Leyman FDCxxRM Fold-A-Vador lift gate Operation, Maintenance, Trouble-Shooting and Parts Manual
Below you will find brief information for Lift Gate FDCxxRM. This manual covers operation, maintenance, troubleshooting, and parts for the Leyman FDCxxRM Fold-A-Vador rail-style lift gate. It details safe operation procedures, preventative maintenance schedules, and troubleshooting guidance for common issues. The manual includes diagrams and part lists to assist with repairs and maintenance.
Advertisement
Advertisement
Operation, Maintenance,
Trouble-Shooting and Parts Manual
FDCxxRM Fold-A-Vador
Rail Style
10900 Kenwood Road
•
Cincinnati, OH 45242
Ph: 513.891.6210
•
Toll-Free: 866.539.6261
Fax: 513.891.4901
www.leymanlift.com
•
LML00126-04-09-04
INTRODUCTION
This manuals contains the operating procedures on the equipment your company is using that was manufactured by Leyman Manufacturing Corporation.
Past experience has indicated that it is most unwise to operate these units without proper instructions which should be instituted by the purchaser.
While these products have certain safety features engineered into their design, they are all operated by human beings. Therein lies the problem of safety and one should always have caution in mind when operating this or any other machine that has parts that weigh several hundred pounds.
Again, let us remind you that there are moving parts on this product that weigh several hundred pounds.
These parts, when not under proper control, can cause physical damage to the operator. Because of the weights that are involved; carelessness and neglect of training can make these units dangerous.
Do not overload this product. Maintain it properly. Stand clear of moving parts. Operate as instructed.
This lift gate has a long life expectancy and will take some abuse. Use good judgement when operating this equipment.
CUSTOMER:
MODEL:
CAPACITY:
TYPE:
POWER:
PLATFORM:
SERIAL #:
OPTIONS:
PLEASE FILL IN FOR YOUR RECORDS
FDC-xxRM
lbs.
POWER CLOSE PLATFORM
12 VOLT
TWO PIECE
Power Close Platform
MAXIMUM HEIGHT 56"
HYDRAULIC PRESSURE LOADED 2,000 PSI AT THE PUMP
WHEN PLACING A PARTS ORDER, YOU WILL NEED THE
SERIAL # AND MODEL # OF THE LIFT GATE.
Due to the numerous different types and grades of steels and aluminums used in the production of these lift gates, NO material may be used as a replacement without the expressed written permission of Leyman Manufacturing Corporation.
This manual reflects most changes and updates of material numbers that are common to this type of lift gate.
Some may differ due to individual customer requirements.
This manual has been established to reflect the common items.
WORDS OF CAUTION
2.
3.
4.
1.
10.
11.
12.
13.
14.
15.
5.
8.
9.
6.
7.
Before any maintenance is performed on this unit, carefully read and understand this manual completely.
Do not stand on or behind the platform when operating gate in the folding position.
Make sure the ground is clear under the platform when lowering.
Do not stand in front of the platform when lowering from vertical position or operating in any manner.
Never exceed the rated load capacity of this gate.
Inspect the tracks for wear every six (6) months.
Inspect the hydraulic ram packings for leakage every six (6) months.
Inspect the hydraulic lines for cracks or deterioration every six (6) months.
Check the level of the hydraulic oil in the power unit tank once a month.
Clean the hydraulic power unit strainer and in-line filter every three (3) months.
Use only factory authorized parts for replacement. (See section #4)
Always disconnect the battery from the power source before servicing the unit.
Do not allow persons to operate the unit unless they have been properly trained to do so.
Check the area around the unit for persons before operating the lift gate.
This lift gate should operate smoothly and the only noise that should be heard is the power unit. Any audible sounds other than the normal power unit operation sound should be thoroughly inspected and the cause of the noise should be pin-pointed and corrected.
TABLE OF CONTENTS
TOPIC COVERED
General Terminology
OPERATING THE LIFT GATE
Operating the Lift Gate
PAGE
#
1
2
3
TOPIC COVERED
PARTS REPLACEMENT
Power Unit Parts
Hydraulic Assembly
Hand Pump Operation
MAINTAINING THE LIFT GATE
Recommended Oils and Lubrication
Preventive Maintenance Schedule
TROUBLE SHOOTING
Trouble Shooting Chart for Power Unit
Electric Diagram -Gravity Down
Electric Diagram - Power Down
Walk Around Diagram - Gravity Down
Walk Around Diagram - Power Down
Switch Wiring - Gravity Down
Switch Wiring - Power Down
Battery Hook up
13
14
Grounding Recommendations 18
Maintenance Minder Start Switch 19
15
16
17
6
7
8
4
5
Power Fold Assembly
Roller Parts
Platform Pins and Bushings
Power Unit Assembly - Gravity Down
Power Unit Assembly - Power Down
9 - 10 Hand Pump Assembly - Gravity Down
11 Hand Pump Assembly - Power Down
12 Installation of Decals
Maintenance Minder2 20
General tips for Lift Gate and Power Unit 21
Bleeding the Power Fold Ram 22
Bleeding the Lifting Cylinder 23
Adjusting the Equalizer Valve
Straightening the Tie Bar
Lubricating the Roller Tracks
24
25
26
PAGE #
27
28
29
30
31
32
33 - 34
35 - 36
37
38
39 - 41
GENERAL TERMINOLOGY
1
OPERATING THE LIFT GATE
2
OPERATION OF THE LIFT GATE
Before operating the lift, read and understand this decal, urgent warning decal and the owner’s manual.
Do not stand behind the lift gate while unfolding or using the platform.
To unfold the platform from the over-the-road position:
1.
Momentarily fold the gate. Push the fold and up switches at the same time, as to
2.
ensure the gate is fully folded.
To relieve tension on the auto lock, push the up switch (gate will go up), pull the
3.
4.
handle to release the auto lock.
Lower the platform by pushing the down switch so the ears are below the safety plate on the outer mast.
Push the unfold switch (gate will unfold).
To dock load:
1.
2.
To relieve the tension on the auto lock, push the up switch (gate will go up), pull the handle to release the auto lock.
Lower the gate until the ears on the platform rest on the stops of the outer mast.
To lower platform, use the down switch only.
To raise platform, use the up switch only.
Safe loading of platform:
1.
The cart stop or retention ramp must be in place whenever lifting or lowering a load. Also, see the urgent warning decal.
To fold platform:
1.
Raise the platform off the ground so that the ears are above the safety plate on
2.
the outer mast when platform folds.
Push the fold and up switch at the same time by using both hands. Platform will fold. Continue to raise the platform to the full up position, auto lock will latch.
3
3.
4.
HOW TO OPERATE THE HAND PUMP - GRAVITY DOWN
1.
2.
5.
Inside the power unit enclosure, turn the ball valve (plastic covered handle) 90° to the full open position. The handle will be inline with the valve body and hose when fully open.
Insert the handle into the pump and jack up. When the platform is completely up and against the stops, keep pumping and the platform will fold up. Continue to pump until the platform ears are tight against the outer mast.
Close the plastic covered ball valve handle.
Using the handle, slowly turn the valve located on the hand pump to let the platform lower until the platform ears go into the notch on the outer mast. Then close the valve.
Jack the platform up until the platform is completely up and locked in the over-theroad driving position.
3.
4.
HOW TO OPERATE THE HAND PUMP - POWER DOWN
1.
2.
5.
Inside power unit enclosure, open ball valves ( plastic covered handles turned in-line with valve body).
Insert hand pump handle into the hand pump and jack platform up to the full up position. Continue pumping to fold the platform up until the platform ears are tight against the outer mast.
Close the ball valves ( plastic covered handles turned 90° to valve body).
Use the handle to slowly turn the valve located on the hand pump counterclockwise to lower the platform until the platform ears go into the notch on the outer mast.
Close the valve on the hand pump.
Open the ball valve located on the reservoir tank only and then jack the platform up until the platform ears engage the auto-lock in the over-the-road driving position.
4
MAINTAINING THE LIFT GATE
5
RECOMMENDED HYDRAULIC OILS AND LUBRICATION
FOR LEYMAN LIFT GATES
Level 1 Normal Conditions
Manufacturer Type Temperature Range
Level 2
Chevron
Mobil
Shell
Exxon
Chevron
Mobil
Shell
Exxon
Mil
RYKON ISO-15 -15
°
F to +150
°
F
DTE-11 -15
°
F to +150
°
F
TELLUS-T15 -15
°
F to +150
°
F
UNIVIS N15 -15
°
F to +150
°
F
Cold Conditions
AVIATION-A
AERO-HFA
AERO FLUID #4
UNIVIS HVI 13
H-5606
-50
°
F to +80
°
F
-50
°
F to +80
°
F
-50
°
F to +80
°
F
-50
°
F to +80
°
F
-50
°
F to +80
°
F
LUBERCATION SPECIFICATIONS
Parts to Grease Use
Hinge Barrels & Fittings B.P. Products/ Wichita KS
Hinge Barrels
(center platform)
W.W. Grainger
Battery & Bowman
Electrical Components
Part # 60035-Multi Purpose
Grease # 35
Part # 6Y834-Needle Nose
Adapter for Grease Gun
Battery Terminal Protector
Part # 21948
6
10900 Kenwood Road
• Cincinnati, OH 45242
Ph: 513.891.6210
• Toll-Free: 866.539.6261 • Fax: 513.891. 4901
SAFETY AND PREVENTATIVE MAINTENANCE INSPECTION
FOLD-A-VADOR MODEL FDC-RM
Maintenance by Cycles
CUSTOMER:
LOCATION:
VEHICLE#:
√
= OK
2,000 4,000 8,000
LIFT GATE MODEL#: LIFT GATE SERIAL#:
2,000 4,000
2,000 4,000
8,000
8,000
A = ADJUSTED N = NOT APPLICABLE X = WRITE UP REPAIR
MOTOR - PUMP AND COMPONENTS
Check battery(ies) for water level and corrosion.
Check battery(ies) for proper charge level PROPER CHARGE LEVEL:
Check the voltage of battery(ies).
Check all wiring connections for corrosion and tightness.
Check solenoids for loose fittings and operation.
Check reservoir for correct amount of fluid (GRV DN – platform on ground, PWR DN – platform up)
Inspect fuse links and/or circuit breakers and replace if necessary.
Check the charge line or power line and the connections.
Remove and clean all pump solenoid cartridges.
Replace hydraulic fluid in reservoir.
Check and adjust the relief valve setting.
Check brushes and armature in motor. Replace if necessary.
Check amperage draw of motor (see owners manual for recommended amp draw)
LUBRICATION
Steam clean the inner and outer rails.
No lubrication should be required for the rollers or tracks.
LIFT GATE GENERAL/STRUCTURE INSPECTION
Open and close lift gate. Observe for correct operation
Raise and lower lift gate. If going up or down operation
Check inner and outer rails for impact damage. Repair if necessary
Check opening and closing cylinders for leaks. Repack or replace as necessary
Check up and down cylinder for leaks. Repack or replace cylinder
Inspect for broken and/or missing roll pins
Inspect for worn bushings/bearings in platforms & rollers. Replace as necessary
Steam clean gate. Repair any structural welds as needed
Repaint where needed and replace any worn or missing safety decals
SERVICED BY: ________________________________ DATE: ________________________________
Form May-03
TROUBLE-SHOOTING
8
TROUBLE SHOOTING CHART FOR POWER UNIT
PROBLEM
Platform will not go up or reach the floor of the vehicle.
Platform will not lower.
Platform does not go up smoothly.
PROBABLE CAUSE
1. Battery is low.
2. Slave line is disconnected or
connections are loose
(battery and motor).
3. Insufficient oil in power unit tank.
4. Poor switch connections.
REMEDY
1. Recharge the battery.
2. Connect the slave line properly.
3. Fill the power unit tank.
4. Clean and check switch connections.
1. Battery is low.
2. Poor switch connections.
1. Insufficient oil in power unit tank.
2. Air lock in hydraulic system.
3. Dirt or foreign material in guides.
4. Mechanical wear.
1. Recharge the battery.
2. Clean and check switch connections.
1. Fill tank.
2. Run platform to stop. Open up
bleeders in each ram while power unit
is running. Close bleeders and refill the tank.
3. Clean guides with steam and check for
excessive wear, obstructions, and burrs.
4. Replace worn parts.
Platform creeps down.
1. Hydraulic leak.
2. Ram seals failing.
3. Dirt under the ball of check valve, the
ball is pitted or worn or the spring is
weak.
Platform goes down slowly.
1. Excessive wear of mechanical
components.
2. Restriction in hydraulic system.
3. Incorrect hydraulic oil in system for
cold weather.
1. Check all hoses and fittings.
2. Replace ram seals.
3. Clean.
1. Insure free movement of all mechanical parts.
Platform goes up crooked.
1. Equalizer valve is out of adjustment.
2. Air trapped in one of the rams.
3. Tie bar is bent.
2. Check all hydraulic system
components.
3. Use Mobile Aero-HFA in cold weather.
1. Adjust equalizer valve.
2. Bleed air out of the ram.
3. Straighten the tie bar.
Platform comes down crooked.
1. Flow control not adjustable.
2. Dirt in hydraulic line at the bottom of
the ram.
3. Mechanical bind on one (1) side of gate.
4. Tie Bar is bent.
1. Replace flow control.
2. Clean hydraulic line and bleed ram.
3. Clean and inspect inner mast and
rollers. Check wear of parts
and replace if necessary.
4. Straighten tie bar.
9
Trouble Shooting Chart
Power Unit
Page 2
Gate will not lift the rated load.
Pump will not operate.
1. Hydraulic pump is worn.
2. Battery is too low.
1. Battery too low.
2. Electrical hookup to motor not making
contact.
3. Control switches are not making good
contact.
4. Maintenance Minder TM solenoid has
shut down the system due to low
voltage condition.
5.
Optional Maintenance Minder 2 controller has shut down the system due tolow voltage must maintain 8 volts minimum under load.
1. Change the pump.
2. Recharge the battery to full charge.
1. Recharge battery and check to be
sure that the slave line has a good
connection.
2. Clean connections and re-tighten.
3. Clean and check the connections.
4. Recharge battery. 9.5 volts must be
obtained.
5.
Use the "Last Lift Menu" date on screen to read maximum and minimum voltages, recharge battery.
10
ELECTRICAL DIAGRAM
GRAVITY DOWN
SPX/FENNER POWER UNIT (gold motor) w/ smart start solenoid (B/4 4/03)
11
ELECTRICAL DIAGRAM
GRAVITY DOWN
MONARCH POWER UNIT (black motor) w/ optional
MAINTENANCE MINDER 2 controller (after 4/03)
11a
ELECTRICAL DIAGRAM
POWER DOWN
SPX / FENNER POWER UNIT
(gold motor) w/ Smart Start solenoid (B/4 4/03)
12
ELECTRICAL DIAGRAM
POWER DOWN
MONARCH POWER
UNIT (black motor) w/ optional MAINTENANCE
MINDER 2 controller
(after 4/03)
12a
Note: The White wire and Black wire in the 16-5 cable (from the fold / unfold switch to the terminal strip) is not used.
WIRING DIAGRAM
WALK AROUND ELECTRICS
GRAVITY DOWN
13
WIRING DIAGRAM
WALK AROUND ELECTRICS
POWER DOWN
Note: The White wire and Black wire in the 16-5 cable (from the fold / unfold switch to the terminal strip) is not used.
14
SWITCH WIRING
GRAVITY DOWN
15
SWITCH WIRING
POWER DOWN
16
BATTERY HOOK UP
•
•
•
•
We recommend batteries with the following specifications:
12 Volt Deep Cycle
B.C.I. Group - Size 31
Terminal Type - TS
Cold Cranking Amps - 580
One Circuit Breaker
Wiring Diagram
FAILURE TO USE CORRECT BATTERIES WILL VOID WARRANTY
17
GROUNDING RECOMMENDATIONS FOR TRACTOR/TRAILER USING THE
MAINTENANCE MINDER SOLENOID
OR MAINTENANCE MINDER 2
CONTROLLER
POWER UNIT (-) Negative Charge Line
(+) Positive Charge Line
The Maintenance Minder
TM
solenoid requires a minimum of 9.5 volts in order for the FDC
TM
to operate.
Utilization of a single positive cable does not provide sufficient ground. Therefore, our recommendation for grounding tractor trailers with a FDC
TM
gate are as follows:
Two (2) cables one (1) positive and one (1) negative, both running to the tractor batteries.
The MAINTENANCE MNDER 2 controller (optional) requires that a minimumof 8 volts be maintained under load in order for the FDC to operate.
NOTE
The use of a battery charger as the sole power source to operate a FDC
TM
is unauthorized and will prevent the FDC
TM
from working properly. The lift gate must always be operated in conjunction with at least one (1)
12 volt heavy duty lift gate battery. A minimum of 9.5 volts must be maintained in order for the valves to operate.
18
MAINTENANCE MINDER START SWITCH
TROUBLE SHOOTING GUIDE
SYMPTOM
LED on start switch does not glow.
LED on start switch glows then goes off when attempting to operate the lift gate.
PROBABLE CAUSE
Poor ground
Poor ground connection
Battery voltage below 9 volts
Voltage at the start switch is below 9 volts
Faulty switch
Poor ground
CORRECTION
Check for proper ground, remove any paint or corrosion that may be inhibiting a good ground between the lug or the brown wire and the grounded surface.
Check for a loose connection at (Red Wire) the red wire.
Charge the battery.
Check the supply cable between the battery and the switch for loose connections and/or corrosion.
Replace the start switch.
Check the battery ground and the switch ground (brown wire) for good connections.
Battery voltage below 9 volts
Excessive voltage drop
Charge the battery.
Increase the battery cable size between along the battery cable and the Maintenance
Minder or connect the red wire directly to the battery.
19
Before 4/03
MAINTENANCE MINDER 2 OVERVIEW
•
•
•
Power unit is equipped with the Maintenance Minder 2 Controller. It will:
•
•
Automatically keep track of maintenance intervals, and warn the user when maintenance is due, based on the number of lifts
Record low voltage occurrences
Record high temperature faults
Record maximum run time faults, when a single operation exceeded the maximum continuous run time limit
Give helpful trouble-shooting information on MENU 4, “Last Lift Info”
FAULT CODES
A decal in the power unit enclosure lists the following signal codes for these faults:
1 BEEP
2 BEEPS
3 BEEPS
4 BEEPS
Service Fault (reached the number of lifts when maintenance is due)
Low Voltage Fault (check battery condition and power line connections)
Max. Time Fault (exceeded the maximum continuous run time allowed)
High Temperature Fault (unit will not run until motor cools)
All fault signals will be repeated THREE times. Controller will prevent power unit from operating during the time period when a fault signal is sounding (about 5 to 10 sec.). The controller is also equipped with an antidoorbelling feature, which prevents rapid ON / OFF operation of the power unit.
RESETTING after MAINTENANCE IS PERFORMED
To RESET the Maintenance Minder 2 after maintenance has been performed:
1) Go to MENU 2, hit “Enter”, and toggle down to the “Reset All Info” screen
2) Press the hidden RESET button under the Maintenance Minder 2 logo at top of faceplate
3) Follow the instructions on the screen regarding a second button, which must be pressed to complete the reset operation.
Page 20
MAINTENANCE MINDER 2 CONTROLLER MENUS
(Press MENU)
MENU 1 – LIFT GATE INFO
(Press ENTER, then ARROW DOWN for each item)
Model Number, Serial Number, Manufacture Date, Vehicle ID, Hardware Version,
Firmware Version, Software Version
(Press MENU and ARROW DOWN once)
MENU 2 – PERIOD INFO (data for the current maintenance period)
(Press ENTER, then ARROW DOWN for each item)
Number of Lifts (gives the number during this maintenance interval / and the set number when maintenance is due)
Motor ON (Total motor run time in minutes for this maintenance period)
Service Faults (number of times gate was operated while PAST the maintenance limit)
High Pressure Faults (not being used, no sensor available)
Max. Time Faults (times motor exceeded its maximum allowable continuous run time)
High Temperature Faults (times thermal switch in motor tripped, if switch provided)
Low Voltage Faults (times low voltage occurred)
Reset all Info (Reset data after performing maintenance, once maintenance limit is reached – instructions will flash on screen after limit reached)
(Press MENU and ARROW DOWN twice)
MENU 3 – LIFE TIME INFO (data for the total life time of the gate)
(Press ENTER, then ARROW DOWN for each item)
Same items will appear as under PERIOD INFO, except this is LIFE TIME data
Press MENU and ARROW DOWN three times)
MENU 4 – LAST LIFT INFO (Trouble Shooting Screen – it records data that occurred during the last lift made)
(Press ENTER, then ARROW DOWN for each item)
Supply Voltage (first voltage is the minimum voltage that occurred during the last lift – if below 6 volts gate will stop / second voltage is the supply voltage just before gate operation, must be at least
10 volts)
Motor ON Time (motor run time in seconds during last lift, gate will stop at 180 seconds)
Window Time (time in milliseconds during the last lift that the voltage dropped in between 6 and 8 volts – must not be any longer than 3 seconds or gate will stop)
Note: Controller has an anti-doorbelling feature. Motor will not operate if UP switch is toggled rapidly. This prevents welding of the start solenoid contacts.
Page 20A
GENERAL TIPS
LIFT GATE
1.
2.
3.
4.
This gate can run up or down uneven from the vehicle floor by 1" to 1-1/2" without damaging the mechanical workings on the gate.
The equalizer valve is only for adjusting the up stroke (while the gate is loaded).
The flow controls valves are for controlling the down stroke only. They should be cleaned and/or changed in sets.
Determining if the tie bar is bent:
5.
6.
Raise the platform to it’s full up position (level to the vehicle floor). Push the down switch. If the tie bar is bent, one side will always drop quicker than the other. If you have a bent tie bar, it is best to straighten it. See the maintenance manual for information on how to straighten the tie bar.
Before adjusting or attempting to fix any of the four items above, check the following first:
A.
Check the cylinder rods for lubrication. Dry rods or packings that are too tight
B.
may cause sticking or slow down the movement of the gate.
Check for bent inner mast.
C.
D.
Check to see if the back edge of the platform is hitting the floor level tube.
Check to see if the inner mast is rubbing on the outer mast. Some hitting is normal, but if it hinders the up/down operation, it must be lubricated.
Premature motor failure is almost always caused by low batteries.
Inadequate grounding is also a major reason for motor failure.
POWER UNIT
1.
2.
3.
4.
5.
6.
7.
If the motor runs and the gate doesn’t rise, you may have one of two problems:
1.
2.
The Emergency Hand Pump Valve is open (or partially open).
You have a bad pump.
To get the gate down, energize the two-way valve (white wire) and energize the four-way valve (red wire). The motor will not run in this operation.
To get the gate up, push one of the switches up. No valves must to be shifted. The
motor will run.
To unfold the platform, energize the two-way valve (orange wire). The motor will not run
in this operation.
To fold the platform, energize the four-way valve (red wire). The motor will run. You must push the fold switch and the up switch.
If the unit has an emergency hand pump and the gate goes up, hits the up stops and the platform starts to fold, the ball valve is open (or partially open). To correct this, close the ball valve.
The pressure setting for this gate is 2,000 PSI.
21
TO BLEED THE POWER FOLD CYLINDER
1. Unfold and lower the platform down to the ground.
2. Loosen the hose at the cylinder but do not remove completely.
3. Activate the pump (just long enough to produce an air free stream of oil from the hose).
4. Re-tighten the hose and check the oil level in the reservoir tank. Note: hold line while
tightening to ensure it does not twist.
5. Fold and unfold the platform several times. The platform should now fold and unfold
smoothly.
Clamps located inside guard on outer mast.
Clamp located inside guard on inner mast.
The electric line is routed along the hydraulic line to match the loop.
CHECK OIL LEVEL AFTER BLEEDING THE CYLINDER.
GRAVITY DOWN GATES- check with platform unfolded and on ground.
POWER DOWN GATES- check with platform unfolded and up at bed height.
22
BLEEDING THE LIFT CYLINDERS – GRAVITY DOWN
The FDCTM is shipped with the cylinders pre-filled with hydraulic fluid from the factory. If the procedures during the installation have been followed, it should not be necessary to bleed the cylinders. However, if the gate does not operate smoothly, the cylinders should be bled before making any other adjustments.
To Bleed the Lifting Cylinder – Bottom Side
1. Unfold and lower the platform to the full down position. CYLINDERS SHOULD BE
EXTENDED TO THEIR FULL LENGTH (GATE EXTENDED DOWN 56”) TO REMOVE AS
MUCH AIR FROM THE BOTTOM SIDE OF THE CYLINDER AS POSSIBLE. DEPENDING
ON FLOOR HEIGHT, IT MAY BE NECESSARY TO RAISE THE BODY OF THE VEHICLE
OR LOWER THE GATE PLATFORM INTO A PIT TO ACHIEVE MAXIMUM CYLINDER
EXTENSION.
2. Loosen the plugs in the back ports (ports closest to the vehicle body) but do not remove completely.
3. Activate the pump just long enough to produce an air-free stream of oil from the ports.
4. Re-tighten the plugs in the ports, lower the platform to the full down position, and check the oil level in the reservoir tank. The oil level should be approximately 1” from the top of the tank. Add oil if necessary.
To Bleed the Lifting Cylinder – Top Side
1. Not applicable for gravity down.
NOTE: FOR GRAVITY DOWN GATES, OIL LEVEL SHOULD ALWAYS BE CHECKED WITH THE
PLATFORM UNFOLDED AND LOWERED ALL THE WAY DOWN.
Rear Port:This port will allow ait out from the
lifting (bottom) side of the cylinder
Front Port: This port will have no oil for Gravity Down gates.
23
BLEEDING THE LIFT CYLINDERS – POWER DOWN
The FDCTM is shipped with the cylinders pre-filled with hydraulic fluid from the factory. If the procedures during the installation have been followed, it should not be necessary to bleed the cylinders. However, if the gate does not operate smoothly, the cylinders should be bled before making any other adjustments.
To Bleed the Lifting Cylinder – Bottom Side
1. Unfold and lower the platform to the full down position. CYLINDERS SHOULD BE
EXTENDED TO THEIR FULL LENGTH (GATE EXTENDED DOWN 56”) TO REMOVE AS
MUCH AIR FROM THE BOTTOM SIDE OF THE CYLINDER AS POSSIBLE. DEPENDING
ON FLOOR HEIGHT, IT MAY BE NECESSARY TO RAISE THE BODY OF THE VEHICLE
OR LOWER THE GATE PLATFORM INTO A PIT TO ACHIEVE MAXIMUM CYLINDER
EXTENSION.
2. Loosen the plugs in the back ports (ports closest to the vehicle body) but do not remove completely.
3. Activate the pump just long enough to produce an air-free stream of oil from the ports.
4. Re-tighten the plugs in the ports, raise the platform to the full up position, and check the oil level in the reservoir tank. The oil level should be approximately 1” from the top of the tank.
Add oil if necessary.
To Bleed the Lifting Cylinder – Top Side
1. Unfold and raise the platform to the full up position to remove as much air from the top side of the cylinder as possible.
2. Loosen the plugs in the front ports (ports furthest from the vehicle body) but do not remove completely.
3. Activate the pump just long enough to produce an air-free stream of oil from the ports.
4. Re-tighten the plugs in the ports, raise the platform to the full up position if not already there, and check the oil level in the reservoir tank. The oil level should be approximately 1” from the top of the tank. Add oil if necessary.
NOTE: FOR POWER DOWN GATES, OIL LEVEL SHOULD ALWAYS BE CHECKED WITH THE
PLATFORM UNFOLDED AND RAISED ALL THE WAY UP.
Rear Port:This port will allow ait out from the
lifting (bottom) side of the cylinder
Front Port: This port will allow air out from the power down (top) side of the cylinder.
23A
ADJUSTMENT OF THE EQUALIZER VALVE
g
NOTE g
Before making any adjustments, read the general tips page to be sure this is the problem.
Remember, adjusting the equalizer valve will control the up stroke only.
Locate the equalizer valve. Stand on the unfolded platform, look at the back of the truck/trailer.
The equalizer valve is about 4 inches below the floor line and in the center of the vehicle, or slightly to the left of center.
Back off the lock nut on the side that is running slow (lagging) turn the adjusting screw out 1/4 turn, lock nut and try. Repeat if necessary.
Although this can be done with no load on the platform, it normally helps to have a light load on the platform.
g
NOTE g
Turn the adjusting screw in = decreases the flow of oil
Turn the adjusting screw out = increases the flow of oil
24
STRAIGHTENING THE TIE BAR
g
NOTE g
Before bending the tie bar, read the general tips page to be sure this is the problem.
To check that you have a bent tie bar, raise the platform to the full “Up” position (level to the floor). Push the down switch, one side will always drop quicker than the other side. If one side is lower by more than one inch (1"), adjust the tie bar.
The tie bar is at the back edge of the platform. It is 1-1/2" wide, and holds the two inner masts together.
Acquire a piece of wood 4" X 4" X 2' long and place the wood between the tie bar and the up stop area near the floor line area. Caution! Check for cracked welds before preceding. Stand clear while performing this procedure.
g
NOTE g
If the curb side is dropping first, place the wood on the driver’s side. Run the gate up until the wood is secure, keep running the gate up another 6 to 8 inches. Let the gate down, remove the wood, cycle the lift gate to see if this has fixed the problem. If not, re-bend, except go up another inch or two. Keep repeating until corrected.
Sometimes, the power from the gate is not enough to correct this problem. If you have a hand pump, use it to take it up further. If you do not have a hand pump, use a floor jack and continue jacking the gate in an upward cycle.
STAND CLEAR
25
LUBRICATING THE ROLLER TRACKS
Lubrication of the roller tracks should not be necessary and is not desired for the rollers.
Do not grease between roller and Outer
Mast or roller and retaining angle.
26
Lightly grease inner mast along wear area if signs of rubbing are present.
PARTS REPLACEMENT
27
POWER UNIT PARTS
SPX/ FENNER POWER UNIT (GOLD
MOTOR)
FILTER P33616
"A" COIL AND VALVE ASSY.
WHITE AND BLUE WIRES
P33954
STARTER P33892A
"B" COIL AND VALVE ASSY.
ORANGE AND BLUE WIRES
P33956
BREATHER CAP P33667
O-RING P33960
SINGLE P/U TANK P33958
DUAL P/U TANK P33959
"C" COIL AND VALVE ASSY
RED AND BLUE WIRES
P33962
MOTOR P46340
NOT SHOWN
PUMP ASSY
P33652B
COMPLETE SINGLE POWER UNIT LESS FILTER P33952
COMPLETE DUAL POWER UNIT LESS FILTERS P33953
NOTE: THE POWER UNIT'S BLUE WIRES ARE GROUND WIRES.
REVERSING THESE WIRES WITH THE POSITIVE LEADS
WILL CAUSE PERMANENT DAMAGE TO THE COILS.
28
POWER UNIT PARTS
MONARCH POWER UNIT
(BLACK MOTOR)
COMPLETE SINGLE POWER UNIT LESS FILTER P33994
COMPLETE DUAL POWER UNIT LESS FILTERS P34012
28a
After 4/03
29
POWER FOLD ASSEMBLY
30
BA-805-297-1
BA-818-196
31
PLATFORM PINS AND BUSHINGS
BA-818-206
BA-818-205
32
POWER UNIT ASSEMBLY
GRAVITY DOWN
SPX/ FENNER (GOLD
MOTOR)
33
Before 4/03
POWER UNIT ASSEMBLY
GRAVITY DOWN
SPX/ FENNER (GOLD
MOTOR)
34
Before 4/03
POWER UNIT ASSEMBLY
GRAVITY DOWN
MONARCH (BLACK MOTOR)
34a
After 4/03
MONARCH (BLACK MOTOR)
POWER UNIT ASSEMBLY
GRAVITY DOWN
34b
POWER UNIT ASSEMBLY
POWER DOWN
SPX/ FENNER (GOLD MOTOR)
35
Before 4/03
POWER UNIT ASSEMBLY
POWER DOWN
SPX/ FENNER (GOLD MOTOR)
36
Before 4/03
POWER UNIT ASSEMBLY
POWER DOWN
36a
After 4/03
POWER UNIT ASSEMBLY
POWER DOWN
36b
After 4/03
HAND PUMP ASSEMBLY
GRAVITY DOWN
SPX/ FENNER (GOLD MOTOR)
37
Before 4/03
HAND PUMP ASSEMBLY
GRAVITY DOWN
MONARCH (BLACK MOTOR)
37b
After 4/03
HAND PUMP ASEMBLY
POWER DOWN
SPX/ FENNER (GOLD MOTOR)
38
Before 4/03
HAND PUMP ASEMBLY
POWER DOWN
MONARCH (BLACK MOTOR)
38a
After 4/03
INSTALLATION OF THE WARNING SIGNS AND DECALS
STREET SIDE DECALS
Warning Signs and Decals will be replaced at any time
FREE OF CHARGE
L
E
Y
M
A
N
O
H
I
I
N
N
A
C
I
N
C
T
I
39
INSTALLATION OF THE WARNING SIGNS AND DECALS
CURB SIDE DECALS
Warning Signs and Decals will be replaced at any time
FREE OF CHARGE
Will receive two of these decals. One goes on outer mast as marked, the other goes on the inner mast next to the switches.
40
Mount each decal next to the corresponding toggle switch.
INSTALLATION OF THE WARNING SIGNS AND DECALS
REAR OF VEHICLE DECALS
Warning Signs and Decals will be replaced at any time
FREE OF CHARGE
Will receive two of these decals
One goes on each side of the outer
41 mast.
NOTES
42

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Power-operated platform
- Fold-up design
- Various payload capacity
- Easy to operate
- Reliable and durable