me-1a massuse relay - Massuse Electric Ltd.
ME-1A
MASSUSE RELAY
FEATURES
- 1C configurations
- Subminiature size 15.5 x 10.5 x 11.5(L x W x H)
- Power consumption of standard type 360mW,
- Sensitivity type 200mW
- UL and CUL approval, File No.: E179936
CONTACT DATA
CHARACTERISTICS
Contact form
1C
Contact resistance
(Initial)
Rated load
Insulation resistance
100mΩ
Dielectric strength
2A, 3A / 24VDC
5A / 14VDC
2A, 3A, 5A / 120VAC
Rated carrying current
2A, 3A, 5A
Max. switching voltage
120VAC / 60VDC
Max. switching current
2A, 3A, 5A
Referencial min.
applicable load
10mA, 6VDC
Contact material
Silver Alloy
100MΩ at 500VDC
500VAC, between coil to contacts (1 minute)
500VAC, between open contacts (1 minute)
Operate time
Max. 8 ms
Release time
Max. 4 ms
Vibration
Endurance: 10 – 55Hz, 1.5mm
Shock
Endurance 10G, Error operation 50G
- 25℃ to + 70℃
Ambient temperature
Humidity
45% to 85%
Life expectancy
- Electrical
- Mechanical
1 x 105 operations (at rated coil voltage)
5 x 106 operations (no load)
COIL SPECIFICATIONS
1. Standard for 2A & 3A Contact
Max. allowable
Nominal voltage Pick-up voltage Drop-out voltage Nominal current Coil resistance Power
(VDC)
VDC (Max.)
VDC (Min.)
(mA±10%)
(Ω±10%)
consumption(mW) voltage (VDC)
3
2.25
0.3
120
25
360
5
3.75
0.5
72
70
360
6
4.5
0.6
60
100
360
9
6.75
0.9
40
220
360
12
9
1.2
30
400
360
24
18
2.4
15
1600
360
130% of nominal
voltage
Pick-up voltage 70% is available
2. Sensitive for 2A & 3A Contact
Nominal voltage Pick-up voltage Drop-out voltage Nominal current Coil resistance Power
Max. allowable
VDC (Min.)
(mA ± 10%)
( Ω ± 10%) consumption(mW) voltage (VDC)
(VDC)
VDC (Max.)
9
3B
2.25
0.3
66.7
45
200
5B
3.75
0.5
44.7
120
200
6B
4.5
0.6
33.3
180
200
130% of nominal
9B
6.75
0.9
22.5
400
200
voltage
12B
9
1.2
17.1
700
200
24B
18
2.4
8.6
2800
200
MASSUSE ELECTRIC LTD. Tel:(852) 2348 4720 Fax:(852) 2421 6824
E-Mail: [email protected]
ME-1A
MASSUSE RELAY
3. Coil specifications for 5A Contact
Nominal voltage Pick-up voltage Drop-out voltage Nominal current Coil resistance Power
Max. allowable
(VDC)
VDC (Max.)
VDC (Min.)
(mA ± 10%)
( Ω ± 10%) consumption(mW) voltage (VDC)
3P
2.25
0.3
150
20
450
5P
3.75
0.5
90
56
450
6P
4.5
0.6
75
80
450
9P
6.75
0.9
50
180
450
12P
9
1.2
37.5
320
450
24P
18
2.4
18.8
1280
450
110% of nominal
voltage
ORDERING INFORMATION
ME-1A
-
12
B
S
Protection
P
Model No.
Coil Voltage
Power Consumption
Contact Rating
ME-1A
3VDC – 24VDC
Nil: Standard type (2A,3A - 360mW ) Nil: Flow solder Nil: 2A
(5A – 450mW)
S: Sealed type M : 3A
B: Sensitive ( 2A,3A - 200mW )
P : 5A
t
u
o
y
a
L
B
C
P
c
i
t
a
m
e
h
c
S
A
1
E
M
Dimensions(unit:mm)
Tolerance:±0.3
1
Φ
5
5
.
0
1
5
.
5
1
2
6
.
7
6
1
.
0
1
4
5
.
2
3
.
0
4
4
.
1
2
6
.
7
4
5
.
5 2
.
0
2 6
. 1
0 .
0
1
6
.
1
Disclaimer: All the specifications are subject to change without notice.
MASSUSE ELECTRIC LTD. Tel:(852) 2348 4720
Fax:(852) 2421 6824 E-Mail: [email protected]
10