MH202 Scenario programmer

MH202 Scenario programmer
Scenario programmer
MH202
Description
This device can be used to manage up to 300 simple and advanced scenarios.
Using the scenario programmer, the MY HOME system can perform certain actions not
only following a command by the user but also as a result of external events.
The execution of an advanced scenario based on a set time and date, or the arming/
disarming of the burglar alarm system, may initiate, for example, the simulation of a
presence inside the home, by automatically activating the rolling shutters or the lights
at certain preset times, when no one is in fact at home. MH202 cannot engage and
disengage. It can perform scenarios according to the status of the anti-intrusion system.
Scenarios are programmed on the device using the MyHOME_Suite software, which is
available to download from the website www.homesystems-legrandgroup.com.
Front view
1
2
3
4
Legend
Technical data
Power supply from SCS BUS: 18-27 Vdc
Max. absorption: 55 mA
Operating temperature:
5 – 45 °C
1. RJ 45 for 10/100 Mbit Ethernet LAN
2. USB port for configuration via PC and firmware upgrading
3. User interface:
- System: When the power supply is connected, it comes on, goes off, and then
comes on again, to indicate that the gateway is working
- Speed: Connection Speed: on = 100 Mbit; off = 10 Mbit - Link: ON it indicates the
presence of the Ethernet network
4. 2-wire BUS for connecting to the BUS
Dimensional data
6 DIN modules
MQ01013-b-EN
06/05/2015
1
Scenario programmer
MH202
Configuration
Personal Computer
with MyHOME_Suite software
For device configuration, the MyHOME_Suite software, available to download from the
website www.homesystems-legrandgroup.com, must be used, for creating scenarios
(actuation of light points, rolling shutters, etc.) of different degrees of complexity, based
on time events or events detected on the system (alarms, pushbuttons pressed, etc.). If
the scenario is activated by a control device (configured with M=CEN), it will be possible
to associate the corresponding key to the scenario itself.
In the same way, it is possible to upload the files from the device to check the saved
configuration. The MyHOME_Suite software enable updating of the device software, by
downloading any new versions published on the Bticino website (update firmware)
CEN operating mode
This special mode is used for managing MH202 scenario programmers, by manually
activating the control device or the MY HOME automation range set by connecting the
CEN configurator in M.
The association between the key (upper or lower) of the control device and the
scenario to be activated, is obtained using the MyHOME_Suite software. For example,
it is possible to activate two independent scenarios using the special H/L4651M2,
AM5831M2, 067553 control, using the T1 (upper) and T2 (lower) pushbuttons. For the
correspondence between the control keys and the scenarios to activate see the table
below.
In addition to the listed devices, the CEN operating mode may be managed using the
Touch Screen, the Multimedia Touch Screen, the Web Server, and a Personal Computer
with the MHVisual supervision software installed.
NOTE: The control devices configured with M=CEN mode can be connected to any point
of the system; The address specified in the A and PL positions must be different from the
addresses assigned to the actuators.
MH202 scenario
programmer
Type of control
067553, H/L4651M2 and AMS831M2 special control
Configuration Identification of scenario activation keys
T1
A=0-9; PL=0-9; M=CEN; LIV1/AUX=-; LIV2=-; SPE=-;I=-
T2
Basic control for 2 independent loads, 067552,
H/L4652/2 and AM5832/2
T1
A=0-9; PL1=0-9; M1=CEN; A2=-; PL2=-; M2=-
T2
A=0-9; PL1=0-9; M1=CEN; A2=-; PL2=-; M2=CEN
T2
T1
T4
T3
Basic control for 3 independent loads, 067554,
H/L4652/3 and AM5832/3
T2
A=0-9; PL=0-9; M=CEN; LIV1/AUX=-; LIV2=-; SPE=-;I=-
T3
T1
T6
T3
MQ01013-b-EN
2
06/05/2015
T4
Scenario programmer
MH202
Assembly, installation
Installation of the scenario programmer art. MH202 only requires connection to the
My Home Automation BUS.
In the case of logic expansion, connect the device to the private riser.
Install max 1 device per system.
Note: connect the E46ADCN power supply of the automation system to a doublepole switch.
230 Vac
Do not place devices that may generate electromagnetic interferences near
the Scenario Programmer.
NO
NO
T
E46ADCN
E46ADCN
Automation BUS
Automation BUS
MQ01013-b-EN
06/05/2015
3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF