advertisement
NEW
High-Accuracy Digital Contact Sensor
GT2 Series
GT2
Air Push Type
Air push models for stable operation with easy mounting.
Revolutionary technology enables high-accuracy measurement
[World’s First!]
2
The new GT2 Series provides even higher “error free” accuracy
Adopting the world's fi rst, ground-breaking scale-shot system, the new GT2 Series provides high-accuracy, without speed errors.
KEYENCE's long history of innovation and cutting edge technologies come together in the new GT2 Series.
Formed through a prism
LED parallel light illumination
Free from deformation
Quartz glass scale
Detachable Cable
Approx. 6 µs shutter speed
CMOS sensor
Advantages of the conventional scale method (pulse counting)
High-accuracy throughout the entire measurement range
Good temperature characteristics
Advantages of the conventional transformer method
No tracking errors
Absolute position detection
KEYENCE introduces new technology
World’s fi rst
Transmitter
Absolute value scale
CMOS sensor
The world’s fi rst, high-speed scale shot* system using a CMOS sensor that scans the absolute value glass scale incorporating different patterns depending on the position
* Shutter speed: Approx. 6 µs, Sampling interval: 1 ms
Highest accuracy in its class
Absolute system
Resolution
0.1
μm
0.004
Mil
Accuracy
1
μm
0.04
Mil
3
Tough and Rugged
[ Maintenance cost reduction ]
Long life
Detecting durability: 20 million times
*
Linear ball bearings are used for the spindle to ensure a long service life.
* GT2-H12 (L/K/KL), Typical
Strong rubber
Linear ball bearing used
Water resistant cable
IP67 enclosure rating
Even the connector meets the IP67 enclosure rating based on the IEC/JIS standards
* Except for the low stress type
Connector type
4
Strength against bending
Flexible free-cut robot cable
The sensor head cable uses a robot cable that withstands continuous bending.
Load (W): 250 g
Bend radius: 50 mm 1.97"
Bending rate: 30 times/minute
(1 time includes left to right to
Free cut: can be cut to length
R
90°
Withstands bending
20 million times without breaking (Typical usage)
W
The cable can be cut anywhere.
Free-cut
Easy Sensor Head Installation and Setup
[ Reduction in the number of installation/setup steps ]
Easy installation with a special bracket
Conventional method
GT2
Mounting made easy simply by drilling a
10 mm 0.39" hole.
A slotted jig must be prepared by the user.
Large indicators are convenient when setting up several units.
Flashing lights
The user can easily identify an operating sensor head.
Simple Tolerance Setting
[ Fewer steps for setup ]
First, set the reference.
Enter the tolerance value based on the master target to complete setup.
Example: Enter 0.010.0
A 0.01 mm
0.0004" tolerance range is automatically set.
Press the PRESET button to set to 0.
5
6
Easy Amplifi er Installation and Setup
[ Fewer steps for installation/setup ]
Select the best display unit according to the application
DIN-rail mount
Compact, panel mount
Large display panel mount
Pulse output
GT2-71N/71P
Easy mounting anywhere
GT2-75N/75P
For mounting in a nearby enclosure
Note: For the DIN-rail mounting type, a connector type and an analog output type are also available.
GT2-100N/100P
Easy-to-see large display
Features of the large display type
Easy operation with large display and large buttons
Double the size of a standard display
[Character height:
14 mm 0.55" ]
Large display
GT2-71D
For outputting position data as pulses
A single unit can connect several sensor heads
(11 heads max.).
Power supply terminal block
Standard I/O (20-pin MIL connector, male)
Easy preset operation
Large button
The selected
ID number lights in red.
W: 159.5 mm
6.28"
H: 79.8 mm
3.14"
Easy selection with the dedicated button
Sensor head selection button
Easy viewing of each individual head’s OK/NG and connection status. (OK/NG status is indicated by red or green, connection status is indicated by a blinking LED.)
Expansion board I/O
(30-pin MIL connector, male)
Communication unit connection port
Installing the expansion board
The expansion board allows for connection of up to 11 sensor heads.
Features of the pulse output (line driver output) type
Outputs the spindle position data
Pulse frequency selection
[10/50/100/500 kHz]
The maximum pulse frequency can be selected according to the input device. The absolute detection ensures accurate position data output to an external device without tracking errors even when a slow pulse frequency is selected.
Pulse output amplifi er unit
GT2-71D
Increment/decrement direction
Resolution
Pulse width
All position data can be output together.
The absolute detection allows the output of all pulses from the origin to the measurement point without origin return at power-up. Moreover, the operation is free from tracking errors.
Total cost reduction
[ Simplifi ed confi guration eliminates the need for analog I/O cards and tedious PLC programming ]
Analog I/O card not necessary
No additional equipment required
Forget about the tedious PLC programming that existing LVDT’s required, the GT2 Series does everything automatically. In addition, the user can save money by eliminating the analog I/O card from the budget.
Conventional Method
Diffi cult and time consuming way:
Done
Display Analog card PLC programming
GT2 Solution
Easy way:
Done
Easy way:
Done
Push-button setup
HH, HI, GO, LO, LL discrete outputs
Featuring 5 digital comparator outputs (HH, HI, GO, LO and LL), the GT2 Series can be set up in minutes, not hours.
Push-button calibration will leave the user wondering why they hadn’t switched to the GT2 Series sooner.
HH
HI
GO
LO
LL
Quickly select from up to 4 sets of HH/HI/LO/LL limits
Simple product changeover
Using channel select inputs on the GT2 Series, users can easily toggle between up to 4 different sets of HH/HI/LO/LL limits, skipping the extra PLC programming.
7
8
Detection of Jam Conditions
[ Current condition check ]
Sensor defect detection
Equipment status check displayed by a bar indicator
Maintenance needed
HI Limit
Normal
Maintenance needed
Safe detection
LO Limit
Fully extended
Jammed
The sensor outputs in the event of a jam when the sensor head is not fully extended.
In actual operation, it is diffi cult to read a displayed value when it changes quickly. With the bar indicator the equipment status can be easily read without reading a displayed value.
Calculations made simple
[ Fewer steps for setup ]
When several amplifi ers are connected, the GT2 Series can do automatic calculation simply by selecting a calculation mode.
Thickness
[Shaft diameter measurement]
Positioning the target between two sensor heads will display the outer diameter.
Main unit Expansion unit
Calculation result
Degree of fl atness
Reference difference
[Flatness check]
By subtracting the minimum value from the maximum value the fl atness will be displayed.
Main unit
Expansion unit
Expansion unit
Expansion unit
Maximum value
Minimum value
Calculation result
[Determining pin height]
The height difference of a reference value can be displayed by subtracting the value of the main unit (reference) from the value of the Expansion unit.
Expansion unit Main unit
Calculation result
Versatile detection modes support all applications
Single head
STD P-H B-H P-P
Multiple heads/when additional amplifi er units are installed (Application modes)
Maximum Minimum
Degree of fl atness
Average
Reference difference
Twist Warpage Thickness
Standard Peak hold Bottom hold Peak to peak
* For details regarding the calculation modes, refer to P.30.
Air push type extends the spindle and measures.
[ Easy to set up and saves space. ]
The air push type is part of the high-accuracy digital sensor GT2 Series.
A mechanism to move the sensor head is not necessary since it is possible to measure with a fi xed sensor head, saving space and reducing labor.
Jigs and mechanisms to move the sensor are no longer necessary.
Standard type
Linear guide
Dividing jig
Stopper
Air push type
Measuring range
50
mm
1.97"
Measuring range
Measuring range
32
1.26"
mm
Measuring range
12
mm
0.47"
GT2-A32
Accuracy: 3 µm 0.12 Mil (p-p)
12
mm
0.47"
GT2-A12
General purpose type
Accuracy: 2 µm 0.08 Mil (p-p)
GT2-A12K
High-accuracy type
Accuracy: 1 µm 0.04 Mil (p-p)
GT2-A50
Accuracy: 3.5 µm 0.14 Mil (p-p)
All jigs unnecessary.
A complex jig is not necessary since there is no sensor head movement. In addition, errors in accuracy due to jigs have been eliminated.
Installation is quick and easy.
A dividing jig is unnecessary.
Air is supplied.
Dedicated installation metal fi ttings.
Only needs a ø10 mm
ø0.39" hole. *
1
ø4 mm
ø0.16" outside diameter air tube.
Point 1
Spindle compressed in its usual state
GT2 Conventional spindle is usually stretched damag e
Point 2
Measuring force is unaffected by the amount of air pressure.
*1 For the 32 mm 1.26" and 50 mm 1.97" type, open a ø14 mm ø0.55" hole.
With the GT2, the spindle moves to the origin when it is not being supplied with air. Even if there is a problem or a condition arises where air is not being supplied, it is safe.
Due to the pressure free construction where air pressure is not directly applied to measurement parts, it is also safe to use with easily damaged workpieces.
9
10
Versatile detection modes support all applications
Single head
STD P-H B-H P-P
Standard Peak hold Bottom hold Peak to peak
Multiple heads
Maximum Minimum
Degree of fl atness
Average
Reference difference
Twist Warpage Thickness
Measurement of defects in a press fi t
Packing insertion check
Confi rms that targets are properly seated.
Shaft diameter measurement
Board warpage detection
Confi rms if the workpiece warpage meets the acceptable limits.
Detecting twist
Judges if the workpiece twisting falls within acceptable limits.
