Surveillance UPS
Surveillance UPS
The Surveillance UPS Series is an innovative and professional battery backup solution
for all your surveillance needs. You will be kept at ease knowing that during a power
outage, your CCTV camera and DVR/NVR equipment will continue running so you can
keep monitoring and recording your premises.
Applications: Provides battery backup, noise filtering, and surge protection for
12VDC/24VAC cameras, monitor and DVR/NVR systems.
12VDC / 24VAC Battery Power Backup for CCTV Cameras.
Automatic Voltage Regulation (AVR) for Wide Input Operation Voltage and Stable
Output Voltage.
12-13VDC Adjustable Output Voltage to Enhance Video Quality for Long-Distance
Cameras.
9/18 Ports Overload Protection (fuse optional) for CCTV Cameras.
Batteries are Hot Swappable (cameras, DVR, & monitors are always on).
Multi-LED Indicators for AC/DC Power Supply and UPS Power Status.
2 Amp Fuse or PTC (Break) Power Protection for High Power CCTV Cameras.
Two AC Outlets (NEMA 5-15R/110V or IEC/220V) with Battery Backup and Surge
Protection for DVR and Monitor.
Cameras Power Failure and AC Power Failure Notification through DVR/ NVR or
Alarm System.
SW1
IPS- SW-0 06 COD E:2
2012 -2-1 5
-4
432
3
SW1
IPS -SW -00 6 COD E:2
201 2-2 -15
4
1. Input Fuse
2. AC Input
3. AC Output
4. Fan (SUR-1218UPS/1518UPS): Operating on battery
mode and over heat.
-5
1
2
3
4
1.
When AC power fails, “NC” and “NO” connection will
provide a notification signal to the DVR/NVR or alarm system.
Majority of DVR/NVR systems also have e-mail alert features
to send notification of AC power failure.
2. UPS Bypass Switch
A) UPS Mode: Unit will go into backup mode if power fails.
B) AC Bypass Mode: Switch to this mode when batteries need to be changed or UPS is
abnormal. “AC Bypass” mode will continue to offer power to cameras, DVR and monitor.
3.
Long-distance cameras tend to lose voltage due to distance
from power source. Setting Vdc to a high setting will improve
long-distance camera picture quality.
321
4.
-6
1
5
6
7
8
5. 24VAC Port 15 ~ Port 18 (SUR-1218 UPS )
12VDC Port 15 ~ Port 18 (SUR-1518UPS)
6. Camrea Power Failure Notification Port
1. COM: NC
Normal Close
2. COM: NO
Normal Open
7. Model
Camera DC Power Failure
Notification Setting Dip Switch
SUR-0809UPS Port: 1-9
SUR-1218UPS
Port: 1-14
SUR-1518UPS
* Dip switch ports need to be switch to ON for the DC camera ports and DVR/NVR to receive
DC power failure notification.
* You can only turn dip switches ON with ports number you have your camera connected
to.
* You will get an wrong message if you switch ON with ports that have no camera connected.
8. 12VDC Port 1 ~ Port 9 (SUR-809UPS)
12VDC Port 1 ~ Port 14 (SUR-1218UPS)
12VDC Port 1 ~ Port 14 (SUR-1518UPS)
Model
12VDC
24VAC
SUR-809UPS
1A, Green LED, Port: 5-9
2A, Orange LED, Port: 1-4
N/A
SUR-1218UPS
1A, Green LED, Port: 5-14
2A, Orange LED, Port: 1-4
1A, Orange LED, Port: 15-18
SUR-1518UPS
1A, Green LED, Port: 5-18
2A, Orange LED, Port: 1-4
N/A
1) Connect all camera ports before connecting battery.
2) Connect battery before turning on UPS. (bypass switch must also be in “UPS mode”)
5.2 Turning off the unit: Push the button for 4 seconds to turn the UPS power off.The
UPS will turn off power completely within 10 seconds if there is a utility failure
during off mode. If the utility power is normal, the UPS will continue to charge
the battery.
When utility power is normal, please unplug the power cord if you want to turn
off the UPS completely.
5.3 DC start: During a blackout, push the button for 4 seconds to turn on the UPS
and enter into back-up mode. To turn off the power from UPS, please push the
button for 4 seconds. After turning off the UPS, please wait for 10 seconds if you
need to DC-start the UPS again.
-8
This unit is shipped from the factory with its internal battery fully charged, however,
some charge may be lost during shipping and the battery should be recharged prior
to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully
by leaving it plugged in for at least 10 hours.
Backup
Mode
STATUS
YELLOW LED
Battery normal
Load normal
2 flashes every
4 seconds
OFF
2 beeps every
8 seconds
No load (For green mode
function only)
One flash every
4 seconds
OFF
One beep every
8 seconds
Over load (will shut down
at 120% of full load)
2 flashes every
4 seconds
Over Temperature
32 flashes every
other 2 seconds
OFF
Depending on
load situation
O/P short circuit
32 flashes every
other 2 seconds
OFF
32 beeps every
other 2 seconds
Low battery
4 flashes every
second
OFF
4 beeps every
second
Over battery voltage
(For external battery)
8 flashes every
second
OFF
8 beeps every
second
Inphase lock (AC good,
PLL working)
OFF
STATUS
GREEN LED
RED LED
OFF
ON
4 flashes
every second
YELLOW LED
OFF
GREEN LED
BUZZER
Continuous beep
OFF
RED LED
BUZZER
AC
Battery full
OFF
Continuous ON
OFF
OFF
normal
Battery charge 70%~90%
OFF
One blink every 8 seconds
OFF
OFF
Battery charge 50%~70%
OFF
One blink every 4 seconds
OFF
OFF
Battery charge 30%~50%
OFF
One blink every 2 seconds
OFF
OFF
Battery charge 0%~30%
OFF
One blink every second
OFF
Over load(shut off at 120% of full load)
OFF
mode
OFF
Continuous
Beep★
ON
Note”★”: The buzzer will keep continuous beeping until the control button is pushed for one second.
STATUS
OFF
YELLOW LED
AC I/P disconnected
(UPS OFF completely)
mode
AC I/P normal (Batt. In charging)
UPS timer is set (Through RS232)
GREEN LED
OFF
RED LED
BUZZER
OFF
OFF
1 flash every
2 seconds
OFF
1 flash every
2 seconds
1 flash every
2 seconds
OFF
-9
-10
Press the ON/OFF/
TEST/SILENCE button
more than 1 second
Power cord loose
SUR-1218UPS
SUR-1518UPS
700VA/360W
700VA/360W
110/115/120VAC or 220/230/240VAC
80-145VAC or 154-280VAC
110/115/120VAC or 220/230/240VAC
Output
(24Vac/CCTV)
14A
14A
168W
168W
14 ports
18 ports
None
100W
None
None
4 ports
None
12V/7AH*1pc
(7AH*2 Option)
12V/7AH*2pcs
(9AH*2 Option)
12V/7AH*2pcs
(9AH*2 Option)
<6 hrs to 90%
35 ~50 minutes
<12 hrs to 90% capacity
55 ~75 minutes
60 ~80 minutes
LED status indicators for AC normal (Green), Back-up(Yellow),
UPS cut off(Red)
AC fuse and Electronic circuit(Line mode); Electronic
circuit(Back-up mode)
Overload/Short Protection
(Camera)
PTC 12VDC 2A*4 ports
12VDC 1A*5 ports
PTC 12VDC 2A*4 ports
12VDC 1A*10 ports PTC 12VDC 2A*4 ports
24VAC 2A*2 ports
12VDC 1A*14 ports
24VAC 1A*2 ports
DC Cold Start Function
22 lbs
24.5 lbs
24 lbs
ISO 9001-2008
*Battery backup time varies with equipment, configuration, battery age, temperature, etc. Turning off the monitor will
extend backup time.