TH PA22E - Acuity Brands

TH PA22E - Acuity Brands
Catalog
Number
Notes
FEATURES & SPECIFICATIONS
INTENDED USE — Use in mounting heights that require higher efficiencies, general horizontal/high vertical
illumination and premium contrast control. Ideal for light manufacturing areas, warehouse and retail aisles.
Certain airborne contaminants can diminish the integrity of acrylic and/or polycarbonate. Click
here for Acrylic-Polycarbonate Compatibility table for suitable uses.
CONSTRUCTION — Housing: Heavy-duty, die-cast aluminum halves. Ballast and electrical components
are heat-sinked and horizontally opposed. Integral splice box mounting flange ensures structural integrity.
Finish: Electrostatically-applied white polyester powder paint.
OPTICS — UV-stabilized, high-efficiency, high performance acrylic refractor yields high vertical footcandles
while maintaining low brightness. Upper collar is painted with white polyester powder paint. Optical assembly is fully adjustable and provides approximately 15% uplight. PA22E enclosed optical with an integral
flange utilizes a clear tempered-glass lens. Hinged and latched for easy maintenance. Meets UL lamp rupture
containment specifications. Coated lamps provide optimum performance.
ELECTRICAL — Ballast: Ballast: All ballasts are 100% factory tested. High Pressure Sodium: Constant wattage autotransformer; Metal Halide: D.O.E 2017 and EISA 2017 compliant Pulse Start, Super Constant Wattage
Autotransformer. All US shipments must order SCWA option.
CSA, NOM or INTL required for probe start shipments outside the US.
Socket: Vertically oriented mogul base PROTECTED EXCLUSIONARY base “PINK” socket with copper alloy nickel
plated screw shell and center contact. For use with “O” rated protected metal halide lamps only.
INSTALLATION — Pendant splice box: Removable cast-aluminum box slides on integral die-cast aluminum
housing mounting flange and mounts to 3/4” pendant conduit prior to ballast housing installation. Matching wire access cover accepts RELOC® modular wiring. Complete assembly meets or exceeds UL 50-pound
pull test.
Optical mounting: Adjustable reflector mounting brackets are progressively die-formed of 18-gauge
galvanized steel. For areas where reflectors are subject to impact (gymnasiums, etc.) add FWG (full wire
guard) accessory.
LISTINGS — UL Listed -30°C to 40°C ambient operations and damp locations. Listed and labeled to comply
with Canadian standards. NOM certified (see Options).
WARRANTY — 1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Note: Actual performance may differ as a result of end-user environment and application.
Specifications subject to change without notice.
ORDERING INFORMATION
Type
Lensed High Bay Industrial Lighting
TH PA22E
ACRYLIC OPTICAL
PROTECTED METAL HALIDE
175W - 250W
HIGH PRESSURE SODIUM
250W - 400W
16' to 25' mounting
Specifications
Overall height: 22-1/2 to 25-3/4 (57.2 to 65.4)
Width:
22-3/8 (56.8)
All dimensions are inches (centimeters) unless otherwise indicated.
Example: TH 250MP PA22E 120 SCWA
Lead times will vary depending on options selected. Consult with your sales representative.
TH
PA22E
Series
Wattage
TH
Metal halide
175MP 1,2,3
200MP 3
25OMP 2
Protected metal halide – Title 20
2OOMP
3,4
High pressure sodium
250S
400S
Reflector
Voltage
Ballast
PA22E
120
208 5
240 5,6,7
277
347
480 5
TB 8
(blank)
CWI
Standard magnetic ballast9
Constant wattage isolated
Note: For shipments to US Territories, SCWA must be specified to comply with EISA.
SCWA
RLB
Super constant wattage autotransformer
Regulated lag ballast 9
Options
Shipped installed in fixture
SF
Single fuse (120, 277, 347V) 10,11
DF
Double fuse (208, 240, 480V) 10,11
EC
Emergency circuit 11,12,13
QRS Quartz restrike system 11,12,13
QRSTD
TOB
LCPP
LC3P
HC3P
QRS time delay 11,12,13
Through-wire outlet box
Loop, cord, plug requires TPH, PPH 10
Loop, 3' cord, 15A NEMA twist-lock plug 10,14
Hook, 3' cord, 15A NEMA twist-lock plug 10,14
Accessories: Order as separate catalog number.
SCK
HKF
LPF
TMB
SMB
HKM
60" safety chain kit
Fixture hook female
Fixture loop female
Twin-mounting bar (consult factory)
Single mounting bar (consult factory)
Fixture hook male
HKMG
LPM
LPMG
TPH
PPH
FWG
Grommeted fixture hook male
Fixture loop male
Grommeted fixture loop male
Through-wire power hook
Pendant power hook
Full wire guard
LOCS
HOCS
LOCU
HOCU
TR
Loop, 5' white cord, RELOC OCS 10,14
Hook, 5' white cord, RELOC OCS 10,14
Loop, 5' white cord, RELOC OCU 8,10,14,15
Hook, 5' white cord, RELOC OCU 8,10,14,15
Remote ballast 16
Notes
1 Coated lamp not available; may experience glare with
clear lamp.
2 In order to comply with California Title 20 regulations
for metal halide fixtures, these metal halide wattages
must be ordered with KW1S option for sale to California.
3 Not available with 480V.
4 These wattages comply with California Title 20.
5 Requires CWI or RLB option in Canada for MH.
6 Requires CWI or MRB option in Canada for HPS.
7 220V and 240V 50Hz and 60Hz ballasts available for use
with US metal halide lamps.
8 Optional multi-tap ballast (120, 208, 240, 277V). For
voltage specific options specify tap position (TB1=120V,
TB2=208V, TB3=240V, TB4=277V).
RC3NP
KW1S
CSA
NOM
INTL
TR with prewired 3' cord 10
KiloWatch II with integral sensor
Listed and labeled to comply with
Canadian standards
NOM certified (Consult factory)
International shipments
9
10
11
12
13
Available for shipment outside the U.S. only.
Must specify voltage or tap position.
Option is not field-installable; must be factory-installed.
Lamp not included.
See Product Selection Guide (QRS Lamp Wattage Table)
for maximum lamp wattage.
14 20A standard 480V.
15 May be ordered with 10', 15' and 20' cords. For black
cord, specify BK (i.e. HOCSBK).
16 For specific ordering information, see Product Selection
Guide.
INDUSTRIALTH-PA22E
TH PA22E High Bay
PHOTOMETRICS
See www.lithonia.com.
ELECTRICAL CHARACTERISTICS
Energy: (Calculated in accordance with NEMA Standards LE-5)
Line current
(Amps)
Wattage/
Ballast
250 CWA
Peak-lead
Autotransformer
250 CWA Constant wattage
isolated
Primary
voltage
Start/
Operating
Primary
dropout
voltage
120
208
240
277
480
120
208
240
2.20/2.60
1.30/1.50
1.10/1.30
1.00/1.12
.60/.65
.90/2.66
.50/1.54
.45/1.33
60
104
120
138
240
60
105
120
Input
watts
Power
factor %
Regulation line
V = Lamp
lumens
295
90+
±10% = ±10%
295
90+
±10% = ±10%
LER.HID
Annual
energy cost
Lamp description
Lamp
lumens
Ballast
factor
Input
watts
60.2
$3.99
MH250C/U
20,500
1
295
Tested to current IES and NEMA standards under stabilized laboratory conditions. Various
operating factors can cause differences between laboratory data and actual field measurements. Dimensions and specifications on this sheet are based on the most current available
data and are subject to change without notice.
TH-PA22E
INDUSTRIAL: One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4963 Fax: 770-981-8191 www.lithonia.com
© 1992-2017 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/22/17
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement