non-contact ac voltage probe sp3000

non-contact ac voltage probe sp3000
NON-CONTACT AC VOLTAGE PROBE
SP3000
Capture Voltage Signals
from Outside the Wire Cover
The world’s first non-contact probe transforms
the conventional approach to electric equipment maintenance.
Measure signals from electric equipment on vehicles,
capture LIN and other communications signals, carry out benchmark testing, etc.
2
Do you have trouble capturing signals from
electric equipment and communication lines
because of these issues?
The miniaturization of devices and use of waterproof connectors
makes it impossible to establish contact with metal terminals
Connectors can’t be removed because it will reduce the
ability to reproduce the phenomena
Need to avoid tearing the wire insulation so as to prevent
risk of damage to the sensor due to static electricity
O2
sensor
A/F sensor
Cam angle
sensor
Knock
sensor
Injector
Actual observed
waveform
Wheel
speed
sensor
Ignition coil
LIN
Crank
position
sensor
3
Dramatically reduce work time by using the SP3000 with an
oscilloscope to observe waveforms
Visualize signals from electric equipment simply
by applying the probe to the wire’s insulation
Measure insulated wires with
outside diameters ranging
from 1 mm to 2.5 mm
10 Hz to 100 kHz
frequency band
5 Vrms 14 Vp-p
rated measurement voltage
Excellent Characteristics
Delivers stable frequency
characteristics across a
broad band so that you can
observe everything from
mechanical response signals to
communications signals.
Gain [dB]
*Cannot be used to measure DC signals
from batteries, etc.
*Cannot be used to measure uninsulated
conductors.
10.0
0.0
-10.0
-20.0
-30.0
-40.0
1
10
100
1k
10k
Sine wave
Base signal
SP3000 output
10 Hz
1 kHz
100 kHz
1 kHz
100 kHz
1 kHz
100 kHz
Rectangular wave
Base signal
SP3000 output
10 Hz
Triangular wave
Base signal
SP3000 output
10 Hz
100k
1M
Frequency [Hz]
Electrode
Measurement principle
Current = 0
SP9001
Signal
source
ground
Balanced
voltages
Measured voltage
Specifications
Voltage
generator
SP3000
Generated voltage
Measurement method
Probe service life
Maximum input voltage
Dimensions and mass
Cable length
Operating temperature
and humidity range
Insulated wire
Output rate
Rising time
Frequency band
Voltage measurement
precision
Effects of wire under
measurement
1.0 mm to 2.5 mm (0.039 in to 0.098 in)
Capacitive-coupled current cancelation
(not suitable for use with bare conductors)
10,000 open / close cycles
RMS : 30 Vrms or less
Peak : 42.4 Vpeak or less
15.0 mm (0.59 in) (W) × 13.9 mm (0.55 in) (H) × 77.4 mm
(3.05 in) (D) mm, 52 g (1.83 oz) (including cable)
1.0 m (3.28 ft)
Temperature: -10°C to 50°C (probe tip, -10°C to 80°C)
Humidity: 80% RH from -10°C to 40°C (non-condensing)
60% RH from 40°C to 80°C (non-condensing)
Temperature coefficient
Output noise
Dimensions and mass
Cable length
Operating temperature
and humidity range
Storage temperature and
-20°C to 60°C, 80% RH (non-condensing)
humidity range
Safety: EN 61010
Standard compliance
Maximum input voltage
1 V/V
4.5 μs or less
10 Hz to 100 kHz (-3 dB)
±2.5% rdg. ±1% f.s. (0.5 Vrms to 5 Vrms)
±5% rdg.
Add 0.1% rdg. per °C within operating temperature range (at
temperatures other than 23°C ±5°C)
100 mV rms (reference value)
120 mm (4.72 in) (W) × 25 mm (0.98 in) (H) × 55 mm (2.16
in) (D), 160 g (5.64 oz) (including cable)
1.5 m (4.92 ft)
Temperature: -10°C to 50°C
Humidity: 80% RH from -10°C to 40°C (non-condensing)
60% RH from 40°C to 50°C (non-condensing)
Storage temperature and
-20°C to 60°C, 80% RH (non-condensing)
humidity range
Safety: EN 61010
Standard compliance
EMC: EN 61326
USB bus power USB mini receptacle: 5 V ±0.25 V DC
Power
5 V DC, 2.6 A
AC Adapter
supply
Rated supply voltage: 100 V to 240 V AC (50 Hz/60 Hz)
Z1013
Anticipated transient overvoltage: 2500 V
When operating on USB bus power: 1.5 VA
When using AC Adapter Z1013: 7.5 VA (including AC
Maximum rated power
adapter)
NON-CONTACT AC VOLTAGE PROBE SP3000
Probe signal input
terminal
Ground input terminal
Output terminal
Rated measurement
voltage
The hook on the tip of the probe contains
an electrode for establishing capacitive
coupling with the cable being measured,
causing a minuscule current to flow if
there is a potential difference between the
cable and the electrode. By detecting this
minuscule current and generating a voltage
so as to eliminate it, the SP3000 can
accurately observe a variety of waveforms.
(Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
AC VOLTAGE PROBE SP9001
Measurable wire type
Outside diameter of
measurable wires
To
oscilloscope
BNC
Banana input
Insulated BNC
5 V rms (14.14 Vp-p)
RMS: 30 Vrms or less
Peak: 42.4 Vpeak or less
NON-CONTACT AC VOLTAGE PROBE (package)
Model No. (Order Code) : SP3000-01
Package contents
Waveform
output BNC
AC VOLTAGE PROBE SP9001
To oscilloscope
NON-CONTACT
AC VOLTAGE PROBE SP3000
Alligator clip/ground connection cable
Z1013, etc.
To USB receptacle
USB cable with bus power
AC VOLTAGE PROBE SP9001
NON-CONTACT AC VOLTAGE PROBE SP3000
Alligator clip
Ground connection cable (1.5 m)(4.92 ft)
USB cable (1.5 m)(4.92 ft)
User manual
Options
Accessories
Alligator clip
USB cable
Ground
connection cable
Non-contact AC Voltage Probe SP3000
Accessories
Alligator clip, ground connection cable (1.5 m)
(4.92 ft), USB cable (1.5 m)(4.92 ft), user manual
AC Voltage Probe
SP9001
AC Adapter
Z1013
Magnetic Adapter
9804-02
Carrying Case
C1011
Protective Cap
For SP9001 probe tip
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
HIOKI (Shanghai) SALES & TRADING CO., LTD.
TEL +86-21-63910090 FAX +86-21-63910360
http://www.hioki.cn / E-mail: [email protected]
DISTRIBUTED BY
HIOKI SINGAPORE PTE. LTD.
TEL +65-6634-7677 FAX +65-6634-7477
HEADQUARTERS
E-mail: [email protected]
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 FAX +81-268-28-0568
HIOKI KOREA CO., LTD.
http://www.hioki.com / E-mail: [email protected] TEL +82-2-2183-8847 FAX +82-2-2183-3360
E-mail: [email protected]
HIOKI USA CORPORATION
TEL +1-609-409-9109 FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: [email protected]
All information correct as of Feb. 9, 2017. All specifications are subject to change without notice.
SP3000E1-72B
Printed in Japan