The Sealed Battery Specialists
®
Small Sealed AGM Batteries
The Sealed Battery Specialists
4 V B AT T E R I E S
Nominal Capacity (AH)
Model
ES4.5-4
ES9-4
Weight
Terminal
Dimensions (Inch)
Nominal
Voltage (V)
20hr Rate
F.V. (1.75V/cell)
10hr Rate
F.V. (1.75V/cell)
5hr Rate
F.V. (1.75V/cell)
g.
lbs.
Type
Position
L
W
H
TH
4
4
4.5
9
4.275
8.55
3.825
7.65
652
1187
1.43
2.61
F2
F2
6
3
1.89
3.98
2.05
1.73
3.70
3.74
3.94
4.02
6 V B AT T E R I E S
Nominal Capacity (AH)
Model
ES1.2-6
ES3-6
ES3-6H
ES3.8-6
ES4-6
ES7-6
ES8.2-6 S
ES12-6
ES12-6 RND
ES12-6 SQR
ES13-6
ES42-6
Weight
Nominal
Voltage (V)
20hr Rate
F.V. (1.75V/cell)
10hr Rate
F.V. (1.75V/cell)
5hr Rate
F.V. (1.75V/cell)
g.
6
6
6
6
6
6
6
6
6
6
6
6
1.2
3
2.8
3.8
4.5
7
9
12
13
13
13
42
1.14
2.85
2.66
3.61
4.275
6.65
8.55
11.4
12.35
12.35
12.35
39.9
1.00
2.55
2.4
3.23
3.825
5.95
7.65
10.2
11.05
11.05
11.05
35.7
308
692
569
735
908
1312
1680
1990
2179
2179
2179
6180
lbs.
Terminal
Type
0.68
F1
1.52
F1
1.25
F1
1.62
F1
2.00
F1
2.89
F1
3.70
F1
4.38 F1, F2
4.79 WIRE(wi50-63)
4.79 WIRE(wi50-54)
4.79 F1-, F2+
13.60
F2
Dimensions (Inch)
Position
L
W
H
TH
2
2
1
1
1
2
8
2
7
7
18
14
3.82
5.28
2.60
2.60
2.76
5.94
3.88
5.94
4.25
4.25
4.25
6.38
0.98
1.34
1.30
1.30
1.85
1.34
2.20
1.97
2.76
2.76
2.76
3.46
2.05
2.32
3.82
4.65
3.98
3.70
4.65
3.70
5.51
5.51
5.51
6.42
2.24
2.56
4.09
4.96
4.21
3.94
4.65
3.90
5.51
5.51
5.51
6.69
1 2 V B AT T E R I E S
Nominal Capacity (AH)
Model
ES0.8-12
ES1.2-12
ES1.9-12
ES2-12SLM
ES2.3-12V
ES2.9-12
ES3-12
ES3-12R
ES5-12*
ES7-12*
ES9-12
ES10-12S
ES12-12
ES17-12
ES20-12C
ES26-12
ES33-12
ES40-12
ES40-12HR
ES50-12
Weight
Nominal
Voltage (V)
20hr Rate
F.V. (1.75V/cell)
10hr Rate
F.V. (1.75V/cell)
5hr Rate
F.V. (1.75V/cell)
g.
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
0.7
1.2
2.3
1.8
2.1
2.9
3
2.8
5
7.2
8.5
10
12
18
20
26
34
45
37
50
0.665
1.14
2.185
1.7
1.9
2.755
2.85
2.66
4.75
6.84
8.08
9.5
11.4
17.1
19
24.7
32.3
42.75
35.15
47.5
0.595
1.02
1.96
1.53
1.785
2.465
2.55
2.4
4.25
6.12
7.23
8.5
10.2
15.3
17.0
22.1
28.9
38.25
31.45
42.5
370
596
1060
762
682
1263
1370
1160
1830
2678
2980
3335
3820
6283
6000
9327
10850
14109
14640
13837
*Available In Flame Retardant Case.
lbs.
Terminal
Type
0.82 WIRE(wi50-10)
1.31
F1
2.34
F1
1.68
F1
1.50
F13
2.79
F1
3.02
F1
2.55
F1
4.04 F1, F2
5.91 F1, F2
6.38
F2
7.34
F2
8.40
F2
13.82 F2, F3
13.20
F3
20.52 F2, F3
23.92
F4
31.04
F4
32.28
F9
30.44
F8
Dimensions (Inch)
Position
L
W
H
TH
15
4
2
12
16
13
4
2
3
5
5
5
5
17
10
17
9
10
11
11
3.78
3.82
7.01
5.91
7.17
3.11
5.28
5.24
3.54
5.94
5.94
5.94
5.94
7.13
7.13
6.54
7.76
7.80
9.84
7.80
0.98
1.69
1.34
0.79
0.91
2.20
2.64
1.30
2.76
2.56
2.56
2.56
3.86
2.99
2.99
6.89
5.16
6.54
3.84
6.54
2.44
2.09
2.36
3.54
2.40
3.90
2.34
3.82
4.00
3.70
3.70
4.41
3.66
6.57
6.54
4.92
6.26
6.73
7.95
6.73
2.44
2.32
2.60
3.54
2.40
4.21
2.58
4.09
4.25
4.02
4.02
4.65
3.86
6.57
6.54
4.92
7.09
6.73
7.95
6.73
AGM SPECIFICATIONS
IMPORTANT CHARGING INSTRUCTIONS:
BENEFITS
Dimensions (mm)
L
W
H
TH
Maximum Discharge
Current (A) for 5 sec.
48
101
52
44
94
95
100
102
180
360
Maximum Charge
Current (A)
1.35
2.70
WARRANTY VOID IF OPENED OR IMPROPERLY CHARGED.
Constant under or overcharging will damage any battery and
shorten its life! Use a good constant potential, voltage-regulated
charger. Do not charge in a sealed container.
• Maintenance-Free
• Valve Regulated
• Rugged, Compact Design
Charging Voltage for 4V Batteries at 68ºF
Cycle Use: 4.8-5.0V
Standby Use: 4.5-4.6V
Charging Voltage for 6V Batteries at 68ºF
Cycle Use: 7.2-7.5V
Standby Use: 6.75-6.9V
Charging Voltage for 12V Batteries at 68ºF
Cycle Use: 14.4-15.0V Standby Use: 13.5-13.8V
• Multiple Applications
• Float or Cycle Use
• Low Self-Discharge
• Lead Calcium Construction
• Absorbed Glass Mat
NON-SPILLABLE by DOT (Department of Transportation), ICAO
(International Commercial Airline Organization), and IATA
(International Airline Transport Association) definitions.
• Tank Formed Plates
Dimensions (mm)
W
H
TH
Maximum Discharge
Current (A) for 5 sec.
Maximum Charge
Current (A)
97
134
66
66
70
151
98
151
108
108
108
162
25
34
33
33
47
34
56
50
70
70
70
88
52
59
97
118
101
94
118
94
140
140
140
163
57
65
104
126
107
100
118
99
140
140
140
170
48
120
112
152
180
280
360
240
520
520
520
1680
0.36
0.90
0.84
1.14
1.35
2.10
2.70
3.60
3.90
3.90
3.90
12.60
EXTERIOR
DIMENSIONS
ISO 9001
ISO 14001
MH16982
AMBIENT TEMPERATURE
Charge
L
Discharge Storage
0ºC
(32ºF)
-15ºC
(5ºF)
-15ºC
(5ºF)
40ºC
(104ºF)
50ºC
(122ºF)
40ºC
(104ºF)
W
H
TH
L
TERMINAL POSITIONS
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Dimensions (mm)
TERMINAL TYPE MM (INCH)
F3
F2
F4
+0.3
12
- 0.5
16
2
7.2
(M5 Bolt)
F8
F13
F9
M6
M6
6.5
F1
17
0.21
0.36
0.69
0.54
0.63
0.87
0.90
0.84
1.50
2.16
2.55
3.00
3.60
5.40
6.00
7.80
10.20
13.50
11.10
15.00
WIRE
WIRE
RND Wi50-63
SQR Wi50-54
16.9
WIRE
1 2
28
48
92
72
20
116
120
112
200
288
340
400
480
720
800
1040
1360
1800
1480
1000
5.5 +0.5
-0
62
59
66
90
61
107
66
104
108
102
102
118
98
167
166
125
180
171
202
171
15
62
53
60
90
61
99
60
97
101
94
94
112
93
167
166
125
159
171
202
171
5
25
43
34
21
23
56
67
33
70
65
65
65
98
76
76
175
131
166
98
166
11
96
97
178
150
182
79
134
133
90
151
151
151
151
181
181
166
197
198
250
198
10
Maximum Charge
Current (A)
6.35
(0.25)
Maximum Discharge
Current (A) for 5 sec.
0.9
(0.03)
TH
11
H
4.75
(0.187)
W
0.8
(0.03)
L
RND Wi50-10
C H A R A C T E R I S T I C S O F M K A G M B AT T E R I E S
(v)
For 4v
Battery
4.4
(v)
(v)
For 6v For 12v
Battery Battery
6.5
13.0
Discharge Time vs. Discharge Current (25ºC)
Effect of Temperature on Capacity
120
6.0
12.0
3.6
5.5
11.0
3.4
5.0
10.0
3.0
4.5
9.0
2.6
4.0
8.0
1CA
3CA 2CA
0.6CA
Retention Capacity %
20ºC (68ºF)
4.0
0.1CA 0.05CA
0.4CA 0.2CA
100
0.05CA
0.1CA
80
0.25CA
0.6CA
60
1CA
2CA
40
20
1
2
4
6 8 10
20
40 60
2
4
Minutes
6 8 10
0
20
-20
-4
Hours
Discharge Time
(%)
100
-10
14
0
32
10
20
30
40
50
68
86
104
Ambient Temperature
50
122
[ºC]
[ºF]
Life Characteristics of Cyclic Use
Charge Retention Characteristics
(1) Discharge: 0.17CA for 3hr
(2) Charge: 0.1CA for 9 hr
(3) End of Life Discharge Voltage: 1.65Vpc
(4) Temperature: 25ºC
120
75
10ºC (50ºF)
Capacity %
Charge Retention (%)
0ºC (32ºF)
20ºC (68ºF)
50
40ºC (104ºF)
30ºC (86ºF)
25
100
80
60
Discharge Discharge
Depth 100% Depth 80%
Discharge
Depth 50%
Discharge
Depth 30%
40
20
0
3
6
9
12
15
0
18
200
400
Retention Period (Months)
600
800
1000
Number of Cycles (times)
1200
Trickle Charge Lifespan Characteristics
10
Trickle Charge Lifespan (Years)
Life Characteristics of Standby Use
Retention Capacity (%)
120
100
80
60
Floating charging voltage: 2.25-2.30 V/cell
Ambient temperature: 20ºC (68ºF)
40
20
0
1
2
Life (Years)
5
Trickle Charging Voltage
2.25 to 2.30 V/cell
2
0.5
3
Ambient Temperature
20
68
30
86
40
104
50
122
[ºC]
[ºF]
Y O U R PA RT N E R I N P O W E R
MK Battery is one of the largest sealed lead acid battery suppliers worldwide due to our
total commitment to the following core principles:
Products
Service
Customer Care
MK Battery supplies only the highest quality batteries (gel, AGM and flooded deep cycle)
that are specifically designed for our customers’ many, varied applications including
broadband communications, UPS (uninterruptible power supplies), power wheelchairs,
telephony (valve-regulated stationary), solar, marine and electronics.
MK Battery ships fresh inventory fast, often within 24 hours, from a stock of more than
100,000 batteries in multiple distribution centers throughout the world and assists our
customers with proper spent battery disposal. (Please note that violation of hazardous waste
disposal laws can place heavy penalties on offenders).
MK Battery is genuinely concerned for our customers’ well-being as a long-term partner...
not just a supplier. MK Battery listens to our customers and delivers what you want,
when you need it.
®
MK Battery International: UK: Unit 6B, Vernon Ct., Henson Way, Telford Way Industrial Estate, Kettering, Northamptonshire, England, NN16 8PX
Tel : +44 (0)1536 484009 • Fax : +44 (0)1536 484702 • Website: www.mkbattery.com • Email: [email protected]
MK Battery International: Holland: Rondweg 7, 6515 AS, Nijmegen, The Netherlands
Tel : +31 24 348 3223 • Fax : +31 24 348 3839 • Website: www.mkbattery.com • Email: [email protected]
All data subject to change without notice. No part of this document may be copied or reproduced, electronically or mechanically, without written permission from the company. ©2009 MK Battery
LIT-SS1004MKBI 10/09
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement