GAT NET.Lock 7000 Electronic Locker Locks

GAT NET.Lock 7000 Electronic Locker Locks
GAT N ET.Lock 7000
Electronic Locker Locks
Application
locking of wardrobe lockers in fitness clubs, baths, golf resorts, and other
individual company applications. The identification at the GAT NET.Lock
7000 is carried out via contactless RFID data carriers (Radio Frequency
Identification).
The GAT NET.Lock 7000 is suitable for different locker door materials
(wood, HPL, fully synthetic materials, glass or even metal doors when
using the booster unit) and is useable for doors that open to the left or
right. The various operating modes enable the flexible use of these locks.
GAT NET.Lock BoltSet 7100
The GAT NET.Lock 7000 is the ideal solution for the convenient electronic
Slave controllers GAT NET.Controller S 7000 are used for communication
and control of the GAT NET.Lock 7000. They are available for several
RFID technologies (LEGIC® and MIFARETM + ISO 15693).
GAT NET.Lock 7000
Functional description
Order information
The electronic locks GAT NET.Lock 7000 are connected to slave control-
Description
lers GAT NET.Controller S 7000. Up to 24 locks can be connected to one
slave controller. Each slave controller in a system is further connected via
serial RS 485 interface to a master controller GAT NET.Controller M 7000.
To use a locker, the user presses the locker door shut and holds his data
carrier up to the reader centre of the GAT NET.Lock 7000. The lock reads
the data carrier information and sends the information to the slave con-
GAT NET.Lock 7000
PartNo.
368534
Electronic RFID locker lock
Accessories
Description
troller. Depending on the operation type (Online/Offline) the user data
GAT NET.Controller M 7000
are checked by the controller autonomously or by a PC software on the
Master controller for the slave controllers GAT NET.
server. The controller or server response will then signal the lock to lock
Controller S 7000
PartNo.
253224
or unlock the locker door. The locking status of the door is signalled by
GAT NET.Controller S 7000 B
the lock‘s status LED.
253325
Slave control unit for the electronic locker locks GAT NET.
Highlights
Lock 7000, with integrated LEGIC® reader.
•Up to 24 GAT NET.Lock 7000 per GAT NET.Controller S 7000
GAT NET.Controller S 7000 F/ISO
•Different operation modes possible
253426
Slave control unit for the electronic locker locks GAT NET.
•Reliable data transmission between the reader and data carrier
Lock 7000, with integrated MIFARETM/ISO 15693 reader.
•For left and right doors and various types of locker doors
•Self-adjustment of the RFID field
GAT NET.Lock Tool 7000
•LED status display (multi-colour)
533831
Center punch gage for bolt mounting
•Motor driven locking/unlocking for highest reliability
•Different bolt sets with integrated RFID booster
GAT NET.Lock Connector
•Easy and secure bolt mounting
Connector for connection cables
442123
•Front plate for metallic doors (for labelling with locker number and logo
etc.), individual designs possible
GAT NET.Lock Cable 4m
321826
Cable for connection of the GAT NET.Lock 7000, length 4 m,
Accessories
Description
4-pin plug on both sides
PartNo.
GAT NET.Lock Basic Set B
369131
GAT NET.Lock Basic Set F
369232
GAT NET.Lock Basic Set ISO
369333
The sets include master cards
GAT NET.Lock BoltSet 7100
369535
Door shackle carrier and booster for non-metallic doors
GAT NET.Lock BoltSet 7200
Door shackle carrier and booster for metallic doors
www.gantner.com
532123
GAT NET.Lock Label GEA right
679034
GAT NET.Lock Label GEA NUM right
679236
Self-adhesive door label in GANTNER design, for righthinged doors, without/with locker number
GAT NET.Lock Label GEA left
370022
GAT NET.Lock Label GEA NUM left
679135
Self-adhesive door label in GANTNER design, for lefthinged doors, without/with locker number
Valid as from September 27 th 2013 • Technical data subject to modifications without notice!
DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734
1
Technical Data
Nominal voltage UDC:
5V
Number locks per slave cont.:
24
Power supply:
Via connection cable from the slave
controller
Connectors:
MOLEX, type Micro-Fit 3.0TM
Housing material:
Plastic (PC)
Aver. power consumption:
60 mW
Door width:
min. 230 mm
Dimensions:
110 x 100 x 25 mm
Reader types:
GAT NET.Controller S 7000
- B:
- F/ISO:
LEGIC®
MIFARETM + ISO 15693
Permitted ambient temperature: 0 to +60°C
Protection type:
IP 52
Retaining force:
Min. 1,500 N
Protection class:
III
Force on inner side of the door: Max. 100 N
Weight:
Approx 160 g
User guidance
Multi-Colour status LED
Interface:
One-Wire (special cable for supply,
data and RF signal)
Environment class
based on VDS 2110:
II (conditions in indoor areas)
Dimensions
GAT NET.Lock BoltSet 7200
Top View
5
7
5
6
2
4
3
7
1
5
6
3
3
7
8
110.0 mm (4.33”)
40.3 mm (1.58”)
91.0 mm (3.58”)
110.0 mm (4.33”)
6.0 mm (0.24”)
91.0 mm (3.58”)
17.0 mm (0.67”)
6.0 mm (0.24”)
17.0 mm (0.67”)
6.0 mm (0.24”)
17.0 mm (0.67”)
40.3
mm
(1.58”)
91.0
mm
(3.58”)
110.0 mm (4.33”)
7
6
7
6
40.3 mm (1.58”)
1. GAT NET.Lock 7000
5. Door contact
2. GAT NET.Lock Bolt Set 7100 (for non-metal doors)
6. Booster
3. GAT NET.Lock Bolt Set 7200 (for metal doors)
7. Status LED
4. Door shackle
8. Label Carrier
61.8 mm (2.43”)
61.8 mm (2.43”)
78.0 mm (3.07”)
Typical application
to the server/host
Ethernet
Supply
Master Controller
GAT NET.Controller M 7000
Supply
Master Controller
GAT NET.Controller M 7000
OUT
OUT
RS 485
RS 485
RS 485 + power
RS 485 + power
Supply
GAT NET.Controller S 7000
Power
Plug
GAT NET.Controller S 7000
GAT NET.Controller S 7000
Supply
OUT
OUT
OUT
IN
IN
IN
Max. 8 slave controllers at one master controller
Max 200 m line length per RS 485 line
GAT NET.Lock 7000
Identification with RFID data carrier
Lockers
2
Valid as from September 27 th 2013 • Technical data subject to modifications without notice!
DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734
www.gantner.com
88.1 mm (3.47”)
6
3
4
8
104.5 mm (4.11”)
7
1
4
Front View
88.1 mm (3.47”)
2
1
2
4
8
Front View
Front View
88.1 mm (3.47”)
4
2
4
100.0 mm (3.94”)
50.0 mm (1.97”)
5
1
3
Side View
50.0 mm (1.97”)
4
2
5
Side
View
Front
View
100.0 mm (3.94”)
1
3
Front ViewSide View
100.0 mm (3.94”)
Side View
4
4
2
94.0 mm (3.7”)
View
1
4
8
1
88.1 mm (3.47”)
2
25.0 mm (0.98”)
4
8
88.1
94.0mm
mm(3.47”)
(3.7”)
4
Top View
1
50.0 mm (1.97”)
1
1
4
25.0 mm (0.98”)
Top View
25.0 mm (0.98”)
ew
Top View
GAT NET.Lock BoltSet 7100
94.0 mm (3.7”)
GAT NET.Lock 7000
7
Mounting and Installation Instructions
The GAT NET.Lock 7000 is mounted with 3 screws (1) on the inside of the
Door width
locker. The bolt set with the door shackle is mounted on the inside of the
The minimum allowed door width (measured from the door shackle to the
locker door. At non-metallic doors only a drilling for the LED is required. At
hinge) is 230 mm. If the door is narrower than this measure, the door
metallic doors a cut-out must be made in the door, where the bolt set and
shackle would hit the locker when the door is being closed.
label carrier will be mounted.
Door status contact
The GAT NET.Lock 7000 has a contact which gets activated by the door
contact (5) at the bolt set as soon as the locker door is closed. This allows
to determine the open/close state of the door. To guarantee the correct
Locker wall
clean and not damaged.
Centre of rotation of hinge
Locker wall
functionality of the GAT NET.Lock 7000 it is important that this contact is
Locker door
min. 230 mm
Mounting on Non-Metallic Doors
3
6
1
3
1
6
4
2
2.GAT NET.Lock Bolt Set 7100
17.0 mm
33.6 mm
3
6
82 mm
7
5
3
2.4 mm
10.1 mm
14.6 mm
74.0 mm
17.0 - 17.5 mm
8.0 mm
Installation measures for GAT NET.Lock 7000 and Bolt Set
6
6.6 mm
7
1. GAT NET.Lock 7000
3
3
Locker door
60.1 mm
6.0 mm
Middle of the opening
for the door shakle
50.0 mm
94.0 mm
1.0 mm
2
3.Mounting screws for GAT NET.Lock 7000
4. Door shackle
5. Door contact
6.Mounting screws for bolt set
7.LED (hole in locker door)
17.6 mm
25.1 mm
3. Mount the GAT NET.Lock 7000 with three screws (3) on the inside
locker wall.
During the mounting, please pay particular attention to the following points:
- When the door is pressed shut, the gap between the bolt set (2) and the
front of the GAT NET.Lock 7000 must not be exceed 0.5 mm. Ideally the
Note: Use the right screws according to the type of locker material.
Attention: The max. allowed tightening torque of the screws
bolt set should touch the front of the lock.
is 2 Nm.
- The middle of the door shackle (4) must be 1 mm higher than the middle
of the door shackle opening in the GAT NET.Lock 7000. This ensures
4. Drill the three holes (6) for mounting the GAT NET.Lock Bolt Set 7100.
the door’s ability to close even if the door position is modified 3 mm
5. Drill a hole for the LED display in the locker door (7). The recommended
hole diameter is 10 mm.
downwards or 1 mm upwards (tolerance ±2 mm).
Note: A front label can be used to cover the LED hole. If the customer
designs the label he must pay attention that a transparent field for the
LED light should be placed on the label.
Mounting procedure
Note: Before mounting all locks of the locker system a test installation of
at least one lock and final function check must be performed like
described below. Only if the tests are successful the rest of the
locks may be mounted in the same way.
2. Plug-in the connection cable (see page 6).
www.gantner.com
Note: Use the right type and length of the screws according to the
type of locker material.
Attention: The max. allowed tightening torque of the screws
1. Drill the three holes (3) for the GAT NET.Lock 7000 into the locker
wall.
6. Mount the bolt set onto the locker door by using three screws.
is 2 Nm.
7. Close the locker door to test, if the door can be closed easily and the
door shackle inserts into the opening in the GAT NET.Lock 7000.
Valid as from September 27 th 2013 • Technical data subject to modifications without notice!
DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734
3
6
3
1.0 mm
9
Locker wall
Locker wall
(Front
6
12
10
3
7
32.6 mm
5
17.0 mm
6
Locker Door
(Front view with lable carrier)
2
3
3
Middle of the opening
for the door shakle
1
3
1
4
60.1 mm
6.0 mm
94.0 mm
50.0 mm
Locker Door
(Front view without lable carrier)
Locker wall
Locker door (inside wall)
Locker door (outside wall)
Mounting on Metallic Doors
3
7
7
6
74.0 mm
15.1 mm
2
17.0 - 17.5 mm
Inside of Locker
min. 18 mm
max. 26 mm
1. GAT NET.Lock 7000
Installation measures for GAT NET.Lock 7000 and Bolt Set
2. GAT NET.Lock Bolt Set 7200
During the mounting, please pay particular attention to the following points:
3. Mounting screws for GAT NET.Lock 7000
- The door thickness must be between 18 and 26 mm (see figure).
4. Door shackle
- When the door is pressed shut, the gap between the bolt set (2) and the
5. Door contact
front of the GAT NET.Lock 7000 must not be exceed 0.5 mm. Ideally the
6. Mounting screws for bolt set
bolt set should touch the front of the lock.
7.
LED position
8. Cut-out for GAT NET.Lock Bolt Set 7200
- The middle of the door shackle (4) must be 1 mm higher than the middle
of the door shackle opening in the GAT NET.Lock 7000. This ensures
9. Cut-out for label carrier
the door’s ability to close even if the door position is modified 3 mm
10. Label carrier
downwards or 1 mm upwards (tolerance ±2 mm).
Locker wall
Locker door (inside wall)
Locker door (outside wall)
Cut-outs in the Locker Door
On the inside and outside walls of the
Locker Door (Front view)
9
locker door cut-outs must be made in
order to mount the GAT NET.Lock Bolt Set
7200 and the label carrier. The mounting
8
procedure is described on the next page.
80.4
6
Cut-Out on inside wall
Cut-Out on outside wall
83.6
The measurements for the cut-outs are
shown in the figure to the left.
LED
8
9
6
0.8 17.6
1.7
13.1
46.6
Lock base
11.1
6.6
Lock bottom edge
63.4
65.9
Inside of Locker
4
79.1
4 x holes for screws,
Ø 3.6 mm, see step 7
on page 5
All measures in mm.
Valid as from September 27 th 2013 • Technical data subject to modifications without notice!
DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734
www.gantner.com
Mounting procedure
Note: Before mounting all locks of the locker system a test installation of
at least one lock and final function check must be performed like
described below. Only if the tests are successful the rest of the
locks may be mounted in the same way.
1. Drill the 3 holes (3) for the GAT NET.Lock 7000 into the locker wall.
2. Plug-in the connection cable (see page 6).
3. Mount the GAT NET.Lock 7000 with 3 screws (3) on the inside locker
wall.
Note: Use the right screws according to the type of locker material.
Attention: The max. allowed tightening torque of the screws
is 2 Nm.
4. On the inner wall of the locker door make the cut-out (62.6 x 68 mm)
for the GAT NET.Lock Bolt Set 7200.
5. On the inner wall of the locker door drill the 4 holes (6) for mounting
the GAT NET.Lock Bolt Set 7200.
6. On the outer wall of the locker door make the cut-out (67.6 x 93.5 mm)
for the label carrier.
7. Mount the bolt set onto the inside wall of the locker door by using 4
screws as shown in the figure on the previous page.
Note: Only use Torx pan-head metal screws, Ø 3.5 mm, length 9.5 mm.
Attention: The max. allowed tightening torque of the screws
is 2 Nm.
8. Push the label carrier onto the outside wall of the locker door. The
label carrier will hold in place with the lashes on the label carrier. No
screws are required.
9. Stick the front label (11) onto the label carrier.
Note: A customer-specific front label can be used to cover the LED
hole. A transparent field should be placed on the label to show
the LED light.
Locker Door
(Front view with lable carrier)
Locker wall
Locker Door
h lable carrier)
123
11
7
10.Close the door to test, if the locker door can be closed easily and if the
door shackle inserts into the opening of the GAT NET.Lock 7000.
www.gantner.com
Valid as from September 27 th 2013 • Technical data subject to modifications without notice!
DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734
5
Electrical Connection
GAT NET.Lock 7000 Back Side
1
1
1
1
1
Connection Cable
Cable Outlets
To connect the GAT NET.Lock 7000 to a GAT NET.Controller S 7000
Cut-out one of these outlets (1) in order to feed the cable out of the
use the GAT NET.Lock Cable with 4-pin MOLEX plug on both ends. It is
housing.
possible to connect 2 of these cables by using a GAT NET.Lock Connector
(see order information).
Configuration
To connect a GAT NET.Lock 7000 only an original cable from
The configuration of the GAT NET.Lock 7000 and the controllers, where
GANTNER Electronic GmbH may be used.
the GAT NET.Lock 7000 is connected, is done via the GAT Relaxx PC
software. The configuration is described in the GAT NET.Lock 7000 and
the GAT Relaxx manuals.
Power Supply and Signal Lines
DC power supply (see technical data) for unlocking and for the RFID
reading field.
Antenna Adjustment
The GAT NET.Lock 7000 can automatically adjust the RFID antenna. A
description can be found in the manual of the GAT NET.Lock 7000.
Safety instructions
- This device must be installed by qualified personnel only.
- The applicable safety and accident prevention regulations
must be observed.
- Safety devices must not be removed.
- Please observe the technical data of the device specified
on the data sheet.
- The device must be disconnected from the power supply
prior to installation, assembly or dismantling.
6
Valid as from September 27 th 2013 • Technical data subject to modifications without notice!
DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734
www.gantner.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising