Ashcroft 2084, 2086, 2089 Digital Test Gauge Operating Instructions

Below you will find brief information for Digital Test Gauge 2089, Digital Test Gauge 2086, Digital Test Gauge 2084. The Ashcroft Digital Test Gauge gives you the largest display readout in the industry with a .66˝ display and a 5-digit readout. It also has several features designed to simplify your work in the field, such as a range printed on the keypad and selectable engineering units, including psi, ˝Hg, ˝H2O (with three temperature options, 60°F, 4°C and 20°C), ft.SW, bar, mbar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2. The gauge is weatherproof and rated IP65. It includes a 300 Series SS protective cover and nylon carrying pouch.

PDF Download
Document
Ashcroft Digital Test Gauge 2089, 2086, 2084 Operating Instructions | Manualzz

Advertisement

Advertisement

Advertisement

Key features

  • Full Scale Terminal Point Total Error Band (TEB) Accuracy
  • Largest Display Readout in the Industry
  • Twelve Selectable Engineering Units
  • Seven Languages
  • Password-Protected Disable and Calibration Functions
  • Range Printed on Keypad (ASME B40.7 Compliance)
  • Weatherproof, IP65 Enclosure Rating
  • 300 Series SS Protective Cover
  • Nylon Protective Carrying Pouch

Frequently asked questions

To replace the batteries, remove the single screw on the back of the gauge case. Hold the keypad in the palm of your hand. Carefully remove the three batteries from the holder and replace the batteries. Use only AAA alkaline non-rechargeable batteries.

The Ashcroft Digital Test Gauge is available in three accuracy levels: 0.05%, 0.10%, and 0.25%. All accuracy levels are Full Scale Terminal Point Total Error Band (TEB) Accuracy including Hysteresis, Linearity, Repeatablility & Temperature.

The factory default password for the Ashcroft Digital Test Gauge is ØØØØØ. This password does not allow access to calibration. To access the calibration mode, you must configure a user password.

The Ashcroft Digital Test Gauge is available in a variety of ranges, including vacuum through 7000 psi. See the engineering units section of the manual for a complete list of available ranges.

The Ashcroft Digital Test Gauge allows for both zero and span adjustments. To access calibration, you must first configure a user password. Once a user password is configured, you can access the calibration mode through the CONFIG menu. Ensure the gauge is not pressurized while adjusting the zero point, then press ENTER. To adjust the span, pressurize the gauge to 100% of the range, then press ENTER.