Waste Master Enclosure and Mounting Bracket Kit

Waste Master Enclosure and Mounting Bracket Kit
Doc WM81
Waste Master Enclosure and
Mounting Bracket Kit
installation instructions
for
 5th Wheels
 Travel Trailers
 Toy Haulers
WM 81-6
1 of 8
31 May 2017
‘Waste Master Pre-Install Quick Check’ per Doc WM82
should be performed first to determine basic conditions
are met for install readiness.
This document, WM81, provides detailed information to
complete the installation. Before proceeding, verify your
RV’s set up with Diagrams 1 and 2 (Pgs. 5 and 6) in hand
and establish install parameters. These steps together
with compliance to Pg.7 check list will ensure full
confidence and successful system installation
WM 81-6
2 of 8
31 May 2017
Enclosure & Mounting Bracket Attachment Method
3/8” HW Use as required from
Kit based on Drop Height - refer
Doc WM89 ‘Drop Height Table
and HW Configuration’
Mounting Bracket Kit
PN 5911
Drop Height
For Mounting
Bracket
dimensions refer
to WM88 Bracket Dwg.
Hose Enclosure
PN 5856
1/4 ” Self Tapping x ¾” L
Screws 6 places
(only 1 shown for clarity)
WM 81-6
3 of 8
31 May 2017
Installation Steps
1. Complete Check list and modifications as required per Page 7 first to confirm install readiness
2. Determine mounting X and Y as Pre Diagram 1. Mark the hole centers in I-Beam and in
Enclosure ‘Wings’
3. Establish Drop Height as per Diagram 2. Doc WM89 provides Drop Height Table and HW
Configuration. Bracket kit provides a Drop Height range from 1” to 4.5”. For Drop Height >
4.5”, longer bolts may be required. Buy or order from Drain Master.
4. If applicable, install Vent Assembly Kit with threaded Female Cam Lock fitting Per Doc. WM91
5. Mount Bracket with 6 x Self tapping ¼” screws (included); pre drill a 3/16” pilot hole to guide
and ease self tapping screws. Use permanent strength thread locker Ex: Loctite Red 271.
Torque till Bracket is firm – do not over torque or threads may strip. Typical torque 10 Ft-Lbs
6. 4” Dia. hose exit hole must be precut in the enclosure; hole location as per Diagrams. 1 and 2.
7. Enclosure wings must have predrilled holes 7/16” dia. at the bolt mounting locations
8. Mount the enclosure to the bracket with 3/8 x 16 TPI HW based on Drop Height configuration.
Not all HW items may get used, this is OK – it depends on configuration.
9. Torque guidelines: 20 Ft-lbs HW to Mounting Bracket. Torque 10 Ft-Lbs HW to ABS enclosure
‘wings’ – it’s a softer material; Use permanent strength thread locker Ex. Loctite Red 271
10. Adjust the HW to attain desired Drop height - plumbing center line & hole align within 1/8”
11. Install Hose and test out system: Extend and retract as per Doc WM90 ‘WM User Manual’
WM 81-6
4 of 8
31 May 2017
Diagram 1. – Establishing Enclosure mounting position relative to plumbing and I-Beam
(Top Down View)
4” Dia. hose exit hole
centre location from
enclosure front
X= 12”minus A, allow 2”
min. in front of I beam
Y = Allow 3” +/− ¼”
Allow 2 ½” min
plumbing extension for
Female Cam Lock install
Enclosure front
12” +/− ¼”
A
Exit Hole and plumbing
centers should line up
within 1/8”
Allow 16” Min. Overhang
behind I- Beam or Chassis
Y Reference = Exit
Plumbing Edge
A: Distance from Front of I-Beam to
sewer exit plumbing centre
Enclosure rear
WM 81-6
5 of 8
31 May 2017
Diagram 2. – Establishing Drop Height Relative to I-Beam and Plumbing Center
(As Viewed from Enclosure front)
Direct mounting of Air Release Valve* to
female Cam Loc fitting requires 5” head
room clearance. If this space is not
available use the 90 deg elbow and Vent
Kit parts to relocate the Air Release Valve
PC: Distance from I-beam bottom to sewer exit
pluming center
DH: Drop Height is distance from Bottom of IBeam to Top of enclosure = PC minus 2 ¾”.
Drop Height must be at least 1” or more
Bottom of I-Beam
DH=PC- 2 ¾”
PC
4” Dia. hose exit hole
centre is located 2 ¾”
from top of Enclosure
Exit Hole and plumbing
centers should line up
within 1/8”
4” Dia. side wall hose exit hole. Hole may be either
side wall depending on plumbing location
*Not applicable to WM 5915 Kit
WM 81-6
6 of 8
31 May 2017
Installation Check List - Ref Diagrams. 1 and 2 (Pgs 5 and 6)
Item
Requirement
Verification
Option if NO
1
Bracket Mountability
I-Beam mounting area free of
obstructions & Add-ons
[ ] Yes [ ] No
Remove obstructions if possible
or re- locate enclosure
2
Bracket Clearance
Min 2” Clear all around from
interference or obstructions
[ ] Yes [ ] No
Remove obstructions if possible
or re- locate enclosure
3
Plumbing and Hose exit
hole line up.
Within 1/8” inch as per
Diagrams 1 and 2
[ ] Yes [ ] No
Reroute or adjust plumbing
and/or enclosure location
4
Y Dimension
Enclosure locatable to meet 3”
+/− 1/4” per Diagram 1
[ ] Yes [ ] No
Reroute or adjust plumbing
and/or enclosure location
5
X Dimension
2” Min. in front of I-Beam
As per Diagram 1
[ ] Yes [ ] No
Re-plan enclosure position
6
DH: Drop Height
1” Min
[ ] Yes [ ] No
Increase DH by slightly lowering
sewer plumbing outlet.
7
Enclosure Door
Can Operate freely w/o
interference with skirting
[ ] Yes [ ] No
Relocate enclosure and reroute
plumbing
8
Encl. Rear Over Hang
16” Min. behind I-Beam
[ ] Yes [ ] No
Relocate enclosure and reroute
plumbing
9
Exit Plumbing Extension
Min 2.5 “available as per
Diagram 1.
[ ] Yes [ ] No
Add extension then re-check list
Item 4
10
Air Valve
Clearance (not applicable
to WM 5915 Kit)
5” min head room above Exit
Plumbing
[ ] Yes [ ] No
Create head room if possible or
relocate ARV using Vent kit parts
WM 81-6
7 of 8
31 May 2017
Congratulations on your successfully installing
the Waste Master permanently connected hose
system! Now you can enjoy the ultimate in
convenience.
Questions?
Comments? Need Help?
Call Toll Free: 877-787-8833
WM 81-6
8 of 8
31 May 2017