GT2 Air Push Type

Add to my manuals
32 Pages

advertisement

GT2 Air Push Type | Manualzz

NEW

High-Accuracy Digital Contact Sensor

GT2 Series

GT2

Air Push Type

Air push models for stable operation with easy mounting.

Revolutionary technology enables high-accuracy measurement

[Worlds First!]

2

The new GT2 Series provides even higher “error free” accuracy

Adopting the world's fi rst, ground-breaking scale-shot system, the new GT2 Series provides high-accuracy, without speed errors.

KEYENCE's long history of innovation and cutting edge technologies come together in the new GT2 Series.

Formed through a prism

LED parallel light illumination

Free from deformation

Quartz glass scale

Detachable Cable

Approx. 6 µs shutter speed

CMOS sensor

Advantages of the conventional scale method (pulse counting)

High-accuracy throughout the entire measurement range

Good temperature characteristics

Advantages of the conventional transformer method

No tracking errors

Absolute position detection

KEYENCE introduces new technology

World’s fi rst

Transmitter

Absolute value scale

CMOS sensor

The world’s fi rst, high-speed scale shot* system using a CMOS sensor that scans the absolute value glass scale incorporating different patterns depending on the position

* Shutter speed: Approx. 6 µs, Sampling interval: 1 ms

Highest accuracy in its class

Absolute system

Resolution

0.1

μm

0.004

Mil

Accuracy

1

μm

0.04

Mil

3

Tough and Rugged

[ Maintenance cost reduction ]

Long life

Detecting durability: 20 million times

*

Linear ball bearings are used for the spindle to ensure a long service life.

* GT2-H12 (L/K/KL), Typical

Strong rubber

Linear ball bearing used

Water resistant cable

IP67 enclosure rating

Even the connector meets the IP67 enclosure rating based on the IEC/JIS standards

* Except for the low stress type

Connector type

4

Strength against bending

Flexible free-cut robot cable

The sensor head cable uses a robot cable that withstands continuous bending.

Load (W): 250 g

Bend radius: 50 mm 1.97"

Bending rate: 30 times/minute

(1 time includes left to right to

Free cut: can be cut to length

R

90°

Withstands bending

20 million times without breaking (Typical usage)

W

The cable can be cut anywhere.

Free-cut

Easy Sensor Head Installation and Setup

[ Reduction in the number of installation/setup steps ]

Easy installation with a special bracket

Conventional method

GT2

Mounting made easy simply by drilling a

10 mm 0.39" hole.

A slotted jig must be prepared by the user.

Large indicators are convenient when setting up several units.

Flashing lights

The user can easily identify an operating sensor head.

Simple Tolerance Setting

[ Fewer steps for setup ]

First, set the reference.

Enter the tolerance value based on the master target to complete setup.

Example: Enter 0.010.0

A 0.01 mm

0.0004" tolerance range is automatically set.

Press the PRESET button to set to 0.

5

6

Easy Amplifi er Installation and Setup

[ Fewer steps for installation/setup ]

Select the best display unit according to the application

DIN-rail mount

Compact, panel mount

Large display panel mount

Pulse output

GT2-71N/71P

Easy mounting anywhere

GT2-75N/75P

For mounting in a nearby enclosure

Note: For the DIN-rail mounting type, a connector type and an analog output type are also available.

GT2-100N/100P

Easy-to-see large display

Features of the large display type

Easy operation with large display and large buttons

Double the size of a standard display

[Character height:

14 mm 0.55" ]

Large display

GT2-71D

For outputting position data as pulses

A single unit can connect several sensor heads

(11 heads max.).

Power supply terminal block

Standard I/O (20-pin MIL connector, male)

Easy preset operation

Large button

The selected

ID number lights in red.

W: 159.5 mm

6.28"

H: 79.8 mm

3.14"

Easy selection with the dedicated button

Sensor head selection button

Easy viewing of each individual head’s OK/NG and connection status. (OK/NG status is indicated by red or green, connection status is indicated by a blinking LED.)

Expansion board I/O

(30-pin MIL connector, male)

Communication unit connection port

Installing the expansion board

The expansion board allows for connection of up to 11 sensor heads.

Features of the pulse output (line driver output) type

Outputs the spindle position data

Pulse frequency selection

[10/50/100/500 kHz]

The maximum pulse frequency can be selected according to the input device. The absolute detection ensures accurate position data output to an external device without tracking errors even when a slow pulse frequency is selected.

Pulse output amplifi er unit

GT2-71D

Increment/decrement direction

Resolution

Pulse width

All position data can be output together.

The absolute detection allows the output of all pulses from the origin to the measurement point without origin return at power-up. Moreover, the operation is free from tracking errors.

Total cost reduction

[ Simplifi ed confi guration eliminates the need for analog I/O cards and tedious PLC programming ]

Analog I/O card not necessary

No additional equipment required

Forget about the tedious PLC programming that existing LVDT’s required, the GT2 Series does everything automatically. In addition, the user can save money by eliminating the analog I/O card from the budget.

Conventional Method

Diffi cult and time consuming way:

Done

Display Analog card PLC programming

GT2 Solution

Easy way:

Done

Easy way:

Done

Push-button setup

HH, HI, GO, LO, LL discrete outputs

Featuring 5 digital comparator outputs (HH, HI, GO, LO and LL), the GT2 Series can be set up in minutes, not hours.

Push-button calibration will leave the user wondering why they hadn’t switched to the GT2 Series sooner.

HH

HI

GO

LO

LL

Quickly select from up to 4 sets of HH/HI/LO/LL limits

Simple product changeover

Using channel select inputs on the GT2 Series, users can easily toggle between up to 4 different sets of HH/HI/LO/LL limits, skipping the extra PLC programming.

7

8

Detection of Jam Conditions

[ Current condition check ]

Sensor defect detection

Equipment status check displayed by a bar indicator

Maintenance needed

HI Limit

Normal

Maintenance needed

Safe detection

LO Limit

Fully extended

Jammed

The sensor outputs in the event of a jam when the sensor head is not fully extended.

In actual operation, it is diffi cult to read a displayed value when it changes quickly. With the bar indicator the equipment status can be easily read without reading a displayed value.

Calculations made simple

[ Fewer steps for setup ]

When several amplifi ers are connected, the GT2 Series can do automatic calculation simply by selecting a calculation mode.

Thickness

[Shaft diameter measurement]

Positioning the target between two sensor heads will display the outer diameter.

Main unit Expansion unit

Calculation result

Degree of fl atness

Reference difference

[Flatness check]

By subtracting the minimum value from the maximum value the fl atness will be displayed.

Main unit

Expansion unit

Expansion unit

Expansion unit

Maximum value

Minimum value

Calculation result

[Determining pin height]

The height difference of a reference value can be displayed by subtracting the value of the main unit (reference) from the value of the Expansion unit.

Expansion unit Main unit

Calculation result

Versatile detection modes support all applications

Single head

STD P-H B-H P-P

Multiple heads/when additional amplifi er units are installed (Application modes)

Maximum Minimum

Degree of fl atness

Average

Reference difference

Twist Warpage Thickness

Standard Peak hold Bottom hold Peak to peak

* For details regarding the calculation modes, refer to P.30.

Air push type extends the spindle and measures.

[ Easy to set up and saves space. ]

The air push type is part of the high-accuracy digital sensor GT2 Series.

A mechanism to move the sensor head is not necessary since it is possible to measure with a fi xed sensor head, saving space and reducing labor.

Jigs and mechanisms to move the sensor are no longer necessary.

Standard type

Linear guide

Dividing jig

Stopper

Air push type

Measuring range

50

mm

1.97"

Measuring range

Measuring range

32

1.26"

mm

Measuring range

12

mm

0.47"

GT2-A32

Accuracy: 3 µm 0.12 Mil (p-p)

12

mm

0.47"

GT2-A12

General purpose type

Accuracy: 2 µm 0.08 Mil (p-p)

GT2-A12K

High-accuracy type

Accuracy: 1 µm 0.04 Mil (p-p)

GT2-A50

Accuracy: 3.5 µm 0.14 Mil (p-p)

All jigs unnecessary.

A complex jig is not necessary since there is no sensor head movement. In addition, errors in accuracy due to jigs have been eliminated.

Installation is quick and easy.

A dividing jig is unnecessary.

Air is supplied.

Dedicated installation metal fi ttings.

Only needs a ø10 mm

ø0.39" hole. *

1

ø4 mm

ø0.16" outside diameter air tube.

Point 1

Spindle compressed in its usual state

GT2 Conventional spindle is usually stretched damag e

Point 2

Measuring force is unaffected by the amount of air pressure.

*1 For the 32 mm 1.26" and 50 mm 1.97" type, open a ø14 mm ø0.55" hole.

With the GT2, the spindle moves to the origin when it is not being supplied with air. Even if there is a problem or a condition arises where air is not being supplied, it is safe.

Due to the pressure free construction where air pressure is not directly applied to measurement parts, it is also safe to use with easily damaged workpieces.

9

10

Versatile detection modes support all applications

Single head

STD P-H B-H P-P

Standard Peak hold Bottom hold Peak to peak

Multiple heads

Maximum Minimum

Degree of fl atness

Average

Reference difference

Twist Warpage Thickness

Measurement of defects in a press fi t

Packing insertion check

Confi rms that targets are properly seated.

Shaft diameter measurement

Board warpage detection

Confi rms if the workpiece warpage meets the acceptable limits.

Detecting twist

Judges if the workpiece twisting falls within acceptable limits.

Flatness measurement of an engine block

Thickness measurement of a liquid crystal substrate

Parallel measurement of a wafer

Thermal expansion measurement of a machine tool

Thickness measurement of a steel plate

Warp measurement of a mechanical chassis

Volume measurement of a cam lift

Measurement of a transmission mount

Detection of crank shaft runout

11

How to select a GT2 Series sensor

Follow the steps below to select the GT2 Series sensor best suited to your operating environment from the wide range of units and accessories.

step

1 Sensor head

Standard Type step

1

Sensor head

step

2

Sensor head cable

step

3

Mounting bracket

step

4 step

5

Display unit

(Amplifi er unit)

Display unit options

step

6

Contact

step

7 step

8

Communication unit

Communication unit options

GT2 Series LINE-UP

step

2 Sensor head cable

Air push Type

NEW

step

5

Display unit options

12 mm 0.47" range

High-accuracy sensor head

GT2-H12K

12 mm 0.47" range

High-accuracy, low stress sensor head

GT2-H12KL step

3 Mounting bracket

12 mm 0.47" range

High-accuracy sensor head

12 mm 0.47" range

High-accuracy, low stress sensor head

GT2-A12K GT2-A12KL step

4 Display unit step

6 Contact

DIN-rail mount type

Amplifi er unit

GT2-71N / 71P step

7

Communication unit

BCD Output unit

DL-RB1A

12 mm 0.47" range

General-purpose sensor head

GT2-H12

12 mm 0.47" range

General-purpose, low stress sensor head

GT2-H12L

12 mm 0.47" range

General-purpose sensor head

GT2-A12

12 mm 0.47" range

General-purpose, low stress sensor head

GT2-A12L

Panel mount type

Compact amplifi er unit

GT2-75N / 75P

RS-232C

Communication unit

DL-RS1A

Panel mount type

Large display amplifi er unit

GT2-100N / 100P step

8 Communication unit options

DIN-rail mount type

Pulse output amplifi er unit

GT2-71D

32 mm 1.26" range

General-purpose sensor head

GT2-H32

32 mm 1.26" range

General-purpose, low stress sensor head

GT2-H32L

32 mm 1.26" range

General-purpose sensor head

GT2-A32

12

50 mm 1.97" range

General-purpose sensor head

GT2-H50

50 mm 1.97" range

General-purpose sensor head

GT2-A50

How to select a GT2 Series

step step

1

First, select a sensor head.

Required

The sensor head is determined by the measuring range, force, and accuracy.

Standard Type

Commonly used type

12 mm

0.47"

range

For 20 µm 0.79 Mil or less tolerance differentiation

High-accuracy Type

Resolution: 0.1 µm 0.004 Mil

Accuracy: 1 µm 0.04 Mil (P-P)

High-accuracy type sensor head

GT2-H12K

High-accuracy / Low stress type sensor head

GT2-H12KL

Low stress type

When particularly highaccuracy is not required

General-purpose Type

Resolution: 0.5 µm 0.02 Mil

Accuracy: 2 µm 0.08 Mil (P-P)

General-purpose type sensor head

GT2-H12

General-purpose / Low stress type sensor head

GT2-H12L

For a wider measuring range

32 mm

1.26"

range

Resolution: 0.5 µm 0.02 Mil

Accuracy: 3 µm 0.12 Mil (P-P)

General-purpose type sensor head

GT2-H32

General-purpose / Low stress type sensor head

GT2-H32L

Low stress type

For a larger target

50 mm

1.97"

range

Resolution: 0.5 µm 0.02 Mil

Accuracy: 3.5 µm 0.14 Mil (P-P)

General-purpose type sensor head

GT2-H50

The low stress type is not available for the 50 mm 1.97" range sensor head.

Low stress type

The low stress type does not require a dust boot.

What is the low stress type?

The low stress type uses a low repulsion force spring to reduce the pressure on the target. When using a target that can be easily deformed or damaged, select this type.

Measuring range

Type of accuracy Measuring force

12 mm 0.47"

32 mm 1.26"

50 mm 1.97"

High-accuracy

General-purpose

General-purpose

* Value at center of measuring range.

Standard

Low stress

Standard

Low stress

Standard

Low stress

Standard

Resolution

0.1 µm

0.5 µm

0.004 Mil

0.02 Mil

Accuracy

1 µm

2 µm

0.04 Mil

0.08 Mil

0.5 µm 0.02 Mil

3 µm 0.12 Mil

3.5 µm 0.14 Mil

Downward mounting

Measuring force*

Side mounting

1.0 N

0.4 N

0.9 N

0.3 N

1.0 N

0.4 N

2.1 N

1.2 N

3.2 N

0.9 N

0.3 N

1.8 N

0.9 N

2.8 N

Upward mounting

0.8 N

0.2 N

0.8 N

0.2 N

1.5 N

0.6 N

2.4 N

Model

GT2-H12K

GT2-H12KL

GT2-H12

GT2-H12L

GT2-H32

GT2-H32L

GT2-H50

Dust boot (optional accessory for replacement)

Appearance Applicable sensor head

GT2-H12

GT2-H12K

GT2-H32

GT2-H50

Model

OP-84332

OP-84459

OP-84460

13

14

How to select a GT2 Series

step

Air Push Type

NEW

Commonly used type

12 mm

0.47"

range

For 20 µm 0.79 Mil or less tolerance differentiation

High-accuracy Type

Resolution: 0.1 µm 0.004 Mil

Accuracy: 1 µm 0.04 Mil (P-P)

High-accuracy type sensor head

GT2-A12K

High-accuracy / Low stress type sensor head

GT2-A12KL

Low stress type

When particularly highaccuracy is not required

General-purpose Type

Resolution: 0.5 µm 0.02 Mil

Accuracy: 2 µm 0.08 Mil (P-P)

General-purpose type sensor head

GT2-A12

General-purpose / Low stress type sensor head

GT2-A12L

For a wider measuring range

32 mm

1.26"

range

Resolution: 0.5 µm 0.02 Mil

Accuracy: 3 µm 0.12 Mil (P-P)

General-purpose type sensor head

GT2-A32

The low stress type is not available for the 32 mm 1.26" range sensor head.

For a larger target

50 mm

1.97"

range

Resolution: 0.5 µm 0.02 Mil

Accuracy: 3.5 µm 0.14 Mil (P-P)

General-purpose type sensor head

GT2-A50

The low stress type is not available for the 50 mm 1.97" range sensor head.

Low stress type

Measuring range

Type of accuracy Measuring force

High-accuracy

12 mm 0.47"

General-purpose

32 mm 1.26"

50 mm 1.97"

General-purpose

* Value at center of measuring range.

Standard

Low stress

Standard

Low stress

Standard

Standard

Resolution

0.1 µm 0.004 Mil

Accuracy

1 µm 0.04 Mil

0.5 µm 0.02 Mil

0.5 µm 0.02 Mil

2 µm 0.08 Mil

3 µm 0.12 Mil

3.5 µm 0.14 Mil

Downward mounting

Measuring force*

Side mounting

1.2 N

0.4 N

1.2 N

1.1 N

0.3 N

1.1 N

0.4 N

2.1 N

3.2 N

0.3 N

1.8 N

2.8 N

Upward mounting

1.0 N

0.2 N

1.0 N

0.2 N

1.5 N

2.4 N

Model

GT2-A12K

GT2-A12KL

GT2-A12

GT2-A12L

GT2-A32

GT2-A50

Adjustable spindle speed

The speed controller (optional) allows the spindle movement speed to be adjusted.

Speed controller

OP-82133

step step

2

Select a sensor head cable

Required

Select the sensor head cable according to installation conditions and the distance between the sensor head and the display unit (amplifi er).

The L-shaped type can be used for the 12 mm 0.47" range sensor head (GT2-H12/A12) only.

Cable connection

Commonly used type

Straight Type

Cable connection

For space-saving installation

L-shaped Type

This connector does not rotate.

It is fi xed in the direction as shown in the photo (left).

Type

Straight

L-shaped

Applicable to

12 mm 0.47" range type only

Appearance Cable length

2 m 6.6'

5 m 16.4'

10 m 32.8'

20 m 65.6'

2 m 6.6'

5 m 16.4'

10 m 32.8'

20 m 65.6'

Model

GT2-CH2M

GT2-CH5M

GT2-CH10M

GT2-CH20M

GT2-CHL2M

GT2-CHL5M

GT2-CHL10M

GT2-CHL20M

Weight

Approx. 80 g

Approx. 190 g

Approx. 360 g

Approx. 680 g

Approx. 80 g

Approx. 190 g

Approx. 360 g

Approx. 680 g

The cable can be freely cut. If the cable is cut, a connector (OP-84338) is required to connect to the display unit (amplifi er).

This connector is required if the cable is cut.

The cable can be cut anywhere.

Connector used to connect to a display

unit (2 pcs.) OP-84338

step

3

Select mounting brackets as required.

Select a mounting bracket depending on the sensor head mounting method.

For GT2 12 mm

0.47"

range models

Commonly used type

Mounting Bracket A

OP-76874

Vibration resistant, Reinforced holding force

Mounting Bracket C

OP-84396

After drilling a ø10 mm ø0.39" hole, insert the sensor head through the hole, and fasten it.

For side mounting

Mounting Bracket B

Horizontally mounts the sensor head.

OP-76875

For GT2 32 mm

1.26"

and 50 mm

1.97"

range models

Vibration resistant, Reinforced holding force

Mounting Bracket D

OP-84327

After drilling a ø14 mm ø0.55" hole, insert the sensor head through the hole and fasten it.

* The mounting method is the same as mounting brackets A and C.

* When using the GT2-H32L with its contact probe directing upward, use the mounting holes in the sensor housing.

15

16

How to select a GT2 Series

step step

4

Next, select a display unit (amplifi er).

Required

After selecting a display unit depending on the mounting method, select optional accessories as required.

Easy installation in any place

DIN-rail Mount Type

Commonly used type

Loose wire type

Easy installation/replacement

Connector type

Connecting additional expansion units

Use the connector on the side of the unit.

Main unit

Expansion unit

GT2-71N/71P GT2-71CN/71CP

Connector

To connect an additional unit, purchase the optional end unit (OP-26751).

For each main unit, up to 14 expansion units can be connected.

When several units are connected, a power supply cable is not required for the expansion units. The GT2 Series can be connected with the GT Series. However, the maximum number of connectable units is 10 units

(including main unit).

Unit expansion is not possible for the

GT2-71D.

Loose wire

Connector*

Type

Main unit

Standard

Expansion unit

Pulse output

Standard

Analog

Standard

Main unit

Expansion unit

Model

NPN output PNP output Line driver output

GT2-71N GT2-71P

GT2-72N

GT2-72CN

GT2-72P

GT2-71CN GT2-71CP

GT2-71MCN GT2-71MCP

GT2-72CP

GT2-71D

* When the connector type amplifi er unit is used, an optional socket cable should be purchased separately (See the next page.).

The analog output type amplifi er unit provides three discrete outputs.

Installation on easy-to-see places

Panel Mount Type

Commonly used type

Compact type

Easy-to-see display for easier operation

Large display type

Connecting additional main and expansion units

[Compact type only]

Connect using the cable supplied with the expansion unit.

Expansion cable

To connect additional units, place the main unit in the top position and connect the expansion units below

(vertically).

* For horizontal installation, the optional expansion cable

(OP-35361, 300 mm 11.81" ) is required. For details, refer to the description in the option list.

For the compact type amplifi er unit, up to 14 expansion units can be connected to one main unit without providing power supply cables individually. The expansion connection can include the GT Series, however, the maximum number of connectable units is limited to 10 including the main unit.

GT2-75N/75P

W: 66 mm 2.60" H: 23.9 mm 0.94"

GT2-100N/100P

W: 159.5 mm 6.28" H: 79.8 mm 3.14"

Compact

Type

Main unit

Expansion unit

Model

NPN output PNP output

GT2-75N GT2-75P

GT2-76N

GT2-100N

GT2-76P

GT2-100P Large display*

* When these amplifi er units are not mounted to a panel, an optional mounting bracket should be purchased separately (See the next page.).

A single unit of the large display type can connect two sensor heads.

When the optional expansion boards are used, up to 11 sensor heads can be connected. For the details of the expansion board, see the next page.

step step

5

Select the optional accessories for the display unit as required.

Select the optional accessories according to the display unit selected in Step 4.

Optional accessories for the GT2-71/72

(DIN-rail mount)

Description Type

For installation without a DIN-rail

Mounting Bracket for DIN-rail mount Type Display unit

(optional accessory for main unit)

The amplifi er can be mounted without using a

DIN-rail.

Amplifi er mounting bracket

End unit

End unit

Required for connecting additional units

End unit

(Optional)

To connect an additional expansion unit, use the end units to secure the display units on both ends. When connecting additional units, be sure to use the end units. (2 pcs.)

Required when the connector type is used

Socket cable

2 m 6.6' /10 m 32.8'

(Optional)

Used to connect the connector type display unit.

Since the amplifi er unit does not include the socket cable, it must be purchased separately.

Model

OP-76877

OP-26751

GT2-CA2M

(2 m 6.6' )

GT2-CA10M

(10 m 32.8' )

Optional accessories for the GT2-75/76

(panel mount, compact)

Description Type

Standard equipment

Panel mounting bracket

(Included in panel mount type amplifi er)

The panel mounting bracket is included in the panel mount type amplifi er.

If the supplied bracket is lost or damaged, order a new bracket.

If the standard cable length is not enough

Expansion cable:

300 mm 11.81"

(Optional)

Extension cable used for panel mount type amplifi er.

Use this cable if the standard 50 mm 1.97" cable is not long enough.

Up to 4 extension cables can be used at once. However, if an extension cable is used, the number of expansion units that can be connected to a single main unit is limited to 4 units.

Model

OP-84394

OP-35361

Optional accessories for the GT2-100

(panel mount, large display)

Type

To connect three or more sensor heads

Expansion board

For GT2-100N

(Optional)

For GT2-100P

(Optional)

Description

Installing this expansion board into the GT2-

100 allows you to connect more than two sensor heads. Since one expansion board allows connection of one to three sensor heads, the maximum of 11 sensor heads can be connected in total.

No. of sensor heads

1 or 2

3 to 5

6 to 8

9 to 11

No. of expansion boards

None

1

2

3

Model

GT2-E3N

(NPN)

GT2-E3P

(PNP)

To install the GT2-100 on a workbench, etc.

Mounting bracket

(Optional)

I/O connector

20-pin MIL connector

(for the amplifi er unit, optional)

30-pin MIL connector

(for the expansion board, optional)

Contact for maintenance work

(Optional)

Small diameter contact

(Optional)

Special crimping tool

(Optional)

When the amplifi er unit is not mounted to a panel, use this mounting bracket to secure it.

A set of connector and contacts (for AWG 24 to 22).

The cable should be prepared by the user.

For AWG 24 to 22, Package of 200

For AWG 28 to 26, Package of 200

Use this tool to crimp the contact.

Secure the amplifi er unit with M4 screws.

OP-84331

OP-22185

(20-pin)

OP-84456

(30-pin)

OP-22186

OP-30594

OP-21734

17

18

How to select a GT2 Series

step step

6

Select a contact as needed.

The standard type and carbide type contacts are included in the GT2-H12 (L) / H32 (L) / H50 / A12 (L) / A32 / A50 and the GT2-H12K (L) /

A12K (L) respectively, as standard equipment. Other types of contacts are optionally available. Select optional contacts as required.

For standard measurement

Standard

OP-77678

Standard equipment of generalpurpose type sensor head

GT2-H12 (L) / H32 (L) / H50 /

A12 (L) / A32 / A50

For moving targets

Roller

(Optional)

OP-77680

The roller smoothly detects moving targets.

For measurement in narrow spaces

Needle

(Optional)

OP-77681

The needle contact is made of super-tough tungsten alloy.

Made from a carbide alloy – For high-accuracy measurement

Super-tough

OP-77682

Standard equipment of high-accuracy type sensor head GT2-H12K (L) / A12K (L)

To prevent damage to target

Fluorocarbon Resin

(Optional)

OP-80228

Made from material that is unlikely to damage the target’s surface.

For measurement at several points with small targets

Offset

(Optional)

OP-77683

Detecting points can be added in narrow range.

For targets with curved surfaces

Flat Plate

(Optional)

OP-77679

Ignore the contours of a target with a curved surface.

Electrically insulated from the target

Ceramic

(Optional)

OP-81970

Ceramic is used for the ball of the contact tip.

For 12.2 mm 0.48" spindle extension

Spacer

(Optional)

OP-77684

When lifting a spindle by hand

Lift lever

(Optional)

OP-84397 step

7

Select a communication unit as needed.

A communication unit is required to extract numerical data from the GT2 Series to an external device. With a single unit, data from up to 15

GT2 Series units can be extracted.

To extract BCD data

BCD Output

Unit

Detection data can be read from a specifi ed sensor amplifi er via an external device such as a PLC.

For RS-232C communication

RS-232C

Communication

Unit

Sensor amplifi er detection data, settings, and calculation results from several GT units can be read and amplifi er settings can be written via an external device such as a PLC or PC.

DATA

DATA

Reading

BCD output unit

DL-RB1A

Writing

Reading

RS-232C communication unit

DL-RS1A

Reading

Programmable controller

Programmable controller

PC

step step

8

Select the optional accessories for the communication unit as necessary.

Select the optional accessories according to the type of the communication unit selected in Step 7.

Optional accessories common to the DL-RB1A and DL-RS1A

Type Description Model

To install the unit without using a DIN-rail

Mounting bracket

The communication unit can be mounted without using a DIN-rail.

OP-60412

To connect the unit to the panel mount type display unit

Expansion cable:

300 mm 11.81"

(Optional)

Although the DL Series is designed for DIN-rail mounting only, the optional expansion cable

(OP-35361, 300 mm 11.81" )

Main unit

Expansion unit

Expansion unit enables communication with the panel mount type amplifi er unit

(compact/large display).

DL

Expansion cable

(300 mm 11.81" )

OP-35361

OP-35361

Optional accessories for the DL-RB1A

Type Description

I/O connector

34-pin vertical MIL connector

(Optional)

[40 contacts for AWG 24 to 22 included]

A set of connector and contacts (for AWG 24 to 22).

The cable should be prepared by the user.

I/O connector

34-pin slanting MIL connector

(Optional)

[40 contacts for AWG 24 to 22 and a cable tie included]

A set of connector and contacts (for AWG 24 to 22).

The cable should be prepared by the user.

Special crimping tool

(Optional)

Contact for maintenance work

(Optional)

Small diameter contact

(Optional)

Use this tool to crimp the contact.

For AWG 24 to 22, Package of 200

For AWG 28 to 26, Package of 200

Model

OP-23139

OP-42224

OP-21734

OP-22186

OP-30594

Optional accessories for the DL-RS1A

Type Description

D-sub 9-pin connector-to-loose wires cable

(5 m 16.4' , optional)

This cable can be used to connect the DL-RS1A to a personal computer or other serial device.

Model

OP-81283

19

Specifi cations

Sensor heads for the GT2 Standard Type

Model GT2-H12K

Type

GT2-H12KL GT2-H12 GT2-H12L

Standard / Low stress (L) type (Sensor head for 12 mm 0.47" )

GT2-H32 GT2-H32L GT2-H50

Standard / Low stress (L) type

(Sensor head for 32 mm 1.26" /50 mm 1.97" range)

Appearance

Detection system

Measuring range

Resolution

Accuracy (20°C 68°F )

Measuring force * 1

Downward mounting

Side mounting

Upward mounting

Mechanical response

Probe

Operation indicator

Environmental resistance

Enclosure rating

Ambient temperature

Relative humidity

Vibration

Sensor head cable

Main body

Materials

Contact

Weight (excluding cable)

Accessories

1.0 N

0.9 N

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

12 mm 0.47" 32 mm 1.26"

0.1 µm 0.004 Mil

1 µm 0.04 Mil (p-p)

0.4 N

0.3 N

2 µm

1.0 N

0.9 N

0.08 Mil (p-p)

0.4 N

0.3 N

0.5 µm 0.02 Mil

3 µm

2.1 N

1.8 N

0.12 Mil (p-p)

1.2 N

0.9 N

0.8 N

10 Hz

Carbide ball ø3

0.2 N

4 Hz

IP67

0.8 N

10 Hz

0.2 N

4 Hz

1.5 N

6 Hz

Steel ball ø3

0.6 N

5 Hz

– IP67

2-color LED (red, green)

– IP67 –

-10 to +55°C 14 to 131°F

35 to 85% RH (No condensation)

10 to 55 Hz, 1.5 mm 0.06" double amplitude, 2 hours in each of X, Y, and Z directions

Optional (M8 connector)

Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR * 2

TYPE304 Stainless steel, super-tough tungsten alloy

Approx. 95 g

TYPE304, 440C Stainless steel

Approx. 270 g

Refer to the instruction manual.

*1 Value at center of measuring range.

*2 A dust boot is not provided with the GT2-H12KL, the GT2-H12L or the GT2-H32L.

Sensor heads for the GT2 Air Push Type

Model

NEW

GT2-A12K

Type

NEW

GT2-A12KL

NEW

GT2-A12

NEW

GT2-A12L

Standard / Low stress (L) type (Sensor head for 12 mm 0.47" )

50 mm 1.97"

3.5 µm 0.14 Mil (p-p)

3.2 N

2.8 N

2.4 N

7 Hz

IP67

Approx. 320 g

NEW

GT2-A32

NEW

GT2-A50

Standard type (Sensor head for 32 mm 1.26" /50 mm 1.97" range)

Appearance

20

Detection system

Measuring range

Resolution

Accuracy (20°C 68°F ) * 1

Measuring force * 2

Upward mounting

Operation indicator

Applied pressure range

Pressure resistance

Environmental resistance

Downward mounting

Side mounting

Enclosure rating

Ambient temperature

Relative humidity

Vibration * 4

Sensor head cable

Materials

Main body

Dust boot

Contact * 5

1.2 N

1.1 N

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

12 mm 0.47" 32 mm 1.26"

0.1 µm 0.004 Mil

1 µm 0.04 Mil (p-p)

0.4 N

0.3 N

1.2 N

2 µm 0.08 Mil (p-p)

0.4 N

0.5 µm 0.02 Mil

3 µm 0.12 Mil (p-p)

2.1 N

1.8 N

1.0 N 0.2 N

1.1 N 0.3 N

1.0 N 0.2 N

2-color LED (red, green)

0.25 to 0.5 MPa

1.5 N

IP67 *

3

1.0 MPa

IP67 *

3

0 to 55°C 32 to 131°F

– IP67 *

3

35 to 85% RH (No condensation)

10 to 55 Hz, 1.5 mm 0.06" double amplitude, 2 hours in each of X, Y, and Z directions

Optional (M8 connector)

Main body case: Zinc die-casting; Cylinder part: Aluminium alloy;

Air joint resin part: Polyacetal; Air joint metal part: Brass nickel plating; Indicator: Polyarylate

– NBR – NBR NBR

TYPE304 Stainless steel, super-tough tungsten alloy

Approx. 145 g

TYPE304, 440C Stainless steel

Approx. 340 g

Refer to the instruction manual.

50 mm 1.97"

3.5 µm 0.14 Mil (p-p)

3.2 N

2.8 N

2.4 N

IP67 *

NBR

3

Approx. 405 g

Weight (excluding cable)

Accessories

*1 Value when ambient temperature is 20°C 68°F

*2 Value at center of measuring range.

Please note that the measurement force changes depending on the installation state of the dust boots.

*3 Make sure the air tube is connected to the air exhaust joint and that no foreign materials enter inside from the joint.

*4 In the case where a mounting bracket D is used with GT2-A32 and GT2-A50, the double amplitude becomes 0.75 mm 0.03" .

*5 The contact is included with the sensor.

DIN-rail mount type amplifi er unit (For the pulse output type, see page 19.)

Model

NPN output

PNP output

Mounting method

Type

Main unit / Expansion unit * 1

GT2-71N

GT2-71P

GT2-72N

GT2-72P

Standard loose wire type

Main unit Expansion unit

GT2-71CN

GT2-71CP

GT2-72CN

GT2-72CP

DIN-rail mount

Standard connector type

Main unit Expansion unit

Appearance

GT2-71MCN

GT2-71MCP

Analog output, connector type

Main unit

Power supply voltage * 1

Power consumption * 2

Normal

Power saving (Eco)

Display power

Measured value display

Other displays

Display range

Display resolution

Sampling rate

Timing input

Control input

Preset input

Reset input

Bank input

Control output

HH / High / Go /

Low / LL

Analog output

Response time

Ambient temperature

Environmental resistance

Relative humidity

Vibration

Materials

Weight

Accessories

10 to 30 VDC, including 10% ripple (P-P) 20 to 30 VDC, including 10% ripple (P-P)

2200 mW max. (30 V, 73.3 mA max.)

1700 mW max. (30 V, 56.7 mA max.)

2700 mW max. (30 V, 90 mA max.)

2200 mW max. (30 V, 73.3 mA max.)

6 + 1/2-digit 7-segment LED (red)

2-color, 13-level bar LED display (red, green), indicators (red, green)

-199.999.9 to 199.999.9

0.1 µm 0.004 Mil

1000 times/sec.

Input time: 2 ms min.

Input time: 20 ms min.

NPN/PNP open collector, Applicable current: 50 mA,

Maximum applicable voltage (NPN: 40 V, PNP: 30 V)

Residual voltage at ON: 1 V max. * N.O./N.C switchable

(GT2-71MCN/71MCP: HH and LL are not available.)

– hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s

-10 to +50°C 14 to 122°F (GT2-71MCN/71MCP: -10 to +45°C 14 to 113°F when expansion unit(s) is connected)

35 to 85% RH (No condensation)

4 to 20 mA, maximum load resistance: 350 Ω

Analog output range can be changed as desired.

10 to 55 Hz, 1.5 mm 0.06" double amplitude, 2 hours in each of X, Y, and Z directions

Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC

GT2-71N/71P/72N/72P: Approx. 140 g (including power cable), GT2-71CN/71CP/72CN/72CP/71MCN/71MCP: Approx. 70 g

GT2-71N/71P/71CN/71CP/71MCN/71MCP: Instruction manual, Cover seal, GT2-72N/72P/72CN/72CP: None

Panel mount type amplifi er unit

Model

NPN output

PNP output

GT2-75N

GT2-75P

Mounting method

Main unit / Expansion unit *

1

Main unit

Panel mount

GT2-76N

GT2-76P

Expansion unit

GT2-100N

GT2-100P

Panel mount/Screw mounting using optional mounting bracket

2 channels provided as standard. Addition of expansion boards allows expansion to 11 channels max.

GT2-E3N

GT2-E3P

Installed into GT2-100N/100P

(up to 3 boards)

Expansion unit (1 to 3 channels)

Appearance

Power supply voltage * 1

Power consumption *

2

Normal

Power saving (Eco)

Display power

Measured value display

Other displays

Display range

Display resolution

Sampling rate

Timing input

Preset input

Control input

Reset input

Bank input

10 to 30 VDC, including 10% ripple (P-P)

2200 mW max. (30 V, 73.3 mA max.)

1700 mW max. (30 V, 56.7 mA max.)

6 + 1/2-digit 7-segment LED (red)

2-color, 13-level bar LED display (red, green), indicators (red, green)

-199.999.9 to 199.999.9

0.1 µm 0.004 Mil

20 to 30 VDC, including 10% ripple (P-P)

4500 mW max. (30 V, 150 mA max.)

3600 mW max. (30 V, 120 mA max.)

1000 times/sec.

Input time: 2 ms min.

Input time: 20 ms min.

Supplied from GT2-100N/100P

4200 mW max. (30 V, 140 mA max.)

4000 mW max. (30 V, 133.3 mA max.)

Control output

Response time

Ambient temperature

Environmental resistance

Relative humidity

Materials

Vibration

Power supply / I/O cable

Weight

Accessories

HH / High / Go /

Low / LL

NPN/PNP open collector, Applicable current: 50 mA,

Maximum applicable voltage (NPN: 40 V, PNP: 30 V)

Residual voltage at ON: 1 V max. * N.O./N.C switchable

(Applicable current decreases to 20 mA or lower when 2 or more sensor heads are connected to the GT2-100 Series.) hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s

-10 to +50°C 14 to 122°F

35 to 85% RH (No condensation)

10 to 55 Hz, 1.5 mm 0.06" double amplitude, 2 hours in each of X, Y, and Z directions (GT2-100N/P: 0.15 mm 0.01" double amplitude)

– Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC (GT2-75N/75P/76N/76P only)

12-core connector connection (Connecting cable included)

Power supply: Terminal block,

I/O: 20-pin connector (MIL standard)

I/O: 30-pin connector (MIL standard)

GT2-75N/75P/76N/76P: Approx. 140 g (including panel mounting bracket, protective front cover and power cable)

GT2-100N/100P: Approx. 380 g, GT2-E3N/E3P: Approx. 80 g

GT2-75N/75P: Panel mounting bracket, protective front cover, power cable, instruction manual, cover seal

GT2-76N/76P: Panel mounting bracket, protective front cover, power cable, expansion cable

GT2-100N/100P: Instruction manual, panel mounting bracket, GT2-E3N/E3P: None

*1 Precautions when the GT2-70 Series is used with an expansion unit (excluding GT2-71D)

Up to 15 amplifi er units can be connected; main unit: 1 unit, expansion unit: 14 units. To use the DIN-rail mount type, be sure to mount the amplifi er unit to a DIN-rail (using the metal bracket). When mounting additional units, be sure to use the end units (OP-26751). When mounting additional units, depending on the number of units to be added, confi rm the following specifi cation limitations.

<Up to 8 units (including main unit)>

• The power supply voltage is 20 to 30 VDC.

<Up to 9 to 15 units (including main unit)>

• The power supply voltage is 20 to 30 VDC.

• The maximum applicable current for each output is 20 mA.

• The maximum applicable current for each output is 10 mA (including DL-RB1A output current).

• The residual voltage at ON Is 1.5 V or less.

*2 For GT2-100 Series, when the maximum number of sensor heads are connected and all units are set to power saving mode

21

22

Specifi cations

DIN-rail mount type pulse output amplifi er unit

Model GT2-71D

Appearance

Mounting method

Power supply voltage

Current consumption

Indicator

Pulse resolution

Minimum phase difference

Control input Origin return

Output signal

Output signal level

Environmental resistance

Ambient temperature

Relative humidity

Vibration

Material

Weight

Accessories

DIN-rail mount

10 to 30 VDC, including 10% ripple (P-P)

1600 mW (30 V, 53.3 mA max.)

Power supply (green)/Alarm (red) indicator, pulse output indicator (green), input indicator (green)

Selectable from 0.1 µm 0.004 Mil , 0.5 µm 0.02 Mil , 1 µm 0.04 Mil , and 10 µm 0.39 Mil (Factory setting: 0.5 µm 0.02 Mil )

Selectable from 0.5 µs, 2.5 µs, 5 µs, and 25 µs (Factory setting: 2.5 µs)

Input time: 20 ms min.

90° phase difference, differential square wave (EIA-422 compliant)

+5V, øA, øA-, øB, øB-, øZ, øZ-: Line driver output

-10 to +50°C 14 to 122°F

35 to 85% RH (No condensation)

10 to 55 Hz, 1.5 mm 0.06" double amplitude,

2 hours in each of X, Y, and Z directions

Main body case: Polycarbonate, Cable: PVC

Approx. 110 g (including power supply cable)

Instruction manual, SW protection sticker

Communication unit (Common specifi cations)

Model DL-RB1A DL-RS1A

Communication unit (DL-RS1A Communication Specifi cations)

Model DL-RS1A

Appearance Appearance

Power supply voltage

Power consumption

Number of connectable sensor amplifi ers

Indicator

Ambient temperature

Relative humidity

Environmental resistance

Vibration

Material

Weight

Accessories

20 to 30 VDC, including ripple,

Ripple (P-P): 10% max.

(Supplied via connected sensor amplifi er)

27 mA max. 25 mA max.

Up to 15 units (including main unit)

Alarm indicator lamp

(red),

Power indicator lamp

(green)

Communication indicator lamp

(green x 2),

Alarm indicator lamp

(red),

Power indicator lamp

(green)

-10 to +55°C 14 to 131°F

35 to 85% RH (No condensation)

10 to 55 Hz,

1.5 mm 0.06" double amplitude,

2 hours in each of X, Y, and Z directions

Main body case: Polycarbonate

Approx. 46 g Approx. 53 g

Instruction manual, End units (x 2),

Switch protection seal,

Expansion connector cover

Communication method

Synchronization method

Transmission code

Baud rate

Date bit length

Parity check

Stop bit length

Data delimiter

Full duplex

Start-stop

ASCII

2400/4800/9600/19200/38400 bps selectable

(Factory-setting: 9600 bps)

8-bit/7-bit selectable (Factory-setting: 8 bits)

None/Even/Odd selectable

(Factory- setting: None)

1 bit

Data reception: automatically recognizes CR or CR+LF

Data transmission: Fixed to CR+LF

Pin assignment for the DL-RB1A (BCD)

11

12

13

14

15

16

17

7

8

9

10

Pin No.

1

2

3

4

5

6

Signal name

IDSEL 1

IDSEL 2

IDSEL 3

IDSEL 4

DRQ

BCD DIGIT 1 (1)

BCD DIGIT 1 (2)

BCD DIGIT 1 (4)

BCD DIGIT 1 (8)

BCD DIGIT 2 (1)

BCD DIGIT 2 (2)

BCD DIGIT 2 (4)

BCD DIGIT 2 (8)

BCD DIGIT 3 (1)

BCD DIGIT 3 (2)

BCD DIGIT 3 (4)

BCD DIGIT 3 (8)

Description

ID No. selection input 1

ID No. selection input 2

ID No. selection input 3

ID No. selection input 4

Data request input

BCD 1st digit 1×10 0

BCD 1st digit 2×10 0

BCD 1st digit 4×10

0

BCD 1st digit 8×10

0

BCD 2nd digit 1×10 1

BCD 2nd digit 2×10 1

BCD 2nd digit 4×10 1

BCD 2nd digit 8×10

1

BCD 3rd digit 1×10 2

BCD 3rd digit 2×10 2

BCD 3rd digit 4×10 2

BCD 3rd digit 8×10 2

28

29

30

31

32

33

34

24

25

26

27

Pin No.

18

19

20

21

22

23

Signal name

BCD DIGIT 4 (1)

BCD DIGIT 4 (2)

BCD DIGIT 4 (4)

BCD DIGIT 4 (8)

BCD DIGIT 5 (1)

BCD DIGIT 5 (2)

BCD DIGIT 5 (4)

BCD DIGIT 5 (8)

BCD DIGIT 6 (1)

BCD DIGIT 6 (2)

BCD DIGIT 6 (4)

BCD DIGIT 6 (8)

BCD SIGN

BCD STB

ALARM

COM

COM

Description

BCD 4th digit 1×10

3

BCD 4th digit 2×10 3

BCD 4th digit 4×10 3

BCD 4th digit 8×10

3

BCD 5th digit 1×10

4

BCD 5th digit 2×10 4

BCD 5th digit 4×10 4

BCD 5th digit 8×10

4

BCD 6th digit 1×10

5

BCD 6th digit 2×10 5

BCD 6th digit 4×10 5

BCD 6th digit 8×10 5

BCD data polarity sign

Strobe output

Alarm output

Common

Common

15 16

17 18

19 20

21 22

23 24

25 26

27 28

29 30

31 32

33 34

1 2

3 4

5 6

7 8

9 10

11 12

13 14

Input/Output Circuits

I/O circuit (GT2-71N/72N/71CN/72CN/71MCN/75N/76N)

Input circuit

Brown * 1

10 to 30 VDC * 3

Orange (HH output) * 2

Load

Black (HI output)

Load

Gray (GO output)

Load

5 to 40 VDC

5 to 40 VDC

5 to 40 VDC

White (LO output)

Load

5 to 40 VDC

Green (LL output) * 2

Load 5 to 40 VDC

Blue *

1

0 V

Pink, purple, pink/purple, yellow, red * 4

External input

External input circuit

5VDC

(Short-circuit current: 1 mA max.)

Blue *

1

Pink: Preset input

Purple: Bank A input

Pink/purple: Timing input

Yellow: Bank B input

Red: Reset input

I/O circuit (GT2-71P/72P/71CP/72CP/71MCP/75P/76P)

Input circuit

Brown *

1

Orange (HH output) * 2

Black (HI output)

Gray (GO output)

White (LO output)

Green (LL output) * 2

Load

Blue * 1

Load

Load

Load

Load

Pink, purple, pink/purple, yellow, red * 4

10 to 30 VDC * 3

0 V

External input

External input circuit

(Short-circuit current: 2 mA max.)

10 to 30 VDC

Brown * 1

Pink: Preset input

Purple: Bank A input

Pink/purple: Timing input

Yellow: Bank B input

Red: Reset input

*1 Brown and blue are applicable only to main units (GT2-71N/71P/71CN/71CP/71MCN/71MCP/75N/75P). Not to expansion units (GT2-72N/72P/72CN/72CP/76N/76P).

The connector type expansion unit (GT2-72CN/72CP) is not connected to the internal circuit.

*2 The orange and green cables are used as analog output cables for the analog type amplifi er unit (GT2-71MCN/71MCP).

For details, refer to the analog output circuit diagram.

*3 20 to 30 VDC when expansion unit is connected or for the analog type amplifi er unit (GT2-71MCN/71MCP).

*4 For details on external input, refer to the external input circuit diagram.

Analog output circuit

GT2-71MCN/71MCP

Orange

Green *

Analog output

(4 to 20 mA)

0 V (for analog)

* The green and blue cables are common internally.

Pulse output amplifi er unit (GT2-71D)

I/O circuit

5 VDC

33 Ω

33 Ω

Input circuit

Brown

10 to 30 VDC

Black, white, orange

Purple, gray,

Black: Phase A, White: Phase

B, Orange: Phase Z green

Purple: Reversed phase A

Gray: Reversed phase B

Green: Reversed phase Z

Blue

0 V

Pink *

Input

External input circuit

5 VDC

(Short-circuit current: 1 mA max.)

Pink

Blue

* For details of the external input, refer to the diagram of the external input circuit.

Recommended input device

AM26LS32 line receiver or equivalent device

390 Ω

Output circuit of the large display amplifi er unit

GT2-100N/GT2-E3N

(Pin Nos. 1 to 5, 11 to 15, 21 to 25)

+ *

20 to 30 VDC

1 to 5, 11 to 15, 21 to 25

Load 5 to 40 VDC

- *

0 V

* The +/- terminals are provided in the GT2-100N only.

They are not provided in the GT2-E3N.

Output circuit of the large display amplifi er unit

GT2-100P/GT2-E3P

(Pin Nos. 1 to 5, 11 to 15, 21 to 25)

+ *

20 to 30 VDC

1 to 5, 11 to 15, 21 to 25

Load

- *

0 V

* The +/- terminals are provided in the GT2-100P only.

They are not provided in the GT2-E3P.

Input circuit of the large display amplifi er unit

GT2-100N/GT2-E3N

(Pin Nos. 6 to 10, 16 to 20, 26 to 30)

5 VDC

6 to 10, 16 to 20, 26 to 30

- *

(Short-circuit current: 1 mA max.)

* The - terminal is provided in the GT2-100N only.

It is not provided in the GT2-E3N.

Input circuit of the large display amplifi er unit

GT2-100P/GT2-E3P

(Pin Nos. 6 to 10, 16 to 20, 26 to 30)

20 to 30 VDC

+ *

(Short-circuit current: 2 mA max.)

6 to 10, 16 to 20, 26 to 30

* The + terminal is provided in the GT2-100P only.

It is not provided in the GT2-E3P.

For details of the I/O connector pin assignment and the expansion board, refer to the instruction manual. The information is also available at the KEYENCE home page. www.keyence.com

23

24

Dimensions

Sensor head (Standard)

GT2-H12K/GT2-H12

ø8

ø0.31"

1.10"

28

0.61"

15.5

M8 cable connector

0.63"

16

(0.49")

(12.5)

5.9

(6.4) (0.25")

0.23"

(10.1)

(0.40")

Cable connection

(Straight)

ø0.37" ø9.5

0.42"

10.7

0.05"

1.15

(58)

(2.28")

66.7

73.1

2.63" 2.88"

0.24"

6

ø8 ø0.31" h5

( )

-0.006

( )

ø11.6

ø0.46"

8.7

0.34"

15.1

0.59"

41.5

to

29.0

45.3

to

32.8

1.63" to

1.78" to

1.14"

1.29"

(22)

(0.87")

3.8

0.15"

6.4

0.25"

ø4 ø0.16"

(9.6)

(0.38")

95.3

3.75"

Unit: mm inch

Cable connection

(L-shaped)

1.15

0.05"

ø9.5

ø0.37"

9

0.35"

0.80"

20.2

3.05

0.12"

92.3

3.63"

Sensor head (Low stress)

GT2-H12KL/GT2-H12L

ø8

ø0.31"

1.10"

28

0.61"

15.5

M8 cable connector

0.63"

16

(0.49")

(12.5)

5.9

(6.4) (0.25")

0.23"

(10.1)

(0.40")

Cable connection

(Straight)

ø0.37" ø9.5

0.42"

10.7

0.05"

1.15

(58)

(2.28")

66.7 73.1

2.63" 2.88"

95.3

3.75"

0.24"

6

ø8 ø0.31" h5

( )

-0.006

( )

ø11.6

ø0.46"

8.7

0.34"

15.1

0.59"

41.5

to

29.0

45.3

to

1.63" to

32.8

1.78"

1.14" to

1.29"

(22)

(0.87")

3.8

0.15"

6.4

0.25"

ø4 ø0.16"

(9.6)

(0.38")

Sensor head (Standard)

GT2-H32

0.70"

17.8

1.48"

37.6

0.99"

25.1

(12.5) (0.49")

(19.8) (0.78")

ø8

ø0.31"

(6.4) (0.25")

M8 cable connector

8.15

0.32"

2-ø4.3

ø0.17"

ø12 ø0.47"

116.4

4.58"

0.91"

23

0.34" 8.7

5.9 0.23"

h6

ø15

ø0.59"

30

1.18"

0.48"

12.2

(53.3)

(2.10")

0.38"

9.7

(0.56")

(88.5)

(3.48")

90.9

3.58"

97.3

3.83"

(14.3)

27.9 1.10"

0.15"

3.8

17 0.67"

2.4

(17.8)

(0.70")

0.09"

43.8

to

77.8

1.72" to

3.06"

47.6

to

81.6

1.87" to

3.21"

(25.4) (1.00")

ø0.20"

ø5

12.2

0.48"

0.78"

19.7

(11.55)

(0.45")

0.3

20

0.01"

0.79"

(7.8) (0.31")

Cable connection

(Straight)

3.4

0.13"

Cable connection

(L-shaped)

1.15

0.05"

ø9.5

ø0.37"

9

0.35"

0.80"

20.2

3.05

0.12"

92.3

3.63"

ø9.5

ø0.37"

119.5

4.70"

20.35

0.80"

Sensor head

(Low stress)

GT2-H32L

0.70"

17.8

1.48"

37.6

0.99"

25.1

(12.5) (0.49")

(19.8) (0.78")

ø8

ø0.31"

(6.4) (0.25")

M8 cable connector

8.15

0.32"

2-ø4.3

ø0.17"

ø12 ø0.47"

116.4

4.58"

0.91"

23

0.34" 8.7

5.9 0.23"

h6

ø15

ø0.59"

30

1.18"

0.48"

12.2

(53.3)

(2.10")

0.38"

9.7

(0.56")

(88.5)

(3.48")

90.9

3.58"

97.3

3.83"

(14.3)

27.9 1.10"

0.15" (0.70")

3.8

17 0.67"

2.4

0.09"

(17.8)

43.8

to

77.8

1.72" to

3.06"

47.6

to

81.6

1.87" to

3.21"

(25.4) (1.00")

ø0.20"

ø5

12.2

0.48"

0.78"

19.7

(11.55)

(0.45")

0.3

20

0.01"

0.79"

(7.8) (0.31")

Cable connection

(Straight)

3.4

0.13"

ø9.5

ø0.37"

119.5

4.70"

20.35

0.80"

Unit: mm inch

Sensor head (Standard)

GT2-H50

0.70"

17.8

1.48"

37.6

0.99"

25.1

M8 cable connector

(12.5) (0.49")

(19.8) (0.78")

ø8 ø0.31"

(0.25")

(6.4)

8.15

0.32"

0.78"

19.7

(11.55)

(0.45")

Sensor head (Standard)

GT2-A12/GT2-A12K

152.4

6.00"

0.91"

23

0.34" 8.7

0.23"

5.9

2-ø4.3

ø0.17"

ø15

ø0.59"

30

1.18"

12.2

0.48"

ø12 ø0.47" h6

( )

-0.011

( )

(53.3)

(2.10")

0.38"

9.7

(106.5)

(4.19")

(14.3)

(0.56")

45.9

1.80"

108.9

4.29"

115.3

4.54"

0.15"

3.8

17 0.67"

2.4

0.09"

(17.8)

(0.70")

48.6

to

100.6

52.4

to

104.4

1.91" to

3.96"

2.06" to

4.11"

(25.4)

(1.00")

ø5

ø0.20"

12.2

0.48"

0.42" 10.75

0.61" 15.5

0.23" 5.95

28

1.10"

ø9.5 ø0.37"

(12.5) (0.49")

M8 connector

(0.3) (0.01")

20 0.79"

(7.8)

(0.30")

There are no dust boots on the low stress type

GT2-A12L/A12KL

Sensor head (Standard)

GT2-A32

Sensor head (Standard)

GT2-A50

0.04" 1.05

0.06" 1.55

0.12"

ø0.46"

3.05

ø11.6

(58)

(2.28")

66.7

2.63"

95.3

3.75"

0.34" 8.7

0.59" 15.1

1.14"

to

29

to

1.63" 41.5

32.8

to

45.3

1.29"

to

1.78"

(22) (0.87")

3.8 0.15"

0.24" 6

ø8 ø0.31" h5

0.49" 25.1

0.70" 17.8

0.80" 20.35

37.6

1.48"

(12.5) (0.49")

(19.8) (0.78")

ø9.5 ø0.37"

M8 connector

0.91" 23

(0.56") (14.3)

0.34" 8.7

0.23" 5.9

ø0.17"

2 - ø4.3

1.18"

(0.70")

ø15

ø0.59"

30

(17.8)

0.48" 12.2

ø12 ø0.47" h6

0.99" 25.1

0.70" 17.8

0.80" 20.35

(53.3)

(2.10")

88.5

119.5

4.70"

3.48"

90.9

9.7 0.38"

3.58"

27.9

1.10"

0.09"

2.4

17

0.67"

44.3

to

77.8

1.74"

to

3.06"

48.1

to

81.6

1.89"

to

3.21"

3.8 0.15"

(25.4) (1.00")

37.6

1.48"

(12.5) (0.49")

(19.8) (0.78")

ø9.5 ø0.37"

Cable connection

(Straight)

3.4

0.13"

ø0.37" ø9.5

137.5

5.41"

20.35 0.80"

1.00" 25.5

(0.40") (10.1)

0.23" 5.9

0.05" 1.15

32.5

1.28"

16

0.63"

One-touch air supply joint

(for 4 mm 0.16" outside diameter air tube.)

Air exhaust joint

(for 2.5 mm 0.10" inside diameter air tube.)

ø14 ø0.55"

0.88"

0.99"

22.4

25.15

(0.22")

(5.5)

97.35

3.83"

0.22" 12.5

39.8

1.57"

84.85

3.34"

17.7

0.70"

13.1 0.52"

15 0.59"

18 0.71"

8.75

0.34"

ø0.16" ø4

0.25" 6.4

0.32" 8.15

34.5

1.36"

1.46"

37

30

1.18"

19.7

0.78"

(9.6) (0.38")

One-touch air supply joint

(for 4 mm

(11.55)

(0.45")

0.16" outside diameter air tube.)

Air exhaust joint

(for 2.5 mm 0.10" inside diameter air tube.)

ø14 ø0.55"

1.17" 29.75

0.13" 3.4

1.06" 27

15 0.59"

0.49" 12.5

155.2

6.11"

(5.5)

(0.22")

142.7

5.62"

75.65

2.98"

18 0.71"

28.1 1.11"

32.7 1.29"

15 0.59"

18 0.71"

0.01" 0.3

5.6

0.22"

ø0.20" ø5

0.48" 12.2

0.32" 8.15

39

1.54"

1.46"

37

30

1.18"

19.7

0.78"

1.17" 29.75

1.06" 27

(7.8) (0.31")

One-touch air supply joint

(for 4 mm

(11.55)

0.16"

(0.45")

outside diameter air tube.)

Air exhaust joint

(for 2.5 mm 0.10" inside diameter air tube.)

ø14 ø0.55"

15 0.59"

M8 connector

0.91" 23

(0.56") (14.3)

0.34" 8.7

0.23" 5.9

ø0.17"

2 - ø4.3

ø15

ø0.59"

1.18" 30

(0.70") (17.8)

0.48" 12.2

ø12 ø0.47" h6

(53.3)

(2.10")

106.5

4.19"

9.7 0.38"

137.5

5.41"

108.9

4.29"

45.89

1.81" 0.09"

2.4

49.1

to

17

0.67"

100.6

1.93"

to 52.9

3.96" to

104.4

2.08"

to

4.11"

3.8 0.15"

(25.4) (1.00")

0.13" 3.4

0.01" 0.3

178.7

7.04"

0.49" 12.5

(5.5)

(0.22")

191.2

7.53"

93.65

3.69"

5.6

0.22"

ø0.20" ø5

0.48" 12.2

39

1.54"

(7.8) (0.31")

18 0.71"

28.1 1.11"

32.7 1.29"

15 0.59"

18 0.71"

25

26

Dimensions

Unit: mm inch

Sensor head cable (Straight)

GT2-CH2M/CH5M/CH10M/CH20M

(Optional)

A

ø9.5

ø0.37"

27.2

1.07"

7.2

0.28"

C

L

ø11 ø0.43"

2

ø0.19"

ø4.8, 4 x 0.22 mm

2

1

4

A

3

4

3

2

1

B

21.4

0.84"

20.6 0.81"

10.4 0.41"

C

B

C-C

9.4 0.37"

Sensor head cable (L-shaped)

GT2-CHL2M/CHL5M/CHL10M/CHL20M

(Optional)

0.95" 24.2

23

0.91"

L

ø0.43" ø11

C

20.6 0.81"

A

ø7

ø0.28"

ø9

ø9

ø0.35"

ø0.35"

2

1

4

A

3

ø0.19"

ø4.8,

4 x 0.22 mm

2

4

3

2

1

B

21.4

0.84"

10.4 0.41"

C

B

C-C

9.4 0.37"

Sensor head mounting bracket A (Optional)

OP-76874

0.47" 12

ø10 ø0.39" g6

( )

( )

C1.5

C0.06"

Material: TYPE304

Stainless

steel

12 0.47"

R6.5

R0.26"

Mounting hole

ø8 ø0.31"

G6

( ) ( )

6

0.24"

+0.0006"

+0.0002"

16.3

0.64"

ø10 ø0.39"

C0.5 to C1.0

G8

C0.02" to C0.04"

( )

3.5

0.14"

7.8

0.31"

5.5 to 11.3

0.22" to 0.44"

Sensor head mounting bracket C (Optional)

OP-84396

0.47" 12

ø10 ø0.39" g6

( )

( )

C1.5

C0.06"

Material: TYPE304

Stainless

steel

12 0.47"

R6.5

R0.26"

ø8 ø0.31"

G6

( ) ( )

5

0.20"

6

0.24"

16.3

0.64"

7.8

0.31"

Mounting hole

ø10 ø0.39"

C0.5 to C1.0

C0.02" to C0.04"

( )

( )

5.5 to 11.3

0.22" to 0.44"

Sensor head mounting bracket B (Optional)

OP-76875

16.3

0.64"

11

0.43"

10.5

0.41"

6.5

0.26"

(0.01")

(0.2)

32 1.26"

R8

R0.31"

4-C2 C0.08"

12.1

0.48"

0.25" 6.3

ø4.2

ø0.17"

R3.8

R0.15"

15

0.59"

3.5

0.14"

Material: TYPE304

ø8 ø0.31" G6

( )

2

3

A

1

4

3

4

B

1

2

Sheath color

Brown

White

Blue

Black

Model

GT2-CH2M

GT2-CH5M

GT2-CH10M

GT2-CH20M

L

2000 78.74"

5000 196.85"

10000 393.70"

20000 787.40"

2

3

A

1

4

B

1

3

4

2

Sheath color

Brown

White

Blue

Black

Model

GT2-CHL2M

GT2-CHL5M

GT2-CHL10M

GT2-CHL20M

L

2000 78.74"

5000 196.85"

10000 393.70"

20000 787.40"

Dust boot

25.3

1.00"

ø7.6 ø0.30"

For GT2-H12K/

H12/A12K/A12

(Optional)

OP-84332

* The dust boot is factory-attached

to the sensor head

(except for the low stress type).

Material: TYPE304

Stainless steel, NBR

58.2

2.29"

ø11.6 ø0.46"

For GT2-H32/A32

(Optional)

OP-84459

81

3.19"

ø11.6 ø0.46"

For GT2-H50/A50

(Optional)

OP-84460

Sensor head mounting bracket D (Optional)

OP-84327

0.63"

16

0.63"

16

R0.33"

R8.5

ø0.47"

ø12

G6

ø14

ø0.55" g6

( )

( )

C1.5

C0.06"

6 0.24"

7.8 0.31"

16.3

0.64"

5 0.20"

17 0.67"

Material: TYPE303

Stainless

steel

17

0.67"

17

0.67"

Mounting hole

ø14 ø0.55"

( )

( )

C0.02" to C0.04"

C0.5 to C1.0

5.5 to 11.3

0.22" to 0.44"

Unit: mm inch

Contact

Standard

OP-77678

5 0.20"

0.02"

M2.5 × 0.45

3.8

0.15"

SR1.5 0.06"

ø5 ø0.20"

Standard equipment of the generalpurpose sensor head

GT2-H12 (L)/

H32 (L)/H50/

A12 (L)/A32/A50

Material: TYPE304

TYPE440C

Fluorocarbon resin

(Optional)

OP-80228

0.20"

5

9

0.35"

Super-tough

OP-77682

5 0.20"

0.02"

M2.5 × 0.45

ø5 ø0.20"

Flat plate (Optional)

OP-77679

5 0.20"

0.02"

M2.5 × 0.45

Roller (Optional)

OP-77680

ø7.5

ø0.30"

0.14"

3.5

ø9 ø0.35"

0.02"

M2.5 × 0.45

0.37" 9.5

0.02"

M2.5 × 0.45

3.8

0.15"

SR1.5 0.06"

ø5 ø0.20"

Standard equipment of the high-accuracy type sensor head

GT2-H12K (L)/

A12K (L)

Material: TYPE304

Super-tough tungsten alloy

Ceramic (Optional)

OP-81970

0.20"

5

0.02"

M2.5 × 0.45

4.5

0.18"

ø7

ø0.28"

ø6 ø0.24"

0.30" 7.5

Material: TYPE304

Super-tough

Needle (Optional)

OP-77681

0.20"

5

6.2

0.24"

0.02"

M2.5 × 0.45

Material: TYPE304

4.5

0.18"

TYPE440C steel 4.4

4

0.17" 0.16"

9

0.35"

Offset (Optional)

OP-77683

ø6

ø0.24"

8

0.31"

0.20" 5

SR1.5 0.06"

ø5 ø0.20"

3.8

0.15"

SR1.5 0.06"

21

0.83"

20

0.79"

ø9

ø0.35"

ø7.5

ø0.30"

0.02"

M2.5 × 0.45

3.5

0.14"

Material: Fluorocarbon resin (PTFE) Material: TYPE304 Stainless steel,

Ceramic

SR0.8 0.03"

10

0.39"

ø1.6

ø0.06"

C0.2 C0.008"

ø1.2

ø0.05"

ø4 ø0.16"

Material: TYPE304

Super-tough tungsten alloy

Lift lever (Optional)

OP-84397

3.6

0.14"

0.09"

2.3

21.4

0.84"

19.2

0.76"

8.3

0.33"

15.3

0.60"

5.2

0.20"

4.7

0.19"

Material: TYPE304

0.8

0.03"

Spacer (Optional)

OP-77684

5.5

0.22"

0.08"

12.2 2

0.48"

M2.5 × 0.45 0.02"

3.6

0.14"

M2.5 × 0.45 0.02"

Effective screw depth:

6.5 mm

ø4 ø0.16"

Material: TYPE304

Stainless steel

0.26"

Material: TYPE304

Super-tough tungsten alloy

Amplifier unit

DIN-rail mount type

GT2-71N/71P/71MCN/71MCP/71CN/71CP

*

24

0.94" 14.6

0.57"

8.9

0.35"

GT2-72N/72P/72CN/72CP

24

0.94"

*

14.6

0.57"

8.9

0.35"

0.12"

3

135° max.

0.12"

3

41.8

1.65"

36.9

1.45"

12.4

0.49"

17.4

0.69"

(Maximum when cover is opened)

82.9 3.26"

41.8

1.65"

36.9

1.45"

12.4

0.49"

17.4

0.69"

15 0.59" min.

20 21.1

0.79" 0.83"

35.4

1.39"

75.8

2.98" 15 0.59" min.

(Maximum when cover is opened) 132.6 5.22"

15 0.59" min.

20 21.1

0.79" 0.83"

35.4

75.8

1.39"

2.98" 15 0.59" min.

* Cable specifications

GT2-71N/71P: ø4.7 ø0.19" , 12-core x Brown/Blue: 0.20 mm 2 , Black/White/Gray/Orange/Green/Pink/Purple/Yellow/Red/Pink purple: 0.15 mm 2 , Cable length: 2 m 6.6'

GT2-72N/72P: ø4.7 ø0.19" , 10-core x Black/White/Gray/Orange/Green/Pink/Purple/Yellow/Red/Pink purple: 0.15 mm

2

, Cable length: 2 m 6.6'

GT2-71MCN/71MCP/71CN/71CP/72CN/72CP

Connector

(connector type/analog output type amplifier unit)

46 1.81"

ø15 ø0.59" ø0.59" ø15

GT2-CA2M/CA10M

Connection cable

44 1.73"

Cable length: 0.3 m, ø4.7

1.18', ø0.19"

*

* Cable specifications

Outer diameter: ø4.7 mm ø0.19" , Cable length: 2 m 6.6' (GT2-CA2M), 10 m 32.8' (GT2-CA10M),

12-core x Brown/Blue: 0.20 mm 2 , Black/White/Gray/Orange/Green/Pink/Purple/Yellow/Red/

Pink purple: 0.15 mm 2

27

28

Dimensions

Unit: mm inch

Amplifier unit

Pulse output

GT2-71D

0.94" 24

8.9

0.35"

*

14.6 0.57"

0.12"

3

135° max.

41.8

1.65"

36.9

1.45"

0.49"

12.4

15 0.59" min.

20

0.79"

17.4 0.69"

21.1

0.83"

35.4

1.39"

75.8 2.98"

(Maximum when cover is opened) 132.6 5.22"

15 0.59" min.

* Cable specifications

Outer diameter: ø4.7 mm ø0.19" , Cable length: 2 m 6.6' ,

9-core x Brown/Blue/Purple/Pink/Orange/Green/Gray/White/Black: 0.15 mm 2

(Maximum when cover is opened)

82.9 3.26"

Mounting bracket for

DIN-rail mount type amplifier (Optional)

OP-76877

5

0.20"

15

0.59"

2-(4.4 × 3.4)

(0.17" × 0.13")

2-ø3.4

ø0.13"

24

0.94"

22

0.87"

15

0.59"

28.6

1.13"

35 1.38"

Material: SPCC steel

End unit (Optional) (2 pcs.)

OP-26751

0.24"

6

DIN-rail mount

(22.6)

(0.89")

20.8

0.82"

9.2

0.36"

35.4

1.39"

53.8

2.12"

Material: Polycarbonate, Stainless steel

When several units are connected

L

6

0.24"

53.8

2.12"

10.1

0.40"

6

0.24"

53.8

2.12"

10.1

0.40"

Number of units

1

5

6

7

8

9

2

3

4

10

11

12

13

14

15

L

24 0.94"

48 1.89"

72 2.83"

96 3.78"

120 4.72"

144 5.67"

168 6.61"

192 7.56"

216 8.50"

240 9.45"

264 10.39"

288 11.34"

312 12.28"

336 13.23"

360 14.17"

Amplifier unit

Panel mount type

GT2-75N/75P/76N/76P

44.7

1.76"

13.9

0.55"

13.4

0.53"

Panel mounting bracket

(Accessory)

OP-84394

0.06" 1.5

66 2.60"

2.05"

0.28"

7

52

2.3

0.09"

23.9

0.94"

* Cable specifications (common to all amplifier units)

GT2-75N/75P: ø4.7 ø0.19" , 12-core x Brown/Blue: 0.20 mm 2 , Black/White/Gray/

Orange/Green/Pink/Purple/Yellow/Red/Pink purple: 0.15 mm 2 ,

Cable length: 2 m 6.6'

GT2-76N/76P: ø4.7 ø0.19" , 10-core x Black/White/Gray/Orange/Green/Pink/

Purple/Yellow/Red/Pink purple: 0.15 mm 2 , Cable length: 2 m 6.6'

0.78"

19.8

*

12.2

20.9

0.48"

0.82"

8.5

0.33"

4.1

0.16"

38.8

1.53"

X

49 1.93"

24

0.94"

Protective front cover

23.8

0.94"

21

0.84"

+0.4

-0

+0.02"

-0

69 2.72"

11.7

0.46"

Material: (Mounting bracket) Polyacetal,

(Protective front cover) Polycarbonate

Panel cutout

45 1.77"

45 1.77"

X = 24 x (A-1) + 21

0.94" 0.84"

When A amplifier units are closely mounted

69.5 2.74" min.

Panel mounting bracket

(73) (2.87")

11.9

0.47"

Panel thickness

1 to 6

0.04" to 0.24"

Amplifier unit

Large display

GT2-100N/100P

When the supplied mounting bracket is attached

159.5 6.28"

0.04" to 0.24"

Panel thickness: 1 to 6

79.8

3.14"

49.3

1.94"

75.8

2.98"

82.7

3.26"

1.18"

29.9

60 2.36"

0.43" 11

0.48" 12.1

82 3.23"

85.2 3.35"

1.57" 40

1.10" 28

Screw hole for mounting OP84331

Nominal diameter: 3 0.12" , Tapping depth: 5 0.20" max.

138.8 5.46"

161.8 6.37" (Outer dimension of the supplied mounting bracket)

97.2

3.83"

(119.6)

(4.71")

(139.4)

(5.49")

Panel cutout

139.5 5.49"

+1 +0.04"

-0 -0

0.05" 1.2

76 2.99"

+1 +0.04"

-0 -0

When the optional mounting bracket (OP-84331) is used

Unit: mm inch

GT2-E3N/E3P Expansion board

133 5.24"

1.6

0.06"

15.1

0.59"

1.34" 34

1.57" 40

Nominal diameter: 3 0.12" , 4-ø5 ø0.20" fastened with four tapping screws (supplied)

5.6 0.22"

150 5.91"

5.6

0.22"

Communication unit

BCD output type

DL-RB1A

DIN-rail mount

22.5

0.89"

84.4

3.32"

4.6

0.18"

ø0.14"

4-ø3.5

t=1.6

6.6

0.06"

0.26"

40

1.57"

1.10" 28

40.5

1.59"

60 2.36"

150 5.91"

160 6.30"

When the mounting bracket is attached (Optional)

OP-60412

34-pin MIL connector

53.4

2.10"

(57.8)

(2.28")

37.1

1.46"

21.1

0.83"

70

35.4

1.39"

2.76"

53.4

2.10"

60.9

2.40"

37.1

1.46"

31.4

1.24"

70

15

0.59"

2.76"

2-ø3.4

ø0.13"

2-(4.4 × 3.4)

(0.17" × 0.13")

22.5

0.89"

Material: SPCC

steel

15

0.59"

28.5

1.12"

35.5

1.40"

When the mounting bracket is attached (Optional)

OP-60412

Communication unit

RS-232C communication type

DL-RS1A

DIN-rail mount

22.5

0.89"

(48.2)

(1.90")

37.2

43.8

1.72"

1.46"

21.1

0.83"

70

35.4

1.39"

2.76"

51.3

2.02"

37.2

1.46"

43.8

1.72"

Material: SPCC

steel

31.4

1.24"

70

15

0.59"

2.76"

2-ø3.4

ø0.13"

2-(4.4 × 3.4)

(0.17" × 0.13")

22.5

0.89"

15

0.59"

28.5

1.12"

35.5

1.40"

CAD DATA Download Service www.keyence.com/cad

29

Product confi guration

Sensor head cable

→P.15/step 2

Display unit (amplifi er unit)

→P.16/step 4-5

Sensor head

→P.13/step 1

Mounting bracket

→P.15/step 3

Contact

→P.18/step 6

Communication unit

→P.18/step 7-8

30

Reference

Calculation functions using expansion units

The GT2-70 Series* enables calculations such as the maximum and the minimum values of several detection points when several expansion units

(up to 14 units) are connected to a main unit. Outline of each calculation function is as follows:

No.

C1

C2

C3

C4

C5

C6

C7

Calculation function

Description

Number of connectable expansion units

Calculation mode

Dedicated

Calculation mode

Maximum value

Minimum value

Degree of fl atness

Average

Reference difference

Twist

Displays the minimum value of the values of the main unit and expansion unit(s).

Displays the difference between the maximum and the minimum value of the main unit and expansion unit(s).

Displays the resulting calculation of the average of the main unit and expansion unit(s).

Displays the difference obtained by subtracting the display value of the main unit from each of the expansion unit(s).

Displays the degree of twist calculated from the values of four sensor heads.

Warpage

Displays the maximum value of the values of the main unit and expansion unit(s).

Displays the degree of warpage calculated from the values three sensor heads.

1 to 14 units

Only 3 units

Only 2 units

2 to 14 units

Not selectable

Only 4 units

Only 3 units

C8 Thickness

Displays the thickness calculated by two sensor heads "sandwiching" a target between them.

* Except GT2-71D.

Only 1 unit Only 2 units

About “Calculation mode”

When “Calculation mode” is selected for “A1: Calculation mode”, the main unit outputs a calculation result, and output of the expansion unit is OFF.

(Except for a case where “C5: Difference from reference display” is selected)

NOTE - The calculation mode can be selected for the main unit to which one or more expansion units are connected.

About “Calculation dedicated mode”

When “Calculation dedicated mode” is selected for “A1: Calculation mode”, only the main unit outputs a calculation result, and the expansion unit outputs a judgment result based on each setting.

NOTE

- The calculation dedicated mode can be selected for the main unit to which two or more expansion units are connected.

- When the calculation dedicated mode is selected, “C5: Reference

Difference” cannot be selected for calculation method.

- When the calculation dedicated mode is selected, a sensor head cannot be connected to the main unit. Attach the supplied “sensor head connector seal” to the sensor head connector of the main unit.

Bank function

With the Bank function, up to four patterns of HH, HIGH, LOW and LL set values, preset values can be registered in advance.

Since the registered settings (four patterns) can be easily changed, this function is useful for detection of several targets.

About accuracy of the high-accuracy type

When the high-accuracy type measures a distance between two arbitrary points in the measuring range at an ambient temperature (20°C

(68°F)), the deviation from the actual value is 1 µm 0.04 Mil or less. For example, when a measurement result is 11 mm 0.43" , the actual value is in a range of 10.999 to 11.001 mm 0.4330" to 0.4331" . For several measurements, variations in the measured value are 1 µm 0.04 Mil or less.

5-output function

(Except GT2-71MCN/71MCP)

This function enables differentiation of fi ve output statuses (HH,

HIGH, GO, LOW and LL). HH and LL outputs can also be used for jam detection.

General purpose digital contact sensor

GT Series

Features

[Easy setup]

Head installation is as easy as drilling a hole.

[Easy programming]

Auto-tuning function enables simple, sensor-like tuning.

[Smart operation]

Self-diagnostic function outputs an alarm when the sensor head cable becomes damaged

Setup

Amplifi er units

Appearance Model

GT-71A

GT-72A

GT-71AP

GT-72AP

GT-75A

GT-76A

GT-75AP

GT-76AP

Standard model

Shortest in its class

Total length 90 mm 3.54"

Smallest length among the 10-mm

0.39" stroke type sensor heads

DIN rail mount

Panel mount

Type

Main unit

Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Output type

NPN

PNP

NPN

PNP

BCD output / RS-232C communication unit

Model Appearance Type

DL-RB1A

BCD

DL-RS1A

RS-232C

Low Stress model Air Push model

Using low force spring

10-mm 0.39" stroke sensor head

GT-H10

22-mm 0.87" stroke sensor head

GT-H22

10-mm 0.39" stroke, low stress sensor head

GT-H10L

22-mm 0.87" stroke, low stress sensor head

GT-H22L

10-mm 0.39" stroke air push type sensor head

GT-A10

22-mm 0.87" stroke air push type sensor head

GT-A22

31

http://www.measurecentral.com

NEW

Web Site Dedicated to

Measurement Solutions!

❙ TECHNICAL INFORMATION

❙ APPLICATION SEARCH FUNCTION

❙ FREE SOFTWARE DOWNLOAD

Laser Displacement (1D) LK-G Series

Measuring the thickness of a silicon wafer

Measuring the thickness of a glass plate

Sampling rate of 50 kHz

Linearity of ± 0.02% of F.S.

Repeatability down to 0.01 µm 0.0004 Mil

Thickness measurement/loop control of a rubber sheet

Measuring the displacement of a rotating shaft

CALL

TOLL

FREE

T O C O N T A C T Y O U R L O C A L O F F I C E

1-888-KEYENCE

1 - 8 8 8 - 5 3 9 - 3 6 2 3

www.

keyence .com

SAFETY INFORMATION

Please read the instruction manual carefully in order to safely operate any KEYENCE product.

KEYENCE CORPORATION OF AMERICA

Corporate Office 669 River Drive, Suite 403, Elmwood Park, NJ 07407 PHONE: 201-930-0100 FAX: 201-930-0099 E-mail: [email protected]

Sales & Marketing Head Office 1100 North Arlington Heights Road, Suite 350, Itasca, IL 60143 PHONE: 888-539-3623 FAX: 630-285-1316

Regional offices

AL

Birmingham

CA

CA

N.California

Los Angeles

CO

FL

GA

IL

Denver

Tampa

Atlanta

Chicago

IN

KS

KY

MA

Indianapolis

Kansas City

Louisville

Boston

MI

MI

MN

MO

Detroit

Grand Rapids

Minneapolis

St. Louis

NJ

NY

NC

NC

Elmwood Park

Rochester

Charlotte

Raleigh

OH

OH

OR

PA

Cincinnati

Cleveland

Portland

Philadelphia

SC

TN

TN

TX

Greenville

Knoxville

Nashville

Austin

TX

VA

WA

Dallas

Richmond

Seattle

KEYENCE CANADA INC.

Head Office PHONE: 905-696-9970 FAX: 905-696-8340 E-mail: [email protected]

Montreal PHONE: 514-694-4740 FAX: 514-694-3206

KEYENCE GLOBAL HEADQUARTERS

1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: +81-6-6379-2211

KEYENCE MEXICO S.A. DE C.V.

PHONE: +52-81-8220-7900 FAX: +52-81-8220-9097

E-mail: [email protected]

KA1-1090

The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice.

Copyright (c) 2009 KEYENCE CORPORATION. All rights reserved.

GT2-KA-C2-E 1011-6 611176 Printed in Japan