Flatness measurement of an engine block
Thickness measurement of a liquid crystal substrate
Parallel measurement of a wafer
Thermal expansion measurement of a machine tool
Thickness measurement of a steel plate
Warp measurement of a mechanical chassis
Volume measurement of a cam lift
Measurement of a transmission mount
Detection of crank shaft runout
11
How to select a GT2 Series sensor
Follow the steps below to select the GT2 Series sensor best suited to your operating environment from the wide range of units and accessories.
step
1 Sensor head
Standard Type step
1
Sensor head
step
2
Sensor head cable
step
3
Mounting bracket
step
4 step
5
Display unit
(Amplifi er unit)
Display unit options
step
6
Contact
step
7 step
8
Communication unit
Communication unit options
GT2 Series LINE-UP
step
2 Sensor head cable
Air push Type
NEW
step
5
Display unit options
12 mm 0.47" range
High-accuracy sensor head
GT2-H12K
12 mm 0.47" range
High-accuracy, low stress sensor head
GT2-H12KL step
3 Mounting bracket
12 mm 0.47" range
High-accuracy sensor head
12 mm 0.47" range
High-accuracy, low stress sensor head
GT2-A12K GT2-A12KL step
4 Display unit step
6 Contact
DIN-rail mount type
Amplifi er unit
GT2-71N / 71P step
7
Communication unit
BCD Output unit
DL-RB1A
12 mm 0.47" range
General-purpose sensor head
GT2-H12
12 mm 0.47" range
General-purpose, low stress sensor head
GT2-H12L
12 mm 0.47" range
General-purpose sensor head
GT2-A12
12 mm 0.47" range
General-purpose, low stress sensor head
GT2-A12L
Panel mount type
Compact amplifi er unit
GT2-75N / 75P
RS-232C
Communication unit
DL-RS1A
Panel mount type
Large display amplifi er unit
GT2-100N / 100P step
8 Communication unit options
DIN-rail mount type
Pulse output amplifi er unit
GT2-71D
32 mm 1.26" range
General-purpose sensor head
GT2-H32
32 mm 1.26" range
General-purpose, low stress sensor head
GT2-H32L
32 mm 1.26" range
General-purpose sensor head
GT2-A32
12
50 mm 1.97" range
General-purpose sensor head
GT2-H50
50 mm 1.97" range
General-purpose sensor head
GT2-A50
How to select a GT2 Series
step step
1
First, select a sensor head.
Required
The sensor head is determined by the measuring range, force, and accuracy.
Standard Type
Commonly used type
12 mm
0.47"
range
For 20 µm 0.79 Mil or less tolerance differentiation
High-accuracy Type
Resolution: 0.1 µm 0.004 Mil
Accuracy: 1 µm 0.04 Mil (P-P)
High-accuracy type sensor head
GT2-H12K
High-accuracy / Low stress type sensor head
GT2-H12KL
Low stress type
When particularly highaccuracy is not required
General-purpose Type
Resolution: 0.5 µm 0.02 Mil
Accuracy: 2 µm 0.08 Mil (P-P)
General-purpose type sensor head
GT2-H12
General-purpose / Low stress type sensor head
GT2-H12L
For a wider measuring range
32 mm
1.26"
range
Resolution: 0.5 µm 0.02 Mil
Accuracy: 3 µm 0.12 Mil (P-P)
General-purpose type sensor head
GT2-H32
General-purpose / Low stress type sensor head
GT2-H32L
Low stress type
For a larger target
50 mm
1.97"
range
Resolution: 0.5 µm 0.02 Mil
Accuracy: 3.5 µm 0.14 Mil (P-P)
General-purpose type sensor head
GT2-H50
The low stress type is not available for the 50 mm 1.97" range sensor head.
Low stress type
The low stress type does not require a dust boot.
What is the low stress type?
The low stress type uses a low repulsion force spring to reduce the pressure on the target. When using a target that can be easily deformed or damaged, select this type.
Measuring range
Type of accuracy Measuring force
12 mm 0.47"
32 mm 1.26"
50 mm 1.97"
High-accuracy
General-purpose
General-purpose
* Value at center of measuring range.
Standard
Low stress
Standard
Low stress
Standard
Low stress
Standard
Resolution
0.1 µm
0.5 µm
0.004 Mil
0.02 Mil
Accuracy
1 µm
2 µm
0.04 Mil
0.08 Mil
0.5 µm 0.02 Mil
3 µm 0.12 Mil
3.5 µm 0.14 Mil
Downward mounting
Measuring force*
Side mounting
1.0 N
0.4 N
0.9 N
0.3 N
1.0 N
0.4 N
2.1 N
1.2 N
3.2 N
0.9 N
0.3 N
1.8 N
0.9 N
2.8 N
Upward mounting
0.8 N
0.2 N
0.8 N
0.2 N
1.5 N
0.6 N
2.4 N
Model
GT2-H12K
GT2-H12KL
GT2-H12
GT2-H12L
GT2-H32
GT2-H32L
GT2-H50
Dust boot (optional accessory for replacement)
Appearance Applicable sensor head
GT2-H12
GT2-H12K
GT2-H32
GT2-H50
Model
OP-84332
OP-84459
OP-84460
13
14
How to select a GT2 Series
step
Air Push Type
NEW
Commonly used type
12 mm
0.47"
range
For 20 µm 0.79 Mil or less tolerance differentiation
High-accuracy Type
Resolution: 0.1 µm 0.004 Mil
Accuracy: 1 µm 0.04 Mil (P-P)
High-accuracy type sensor head
GT2-A12K
High-accuracy / Low stress type sensor head
GT2-A12KL
Low stress type
When particularly highaccuracy is not required
General-purpose Type
Resolution: 0.5 µm 0.02 Mil
Accuracy: 2 µm 0.08 Mil (P-P)
General-purpose type sensor head
GT2-A12
General-purpose / Low stress type sensor head
GT2-A12L
For a wider measuring range
32 mm
1.26"
range
Resolution: 0.5 µm 0.02 Mil
Accuracy: 3 µm 0.12 Mil (P-P)
General-purpose type sensor head
GT2-A32
The low stress type is not available for the 32 mm 1.26" range sensor head.
For a larger target
50 mm
1.97"
range
Resolution: 0.5 µm 0.02 Mil
Accuracy: 3.5 µm 0.14 Mil (P-P)
General-purpose type sensor head
GT2-A50
The low stress type is not available for the 50 mm 1.97" range sensor head.
Low stress type
Measuring range
Type of accuracy Measuring force
High-accuracy
12 mm 0.47"
General-purpose
32 mm 1.26"
50 mm 1.97"
General-purpose
* Value at center of measuring range.
Standard
Low stress
Standard
Low stress
Standard
Standard
Resolution
0.1 µm 0.004 Mil
Accuracy
1 µm 0.04 Mil
0.5 µm 0.02 Mil
0.5 µm 0.02 Mil
2 µm 0.08 Mil
3 µm 0.12 Mil
3.5 µm 0.14 Mil
Downward mounting
Measuring force*
Side mounting
1.2 N
0.4 N
1.2 N
1.1 N
0.3 N
1.1 N
0.4 N
2.1 N
3.2 N
0.3 N
1.8 N
2.8 N
Upward mounting
1.0 N
0.2 N
1.0 N
0.2 N
1.5 N
2.4 N
Model
GT2-A12K
GT2-A12KL
GT2-A12
GT2-A12L
GT2-A32
GT2-A50
Adjustable spindle speed
The speed controller (optional) allows the spindle movement speed to be adjusted.
Speed controller
OP-82133
step step
2
Select a sensor head cable
Required
Select the sensor head cable according to installation conditions and the distance between the sensor head and the display unit (amplifi er).
The L-shaped type can be used for the 12 mm 0.47" range sensor head (GT2-H12/A12) only.
Cable connection
Commonly used type
Straight Type
Cable connection
For space-saving installation
L-shaped Type
This connector does not rotate.
It is fi xed in the direction as shown in the photo (left).
Type
Straight
L-shaped
Applicable to
12 mm 0.47" range type only
Appearance Cable length
2 m 6.6'
5 m 16.4'
10 m 32.8'
20 m 65.6'
2 m 6.6'
5 m 16.4'
10 m 32.8'
20 m 65.6'
Model
GT2-CH2M
GT2-CH5M
GT2-CH10M
GT2-CH20M
GT2-CHL2M
GT2-CHL5M
GT2-CHL10M
GT2-CHL20M
Weight
Approx. 80 g
Approx. 190 g
Approx. 360 g
Approx. 680 g
Approx. 80 g
Approx. 190 g
Approx. 360 g
Approx. 680 g
The cable can be freely cut. If the cable is cut, a connector (OP-84338) is required to connect to the display unit (amplifi er).
This connector is required if the cable is cut.
The cable can be cut anywhere.
Connector used to connect to a display
unit (2 pcs.) OP-84338
step
3
Select mounting brackets as required.
Select a mounting bracket depending on the sensor head mounting method.
For GT2 12 mm
0.47"
range models
Commonly used type
Mounting Bracket A
OP-76874
Vibration resistant, Reinforced holding force
Mounting Bracket C
OP-84396
After drilling a ø10 mm ø0.39" hole, insert the sensor head through the hole, and fasten it.
For side mounting
Mounting Bracket B
Horizontally mounts the sensor head.
OP-76875
For GT2 32 mm
1.26"
and 50 mm
1.97"
range models
Vibration resistant, Reinforced holding force
Mounting Bracket D
OP-84327
After drilling a ø14 mm ø0.55" hole, insert the sensor head through the hole and fasten it.
* The mounting method is the same as mounting brackets A and C.
* When using the GT2-H32L with its contact probe directing upward, use the mounting holes in the sensor housing.
15
16
How to select a GT2 Series
step step
4
Next, select a display unit (amplifi er).
Required
After selecting a display unit depending on the mounting method, select optional accessories as required.
Easy installation in any place
DIN-rail Mount Type
Commonly used type
Loose wire type
Easy installation/replacement
Connector type
Connecting additional expansion units
Use the connector on the side of the unit.
Main unit
Expansion unit
GT2-71N/71P GT2-71CN/71CP
Connector
To connect an additional unit, purchase the optional end unit (OP-26751).
For each main unit, up to 14 expansion units can be connected.
When several units are connected, a power supply cable is not required for the expansion units. The GT2 Series can be connected with the GT Series. However, the maximum number of connectable units is 10 units
(including main unit).
Unit expansion is not possible for the
GT2-71D.
Loose wire
Connector*
Type
Main unit
Standard
Expansion unit
Pulse output
Standard
Analog
Standard
Main unit
Expansion unit
Model
NPN output PNP output Line driver output
GT2-71N GT2-71P
–
GT2-72N
–
GT2-72CN
GT2-72P
–
GT2-71CN GT2-71CP
GT2-71MCN GT2-71MCP
GT2-72CP
GT2-71D
–
* When the connector type amplifi er unit is used, an optional socket cable should be purchased separately (See the next page.).
The analog output type amplifi er unit provides three discrete outputs.
Installation on easy-to-see places
Panel Mount Type
Commonly used type
Compact type
Easy-to-see display for easier operation
Large display type
Connecting additional main and expansion units
[Compact type only]
Connect using the cable supplied with the expansion unit.
Expansion cable
To connect additional units, place the main unit in the top position and connect the expansion units below
(vertically).
* For horizontal installation, the optional expansion cable
(OP-35361, 300 mm 11.81" ) is required. For details, refer to the description in the option list.
For the compact type amplifi er unit, up to 14 expansion units can be connected to one main unit without providing power supply cables individually. The expansion connection can include the GT Series, however, the maximum number of connectable units is limited to 10 including the main unit.
GT2-75N/75P
W: 66 mm 2.60" H: 23.9 mm 0.94"
GT2-100N/100P
W: 159.5 mm 6.28" H: 79.8 mm 3.14"
Compact
Type
Main unit
Expansion unit
Model
NPN output PNP output
GT2-75N GT2-75P
GT2-76N
GT2-100N
GT2-76P
GT2-100P Large display*
* When these amplifi er units are not mounted to a panel, an optional mounting bracket should be purchased separately (See the next page.).
A single unit of the large display type can connect two sensor heads.
When the optional expansion boards are used, up to 11 sensor heads can be connected. For the details of the expansion board, see the next page.
step step
5
Select the optional accessories for the display unit as required.
Select the optional accessories according to the display unit selected in Step 4.
Optional accessories for the GT2-71/72
(DIN-rail mount)
Description Type
For installation without a DIN-rail
Mounting Bracket for DIN-rail mount Type Display unit
(optional accessory for main unit)
The amplifi er can be mounted without using a
DIN-rail.
Amplifi er mounting bracket
End unit
End unit
Required for connecting additional units
End unit
(Optional)
To connect an additional expansion unit, use the end units to secure the display units on both ends. When connecting additional units, be sure to use the end units. (2 pcs.)
Required when the connector type is used
Socket cable
2 m 6.6' /10 m 32.8'
(Optional)
Used to connect the connector type display unit.
Since the amplifi er unit does not include the socket cable, it must be purchased separately.
Model
OP-76877
OP-26751
GT2-CA2M
(2 m 6.6' )
GT2-CA10M
(10 m 32.8' )
Optional accessories for the GT2-75/76
(panel mount, compact)
Description Type
Standard equipment
Panel mounting bracket
(Included in panel mount type amplifi er)
The panel mounting bracket is included in the panel mount type amplifi er.
If the supplied bracket is lost or damaged, order a new bracket.
If the standard cable length is not enough
Expansion cable:
300 mm 11.81"
(Optional)
Extension cable used for panel mount type amplifi er.
Use this cable if the standard 50 mm 1.97" cable is not long enough.
Up to 4 extension cables can be used at once. However, if an extension cable is used, the number of expansion units that can be connected to a single main unit is limited to 4 units.
Model
OP-84394
OP-35361
Optional accessories for the GT2-100
(panel mount, large display)
Type
To connect three or more sensor heads
Expansion board
For GT2-100N
(Optional)
For GT2-100P
(Optional)
Description
Installing this expansion board into the GT2-
100 allows you to connect more than two sensor heads. Since one expansion board allows connection of one to three sensor heads, the maximum of 11 sensor heads can be connected in total.
No. of sensor heads
1 or 2
3 to 5
6 to 8
9 to 11
No. of expansion boards
None
1
2
3
Model
GT2-E3N
(NPN)
GT2-E3P
(PNP)
To install the GT2-100 on a workbench, etc.
Mounting bracket
(Optional)
I/O connector
20-pin MIL connector
(for the amplifi er unit, optional)
30-pin MIL connector
(for the expansion board, optional)
Contact for maintenance work
(Optional)
Small diameter contact
(Optional)
Special crimping tool
(Optional)
When the amplifi er unit is not mounted to a panel, use this mounting bracket to secure it.
A set of connector and contacts (for AWG 24 to 22).
The cable should be prepared by the user.
For AWG 24 to 22, Package of 200
For AWG 28 to 26, Package of 200
Use this tool to crimp the contact.
Secure the amplifi er unit with M4 screws.
OP-84331
OP-22185
(20-pin)
OP-84456
(30-pin)
OP-22186
OP-30594
OP-21734
17
18
How to select a GT2 Series
step step
6
Select a contact as needed.
The standard type and carbide type contacts are included in the GT2-H12 (L) / H32 (L) / H50 / A12 (L) / A32 / A50 and the GT2-H12K (L) /
A12K (L) respectively, as standard equipment. Other types of contacts are optionally available. Select optional contacts as required.
For standard measurement
Standard
OP-77678
Standard equipment of generalpurpose type sensor head
GT2-H12 (L) / H32 (L) / H50 /
A12 (L) / A32 / A50
For moving targets
Roller
(Optional)
OP-77680
The roller smoothly detects moving targets.
For measurement in narrow spaces
Needle
(Optional)
OP-77681
The needle contact is made of super-tough tungsten alloy.
Made from a carbide alloy – For high-accuracy measurement
Super-tough
OP-77682
Standard equipment of high-accuracy type sensor head GT2-H12K (L) / A12K (L)
To prevent damage to target
Fluorocarbon Resin
(Optional)
OP-80228
Made from material that is unlikely to damage the target’s surface.
For measurement at several points with small targets
Offset
(Optional)
OP-77683
Detecting points can be added in narrow range.
For targets with curved surfaces
Flat Plate
(Optional)
OP-77679
Ignore the contours of a target with a curved surface.
Electrically insulated from the target
Ceramic
(Optional)
OP-81970
Ceramic is used for the ball of the contact tip.
For 12.2 mm 0.48" spindle extension
Spacer
(Optional)
OP-77684
When lifting a spindle by hand
Lift lever
(Optional)
OP-84397 step
7
Select a communication unit as needed.
A communication unit is required to extract numerical data from the GT2 Series to an external device. With a single unit, data from up to 15
GT2 Series units can be extracted.
To extract BCD data
BCD Output
Unit
Detection data can be read from a specifi ed sensor amplifi er via an external device such as a PLC.
For RS-232C communication
RS-232C
Communication
Unit
Sensor amplifi er detection data, settings, and calculation results from several GT units can be read and amplifi er settings can be written via an external device such as a PLC or PC.
DATA
DATA
Reading
BCD output unit
DL-RB1A
Writing
Reading
RS-232C communication unit
DL-RS1A
Reading
Programmable controller
Programmable controller
PC
step step
8
Select the optional accessories for the communication unit as necessary.
Select the optional accessories according to the type of the communication unit selected in Step 7.
Optional accessories common to the DL-RB1A and DL-RS1A
Type Description Model
To install the unit without using a DIN-rail
Mounting bracket
The communication unit can be mounted without using a DIN-rail.
OP-60412
To connect the unit to the panel mount type display unit
Expansion cable:
300 mm 11.81"
(Optional)
Although the DL Series is designed for DIN-rail mounting only, the optional expansion cable
(OP-35361, 300 mm 11.81" )
Main unit
Expansion unit
Expansion unit enables communication with the panel mount type amplifi er unit
(compact/large display).
DL
Expansion cable
(300 mm 11.81" )
OP-35361
OP-35361
Optional accessories for the DL-RB1A
Type Description
I/O connector
34-pin vertical MIL connector
(Optional)
[40 contacts for AWG 24 to 22 included]
A set of connector and contacts (for AWG 24 to 22).
The cable should be prepared by the user.
I/O connector
34-pin slanting MIL connector
(Optional)
[40 contacts for AWG 24 to 22 and a cable tie included]
A set of connector and contacts (for AWG 24 to 22).
The cable should be prepared by the user.
Special crimping tool
(Optional)
Contact for maintenance work
(Optional)
Small diameter contact
(Optional)
Use this tool to crimp the contact.
For AWG 24 to 22, Package of 200
For AWG 28 to 26, Package of 200
Model
OP-23139
OP-42224
OP-21734
OP-22186
OP-30594
Optional accessories for the DL-RS1A
Type Description
D-sub 9-pin connector-to-loose wires cable
(5 m 16.4' , optional)
This cable can be used to connect the DL-RS1A to a personal computer or other serial device.
Model
OP-81283
19
Specifi cations
❙
Sensor heads for the GT2 Standard Type
Model GT2-H12K
Type
GT2-H12KL GT2-H12 GT2-H12L
Standard / Low stress (L) type (Sensor head for 12 mm 0.47" )
GT2-H32 GT2-H32L GT2-H50
Standard / Low stress (L) type
(Sensor head for 32 mm 1.26" /50 mm 1.97" range)
Appearance
Detection system
Measuring range
Resolution
Accuracy (20°C 68°F )
Measuring force * 1
Downward mounting
Side mounting
Upward mounting
Mechanical response
Probe
Operation indicator
Environmental resistance
Enclosure rating
Ambient temperature
Relative humidity
Vibration
Sensor head cable
Main body
Materials
Contact
Weight (excluding cable)
Accessories
1.0 N
0.9 N
Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)
12 mm 0.47" 32 mm 1.26"
0.1 µm 0.004 Mil
1 µm 0.04 Mil (p-p)
0.4 N
0.3 N
2 µm
1.0 N
0.9 N
0.08 Mil (p-p)
0.4 N
0.3 N
0.5 µm 0.02 Mil
3 µm
2.1 N
1.8 N
0.12 Mil (p-p)
1.2 N
0.9 N
0.8 N
10 Hz
Carbide ball ø3
0.2 N
4 Hz
IP67
0.8 N
10 Hz
0.2 N
4 Hz
1.5 N
6 Hz
Steel ball ø3
0.6 N
5 Hz
– IP67
2-color LED (red, green)
– IP67 –
-10 to +55°C 14 to 131°F
35 to 85% RH (No condensation)
10 to 55 Hz, 1.5 mm 0.06" double amplitude, 2 hours in each of X, Y, and Z directions
Optional (M8 connector)
Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR * 2
TYPE304 Stainless steel, super-tough tungsten alloy
Approx. 95 g
TYPE304, 440C Stainless steel
Approx. 270 g
Refer to the instruction manual.
*1 Value at center of measuring range.
*2 A dust boot is not provided with the GT2-H12KL, the GT2-H12L or the GT2-H32L.
❙
Sensor heads for the GT2 Air Push Type
Model
NEW
GT2-A12K
Type
NEW
GT2-A12KL
NEW
GT2-A12
NEW
GT2-A12L
Standard / Low stress (L) type (Sensor head for 12 mm 0.47" )
50 mm 1.97"
3.5 µm 0.14 Mil (p-p)
3.2 N
2.8 N
2.4 N
7 Hz
IP67
Approx. 320 g
NEW
GT2-A32
NEW
GT2-A50
Standard type (Sensor head for 32 mm 1.26" /50 mm 1.97" range)
Appearance
20
Detection system
Measuring range
Resolution
Accuracy (20°C 68°F ) * 1
Measuring force * 2
Upward mounting
Operation indicator
Applied pressure range
Pressure resistance
Environmental resistance
Downward mounting
Side mounting
Enclosure rating
Ambient temperature
Relative humidity
Vibration * 4
Sensor head cable
Materials
Main body
Dust boot
Contact * 5
1.2 N
1.1 N
Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)
12 mm 0.47" 32 mm 1.26"
0.1 µm 0.004 Mil
1 µm 0.04 Mil (p-p)
0.4 N
0.3 N
1.2 N
2 µm 0.08 Mil (p-p)
0.4 N
0.5 µm 0.02 Mil
3 µm 0.12 Mil (p-p)
2.1 N
1.8 N
1.0 N 0.2 N
1.1 N 0.3 N
1.0 N 0.2 N
2-color LED (red, green)
0.25 to 0.5 MPa
1.5 N
IP67 *
3
–
1.0 MPa
IP67 *
3
0 to 55°C 32 to 131°F
– IP67 *
3
35 to 85% RH (No condensation)
10 to 55 Hz, 1.5 mm 0.06" double amplitude, 2 hours in each of X, Y, and Z directions
Optional (M8 connector)
Main body case: Zinc die-casting; Cylinder part: Aluminium alloy;
Air joint resin part: Polyacetal; Air joint metal part: Brass nickel plating; Indicator: Polyarylate
– NBR – NBR NBR
TYPE304 Stainless steel, super-tough tungsten alloy
Approx. 145 g
TYPE304, 440C Stainless steel
Approx. 340 g
Refer to the instruction manual.
50 mm 1.97"
3.5 µm 0.14 Mil (p-p)
3.2 N
2.8 N
2.4 N
IP67 *
NBR
3
Approx. 405 g
Weight (excluding cable)
Accessories
*1 Value when ambient temperature is 20°C 68°F
*2 Value at center of measuring range.
Please note that the measurement force changes depending on the installation state of the dust boots.
*3 Make sure the air tube is connected to the air exhaust joint and that no foreign materials enter inside from the joint.
*4 In the case where a mounting bracket D is used with GT2-A32 and GT2-A50, the double amplitude becomes 0.75 mm 0.03" .
*5 The contact is included with the sensor.
❙
DIN-rail mount type amplifi er unit (For the pulse output type, see page 19.)
Model
NPN output
PNP output
Mounting method
Type
Main unit / Expansion unit * 1
GT2-71N
GT2-71P
GT2-72N
GT2-72P
Standard loose wire type
Main unit Expansion unit
GT2-71CN
GT2-71CP
GT2-72CN
GT2-72CP
DIN-rail mount
Standard connector type
Main unit Expansion unit
Appearance
GT2-71MCN
GT2-71MCP
Analog output, connector type
Main unit
Power supply voltage * 1
Power consumption * 2
Normal
Power saving (Eco)
Display power
Measured value display
Other displays
Display range
Display resolution
Sampling rate
Timing input
Control input
Preset input
Reset input
Bank input
Control output
HH / High / Go /
Low / LL
Analog output
Response time
Ambient temperature
Environmental resistance
Relative humidity
Vibration
Materials
Weight
Accessories
10 to 30 VDC, including 10% ripple (P-P) 20 to 30 VDC, including 10% ripple (P-P)
2200 mW max. (30 V, 73.3 mA max.)
1700 mW max. (30 V, 56.7 mA max.)
2700 mW max. (30 V, 90 mA max.)
2200 mW max. (30 V, 73.3 mA max.)
6 + 1/2-digit 7-segment LED (red)
2-color, 13-level bar LED display (red, green), indicators (red, green)
-199.999.9 to 199.999.9
0.1 µm 0.004 Mil
1000 times/sec.
Input time: 2 ms min.
Input time: 20 ms min.
NPN/PNP open collector, Applicable current: 50 mA,
Maximum applicable voltage (NPN: 40 V, PNP: 30 V)
Residual voltage at ON: 1 V max. * N.O./N.C switchable
(GT2-71MCN/71MCP: HH and LL are not available.)
– hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s
-10 to +50°C 14 to 122°F (GT2-71MCN/71MCP: -10 to +45°C 14 to 113°F when expansion unit(s) is connected)
35 to 85% RH (No condensation)
4 to 20 mA, maximum load resistance: 350 Ω
Analog output range can be changed as desired.
10 to 55 Hz, 1.5 mm 0.06" double amplitude, 2 hours in each of X, Y, and Z directions
Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC
GT2-71N/71P/72N/72P: Approx. 140 g (including power cable), GT2-71CN/71CP/72CN/72CP/71MCN/71MCP: Approx. 70 g
GT2-71N/71P/71CN/71CP/71MCN/71MCP: Instruction manual, Cover seal, GT2-72N/72P/72CN/72CP: None
❙
Panel mount type amplifi er unit
Model
NPN output
PNP output
GT2-75N
GT2-75P
Mounting method
Main unit / Expansion unit *
1
Main unit
Panel mount
GT2-76N
GT2-76P
Expansion unit
GT2-100N
GT2-100P
Panel mount/Screw mounting using optional mounting bracket
2 channels provided as standard. Addition of expansion boards allows expansion to 11 channels max.
GT2-E3N
GT2-E3P
Installed into GT2-100N/100P
(up to 3 boards)
Expansion unit (1 to 3 channels)
Appearance
Power supply voltage * 1
Power consumption *
2
Normal
Power saving (Eco)
Display power
Measured value display
Other displays
Display range
Display resolution
Sampling rate
Timing input
Preset input
Control input
Reset input
Bank input
10 to 30 VDC, including 10% ripple (P-P)
2200 mW max. (30 V, 73.3 mA max.)
1700 mW max. (30 V, 56.7 mA max.)
6 + 1/2-digit 7-segment LED (red)
2-color, 13-level bar LED display (red, green), indicators (red, green)
-199.999.9 to 199.999.9
0.1 µm 0.004 Mil
20 to 30 VDC, including 10% ripple (P-P)
4500 mW max. (30 V, 150 mA max.)
3600 mW max. (30 V, 120 mA max.)
1000 times/sec.
Input time: 2 ms min.
Input time: 20 ms min.
Supplied from GT2-100N/100P
4200 mW max. (30 V, 140 mA max.)
4000 mW max. (30 V, 133.3 mA max.)
–
Control output
Response time
Ambient temperature
Environmental resistance
Relative humidity
Materials
Vibration
Power supply / I/O cable
Weight
Accessories
HH / High / Go /
Low / LL
NPN/PNP open collector, Applicable current: 50 mA,
Maximum applicable voltage (NPN: 40 V, PNP: 30 V)
Residual voltage at ON: 1 V max. * N.O./N.C switchable
(Applicable current decreases to 20 mA or lower when 2 or more sensor heads are connected to the GT2-100 Series.) hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s
-10 to +50°C 14 to 122°F
35 to 85% RH (No condensation)
10 to 55 Hz, 1.5 mm 0.06" double amplitude, 2 hours in each of X, Y, and Z directions (GT2-100N/P: 0.15 mm 0.01" double amplitude)
– Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC (GT2-75N/75P/76N/76P only)
12-core connector connection (Connecting cable included)
Power supply: Terminal block,
I/O: 20-pin connector (MIL standard)
I/O: 30-pin connector (MIL standard)
GT2-75N/75P/76N/76P: Approx. 140 g (including panel mounting bracket, protective front cover and power cable)
GT2-100N/100P: Approx. 380 g, GT2-E3N/E3P: Approx. 80 g
GT2-75N/75P: Panel mounting bracket, protective front cover, power cable, instruction manual, cover seal
GT2-76N/76P: Panel mounting bracket, protective front cover, power cable, expansion cable
GT2-100N/100P: Instruction manual, panel mounting bracket, GT2-E3N/E3P: None
*1 Precautions when the GT2-70 Series is used with an expansion unit (excluding GT2-71D)
Up to 15 amplifi er units can be connected; main unit: 1 unit, expansion unit: 14 units. To use the DIN-rail mount type, be sure to mount the amplifi er unit to a DIN-rail (using the metal bracket). When mounting additional units, be sure to use the end units (OP-26751). When mounting additional units, depending on the number of units to be added, confi rm the following specifi cation limitations.
<Up to 8 units (including main unit)>
• The power supply voltage is 20 to 30 VDC.
<Up to 9 to 15 units (including main unit)>
• The power supply voltage is 20 to 30 VDC.
• The maximum applicable current for each output is 20 mA.
• The maximum applicable current for each output is 10 mA (including DL-RB1A output current).
• The residual voltage at ON Is 1.5 V or less.
*2 For GT2-100 Series, when the maximum number of sensor heads are connected and all units are set to power saving mode
21
22
Specifi cations
❙
DIN-rail mount type pulse output amplifi er unit
Model GT2-71D
Appearance
Mounting method
Power supply voltage
Current consumption
Indicator
Pulse resolution
Minimum phase difference
Control input Origin return
Output signal
Output signal level
Environmental resistance
Ambient temperature
Relative humidity
Vibration
Material
Weight
Accessories
DIN-rail mount
10 to 30 VDC, including 10% ripple (P-P)
1600 mW (30 V, 53.3 mA max.)
Power supply (green)/Alarm (red) indicator, pulse output indicator (green), input indicator (green)
Selectable from 0.1 µm 0.004 Mil , 0.5 µm 0.02 Mil , 1 µm 0.04 Mil , and 10 µm 0.39 Mil (Factory setting: 0.5 µm 0.02 Mil )
Selectable from 0.5 µs, 2.5 µs, 5 µs, and 25 µs (Factory setting: 2.5 µs)
Input time: 20 ms min.
90° phase difference, differential square wave (EIA-422 compliant)
+5V, øA, øA-, øB, øB-, øZ, øZ-: Line driver output
-10 to +50°C 14 to 122°F
35 to 85% RH (No condensation)
10 to 55 Hz, 1.5 mm 0.06" double amplitude,
2 hours in each of X, Y, and Z directions
Main body case: Polycarbonate, Cable: PVC
Approx. 110 g (including power supply cable)
Instruction manual, SW protection sticker
❙
Communication unit (Common specifi cations)
Model DL-RB1A DL-RS1A
❙
Communication unit (DL-RS1A Communication Specifi cations)
Model DL-RS1A
Appearance Appearance
Power supply voltage
Power consumption
Number of connectable sensor amplifi ers
Indicator
Ambient temperature
Relative humidity
Environmental resistance
Vibration
Material
Weight
Accessories
20 to 30 VDC, including ripple,
Ripple (P-P): 10% max.
(Supplied via connected sensor amplifi er)
27 mA max. 25 mA max.
Up to 15 units (including main unit)
Alarm indicator lamp
(red),
Power indicator lamp
(green)
Communication indicator lamp
(green x 2),
Alarm indicator lamp
(red),
Power indicator lamp
(green)
-10 to +55°C 14 to 131°F
35 to 85% RH (No condensation)
10 to 55 Hz,
1.5 mm 0.06" double amplitude,
2 hours in each of X, Y, and Z directions
Main body case: Polycarbonate
Approx. 46 g Approx. 53 g
Instruction manual, End units (x 2),
Switch protection seal,
Expansion connector cover
Communication method
Synchronization method
Transmission code
Baud rate
Date bit length
Parity check
Stop bit length
Data delimiter
Full duplex
Start-stop
ASCII
2400/4800/9600/19200/38400 bps selectable
(Factory-setting: 9600 bps)
8-bit/7-bit selectable (Factory-setting: 8 bits)
None/Even/Odd selectable
(Factory- setting: None)
1 bit
Data reception: automatically recognizes CR or CR+LF
Data transmission: Fixed to CR+LF
❙
Pin assignment for the DL-RB1A (BCD)
11
12
13
14
15
16
17
7
8
9
10
Pin No.
1
2
3
4
5
6
Signal name
IDSEL 1
IDSEL 2
IDSEL 3
IDSEL 4
DRQ
BCD DIGIT 1 (1)
BCD DIGIT 1 (2)
BCD DIGIT 1 (4)
BCD DIGIT 1 (8)
BCD DIGIT 2 (1)
BCD DIGIT 2 (2)
BCD DIGIT 2 (4)
BCD DIGIT 2 (8)
BCD DIGIT 3 (1)
BCD DIGIT 3 (2)
BCD DIGIT 3 (4)
BCD DIGIT 3 (8)
Description
ID No. selection input 1
ID No. selection input 2
ID No. selection input 3
ID No. selection input 4
Data request input
BCD 1st digit 1×10 0
BCD 1st digit 2×10 0
BCD 1st digit 4×10
0
BCD 1st digit 8×10
0
BCD 2nd digit 1×10 1
BCD 2nd digit 2×10 1
BCD 2nd digit 4×10 1
BCD 2nd digit 8×10
1
BCD 3rd digit 1×10 2
BCD 3rd digit 2×10 2
BCD 3rd digit 4×10 2
BCD 3rd digit 8×10 2
28
29
30
31
32
33
34
24
25
26
27
Pin No.
18
19
20
21
22
23
Signal name
BCD DIGIT 4 (1)
BCD DIGIT 4 (2)
BCD DIGIT 4 (4)
BCD DIGIT 4 (8)
BCD DIGIT 5 (1)
BCD DIGIT 5 (2)
BCD DIGIT 5 (4)
BCD DIGIT 5 (8)
BCD DIGIT 6 (1)
BCD DIGIT 6 (2)
BCD DIGIT 6 (4)
BCD DIGIT 6 (8)
BCD SIGN
BCD STB
ALARM
COM
COM
Description
BCD 4th digit 1×10
3
BCD 4th digit 2×10 3
BCD 4th digit 4×10 3
BCD 4th digit 8×10
3
BCD 5th digit 1×10
4
BCD 5th digit 2×10 4
BCD 5th digit 4×10 4
BCD 5th digit 8×10
4
BCD 6th digit 1×10
5
BCD 6th digit 2×10 5
BCD 6th digit 4×10 5
BCD 6th digit 8×10 5
BCD data polarity sign
Strobe output
Alarm output
Common
Common
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
1 2
3 4
5 6
7 8
9 10
11 12
13 14
Input/Output Circuits
I/O circuit (GT2-71N/72N/71CN/72CN/71MCN/75N/76N)
Input circuit
Brown * 1
10 to 30 VDC * 3
Orange (HH output) * 2
Load
Black (HI output)
Load
Gray (GO output)
Load
5 to 40 VDC
5 to 40 VDC
5 to 40 VDC
White (LO output)
Load
5 to 40 VDC
Green (LL output) * 2
Load 5 to 40 VDC
Blue *
1
0 V
Pink, purple, pink/purple, yellow, red * 4
External input
External input circuit
5VDC
(Short-circuit current: 1 mA max.)
Blue *
1
Pink: Preset input
Purple: Bank A input
Pink/purple: Timing input
Yellow: Bank B input
Red: Reset input
I/O circuit (GT2-71P/72P/71CP/72CP/71MCP/75P/76P)
Input circuit
Brown *
1
Orange (HH output) * 2
Black (HI output)
Gray (GO output)
White (LO output)
Green (LL output) * 2
Load
Blue * 1
Load
Load
Load
Load
Pink, purple, pink/purple, yellow, red * 4
10 to 30 VDC * 3
0 V
External input
External input circuit
(Short-circuit current: 2 mA max.)
10 to 30 VDC
Brown * 1
Pink: Preset input
Purple: Bank A input
Pink/purple: Timing input
Yellow: Bank B input
Red: Reset input
*1 Brown and blue are applicable only to main units (GT2-71N/71P/71CN/71CP/71MCN/71MCP/75N/75P). Not to expansion units (GT2-72N/72P/72CN/72CP/76N/76P).
The connector type expansion unit (GT2-72CN/72CP) is not connected to the internal circuit.
*2 The orange and green cables are used as analog output cables for the analog type amplifi er unit (GT2-71MCN/71MCP).
For details, refer to the analog output circuit diagram.
*3 20 to 30 VDC when expansion unit is connected or for the analog type amplifi er unit (GT2-71MCN/71MCP).
*4 For details on external input, refer to the external input circuit diagram.
Analog output circuit
GT2-71MCN/71MCP
Orange
Green *
Analog output
(4 to 20 mA)
0 V (for analog)
* The green and blue cables are common internally.
Pulse output amplifi er unit (GT2-71D)
I/O circuit
5 VDC
33 Ω
33 Ω
Input circuit
Brown
10 to 30 VDC
Black, white, orange
Purple, gray,
Black: Phase A, White: Phase
B, Orange: Phase Z green
Purple: Reversed phase A
Gray: Reversed phase B
Green: Reversed phase Z
Blue
0 V
Pink *
Input
External input circuit
5 VDC
(Short-circuit current: 1 mA max.)
Pink
Blue
* For details of the external input, refer to the diagram of the external input circuit.
Recommended input device
AM26LS32 line receiver or equivalent device
390 Ω
Output circuit of the large display amplifi er unit
GT2-100N/GT2-E3N
(Pin Nos. 1 to 5, 11 to 15, 21 to 25)
+ *
20 to 30 VDC
1 to 5, 11 to 15, 21 to 25
Load 5 to 40 VDC
- *
0 V
* The +/- terminals are provided in the GT2-100N only.
They are not provided in the GT2-E3N.
Output circuit of the large display amplifi er unit
GT2-100P/GT2-E3P
(Pin Nos. 1 to 5, 11 to 15, 21 to 25)
+ *
20 to 30 VDC
1 to 5, 11 to 15, 21 to 25
Load
- *
0 V
* The +/- terminals are provided in the GT2-100P only.
They are not provided in the GT2-E3P.
Input circuit of the large display amplifi er unit
GT2-100N/GT2-E3N
(Pin Nos. 6 to 10, 16 to 20, 26 to 30)
5 VDC
6 to 10, 16 to 20, 26 to 30
- *
(Short-circuit current: 1 mA max.)
* The - terminal is provided in the GT2-100N only.
It is not provided in the GT2-E3N.
Input circuit of the large display amplifi er unit
GT2-100P/GT2-E3P
(Pin Nos. 6 to 10, 16 to 20, 26 to 30)
20 to 30 VDC
+ *
(Short-circuit current: 2 mA max.)
6 to 10, 16 to 20, 26 to 30
* The + terminal is provided in the GT2-100P only.
It is not provided in the GT2-E3P.
For details of the I/O connector pin assignment and the expansion board, refer to the instruction manual. The information is also available at the KEYENCE home page. www.keyence.com
23
24
Dimensions
Sensor head (Standard)
GT2-H12K/GT2-H12
ø8
ø0.31"
1.10"
28
0.61"
15.5
M8 cable connector
0.63"
16
(0.49")
(12.5)
5.9
(6.4) (0.25")
0.23"
(10.1)
(0.40")
Cable connection
(Straight)
ø0.37" ø9.5
0.42"
10.7
0.05"
1.15
(58)
(2.28")
66.7
73.1
2.63" 2.88"
0.24"
6
ø8 ø0.31" h5
( )
-0.006
( )
ø11.6
ø0.46"
8.7
0.34"
15.1
0.59"
41.5
to
29.0
45.3
to
32.8
1.63" to
1.78" to
1.14"
1.29"
(22)
(0.87")
3.8
0.15"
6.4
0.25"
ø4 ø0.16"
(9.6)
(0.38")
95.3
3.75"
Unit: mm inch
Cable connection
(L-shaped)
1.15
0.05"
ø9.5
ø0.37"
9
0.35"
0.80"
20.2
3.05
0.12"
92.3
3.63"
Sensor head (Low stress)
GT2-H12KL/GT2-H12L
ø8
ø0.31"
1.10"
28
0.61"
15.5
M8 cable connector
0.63"
16
(0.49")
(12.5)
5.9
(6.4) (0.25")
0.23"
(10.1)
(0.40")
Cable connection
(Straight)
ø0.37" ø9.5
0.42"
10.7
0.05"
1.15
(58)
(2.28")
66.7 73.1
2.63" 2.88"
95.3
3.75"
0.24"
6
ø8 ø0.31" h5
( )
-0.006
( )
ø11.6
ø0.46"
8.7
0.34"
15.1
0.59"
41.5
to
29.0
45.3
to
1.63" to
32.8
1.78"
1.14" to
1.29"
(22)
(0.87")
3.8
0.15"
6.4
0.25"
ø4 ø0.16"
(9.6)
(0.38")
Sensor head (Standard)
GT2-H32
0.70"
17.8
1.48"
37.6
0.99"
25.1
(12.5) (0.49")
(19.8) (0.78")
ø8
ø0.31"
(6.4) (0.25")
M8 cable connector
8.15
0.32"
2-ø4.3
ø0.17"
ø12 ø0.47"
116.4
4.58"
0.91"
23
0.34" 8.7
5.9 0.23"
h6
ø15
ø0.59"
30
1.18"
0.48"
12.2
(53.3)
(2.10")
0.38"
9.7
(0.56")
(88.5)
(3.48")
90.9
3.58"
97.3
3.83"
(14.3)
27.9 1.10"
0.15"
3.8
17 0.67"
2.4
(17.8)
(0.70")
0.09"
43.8
to
77.8
1.72" to
3.06"
47.6
to
81.6
1.87" to
3.21"
(25.4) (1.00")
ø0.20"
ø5
12.2
0.48"
0.78"
19.7
(11.55)
(0.45")
0.3
20
0.01"
0.79"
(7.8) (0.31")
Cable connection
(Straight)
3.4
0.13"
Cable connection
(L-shaped)
1.15
0.05"
ø9.5
ø0.37"
9
0.35"
0.80"
20.2
3.05
0.12"
92.3
3.63"
ø9.5
ø0.37"
119.5
4.70"
20.35
0.80"
Sensor head
(Low stress)
GT2-H32L
0.70"
17.8
1.48"
37.6
0.99"
25.1
(12.5) (0.49")
(19.8) (0.78")
ø8
ø0.31"
(6.4) (0.25")
M8 cable connector
8.15
0.32"
2-ø4.3
ø0.17"
ø12 ø0.47"
116.4
4.58"
0.91"
23
0.34" 8.7
5.9 0.23"
h6
ø15
ø0.59"
30
1.18"
0.48"
12.2
(53.3)
(2.10")
0.38"
9.7
(0.56")
(88.5)
(3.48")
90.9
3.58"
97.3
3.83"
(14.3)
27.9 1.10"
0.15" (0.70")
3.8
17 0.67"
2.4
0.09"
(17.8)
43.8
to
77.8
1.72" to
3.06"
47.6
to
81.6
1.87" to
3.21"
(25.4) (1.00")
ø0.20"
ø5
12.2
0.48"
0.78"
19.7
(11.55)
(0.45")
0.3
20
0.01"
0.79"
(7.8) (0.31")
Cable connection
(Straight)
3.4
0.13"
ø9.5
ø0.37"
119.5
4.70"
20.35
0.80"
Unit: mm inch
Sensor head (Standard)
GT2-H50
0.70"
17.8
1.48"
37.6
0.99"
25.1
M8 cable connector
(12.5) (0.49")
(19.8) (0.78")
ø8 ø0.31"
(0.25")
(6.4)
8.15
0.32"
0.78"
19.7
(11.55)
(0.45")
Sensor head (Standard)
GT2-A12/GT2-A12K
152.4
6.00"
0.91"
23
0.34" 8.7
0.23"
5.9
2-ø4.3
ø0.17"
ø15
ø0.59"
30
1.18"
12.2
0.48"
ø12 ø0.47" h6
( )
-0.011
( )
(53.3)
(2.10")
0.38"
9.7
(106.5)
(4.19")
(14.3)
(0.56")
45.9
1.80"
108.9
4.29"
115.3
4.54"
0.15"
3.8
17 0.67"
2.4
0.09"
(17.8)
(0.70")
48.6
to
100.6
52.4
to
104.4
1.91" to
3.96"
2.06" to
4.11"
(25.4)
(1.00")
ø5
ø0.20"
12.2
0.48"
0.42" 10.75
0.61" 15.5
0.23" 5.95
28
1.10"
ø9.5 ø0.37"
(12.5) (0.49")
M8 connector
(0.3) (0.01")
20 0.79"
(7.8)
(0.30")
There are no dust boots on the low stress type
GT2-A12L/A12KL
Sensor head (Standard)
GT2-A32
Sensor head (Standard)
GT2-A50
0.04" 1.05
0.06" 1.55
0.12"
ø0.46"
3.05
ø11.6
(58)
(2.28")
66.7
2.63"
95.3
3.75"
0.34" 8.7
0.59" 15.1
1.14"
to
29
to
1.63" 41.5
32.8
to
45.3
1.29"
to
1.78"
(22) (0.87")
3.8 0.15"
0.24" 6
ø8 ø0.31" h5
0.49" 25.1
0.70" 17.8
0.80" 20.35
37.6
1.48"
(12.5) (0.49")
(19.8) (0.78")
ø9.5 ø0.37"
M8 connector
0.91" 23
(0.56") (14.3)
0.34" 8.7
0.23" 5.9
ø0.17"
2 - ø4.3
1.18"
(0.70")
ø15
ø0.59"
30
(17.8)
0.48" 12.2
ø12 ø0.47" h6
0.99" 25.1
0.70" 17.8
0.80" 20.35
(53.3)
(2.10")
88.5
119.5
4.70"
3.48"
90.9
9.7 0.38"
3.58"
27.9
1.10"
0.09"
2.4
17
0.67"
44.3
to
77.8
1.74"
to
3.06"
48.1
to
81.6
1.89"
to
3.21"
3.8 0.15"
(25.4) (1.00")
37.6
1.48"
(12.5) (0.49")
(19.8) (0.78")
ø9.5 ø0.37"
Cable connection
(Straight)
3.4
0.13"
ø0.37" ø9.5
137.5
5.41"
20.35 0.80"
1.00" 25.5
(0.40") (10.1)
0.23" 5.9
0.05" 1.15
32.5
1.28"
16
0.63"
One-touch air supply joint
(for 4 mm 0.16" outside diameter air tube.)
Air exhaust joint
(for 2.5 mm 0.10" inside diameter air tube.)
ø14 ø0.55"
0.88"
0.99"
22.4
25.15
(0.22")
(5.5)
97.35
3.83"
0.22" 12.5
39.8
1.57"
84.85
3.34"
17.7
0.70"
13.1 0.52"
15 0.59"
18 0.71"
8.75
0.34"
ø0.16" ø4
0.25" 6.4
0.32" 8.15
34.5
1.36"
1.46"
37
30
1.18"
19.7
0.78"
(9.6) (0.38")
One-touch air supply joint
(for 4 mm
(11.55)
(0.45")
0.16" outside diameter air tube.)
Air exhaust joint
(for 2.5 mm 0.10" inside diameter air tube.)
ø14 ø0.55"
1.17" 29.75
0.13" 3.4
1.06" 27
15 0.59"
0.49" 12.5
155.2
6.11"
(5.5)
(0.22")
142.7
5.62"
75.65
2.98"
18 0.71"
28.1 1.11"
32.7 1.29"
15 0.59"
18 0.71"
0.01" 0.3
5.6
0.22"
ø0.20" ø5
0.48" 12.2
0.32" 8.15
39
1.54"
1.46"
37
30
1.18"
19.7
0.78"
1.17" 29.75
1.06" 27
(7.8) (0.31")
One-touch air supply joint
(for 4 mm
(11.55)
0.16"
(0.45")
outside diameter air tube.)
Air exhaust joint
(for 2.5 mm 0.10" inside diameter air tube.)
ø14 ø0.55"
15 0.59"
M8 connector
0.91" 23
(0.56") (14.3)
0.34" 8.7
0.23" 5.9
ø0.17"
2 - ø4.3
ø15
ø0.59"
1.18" 30
(0.70") (17.8)
0.48" 12.2
ø12 ø0.47" h6
(53.3)
(2.10")
106.5
4.19"
9.7 0.38"
137.5
5.41"
108.9
4.29"
45.89
1.81" 0.09"
2.4
49.1
to
17
0.67"
100.6
1.93"
to 52.9
3.96" to
104.4
2.08"
to
4.11"
3.8 0.15"
(25.4) (1.00")
0.13" 3.4
0.01" 0.3
178.7
7.04"
0.49" 12.5
(5.5)
(0.22")
191.2
7.53"
93.65
3.69"
5.6
0.22"
ø0.20" ø5
0.48" 12.2
39
1.54"
(7.8) (0.31")
18 0.71"
28.1 1.11"
32.7 1.29"
15 0.59"
18 0.71"
25
26
Dimensions
Unit: mm inch
Sensor head cable (Straight)
GT2-CH2M/CH5M/CH10M/CH20M
(Optional)
A
ø9.5
ø0.37"
27.2
1.07"
7.2
0.28"
C
L
ø11 ø0.43"
2
ø0.19"
ø4.8, 4 x 0.22 mm
2
1
4
A
3
4
3
2
1
B
21.4
0.84"
20.6 0.81"
10.4 0.41"
C
B
C-C
9.4 0.37"
Sensor head cable (L-shaped)
GT2-CHL2M/CHL5M/CHL10M/CHL20M
(Optional)
0.95" 24.2
23
0.91"
L
ø0.43" ø11
C
20.6 0.81"
A
ø7
ø0.28"
ø9
ø9
ø0.35"
ø0.35"
2
1
4
A
3
ø0.19"
ø4.8,
4 x 0.22 mm
2
4
3
2
1
B
21.4
0.84"
10.4 0.41"
C
B
C-C
9.4 0.37"
Sensor head mounting bracket A (Optional)
OP-76874
0.47" 12
ø10 ø0.39" g6
( )
( )
C1.5
C0.06"
Material: TYPE304
Stainless
steel
12 0.47"
R6.5
R0.26"
Mounting hole
ø8 ø0.31"
G6
( ) ( )
6
0.24"
+0.0006"
+0.0002"
16.3
0.64"
ø10 ø0.39"
C0.5 to C1.0
G8
C0.02" to C0.04"
( )
3.5
0.14"
7.8
0.31"
5.5 to 11.3
0.22" to 0.44"
Sensor head mounting bracket C (Optional)
OP-84396
0.47" 12
ø10 ø0.39" g6
( )
( )
C1.5
C0.06"
Material: TYPE304
Stainless
steel
12 0.47"
R6.5
R0.26"
ø8 ø0.31"
G6
( ) ( )
5
0.20"
6
0.24"
16.3
0.64"
7.8
0.31"
Mounting hole
ø10 ø0.39"
C0.5 to C1.0
C0.02" to C0.04"
( )
( )
5.5 to 11.3
0.22" to 0.44"
Sensor head mounting bracket B (Optional)
OP-76875
16.3
0.64"
11
0.43"
10.5
0.41"
6.5
0.26"
(0.01")
(0.2)
32 1.26"
R8
R0.31"
4-C2 C0.08"
12.1
0.48"
0.25" 6.3
ø4.2
ø0.17"
R3.8
R0.15"
15
0.59"
3.5
0.14"
Material: TYPE304
ø8 ø0.31" G6
( )
2
3
A
1
4
3
4
B
1
2
Sheath color
Brown
White
Blue
Black
Model
GT2-CH2M
GT2-CH5M
GT2-CH10M
GT2-CH20M
L
2000 78.74"
5000 196.85"
10000 393.70"
20000 787.40"
2
3
A
1
4
B
1
3
4
2
Sheath color
Brown
White
Blue
Black
Model
GT2-CHL2M
GT2-CHL5M
GT2-CHL10M
GT2-CHL20M
L
2000 78.74"
5000 196.85"
10000 393.70"
20000 787.40"
Dust boot
25.3
1.00"
ø7.6 ø0.30"
For GT2-H12K/
H12/A12K/A12
(Optional)
OP-84332
* The dust boot is factory-attached
to the sensor head
(except for the low stress type).
Material: TYPE304
Stainless steel, NBR
58.2
2.29"
ø11.6 ø0.46"
For GT2-H32/A32
(Optional)
OP-84459
81
3.19"
ø11.6 ø0.46"
For GT2-H50/A50
(Optional)
OP-84460
Sensor head mounting bracket D (Optional)
OP-84327
0.63"
16
0.63"
16
R0.33"
R8.5
ø0.47"
ø12
G6
ø14
ø0.55" g6
( )
( )
C1.5
C0.06"
6 0.24"
7.8 0.31"
16.3
0.64"
5 0.20"
17 0.67"
Material: TYPE303
Stainless
steel
17
0.67"
17
0.67"
Mounting hole
ø14 ø0.55"
( )
( )
C0.02" to C0.04"
C0.5 to C1.0
5.5 to 11.3
0.22" to 0.44"
Unit: mm inch
Contact
Standard
OP-77678
5 0.20"
0.02"
M2.5 × 0.45
3.8
0.15"
SR1.5 0.06"
ø5 ø0.20"
Standard equipment of the generalpurpose sensor head
GT2-H12 (L)/
H32 (L)/H50/
A12 (L)/A32/A50
Material: TYPE304
TYPE440C
Fluorocarbon resin
(Optional)
OP-80228
0.20"
5
9
0.35"
Super-tough
OP-77682
5 0.20"
0.02"
M2.5 × 0.45
ø5 ø0.20"
Flat plate (Optional)
OP-77679
5 0.20"
0.02"
M2.5 × 0.45
Roller (Optional)
OP-77680
ø7.5
ø0.30"
0.14"
3.5
ø9 ø0.35"
0.02"
M2.5 × 0.45
0.37" 9.5
0.02"
M2.5 × 0.45
3.8
0.15"
SR1.5 0.06"
ø5 ø0.20"
Standard equipment of the high-accuracy type sensor head
GT2-H12K (L)/
A12K (L)
Material: TYPE304
Super-tough tungsten alloy
Ceramic (Optional)
OP-81970
0.20"
5
0.02"
M2.5 × 0.45
4.5
0.18"
ø7
ø0.28"
ø6 ø0.24"
0.30" 7.5
Material: TYPE304
Super-tough
Needle (Optional)
OP-77681
0.20"
5
6.2
0.24"
0.02"
M2.5 × 0.45
Material: TYPE304
4.5
0.18"
TYPE440C steel 4.4
4
0.17" 0.16"
9
0.35"
Offset (Optional)
OP-77683
ø6
ø0.24"
8
0.31"
0.20" 5
SR1.5 0.06"
ø5 ø0.20"
3.8
0.15"
SR1.5 0.06"
21
0.83"
20
0.79"
ø9
ø0.35"
ø7.5
ø0.30"
0.02"
M2.5 × 0.45
3.5
0.14"
Material: Fluorocarbon resin (PTFE) Material: TYPE304 Stainless steel,
Ceramic
SR0.8 0.03"
10
0.39"
ø1.6
ø0.06"
C0.2 C0.008"
ø1.2
ø0.05"
ø4 ø0.16"
Material: TYPE304
Super-tough tungsten alloy
Lift lever (Optional)
OP-84397
3.6
0.14"
0.09"
2.3
21.4
0.84"
19.2
0.76"
8.3
0.33"
15.3
0.60"
5.2
0.20"
4.7
0.19"
Material: TYPE304
0.8
0.03"
Spacer (Optional)
OP-77684
5.5
0.22"
0.08"
12.2 2
0.48"
M2.5 × 0.45 0.02"
3.6
0.14"
M2.5 × 0.45 0.02"
Effective screw depth:
6.5 mm
ø4 ø0.16"
Material: TYPE304
Stainless steel
0.26"
Material: TYPE304
Super-tough tungsten alloy
Amplifier unit
DIN-rail mount type
GT2-71N/71P/71MCN/71MCP/71CN/71CP
*
24
0.94" 14.6
0.57"
8.9
0.35"
GT2-72N/72P/72CN/72CP
24
0.94"
*
14.6
0.57"
8.9
0.35"
0.12"
3
135° max.
0.12"
3
41.8
1.65"
36.9
1.45"
12.4
0.49"
17.4
0.69"
(Maximum when cover is opened)
82.9 3.26"
41.8
1.65"
36.9
1.45"
12.4
0.49"
17.4
0.69"
15 0.59" min.
20 21.1
0.79" 0.83"
35.4
1.39"
75.8
2.98" 15 0.59" min.
(Maximum when cover is opened) 132.6 5.22"
15 0.59" min.
20 21.1
0.79" 0.83"
35.4
75.8
1.39"
2.98" 15 0.59" min.
* Cable specifications
GT2-71N/71P: ø4.7 ø0.19" , 12-core x Brown/Blue: 0.20 mm 2 , Black/White/Gray/Orange/Green/Pink/Purple/Yellow/Red/Pink purple: 0.15 mm 2 , Cable length: 2 m 6.6'
GT2-72N/72P: ø4.7 ø0.19" , 10-core x Black/White/Gray/Orange/Green/Pink/Purple/Yellow/Red/Pink purple: 0.15 mm
2
, Cable length: 2 m 6.6'
GT2-71MCN/71MCP/71CN/71CP/72CN/72CP
Connector
(connector type/analog output type amplifier unit)
46 1.81"
ø15 ø0.59" ø0.59" ø15
GT2-CA2M/CA10M
Connection cable
44 1.73"
Cable length: 0.3 m, ø4.7
1.18', ø0.19"
*
* Cable specifications
Outer diameter: ø4.7 mm ø0.19" , Cable length: 2 m 6.6' (GT2-CA2M), 10 m 32.8' (GT2-CA10M),
12-core x Brown/Blue: 0.20 mm 2 , Black/White/Gray/Orange/Green/Pink/Purple/Yellow/Red/
Pink purple: 0.15 mm 2
27
28
Dimensions
Unit: mm inch
Amplifier unit
Pulse output
GT2-71D
0.94" 24
8.9
0.35"
*
14.6 0.57"
0.12"
3
135° max.
41.8
1.65"
36.9
1.45"
0.49"
12.4
15 0.59" min.
20
0.79"
17.4 0.69"
21.1
0.83"
35.4
1.39"
75.8 2.98"
(Maximum when cover is opened) 132.6 5.22"
15 0.59" min.
* Cable specifications
Outer diameter: ø4.7 mm ø0.19" , Cable length: 2 m 6.6' ,
9-core x Brown/Blue/Purple/Pink/Orange/Green/Gray/White/Black: 0.15 mm 2
(Maximum when cover is opened)
82.9 3.26"
Mounting bracket for
DIN-rail mount type amplifier (Optional)
OP-76877
5
0.20"
15
0.59"
2-(4.4 × 3.4)
(0.17" × 0.13")
2-ø3.4
ø0.13"
24
0.94"
22
0.87"
15
0.59"
28.6
1.13"
35 1.38"
Material: SPCC steel
End unit (Optional) (2 pcs.)
OP-26751
0.24"
6
DIN-rail mount
(22.6)
(0.89")
20.8
0.82"
9.2
0.36"
35.4
1.39"
53.8
2.12"
Material: Polycarbonate, Stainless steel
When several units are connected
L
6
0.24"
53.8
2.12"
10.1
0.40"
6
0.24"
53.8
2.12"
10.1
0.40"
Number of units
1
5
6
7
8
9
2
3
4
10
11
12
13
14
15
L
24 0.94"
48 1.89"
72 2.83"
96 3.78"
120 4.72"
144 5.67"
168 6.61"
192 7.56"
216 8.50"
240 9.45"
264 10.39"
288 11.34"
312 12.28"
336 13.23"
360 14.17"
Amplifier unit
Panel mount type
GT2-75N/75P/76N/76P
44.7
1.76"
13.9
0.55"
13.4
0.53"
Panel mounting bracket
(Accessory)
OP-84394
0.06" 1.5
66 2.60"
2.05"
0.28"
7
52
2.3
0.09"
23.9
0.94"
* Cable specifications (common to all amplifier units)
GT2-75N/75P: ø4.7 ø0.19" , 12-core x Brown/Blue: 0.20 mm 2 , Black/White/Gray/
Orange/Green/Pink/Purple/Yellow/Red/Pink purple: 0.15 mm 2 ,
Cable length: 2 m 6.6'
GT2-76N/76P: ø4.7 ø0.19" , 10-core x Black/White/Gray/Orange/Green/Pink/
Purple/Yellow/Red/Pink purple: 0.15 mm 2 , Cable length: 2 m 6.6'
0.78"
19.8
*
12.2
20.9
0.48"
0.82"
8.5
0.33"
4.1
0.16"
38.8
1.53"
X
49 1.93"
24
0.94"
Protective front cover
23.8
0.94"
21
0.84"
+0.4
-0
+0.02"
-0
69 2.72"
11.7
0.46"
Material: (Mounting bracket) Polyacetal,
(Protective front cover) Polycarbonate
Panel cutout
45 1.77"
45 1.77"
X = 24 x (A-1) + 21
0.94" 0.84"
When A amplifier units are closely mounted
69.5 2.74" min.
Panel mounting bracket
(73) (2.87")
11.9
0.47"
Panel thickness
1 to 6
0.04" to 0.24"
Amplifier unit
Large display
GT2-100N/100P
When the supplied mounting bracket is attached
159.5 6.28"
0.04" to 0.24"
Panel thickness: 1 to 6
79.8
3.14"
49.3
1.94"
75.8
2.98"
82.7
3.26"
1.18"
29.9
60 2.36"
0.43" 11
0.48" 12.1
82 3.23"
85.2 3.35"
1.57" 40
1.10" 28
Screw hole for mounting OP84331
Nominal diameter: 3 0.12" , Tapping depth: 5 0.20" max.
138.8 5.46"
161.8 6.37" (Outer dimension of the supplied mounting bracket)
97.2
3.83"
(119.6)
(4.71")
(139.4)
(5.49")
Panel cutout
139.5 5.49"
+1 +0.04"
-0 -0
0.05" 1.2
76 2.99"
+1 +0.04"
-0 -0
When the optional mounting bracket (OP-84331) is used
Unit: mm inch
GT2-E3N/E3P Expansion board
133 5.24"
1.6
0.06"
15.1
0.59"
1.34" 34
1.57" 40
Nominal diameter: 3 0.12" , 4-ø5 ø0.20" fastened with four tapping screws (supplied)
5.6 0.22"
150 5.91"
5.6
0.22"
Communication unit
BCD output type
DL-RB1A
DIN-rail mount
22.5
0.89"
84.4
3.32"
4.6
0.18"
ø0.14"
4-ø3.5
t=1.6
6.6
0.06"
0.26"
40
1.57"
1.10" 28
40.5
1.59"
60 2.36"
150 5.91"
160 6.30"
When the mounting bracket is attached (Optional)
OP-60412
34-pin MIL connector
53.4
2.10"
(57.8)
(2.28")
37.1
1.46"
21.1
0.83"
70
35.4
1.39"
2.76"
53.4
2.10"
60.9
2.40"
37.1
1.46"
31.4
1.24"
70
15
0.59"
2.76"
2-ø3.4
ø0.13"
2-(4.4 × 3.4)
(0.17" × 0.13")
22.5
0.89"
Material: SPCC
steel
15
0.59"
28.5
1.12"
35.5
1.40"
When the mounting bracket is attached (Optional)
OP-60412
Communication unit
RS-232C communication type
DL-RS1A
DIN-rail mount
22.5
0.89"
(48.2)
(1.90")
37.2
43.8
1.72"
1.46"
21.1
0.83"
70
35.4
1.39"
2.76"
51.3
2.02"
37.2
1.46"
43.8
1.72"
Material: SPCC
steel
31.4
1.24"
70
15
0.59"
2.76"
2-ø3.4
ø0.13"
2-(4.4 × 3.4)
(0.17" × 0.13")
22.5
0.89"
15
0.59"
28.5
1.12"
35.5
1.40"
CAD DATA Download Service www.keyence.com/cad
29
Product confi guration
Sensor head cable
→P.15/step 2
Display unit (amplifi er unit)
→P.16/step 4-5
Sensor head
→P.13/step 1
Mounting bracket
→P.15/step 3
Contact
→P.18/step 6
Communication unit
→P.18/step 7-8
30
Reference
❙
Calculation functions using expansion units
The GT2-70 Series* enables calculations such as the maximum and the minimum values of several detection points when several expansion units
(up to 14 units) are connected to a main unit. Outline of each calculation function is as follows:
No.
C1
C2
C3
C4
C5
C6
C7
Calculation function
Description
Number of connectable expansion units
Calculation mode
Dedicated
Calculation mode
Maximum value
Minimum value
Degree of fl atness
Average
Reference difference
Twist
Displays the minimum value of the values of the main unit and expansion unit(s).
Displays the difference between the maximum and the minimum value of the main unit and expansion unit(s).
Displays the resulting calculation of the average of the main unit and expansion unit(s).
Displays the difference obtained by subtracting the display value of the main unit from each of the expansion unit(s).
Displays the degree of twist calculated from the values of four sensor heads.
Warpage
Displays the maximum value of the values of the main unit and expansion unit(s).
Displays the degree of warpage calculated from the values three sensor heads.
1 to 14 units
Only 3 units
Only 2 units
2 to 14 units
Not selectable
Only 4 units
Only 3 units
C8 Thickness
Displays the thickness calculated by two sensor heads "sandwiching" a target between them.
* Except GT2-71D.
Only 1 unit Only 2 units
About “Calculation mode”
When “Calculation mode” is selected for “A1: Calculation mode”, the main unit outputs a calculation result, and output of the expansion unit is OFF.
(Except for a case where “C5: Difference from reference display” is selected)
NOTE - The calculation mode can be selected for the main unit to which one or more expansion units are connected.
About “Calculation dedicated mode”
When “Calculation dedicated mode” is selected for “A1: Calculation mode”, only the main unit outputs a calculation result, and the expansion unit outputs a judgment result based on each setting.
NOTE
- The calculation dedicated mode can be selected for the main unit to which two or more expansion units are connected.
- When the calculation dedicated mode is selected, “C5: Reference
Difference” cannot be selected for calculation method.
- When the calculation dedicated mode is selected, a sensor head cannot be connected to the main unit. Attach the supplied “sensor head connector seal” to the sensor head connector of the main unit.
❙
Bank function
With the Bank function, up to four patterns of HH, HIGH, LOW and LL set values, preset values can be registered in advance.
Since the registered settings (four patterns) can be easily changed, this function is useful for detection of several targets.
❙
About accuracy of the high-accuracy type
When the high-accuracy type measures a distance between two arbitrary points in the measuring range at an ambient temperature (20°C
(68°F)), the deviation from the actual value is 1 µm 0.04 Mil or less. For example, when a measurement result is 11 mm 0.43" , the actual value is in a range of 10.999 to 11.001 mm 0.4330" to 0.4331" . For several measurements, variations in the measured value are 1 µm 0.04 Mil or less.
❙
5-output function
(Except GT2-71MCN/71MCP)
This function enables differentiation of fi ve output statuses (HH,
HIGH, GO, LOW and LL). HH and LL outputs can also be used for jam detection.
General purpose digital contact sensor
GT Series
Features
[Easy setup]
Head installation is as easy as drilling a hole.
[Easy programming]
Auto-tuning function enables simple, sensor-like tuning.
[Smart operation]
Self-diagnostic function outputs an alarm when the sensor head cable becomes damaged
Setup
Amplifi er units
Appearance Model
GT-71A
GT-72A
GT-71AP
GT-72AP
GT-75A
GT-76A
GT-75AP
GT-76AP
Standard model
Shortest in its class
Total length 90 mm 3.54"
Smallest length among the 10-mm
0.39" stroke type sensor heads
DIN rail mount
Panel mount
Type
Main unit
Expansion unit
Main unit
Expansion unit
Main unit
Expansion unit
Main unit
Expansion unit
Output type
NPN
PNP
NPN
PNP
BCD output / RS-232C communication unit
Model Appearance Type
DL-RB1A
BCD
DL-RS1A
RS-232C
Low Stress model Air Push model
Using low force spring
10-mm 0.39" stroke sensor head
GT-H10
22-mm 0.87" stroke sensor head
GT-H22
10-mm 0.39" stroke, low stress sensor head
GT-H10L
22-mm 0.87" stroke, low stress sensor head
GT-H22L
10-mm 0.39" stroke air push type sensor head
GT-A10
22-mm 0.87" stroke air push type sensor head
GT-A22
31
http://www.measurecentral.com
NEW
Web Site Dedicated to
Measurement Solutions!
❙ TECHNICAL INFORMATION
❙ APPLICATION SEARCH FUNCTION
❙ FREE SOFTWARE DOWNLOAD
Laser Displacement (1D) LK-G Series
Measuring the thickness of a silicon wafer
Measuring the thickness of a glass plate
❙
Sampling rate of 50 kHz
❙
Linearity of ± 0.02% of F.S.
❙
Repeatability down to 0.01 µm 0.0004 Mil
Thickness measurement/loop control of a rubber sheet
Measuring the displacement of a rotating shaft
CALL
TOLL
FREE
T O C O N T A C T Y O U R L O C A L O F F I C E
1-888-KEYENCE
1 - 8 8 8 - 5 3 9 - 3 6 2 3
www.
keyence .com
SAFETY INFORMATION
Please read the instruction manual carefully in order to safely operate any KEYENCE product.
KEYENCE CORPORATION OF AMERICA
Corporate Office 669 River Drive, Suite 403, Elmwood Park, NJ 07407 PHONE: 201-930-0100 FAX: 201-930-0099 E-mail: [email protected]
Sales & Marketing Head Office 1100 North Arlington Heights Road, Suite 350, Itasca, IL 60143 PHONE: 888-539-3623 FAX: 630-285-1316
■ Regional offices
AL
Birmingham
CA
CA
N.California
Los Angeles
CO
FL
GA
IL
Denver
Tampa
Atlanta
Chicago
IN
KS
KY
MA
Indianapolis
Kansas City
Louisville
Boston
MI
MI
MN
MO
Detroit
Grand Rapids
Minneapolis
St. Louis
NJ
NY
NC
NC
Elmwood Park
Rochester
Charlotte
Raleigh
OH
OH
OR
PA
Cincinnati
Cleveland
Portland
Philadelphia
SC
TN
TN
TX
Greenville
Knoxville
Nashville
Austin
TX
VA
WA
Dallas
Richmond
Seattle
KEYENCE CANADA INC.
Head Office PHONE: 905-696-9970 FAX: 905-696-8340 E-mail: [email protected]
Montreal PHONE: 514-694-4740 FAX: 514-694-3206
KEYENCE GLOBAL HEADQUARTERS
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: +81-6-6379-2211
KEYENCE MEXICO S.A. DE C.V.
PHONE: +52-81-8220-7900 FAX: +52-81-8220-9097
E-mail: [email protected]
KA1-1090
The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice.
Copyright (c) 2009 KEYENCE CORPORATION. All rights reserved.
GT2-KA-C2-E 1011-6 611176 Printed in Japan
* 6 1 1 1 7 6 *