bridge watch alarm system

bridge watch alarm system
9986371 Manualforside BW800:1
18-05-2009
12:48
Side 1
BRIDGE WATCH
ALARM SYSTEM
BW-800
NE
W!
Bridge Watch BW-800
ALARM STAGE
min.
SELECT
MODE
BRIDGE ALARM 1
BRIDGE ALARM 2
MANUAL
-
AUTO
set
+
CAPTAIN’S ALARM
STAFF ALARM
Bridge Watch ACTIVE
Bridge Watch STANDBY
RESET
ON
Bridge Watch MALFUNCTION
TIMER and BRIDGE WATCH MODE
can be operated within 30 sec. after key is switched to ON
OFF
Uni-Safe Electronics A/S
Emergency call: press 2 sec.
(to cancel call: press 2 sec. again)
www.unielec.dk
New regulations from IMO’s Maritime Safety Committee (MSC) will require carriage of a Bridge
Navigational Watch Alarm System (BNWAS) complying with IMO performance standards. For
existing ships, the equipment should be installed in connection with the first survey after the
following deadlines:
Existing passenger ships and ships over 3,000 GT: 1 July 2012.
Existing ships over 500 GT: 1 July 2013.
Existing ships over 150 GT: 1 July 2014.
New ships over 150 GT and all new passenger ships constructed after 1 July 2011 shall be
equipped with a Bridge Navigational Watch Alarm System.
Competitive prices
User-friendly, small and easy to install
Automatic dimmer control
Emergency call facility
Timer display
Motion sensor with infrared and microwave detection
Visual alarm: Reset unit is flashing
Output for motion sensor secured against short circuit
Alarm signal increases in volume
Y
Produced and developed in Denmark
9986371 Manualforside BW800:1
18-05-2009
12:48
Side 2
Specifications BW-800
Complies with following standards:
IMO A.694(17)
IMO A.830(19)
IMO MSC. 128(75)
IEC 62616
IEC 60945
IEC 62288
IEC 61162
Dimension:
BW-801 reset unit:
Front: 50 mm x 50 mm
Mains supply:
24 Vdc
BW-802 alarm unit:
Front: 50 mm x 77 mm
Mains power:
Mains supply must be secured against overcurrent with an
external fuse. Max. 500 mA
Display:
2 LED displays (2 digits)
Timer interval:
3-12 min.
Relay contacts:
Max. 10 A / 24 Vdc.
Relay contacts must be secured against overcurrent with
external fuses
Battery backup:
Battery backup supply must be secured against
overcurrent with an external fuse. Max. 500 mA.
Battery backup must be able to supply BW-800
for a period of 6 hours (min. 3 Ah battery backup)
Protection:
IP 65
BW-800:
Front: 160 mm x 100 mm
Cut out: 140 mm x 95 mm
Depth: 50 mm
The purpose of a bridge navigational watch alarm system (BNWAS) is to monitor bridge activity and detect operator
disability which could lead to marine accidents. The system monitors the awareness of the Officer of the Watch
(OOW) and automatically alerts the Captain or another qualified OOW if for any reason the OOW becomes
incapable of performing the OOW's duties. This purpose is achieved by a series of indications and alarms to alert
first the OOW and, if he is not responding, then to alert the Captain or another qualified OOW. Additionally, the
BNWAS may provide the OOW with a means of calling for immediate assistance if required. The BNWAS should be
operational whenever the ship's heading or track control system is engaged, unless inhibited by the Captain.
Activity input from
other equipment:
Radar, ECDIS,
VHF....
Malfunction output
to central alarm
panel if fitted
Bridge Watch BW-800
ALARM STAGE
min.
SELECT
MODE
BRIDGE ALARM 1
BRIDGE ALARM 2
MANUAL
-
AUTO
set
+
CAPTAIN’S ALARM
STAFF ALARM
Input from ships
heading or track
control system
Main power 24 Vdc
Bridge Watch ACTIVE
RESET
ON
Bridge Watch STANDBY
Bridge Watch MALFUNCTION
TIMER and BRIDGE WATCH MODE
can be operated within 30 sec. after key is switched to ON
VDR interface
output
OFF
Uni-Safe Electronics A/S
Emergency call: press 2 sec.
(to cancel call: press 2 sec. again)
Battery backup
power 24 Vdc
www.unielec.dk
BW-802
BW-801
BW-802
BW-802
Bridge Watch
Bridge Watch
Bridge Watch
ASSISTANCE
TO BRIDGE
NEEDED
ASSISTANCE
TO BRIDGE
NEEDED
ASSISTANCE
TO BRIDGE
NEEDED
Bridge Watch
RESET
Press button
to reset
Emergency call: press 2 sec.
(to cancel call: press 2 sec. again)
Uni-Safe Electronics A/S
Motion Sensor
Uni-Safe Electronics A/S
www.unielec.dk
Reset unit with visual alarm
TE
www.unielec.dk
Alarm 1: Bridge
Activated 15 sec.after
visual alarm
Uni-Safe Electronics A/S
www.unielec.dk
Alarm 2: Captain´s quarters
Activated 15 sec. after
alarm 1
Uni-Safe Electronics A/S
www.unielec.dk
Alarm 3: Crew area
Activated 60-180 sec. after
alarm 2
Visit us ! - www.bnwasturkey.com
TEL : +90 216 425 77 00
FAX : +90 216 425 77 88
www.yddo.com.tr
www.unielec.dk
BRIDGE WATCH MODE