Tetra LED Systems Power Supply GEPS24W-80M

Tetra LED Systems Power Supply GEPS24W-80M
GE
Installation Guide
24
Lighting
Volt
Tetra LED Systems Power Supply
®
(GEPS24W-80M)
Power Supply Features
• Supports Tetra PowerStrip DS, Tetra miniStrip DS, Tetra EdgeStrip, Tetra Contour and Tetra Contour LS LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV)
• IP66 rated: wet location rated
• M20 Thread
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before
servicing or installing product.
• Properly ground Tetra® power supply.
RISK OF FIRE
• Use only Tetra® supply wire to make connection from
Tetra® power supply to Tetra® LED strip.
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82 mm2)
• Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
• N’utilisez que le fil d’approvisionnement Tetra® pour faire la connexion entre
l’alimentation Tetra® et la bande DEL Tetra®.
• N’utilisez que des fils approuvés pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82 mm2).
• Respectez tous les codes locaux.
CAUTION/ATTENTION
RISK OF INJURY
RISQUE DE BLESSURE
• While performing installations described, gloves, safety glasses • Lors de l’exécution des installations décrites, des gants, des lunettes de or goggles should be worn.
sécurité ou des lunettes de protection doivent être portées.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• Limited to use in dry and damp locations.
• The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code (NEC) Article 600.
• Follow all National Electric Codes (NEC) and local codes.
• These products are only suitable for connection to a circuit from a Class 2 power source. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies.
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must
accept any interference received, including interference that
may cause undesired operation.
Note: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
This Class [A] RFLD complies with the Canadian standard
ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005
du Canada. © CURRENT 2017
Power Supply Installation
Power supply input wires
NOTE: All electrical connections
should be made within the letter.
Red (+)
Power supply
To power supply
Conduit
AC Line
Blue (+)
Green with
yellow stripe
White (-)
Black (-)
Red stripe (+)
1
Run AC line through conduit and
attach conduit to outdoor-rated
enclosure. Attach power supply
to enclosure.
2
Connect the red stripe wire (+) of the
LED strip to the red wire (+) of the
power supply. Connect the white
wire (-) of the LED strip to the black
wire (-) of the power supply.
4
Mount power supply in a horizontal
orientation with a minimum of one
screw per mounting plate (two
screws per power supply).
5
Tighten liquid-tight fittings and
properly replace cover on junction
box to ensure a water-tight seal.
Brown (-)
3
Connect the AC line to the brown (line)
and blue (neutral) input wires of the
power supply using 18-14 AWG (0.822.08 mm2) twist-on wire connectors.
Properly ground (green wire with
yellow stripe) power supply in
accordance with National Electric
Code (NEC) Article 600. NOTE: For CSA approval, a disconnect/toggle switch of appropriate rating needs to be placed within 29.5 ft. (9 m) of primary side of the
power supply. The minimum rating of the switch must be either 120 or 220 Volts AC. The switch must also support twice the amount of
input current.
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and neutral
connections, in accordance with local, state or country regulations.
NOTE: The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code (NEC)
Article 600.
Retrofit Instructions
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and associated transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.
NOTE: Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in all holes 0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an aluminum or zinc coated steel patch with rivets and sealant.
5. Using the layout guidelines within the LED module installation instructions, determine required number of LED modules required to illuminate the sign.
6. Using the applicable LED module maximum Loading chart, determine the number of Tetra Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload any single power supply output.
7. Follow the LED module instructions to properly mount the LED modules.
8. Connect the DC output of the power supply to the LED modules using the Power Supply Installation instructions above.
9. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the Power Supply Installation instructions above.
10. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, and country electrical codes.
Power Supply Specifications
Performance Data
Min
Typical
Max
Input Voltage (VAC)
264
90
100-240
Input Frequency (Hz)
-
50/60
-
Input Current (A)
-
-
1.2
Output Voltage (VDC)
23
24.3
25.6
Output Current (ADC)
-
-
3.3
Output Power (W)
-
-
80
Environmental Operating Temperature Range
-40°C
+25°C
+60°C*
Environmental Humidity (non-condensing)
0%
-
95%
Environmental Storage Temperature Range
-40°C
-
+85°C
Dimensions
12 in. x 2 in. x 1.25 in. (307 mm x 52 mm x 32 mm)
* Maximum case temperature is 80°C
Supports
Tetra
Products
Tetra
PowerStrip
SS
SKUs
GESS2471-2, GESS2450-2,
GESS2441-2, GESS2432-2
GESS24H71-1, GESS24H50-1,
GESS24H41-1, GESS24H32-1
Tetra
GEDS71-2, GEDS50-2,
PowerStrip GEDS41-2, GEDS32-2
DS
GEDSH71-2, GEDSH50-2,
GEDSH41-2, GEDSH32-2
Tetra
GEWHBDP6, GEWWBDP6-50K,
miniStrip GEWWBDP6-41K, GEWWBDP6
DS
GEBDH71-1, GEBDH50-1,
GEBDH41-1, GEBDH32-1
Tetra
GEBI71-2, GEBI50-2,
EdgeStrip GEBI41-2, GEBI32-2
GEBIH71-2, GEBIH50-2,
GEBIH41-2, GEBIH32-2
Tetra
GEXNLRD-1
Contour
LS
GEXNLBL-1, GEXNLGL-1
Tetra
Contour
Rated Watts
Maximum Load
2.52W/module
30 modules/30 ft. (9.14 m)
2.9W/module
22 modules/22 ft. (6.71m)
5.04W/module
14 modules/14 ft. (4.27 m)
5.80W/module
12 modules/12 ft. (3.66 m)
2.20W/module
31 modules/31 ft. (9.45 m)
2.98W/module
24 modules/24 ft. (7.32 m)
2.52W/module
30 modules/30 ft. (9.15 m)
5.40W/module
14 modules/14 ft. (4.27 m)
1.30W/ft. (strip)
58 ft. (17.68 m)
1.73W/ft. (strip)
44 ft. (13.41 m)
GEXNL65-1, GEXNL32-1
3.17W/ft. (strip)
24 ft. (7.3 m)
GEXNBL-1, GEXNGL-1, GEXNRD-1
1.52W/ft. (strip)
50 ft. (15.24 m)
GEXNYG-1, GEXNRC-1
2.27W/ft. (strip)
33 ft. (10.06 m)
GEXN65-1, GEXN32-1
3.17W/ft. (strip)
24 ft. (7.3 m)
Chart continued on next page
Remote Mounting Distance
18 AWG/ 16 AWG/ 14 AWG/ 12 AWG/
0.82 mm2 1.31 mm2 2.08 mm2 3.31 mm2
20 ft.
25 ft.
35 ft.
40 ft.
(6.1 m)
(7.6 m)
(10.6 m)
(12.1 m)
20 ft.
25 ft.
35 ft.
40 ft.
(6.1 m)
(7.6 m)
(10.6 m)
(12.1 m)
20 ft.
25 ft.
35 ft.
40 ft.
(6.1 m)
(7.6 m)
(10.6 m)
(12.1 m)
20 ft.
25 ft.
35 ft.
40 ft.
(6.1 m)
(7.6 m)
(10.6 m)
(12.1 m)
20 ft.
25 ft.
35 ft.
40 ft.
(6.1 m)
(7.6 m)
(10.6 m)
(12.1 m)
20 ft.
25 ft.
35 ft.
40 ft.
(6.1 m)
(7.6 m)
(10.6 m)
(12.1 m)
20 ft.
25 ft.
35 ft.
40 ft.
(6.1 m)
(7.6 m)
(10.6 m)
(12.1 m)
20 ft.
25 ft.
35 ft.
40 ft.
(6.1 m)
(7.6 m)
(10.6 m)
(12.1 m)
20 ft.
30 ft.
50 ft.
86 ft.
(6.1 m)
(9.1 m)
(15.2 m)
(26.1 m)
20 ft.
30 ft.
50 ft.
86 ft.
(6.1 m)
(9.1 m)
(15.2 m)
(26.1 m)
20 ft.
30 ft.
50 ft.
86 ft.
(6.1 m)
(9.1 m)
(15.2 m)
(26.1 m)
20 ft.
30 ft.
50 ft.
86 ft.
(6.1 m)
(9.1 m)
(15.2 m)
(26.1 m)
20 ft.
30 ft.
50 ft.
86 ft.
(6.1 m)
(9.1 m)
(15.2 m)
(26.1 m)
20 ft.
30 ft.
50 ft.
86 ft.
(6.1 m)
(9.1 m)
(15.2 m)
(26.1 m)
Chart continued
Supports
Tetra
Products
Line Fit Light
SKUs
GEF12DHOLED-1
GEF12SGNHOLED-1
GEF12CWHOLED-1
GEF18DHOLED-1
GEF18SGNHOLED-1
GEF18CWHOLED-1
GEF24DHOLED-1
GEF24SGNHOLED-1
GEF24CWHOLED-1
GEF30DHOLED-1
GEF30SGNHOLED-1
GEF30CWHOLED-1
GEF36DHOLED-1
GEF36SGNHOLED-1
GEF36CWHOLED-1
GEF42DHOLED-1
GEF42SGNHOLED-1
GEF42CWHOLED-1
GEF48DHOLED-1
GEF48SGNHOLED-1
GEF48CWHOLED-1
GEF60DHOLED-1
GEF60SGNHOLED-1
GEF60CWHOLED-1
GEF64DHOLED-1
GEF64SGNHOLED-1
GEF64CWHOLED-1
GEF72DHOLED-1
GEF72SGNHOLED-1
GEF72CWHOLED-1
GEF84DHOLED-1
GEF84SGNHOLED-1
GEF84CWHOLED-1
GEF96DHOLED-1
GEF96SGNHOLED-1
GEF96CWHOLED-1
Rated Watts
Maximum Load
5.8W/bar
12 ft.
7.2W/bar
12 ft.
11.5W/bar
Remote Mounting Distance
18 AWG/ 16 AWG/ 14 AWG/ 12 AWG/
0.82 mm2 1.31 mm2 2.08 mm2 3.31 mm2
_
_
_
_
12 ft.
_
_
_
_
14.4W/bar
12 ft.
_
_
_
_
17.3W/bar
12 ft.
_
_
_
_
20.2W/bar
12 ft.
_
_
_
_
23.0W/bar
12 ft.
_
_
_
_
28.8W/bar
12 ft.
_
_
_
_
30.2W/bar
12 ft.
_
_
_
_
34.6W/bar
12 ft.
_
_
_
_
40.3W/bar
12 ft.
_
_
_
_
46.1W/bar
12 ft.
_
_
_
_
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
Conforms to the following standards:
www.currentbyge.com, www.gelighting.com
All trademarks are the property of their respective owners. Information provided is subject to
change without notice. All values are design or typical values when measured under laboratory
conditions. Current, powered by GE is a business of the General Electric Company.
© 2017
SIGN201 (Rev 04/11/17)
GE2022-3612
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising