installation and maintenance instructions for two handle kitchen

installation and maintenance instructions for two handle kitchen
INSTALLATION AND MAINTENANCE
INSTRUCTIONS FOR TWO HANDLE
KITCHEN FAUCETS
MAINTENANCE AND CARE INSTRUCTIONS
Olympia products are designed and engineered under strict quality standards. Regular and proper care of our
products will ensure years of trouble free service. To clean, simply wipe with a damp, soft cloth. Do not use
abrasive or harsh cleaners as they may result in finish damage. Regularly remove the aerator and clean any
debris inside it.
TROUBLE SHOOTING
A.
B.
C.
D.
If water leaks from the spout outlet:
If faucet has low flow:
If handles do not stop turning:
If spray does not function properly:
THIS PRODUCT MEETS THE FOLLOWING STANDARDS: ASME A112.18.1 ~ ANSI
A117.1 ~ ANSI / NSF 61, SECTION 9 ~ UPC / IAPMO LISTED / ADA COMPLIANT ~
COMPLIES WITH CALIFORNIA LEAD PLUMBING LAW
1.
Shut off both hot and cold water supplies.
2.
Remove handles (A1-A4), bonnet nuts (B), and cartridges (C).
3.
Check and replace springs and seats (D).
4.
Reassemble handles (A1-A4), bonnet nuts (B), and cartridges
(C).
5.
If seepage still occurs, replace cartridges (C).
#K-5120
Acrylic Handles ~ Less Spray
1.
Repeat Trouble Shooting “B”
2.
Repeat Trouble Shooting “A” and clean any debris trapped in
the seats and springs.
#K-5130*
Mini Blade Handles ~ Less Spray
#K-5121
Acrylic Handles ~ With Spray
1.
Shut off both hot and cold water supplies.
#K-5150*
ADA Wrist Blade Handles
2.
Remove handles (A1-A4) and bonnet nuts (B).
#K-5160*
Lever Handles ~ Less Spray
3.
Check stops on cartridges (C) or inside handles (A1-A6) for
damages.
#K-5161*
Lever Handles ~ With Spray
4.
Replace necessary parts.
1.
Shut off both hot and cold water supplies.
2.
Remove spray head (N), clean debris, and reassemble.
3.
Remove cap (I) and spout (J) and clean diverter piston (M).
4.
Reassemble cap (I) and spout (J).
PRODUCT NUMBERS
ADA*
OLYMPIA FAUCETS, INC. LIMITED LIFETIME WARRANTY *
Olympia Faucets, Inc. warrants its products to the original consumer purchaser to be free from defects in material
and workmanship as long as the consumer purchaser owns it. Dated proof of purchase must accompany all warranty claims. PVD finishes carry a lifetime warranty in residential service.
Olympia Faucets, Inc. will replace, free of charge, to the original consumer purchaser, any and all parts that
prove defective under normal installation, use, and service. Damage as a result of misuse, abuse, accident, or
improper installation, will consequentially void this warranty. Replacement parts can be obtained from your local
dealer or directly from Olympia Faucets. Olympia Faucets, Inc. recommends using a certified plumber for all
faucet installation and repair.
This warranty is limited to replacement of defective parts only. Incidental and consequential damages, labor
charges, repair, or replacement costs are expressly excluded. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives
you specific legal rights, as you may have other rights of which vary from state to state.
Installation or maintenance and cleaning must be in compliance with instructions furnished with every Olympia
product. If you find a problem with your product, please immediately contact your nearest Olympia Faucets, Inc.
dealer or sales representative.
* 2 year limited warranty on commercial and multi-family projects.
Olympia Faucets, Inc. © 2009
INSTALLATION INSTRUCTIONS
Tools you will need:
Thank you for purchasing this quality product. Olympia products are rigorously tested to provide long service
under normal conditions. Prior to installation, familiarize yourself with this parts diagram. Make sure that you have
all of the illustrated parts for your Olympia product before installation.
•
Plumbers Putty
•
Teflon Tape
•
Screwdriver
•
Flexible Supply Lines
•
Pipe Wrench
•
Adjustable Wrench
•
Basin Wrench
•
Soft Cloth
FAUCET INSTALLATION:
1.
Carefully shut off both hot and cold water supplies from under the sink. Plug the sink drain with
a soft cloth to prevent intrusion of debris or the loss of any faucet parts. If this installation is for a
replacement, carefully remove the existing faucet and clean the entire surface of the sink mounting
holes.
2.
Apply adequate Plumbers putty along the boundary of the bottom of the base gasket (F).
3.
Gently align the faucet with the sink mounting holes and place the faucet on the sink. Use caution to
lead brass waterways through the sink mounting holes.
4.
Thread friction washers (G) and mounting locknuts (G) along the brass waterways. Carefully hand
tighten the mounting locknuts. CAUTION: Do not overtighten.
5.
Connect both hot (LEFT INLET) and cold (RIGHT INLET) waterways to water supply lines. NOTE:
If additional adapters or supply lines are required, they may be purchased from the same location
where this faucet was purchased. Use with Teflon tape when attaching supply lines to waterways.
SPRAY ASSEMBLY INSTALLATION:
ITEM #
DESCRIPTION
A1
OP-190003C,H
Acrylic Handle Cold,Hot
A2
OP-190004C,H
Mini Blade Handle Cold, Hot
A3
OP-190005C,H
Wrist Blade Handle Cold, Hot
A4
OP-190010C,H
Lever Handle Cold, Hot
B
OP-490040
Bonnet Nut
C
OP-390004
OP-390005
Cartridges-Brass Post
Cartridges-Plastic Post
ITEM #
DESCRIPTION
1
OP-490012C,H
Acrylic Handle Button Cold, Hot
2
OP-490014
Screw
3
OP-490013C,H
Mini Blade Button Cold, Hot
4
OP-490015
Handle Screw
D
OP-490041
Spring and seats
5
OP-490016C,H
Wrist Blade Button Cold, Hot
E
OP-420025
Deck Plate
6
OP-490029
Allen Screw
F
OP-420026
Base Gasket
7
OP-490035
1.5 GPM Aerator
G
OP-590003
Mounting Locknut & Washer
H
OP-590001
Supply Nut
I
OP-420018
Spout Cap & Washer
J
OP-220002
Spout
K
OP-420019
O-rings
L
OP-420020
Gasket
M
OP-420024
Diverter Piston
N
OP-420022
Side Spray Assembly
For more care information or trouble shooting inquiries
about your Olympia product, please call:
OLYMPIA FAUCETS, INC. (888) 772-7701
Central Standard Time: 8:00am ~ 7:00pm
www.olympiafaucets.com
1.
Place spray hose guide in far right hole of sink and then attach both the washer and locknut from
underneath the sink.
2.
Insert the compression nut end of spray hose down through the hose guide. Pass hose through the
center hole in base gasket and attach to the center faucet outlet, hand tightening securely. Note:
Use pipe compound or Teflon® Tape on this connection.
FINAL PRODUCT INSTALLATION:
1.
Turn on the hot and cold water. Check all around for any minor joint leaks. NOTE: Inspect for any
leaks around the connections to both the supply lines and the spray hose assembly.
2.
Remove aerator from end of spout. Flush both water lines by allowing water to run through for one
minute. Replace aerator.
CAUTION: MAKE SURE TO TIGHTEN THE AERATOR SECURELY AFTER FLUSHING THE WATER
LINES.
Olympia Faucets, Inc. © 2009
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement