Secondary Underground Distribution Aluminum XLPE USE

Secondary Underground Distribution Aluminum XLPE USE
FlexGlide™ Mobile Home Feeder AA-8000 - Tri-Rated
Compact Conductor, XLPE Insulated, 600 V
Features
AA-8000 Series aluminum
alloy conductor for increased
flexibility.
Use of lubrication is not
mandatory to install FlexGlide™
conductors in the raceways.
Annealed conductor of AA-8000
aluminum alloy are easy to bend
for increased flexibility and less
springback.
Excellent insulation properties
for sunlight resistant, moisture
resistant, and flame retardant.
Resistant to tear and abrasion.
Suitable for direct burial.
Complete cable is Lead Free and
RoHS compliant.
Used for secondary distribution
and underground service at 600 V
or less.
May be used in ducts or direct
burial.
Application
These cables are designed
to connect mobile homes to
an electrical supply where
permanent wiring is required.
It can also be used for general
purpose wiring in circuits not
exceeding 600 volts.
May be used in wet or dry
locations, installed in conduit,
duct, and directly buried in
earth not exceeding 90 °C and in
accordance with requirements of
the NEC®.
Standards
1
ICEA S-105-692
2
600 V Single Layer Thermoset
Insulated Utility Underground
Distribution Cable.
3
UL 854
Service-Entrance Cables.
UL 44
3. Insulation:
Thermoset-Insulated Wire and
Cable.
Two Phase conductors:
Black thermoset cross-linked
polyethylene (XLPE).
Specifications
Maximum operating voltage:
• 600 V
Maximum conductor operation
temperatures:
• 90 °C wet and dry
Engineering
Information
1. Conductor: Aluminum alloy
AA-8000 series, compact Class B
stranding per ASTM B801.
2. Separator: A suitable opaque
tape, as required.
Neutral conductor: Black
thermoset cross-linked
polyethylene (XLPE), with three
white extruded stripes.
Grounding conductor: Green
thermoset cross-linked
polyethylene (XLPE)
Conductor Phase ID: Ink printed.
Configurations:
Quadruplex: Two black phase
insulated conductors (A & B);
one neutral insulated conductor;
and, one green ground insulated
conductor cabled together.
CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | www.cmewire.com | 770.623.0001
© 2014 CME Wire and Cable, Inc. All Rights Reserved.
July 26, 2016
Secondary URD Cable – Aluminum
Single conductors are UL Listed
as Type RHH/RHW-2/USE-2 (aka
Triple-Rated or Tri-rated).
FlexGlide™ MHF AA-8000 - Tri-Rated, Compact Conductor, XLPE Insulated, 600 V
Technical Data
Mobile Home Feeder AA-8000 Series Tri-Rated; USE-2/RHH/RHW-2; Compact Conductor
Phase Conductor
Sizes
Part
Number
Neutral Conductor
Insulation Insulated
Size
Number Diameter Thickness Diameter
Size
AWG or
of
AWG or
mil
mil
mil
kcmil Strands*
kcmil
Ground Conductor
Cable OD
Insulation
Insulation Complete
Number Thickness Size
Number Thickness Cable
of
AWG or
of
mil
mil
in
Strands
kcmil Strands*
Net
Weight
Ampacity†
lb/kft
amp
2-2-4-6
MHF2246
2
19
269
60
389
4
7
60
6
7
60
0.842
318
100
2/0-2/0-1-4
MHF202014
2/0
19
376
80
536
1
19
80
4
7
60
1.164
395
150
4/0-4/0-2/0-4
MHF4040204
4/0
19
475
80
635
2/0
19
80
4
7
60
1.543
813
205
The above data are approximate and subject to normal manufacturing tolerances. Other sizes available upon request.
* Number of wires may vary as permitted by ASTM B801 and UL 44.
†† Ampacities are based on NEC 2014 Table 310.15(B)(16) for insulated conductors rated up to and including 2000 volts, at 90 °C for not
more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient temperature of 30 °C.
CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | www.cmewire.com | 770.623.0001
July 26, 2016
© 2014 CME Wire and Cable, Inc. All Rights Reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF