Temperature Sensor with M12 hygienic
SENSORS FOR FOOD AND BIOPHARMA.
Product Information TFP-42, -52, -62, -162, -182
FOOD
Temperature Sensor with M12 hygienic
Application / Specified Usage
Authorizations
· Temperature Measurement in pipes DN15...DN80
· Temperature measurement in thin-walled pipes and vessels
Application Examples
· Process monitoring
· Monitoring of CIP- / SIP-process
· Temperature measurement in UHT-plants
TYPE EL
March 2006
Temperature Sensor TFP-42
Hygienic Design / Process Connection
· Flow optimized, hygienic and easy sterilizable installation by using Negele
weld-in sleeve, e.g. EMK-032 or build-in system, e.g. EHG-... / M12
· Additional process connections: adapters for TriClamp, dairy fl ange (DIN 11851),
Varivent, DRD, APV et al
· Sealing system free of elastomers, the connection will be without gaps and
crevices
· Product contacting materials compliant to FDA
· Sensor completely made of stainless steel
Features / Advantages
· Integrated transmitter optional
· Different electrical connections available
Options / Accessories
· 2 x Pt100 (not retrofittable)
· 2 x Pt100 with two transmitters (not retrofittable)
· Programmable transmitters MPU-4 as well as MPU-M with output
4...20 mA, 2-wire
· Integrated transmitters for Profibus PA and HART-protocol
· Integrated transmitter MPU-LCD with display in connecting head
· Programming adapter MPU-P 9701
· Pt100 chip with other classes of accuracy (1/3B, 1/10B)
· Sensor tips with diameter 3 mm and 4 mm
· Spacer for high temperature up to 250 °C
permanent temperature up to 600 °C (on request)
· Pre-assembled connecting cable for M12-plug
· Fixed cable in other lengths and other material available
· Calibration certificate (optional with order)
Temperature Sensor TFP-162 with
transmitter MPU-M
Specification
FOOD
Temperature sensor
Process connection
thread
Tightening torque
M12 CLEANadapt; combined with Negele weld-in sleeves,
build-in-systems, adapter sleeves
10 Nm
Insertion length
standard
20...500 mm
Materialis
connecting head
thermowell
stainless steel 1.4305
stainless steel 1.4404
Operating pressure
50 bar maximum
Temperature ranges
ambient
sensor tip
-50...+80 °C
-50...+250 °C
Sensing resistor
acc. to DIN EN 60751
Pt100
Electrical connection
cable gland
cabel connection
fixed cable 2,5 m
fixed cable 2,5 m (>90 °C)
M16 x 1,5
M12-plug 1.4305, 4-pins
LIYY 4 x 0,25 mm²
PTFE 4 x 0,14 mm²
Protection class
IP 69 K (with electrical connection M12-plug)
Transmitter MPU-4, MPU-10, MPU-H, MPU-M
Temperature ranges
ambient
storage
-40...+85 °C
-55...+90 °C
Measuring ranges
MPU-4, MPU-H, MPU-M
standard: -10...40 °C, 0...50 / 100 / 150 / 200 °C
special ranges free programable
standard: -200...850 °C
configuration occurs with Profibus
MPU-10
Accuracy
input
< ±0.25 °C
Temperature drift
zero, span
< 0.01 % / K
Supply
MPU-M, MPU-4
MPU-10
accuracy
8...35 V DC
9...32 V DC
0.01 % / V (reference: 12 V DC)
Output
signal
accuracy
burden
analog 4...20 mA (not for MPU-10)
< ±0.1 % of measurement range
< 600 Ω (at U B = 24 V)
Humidity
without condensation
0...98 %
Accuracy classes of temperature sensors | Tolerances for Pt100 acc. to DIN EN 60751
Pt100
A
1/3 B
1/10 B
0 °C / 100 Ω
±0.15 K / ±0.06 Ω
±0.10 K / ±0.04 Ω
±0.03 K / ±0.01 Ω
100 °C / 138.5 Ω
±0.35 K / ±0.13 Ω
±0.27 K / ±0.10 Ω
±0.08 K / ±0.03 Ω
2
3
Electrical Connection
FOOD
Elektrischer
Electrical
connection
Anschlusswithout
ohne Kopftransmitter
transmitter
Elektrischer
Electrical
connection
Anschlusswith
mit transmitter
Kopftransmitter
With 1 x M12 plug
M12-Stecker
With
M12 plug
Belegung
Configuration
1. M12-Stecker
1st M12 plug
Configuration
M12 plug
Belegung
M12-Stecker
1 2
1: + supply
2: - supply 4...20 mA
3: not connected
4: not connected
3 4
Mit Kabelverschraubung
With
cable gland
With 2 x M12 plug
Belegung
Configuration
2. M12-Stecker
2nd M12 plug
1 2
3 4
4...20 mA current loop
4...20 mA Stromschleife
With cable gland
Belegung
Configuration
Klemmen
strip terminal
1 2
3 4
Electrical connection with two transmitter (TFP-62)
Klemmen
clamps forfür
1st1.Pt100
Pt100
Klemmen
clamps forfür
2nd
2. Pt100
Pt100
(bei
(at version
Ausführung
2 x Pt100)
2 x Pt100)
With fixed cable
Belegung
Fixed cable
Kabel
connection
mit
1
with
x Pt100
1 x Pt100
With 1 x M12-plug (sensor 1 + sensor 2)
Configuration M12-plug
1: + supply (sensor 1)
2: - supply 4...20 mA (sensor 1)
3: - supply 4...20 mA (sensor 2)
4: + supply (sensor 2)
With 2 x M12-plug (sensor 1)
Configuration M12-plug
1: + supply (sensor 1)
2: - supply 4...20 mA (sensor 1)
3: not connected
4: not connected
Fixed cable
Belegung
Kabel
connection
mit
2 x Pt100
with
2 x Pt100
(LIYY)(LIYY)
Fixed
Belegung
cable
Kabel
connection
mit
with
2 x Pt100
2 x Pt100
(PTFE)(PTFE)
With 2 x M12-plug (sensor 2)
Configuration M12-plug
1: + supply (sensor 2)
2: - supply 4...20 mA (sensor 2)
3: not connected
4: not connected
Dimensional Drawings
FOOD
TFP-42 | TFP-42.2
TFP-62
TFP-52 | TFP-52.2
Important advice for TFP-52 und -52.2
Tighten the sensor only at the lower, marked in yellow spanner flat
(BE = 17 mm)!
TFP-162
TFP-162 / ... / MPU-M
TFP-182 | TFP-182.2
4
5
Dimensional Drawings
FOOD
Sensor tip diameter and response time
All temperature sensors are available with smaller sensor tips, to ensure a shorter response time. The below-mentioned
times were measured by emersing a temperature sensor from room temperature into boiling water.
Sensor tipe Ø 6 mm
Sensor tip Ø 4 mm
Sensor tip Ø 3 mm
50 %-time: t 50 ≤ 3,0 s
90 %-time: t90 ≤ 8,0 s
50 %-time: t 50 ≤ 2,4 s
90 %-time: t90 ≤ 6,5 s
50 %-time: t 50 ≤ 0,5 s
90 %-time: t90 ≤ 1,5 s
Ø6
Ø6
Ø6
Ø4
Ø3
Installation | Warnings
FOOD
Mechanical Connection / Installation
Conventional Usage
· Use only Negele CLEANadapt system for
safe operation of measuring point!
· Not suitable for applications in explosive areas.
Transport / Storage
Reshipment
·
·
·
·
·
·
·
· Sensors shall be clean and free of media or heat-conductive paste and must not be contaminated
with dangerous media!
No outdoor storage
Dry and dust free
Not exposed to corrosive media
Protected against solar radiation
Avoiding mechanical shock and vibration
Storage temperature -55...+90 °C
Relative humidity maximum 98 %
· Not suitable for applications in security-relevant
equipments (SIL).
· Use suitable transport packaging only to avoid
damage of the equipment!
Cleaning / Maintenance
Standards and Guidelines
· In case of using pressure washers, dont‘t point nozzle
directly to electrical connections!
· You have to comply with applicable regulations and
directives.
Disposal
· This instrument is not subject to the WEEE directive
2002/96/EC and the respective national laws.
· Pass the instrument directly on to a specialised
recycling company and do not use the municipal
collecting points.
Advice to EMC
· The device agrees to following standards:
EMC directive 2004/108/EC.
· You have to guarantee the EMC directives for the
entire equipment.
Temperature Transmitter MPU-LCD with Display
Application / Specified Usage
· 4...20mA transmitter with LCD for Pt100 temperature sensor
· For installation in temperature sensor
· Sensor monitoring
Features
·
·
·
·
4-digit display with green backlight
Temperature measurement in °C and °F
Easy range select by one button
Lower costs for wiring because of 2-wire technology
Note
See product information „MPU-LCD“ for details.
Option MPU-LCD
(display in the connection head)
6
7
Order Code
FOOD
Order code for version with 1 x Pt100
TFP-42
TFP-52
TFP-162
TFP-182
(connecting head Ø 55 mm)
(connecting head Ø 55 with spacer)
(connecting head Ø 18 mm, electrical connection via M12-plug)
(connecting head Ø 18 mm,electrical connection via 2,5 m PVC-cable; other lengths: see accessories;
no transmitter possible!)
Sensor length EL in mm
020...500
(in steps of 5 mm)
xxx
(special length)
Diameter thermowell in mm (only selectable at sensor length > 30 mm)
4
(only with sensor tip 4 mm)
6
Diameter sensor tip in mm
3
4
6
(only with thermowell 6 mm)
(only with thermowell 6 mm, standard when sensor length ≤ 30 mm)
(only with thermowell 6 mm)
Accuracy class Pt100
A
1/3B
1/10B
Electrical connection
(not selectable at TFP-162 and -182)
PG
(cable gland M16x1,5)
M12
(M12 plug, standard with MPU-LCD)
Transmitter
X
(without)
for TFP-42 and -52
MPU-4
(programmable)
MPU-10
(Profibus PA)
MPU-H
(HART-protocol)
MPU-LCD
(with display)
only for TFP-162 (not for TFP-182)
MPU-M
(programmable)
Measuring range MPU
(only for types with transmitter;
not for MPU-LCD)
-10...40
(range -10...40 °C)
0...50
(range 0...50 °C)
0...100
(range 0...100 °C)
0...150
(range 0...150 °C)
0...200
(range 0...200 °C)
xx...yy
(special range)
TFP-42 /
050 /
6/
4/
A/
PG /
Accessories
PVC-cable with M12-connection made of 1.4305, IP 69 K, unshielded
M12-PVC / 4-5 m
PVC-cable 4-pin, length 5 m
M12-PVC / 4-10 m
PVC-cable 4-pin, length 10 m
M12-PVC / 4-25 m
PVC-cable 4-pin, length 25 m
PVC-cable with M12-connection, brass nickel-plated, IP 67, shielded
M12-PVC / 4G-5 m
PVC-cable 4-pin, length 5 m
M12-PVC / 4G-10 m
PVC-cable 4-pin, length 10 m
M12-PVC / 4G-25 m
PVC-cable 4-pin, length 25 m
MPU-4 /
0...100
PVC-cable with M12-connection
Product Information TFP-42, -52, -62, -162, -182
FOOD
Order code for version with 2 x Pt100
TFP-42.2
TFP-52.2
TFP-62
TFP-62-H
TFP-182.2
(connecting head Ø 55 mm, 2 x Pt100, no transmitter possible!)
(connecting head Ø 55 mm, 2 x Pt100, with spacer, no transmitter possible!)
(higher connecting head Ø 55 mm, 2 x Pt100, prepared for 2 x transmitter)
(like TFP-62, but with spacer)
(connecting head Ø 18 mm, electrical connection 2,5 m PTFE-cable; other lengths: see at accessories)
Sensor Length in mm
020...500
(in steps of 5 mm)
xxx
(special length)
Diameter thermowell in mm (only selectable at sensor length > 30 mm)
4
(only with sensor tip 4 mm)
6
Diameter sensor tip in mm
3
(only with thermowell 6 mm)
4
(only with thermowell 6 mm, standard when sensor length ≤ 30 mm)
6
(only with thermowell 6)
Accuracy class Pt100
A
1/3B
1/10B
Electrical connection (only for TFP-42.2 and TFP-52.2)
PG
(cable gland M16x1,5)
2 x PG
(2 x cable gland M16x1,5)
2 x M12
(2 x M12-plug)
Electrical connection (only for TFP-62 and TFP-62-H)
M12
(M12-plug)
2 x M12
(2 x M12-plug)
Continue if TFP-62 or TFP-62-H is selected!
No further options for TFP-42.2, -52.2, -182.2!
1. Transmitter
MPU-4
(programmable)
Measuring Range 1. MPU
-10...40
(measuring range -10...40 °C)
0...50
(measuring range 0...+50 °C)
0...100
(measuring range 0...+100 °C)
0...150
(measuring range 0...+150 °C)
0...200
(measuring range 0...+200 °C)
xx...yy
(special range)
2. Transmitter
MPU-4
(programmable)
Measuring Range 2. MPU
-10...40
(-10...40 °C)
0...50
(0...+50 °C)
0...100
(0...+100 °C)
0...150
(0...+150 °C)
0...200
(0...+200 °C)
xx...yy
(special)
TFP-62 /
100 /
6/
X/
A/
M12 /
MPU-4 /
0...50 /
MPU-4 /
0...50
50009 / 6.0 / 2015-01-13 / TB / EU
NEGELE MESSTECHNIK GMBH
Raiffeisenweg 7
87743 Egg an der Guenz
Phone +49 (0) 83 33 . 92 04 - 0
Fax +49 (0) 83 33 . 92 04 - 49
[email protected]
Tech. Support:
[email protected]
Phone +49 (0) 83 33 . 92 04 - 720
8
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF