applicable
auto switches.
∗ The lead wire is converted to M8/M12 connector for use.
M12
M12
PCA-1557785
PCA-1557730
M8
Two auto switches
with M8 connectors
can be connected.
M12∗
PCA-1557743
Two auto switches
with M12 connectors
can be connected.
M12
M12
Attached to end of
the lead wire of the
auto switch. Used
in combination with
PCA-1557798.
Attached to end of
the lead wire of the
auto switch. Used
in combination with
PCA-1557785.
∗ Note that although it can be connected,
the IP65/67 may not be held depending
on the assembly method.
Refer to the WEB catalog for the details on the auto switches (e, r) and the M8/M12 connectors (t, y).
2
IN574-95/-73
Specifications Note 1)
Environmental
resistance
Model
IN574-95
Measurement mode
Speed
Time required for stroke
Operation count (Times)
Rated measurement range –1999 to 1999 mm/s
–999.9 to 999.9 s
0 to 999 times
Minimum
0.01 s (0.00 to 99.99 s, 0.00 to –99.99 s)
1 mm/s
1 time
display unit
0.1 s (100.0 to 999.9 s, –100.0 to –999.9 s)
Measurement accuracy
—
±20% or less
±0.2 s or less
2 x 1.5 VDC 2A alkali dry cell batteries
Note
2)
Power supply
(continuous use for 15 hours or more)
Applicable cylinder
Built-in magnet
Enclosure
IP40
Operating
Operating: 0 to 40°C, Stored: –10 to 60°C
temperature range
(with no freezing or condensation)
Operating
Operating/Stored: 35 to 85% R.H.
humidity range
(with no condensation)
Vibration
10 to 150 Hz at 1.5 mm amplitude or 98 m/s2 acceleration whichever is smaller,
resistance
in X, Y, Z directions for 2 hrs. each (De-energized)
Impact resistance
100 m/s2 in X, Y, Z directions 3 times each (De-energized)
Weight
Sensor part: 25 g, Body: 65 g (excluding dry cell batteries)
Standards
RoHS, CE
Speed Measurement Sensor/D-F8N
Power supply voltage
4.5 to 28 VDC
Current consumption
10 mA or less
Load voltage
28 VDC or less
Load current
40 mA or less
Internal voltage drop 1.5 V or less (0.8 V or less at 10 mA)
Leak current
100 µA or less
Operating time
1 ms or less
Indicator light Red LED is illuminated when turned ON.
Ambient temperature
–10 to 60°C
Applicable Auto Switches for the
Time Required for Stroke/
Operation Count Measurement
Power supply voltage
Output type
ON voltage
OFF current
14 VDC or less
NPN open collector
2 V or less
100 µA or less
Note 1) The above specifications may change depending on the operating environment.
Note 2) 2A alkali dry cell batteries are not included, and must be acquired separately.
Dimensions
20
IN574-95 (Sensor head + Display part)
D-F8N (2 pcs.)
230
Red tape
110
20
40
500
Green tape
M12 Connector
Tube (3 places)
Sensor head
Wiring
Terminal no.
1
Description
+15 V
Note
—
2
Output signal 1
D-F8N
3
GND
—
4
Output signal 2
D-F8N
2
1
3
4
Plug connector
A-coded (Normal key)
5
1
2
4
3
Socket connector
A-coded (Normal key)
Display part
Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.