LV EL N - Gexpro

LV EL N - Gexpro
Catalog Number
Notes
Type
FEATURES
INTENDED USE
All-Conditions Exits
Suitable for cold weather (down to -40 oC with CW option), wet location,
security/prisons and high-abuse applications.
CONSTRUCTION
LV EL N
Durable cast-aluminum construction – rugged housing walls are .250 to
.525" thick.
NEMA 4X option is available for wet and hose-down applications.
NEMA 4X Rating Available
LED LAMPS EMERGENCY
Clear, UV-stable polycarbonate cover is .130" thick to prevent cracking or
breaking. Cover is secured with four stainless steel Torx T20, tamperproof
screws with center pin.
Polycarbonate faceplate incorporates universal directional chevron
knockouts that are concealed and easily removed and replaced.
Universal mount (UM) option available – top, back, end mounting or
conduit entry. (canopy provided)
Letters 6" high with 3/4" stroke. U.S. Patent No. 5,611,163 and D383,501.
LAMPS
Lamp is constructed using new LED technology. Provides perfectly
uniform illumination.
LED life exceeds 25 years, based on continuous operation. Single-face
exit uses one LED lamp; double-face exit uses two LED lamps. Low energy
consumption — red lamp consumes 3.3 watts (120V) [6.7 watts (120V) with
CSA option]; green lamp consumes 1.7 watts (120V).
BATTERY
Sealed, maintenance-free nickel-cadmium battery delivers 90 minutes
capacity to lamp (30 minutes with CSA option). Constant-current series
charger, automatic recharge after battery discharge.
Vandal-resistant magnetic test switch (magnet included) and LED
indicator mounted on bottom of housing provide a safe, easy means for
testing. Manual test switch also provided inside housing.
Polarized battery connector simplifies installation and maintenance;
prevents charger damage from improper connection.
Brownout protection.
Low voltage disconnect allows battery connection before AC power is
applied and prevents battery damage from deep discharge.
Self-diagnostics (optional). Automatically tests once a month for five
minutes and once every six months for 30 minutes. Bi-color LED status
indicator, test and service required.
Universal and back (no canopy) mount available.
Conduit entry (1/2" - 14 UNC) included with universal mounting.
Cast-aluminum canopy attaches to 10-gauge steel mounting plate for top
or end mounting (not required for back mounting).
Canopy mounting bracket provides 160 lbs. of mounting strength when
mounted to suitable structure. Bracket will only fit a 2-gang junction box.
LISTINGS
UL Listed (standard). CSA Certified or NOM Certified (see Options). 4X option
is UL listed to NEMA 4X ratings. Meets UL 924, NFPA 101 (current Life Safety
Code), CSA C-860 and C22.2 No. 141 (see Options), NEC and OSHA
illumination standards, and State of Minnesota energy-efficient legislation
requiring less than 20W consumption.
WARRANTY
Five-year total customer satisfaction warranty on exit, including lamp.
For shortest lead times, configure product using standard options (shown in bold).
Example: LV S W 1 R 120/277 EL N
ORDERING INFORMATION
LV
®
EL N
S
Family
Face type
LV
S Stencil
Letter
color
R Red
G Green 1
Faceplate/housing
color
(blank) Black faceplate
on black housing
Number of faces
Input
voltage
120/277 Dual
voltage1
120 120V 3
347 347V 3
1 Single-face
2 Doubleface 2
W White on white
WB White on black
BW Black on white
AB Aluminum on
black 1
AW Aluminum on
white 1
NOTES:
1 Not available with CSA option.
2 Available with universal mount only.
3 Only available with CSA option.
4 Back mount standard with single face unless
UM is specified. Not available on double face.
5 Choice of F or FI. Not available with both.
6 Not Energy Star qualified.
Emergency and Special Environments
Emergency
operation
EL N
Options
Nickelcadmium
battery
Mounting
(blank) Back
mount4
UM Universal
mount
(blank) None
F Flashing emergency
operation (45 flashes/min)1,5
FI Fire alarm flashing interface1,5
DL UL listed for damp locations
4X UL listed for NEMA 4X1
CW Cold temperature and NEMA
4X wet location battery pack
(down to -40oC)1,6
SD Self-diagnostics 1
CSA CSA Certified
NOM NOM Certified
Accessories
Order as separate item.
ELA TPS T20
Torx tamperproof bit for T20 center-pin screw
Sheet #: LV-EL-N_SE
HLEX - 110
LV EL N Emergency LED, Extreme
SPECIFICATIONS
MOUNTING
ELECTRICAL
Primary Circuit
All dimensions are in inches (millimeters).
Shipping weight: 12 lbs. (5.45 kgs.).
Lamp
type
Rated
LED life1
Supply
voltage
Red
25+ years
120
Red
Green
Green
25+ years
277
25+ years
120
25+ years
277
Red w/ 25+ years
CSA option
120
Red w/ 25+ years
CSA option
347
Number Input
of lamps2 watts
1
3.3
End Mount
Max. Cold Weather
amps amps watts
.14
.22 18.2
2
4.8
.13
.28
29.1
1
3.3
.13
.26
16.6
2
5.2
.13
.31
24.5
1
2.2
.10
.17
17.0
2
3.2
.09
.24
27.3
1
2.5
.10
.19
12.2
2
4.0
.10
.27
24.2
1
6.7
.11
-
-
2
7.8
.11
-
-
1
6.9
.04
-
-
2
8.0
.04
-
-
Back Mount
BATTERY
Sealed Nickel-Cadmium
Type
STD
CW
Shelf
life3
3 yrs.
3 yrs.
Expected
life3
7-9 yrs.
7-9 yrs.
Maintenance
none4
none4
Optimum
temperature 5
10oC - 40oC
-40Co - 40oC
Top Mount
Single-Face
Notes:
1 Based on continuous operation.
2 Two-lamp version available with double-face only.
3 At 77 oF (25oC ).
4 Periodic system status test recommended.
5 Optimum ambient temperature range where unit will provide capacity for 90 minutes.
Higher and lower temperatures affect life and capacity. Consult factory for detailed
information.
Top Mount
Double-Face
KEY FEATURES
NEMA 4X Mounting Plate
4-3/8"
(111)
Unique LEDs provide extremely
long life and low energy
consumption.
UL approved for damp, NEMA
4X wet or cold locations (see
options).
4-3/8"
(111)
Housing or canopy mounting bracket should be attached to mounting surface using
suitable fastener for type of wall material. All four mounting hole positions should be used,
and anchors or screws should have a minimum pullout rating of 160 lbs. Bracket will only fit
a 2-gang junction box.
Lithonia Lighting
Sheet #: LV-EL-N_SE
© 1996 Acuity Brands Lighting, Inc., Rev. 6/24/08
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising