Thermo-dryer

Thermo-dryer
Thermo-dryer
New
With air temperature adjustment function
RoHS
Stable supply of temperaturee and pressure controlled dry clean air!
Possible to supply compressed Application example
Air bearing
compressed air
air with the same conditions Supplying
with constant conditions to
and quality regardless of the air bearings mounted on the tool.
season.
Compressed air
Compressed
air
Air flow capacity (L/min[ANR])
IDH;4 : 100 to 500
IDH;6 : 200 to 800
All-in-One
Machine tool
Outlet air temperature adjustment range:
Temperature
control
(Heater)
Pressure
regulation
(Regulator)
Dehumidification
(Dryer)
15 to 30°C
(possible to extend depending on the conditions)
Outlet air temperature stability:
1
±0.1°C
Outlet air set pressure range:
0.15 to 0.85 MPa
Outlet air pressure dew point:
10°C
Nominal filtration rating:
0.01 μm
Outlet oil mist concentration:
Cleaning
(Filter)
Built-in filter
MAX. 0.01 mg/m3 [ANR]
specifications
2 (z0.008 ppm)
Outlet cleanliness:
Particles of 0.3 μm or more:
3.5 particles/L [ANR] or less
1 Performance when the operation of each part is stable without fluctuations in operating conditions and power supply.
2 Performance of the built-in filter, which depends on the inlet air conditions.
Power supply available all over the world
Model
Air flow capacity
(L/min [ANR])
IDH;4
100 to 500
IDH;6
200 to 800
Single-phase 100 VAC, 200 VAC, 230 VAC (50/60 Hz)
Outlet air temperature
Outlet air set
Outlet air temperature
adjustment range (°C) pressure range (MPa)
stability (°C)
15 to 30
Series IDH ;
0.15 to 0.85
±0.1
Filter nominal
filtration rating
Temperature
control method
0.01 μm
(99.9% filtration efficiency)
Heater operation
PID control
Port size
Rc3/8
Rc1/2
P-E10-12A
Thermo-dryer
Compact,
Space saving
Installation close to a
wall is possible. Wall
498 (568)
Wall
Ve
nti
lat
ion
ho
le
Installation close to a
wall is possible with
the ventilation holes
on the front and top
sides.
Ventilation hole
Ventila
tion ho
(4
85
)
le
45
5
270
(27
0)
For IDHF4
Dimensions in brackets indicate
for IDHF6. Unit: mm
Convenient Functions
Power failure auto-restart function
Control temperature failure alarm
Even if operation is stopped by unexpected power failure, once the
power supply is recovered, the operation will start automatically.
If the temperature exceeds the set temperature by an arbitrary amount, an error signal will be generated.
If an instantaneous power failure occurs, the operation may restart
after a few minutes.
At shipment, if the control temperature exceeds or goes under the set
temperature by p5ºC, an error signal will be generated.
Auto-tuning (A·T) function
Key-lock function
The control set values (PID) are automatically set.
The set value is protected so it will not be changed even if
keys are touched by mistake or setting is changed.
Regulator handle
Large digital display
Built-in filter
The discharge of drainage and element
replacement timing can be checked visually.
3
Filter1(AME)
4
Super Mist Separator
· Nominal filtration rating:
0.01 μm (99.9% filtration efficiency)
· Outlet oil mist concentration:
MAX. 0.01 mg/m3 [ANR] (z0.008 ppm)
· Outlet oil mist concentration:
Particles of 0.3 μm or
more: 3.5 particles/L Pressure
adjustment
[ANR] or less
1
2
5
6
7
handle
Display
Function
1
PV
Displays the outlet air temperature.
2
SV
Displays the outlet air temperature set value.
(Default: 25°C)
3
C1
Lights up or flashes when the temperature
adjustment heater is operating.
4
AL1
Flashes when a control temperature error is generated.
5
SEL
This key is used to change and fix the set value.
6
?
Increases the set temperature and set values.
?
Decreases the set temperature and set values.
7
Remote operation, stop, error signal
output functions are provided.
It is possible to achieve centralized control in
a factory with remote operation, stop and
error signal output functions.
It is possible to synchronize the operation of
the dryer with the external air compressor
operation to prevent people from forgetting
to turn it off and contribute to energy saving.
Drain outlet
Dustproof filter
standard equipment
Filter0(AMH)
Built-in earth
leakage breaker
Micro Mist Separator with Pre-filter
· Nominal filtration rating:
0.01 μm (99.9% filtration efficiency)
· Outlet oil mist concentration:
MAX. 0.1 mg/m3 [ANR] (z0.08 ppm)
Akihabara UDX 15F,
4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
http://www.smcworld.com
© 2011 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
D-DN
1st printing PS printing PS 7850SZ Printed in Japan.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement