INSTALLATION – OPERATION – MAINTENANCE MANUAL,
LED STRIP LIGHT,
P/N 01-11-0003
P/N 01-11-0004
PROPRIETARY STATEMENT
These technical data and the designs disclosed herein are the exclusive property of
Avtec Inc. or contain proprietary rights of others and are not to be used or disclosed to
others without the written consent of Avtec Inc. The recipient of this document, by its
retention and use agrees to hold in confidence the technical data and design contained
herein. The foregoing shall not apply to persons having proprietary rights to such
technical data or such designs to the extent that such rights exist.
October 2, 2001
Revision: N/A
P21D001
i
$YWHF,QF
/LJKWLQJ6\VWHPV
List of Effective Pages
i – iii
1–6
REVISION STATUS
Revision
N/C
Description
Date
Original Release
October 2, 2001
Revision: N/A
Approved By
25FEB02
P21D001
ii
$YWHF,QF
/LJKWLQJ6\VWHPV
TABLE OF CONTENTS
PARAGRAPH
1.0
2.0
3.0
4.0
5.0
6.0
7.0
October 2, 2001
Revision: N/A
TITLE
SCOPE
GENERAL DESCRIPTION AND SPECIFICATIONS
PRODUCT SPECIFICATIONS
INSTALLATION INSTRUCTIONS
OPERATION AND CONTROL
MAINTENANCE AND CONTINUED AIRWORTHINESS
TROUBLESHOOTING TECHNIQUES
PAGE
1
1
2
4
5
6
6
P21D001
iii
$YWHF,QF
/LJKWLQJ6\VWHPV
1.0
SCOPE
This document provides installation and application data for P/N 01-11-0003 and P/N 01-11-0004,
LED STRIP LIGHT. Aircraft installations are to be done in accordance with FAA Acceptable
Methods, Techniques, and Practices.
2.0
GENERAL DESCRIPTION AND SPECIFICATIONS
LED Strip Lights are intended to provide aircraft cabin, galley and accent lighting. The LED Strip Light
is non-required electrical equipment and AC25-10 applies. Aircraft power to the system is controlled
by dedicated resettable circuit breakers. The LED Strip Lights consists of the following:
LED Strip Light: (01-11-0003)
The LED Strip Light (01-11-0003) consists of a polycarbonate Housing, a LED circuit board, a
three (3) pin male connector and a three (3) pin female connector.
LED Strip Light: (01-11-0004)
The LED Strip Light (01-11-0003) consists of a polycarbonate Housing, a LED circuit board with
power supply, a six (6) pin male connector and a three (3) pin female connector.
October 2, 2001
Revision: N/A
P21D001
1
$YWHF,QF
/LJKWLQJ6\VWHPV
3.0
3.1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PRODUCT SPECIFICATIONS
General
P/N 01-11-0004 is designed to operate from an input voltage of 28VDC.
P/N 01-11-0003 is designed to operate from an input voltage of 28VDC supplied from P/N 01-11-0004.
Lamp life is rated at 100,000 hours.
Integrated power supply.
Integrated dimming.
Integrated dim level voltage reference.
Low power consumption.
Produces very little heat.
Brighter than fluorescent lamps.
Available in warm and cool white.
Optional colors are available.
Two position mounting clips provided with all orders.
Input electrical connectors provide with all orders.
Install the system per installation instructions. See section 4.0.
3.2
Electrical Characteristics
MODEL P/N
MINIMUM
VOLTAGE
MAXIMUM
VOLTAGE
NOMINAL
VOLTAGE
NOMINAL
AMPERAGE
POWER WATTS
01-11-0004/
01-11-0003
25 VDC
32 VDC
28 VDC
360 mA/ 16”
3.0
The above input voltages assume the LED Strip Light operating at a room temperature of 25°C, 65% RH, at sea level. Normal
operating and storage temperatures are –30°C through +70°C
October 2, 2001
Revision: N/A
P21D001
2
$YWHF,QF
/LJKWLQJ6\VWHPV
3.4
Mechanical Specifications
Part Number
01-11-0003
01-11-0004
HEIGHT (A)
in
mm
0.98
24.89
0.98
24.89
WIDTH (B)
in
mm
0.55
13.97
0.55
13.97
Weight/32”
oz
gm
5.04
142.88
5.54
157.06
P/N
01-11-0004
01-11-0003
Part Number
02-11-0003
Weight / ea.
oz
gm
.12
3.40
P/N 02-11-0003
October 2, 2001
Revision: N/A
P21D001
3
$YWHF,QF
/LJKWLQJ6\VWHPV
4.0
INSTALLATION INSTRUCTIONS
4.1
General Layout
The installation should be accomplished per acceptable methods, techniques and practices, found in
FAA Advisory Circular AC43.13-1B.
4.2
Mounting
Any mounting surface in the aircraft can be chosen for the LED Strip Light. All surfaces must be
shown by analysis, to have sufficient strength (with the hardware specified) to withstand the flight,
ground and emergency landing conditions of the applicable regulations without failure.
The Mounting Clips (P/N 02-11-0003) are to be secured to a structural member with one each #6
100° countersink screw, 60 ksi ultimate tensile strength or equivalent strength hardware.
4.3
Electrical Connections
There are multiple electrical connections to be made to the LED Strip Light. Refer to chart below for
wiring connections. The chart has recommended wire type and wire sizes. The system must tie into
aircraft’s 28 VDC buss. Any aircraft buss or circuit breaker, which is being tied into, should have a
load analysis done to insure that the total load is not exceeding 80% of the rated load.
In addition, the LED Strip Light should not be tied into any buss that is reserved for critical flight
functions. If the new LED Strip Light is replacing an existing system, and the old system used more
power off the same bus that the new system is being tied into, then a load analysis is not necessary.
The LED Light Strip P/N 01-11-0004 can power up to 13.3 feet of light.
WIRE
PIN #
CONNECTION
FUNCTION
Green
Red
Brown
Yellow
Black
Purple
1
2
3
4
5
6
TTL (Low Level) GND
+28 VDC
Momentary GND
Momentary GND
-28 VDC GND
+1.2 VDC - +0.012 Output
Low Level On /Off
Input Power
Bright
Dim
Power Ground
Dim level Voltage Reference
MINIMUM WIRE
GAUGE
20 GA
20 GA
20 GA
20 GA
20 GA
20 GA
P/N 01-11-0004 will have 2 connectors:
Power Input: Molex P/N 43640-0601 6 Position Plug with pins
Strip Output: Molex P/N 43645-0300 3 Position Receptacle w/ Pins
Molex P/N 43031-0009 (Male)
Molex P/N 43030-0009 (Female)
P/N 01-11-0003 will have 2 connectors:
Strip Input:
Strip Output:
Molex P/N 43640-0301 3 Position Plug with pins
Molex P/N 43645-0300 3 Position Receptacle w/ Pins
Molex P/N 43031-0009 (Male)
Molex P/N 43030-0009 (Female)
These items are supplied to interface ships power with P/N 01-11-0004
P/N 43645-0600 Molex 6 Pin Receptacle
P/N 43030-0009 Molex 20 -24 AWG GOLD Pin (Female)
Crimp Tool:
Molex P/N 63811-2800
October 2, 2001
Revision: N/A
P21D001
4
$YWHF,QF
/LJKWLQJ6\VWHPV
5.0
OPERATION AND CONTROL
Power may be supplied to the LED Strip Light through the installation and use of a single pole switch
that controls the ON/OFF function of the LED Strip Light. The ON/OFF function switch that is required
is: 0.5 A single pole switch tied to pin 1 and connected to ground.
Dimming is accomplished through the installation and use of two 0.5 amp - single pole/momentary
switches. One switch is for control of the BRIGHT function and one switch is for control of the DIM
function.
An output voltage of 1.2 VDC (bright) to .012 VDC (dim) is provided for DIM level reference on pin 6.
October 2, 2001
Revision: N/A
P21D001
5
$YWHF,QF
/LJKWLQJ6\VWHPV
6.0
MAINTENANCE AND CONTINUED AIRWORTHINESS
The Avtec LED Strip Light is a ‘non required – non essential’ item and therefore has no effect on the
airworthiness of an aircraft. With this in mind, the practice of ‘ON CONDITION/CONDITION
MONITORING’ applies. The concept of ‘on condition/condition monitoring’ as it applies to the Avtec
LED Strip Light requires that NO system components are removed for servicing, as long as the
systems output light and dimming functions correctly. The Avtec LED Strip Light is designed to
provide many years of safe, continuous and worry free operation. There are no component overhaul
or replacement HARD TIME limitations imposed upon any of the LED Strip Light components at this
time.
7.0
TROUBLESHOOTING TECHNIQUES
Follow these general techniques to isolate any problems:
•
Verify power to the unit, check that +28 VDC is applied to the proper
Wire(s) on the unit. Use a voltmeter to verify correct level.
•
Recheck all connections to the unit for security. Check all harness’s
for possible breaks. Recheck all wires for correct connections.
If the above techniques do not resolve your problems, contact an Avtec Technical Representative
for assistance.
--- END OF REPORT ---