Manual do Proprietário Manual del usuario
Dear Customer,
Thank you for purchasing this product.
For optimum performance and safety, please read these instructions carefully.
User Memo:
Date of purchase:
Dealer name:
Dealer address:
Dealer website:
Dealer email:
Dealer phone no.:
Please visit us on facebook or twitter!
https://www.facebook.com/Maxspect
English
http://twitter.com/maxspectled
1
English
Please check the content in the package.
XF230 / XF250
Controller Unit Power Supply Unit
Package Content
XF280
Controller Unit
2
Precautions
Before using this Maxspect™ Gyre System please read these operating instructions carefully. Take special care to follow the safety suggestions listed below.
Afterwards keep this manual handy for future reference.
Before using the Maxspect
™
Gyre System
1. Remove any plastic bags and packaging material protecting the pump and controller unit.
Safety on Power Supply
1. Power Source – Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
2. Power Cord Protection – The power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them. Never take hold of the plug or cord if your hand is wet, and always grasp the plug body when connecting or disconnecting it.
3. Installation – Install indoor only, and use the attachments and accessories provided and specified by the manufacturer.
Safety on Magnet Mount
1. CAUTION - Very strong magnetic mount included in the package.
2. CAUTION - keep the magnet mount out of reach of children, as there is risk of severe personal injury otherwise!
3. Handle the magnet mount with their proper handle, and do not bring the both side together directly. Do not put your fingers between the magnet mounts.
4. Magnet mount can attract metal objects, keep clear of metal objects when handling the magnetic mount to avoid injuries.
5. Magnet mount can also damage electronic and magnetic storage devices such as USB storage devices, pacemakers, credit cards, etc. Keep clear of these devices when handling the magnetic mount to avoid damaging them.
English
3
English
Precautions
Safety on Pulsing Motion generated by the Gyre System
1. Making pulses and waves with the Gyre System can place additional stress on the aquarium glass/acrylic and its joints. Not all aquariums are able or designed to withstand this stress and failure of the glass/acrylic and/or joints could result. Please consult with your aquarium manufacturer to determine if the aquarium construction is adequate to withstand the additional stress generated by the pulses and waves motion. Please also check to assure that your aquarium stand or furniture is properly leveled, which will help reduce the additional stress resulting from wave generation.
2. Maxspect DISCLAIMS AND WILL NOT BE LIABLE FOR, damage to any aquarium or their surroundings, water damage, or any other consequential damages resulting from wave generation. MAKE PULSES AND WAVES AT YOUR OWN RISK.
Operation – Controller Unit
1. Operation – Always follow the operation instructions set forth in this manual when using this controller unit.
2. Heat – The controller unit should be situated away from heat sources such as radiators, and do not expose to excessive heat such as sunshine, fire or the like.
3. Moisture – To reduce the risk of fire or electric shock, do not expose the controller unit to rain, moisture, dripping or splashing.
4. Water Damage – DO NOT immerse in water. If the controller unit falls into the water,
DO NOT reaches for it! First unplug it and then retrieve it. If electrical components of the appliance get wet, unplug the appliance immediately.
Operation – Gyre Pump
1. Placement – The Gyre pump creates high levels of flow within your aquarium. Please place the Gyre in an area where corals are not too close to the output flow of the pump.
2. Stall – In the event of a motor stall, the Gyre pump may have stopped for a few possible reasons. You should first check that there is not something blocking the rotors from spinning.
3. Overheating – The Gyre pump is designed to run underwater. Do not run the Gyre pump when it is not submerged in water. Doing so will cause the Gyre pump module to overheat and could damage the pump component.
4. Cleaning – Please follow the instruction in this manual to clean the Gyre regularly.
5. Power Outage – During power outage, if a battery backup accessory is added to the
Gyre pump, the pump will automatically switch to Battery Backup mode during a power outage. The pumps will run at the minimum speed to maximize their run time during this critical period.
4
Installation
Connecting the Gyre System
1. The Gyre System has a built-in safety mechanism. You must first
connect the cable from the Controller to the Gyre Pump then connect the cable from the Power Supply to the Controller.
English
XF230/XF250
XF280
5
English
The Gyre Controller Unit
Operating Instructions
Setup Mode Button
Switch Mode Button
Indicator Lights
Switching between modes
Control Dial
Feeding mode
Set time / Battery backup setting mode
6
Operating Instructions
OLED Screen Icon
Water Movement Modes
Constant Speed Mode
Pulsing Mode
Gradual Pulsing Mode
Random Mode
Alternating Gyre Mode
Variables
Maximum flow
Minimum flow
Variables Illustrated
Ramp up time
Maximum flow time
Link-up Methods
Synchronized
Anti-Synchronized
Timed Delay
Reversed Timed Delay
Wind down time
Minimum flow time
English
7
English
#1
#2
#3
#4
#5
#6
Operating Instructions
Manual Mode
Enter manual setting mode
Select Pump A or
Pump B
Select Water
Movement Mode for selected pump
Enter the variables for this
Water Movement
Mode for Pump A
For Pump B, it is also possible to select Link-up
Method
Confirm and exit setting mode
8
#1
#2
#3
#4
#5
#6
9
Operating Instructions
Auto Mode (24 hours cycle)
Set the time first
English
#2 #5
Enter auto setting mode
Select time point and assign time
Repeat Step 2 to
Step 5 of Manual
Mode to set up the 2 pumps
Switch to the next time point
When finished, confirm and exit auto setting mode
English
Constant Speed Mode
Operating Instructions
Configurable Variables
User Input
--
--
--
--
--
10
Constant Speed Mode
Operating Instructions
English
11
English
Pulsing Mode
Operating Instructions
Configurable Variables
User Input
--
0.4s
User Input
0.4s
--
12
Pulsing Mode
Operating Instructions
English
13
English
Gradual Pulsing Mode
Operating Instructions
Configurable Variables
User Input
--
0.4s
User Input
0.4s
--
14
Gradual Pulsing Mode
Operating Instructions
English
15
English
Random Mode
Operating Instructions
Configurable Variables
User Input
Randomized
0.4s
Randomized
0.4s
Randomized
16
Random Mode
Operating Instructions
English
17
English
Alternating Gyre Mode
Operating Instructions
Configurable Variables
User Input
User Input
User Input
User Input
User Input
User Input
18
Alternating Gyre Mode
Operating Instructions
English
19
English
Operating Instructions
Link-up Method Samples Illustrated
24-hours Cycle Illustrated
20
Operating Instructions
Preset 1 – Lunar Tidal Cycle (LTC)
The Lunar Tidal Cycle (LTC) is a 24-hours cycle that mimic the kind of water current in the ocean during high and low tides.
English
21
English
Maintenance Instructions
Preset 2 – Oceanic Gyre Cycle (OGC)
The Oceanic Gyre Cycle (OGC) is a 24-hours cycle that creates a gentle alternating gyre circulation within your aquarium.
22
Limited Warranty
Maxspect (HongKong) Limited warrants all Maxspect™ Gyre products against defects in workmanship for a period of 12-months from the date of purchase. If a defect exists during the warranty period, Maxspect at its option will either repair (using new or remanufactured parts) or replace (with a new or remanufactured unit) the product at no charge.
There is a possibility that the Gyre pump may cause damage to your aquarium. Please contact your aquarium manufacturer to determine if your aquarium is properly built and recommended for wave action. If you notice any damage to your aquarium, including but not limited to cracking, bending, scratching, etc., immediately discontinue the use of the Gyre pump. Maxspect will not be liable for any damage caused to your aquarium resulting from the use of Gyre pump.
English
DISCLAIMER OF CONSEQUENTIAL AND INCIDENTAL DAMAGES:
THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU
OF ALL OTHER WARRANTIES AND REMEDIES, WHETHER ORAL OR WRITTEN, EXPRESS OR
IMPLIED. TO THE FULL EXTENT PERMITTED BY LAW, MAXSPECT EXPRESSLY DISCLAIMS ANY
AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF
IMPLIED WARRANTIES CANNOT BE DISCLAIMED, ALL SUCH IMPLIED WARRANTIES ARE
LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY.
MAXSPECT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN
THIS WARRANTY. IN NO EVENT SHALL MAXSPECT AND ITS DISTRIBUTORS BE LIABLE OR
RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. MAXSPECT’S AGGREGATE
LIABILITY UNDER THIS WARRANTY OR WITH RESPECT TO ANY PRODUCT COVERED HEREBY,
UNDER ANY LEGAL THEORY, SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE
NONCONFORMING PRODUCT.
NO ONE IS AUTHORIZED TO CHANGE THIS LIMITED WARRANTY IN ANY RESPECT OR TO
CREATE ANY OTHER OBLIGATION OR LIABILITY FOR MAXSPECT IN CONNECTION WITH THE
GYRE PUMP. MAXSPECT DISCLAIMS ALL LIABILITY FOR THE ACTS, OMISSIONS AND
CONDUCT OF ALL THIRD PARTIES (including, without limitation, the installing contractor) IN
CONNECTION WITH OR RELATED TO THE GYRE PUMP.
23
English
Limited Warranty
UNDER NO CIRCUMSTANCES SHALL MAXSPECT AND ITS DISTRIBUTORS BE LIABLE FOR ANY
INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, WITHOUT LIMITATION,
LOST GOODWILL, LOST REVENUES OR PROFITS, WORK STOPPAGE, AQUARIUM SYSTEM
FAILURE, IMPAIRMENT OF OTHER GOODS, COSTS OF REMOVAL AND REINSTALLATION OF
THE GYRE PUMP, LOSS OF USE, DAMAGE TO YOUR AQUARIUM OR ANY AQUARIUM
INHABITANTS, INJURY TO PERSONS OR PROPERTY ARISING OUT OR RELATED TO THE GYRE
PUMP WHETHER BASED ON BREACH OF WARRANTY, BREACH OF CONTRACT, TORT OR
OTHERWISE, EVEN IF MAXSPECT AND ITS DISTRIBUTORS HAVE BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE. IF YOU DISAGREE WITH THESE TERMS AND CONDITIONS
DO NOT USE THE MAXSPECT GYRE PUMP.
Specifications
Note:
For latest specifications on the Gyre pump and controller, please visit our website at www.maxspect.com
Specifications are subject to change without notice.
Weight and dimensions are approximate.
24