DG70J SuperSilent GENERATOR
DG125J UltraSilent GENERATOR
DG180V SuperSilent GENERATOR
DG220V SuperSilent GENERATOR
DG300K SuperSilent GENERATOR
DG400V SuperSilent GENERATOR
1-866-733-3272
Rental Centers Across North America
reddarc.com
70 KVA to 400 KVA - Single/Three Phase Generators
MODEL
DG70JSS
DG125JUS
DG180VSS
DG220VSS
DG300KSS
DG400VSS
GENERATOR
Revolving Field Self-Ventilated Dip-Proof Single Bearing
DESIGN
No. OF POLES
4 Poles
EXCITATION
Brushless with AVR
STANDBY OUTPUT
61 KW (77KVA)
110 KW (137KVA)
158 KW (198 KVA)
194 KW (242KVA)
264 KW (300KVA)
352 KW (440KVA)
PRIME OUTPUT
61 KW (77KVA)
100 KW (125KVA)
144 KW (180 KVA)
194 KW (242KVA)
264 KW (300KVA)
352 KW (440KVA)
GENERATOR RPM
1800
VOLTAGE - 3 PHASE
208, 220, 240, 416, 440, 480
VOLTAGE - SINGLE PHASE
ARMATURE CONNECTION
Star with Neutral / Zigzag
VOLTAGE REGULATION
(No Load to Full Load)
208a
120, 127, 139, 240, 254, 277
V
Star with Neutral
1.5%
1%
60 Hz (can be set for 50 Hz with reduced output)
FREQUENCY
POWER FACTOR
0.8
INSULATION
Class F
SOUND LEVEL dB (A)
(Full Load at 23 Feet)
67
63
70
72
71
72
DIESEL ENGINE
MAKE/MODEL
John Deere
John Deere
Volvo
Volvo
Komatsu
Volvo
D4045TF150
6068HF275
TAD722GE
TAD741GE
SAA6D125E-2
TAD1241GE
STARTING SYSTEM
Electric Starter
DESIGN
4-Stroke
Water Cooled
Direct Injection
Turbocharged
No Intercooler
Air to Air Intercooler
DISPLACEMENT
4500 cc
6800 cc
7150 cc
7280 cc
11040 cc
NO. OF CYLINDERS
4
6
6
6
6
12130 cc
6
BORE X STROKE (MM)
106 x 127
106 x 127
108 x 130
107 x 135
125 x 150
131 x 150
GROSS ENGINE POWER OUTPUT 99
165
296
316
431
527
HP AT RATED SPEED
90
150
218
273
354
468
FUEL TANK CAPACITY GAL (L)
40 (150)
169 (640)
79 (300)
100 (380)
129 (490)
129 (490)
FUEL CONSUMPTION
at Full Load Gph (Lph)
3.9 (14.8)
7.7 (29.0)
11.2 (42.2)
12.6 (47.8)
16.7 (63.2)
20.6 (78.1)
at 3/4 Load Gph (Lph)
3.1 (11.7)
5.8 (21.9)
8.5 (32.0)
9.7 (36.7)
12.5 (47.6)
15.4 (58.3)
at 1/2 Load Gph (Lph)
2.3 (8.7)
10.8 (41.0)
at 1/4 Load Gph (Lph) 1.8 (6.8)
COOLANT CAPACITY GAL (L)
5.9 (22.3)
3.8 (14.5)
5.9 (22.4)
7.0 (26.5)
8.5 (32.1)
2.5 (9.3)
3.7 (14.0)
4.3 (16.2)
5.0 (19.0)
6.3 (23.7)
4.43 (16.8)
7.2 (27.3)
9.8 (37.0)
9.8 (37.0)
11.6 (44.0)
OIL CAPACITY GAL (L)
3.4 (13.0)
5.25 (19.9)
9.0 (34.0)
7.7 (29.0)
16.4 (62.0)
9.2 (35.0)
BATTERY
12V 72Ah x1
12V 128Ah
12V 150Ah x 2
24V System
12V 128Ah x 2
24V System
12V 150Ah x 2
24V System
12V 150Ah x2
24V System
inches
49 x 35 x 55
120 x 49 x 73
140 x 47 x 71
144 x 52 x 69
153 x 55 x 71
166 x 56 x 83
(cm)
(240 x 90 x 140)
(305 x 124 x 186)
(355 x 120 x 180)
(365 x 130 x 175)
(389 x 140 x 180)
(420 x 140 x 210)
3219 (1460)
6031 (2735)
6515 (2955)
7696 (3490)
9415 (4270)
11136 (5050)
SINGLE PHASE 120V
155.5A (4 wire)
168A x 2 (zigzag)
277.8A (4 wire)
301A x 2 (zigzag)
400.0A (4 wire)
488.9A (4 wire)
667.7A (4 wire)
888.9A (4 wire)
SINGLE PHASE 240V
77.8A (4 wire)
168A (zigzag)
138.9A (4 wire)
301A (zigzag)
200.0A (4 wire)
244.4A (4 wire)
333.3A (4 wire)
444.4A (4 wire)
THREE PHASE 240V
168A
301A
433A
529A
722A
962A
THREE PHASE 480V
84A
150A
216A
265A
361A
481A
SIZE
L xW x H
APPROX. NET WT. DRY LB. (KG)
AMP
North America’s Largest Fleet of Welding and Positioning Equipment
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement