Kohler PowerScant Monitor System

Kohler PowerScant Monitor System
Kohler PowerScant Monitor System
Wireless Monitor
System Features
D
D
D
D
D
D
D
D
D
UL 2017 listed
Provides system reliability via around-the-clock monitoring
Uses wireless technology to send messages
Sends messages instantly to selected recipients
Allows customer selection of inputs, which can include
overcrank, low oil pressure, high engine temperature, door
open, and common fault alarms
Allows the customer to select the delivery method to alert
recipients: cell phone, pager (alphanumeric and numeric),
fax, XML-based messaging, voice mail, or e-mail
Results in the dispatch of the best qualified technician
Reduces unplanned outages
Provides remote start/stop capability *
Hardware Features
D
D
D
D
D
Communication Features
D Wireless monitor receives data from the equipment
controller
D Monitor sends alarms over the North American AMPS
(advanced mobile phone system) to the operations center
server
D Operations center annunciates alarm messages via the
customer-selected delivery method
D Monitor communicates via Modbusr connection or via
discrete inputs
D Monitor scans alarm messages every 2--3 seconds
D System manages multiple alarms as required
D
D
D
D
D
Website Features
D Uses the power of the Internet to view activity
D Operations center manages equipment data for website
access
D Messages are reported in text format with time and date
stamps identifying target recipient
D Information contains the alarm condition, equipment
make/model, and equipment location
D Monitors and records equipment operation on a
password-protected website
D Monitor sends a heartbeat message every 24 hours with
system information to confirm operation. Device failure
produces Unit Failed to Report Heartbeat alarm message
D Records equipment runtimes
D Monitors service button activation to verify on-site
response
D Displays generator set battery low alarm
Easy installation and activation
Dry contact and voltage inputs
Lockable enclosure with mounting tabs
356 mm (14 in.) antenna with weather-resistant connector
LED indicators to verify communication and operation
d Yellow: indicates service ready, transmitting message,
or no service
d Green: indicates successful message transmission,
waiting to transmit, or no service
d Red: indicates active input (viewable above each input
when panel is removed)
LED display indicates signal strength of cellular
transmission or service mode
Service button to signal on-site response
Alarm silence button to silence audible alarms and provide
a diagnostic code
Knockouts for cable entry
DIP switches:
d Enable/disable remote start/stop *
d Enable/disable audible alarm
d NO/NC input selection
d AC/DC power supply selection
Specifications
D Power supply: 85--120 VAC @ 60 Hz or 12/24 VDC
D Current draw: 1.5 amps maximum
D Operating temperature range: --40° to 60°C
(--40° to 140°F)
D Storage temperature range: --40° to 70°C (--40° to 160°F)
D Humidity range: 5--95% noncondensing
D Enclosure: Type 4, approved for outdoor installation,
surface mountable
D Voltage input rating: 24--120 VAC or 5--48 VDC
* Disable connected equipment during maintenance or service to prevent accidental starting. See the equipment Operation Manual for instructions.
Modbusr is a registered trademark of Schneider Electric
G6-53 7/06c
KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-565-3381, Fax 920-459-1646
For the nearest sales and service outlet in the
US and Canada, phone 1-800-544-2444
KohlerPowerSystems.com
Models
Installation and Startup
For easy installation and startup:
Wireless
Monitor
Model
Power
Requirement
Description
GM29535
120 VAC or
12/24 VDC
Includes 7 hardwire inputs:
4 dry contact inputs and
3 voltage inputs.
GM29536
120 VAC or
12/24 VDC
Uses Modbusr
communication. Also
includes 8 hardwire inputs
(4 dry contact and 4 voltage
inputs).
Modbusr is a registered trademark of Schneider Electric
D
D
D
D
D
D
D
D
Accessories
D
UL-listed wireless monitor models GM29535 and GM29536
include the standard 356 mm (14 in.) antenna. Additional
accessories are available; contact your distributor/dealer for
information.
Cell Coverage
Before placing an order, check the cell coverage map located
on the Kohler website at KohlerPowerSystems.com to
determine coverage at your zip code.
Dimensions
STANDARD 3dB GAIN, 14 INCH ANTENNA
SHIPPED LOOSE INSIDE OF ENCLOSURE
90.5
3x
5.6
244.5
LATCH
57.2
274.6
ANTENNA CONNECTOR
1--1/8--18 THD
260.4
355.6 [REF]
Connect the antenna to the enclosure.
Check the signal strength before mounting.
Mount the enclosure.
Connect the outputs from the monitored equipment. Refer to
the equipment manufacturer’s instructions for connection
diagrams.
Connect the unit to a 12 VDC, 24 VDC, or 120 VAC/60 Hz
power source. (Provide a step-down transformer for sources
greater than 120 VAC.)
Connect the battery pack (AC models only).
Record the transmitter device ID number from the device
label.
Access the website (KohlerPowerSystems.com) to activate
the system and set up message delivery.
Refer to TP-6223, Operation Manual, and TT-1370,
Installation Instructions, for detailed operation information
including device configuration instructions.
61.9
181.0
95.25
211.1
Dimensions are in mm.
DISTRIBUTED BY:
3X .50 & .75 INCH
CONCENTRIC CONDUIT KNOCKOUTS
Availability is subject to change without notice. Kohler Co. reserves the
right to change the design or specifications without notice and without
any obligation or liability whatsoever. Contact your local Kohlerr
generator distributor for availability.
© 2002, 2003, 2004, 2006 by Kohler Co. All rights reserved.
G6-53 7/06c