Nuisance Alarms Filter Alarm Verification
To help prevent false alarm causing
a full evacuation, any smoke
detector can be set to alarm
verification mode with a time
delay of between 30 seconds and 3
minutes 45 seconds. Should any of
these detectors go into alarm then
only the detector’s LEDs and sound/
flasher base (if connected) will
activate. Should the alarm not be
cleared with this time delay then a
common alarm will occur.
Installation &
Commissioning
In addition to the benefits already
listed, once the panel has been
connected a ‘Device Count
Verification’ feature will confirm the
number and type of every device.
This can then be checked against
the system specification.
The Simplicity Plus is the ideal introduction to
the world of addressable fire alarm panels.
As its name suggests, it has been designed with ease
of use in mind, using pre-programmed values for its
programming options. The installer simply needs to
configure the loop and enter text labels via the built in
keypad (optional).
The Simplicity Plus has user definable zones, option
for zonal or common alarm operation, options for
I/O operation, alarm verification and user selectable
languages.
It can be connected to an RS232 desktop printer for real
time event log printing (Epson LQ300+ recommended)
and it can also drive a serial repeater model AD-REP/M
(Part No. 37-157).
Standards
The Simplicity Plus fire alarm
control panel has been designed to
meet the full requirements of EN54
part 2 and EN54 part 4.
Cable Break Protection
In the event of a cable break, the
panel will report the break. The
devices after the break will be lost,
but will be listed one-by-one on
the panel display to help locate the
break.
System Monitoring
Since every device is monitored
constantly and communicates with
the panel at a maximum interval
of 4 seconds, any malfunction in
any device will be reported by the
panel. This of course will include
the exact location of the device.
Zeta Alarm Watch
Features
One or Two loop addressable fire alarm panel
(64, 126 or 252 device capacity)
Using the Zeta alarm watch software, multiple panels
can be monitored from a central PC. The panels can be
grouped by company to give a structured display on the
PC.
Certified to EN54 parts 2 & 4
User definable zones
Option for zonal or common alarm operation
Options for I/O operation
Alarm verification (help prevent false alarms)
User selectable languages
Set of changeover relay contacts for fault
condition
Set of changeover relay contacts for fire
condition
2,048 event log (fire & fault)
Zone or device disablement
One man test mode
Plug & play, no need for any special tools or
laptop for commissioning
Fully integrated keypad
All associated devices are loop powered
Soft Addressing
The MKII Handheld Programmer (MKIITOOL) is designed to compliment
all MKII devices and to assist the
comissioning engineer on site.
Smoke and heat detectors can be
tested when plugged on the programmer and alarm LED’s
can be verified prior to installation.
The unit will softly address all devices without using the
incorporated dip-switch on the field devices.
The MKII Programmer can re-program the opto-heat
detectors to either heat or smoke detector.
Zonal Addressing
All devices are assigned to a specific zone based on their address.
This removes a programming step and helps to streamline the
commissioning process. The following table outlines which
addresses fall in which zones.
Zone
SP-64/M
SP-126/M
1: Address 1 - 16
SP-252/M
Zone 1
1: Address 1 - 16
Zone 2
1: Address 17 - 32 1: Address 17 - 32
1: Address 33 – 64
1: Address 1 - 32
Zone 3
1: Address 33 - 48 1: Address 33 - 48
1: Address 65 – 96
1: Address 97 – 126
Zone 4
1: Address 49 - 64 1: Address 49 - 64
Zone 5
1: Address 65 - 80
2: Address 1 – 32
Zone 6
1: Address 81 - 96
2: Address 33 – 64
Zone 7
1: Address 97 - 112
2: Address 65 – 96
Zone 8
1: Address 113 - 126 2: Address 97 - 126
The Simplicity panel can transmit
the following information
Device alarm (including loop & address
information)
Device fault (including loop & address
information)
Features
Addressable repeater panel (display only, no
controls)
Complies fully to EN54 parts 2 & 4
Panel reset
Model
AD-REP/M
Loop reconfigured
Part No.
37-157
Loop wiring fault
Supply Voltage
20 – 30 V DC
Power supply fault
System Voltage
29V DC (Nominal)
Earth fault
Connections
Supply + ,Supply –, Data +, Data -
Operating Temperature
-0°C to 50°C
Enclosure Size (mm)
(W) 375 x (H) 335 x (D) 75mm
Weight
1 KG
Clock reset
Evacuation started
Simplicity Plus
Addressble Fire Alarm System
Device Order Codes
Fyreye MKII Addressable Detectors (DIFT Approved)
MKII-AOP
80-210
Fyreye MKII Addressable Optical Smoke Detector
MKII-AHR
80-212
Fyreye MKII Addressable Rate of Rise Heat Detector
MKII-AHF
80-214
Fyreye MKII Addressable Fixed Heat Detector
MKII-AOH
80-216
Fyreye MKII Addressable Combined Smoke & Heat Detector
Fyreye MKII Addressable Detector Bases
MKII-CB
80-220
Fyreye MKII Common Base
MKII-CB/D
80-221
Fyreye MKII Deep Base
MKII-IB
80-0908
Fyreye MKII Isolator Base
MKII-ISO
80-0918
Fyreye MKII Stand-Alone Isolator
Fyreye MKII Handheld Programming Tool
MKII-TOOL
48-004
Fyreye MKII Handheld Programming Tool-
Fyreye MKII Sandwich Sounder/Flasher
MKII-SSB
80-224
MKII Sandwich Sounder (no address required)
MKII-SSFB
80-225
MKII Sandwich Sounder/Flasher (no address required)
Zeta Addressable Manual Call Points
ZT-CP3/AD
43-621
Zeta Addressable Surface Mount Manual Call Point
CP3-FMB
43-635
Zeta CP3 Call Point Flush Mount Bezel
CP3-CV
43-636
Zeta CP3 Call Point Cover
CP3-KEY
43-637
Zeta CP3 Call Reset Key
ZT-CP3/AD/WP
43-622
Zeta Addressable Weatherproof Manual Call Point (Surface Mount Only)
Zeta Xtratone Addressable Sounder, Flasher & Combined Sounder Flasher (MKII)
MKII-AXT/R
42-610
Zeta Addressable Xtratone Sounder, Red, Fyreye II Protocol
MKII-AXT/W
42-611
Zeta Addressable Xtratone Sounder, White, Fyreye II Protocol
MKII-AXTSF/R
42-612
Zeta Addressable Xtratone Sounder Flasher, Red, Fyreye II Protocol
MKII-AXTF/R
42-613
Zeta Addressable Xtratone Flasher, Red, Fyreye II Protocol
Zeta Miditone Addressable Sounders and Combined Sounder & Flasher (MKII)
MKII-AMD/8R
42-600
Zeta Miditone Addressable Sounder (Red)
MKII-AMD/8W
42-601
Zeta Miditone Addressable Sounder (White)
MKII-AMSF/R
42-602
Zeta Miditone Addressable Combined Sounder & Flasher (Red)
MKII-AMF/R
42-603
Zeta Miditone Addressable Flasher Only (Red)
Zeta Maxitone Addressable Sounders and Combined Sounder & Flasher
MKII-AMT/R
42-620
Zeta Maxitone Addressable Sounder (Red)
MKII-AMT/W
42-621
Zeta Maxitone Addressable Sounder (White)
MKII-AMTSF/R
42-622
Zeta Maxitone Addressable Combined Sounder & Flasher (Red)
MKII-AMTF/R
42-623
Zeta Maxitone Addressable Flasher Only
Fyreye MKII Addressable Interfaces
ZAI-MI
48-101
Fyreye MKII Addressable Input Module with S/C Isolator (loop powered)
ZAIO-MI
48-108
Fyreye MKII Addressable Input/Output Module with S/C Isolator (loop powered)
ZASC-MI
48-112
Fyreye MKII Addressable Sounder Circuit Controller with S/C Isolator (need ext PSU)
ZAZM-MI
48-117
Fyreye MKII Addressable Zone Monitoring Unit with S/C Isolator (loop powered)
Other Zeta Products
25 Years of Manufacturing Excellence
INFINITY
The 2 Wire Fire Detection
System for Professionals
25 Years of Manufacturing Excellence
25 Years of Manufacturing Excellence
Premier Quatro
Premier M Plus & Infinity 8
007
Assessed to ISO 9001: 2008
Certificate number 330
Conventional Fire
Alarm Systems
007
Assessed to ISO 9001: 2008
Certificate number 330
Addressable Fire
Alarm System
007
Assessed to ISO 9001: 2008
Certificate number 330
25 Years of Manufacturing Excellence
Gas Sense
Gas Detection System
Premier EVACS 16
Voice Alarm System
eclipse
Security Alarm
Systems
Available now from:
007
Assessed to ISO 9001: 2008
Certificate number 330
Tel: +44 (0) 1792 455 175
Fax: +44 (0) 1792 455 176
Email:[email protected]
Web: www.zetaalarmsystems.com
Detection House
72-78 Morfa Road
Swansea
SA1 2EN
United Kingdom
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement