The SHARP AR-235/275 AR-FX4 is a digital copier with a printer option and a FAX expansion kit. It can scan and copy documents, as well as send and receive faxes. The expansion kit allows the user to add more memory to the machine to increase the number of pages that can be stored for later transmission. The device includes a number of features that make it a convenient and versatile tool, including automatic document feeders, a variety of resolution settings, and a variety of transmission modes.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

SHARP AR-235/275 AR-FX4 Service Manual | Manualzz

SERVICE MANUAL

CODE: 00ZARFX4//A1E

DIGITAL LASER COPIER/

PRINTER OPTION

FAX EXPANSION KIT

(For U.S.A./Canada)

MODEL

AR-FX4

EXPANSION MEMORY

2MB: AR-MM5

4MB: AR-MM6

8MB: AR-MM7

CONTENTS

[1] OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

[2] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

[3] INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

[4] ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

[5] SIMULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

[6] SOFT SWITCH DESCRIPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1

[7] KEY OPERATOR PROGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1

[8] FLASH ROM VERSION UP PROCEDURE . . . . . . . . . . . . . . . . . . 8-1

[9] TROUBLE CODE LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1

[10] ELECTRICAL SECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1

Parts marked with “ ” are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.

SHARP CORPORATION

This document has been published to be used for after sales service only.

The contents are subject to change without notice.

CONTENTS

[1] OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

[2] SPECIFICATIONS

1. Communication system . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

2. Scanning system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

3. Image process system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

4. Print system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

5. Transmission function system. . . . . . . . . . . . . . . . . . . . . . . 1-2

6. Reception function system . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

7. Registration system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

8. Telephone function system . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

9. Memory system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

10. Additional information function for transmission . . . . . . . . . 1-4

11. Additional print function when receiving . . . . . . . . . . . . . . . 1-4

12. Recording table system . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

13. Others . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

[3] INSTALLATION PROCEDURE

1. Install of expansion kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

A. Parts included. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

B. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

2. Mounting of additional memory (AR-MM5, MM6, MM7) . . . 3-3

[4] ADJUSTMENTS

1. Density section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

A. FAX mode density adjustment (Overall mode) (<FAX mode> SIM 46-12) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

B. FAX mode density adjustment (Individual mode) (<FAX mode> SIM 46-13 – 16) . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

2. Communication section . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

A. Dial test (<FAX mode> SIM 66-13) . . . . . . . . . . . . . . . . 4-2

[5] SIMULATION

1. Entering the simulation mode/cancel of simulation mode . 5-1

2. Simulation code list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

3. Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

[6] SOFT SWITCH DESCRIPTIONS

1. Quick reference of FAX soft SW setup change . . . . . . . . . 6-1

2. Soft switch list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2

3. Soft switch descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19

[7] KEY OPERATOR PROGRAM

1. List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1

2. Operating procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2

A. Common procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2

B. List output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3

[8] FLASH ROM VERSION UP PROCEDURE

1. Program download procedure (Main body program, FAX program) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1

2. Others (Error list) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2

[9] TROUBLE CODE LIST

1. Machine trouble codes . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1

2. Communication result code . . . . . . . . . . . . . . . . . . . . . . . . 9-2

A. Composition of communication report code . . . . . . . . . 9-2

3. List of buzzer sounds in case of FAX abnormality . . . . . . . 9-4

[10] ELECTRICAL SECTION

1. Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1

A. Main block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1

B. TEL/LIU PWB block diagram. . . . . . . . . . . . . . . . . . . . 10-2

2. Circuit diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3

A. FAX MAIN PWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3

B. TEL/LIU PWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-13

[1] OUTLINE

This unit is a fax expansion kit which provides facsimile functions by attaching to the digital machine AR-235/275 series.

To expand facsimile functions, use of SPF/RSPF is recommendable.

By attaching a job separator/finisher, copy output and fax output can be separately discharged to different trays.

RSPF (AR-RP3)

The fax board of the fax expansion kit is provided with 2MB flash memory (standard). An expansion memory of one of 2MB/4MB/8MB can be added. (2MB expansion memory for fax, AR-MM5; 4MB expansion memory for fax, AR-MM6; 8MB expansion memory for fax, AR-MM7)

SPF (AR-SP4)

Job separator

(AR-TR3)

FAX expansion kit

(AR-FX4)

2MB 4MB 8MB

AR-MM5 AR-MM6 AR-MM7

Expansion memory (One of them is attached to.)

Finisher

(AR-FN5)

[2] SPECIFICATIONS

1. Communication system

(1) Electronic transmission system

Transmission time About 3 sec (Super G3/33660bps)

About 6sec (G3 ECM/14400bps)

Compression system MH, MR, MMR, JBIG

Modem speed 33600bps

2400 auto fall back

Mutual communication

Super G3/G3

Employed line Public Switched Telephone Network

(PSTN), Private Branch Exchange (PBX)

One line (no additional line allowed) Number of employed lines

ECM YES

2. Scanning system

(1) Document size

Max. document width

Unscanable area

297mm (11.7")

Auto detection size

OC

SPF/

RSPF

Lead edge 5mm or less, rear edge 5mm or less left & right edges 6mm or less

AB series A3/B4/A4/A4R/A5

Inch series 11 x 17/8.5 x 14/8.5 x 11/

8.5 x 11R/5.5 x 8.5

AB series A3/B4/A4/A4R/A5

Inch series 11 x 17/8.5 x 14/8.5 x 11/

8.5 x 11R/5.5 x 8.5

Document size specified

AB series

Inch series 11 x 17/8.5 x 14/8.5 x 11/

8.5 x 11R/5.5 x 8.5/A4/A4R

AB series

+ foolscap

A3/B4/A4/A4R/A5/8.5 x 11/

8.5 x 11R/8.5 x 13

YES

A3/B4/A4/A4R/A5/8.5 x 11/

8.5 x 11R

Duplex document specified

Long document Max. 1000mm,.depending on the document width and resolution

Differs in single/duplex.

(2) Transmission mode document load quantity scan cycle (SPF/RSPF capacity)

SPF/OC transmission select

Continuous auto paper feed

Document load capacity

NO (Selection inhibited during scanning of a document)

YES

30 sheets

(3) Half-tone reproduction density adjustment

Document scan cycle About 40 pages/min (Normal, A4R memory transmission, guaranteed scan pages = 30 pages)

Document scan speed

About 1.5sec/page (Normal, A4R memory transmission)

Half-tone (Photo mode)

Density selection

Equivalent to 256 gradations (Combination of fine/super fine/ultra fine is possible.)

Auto/manual in 5 steps

AR-FX4 OUTLINE/SPECIFICATIONS - 1

3. Image process system

(1) Image selection

Normal

Fine

Super fine

Ultra fine

8dot/mm x 3.85line/mm

8dot/mm x 7.7line/mm

8dot/mm x 15.4line/mm

16dot/mm x 15.4line/mm: ITU-T conforming

(reception impossible without additional memory. Receives in super fine mode.)

(2) Print resolution

600dpi (with resolution correction)

4. Print system

(1) Recording size

Max. record width 293mm (11.5")

Recording paper YES (All sizes except for multi paper feed.

→ size detection Recognition of the set size. The tray has no function to detect the actual paper size.)

Recording paper size

AB series

Inch series

A3/B4/A4/A4R/A5/8.5 x 11/8.5 x 11R

11 x 17/8.5 x 14/8.5 x 11/8.5 x 11R/

5.5 x 8.5/A4/A4R

(2) Recording paper

Cassette capacity Machine: 500 x 1 or 500 x 2

Option: 500 x 1 or 500 x 2

YES Recording paper empty detection

Paper feed All installed trays except for multi-manual tray.

5. Transmission function system

(1) Simplified dialing function

Rapid key dialing 50 items

Speed dialing 300 items

Group dialing

Telephone directory transmission

Chain dialing

Redialing

Program

Mode recall

50 items (including rapid key dialing)

Any of other parties registered to speed dialing, rapid key dialing, and group dialing can be searched for using the first 10 letters.

YES

The preceding number is saved, and is not cleared even with CLEAR ALL key.

9 items

NO

(2) F-code communication

Sub address

Password

(3) Time specification

YES (Max. 20 digits)

YES (Max. 20 digits)

Time specification:

Transmission/polling

(4) Recall mode

Time is specified in transmission/polling.

Auto recall mode when other party is busy.

Interval

Number of times

1min to 15min, default 3min

0 to 14 times / 0: No resend

Default 2 times

Auto recall mode when in a communication error

Interval 1min to 15min / 0: Resend immediately after disconnection of the line

Default 1min

1 time only / 0: No resend

Default 1 times

Number of times

Number of transmissions simultaneously.

Send page After the error page

Max. 50 items counted in recall mode

(5) Automatic reduction transmission

Message is reduced according to the receiver’s machine.

YES (ON/OFF by key operator program)

(6) Memory transmission/direct transmission

Memory transmission

Memory transmission

Number of transmission reservation to be set

Process in memory full

Quick online transmission

Direct transmission

Default setup

YES

Max. 50 items

Transmission cancel or only scanned data transmission

YES (Enable/Disable setup by key operator program)

YES (30 pages from SPF, only 1 page from OC)

Set by key operator program

(7) Broadcast function

Broadcast transmission

Group dialing

Relay broadcast transmission

Number of destinations

200 destinations (When group dialing is used, the number of other parties registered to group dialing is added.)

Broadcast key, group key Transmission method

Usable dial

Instructing station

10-key entry, rapid key dialing, speed dialing.

However, those of which sub address is registered cannot be used.

Transmitted by group dialing registered to rapid key dialing

Only from the machine having Sharp relay broadcast instructing transmission function

Relay station Only from the machine having Sharp relay broadcast transmission function

Multiple relay NO

10 groups Number of relay groups

Number of receiving stations that may be specified per group

120 items in rapid key dialing, 240 items in speed dialing

(8) Confidential function

Confidential transmission

Other station Only Sharp machine having confidential function

(9) Scan specification

Page division

Page coupling

(10) Priority function

YES (Allowed only from OC)

NO

Transmission reservation interrupt

Broadcast interrupt

YES (by direct transmission)

YES (by direct transmission)

(11) Serial transmission function

Serial transmission NO

(12) Rotation transmission

Paper size AB series

Inch series

A4

A4R, 8.5 x 11

8.5 x 11R

8.5 x 11

8.5 x 11R, A4

A4R,

(13) Book document transmission

Transmission method

Page division

By OC mode

YES

AR-FX4 OUTLINE/SPECIFICATIONS - 2

(14) Finish stamp

NO

(15) Bulletin board, polling transmission functions

Bulletin board Bulletin board

Protection function

Check by other party’s number

Check by matching of system number (user’s own machine), ID number (other party’s machine) (between Sharp machines only)

YES

YES

YES

6. Reception function system

(1) Reception mode

Default setup

Automatic reception

Manual reception

Automatic reception (Reception state switchable)

YES Automatic reception setup

Number of calls 0 to 9 times (Factory setup 2 times, variable)

Automatic switching of

Telephone/Fax

NO

Non-call reception Allowed by setting the number of calls to 0.

YES Manual reception setup

Setup for switching to automatic reception

NO

NO Number of calls to switch to automatic reception in manual reception mode

Dial-in

Answering machine connection

Answering connection

Reception mode time switch

NO

NO

NO

(2) Zoom reception

Reduction Reduction to regular size

Reduction between regular sizes

Enlargement

YES (ON/OFF by key operator program)

YES (by print condition setup of key operator program)

NO

(3) Memory reception function

Proxy reception

Compulsory memory reception

Only when output is disabled.

NO

(4) Received data override output

YES

(5) Transfer

Transfer destination registration YES (Registered by key operator program)

Transfer procedure YES (Operated with function menu)

(6) Specified number reception

Reception of only specified numbers allowed

Reception of specified numbers inhibited

(7) Confidential function

Confidential reception

NO

YES

Sender Sharp machine having confidential function only

Confidential box Registered up to 10 boxes

36 letters Confidential box name

Confidential ID code

May be set per confidential box

AR-FX4 OUTLINE/SPECIFICATIONS - 3

(8) Rotation reception

Paper is outputted by rotating 90 degrees to the set direction of paper in cassette

(9) Division reception

Division size When no paper for reception of long document

Division reception setup YES (by print condition setup of key operator program)

(10) Duplex reception

NO

(11) 2 in 1 reception

NO

(12) Polling (send request)

Polling

Resolution at send request

YES

Variable by soft SW.

Default: fine

(13) Turn around transmission

NO

7. Registration system

(1) Number registration

Speed dialing

Rapid key dialing

Group dialing

Number of items

Number of digits of other party’s number

Registered name

Searched letters

User tag classification

International communication mode setup

Transmission method

Number of items

Number of digits of other party’s number

Registered name

Searched letters

User tag classification

International communication mode setup

Transmission method

Registered key

Max. number of registration per group dialing

Registerable number

300 items

40 digits

36 letters

Up to 10 letters

NO

YES

Speed dialing key + (000 to 299) +

Start key

50 items

40 digits

36 letters

Up to half-size 10 letters

NO

YES

Rapid dialing key (01 – 50)

Rapid dialing key

100 items (The total number of registration is 150 items.)

Registered name

Searched letters

User tag classification

Transmission method

Numbers registered to speed dialing, rapid dialing, and numbers entered with 10-key

36 letters

Up to 10 letters

NO

Rapid dialing key

Program Number of items 9 items

Registerable item All items that can be set in transmission, except for time setup

Registered name

Call method

36 letters

By pressing program key

Change in setup after calling

YES

(2) Sender registration

Sender’s name 36 letters, registered with key operator program

Sender’s number 20 digits, registered with key operator program

(3) Polling (send request), bulletin board (remote transmission) allow number registration)

Send request allow number

System number

ID number

Registration of other party to which send request is made

System number registration

ID number registration

10 digits, 20 digits, registered by key operator program

Up to 1 number, registered in key operator program

Up to 10 items in 4 digits.

Registered by key operator program.

(4) Letter input

Input method

Letters allowed for input

Key entry

Half-size characters

(5) Registered data write

YES

Alphabet, Numerical figures,

Special characters, Codes

YES (Service tool. Dial registration can be made with PC.)

(6) Date/time adjustment

Registered by key operator program.

(7) Backup

Backup of registration in power failure

SRAM used, by built-in battery

8. Telephone function system

Handset

On-hook function

Reserve

Pause

NO

YES

NO

YES (1 to 15sec: Default 2sec, set by key operator program)

Telephone transmission in power failure

Sound volume adjustment

Call sound volume

Line monitor sound

No (However, external telephone transmission is allowed.)

YES (Set by key operator program to

Large/Medium/Small/No sound.)

YES (Set by key operator program to

Large/Medium/Small/No sound.)

On-hook sound YES (Set by key operator program to

Large/Medium/Small.)

Scan end sound

Communication end sound

Tone pulse switch

YES (Set by soft switch to Large/

Medium/Small/No sound.)

YES (Set by soft switch to Large/

Medium/Small/No sound.)

PULSE/TONE selection with key operator program.

YES External telephone connection

Remote reception switch

YES (Switch number is in 1 digit +

5

∗∗

∗∗

)

9. Memory system

Memory capacity Standard

Option

Memory content

(transmission reservation) confirmation

LCD display

Printout

2MB

Up to 8MB (+2MB/+4MB/+8MB)

YES

YES

Memory use status

Document data memory backup in power failure

YES (% display)

YES (Flash memory)

10. Additional information function for transmission

Page counter

Date printing

Cover paper function

Transmission message

Sender print function

Date/ display sequential switch

Cover paper item

Date

Receiver’s name

Receiver’s number

Sender’s name

Sender’s number

Display of number of documents transmitted

Transmission message

Print paper size

Regular message

User message

Sender’s number

Sender’s name

YES

YES (Year/month/day, Year in 4 digits)

NO

YES

YES

YES

YES

YES

YES

YES

A4 (AB series)

8.5 x 11 (Inch series)

CONFIDENTIAL/PLS.

DISTRIBUTE/URGENT/

PLS.

CALL BACK/IMPORTANT

NO

20 digits, registered with key operator program

36 letters

11. Additional print function when receiving

Index print YES (Set by key operator program)

AR-FX4 OUTLINE/SPECIFICATIONS - 4

12. Recording table system

(1) Communication record function

Communication record table size AB series A4 (Not output when paper greater than

A4 is not set.)

Communication record memory capacity

Communication record table

Number of items

Inch series

Letter (not output if size setting is not

Letter or larger)

50 items in total of transmission and reception

Max. 50 items for each of transmission and reception

(Total of transmission and reception is up to 50 items.)

Record table is outputted separately. If registration exceeds 50, the oldest one is deleted.

YES (2 times per day)

Time-specified communication table

Confidential reception check table

Time-specified output

Output when recording memory full

Output of individual department

Soft SW provided

YES (Communication time of each department is outputted as department management record table.)

Common with transmission record table

YES

(2) Communication result report function

Communication result table

(transmission)

(3) Report function

YES (Select Always print/in failure of transmission/no print. With key operator program)

Broadcast communication report

Communication result table

(reception)

Communication result table

(confidential reception)

Document content print in transmission error

YES (Select Always print/in failure of transmission/no print. With key operator program)

YES (Select Always print/in failure of transmission/no print. With key operator program)

YES (Select Always print no print. With key operator program)

YES (Some part of the first page is printed:

ON/OFF setup by key operator program.

Confidential transmission data are never printed.)

(4) Other report list

Rapid key dialing table

Telephone number table

Transmission message list

YES (Rapid key table)

Speed dialing table YES (Speed dialing table)

Group table YES (Group number table

YES (Table of searched letters in rapid key dialing, speed dialing, and group dialing in alphabetical order)

NO

YES

YES

ID/Senders list

Confidential ID table

Soft switch list

Memory image deletion table

YES

NO

13. Others

CSI transmission function

Department management

CSI transmission

Limitation on users in each department

Number of departments registered

Operation panel display

Automatic booting mode

Charge management function for each department

LCD

AR-FX4 OUTLINE/SPECIFICATIONS - 5

YES

YES

20 items

NO

19 letters x 5 lines

NO

[3] INSTALLATION PROCEDURE

1. Install of expansion kit

A. Parts included

2) Attach the fax key unit.

Connect the flat cable to the fax key unit, attach the fax key unit to the operation panel, and use the screw to fix it.

Close the front cover of the copier.

Fax key unit

Screw

Fax key unit: Fax PWB TEL/LIU PWB

Speaker unit: M3 golden screws:

2 pcs.

M3 screws with washer: 6 pcs.

Front cover

3) Remove the shielding plate and the left rear cabinet.

Remove the 5 fixing screws on the shilding plate and take off the shilding plate with inserting the flatblade screwdriver, etc.

Next, remove the 5 fixing screws on the left rear cabinet, and slide it backward to remove.

PWB spacers: 2 pcs.

Fax connector cover:

1 pcs.

Line cable: 1 pcs.

Supplied label:

1 sheet

Writing label: 1 sheet Installation manual:

1 sheet

(2)

(1)

Screws

Operation manuals:

2 pcs.

B. Installation

Turn off the main switch of the copier and then remove the power plug of the copier from the outlet.

1) Remove the fax dummy cover.

Open the front cover of the copier, remove the screw that fixes the fax dummy cover, and remove the fax dummy cover.

Fax dummy cover

Shielding plate

Left rear cabinet

Screws

4) Work the left rear cabinet.

Cut and remove the cut-out portion from the left rear cabinet using a tool such as nippers.

Be careful about the direction of the tool so that the cut surface is flat.

Cut-out portion

Screw

Front cover

AR-FX4 INSTALLATION PROCEDURE - 1

5) Attach the speaker.

Attach the speaker to the left rear cabinet using supplied two golden screws (M3).

M3 golden screws

8) Reattach the left rear cabinet.

1. Pass the speaker harness through the hole of the frame of the fax expansion PWB and connect it to the connector of the fax

PWB.

2. Fit the pawls of the left rear cabinet to the mounting portions of the main unit. Slide the cabinet toward the front of the main unit to attach it.

3. Fix the left rear cabinet with 2 screws.

4. Attach the supplied fax connector cover.

Speaker harness

Screw

1

3

Left rear cabinet

6) Attach the fax PWB.

Mount the two spacers on the fax PWB.

Next, insert the fax PWB connector into the connector on the expansion PWB, install with 4 M3 screws with washer.

M3 screws with washer

Fax PWB

2

4

3

Fax connector cover

Screw

Pawls

9) Reattach the shielding plate.

Fit the pawls of the shielding plate to the main unit and secure the plate using five screws.

Spacers

M3 screws with washer

7) Attach the TEL/LIU PWB.

Insert the TEL/LIU PWB connector into the fax PWB connector, attach 2 spacers on the TEL/LIU PWB, and attach the TEL/LIU

PWB with 2 M3 screws with washer.

Screws

TEL/LIU PWB

Spacers

M3 screws with washer

Shielding plate

Insert the power plug of the copier to the outlet and turn on the main switch. Then, carry out the following procedure.

10) Date/time setting

Press [SPECIAL FUNCTION] key on the operation panel, select

[KEY OPERATOR PROGRAM]. Input 5-digit Key Operator Code with 10-key, and select [FAX] in Mode Select.

Select [DEFAULT SETTING], [DATE/TIME SETTING], and input month/day/year in this order, and press [OK] to set.

Input hour/minute in this order, and press [OK] to set.

AR-FX4 INSTALLATION PROCEDURE - 2

11) Paste the label on the left rear cabinet of the copier.

Paste the FCC label to the position shown in the illustration.

In order to manifest the compliance with FCC Part 68 and IC CS-03, it is required to provide the machine with the FCC Registration Number (USA),

Ringer Equivalence (USA) and Ringer Equivalence (Canada).

After installing the FAX expansion kit in the machine, please put the registration label, packed with the kit, on the prescribed location.

3

FCC label

2. Mounting of additional memory

(AR-MM5, MM6, MM7)

• When mounting memory, turn off the main unit.

1) Remove the fax connector cover using a flatblade screwdriver or the like.

2) Insert the memory card securely so that the model name is on the rear side.

3) Reattach the fax connector cover.

• Turn on the main unit.

(When turning on the main unit just after expansion, the system check time will become longer due to memory initialization.)

4) Make certain that the memory was expanded by displaying SW list with SIM 66-21.

1)

3)

Fax connector cover

1)

2)

3)

Memory card

AR-FX4 INSTALLATION PROCEDURE - 3

[4] ADJUSTMENTS

Section

1 Density section

2 Communication section

1. Density section

Adjustment items

A FAX mode density adjustment (Overall mode)

B FAX mode density adjustment (Individual mode)

A Dial test

A. FAX mode density adjustment (Overall mode)

(<FAX mode> SIM 46-12)

1) Set the test chart (TPAP-2109SCZZ <CCITT #3 chart>) on the OC table as shown below, and close the OC cover.

Adjustment procedures

<FAX mode> SIM 46-12

<FAX mode> SIM 46-13 – 46-16

<FAX mode> SIM 66-13

B. FAX mode density adjustment (Individual mode)

(<FAX mode> SIM 46-13 – 16)

1) Set the test chart (TPAP-2109SCZZ <CCITT #3 chart>) on the OC table as shown below, and close the OC cover.

Glass holding plate

2) Switch to the FAX mode and execute SIM 46-12.

3) After warming up, shading is performed and the current density level is displayed on the lower two digits of the display section in standard and auto density mode.

4) Enter the set value with the 10-key to adjust the FAX image density.

5) Make a copy, and adjust so that the following adjustment specification is satisfied.

When an adjustment is made in this mode, the exposure level for each communication mode and each density mode are automatically adjusted accordingly.

<Adjustment specifications>

Density mode

Auto

Resolution mode

SIM

Standard FAX mode

46-12

CCITT #3 chart output result

“3” is slightly copied.

Set value

The greater the set value is, the greater the density is, and vice versa.

Set range

0 – 99

Glass holding plate

2) Switch to the FAX mode and execute SIM 46-13 to 46-16 depending on the adjustment mode.

3) After warming up, shading is performed and the current density level is displayed on the lower two digits of the display section.

4) Enter the set value with the 10-key to adjust the FAX image density.

5) Make a copy, and adjust the density with the copy as a reference.

<Adjustment specifications>

Resolution mode

Density changeover

Standard Switched with the density select

Fine key.

Switched with the density select key.

Super fine Switched with the density select key.

Ultra fine Switched with the density select key.

SIM

FAX mode 46-

13

FAX mode 46-

14

FAX mode 46-

15

FAX mode 46-

16

Set value

The greater the set value is, the greater the density is, and vice versa.

Set range

0 – 99

AR-FX4 ADJUSTMENTS - 1

2. Communication section

Note: These items are factory adjusted when shipping according to

FCC standards. Therefore, do not change the setting in the market.

A. Dial test (<FAX mode> SIM 66-13)

(1) Dial pulse transmission test

1) Execute SIM 66-13 in FAX mode.

2) Execute the dial pulse mode according to the instructions on the

LCD display.

SELECT SIGNAL

1:PULSE 2:DTMF

3) Select the dial pulse.

SELECT PULSE

1:10PPS 2:20PPS

4) Set the make time.

INPUT MAKE TIME

(0-15) _

5) Select the dial to be transmitted.

Default: 0123456789

#

(After deleting with the clear key, it can be set to any desired value.)

6) Transmission is started from the line.

SEND yyPPS xxm s

1:YES 2:NO

SENDING yyPPS xxm s

Dial pulse make time

10

PPS

20

PPS

SIM

FAX mode

66-13

Soft

SW

SW 67-

1 – 4

SW 67-

5 – 8

Initial value

40ms

(14)

Set value

SW set value: 0 – 15

Make time: 26 – 41ms

0ms 0 fixed

1ms step

(Binary input)

(2) DTMF signal transmission level adjustment

1) Execute SIM 66-13 in the FAX mode.

2) Execute the DTMF mode according to the instructions on the LCD display.

SELECT SIGNAL

1:PULSE 2:DTMF

3) Select the signal transmission level.

The signal transmission level is classified into two groups: the high group, and the low group.

Transmission can be made with either of default and the soft SW set value.

SELECT HIGH LEVEL

1:DEFAULT 2:SOFT SW.

SELECT LOW LEVEL

1:DEFAULT 2:SOFT SW.

4) The transmission level can be set when the following menu is displayed on the LCD. (et value 1 = 0.5dB change)

INPUT VALUE

(0-15) _

(This value is returned to the original value when the simulation mode is canceled.)

5) Select the dial signal to be transmitted.

Default: 0123456789

#

(After deleting with the clear key, it can be set to any desired value.)

AR-FX4 ADJUSTMENTS - 2

6) Start transmission from the line.

H:xx L:yy

1:YES 2:NO xx: High group soft SW set value yy: Low group soft SW set value

SENDING DTMF

SIM

DTMF transmission level

High group

Low group

(FAX mode) 66-

13

(Test only)

Soft

SW

SW 53-

1 – 4

SW 53-

5 – 8

Initial value

Set value

3.5dB SW set value:

(7) 0 – 15

3.5dB

Transmission

(7) level: 0 – 7.5dB

0.5ms step

(Binary input)

[5] SIMULATION

1. Entering the simulation mode/cancel of simulation mode

Procedure

1 Simulation mode selection

Key operation

#

INTERRUPT

C

INTERRUPT

10-key (Input main code)

START

10-key (Input sub code)

START

2 Main code selection

3 Sub code selection

4

Selection of the mode and item

5 Start simulation operation

6

Returns to the sub code selection.

Simulation mode clear

10-key and

↑ ↓

OK or START

INTERRUPT

CA

• Selection of the main code and the sub code is set with the [START] key.

• There are two or more screens, the adjustment "Current page/Max.

page" is displayed. Press [

] key (previous page) or [

] key to select a screen.

2. Simulation code list

Code

Main Sub

8 13

22

24

26

46

48

50

66

14

15

11

10

1

60

12

13 to

16

8

3

4

1

2

9

10

8

9

6

7

10

11

13

17

21

30

32

34

Function

Used to check and adjust the operation of the developing bias voltage in FAX mode and the control circuit.

Used to check and adjust the operation of the main charger grid voltage (high mode) in FAX mode and the control circuit.

Used to check and adjust the operation of the main charger grid voltage (low mode) in FAX mode and the control circuit.

FAX related counter display

FAX related counter clear

Used to set options. (This simulation is used to make option setting when an option is installed.)

Used to set enable/disable of the FAX mode key when FAX is not installed. (When FAX is installed, the FAX mode is enabled regardless of this setup.)

FAX exposure level adjustment (batch)

FAX exposure level adjustment (individual)

FAX magnification ratio adjustment (read)

FAX magnification ratio adjustment (print)

FAX auto reduction magnification ratio (print).

FAX lead edge adjustment (read)

FAX lead edge adjustment (print)

FAX related soft SW setting

Initial set for the value of the FAX soft SW

FAX PWB memory check

Signal send mode

Printing the confidential password

Image data print

Image data memory clear

300bps signals send

Send test and adjustment of the dial pulse and

DTMF signal.

DTMF signal send

FAX information print

TEL/LIU state change recognition

Receive data check

Communication time measurement display

Code

Main Sub

66

37

38

50

Function

Speaker sound volume adjustment

Time setting/check

The FAST area of SRAM is cleared.

3. Details

8

8-13

Purpose

Function

(Purpose)

Section

Adjustment/Operation test/check

Used to check and adjust the operation of the developing bias voltage in FAX mode and the control circuit.

Image process (Photoconductor/Developping/

Transfer/Cleaning)

Developer/Toner hopper

Operation/procedure

Enter the adjustment value and press the [OK] key, and output operation is performed for 30sec.

(Initial screen) (Executing screen)

Sim8-13 DV BIAS FAX

FAX 426

Sim8-13 DV BIAS FAX

FAX 426

EXEC [200-550] 4260 EXEC [200-550] 426

Setting range 200-550

Default 426

The minimum increment is 2V.

The result of (Set value – 199) / 2 is stored in the EEPROM.

When reading a value from the EEPROM, the value of (EEP value *2)

+ 200 is used as the set value.

Therefore, the set value entered must be an even number. If an odd number is entered the entered odd number + 1 is displayed after pressing [OK] key.

8-14

Purpose

Function

(Purpose)

Section

Adjustment/Operation test/check

Used to check and adjust the operation of the main charger grid voltage (high mode) in FAX mode and the control circuit.

Image process (Photoconductor/Developping/

Transfer/Cleaning)

Photo conductor

Operation/procedure

Enter the adjustment value and press the [OK] key, and output operation is performed for 30sec.

The input value is in the increment of –25V.

(Initial screen) (Executing screen)

Sim8-14 MHV(H) FAX

FAX 5

Sim8-14 MHV(H) FAX

FAX 5

EXEC [ 1- 8] 5

Setting range 1-8

Default 5

EXEC [ 1- 8] 5

AR-FX4 SIMULATION - 1

NO.

Set value

1 480

2 505

Grid High Grid Low

–480V –350V

–505V –375V

3

4

530

555

5 580

6 605

7 630

–530V

–555V

–580V

–605V

–630V

8 655 –655V

–400V

–425V

–450V

–475V

–500V

–525V

*1. The negative value of the set value corresponds to the grid high output voltage.

*2. The set values can be selected from the above 8 patterns only.

*3. The selected pattern determines the grid high voltage and the grid low voltage.

If, for example, the grid high voltage is set to –480V (pattern 1), the grid low voltage is –350V.

8-15

Purpose

Function

(Purpose)

Section

Adjustment/Operation test/check

Used to check and adjust the operation of the main charger grid voltage (low mode) in FAX mode and the control circuit.

Image process (Photoconductor/Developping/

Transfer/Cleaning)

Photo conductor

Operation/procedure

Enter the adjustment value and press the [OK] key, and output operation is performed for 30sec.

(Initial screen) (Executing screen)

Sim8-15 MHV(L) FAX

FAX 5

Sim8-15 MHV(L) FAX

FAX 5

EXEC [ 1- 8] 5 EXEC [ 1- 8] 5

Setting range 1-8

Default 5

NO.

Set value

1 480

2 505

3 530

Grid High Grid Low

–480V –350V

–505V

–530V

–375V

–400V

4

5

555

580

6 605

7 630

–555V

–580V

–605V

–630V

8 655 –655V

–425V

–450V

–475V

–500V

–525V

*1. The negative value of the set value corresponds to the grid high output voltage.

*2. The set values can be selected from the above 8 patterns only.

*3. The selected pattern determines the grid high voltage and the grid low voltage.

If, for example, the grid high voltage is set to –480V (pattern 1), the grid low voltage is –350V.

22

22-11

Purpose

Function

(Purpose)

Adjustment/Setting/Check

FAX related counter display

Operation/procedure

The current counter value (number of send/receive pages) of the FAX send/receive counter and the accumulated reception time and the print counter are displayed.

Note: Executable only when the FAX is installed.

24

24-10

Purpose

Function

(Purpose)

Adjustment/Setting/Check

FAX related counter clear

Operation/procedure

The current counter value (number of send/receive pages) of the FAX send/receive counter and the accumulated reception time and the print counter are cleared to 0.

Note: Executable only when the FAX is installed.

26

26-1

Purpose

Function

(Purpose)

Item

Setting

Used to set options. (This simulation is used to make option setting when an option is installed.)

Specifications Option

Operation/procedure

Set the job separator.

Sim26-1 OPTION SET.

JOB SEPARATOR 0

(0:NONE

1:JOB SEPARATOR)

[ 0- 1] 0

Set value

0

1

Connection option

None (default)

Job separator provided.

26-60

Purpose

Function

(Purpose)

Item

Setting

Used to set enable/disable of the FAX mode key when

FAX is not installed. (When FAX is installed, the FAX mode is enabled regardless of this setup.)

Operation

Operation/procedure

Input the set value with the 10-key and press the [OK] key.

This setup varies in connection with SIM 26-6 (Destination setup).

Sim26-60 FAX KEY

FAX KEY SETTING 0

(0:ON 1:OFF)

[ 0- 1] 0

Display items

0:ON

Content

Setting range

0-1

Default

JAPAN,

SEC, SECL,

SUK, SCA

Others

0 1

1:OFF

Effective (The message with FAX uninstalled is displayed.)

Disable (Error Beep)

AR-FX4 SIMULATION - 2

46

46-12

Purpose

Function

(Purpose)

Adjustment

FAX exposure level adjustment (batch)

Operation/procedure

Shading is performed to turn on the copy LED.

The current exposure value of "Normal character, Auto exposure" mode is displayed.

Enter an adjustment value of 2 digits with the 10-key and press the

START key, and the entered value will be set to all the modes and the self print will be made in the normal size.

Exposure adjustment value table

Mode

STD

(Standard character)

Fine

(Small character)

S-fine

(Fine)

U-fine

(Super fine)

AE

Auto

Manual

Auto

Manual

Auto

Manual

Auto

Manual

Auto

Manual

Auto

Manual

Auto

Manual

Auto

Manual

Photo

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Exposure adjustment

Individual adjustment

When initializing each data: 50

Note: Executable only when the FAX is installed.

enable

(46-13 to 16)

46-13 to 16

Purpose

Function

(Purpose)

Adjustment

FAX exposure level adjustment (individual)

Operation/procedure

The FAX exposure level can be adjusted separately for each mode by specifying a sub code. Since selection of Auto/Manual and Photo ON/

OFF is allowed separately for each mode, adjustments of 14 patterns in total can be made.

(Refer to 46-12, "Exposure adjustment table".)

Sub code

13

14

15

16

Mode

STD (normal character)

Fine (small character)

S-fine (super fine)

U-fine (super fine)

Shading is performed to turn on the copy LED.

The current exposure value of the selected mode is displayed.

Enter the 2-digit adjustment value with the 10-key pad and push

START key. The entered value is set for the specified mode, and the self print is made with the same magnification ratio for the mode.

Note: Executable only when the FAX is installed.

48

48-8

Purpose

Function

(Purpose)

Related soft

SW

Adjustment

FAX magnification ratio adjustment (read)

SW76-1 to 8, SW77-1 to 8

Operation/procedure

Adjust and set FAX document read magnification ratio, read and print the document.

Adjustment magnification ratio

Adjustment range

OC read main scanning magnification ratio

OC read sub scanning magnification ratio

SPF read main scanning magnification ratio

SPF read sub scanning magnification ratio

1 – 128 –

255%

Note: Executable only when the FAX is installed.

Adjustment unit

0.1% increment

48-9

Purpose

Adjustment

Function

(Purpose)

FAX magnification ratio adjustment (print)

Related soft SW

SW78-1 to 8, SW79-1 to 8

Operation/procedure

After the adjustment/setting of FAX print magnification ratio, read and print the document.

Adjustment magnification ratio

Main scanning magnification ratio

Sub scanning magnification ratio

Adjustment range

1 – 128 –

255%

Note: Executable only when the FAX is installed.

Adjustment unit

0.1% increment

48-10

Purpose

Adjustment

Function

(Purpose)

FAX auto reduction magnification ratio (print).

Related soft SW

SW25-1 to 4

Operation/procedure

Set the FAX auto reduction magnification ratio (0 to 15%).

Note:Executable only when the FAX is installed.

50

50-8

The adjustments on the machine side must have been normally completed.

Purpose

Function

(Purpose)

Adjustment

FAX lead edge adjustment (read)

Related soft SW

SW44-1 to 4, SW44-5 to 8

SW45-1 to 4, SW45-5 to 8

Operation/procedure

Adjust and set FAX document read lead edge position, read and print the document.

AR-FX4 SIMULATION - 3

66

B

A

OC read

Read area

C

Adjustment position

D

F

E

SPF read

Read area

Adjustment range

A OC read lead edge position

B OC read left edge position

C OC read rear edge position

D OC read right edge position

43 – 50 – 57 lines

43 – 50 – 57 dots

43 – 50 – 57 lines

43 – 50 – 57 dots

E SPF read lead edge position 43 – 50 – 57 lines

F SPF read left edge position 43 – 50 – 57 dots

G SPF read rear edge position 43 – 50 – 57 lines

H SPF read right edge position 43 – 50 – 57 dots

Note: Executable only when the FAX is installed.

G

Adjustment unit

8 lines

8 dots

8 lines

8 dots

8 lines

8 dots

8 lines

8 dots

H

66-3

Purpose

Function

(Purpose)

Adjustment/Setting/Check

FAX PWB memory check

Operation/procedure

Read/write can be checked for FAX PWB memory.

The check result is displayed separately for each memory.

1.

Memory to be checked

DRAM

SRAM

Flash ROM Program area

Memory area

SUM check only

Option memory The memory size follows the automatically detected value.

PAGE

2.

Detailed procedure

1 "55H" is written to all the addresses of each memory, and the address data are read in sequence to check that they were properly written.

2 "AAH" is written to all the addresses of each memory, and the address data are read in sequence to check that they were properly written.

3 "00H" is written to all the addresses of each memory, and the address data are read in sequence to check that they were properly written.

4 Perform checks 1 - 3 sequentially. If there is no abnormality, it is

"OK." If there is any abnormality, "NG" is notified to the error address.

5 After completion of check, the memory is returned to the initial state.

(CPU is not reset)

Interruption cannot be made during operation.

Note: Executable only when the FAX is installed.

50-9

Purpose

Adjustment

Function

(Purpose)

FAX lead edge adjustment (print)

Related soft SW

SW74-1 to 4, SW75-5 to 8

Operation/procedure

After the adjustment/setting of FAX print lead edge position, read and print the document.

66-1

Adjustment position

A Lead edge position

B Left edge position

Purpose

Function

(Purpose)

Adjustment range

43 – 50 – 57 lines

43 – 50 – 57 dots

Note: Executable only when the FAX is installed.

Adjustment/Setting/Check

FAX related soft SW setting

Adjustment unit

16 lines

16 dots

Operation/procedure

Display FAX software SW on LCD, and set/change those with 10-key.

Note: Executable only when the FAX is installed.

66-2

Purpose

Function

(Purpose)

Adjustment/Setting/Check

Initial set for the value of the FAX soft SW

Operation/procedure

Used to clear the FAX-related soft switches except for the line signal adjustment value and the machine adjustment value and to set default values (which differ depending on the country code separately entered.)

Note: Executable only when the FAX is installed.

AR-FX4 SIMULATION - 4

66-4

Purpose

Function

(Purpose)

Related soft

SW

Adjustment/Setting/Check

Signal send mode

SW5-5 to 8 (signals send level)

SW23-1 to 4 (RBT ON time)

SW23-5 to 8 (RBT OFF time)

SW43-1 to 5 (DTMF signal send time)

Operation/procedure

By setting the message No., the signal is sent to the line and the speaker of the body. (The signal is continuously sent until the interruption command is provided by pressing the [BACK] key.)

The signal send level can be selected from 0dB or the soft SW set value. However, the level setup is not required for 01, 31 - 35, the selection may does not appear. After completion of the mode, the signal send level is returned to the soft SW set value before execution of the mode.

01

26

Signal number

27, 28, 30

31

32

Tone signal

Send signal

Signal not send

7EH Flag signal

Pseudo-ringer sound

([ON HOOK] key ON)

Voice message (no sound)

Under the state where the ring back tone can be sent to the line, keep the sound composition IC volume to

0.

Send level

Selection menu

None

Yes

Yes

None

None

33

Signal number

Send signal

34

35

Ring back tone (no sound)

Under the state where the ring back tone can be sent to the line, keep the G/A volume to 0.

Dial pulse (make)

Maintain the make state with keeping the condition to be able to send to the dial pulse line.

Dial pulse (break)

Maintain the break state with keeping the condition to be able to send to the dial pulse line.

FFH Other than the above

Note: Executable only when the FAX is installed.

Send level

Selection menu

None

1: 0dB

2: Soft SW

1: 0dB

2: Soft SW

Yes

66-6

Purpose

Function

(Purpose)

Adjustment/Setting/Check

Printing the confidential password

Operation/procedure

The confidential ID table (confidential BOX numbers, confidential BOX names, and confidential password) is printed.

The confidential data of My company mode is printed separately.

Note: Executable only when the FAX is installed.

66-7

Purpose

Function

(Purpose)

Adjustment/Setting/Check

Print the screen memory contents

Operation/procedure

Used to input all image data (including confidential reception data, remote send image, not-sent image) stored in image memory of the

FAX section.

The output image is remained even after outputting.

Note: Executable only when the FAX is installed.

66-10

Purpose

Function

(Purpose)

Adjustment/Setting/Check

Image data memory clear

Operation/procedure

Used to clear all image data (including confidential reception data) stored in image memory of the FAX section.

The management table is also cleared (initialized) at the same time.

Note: Executable only when the FAX is installed.

66-11

Purpose

Function

(Purpose)

Adjustment/Setting/Check

300bps signals send

Operation/procedure

By setting the signal number, the specified signal is delivered to the line at the speed of 300bps. (The signal is continuously sent until the interruption command is provided by pressing the [BACK] key.)

The signal send level can be selected from 0dB or the soft SW set value.

The signal send level is returned to the soft SW set value before execution of the mode after completion of the mode.

Number

1

2

3

Signal

No signal (CML ON)

11111

11110

Number

4

5

6

Note: Executable only when the FAX is installed.

Signal

00000

010101

00001

66-13

Purpose

Function

(Purpose)

Adjustment/Setting/Check

Send test and adjustment of the dial pulse and

DTMF signal.

Related soft SW

SW53-1 to 4 (DTMF high group end level)

SW53-5 to 8 (DTMF low group send level)

SW67-1 to 4 (DP 10PPS make time)

SW67-5 to 8 (DP 10PPS make time)

Operation/procedure

The send test of dial pulse and DTMF signal is performed and the make time adjustment of dial pulse and the DTMF signal send level adjustment are performed if necessary.

1.

Dial pulse (10pps) send test

2.

Dial pulse (20pps) send test

• Used to set the make time. By performing the test, the registered dial pulse of max. 100 digits can be sent from the line.

• When "*" and "#" are included in the registered dial number, they are disregarded and the number is not processed as a dial.

• The make time set in the dial test is written into the corresponding soft SW.

• Default: 1 2 3 4 5 6 7 8 9 0

Operate the [

] [

] key in DP dial selection menu to switch.

(Time before pulse delivery can be changed as 2sec

4sec

8sec.)

3.

DTMF signal send test

• Set the signal send level to 0dB or the soft SW set value.

Used to set the high level group and the low level group of DTMF signal send level. By executing the test, DTMF signal is sent from the line to a recorded dial number of max. 100 digits.

• The high group/low group value of the DTMF signal send level set in the dial test is written into the corresponding soft SW.

• Default: 1 2 3 4 5 6 7 8 9 * 0 #

In the PB dial select menu, press [

][

] keys to select.

Pressing the [CLEAR] key during the operation clears the input value and returns to the value input menu.

• Max. 100 digits can be assigned to each dial (0 - 9, *, #). While the default value is displayed at first, a desired value can be entered and the entered value is stored on the FAX side until the menu is canceled.

• After completion of the mode, the signal send level is returned to the soft SW set value before execution of the mode.

Make time

Break time

DTMF signal adjustment

1ms for input value of 1. Adjust so that the dial pulse make rate is within 33±3%. (For North America,

40±3%.)

Dial pulse make rate =

Make time / (Make time + Break time)

It is obtained from the formula below and automatically set.

PPS = 1000 / (make time + break time)

The signal send levels are classified into the high group and the low group. The send level is 0.5dB for each 1 of input value.

Note: Executable only when the FAX is installed.

AR-FX4 SIMULATION - 5

66-17

Purpose

Function

(Purpose)

Adjustment/Setting/Check

DTMF signal send

Related soft SW

SW53-1 to 4 (DTMF high group end level)

SW53-5 to 8 (DTMF low group send level)

Operation/procedure

Set the signal send level to 0dB or the soft SW set value, and specify one dial to be delivered to.

The DTMF signal of the specified dial number is delivered until the interruption command is provided by pressing the [BACK] key.) When another dial number is specified during delivery of the signal, the new dial number is delivered.

The signal send level is returned to the soft SW set value before execution of the mode after completion of the mode.

Note: Executable only when the FAX is installed.

66-21

Purpose

Function

(Purpose)

Adjustment/Setting/Check

FAX information print

Operation/procedure

The following FAX information is printed.

Print information

1 User switch list

2 Soft SW list

3 Dump list

4 System error

Details

5 Protocol monitor

Used to print the system error log (error number and time). For this operation, the system error log is always stored as the ring buffer in the SRAM 256byte area.

Regardless of soft SW19-1 status, the protocol monitor of the preceding communication is printed. (Printing is allowed at any time before starting the next communication.) For this operation, the protocol monitor of one communication is always buffered.

Note: Executable only when the FAX is installed.

66-30

Purpose

Function

(Purpose)

Adjustment/Setting/Check

Recognize TEL/LIU state change.

Operation/procedure

When the relay state of the polarity reverse relay, the external telephone hook switch is changed, the content of change is displayed regardless of the soft SW setup. The display of change is kept until an interruption command is supplied by pressing the [BACK] key.

Check signal

HS2

HS1

RHS

EXHS

Notification contents

Signal low

Signal high

ON

ON

Note: Executable only when the FAX is installed.

OFF

OFF

66-32

Purpose

Adjustment/Setting/Check

Function

(Purpose)

Receive data check

Operation/procedure

The data received from the line are checked to insure that the following reception data are identical to the judgment data. If identical, "OK" is notified. If not, "NG."

A judgment is made according to the reception start data. Continuous coincidence is required.

Receive speed

Receive data

Number of judgment data

300bps

00

100

Note: Executable only when the FAX is installed.

66-34

Purpose

Function

(Purpose)

Adjustment/Setting/Check

Communication time measurement display

Related soft SW

SW10-1

Operation/procedure

The send/receive test is performed, and the time required for send/ receive of the image data in the test is measured and displayed.

Setup on the user side when executing communication

Measuring range

Communication means

Picture quality

Density

ECM

Sender information

: Memory send

: Normal Character

: Lighter

: ON

: OFF

Send From flag reception before sending of image data until sending of RCP frame

Receive From flag reception before reception of image data until reception of RCP frame

Mode when measuring Used to make communication not in a simulation process but in the normal screen and measure the time.

How to check the time Enter the simulation for communication time check and check the time.

Measuring unit msec

When there are two or more send/receive operations of image data in one communication, only the time of the last send/receive data near the end is measured.

Note: Executable only when the FAX is installed.

66-37

Purpose

Function

(Purpose)

Adjustment/Setting/Check

Speaker sound volume adjustment

Related soft SW

SW 86-1, 2 (call sound)

SW 85-1, 2 (line monitor sound)

SW 84-1, 2 (on hook)

SW 88-1, 2 (read end sound)

SW 89-1, 2 (communication end sound)

SW 87-1, 2 (DTMF send sound)

SW75-1, 2 (send end sound length)

SW75-3, 4 (receive end sound length)

AR-FX4 SIMULATION - 6

Operation/procedure

The following test sound is delivered to the line and the speaker to adjust the sound kind and volume.

The send level to the line is the set value of soft SW.

The set values of the selected sound kind and volume are written to each soft SW.

1.

Sound kinds pattern

Sound kinds

(Test sound)

Sound volume set value

0 1 2

1 Call sound

2 Lline monitor sound

(Test sound :

Communication signal sound)

3 On hook

(Test sound :

Communication signal sound)

4 Read complete sound

5 Communication end sound

6 DTMF signal send sound

NS

NS

Setting

Disable

NS

NS

NS

S

S

S

S

S

S

NS=No Sound S=Small M=Medium L=Large

2.

Sound volume pattern

M

M

M

M

M

M

3

L

L

L

L

L

L

Sound volume

Pattern

01 to 35

01 to 35

01 to 35

01 to 35

01 to 35

01 to 35

10

11

12

13

06

07

08

09

Sound volume

01

02

03

04

05

14

15

16

17

18

19

S

S

S

S

S

S

1 2 3 4 5 6 7

S M L

S M

S M

VR set value

L

L

L S M

S M

S

S

S

S

M

M

M

M

L

L

L

L

L

S M L

S M

S M

S M

M L

M

M

L

L

M L

M L

M L

L

L

L

S=Small M=Medium L=Large

Note: Executable only when the FAX is installed.

29

30

31

32

25

26

27

28

Sound volume

20

21

22

23

24

33

34

35

VR set value

1 2 3 4 5 6 7

S M L

S

S

M

M

L

L

S

S

S

M L

M L

M L

S

S

S

S M L

S M

S M

L

L

M L

M L

M L

S M L

S M

S M

L

L

S M L

66-38

Purpose

Adjustment/Setting/Check

Function

(Purpose)

Time setting/check

Operation/procedure

Read/write the time (year, month, day, min., sec.) on RTC of FAX

PWB.

Note: Executable only when the FAX is installed.

66-50

Purpose

Function

(Purpose)

Adjustment/Setting/Check

The FAST area of SRAM is cleared.

Operation/procedure

Only the SRAM area where data related to FAST are stored is cleared.

Note: Executable only when the FAX is installed.

AR-FX4 SIMULATION - 7

[6] SOFT SWITCH DESCRIPTIONS

1. Quick reference of FAX soft SW setup change

Large item

Dial (calling)

Reception

Medium item

Remote party calling inhibited

G3/SG3

Switch content

Pause time

Dial calling signal

DTMF related items

CSI transmission

Max. reception length

Key operator

Initial setup

Initial setup

NO

NO

Soft SW No.

Purpose of use

SW 38-1 – 4 When dial inhibited/erroneous dial

SW 41-1, 2 When dial inhibited

SW 53-1 – 4 When dial inhibited in PB (PBX/FAX service, etc.)

SW 53-5 – 8 When dial inhibited in PB (PBX/FAX service, etc.)

Redialing

Reception

(receiving call)

External telephone

Setup of external telephone

Remote switch number

Remote switch setup

Communication General

Transmission

Pulse (10PPS)

Signal detection Busy tone detection

Busy tone detection

Dial tone detection

When error

When error

When busy

When busy

When CI detection inhibited

Recall interval

Number of times of recall Send function setup

Recall interval

Number of times of recall Send function setup

CI detection

CI signal OFF detection time

YES/NO

NO

NO

NO

NO

Send function setup

Send function setup

NO

NO

Initial setup

SG3

G3/SG3

SG3

G3

Input of 2-digit number

YES/NO

Transmission level

JBIG mode

V34 symbol rate

DIS reception confirmation

Line equalizer

V34 transmission speed

NO

Initial setup

NO

NO

NO

V34 mode function setup NO

NO SW 58-1 – 6 When SG3 communication errors occur frequently

Rapid key/speed dial, etc. SW 6-8 When an error occurs in phase B

NO

Rapid key/speed dial, etc.

Manual transmission V34 NO

NO

SW 43-1 – 5 When dial inhibited in PB (PBX/FAX service, etc.)

SW 67-1 – 4 When dial inhibited with pulse

SW 7-3

SW 4-5 – 8

SW 40-5 – 8

SW 12-6, 7

SW 16-2

When busy tone detection inhibited

SW 15-1 – 3 When busy tone detection error

SW 7-4

SW 4-1 – 4 When transmission errors occur frequently

SW 40-1 – 4

When line is busy frequently

No reception

SW 55-1 – 7 No reception

When connecting external telephone

SW 2-5 – 8 When remote switch is erroneously detected

SW 8-5 When remote switch is erroneously detected

SW 5-5 – 8 When remote machine cannot receive signals at a proper level.

SW 10-8

SW 52-7

When an error occurs in JBIG mode

When SG3 communication errors occur frequently

SW 5-1, 2 It is set depending on the distance with the station when a communication error occurs.

When an error occurs in SG3 communication.

SW 52-6

SW 6-5

When SG3 communication error occurs in

FAX service, etc.

When V29 communication error occurs.

V29 no-modulation carrier

Modem transmission speed

RTN reception error

Rapid/speed dial, etc.

NO

SW 15-5 – 8 For certain/uncertain destinations

SW 52-5 When the result is OK though RTN is received.

NO

NO When receiving a document of 1m or more length

SG3

Proxy reception

Prevention against EQM dissipation

V34 reception speed

NO

NO

NO

G3 Countermeasure for echo in reception

NO

Reception modem speed NO

EYE-Q check only NO

When line is in bad condition and errors occur frequently.

When fall-down frequently occurs in SG3 communication.

When an error occurs in phase B of reception.

SW 7-7, 8 When line is in bad condition and fall-back or errors occur frequently.

SW 72-1 Change in detection method of training error

AR-FX4 SOFT SWITCH DESCRIPTIONS - 1

Large item Medium item Switch content

Reception print Paper selection Sub scan length judgment

NO

Key operator

Output condition setup Reception function setup

Soft SW No.

Purpose of use

When print is not made on selected paper.

Index

Automatic reduction print Reception function setup

Magnification ratio in automatic reduction

Index print setup

NO

Rotation reception print NO

Reception size setup Reception function setup

Reception function setup

To make divided print instead of reduction print

When reduction print is not made.

When reduction print is not made on a fixed size paper.

When rotation print is not made.

Reception capacity is indicated on the transmission machine.

When an index is added to received data.

2. Soft switch list

When outside the set range, the default value is automatically set.

Never change the soft switch setup which are inhibited to use.

SW

NO.

Data

No.

Item

1 Size specification

Switch selection and contents of functions

2

Bit No.

Centimeter size

Inch size

Conforms to the machine information.

Conforms to the machine information.

1 2

0 0

1 0

0 1

1 1

S

W

1

3 Inhibited to use

4 Auto/Manual default setup

1: Manual reception 0: Automatic reception

S

W

2

S

W

3

7

8

5 Send request protection 1: Not protected

6 Reduction send mode 1: Normal

1: Not print 7 Contents of send document are printed in memory send error

8 Inhibited to use

3

4

1 Inhibited to use

2

5 Remote selection

6 number setup

Binary input

Bit No.

Set range

1 Density default setup

2

3

Bit No.

Auto

Light

Slightly light

Medium

Slightly dark

Dark 4

5

6 Image quality priority selection

7

8

Bit No.

Normal

Fine

Super fine

Ultra fine

Not used

Fine + half-tone

Super fine + half-tone

Ultra fine + half-tone

0: Protected

0: Reduction

0: Print

5 6 7 8

0 to 9

1 2 3 4 5

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

0 0 1 0 0

0 0 0 1 0

0 0 0 0 1

6 7 8

0 0 0

0 0 1

0 1 0

0 1 1

1 0 0

1 0 1

1 1 0

1 1 1

Initial value Remark

Conforms to the machine information.

Automatic reception

0

1

When set to conformity to the machine information, if machine information is uncertain, set to centimeter size.

0

0

Manual reception can be set only when external telephone is connected.

Protected

Reduction

0

0

Print

5

0

0

0

0

0

0

0 When a value

1 outside the set

0 range is set, the initial value is

1 set.

0

Auto

0

0

0

0

0

Normal 0

0

AR-FX4 SOFT SWITCH DESCRIPTIONS - 2

SW

NO.

Data

No.

Item

1 Recall interval in

2 communication error

3

4

S

W

4

Switch selection and contents of functions

Binary input

Bit No.

Set range

5 Recall interval in busy Binary input

6 Bit No.

7

8

Set range

1 2 3

0 to 15min

4

0: Immediate recall after disconnection of line

5 6 7

1 to 15min

8

1 2

0 0

0 1

1 0

1 1

S

W

5

1

2

Line equivalent unit [km] Bit No.

No Filter

1.8km

3.6km

7.2km

3 Inhibited to use

4

5 Signal send level

6

7

8

1 ECM

2 CED signal send

3 CSI transmission

4 DIS reception confirmation in G3 send

Binary input

Bit No.

Set range

1: YES

1: YES

1: YES

1: 2 times

5 6

–5 to –20dBm

0: NO

0: NO

0: NO

7 8

0: Once in NFS reception

2 times in DIS reception

S

W

6

0: NO

0: 13sec

0: 75ms

S

W

7

5 Non-modulation carrier in V.29 send

6 EOL detection timer

7 Countermeasure for echo in reception

(CED tone send interval)

8 Countermeasure for echo in transmission

(After reception of DIS, hold time up to signal send is set.)

1 MH fixed

1: YES

1: 25sec

1: 500ms

1: 500ms

1: YES

2 Dial tone detection

3 Busy tone detection

4 Dial tone monitoring time

1: YES

1: YES

1: 10sec

5 Inhibited to use

6 Max. length of reception 1: No limit

7 Modem speed in reception fixed

Bit No.

No fixing

8

V.29-9600BPS

V.27ter-4800BPS

V.17-14400BPS

0: 200ms

0: NO (depending on the other party’s machine)

0: NO

0: NO

0: 5sec

0: 1.5m

7 8

0 0

0 1

1 0

1 1

Initial value Remark

1min

3min

No Filter

–12dBm

YES

YES

YES

Once in NFS reception, 2 times in

DIS reception

0

1

1

1

1

1

0

1

0

1

0

0

0

1

0 When a value

0 outside the set

1 range is set, the

1 initial value is set.

0

0

When a value outside the set range is set, the initial value is set.

NO

13sec

0

0

75ms

200ms

NO

NO

YES

5sec

1.5m

No fixing

0

0

0

0

1

0

0

0

0

0

AR-FX4 SOFT SWITCH DESCRIPTIONS - 3

SW

NO.

S

W

8

S

W

9

S

W

10

S

W

11

S

W

12

Data

No.

Item

1 Memory transmission/ direct transmission default setup

2 Proxy reception

3 Printing the content of transmitted document in normal memory transmission

4 Judgment of system No. in bulletin transmission

5 Remote reception indication

6 Inhibited to use

1: YES

1: Not print

1: Allow

1: YES

Switch selection and contents of functions

1: Direct transmission 0: Memory transmission

0: NO

0: Print

0: Inhibit

0: NO

7

8

1 Print of total communication time and total pages

2 Inhibited to use

1: YES 0: NO

3 Quick memory transmission

4 Yes/No of SUB capacity in reception

1: Allow

1: NO

5 F-code relay broadcast function

6 F-code confidential reception function

7 Yes/No of SEP capacity in reception

8 Yes/No of reception

PWD capacity

1: Inhibit

1: Inhibit

1: NO

1: Send without password

1 Measurement of communication time

(image)

2 Sender’s telephone number registration

1: YES

1: Inhibit

0: Inhibit

0: YES

0: Allow

0: Allow

0: YES

0: Disconnection of line with

DCN

0: NO

0: Allow

0: Disconnection of line with

DCN

0: NO

3 Yes/No of reception SID capacity

4 SDT signal detection

1: Send without password

1: YES

5 Inhibited to use

6

7 ECM MMR mode

8 ECM JBIG mode

3

4

1 Inhibited to use

2

1: YES

1: YES

7

8

5

6

3

4

1 Inhibited to use

2

5

6 CI detection

7

Bit No.

4 sine wave

3 sine wave

2 sine wave

0: NO

0: NO

6

0

7

0 0

1 0

1

1 1

8 Inhibited to use

Initial value

Memory transmission 0

YES 1

Not print

Inhibit

YES

YES

1

Allow

YES

Allow

Allow 0

YES 0

Disconnection of line with DCN

0

YES 1

1

1

1

0

0

0

1

0

1

0

Remark

Allow 0

Disconnection of line with DCN

NO

0

YES

YES

4 sine wave

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

0

0

0

0

0

When a value outside the set range is set, the initial value is set.

0

AR-FX4 SOFT SWITCH DESCRIPTIONS - 4

SW

NO.

S

W

13

S

W

14

S

W

15

S

W

16

3

4

5

6

Data

No.

Item

1 Inhibited to use

2

Switch selection and contents of functions

7 Relay data output

8 Relay broadcast function

1 V.34 mode sending

2 speed

3

4

5 V.34 mode reception

6 speed

1: YES

1: Allow

Binary input

Bit No.

Sending speed =

2400(bps) x N

7

8

1 Lower limit of speaker sound detection time

2 Upper limit of speaker sound detection time

Binary input

Bit No.

Reception speed =

2400(bps) x N

1: 350ms

1: 650ms

3 Lower limit 2 of speaker sound detection time

4 Inhibited to use

5 Modem speed

(V.33 mode or below)

6

1: 150ms

Bit No.

V.27 2400bps

V.29 9600bps

V.27 4800bps

7

8

V.29 7200bps

V.33 14.4kbps

V.33 12.0kbps

V.17 9600bps

V.17 12.0kbps

V.17 7200bps

V.17 14.4kbps

1 Inhibited to use

2 External telephone connection

3 Inhibited to use

4

5 Rotation transmission selection

(11 x 8.5

8.5 x 11)

6 Rotation transmission selection (A4

A4R)

7 Rotation transmission selection (B5R

B5)

8 Rotation transmission selection (A5

A5R)

1 Paper selection priority sequence

2 Output condition setup

1: YES

1: YES

1: YES

1: YES

1: YES

1: Width priority

3

Bit No.

Reduction allowed

Division allowed

0: NO

0: Inhibit

1

Others

0: NO

0: NO

0: NO

0: NO

0: NO

3

0: 250ms

0: 750ms

4

When N=0, 2400bps.

When N=15, 33600bps.

5

When N=0, 2400bps.

When N=15, 33600bps.

0: Follows SW15-1.

5

0

0

0

0

0

0

1

1

1

2

0

1

2

6

6

0

0

0

0

1

1

0

0

0

3

0

0

7

7

0

0

1

1

0

1

0

1

1

8

8

0

1

0

1

0

0

1

0

1

0: Area priority

S

W

17

7

8

4 Inhibited to use

5

6

Initial value

YES

Allow

33600bps

33600bps

250ms

750ms

Follows SW15-1.

0

0

0

1

1

1

1

0

1

0

1

1

0

0

0

0

0

0

1

0

1

V.17 14.4kbps

0

0

Remark

0

YES

YES

0

1

0

0

1

YES

YES

YES

1

1

1

Area priority

Reduction allowed

0

0

1

1

1

1

0

0

When a value outside the set range is set, the initial value is set.

AR-FX4 SOFT SWITCH DESCRIPTIONS - 5

SW

NO.

S

W

18

S

W

19

S

W

20

S

W

21

Data

No.

Item

1 Inhibited to use

2

3 Reception size

4 specification

(Indicates reception capacity.)

5 11 inch reception capacity setup

6 Output method in A3 width reception (Inch series)

7 Output method in A4 width reception (Inch series)

8 Override print setup

1

Protocol monitor

2 Inhibited to use

3 Output only in protocol monitor error

Bit No.

3 4

By the attached cassette 0 0

B4 (A4/B4) 0 1

A4

A3 (A4/B4/A3)

1: 255mm or 215mm

1: 297mm width

1: Data of 8.5 inch width is printed

1: Override print allowed

1: YES

1: YES

4 Protocol monitor save 1: Save

5 Inhibited to use

1: YES 6 Recording table automatic print

7 Time specification 1 of communication record table

1: Allow

8 Time specification 2 of communication record table

1 Line sound monitor range

1: Allow

2

Bit No.

OFF

Up to NSF signal send/ receive

All

1: YES

Switch selection and contents of functions

1: Not output

1 0

1 1

0: 303mm or 255mm or

215mm

0: 11 inch width

0: Data of 210mm width is printed

0: Override print inhibited

0: NO

0: NO

0: Disable

0: NO

0: Inhibit

0: Inhibit

1 2

0 0

0 1

1 0

1 1

0: NO

0: Output

3 Line monitor display

4 Data output specification in communication error during reception

5 Receivable memory capacity

6 Memory over during reception

7 Flag-adrs timer setup

(V.21-FSK)

8

1: 64Kbyte

1: Output

Bit No.

6sec

15sec

30sec

120sec

Binary input

Bit No.

Set range

0: 128Kbyte

0: Not output

7

0

0 1

1 0

1 1

1

8

0

2 3 4

0 to 255sec

5 6 7 8

6

7

8

1 Interval between

2 completion of

3 communication and the

4 next call

5

Initial value

0

By the attached cassette

0

303mm or 255mm or

215mm

0

11 inch width

0

8.5 inch width print

YES

Inhibit

128Kbyte

Output

0

1

0

0

0

0

0

0

1

0

0

0

1

0

1

Override print allowed 1

NO 0

0

NO

Save

0

1

0

1

0

Remark

Inhibit 0

Up to NSF signal send/ receive

0

When a value outside the set range is set, the initial value is set.

1

NO 0

Output 0

6sec

1sec

AR-FX4 SOFT SWITCH DESCRIPTIONS - 6

SW

NO.

S

W

22

S

W

23

S

W

24

Data

No.

Item

1 Inhibited to use

2

3

4

5

6

7

8

1 Inhibited to use

2

3

4

5

6

7

8

1 Image capacity at send request

2

Switch selection and contents of functions

Bit No.

Ultra fine

Super fine

Fine

Normal

1: Refuge specified number reception

1: Refuge specified number reception

1

0

0

1

1

2

0

1

0

1

0: Ignore specified number reception

0: Ignore specified number reception

S

W

25

S

W

26

S

W

27

3 Specified number reception

4 Specified number reception when manual reception

5 Inhibited to use

6 Document output setup in reception

7 Inhibited to use

8 Automatic reduction print

1 Automatic reduction

2 rate setup

3

6

7

4

5 Inhibited to use

2

3

8

1 Inhibited to use

6

7

4

5

8

1 Inhibited to use

2 Recording paper tray selection

(Tray 1)

3 Recording paper tray selection

(Tray 2)

4 Recording paper tray selection

(Tray 3)

5 Recording paper tray selection

(Tray 4)

6 Inhibited to use

7

8

1: Collective output after completion of reception.

1: Allow

Binary input

Bit No.

Set range

1: ON

1: ON

1: ON

1: ON

0: Output after reception of every page

0: Inhibit

1 2

0: OFF

0: OFF

0: OFF

0: OFF

3

0 to 15%

4

Initial value

0

Ultra fine

0

Ignore specified number reception

0

Ignore specified number reception

0

0

Output after reception of every page

0

0

Allow

6%

1

0

1

0

1

0

0

0

0

0

0

0

0

0

0

0

1

1

ON 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

ON

ON

ON

1

1

1

0

0

0

Remark

AR-FX4 SOFT SWITCH DESCRIPTIONS - 7

SW

NO.

S

W

28

S

W

29

S

W

30

Data

No.

Item

1 Inhibited to use

2

3

4

5

6

7

8

1 Inhibited to use

2

3

4

5 Setup of number of

6 times of call rings

7

8

1 Report output when canceling

2 Inhibited to use

3 Rotation print

4 Department management

5 Default data, sender print

6 Department name notification

7 Date/sender print position setup

8 Report output (in confidential reception)

1 Report output (in transmission)

1: Output

1: Allow

1: Allow

1: ON

1: ON

1: Print

Switch selection and contents of functions

Binary input

Bit No.

Set range

1: Inside of document

5 6 7

0: Inhibit

0: Inhibit

8

0 to 9 times

0: Not output

0: OFF

0: OFF

0: Outside of document

0: Not print

S

W

31

2

3 Report output

4

5

6

(In broadcast, sequential send request, and relay broadcast)

Report output (in reception)

Bit No.

Print inhibited

All print

Only when transmission is failed.

1 2

0 0

0 1

1 0

Bit No.

Print inhibited

All print

Only the address to which transmission is failed

1 1

3 4

0 0

0 1

1 0

Bit No.

Print inhibited

All print

Only in error

1 1

5 6

0 0

0 1

1 0

1 1

7 Inhibited to use

8

1 Distinctive ring

S

W

32

2

3

4

Bit No.

OFF

Standard/ON

Pattern1

Pattern2

Pattern3

Pattern4

Pattern5

1 2 3 4

0 0 0 0

0 0 0 1

1 0 0 0

0 1 0 0

1 1 0 0

0 0 1 0

1 0 1 0

5 Inhibited to use

6 Index print setup

7 Inhibited to use

8

1: Print 0: Not print

Initial value

2 times

Not output

Allow

Inhibit

ON

OFF 0

Outside of document 0

Print 1

0

1

1

0

0

0

0

0

0

0

0

0

0

1

0

0

0

0

1

0

1

Only when transmission is failed.

1

0

Remark

0

All print

1

Print inhibited

OFF

Not print

0

0

0

0

0

0

0

1

0

0

0

Other than

U.S.A., Canda,:

OFF (fixed)

Australia: ON/

OFF only

0

AR-FX4 SOFT SWITCH DESCRIPTIONS - 8

SW

NO.

S

W

33

S

W

34

Data

No.

Item

1 Page number print setup

2 Inhibited to use

3

4

5

6

7

8

1 Inhibited to use

7

8

5

6

2

3

4

1 Cover function default setup

2 Inhibited to use

3 CI delete max. OFF time

S

W

35

4

S

W

36

S

W

37

S

W

38

5 Inhibited to use

6

7

2

3

8

1 Inhibited to use

6

7

4

5

2

3

8

1 Inhibited to use

6

7

4

5

2

3

8

1 Pause time setup

4

1: YES

1: YES

Bit No.

5sec

Switch selection and contents of functions

10sec

15sec

20sec

Binary input

Bit No.

Set range

5 Inhibited to use

6

7 Transfer function

8 Inhibited to use

1 Call time setup in

2 automatic transmission

3

(T0 timer setup)

1: Allow

Binary input

Bit No.

Set range

0: NO

0: NO

1

1 to 15sec

0: Inhibit

1

2

2

3

3

30 to 60sec

5sec unit

4

S

W

39

3 4

0 0

0 1

1 0

1 1

7

8

4 Inhibited to use

5

6

AR-FX4 SOFT SWITCH DESCRIPTIONS - 9

Initial value

YES

NO

10sec

2sec

Inhibit

45sec

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Remark

1

0

0

0

0

0

0

1

0

1

0

0

0

1

0

1

0

0

0

0

1

0

0

0

1

0 When a value

0 outside the set

1 range is set, the initial value is

0 set.

0

0

0

0

0 When a value

1 outside the set range is set, the

1 initial value is set.

1

SW

NO.

Data

No.

Item

1 Number of times of

2 recall in error

3

4

S

W

40

7

8

5 Number of times of

6 recall in busy

1 Tone/Pulse default setup

2

3

Telephone line menu

Switch selection and contents of functions

Binary input

Bit No.

Set range

1 2 3 4

0 to 1 times

Binary input

Bit No.

Set range

Bit No.

10PPS

20PPS

TONE

1: Inhibit

5

1

0

0

1

1

6

2

0

1

0

1

7

0: Allow

8

0 to 14 times

S

W

41

4 Maintenance system

5 F.A.S.T mode 1: YES 0: NO

S

W

42

S

W

43

S

W

44

6 Sequence of year/ month/day in LCD, report, and sender

7 record

Bit No.

Year/Month/Day

Month/Day/Year

Day/Month/Year

8 Time display format

1

Direct send recall Allow/

Inhibit

2 Inhibited to use

3

4 Manual/Auto reception auto swiching

5 Number of auto switch

6 calls of manual

7 reception

auto

8 reception

1: am/pm

1: Allow

1: Allow

Binary input

Bit No.

Set range

2

3

1 DTMF signal send time Binary input

Bit No.

Set range

4

5

6 Maintenance cycle

7

Bit No.

50K

25K

12.5K

8

1 Scan effective image

2

3

4 area (OC)

Main scan

Left edge image loss

5K

Others

1: –

Binary input

Bit No.

Set range

5 Scan effective image

6 area (SPF)

7

Main scan

8

Left edge image loss

1: –

Binary input

Bit No.

Set range

6 7

0 0

0 1

1 0

1 1

0: 24H

0: Inhibit

0: Inhibit

5 6 7 8

1 to 9

1 2 3

10ms unit

6 7 8

0 0 1

0 1 0

0 1 1

1 0 0

FREE

0: +

4

60 to 310ms

2 3 4

0 to ±56 dots

8 dot interval

0: +

6 7 8

0 to ±56 dots

8 dot interval

5

Initial value

1 times

2 times

TONE

Allow

NO

Month/Day/Year am/pm

Allow

Inhibit

9 times

110ms

50K

+

+0 dot

+

+0 dot

0

1

0

0

0

0

0

0

0

0

Remark

1

0

0

0 When a value

0

0 outside the set range is set, the

1 initial value is set.

0 When a value

0 outside the set

1 range is set, the initial value is

0 set.

1

0

When a value outside the set range is set, the initial value is set.

0

Japan, U.S.A.,

Canada: Fixed to “Allow”

0

0

0

1

Fixed to NO for other than

U.S.A. and

Canada.

When a value outside the set range is set, the initial value is set.

1

0

1 When a value

0 outside the set

0 range is set, the

1 initial value is set.

0 When a value

1 outside the set

0 range is set, the

1 initial value is

1 set.

0

AR-FX4 SOFT SWITCH DESCRIPTIONS - 10

SW

NO.

S

W

45

S

W

46

S

W

47

S

W

48

S

W

49

S

W

50

S

W

51

Data

No.

Item

1 Scan effective image

2

3 area (OC)

Main scan

4

Right edge image loss

5 Scan effective image

6 area (SPF)

7

8

Main scan

Right edge image loss

1: –

Binary input

Switch selection and contents of functions

0: +

Bit No.

Set range

2 3 4

0 to ±56 dots

8 dot interval

0: + 1: –

Binary input

Bit No.

Set range

6 7 8

0 to ±56 dots

8 dot interval

1 Inhibited to use

2

3 Priority in the day of week

4 Inhibited to use

7

8

5 Daylight saving tive

6 Inhibited to use

1 Time specification print

2

1 (O’clock) in the

3 communication report

4 table

7

8

5

6 Inhibited to use

1 Time specification print

2

1 (min) in the

3 communication report

4 table

5

6

7 Inhibited to use

8

1 Time specification print

2

2 (O’clock) in the

3 communication report

4 table

7

8

5

6 Inhibited to use

1 Time specification print

2

2 (min) in the

3 communication report

4 table

5

6

7 Inhibited to use

8

3

4

1 Inhibited to use

2

5

6 CED detection time

7 Busy tone detection cycle

8

1: YES

1: Allow

Binary input

Bit No.

Set range

Binary input

Bit No.

Set range

Binary input

Bit No.

Set range

Binary input

Bit No.

Set range

1: 500ms

Bit No.

2puls

4puls

6puls

10puls

0: NO

0: Inhibit

1

00 to 23 o’clock

1 2

0: 1000ms

7 8

0 0

0 1

1 0

1 1

3 4

00 to 59min

1

00 to 23 o’clock

1

2

2

2

3

3

3

4

4

4

00 to 59min

5

5

5

5

6

6

AR-FX4 SOFT SWITCH DESCRIPTIONS - 11

Initial value

+

+0 dot

+

+0 dot

NO

Inhibit

0 o’clock

0 min

0 o’clock

0 min

1000ms

2puls

Remark

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0 When a value

0 outside the set

0 range is set, the

0 initial value is

0 set.

0

0

0

0 When a value

0 outside the set

0 range is set, the

0 initial value is

0 set.

0

0

0

0 When a value

0 outside the set

0 range is set, the

0 initial value is

0 set.

0

0

0

0

0

0

0

0

0

0 When a value

0 outside the set

0 range is set, the

0 initial value is

0 set.

0

0

0

SW

NO.

S

W

52

S

W

53

S

W

54

Data

No.

1

2

Busy tone detection level

Item

3 ERR frame reception operation

4 Inhibited to use

5 Error process in RTN reception

6 V.34 mode function in manual communication

7 V.34 mode function

8 V.34 control channel communication speed

1 DTMF send level

2

(High group) setup

3

4

5 DTMF send level

6

(Low group) setup

7

8

1 Scan effective image

2 area (OC)

3

Sub scan

4 lead edge image loss

5 Scan effective image

6 area (SPF)

7

Sub scan

8 lead edge image loss

Bit No.

–43dB

–35dB

–33dB

–30dB

1: Continues process.

1: Not error

1: ON

1: ON

1: 2400bps

Switch selection and contents of functions

Binary input

Bit No.

Set range

Binary input

Bit No.

Set range

1: –

Binary input

Bit No.

Set range

1: –

Binary input

Bit No.

Set range

1

0

0 1

1 0

1

0: Not continue process.

(Error)

0: Error

0: OFF

0: OFF

0: 1200bps

1

2

0

1

2 3

0 to 7.5db

4

0.5dB interval

5 6 7 8

0 to 7.5db

0.5dB interval

0: +

2 3 4

0 to ±56 line

8 line interval

0: +

6 7 8

0 to ±56 line

8 line interval

S

W

55

1 CI signal OFF detection

2 enable time

3

Binary input

Bit No.

Set range

6

7

4

5

8 EQM judgment threshold value

1: Loose

1 2 3

10ms unit

0: Tight

4

0 to 1270ms

5 6 7

S

W

56

S

W

57

6

7

4

5

1 Inhibited to use

2

3

6

7

8

4

5

2

3

8

1 Inhibited to use

Initial value Remark

0

–43dB

0

Not continue process.

(Error)

0

0

Error 0

ON

ON

1200bps

3.5db

3.5db

+

+0 line

+

+0 line

1200ms

Tight

0

1

1

1

0

0

1

1

0

0

1

0

0

1

1

0

0

0

0

0

0

1

0

1

1

1

0

0

0

0

0

1

0

0

0

0

0

0

0

0

0

0

0

Disable when

EQM Judge

Value is SRAM

AR-FX4 SOFT SWITCH DESCRIPTIONS - 12

SW

NO.

S

W

58

S

W

59

S

W

60

S

W

61

S

W

62

S

W

63

Data

No.

Item

1 V.34 3429 (baud)

Rate Mask

2 V.34 3200 (baud)

Rate Mask

3 V.34 3000 (baud)

Rate Mask

4 V.34 2800 (baud)

Rate Mask

5 Inhibited to use

6 V.34 2400 (baud)

Rate Mask

7 Inhibited to use

5

6

3

4

8

1 Inhibited to use

2

7

8

1 Inhibited to use

2

3

4

5 Countermeasures against V.34 communication error

(reception)

(Phase 2 error retry setup)

6 Countermeasures against V.34 communication error

(transmission)

(Phase 2 error retry setup)

5

6

3

4

7 Inhibited to use

8

1 Inhibited to use

2

5

6

3

4

7

8

1 Inhibited to use

2

5

6

3

4

7

8

7

8

1 Inhibited to use

2

1: YES

1: YES

Switch selection and contents of functions

1: supported

1: supported

1: supported

1: supported

1: supported

0: not supported

0: not supported

0: not supported

0: not supported

0: not supported

0: NO

0: NO

AR-FX4 SOFT SWITCH DESCRIPTIONS - 13

NO

0

1

0

0

0

0

0

0

0

0

0

1

1

0

0

0

0

0

1

0

1

0

1

1

0

1

1

Initial value supported supported supported supported supported

1

1

0

1

1

1

1

1

0

0

0

0

0

0

0

0

0

0

1

1

Remark

NO

0

SW

NO.

S

W

64

S

W

65

S

W

66

S

W

67

S

W

68

S

W

69

S

W

70

3

4

5 Inhibited to use

6

7

8

1 Inhibited to use

2

3

4

5 T1 timer setup

6

7

8

1 Inhibited to use

2

4

5

6

7

8

5

6

3

4

7

8

1 Inhibited to use

2

3

Data

No.

Item

1 Inhibited to use

2

3

4

5

6

7

8

1 Inhibited to use

2

3

4

5

6

7

8

1 Inhibited to use

2

5

6

3

4

7

8

1 Setup of make rate

2

(10PPS)

Switch selection and contents of functions

Binary input

Bit No.

Set range

Binary input

Bit No.

Set range

1

26 to 41ms

1ms interval

5

2

6

3

7

4

8

15 to 90sec

5sec interval

Initial value

40ms

40sec

0

0

0

0

0

0

0

0

0

0

0

1

0

0

0

0

0

1

0

1

1

0

0

0

0

0

0

0

1

0

1

1

0

1

0

0

1

0

0

0

0

1

0

0

0

1

1

0

0

0

1

0

0

0

0

1

Remark

AR-FX4 SOFT SWITCH DESCRIPTIONS - 14

SW

NO.

Data

No.

Item

1 Dial ringing wait time

S

W

71

S

W

72

S

W

73

S

W

74

S

W

75

Switch selection and contents of functions Initial value Remark

2

Bit No.

3.5sec

4sec

5sec

6sec

1 2

0 0

0 1

1 0

1 1

3.5sec

0

0

3 Inhibited to use

4

5

6

7 Silent detection level

8

1 EYE-Q check

Bit No.

– 43dBm

– 40dBm

– 39dBm

1: EYE-Q check only

7 8

0 0

0 1

–43dBm

1 0

0: 0 reception & EYE-Q check 0 reception & EYE-Q check

4

5

2 Inhibited to use

3

6

7

8

1 Inhibited to use

4

5

2

3

6

7 DIS reception process selection in reception

8

1 Print lead edge

2 adjustment (Lead edge

3 adjustment)

4

5 Print lead edge

6

7

8

1 Transmission end

2 adjustment (Rear edge adjustment) sound

(Buzzer sound length) setup

3 Reception end sound

4

(Buzzer sound length) setup

5 Print lead edge

6

7

8 adjustment (Left edge)

Bit No.

7 8

Command resend by judging that echo has been received 0 0

Line disconnection by judging as improper DIS 0 1

1 0 Polled send when there is polled document with DIS reception. In other cases, command resend by judging that echo has been received.

Polled send when there is polled document with DIS reception, command resend when judgement that transmitter has received echo, in other cases, shut down the line as ellegal DIS.

1 1

0: + 1: –

Binary input

Bit No.

Set range

2 3

16 line interval

0: +

4

0 to ±112 line

1: –

Binary input

Bit No.

Set range

Bit No.

3sec

1sec

Silent

6

16 line interval

1 2

0 0

0

1

7

1

0

1 1

3 4

8

0 to ±112 line

Bit No.

3sec

1sec

Silent

0

0

1

0

1

0

1 1

0: + 1: –

Binary input

Bit No.

Set range

6 7 8

0 to ±112 line

16 line interval

Command resend by judging that echo has been received

+

48 line

+

48 line

3sec

3sec

+

48 line

0

0

0

1

1

1

0

0

1

0

0

1

0

0

1

0

0

0

0

0

1

0

0

0

0

0

0

0

1

0

1

1

0

0

When outside the set range, the initial value is set.

0

Communi-cation error sound is generated even in silent setup

0

0

Communi-cation error sound is generated even in silent setup

0

AR-FX4 SOFT SWITCH DESCRIPTIONS - 15

SW

NO.

S

W

76

S

W

77

S

W

78

S

W

79

S

W

80

S

W

81

Data

No.

Item

4

5

1 Scan magnification ratio

2

3 adjustment OC

(main scan)

6

7

8

Switch selection and contents of functions

1: –

Binary input

Bit No.

Set range

0: +

2 3 4 5

0 to ±12.7%

0.1% interval

6 7 8

0: + 1 Scan magnification ratio

2 adjustment OC

3

(sub scan)

4

1: –

Binary input

Bit No.

Set range

7

8

5

6

1 Print magnification

2 ration adjustment (main

3 scan)

4

1: –

Binary input

Bit No.

Set range

2

2

3

0: +

3

4

4

5

0 to ±12.7%

0.1% interval

5

0 to ±12.7%

0.1% interval

6

6

7

7

8

8

7

8

5

6

1 Print magnification

2 ration adjustment (sub

3 scan)

4

7

8

5

6

1 Scan effective image

2 area (OC)

3

Sub scan

4

Rear edge image loss

5 Scan effective image

6 area (SPF)

7

Sub scan

8

Rear edge image loss

1: –

Binary input

1: –

Bit No.

Set range

Binary input

Bit No.

Set range

1: –

Binary input

Bit No.

Set range

0: +

2 3

0 to ±56 line

0: +

4

4

5

0 to ±12.7%

0.1% interval

0: +

2

8 line interval

6

3

7 8

0 to 28 line

2 line interval

0 = 14 line

6 7 8

3

4

1 Destination information Binary input

2 Bit No.

7

8

5 Language information Binary input

6 Bit No.

1

5

2

6

3

1: U.S.A.

2: Canada

7

1: English

4

8

S

W

82

6

7

8

4

5

1 Scan magnification ratio

2 adjustment SPF

3

(main scan)

1: –

Binary input

Bit No.

Set range

0: +

2 3 4 5

0 to ±12.7%

0.1% interval

6 7 8

Initial value

+

0%

+

0%

+

0%

+

0%

+

+0 line

+

+14 line

U.S.A.: 0 0 0 1

Canada: 0 0 1 0

English: 0 0 0 1

+

0%

Remark

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

0

0 For English, the

0 proper character

0 is determined by destination

1 information.

0

AR-FX4 SOFT SWITCH DESCRIPTIONS - 16

SW

NO.

S

W

83

S

W

84

S

W

85

S

W

86

S

W

87

S

W

88

Data

No.

Item

4

5

1 Scan magnification ratio

2

3 adjustment SPF

(sub scan)

2

3

4

5

6

7

6

7

8

1 On-hook speaker volume

On-hook pattern number

8

1 Line monitor speaker volume

1: –

Binary input

Bit No.

Set range

Bit No.

Not used

Small

Medium

Large

Switch selection and contents of functions

Binary input

Bit No.

Set range

Bit No.

Silent

Small

0: +

2 3

0 to ±12.7%

0.1% interval

1

0

2

0

0 1

1 0

1 1

3

1

4

2

0 0

0 1

1 0

1 1

4

5

5

6

6

7

7

8

8

Pattern number 1 to 35

2

5

6

3 Line monitor pattern

4 number

Medium

Large

Binary input

Bit No.

Set range

7

8

1 Ringing volume

4

5

Bit No.

Silent

Small

Medium 2

Large

3 Ringing pattern number Binary input

Bit No.

Set range

3 4

Pattern number 1 to 35

1

0

0

1

1

3

2

0

1

0

1

4

5

5

6

6

7

7

8

8

Pattern number 1 to 35

6

7

8

1 Speaker volume in

DTMF send

2

3

4

5

6

Pattern number in

DTMF send

7

8

1 Speaker volume at scanner scan end

2

Bit No.

Silent

Small

Medium

Large

Binary input

Bit No.

Set range

Bit No.

Silent

Small

Medium

Large

Binary input

Bit No.

Set range

1

0 0

0 1

1 0

1 1

3

Pattern number 1 to 35

1

0

0 1

1 0

1 1

3

2

4

2

0

4

5

5

6

6

7

7

8

8

Pattern number 1 to 35

6

7

8

3 Pattern number in

4 scanner scanning

5

AR-FX4 SOFT SWITCH DESCRIPTIONS - 17

Initial value

+

0%

0

0

0

0

0

0

0

0

1

Medium

21

0

1

0

1

0

1

0

1

Medium

21

0

0

1

0

1

0

1

1

Medium

21

0

1

0

1

0

1

0

1

Medium

21

0

0

1

0

1

0

1

1

Medium

21

0

1

0

1

0

1

0

Remark

SW

NO.

Data

No.

Item

1 Speaker volume of communication end sound

2

S

W

89

S

W

90

S

W

91

S

W

92

S

W

93

S

W

94

S

W

95

6

7

4

5

2

3

8

1 Inhibited to use

6

7

4

5

2

3

8

1 Inhibited to use

6

7

4

5

8

2

3

8

1 Inhibited to use

6

7

8

3 Pattern number of

4 communication end

5 sound

6

7

4

5

1 Inhibited to use

2

3

6

7

4

5

2

3

8

1 Inhibited to use

6

7

4

5

2

3

8

1 Inhibited to use

Bit No.

Silent

Small

Medium

Large

Binary input

Bit No.

Set range

Switch selection and contents of functions

1 2

0 0

0 1

1 0

1 1

3 4 5 6 7 8

Pattern number 1 to 35

Initial value

Medium

21

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

0

0

0

1

0

0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

0

0

0

0

1

0

1

0

1

Remark

AR-FX4 SOFT SWITCH DESCRIPTIONS - 18

SW

NO.

S

W

96

S

W

97

4

5

6

7

8

Data

No.

Item

1 Inhibited to use

2

3

4

5

6

7

8

1 Inhibited to use

2

3

3. Soft switch descriptions

SW1 No.1, No.2 Size specification

Used to set inch series or AB series for recording paper when printing received documents.

There is normally no need to change from "Depends on the machine information."

SW1 No.3 Inhibited to use

SW1 No.4 Auto/Manual default setup

Used to select Auto/Manual reception mode when turning on the power. (When no external telephone is connected, do not select Manual. However, setup is possible and reception can be made by onhook.)

When set to 1, manual reception.

When set to 0, auto reception.

Default: 0 (auto reception)

SW1 No.5 Send request protection

Used to set YES/NO of the confidential protection function (inhibition of transmission to an erroneous party). Confidential protection is performed by collating the number registered in this machine and that in the other party’s machine. (Sender’s telephone number

←→

Send request allow number, System number

←→

ID number)

When set to 1, protection is not made.

When set to 0, protection is made.

Default: 0 (protection enable)

SW1 No.6 Reduction send mode

Used to set whether the transmitted document is received in reduction size or both ends of recording paper are cut when the transmitted document width is greater than the recording paper width.

When set to 1, both ends are cut without reduction and transmitted.

When set to 0, it is reduced and transmitted.

Default: 0 (Reduction transmission)

SW1 No.7 Contents of send document are printed in memory send error

Used to set Print/Not print part of the sent document in the transmission result table in case of a memory transmission error.

When set to 1, the transmitted document is not printed on the transmission result table.

When set to 0, the transmitted document is printed on the transmission result table.

Default: 0 (Print transmitted documents)

Switch selection and contents of functions Initial value Remark

0

0

0

0

1

1

0

0

1

0

1

0

1

0

0

0

SW1 No.8 Inhibited to use

SW2 No.1 – No.4 Inhibited to use

SW2 No.5 – No.8 Remote selection number setup

Used to set the number by binary input for remote switch reception from an external telephone. "**" in a remote switch number (X**) is fixed.

When 10 or greater value is entered, the operations will be the same as setup of 5.

Default: Setup of 5 as 0101

SW3 No.1 – No.5 Density default setup

Used to set the default setup of density of the operation panel.

SW3 No.6 – No.8 Image quality priority selection

Used to set the initial value of image selection when scanning a document.

When set to 100, the operations are the same as the normal mode.

Default: 000 (Normal mode)

SW4 No.1 – No.4 Recall interval in communication error

Used to set recall interval after disconnection of communication due to a communication error in memory transmission.

The set range is 0 to 15 min in the increment of 1 min by binary input.

When set to 0, recall is made immediately after disconnection.

However, the time interval set by SW21 (Interval between the end of a communication and the next call) is taken.

Default: 0001 (1 min)

SW4 No.5 – No.8 Recall interval in busy

Used to set recall interval after disconnection of communication due to the busy state of the other party or no response.

Can be set in the range of 1 – 15min by increment of 1min by binary input.

When set to 0 min, it is the same as setup of 3 min.

Default: 0 0 1 1 (3 min)

SW5 No.1, No.2 Line equivalent unit [km]

Used to set the modem filter coefficient.

SW5 No.3, No.4 Inhibited to use

SW5 No.5 – No.8 Signal send level

Used to set the attenuation quantity of signal send level from the modem. The actual output level to the line pin is further attenuated by

8dBm. (When set to 2, the actual level on the line is about –10dBm.)

Default: 0 1 1 1 (–12dBm)

AR-FX4 SOFT SWITCH DESCRIPTIONS - 19

SW6 No.1 ECM

Used to set whether ECM (Error Correction Mode) is performed or not.

When, however, SW52-7 (V.34 mode function) is set to OFF, or when

SW52-7 (V.34 mode function is set to ON and the transmission is not the super G3 transmission, ECM Disable setup is effective. This is because the ECM function is indispensable in a transmission other than super G3 transmission in V.34 mode and the other party machine may perform checking. With SW52-7 (V.34 mode function) is ON and this reception function is disabled.

When set to 1, ECM is enabled.

When set to 0, ECM is disabled.

Default: 1 (ECM enabled)

SW6 No.2 CED signal send

Used to set whether CED signal is sent or not. This setup is effective only when SW52-7 (V.34 mode function) is off. This is because V.34

mode requires sending of ANSam signal.

When set to 1, CED (ANSam) signal is sent.

When set to 0, CED (ANSam) signal is not sent.

Default: 1, CED (ANSam) signal is sent.

SW6 No.3 CSI transmission

CSI signal includes the telephone number registered as sender’s number. Used to set whether this signal is sent or not.

When set to 1, CSI signal is sent.

When set to 0, CSI signal is not sent.

Default: 1 (CSI signal is sent.)

SW6 No.4 DIS reception confirmation in G3 send

Used to set whether DIS reception is checked or not in G3 mode.

When set to 1, DIS reception is always checked twice.

When set to 0, NSF/DIS reception is checked once, or DIS reception without NSF is checked twice.

Default: 0 (NSF reception is checked once, DIS without NSF is checked twice.)

SW6 No.5 Non-modulation carrier in V.29 send

Used to set whether non-modulation carriers are sent or not in V.29

transmission.

When set to 1, non-modulated carrier is sent.

When set to 0, non-modulated carrier is not sent.

Default: 0 (Non-modulated carrier is not sent.)

SW6 No.6 EOL detection timer

Used to set the detection timer of EOL (End Of Life) when Phase-C reception.

When set to 1, the timer is set to 25sec.

When set to 0, the timer is set to 13sec.

Default: 0 (13sec)

SW6 No.7 Countermeasures for echo in reception (CED tone send interval)

Used to select ON/OFF of countermeasures against echo.

An interval of 500ms is inserted before DIS transmission.

Default: 0 (75ms)

SW6 No.8 Countermeasure for echo in transmission

(After reception of DIS, hold time up to signal send is set.)

An interval of 500ms is inserted before DCS transmission.

Default: 0 (200ms)

SW7 No.1 MH fixed

Used to fix the image data compression method in communication.

Normal setting

When set to 0, automatic selection of MH/MR/MMR is performed according to the other party machine’s capacity.

When set to 1, MH fixed. This is effective when communication is made only with MH machine or when images are disturbed due to poor conditions of the line.

When SW52-7 (V.34 mode function) is OFF or when SW52-7 (V.34

mode function) is ON in transmission, MH fixing is enabled.

This is because the MMR function is indispensable in V.34 mode and the other party machine checks that. When SW52-7 (V.34 mode function) is ON in reception, this function is disabled.

SW7 No.2 Dial tone detection

Used to set whether dial tone detection is performed or not in auto dial ringing.

"1": YES

"0": NO

When set to YES and dial tone is not detected, dial is not performed.

Default: 0 (NO)

SW7 No.3 Busy tone detection

Used to set whether busy tone signal is detected or not in ringing.

When set to 1, busy tone is detected.

When set to 0, busy tone is not detected.

Default: 1 (Busy tone is detected.)

SW7 No.4 Dial tone monitoring time

Used to set dial tone monitoring time when detecting dial tone.

"1": 10sec

"0": 5sec

Default: 0 (5 sec)

SW7 No.5 Inhibited to use

SW7 No.6 Max. length of reception

Used to set the length of reception when long document is sent from the other party.

When set to 1, reception is made without limitations.

When set to 0, reception is terminated after 1.5m reception.

Default: 0 (Reception is terminated after receiving 1.5m.)

SW7 No.7, No.8 Modem speed in reception fixed

Used to set the start speed of reception procedure when receiving from an other party other than V.34.

bit 7 8

0 0 : No fixing

0 1 : V.29-9600BPS

1 0 : V.27ter-4800BPS

1 1 : V.17-14400BPS

When set to "no fixing," the operations are the same as V.17-

14400BPS.

The above four setups are possible. The reception procedure is started at the set communication speed.

Default: 0 0 (no fixing) Reception is made at the proper communication speed.

SW8 No.1 Memory transmission/direct transmission default setup

Used to select memory transmission or direct transmission when the power is turned on and when time out is cleared.

When set to 1, direct transmission is selected when the power is turned on and the time out is cleared.

When set to 0, memory transmission is selected when the power is turned on and the time out is cleared.

Default: 0 (Memory transmission)

SW8 No.2 Proxy reception

When set to 1, auto reception is accepted under the following conditions to perform proxy reception.

(1) No recording paper or jam

(2) Remaining image memory capacity is 128KB or 64KB or above.

(3) The number of memory reception (max. 50 items) and the number of pages do not exceed the limit.

When set to 0, automatic reception is not allowed without recording paper or in case of a jam.

Default: 1 (YES)

AR-FX4 SOFT SWITCH DESCRIPTIONS - 20

SW8 No.3 Printing the content of transmitted document in normal memory transmission

Used to set whether transmitted images are printed on the communication result table or not when the communication result table is printed after normal completion of memory transmission.

"1": The transmitted document is not printed.

"0": The transmitted document is printed.

Default: 1 (Not printed.)

SW8 No.4 Judgment of system No. in bulletin transmission

Used to set whether the condition of coincidence between the system number of this machine and that of the other party machine is employed as a criterion to judge whether to allow bulletin transmission by receiving polling transmission from the other party machine made by our company.

"1": When the system number of the other party machine made by our company coincide with the system number of this machine, polling is allowed.

"0": Though the system number of the other party machine made by our company coincide with the system number of this machine, polling is not allowed.

Default: 0 (Inhibited)

SW8 No.5 Remote reception indication

Used to set whether remote select function is used or not.

When set to 1, the function is allowed.

When set to 0, inhibited.

Default: 1 (Allowed)

SW8 No.6 – No.8 Inhibited to use

SW9 No.1 Print of total communication time and total pages

Used to set whether total communication time and total number of sheets are recorded or not on the communication record table.

When set to 1, the total communication time and the total number of pages are printed on the communication record table.

When set to 0, they are not printed on the communication record table.

Default: 1 (YES)

SW9 No.2 Inhibited to use

SW9 No.3 Quick memory transmission

Used to set whether quick memory transmission (transmission of ringing before completion of scanning) is performed or not. Linked with the key operator program menu.

Default: 1 (Allow)

SW9 No.4 Yes/No of SUB capacity in reception

Used to set notification of YES/NO of DIS signal Bit 49 SUB capacity.

"0": YES

"1": NO

Default: 0 (YES)

When notified 0 and NO, the F code transmission from the other party can be inhibited.

SW9 No.5 F-code relay broadcast function

Used to set whether F code relay broadcast instruction from the other party is received and relay broadcast transmission is performed or F code relay broadcast instruction is not received (though the relay box number by SUB coincides with) from the other party. Though this function is set to disable, F code instruction can be transmitted.

Default: 0 (Allow)

SW9 No.6 F-code confidential reception function

Used to set whether F code confidential reception from the other party is made or not (though the confidential box number by SUM coincides with).

Though this function is set to disable, F code transmission can be made.

Default: 0 (Allow)

SW9 No.7 Yes/No of SEP capacity in reception

Used to set notification of YES/NO of DIS signal Bit 47 SEP capacity.

"0": YES

"1": NO

Default: 0 (YES)

When set to 1 (NO), F code polling is inhibited.

SW9 No.8 Yes/No of reception PWD capacity

Used to set whether password function is judged or not for F code bulletin board polling.

"0": Password is judged. If password is not acceptable, communication is cut off.

"1": Password is not judged. Password is disregarded and communication is allowed.

Default: 0 (Password is judged.)

SW10 No.1 Measurement of communication time (image)

Used to set YES/NO of measurement.

Used to measure the communication time in phase C. However, it is the communication time in the latest phase C. (Unit: msec)

Default: 1 (YES)

SW10 No.2 Sender’s telephone number registration

Used to set Enable/Disable of registered transmitter telephone number change.

When set to 1, sender’s TEL No. cannot be registered and changed.

To prevent sender’s TEL No. from being changed erroneously, this is set to 1.

Default: 0 (Allow)

SW10 No.3 Yes/No of reception SID capacity

Used to set whether password is judged or nor in F code reception.

"0": Password is judged. If password is not acceptable, communication is cut off.

"1": Password is not judged. Password is disregarded and communication is allowed.

Default: 0 (Password is judged.)

SW10 No.4 SDT signal detection

Used to set whether SDT signal which is the second dial tone when transmitting to F net is detected or not.

When SDT signal is not detected, dialing is performed normally even after "16X."

When set to 1, the signal is detected.

When set to 0, the signal is not detected.

Default: 0 (Not detected)

SW10 No.5, No.6 Inhibited to use

SW10 No.7 ECM MMR mode

Used to set whether MMR coding system is used or not.

"1": MMR is used.

"0": MMR is not used.

Default: 1 (MMR communication is made.)

SW10 No.8 ECM JBIG mode

Used to set whether JBIG communication is used or not.

"1": JBIG communication is used.

"0": JBIG communication is not used.

Default: 1 (JBIG communication is used.)

SW11 No.1 – No.8 Inhibited to use

AR-FX4 SOFT SWITCH DESCRIPTIONS - 21

SW12 No.1 – No.5 Inhibited to use

SW12 No.6, No.7 CI detection

Used to set the frequency to detect CI signal which is the calling signal as follows: bit 6 7

0 0 : 4 sine wave (280ms)

1 0 : 3 sine wave (190ms)

0 1 : 2 sine wave (130ms)

1 1 : Similar to 4 sine wave (280mm).

Default: 0 0 (4 sine wave)

SW12 No.8 Inhibited to use

SW13 No.1 – No.6 Inhibited to use

SW13 No.7 Relay data output

Used to set whether the received document is outputted from the relay direction station when relay broadcasting direction is received.

When set to 1, the document received from the relay instruction station is printed.

When set to 0, the document received from the relay instruction station is not printed.

Default: 1 (Printed)

SW13 No.8 Relay broadcast function

Used to set whether relay broadcasting transmission is performed when receiving the relay broadcasting direction from the other party or the relay broadcasting direction is not received from the other party.

When set to 1, the relay broadcast instruction from the allowed party is received.

When set to 0, the relay broadcast instruction is not received even from the allowed party.

Default: 1 (The relay broadcast instruction is received.)

When this function is set to disable, relay broadcast instruction can be transmitted.

SW14 No.1 – No.4 V.34 mode sending speed

Used to set the transmission speed when starting communication in

V.34 mode.

Setting can be made by binary input of N in "2400 (bps) x N" in the range of 2400bps – 33600bps.

N can be set in the range of 0 – 15. When it is set to 0, 2400bps; when set to 15, 33600bps.

Default: N = 14 (Transmission is started from 33600bps.)

SW14 No.5 – No.8 V.34 mode reception speed

Used to set the reception speed when starting reception in V.34 mode.

Setting can be made by binary input of N in "2400 (bps) x N" in the range of 2400bps – 33600bps.

N can be set in the range of 0 – 15. When it is set to 0, 2400bps; when set to 15, 33600bps.

Default: N = 14 (Reception is started from 33600bps.)

SW15 No.1 Lower limit of speaker sound detection time

Lower limit of speaker sound detection time

1: 350ms 0: 250ms

Default: 0 (250ms)

SW15 No.2 Upper limit of speaker sound detection time

Upper limit of speaker sound detection time

1: 650ms 0: 750ms

Default: 0 (750ms)

SW15 No.3 Lower limit 2 of speaker sound detection time

Lower limit 2 of speaker sound detection time

1: 150ms 0: Follows SW15-1.

Default: 0 (Follows SW15-1.)

SW15 No.4 Inhibited to use

SW15 No.5 – No.8 Modem speed (V.33 mode or less)

Used to set the speed to start communication. When communication troubles occur frequently, the speed may be reduced to solve the troubles.

Default: 1 0 0 0 (V.17 14.4kbps)

SW16 No.1 Inhibited to use

SW16 No.2 External telephone connection

When this switch is not set to YES, an external telephone cannot be used.

Default: 1 (YES)

SW16 No.3, No.4 Inhibited to use

SW16 No.5 Rotation transmission selection (11 x 8.5

8.5 x 11)

Used to set whether letter R document is transmitted as A3 width or the scanned image is rotated and transmitted as A4R width.

Default: 1 (YES)

SW16 No.6 Rotation transmission selection (A4

A4R)

Used to set whether A4 document is transmitted as A4 or the scanned image is rotated and transmitted as A4R.

When set to 1, the document is transmitted as A4 width.

When set to 0, the document is transmitted as A3 width.

Default: 1 (Transmitted as A4 width.)

SW16 No.7 Rotation transmission selection (B5R

B5)

Used to set whether B5R document is transmitted as B5R or the scanned image is rotated and transmitted as B5.

When set to 1, the document is transmitted as B4 width.

When set to 0, the document is transmitted as A4 width.

Default: 1 (Transmitted as B4 width.)

SW16 No.8 Rotation transmission selection (A5

A5R)

Used to set whether A5R document is transmitted as A5R or the scanned image is rotated and transmitted as A5.

When set to 1, the document is transmitted as A4 width.

When set to 0, the document is transmitted as A5R.

(However, the transmission width is A4.)

Default: 1 (Transmitted as A4 width.)

SW17 No.1 Paper selection priority sequence

Used to set whether the FAX reception paper is selected by data width priority or data area priority.

"0": Area priority

"1": Width priority

Default: 0 (Area priority)

SW17 No.2, No.3 Output condition setup

Used to set whether the received data are reduced or divided to print when a document is received and there is no suitable size paper.

bit 2 3

0 0 : Reduction allowed

1 0 : Division allowed

Default: 0 0 (Reduction print)

SW17 No.4 – No.8 Inhibited to use

SW18 No.1, No.2 Inhibited to use

AR-FX4 SOFT SWITCH DESCRIPTIONS - 22

SW18 No.3, No.4 Reception size specification (Indicates reception capacity.)

Used to set the receivable document width which is informed the other party when receiving a communication.

The setup items are as follows: bit 3 4

0 0 : By the attached cassette

0 1 : B4 (A4/B4) width

1 0 : A4 width

1 1 : A3 (A4/B4/A3) width

Default: 0 0 (Varies depending on the installed cassette.)

Max. allowed reception width selection

Max. allowed reception width is determined by Table 1 and Table 2.

This determines the transmitted size from the other party.

When set to A3 with SW18-No. 3/No. 4 only with B5 cassette, proxy reception is always performed. Do not use this combination.

(Because division process in the main scanning direction is not performed.)

When set to A4 with SW18-No. 3/No. 4, A3 document from the other party is not divided into A4 paper but reduction to A4width is requested to the other party.

• Max. allowed reception width setup

SW18

No.3

No.4

0 0

0

1

1

1

0

1

A4

A3

Size specification

Depends on the installed cassette.

B4

Reception allowable width

Varies according to the table below.

A4 & B4 width

A4 width

A4 & B4 & A3 width

• Max. allowable reception width by installed cassette

[Max. paper size of installed

→ cassette with FAX function]

A5

B5

A4

B4

A3

No cassette with FAX function

[Sampled paper size

(Data width)]

A4

B4

A3

B4

A3

A3

SW18 No.5 11 inch reception capacity setup

When SW18-3 – 4 is set to "Depends on installed cassette," the max.

allowable reception width by 8.5 x 11" cassette is set.

When set to 0, the reception allowable width is A3.

When set to 1, the reception allowable width is B4.

Default: 0 (Reception allowable width is A3)

SW18 No.6 Output method when A3 width reception (Inch series)

Used to set whether an image of 297mm width is reduced and printed or an image of 11" width is printed without reduction on paper of 11" width when an image of A3 width is received.

When set to 0, printing is made on paper of 11" width.

When set to 1, printing is made on paper of 297mm width.

Default: 0 (Printed on paper of 11" width.)

SW18 No.7 Output method when A4 width reception (Inch series)

Used to set whether printing is made on paper of 8.5" width or of

210mm width when an image of A4 width is received.

When set to 0, printing is made on paper of 210mm width.

When set to 1, printing is made on paper of 8.5" width.

Default: 1 (Printing is made on paper of 8.5" width.)

SW18 No.8 Override print setup

Used to set whether the latter print job is performed or not when the former print job is suspended at the first page due to printable paper empty.

When set to 0, override print is not allowed.

When set to 1, override print is allowed.

Default: 1 (Override print allowed)

SW19 No.1 Protocol monitor

Used to set whether communication protocol result is printed after completion of communication or not.

Used for communication test.

Default: 0 (NO)

SW19 No.2 Inhibited to use

SW19 No.3 Output only in protocol monitor error

Used to set whether protocol monitor is outputted only when a communication error occurs or every time when communication is completed.

Effective when SW19 No. 1 (Protocol monitor) is set to YES. However, only when SW19 No. 1 is set to 1 (YES), protocol monitor is outputted in case of a communication error.

Default: 0 (NO)

SW19 No.4 Protocol monitor save

Used to set whether the protocol monitor of the final communication is saved or not.

When set to "Saved," the preceding protocol monitor can be printed with SIM 66-21.

Default: The protocol monitor is saved.

SW19 No.5 Inhibited to use

SW19 No.6 Recording table automatic print

Used to set whether the communication record table is printed automatically when each of transmission/reception data of communication record table reaches 50 items.

When set to 1, the table is automatically printed.

When set to 0, the table is not printed though the data reaches 50 items.

Default: 1 (Printed)

SW19 No.7 Time specification 1 of communication record table

Used to set whether time No. 1 is enabled or not in the output function of communication result table at the specified time.

Linked with the key operator program.

Default: 0 (Inhibit)

SW19 No.8 Time specification 2 of communication record table

Used to set whether time No. 2 is enabled or not in the output function of communication result table at the specified time.

Linked with the key operator program.

Default: 0 (Inhibit)

SW20 No.1, No.2 Line sound monitor range

Used to set the line sound monitor range when the line monitor function is used.

Used to set to monitor NSF signal send/receive until NSF signal is sent/received.

When set to ALL, all procedures up to line disconnection are monitored.

The setup items are as follows: bit 1 2

0 0 : Not used. (Same as 0.1)

0 1 : Up to NSF signal send/receive

1 0 : All

1 1 : Not used. (Same as 0.1)

Default: 0 1 (Up to NSF signal send/receive)

AR-FX4 SOFT SWITCH DESCRIPTIONS - 23

SW20 No.3 Line monitor display

Used to set whether the communication speed and the reception level are displayed on the LCD or not.

Displayed on the communication status screen by pressing the job status key.

When set to 1, displayed on LCD.

When set to 0, not displayed on LCD.

Default: 0 (Not displayed)

SW20 No.4 Data output specification in communication error during reception

Used to set whether the image on the page where a communication error occurred during image reception is printed or not.

"0": Setup to print

"1": Setup not to print

Default: 0 (Output)

However, “Output setting” is effective only when SW24-6 is set to "Output for every page reception."

SW20 No.5 Receivable memory capacity

Used to set the remaining memory capacity for acceptance of call.

When set to 1, ringing is made until the remaining memory capacity is

64KB or less.

When set to 0, ringing is made until the remaining memory capacity is

128KB or less.

Default: 0 (Ringing is made until the remaining is 128KB or less.)

SW20 No.6 Memory over during reception

Used to set whether the received data are output or destroyed when memory is over during reception.

When set to 1, received data are output.

When set to 0, received data are disposed without output.

Default: 1 (Received data are output)

SW20 No.7, No.8 Flag-adrs timer setup (V.21-FSK)

Used to set the time between Flag-adrs during FSk signal reception in a communication other than V.34 mode.

FSK signal reception in V.34 does not conform to this soft switch.

Default: 0 0 (6sec)

SW21 No.1 – No.8 Inhibited to use

Used to set the time interval between the end of a communication and a call for the next communication.

The actual interval is the setup value + 3.5sec.

Setup is made by binary input in the interval of 0 – 255sec.

The initial setup is to ring in the interval of 1sec.

SW22 No.1 – No.8 Inhibited to use

SW23 No.1 – No.8 Inhibited to use

SW24 No.1, No.2 Image capacity at send request

Used to set the image capacity of the machine when send request

(polling).

Reflected on DTC.

Default: 0 0 (Ultra fine)

SW24 No.3 Specified number reception

Used to set ON/OFF of the function to reject FAX reception from a registered number.

Default: 0 (Ignore specified number reception)

SW24 No.4 Specified number reception when manual reception

Used to set whether reception from manual reception is rejected or not when reception function by specifying the number is ON.

Default: 0 (Ignore specified number reception)

SW24 No.5 Inhibited to use

SW24 No.6 Document output setup in reception

Used to set whether all received documents are outputted at a time after completion of reception or each document is outputted every time when it is received.

When set to 1, all are outputted collectively after completion of reception.

When set to 0, output is made after reception of every page.

Default: 0 (Output after reception of every page)

SW24 No.7 Inhibited to use

SW24 No.8 Automatic reduction print

Used to set whether the received document is automatically reduced and printed so that the print-out is fit in a fixed size when the document size is longer than the fixed sizes but smaller than the max. length of automatic reduction ratio.

When set to 1, the document is automatically reduced and printed.

When set to 0, the document is printed without reduction.

Default: 1 (Automatic reduction print enable)

SW25 No.1 – No.4 Automatic reduction rate setup

Used to set the auto reduction ratio when "Auto reduction print" is set to Enable.

Setup is made in the range of 0 – 15% by binary input of N in "100% –

N x 1%."

Default: 94% (Reduce 6%)

SW25 No.5 – No.8 Inhibited to use

SW26 No.1 – No.8 Inhibited to use

SW27 No.1 Inhibited to use

SW27 No.2 – No.5 Recording paper tray selection

(Tray 1 – 4)

Used to select the tray for output of the received documents.

Tray 1 to Tray 4 can be set to ON/OFF individually. When set to OFF, the tray does not output received documents.

Setup is made by selecting bit 2 – bit 5. Each bit is selected in the sequence of tray 1 – tray 4.

When bit 1 is selected, output is made by using that tray.

When bit 0 is selected, output is made by using that tray.

Default: Tray 1 – tray 4 are used.

bit bit bit bit

4

5

2

3

: Tray 1

: Tray 2

: Tray 3

: Tray 4

SW27 No.6 – No.8 Inhibited to use

SW28 No.1 – No.8 Inhibited to use

SW29 No.1 – No.4 Inhibited to use

SW29 No.5 – No.8 Setup of number of times of call rings

Used to set the number of call rings until reception is started in auto reception mode.

The set range is 0 to 9 times by binary input.

When set to 0, no ring is made.

Default: 2 times

SW30 No.1 Report output when canceling

Used to set whether the communication report table is outputted or not when canceling transmission during document transmission.

When set to 1, the communication report table is printed.

When set to 0, the communication report table is not printed.

Default: 0 (Not printed)

SW30 No.2 Inhibited to use

AR-FX4 SOFT SWITCH DESCRIPTIONS - 24

SW30 No.3 Rotation print

Used to set Enable/Disable of rotation print when the received document can be printed by rotation.

When set to 1, the received document is rotated and printed.

When set to 0, the received document is not rotated.

Default: 1 (The received document is rotated and printed.)

SW30 No.4 Department management

Used to set Enable/Disable of FAX using dept. management by the use of the dept. management function.

When set to 1, the department management function is used.

When set to 0, the department management function is not used.

Default: 0 (The department management function is not used.)

SW30 No.5 Default data, sender print

Used to set whether the registered sender information and date and time of transmission are printed at the top of the transmission document when a document is transmitted through the second line.

When set to 1, date and sender are printed.

When set to 0, date and sender are not printed.

Default: 1 (Date and sender are printed.)

SW30 No.6 Department name notification

Used to set whether the department name is transmitted as sender information when the department management function is enabled.

Default: 0 (OFF)

SW30 No.7 Date/sender print position setup

Used to set the print position of date and transmitter information on the transmitted documents.

When set to 1, printed at the top of the document.

When set to 0, added outside the document.

Default: 0 (Added outside the document.)

SW30 No.8 Report output (in confidential reception)

Used to set whether the communication report table is outputted or not when a confidential reception is made.

When set to 1, the communication report table is printed.

When set to 0, the communication report table is not printed.

Default: 1 (Printed)

SW31 No.1, No.2 Report output (in transmission)

Used to set whether the communication report is outputted or not after completion of transmission (excluding sequential broadcasting, sequential send request, and relay broadcasting).

Setup is selected from "print inhibition," "all output," and "only when transmission is failed" as follows: bit 1 2

0 0 : Print inhibited

0 1 : All are printed.

1 0 : Only when transmission is failed.

1 1 : Not used (Same as "Only when transmission is failed.")

Default: 1 0 (Outputted only when transmission is failed.)

SW31 No.3, No.4 Report output (In broadcast, sequential send request, and relay broadcast)

Used to set whether the communication report table is outputted or not after completion of transmission (sequential broadcasting, sequential send request, and relay broadcasting).

Setup is selected from "print inhibition," "all output," and "only the address to which transmission is failed" as follows: bit 3 4

0 0 : Print inhibited

0 1 : All are printed.

1 0 : Only the address to which transmission is failed.

1 1 : Not used (Same as "Only the address to which transmission is failed")

Default: 0 1 (All are printed.)

SW31 No. 5, No.6 Report output (in reception)

Used to set whether the communication report table is outputted or not when a reception (excluding confidential reception) is made.

Setup is selected from "print inhibition," "all output," and "only in error" as follows: bit 5 6

0 0 : Print inhibited

0 1 : All are printed.

1 0 : Only in error

1 1 : Same as "print inhibited."

Default: 0 0 (Print inhibited)

SW31 No.7, No.8 Inhibited to use

SW32 No.1 – No.4 Distinctive ring

The function judges TEL or FAX by CI ringing.

Default: 0 0 0 0 (OFF)

SW32 No.5 Inhibited to use

SW32 No.6 Index print setup

Used to set whether the index is printed or not when outputting received documents.

When set to 1, the index is printed on the received document.

When set to 0, the index is not printed.

Default: 0 (The index is not printed.)

SW32 No.7, No.8 Inhibited to use

SW33 No.1 Page number print setup

Used to set whether the page number is added to the position where date and transmitter information are printed. (In memory transmission, paper number/total number of pages)

When set to 1, the page number is printed.

When set to 0, the page number is not printed.

Default: 1 (The page number is printed.)

SW33 No.2 – No.8 Inhibited to use

SW34 No.1 – No.8 Inhibited to use

SW35 No.1 Cover function default setup

Used to set whether the cover is added or not when transmitting.

When set to 1, the cover is added.

When set to 0, the cover is not added.

Default: 0 (The cover is not added.)

SW35 No.2 Inhibited to use

SW35 No.3, No.4 CI delete max. OFF time

Used to set the max. wait time from detection of CI signal pulse (number of times) to the next CI signal pulse detection. If next Ci signal pulse is not detected within this time, the number of calls up to now is cleared.

The setup items are as follows: bit 3 4

0 0 : 5sec

0 1 : 10sec

1 0 : 15sec

1 1 : 20sec

Default: 0 1 (10sec)

SW35 No.5 – No.8 Inhibited to use

SW36 No.1 – No.8 Inhibited to use

SW37 No.1 – No.8 Inhibited to use

SW38 No.1 – No.4 Pause time setup

Used to set the pause time.

The set range is 1 sec to 15 sec by binary input.

When set to 0, it is the same as 2 sec.

Default: 2sec

AR-FX4 SOFT SWITCH DESCRIPTIONS - 25

SW38 No.5, No.6 Inhibited to use

SW38 No.7 Transfer function

Used to set Enable/Disable the transfer function.

Default: 0 (Inhibit)

SW38 No.8 Inhibited to use

SW39 No.1 – No.3 Call time setup in automatic transmission (T0 timer setup)

Used to set the call time when call does not reach the other party in auto send mode.

The set range is 30 to 60 sec in the increment of 5 sec by binary input of "(5 sec x N) + 30 sec)".

"N" can be set in the range of 0 to 7. When set to 7 (65 sec), it is the same as setup of 45 sec.

Default: 45sec (N=3)

SW39 No.4 – No.8 Inhibited to use

SW40 No.1 – No.4 Number of times of recall in error

Used to set the number of recall times in case of a communication error.

Setup is made in the range of 0 – 1 times by binary input.

When set to 0, recall is not made.

Default: 1 time of recall

SW40 No.5 – No.8 Number of times of recall in busy

Used to set the number of recall times in case of busy state of the other party or when call does not reach the other party.

Setup is made in the range of 0 – 14 times by binary input.

When set to 0, recall is not made.

Default: 2 times of recall

SW41 No.1, No.2 Tone/Pulse default setup

Employed line setup (Dial setup)

Selection of 10PPS, 20PPS, and TONE is allowed.

The setup items are as follows: bit 1 2

0 0 : 10PPS

0 1 : 20PPS

1 0 : TONE

1 1 : Similar to TONE.

Default: 1 0 (TONE)

SW41 No.3 Telephone line menu

Used to set whether Tone/Pulse setup is displayed on the menu or not.

Default: 0 (Fixed to “Allow”)

SW41 No.4 Maintenance system

Setup of the model for judgment of consumable parts system when using the F.A.S.T. function.

SW41 No.5 F.A.S.T mode

Used to set Enable/Disable of FAST operation.

To enable FAST operation, the serviceman must change this SW setup.

Default: 0 (NO)

SW41 No.6, No.7 Sequence of year/month/day in LCD, report, and sender record

Used to set the sequence of year, month, and day in the display, report, and sender record.

SW41 No.8 Time display format

Used to set the sequence of year, month, and day in the LCD display, report, and sender record.

When set to 0, time is indicated in 24H format.

When set to 1, time is indicated in AM/PM format.

Default: 1 (AM/PM)

SW42 No.1 Direct send recall Allow/Inhibit

Used to set allow/inhibit of wait for recall in direct send.

Default: 1 (Allow)

SW42 No.2, No.3 Inhibited to use

SW42 No.4 Manual/Auto reception auto swiching

Used to set whether automatic reception is made or not when ringing is made the number of auto switch call times in manual reception.

Default: 0 (Inhibit)

SW42 No.5 – No.8 Number of auto switch calls of manual reception

auto reception

When the above setup is allowed, automatic reception is made at the set number of times.

The set range is 1 to 9 times.

Default: 9 times

SW43 No.1 – No.5 DTMF signal send time

Used to set the send time when sending DTMF signal.

Setup is made in the range of 60 – 310ms by binary input of N in

"10(ms) x N" in the increment of 10ms.

N is set in the range of 0 – 31.

When N is set to 0, it is the same as 110ms (N=11).

Default: 110ms

SW43 No.6 – No.8 Maintenance cycle

Setup for judgment of consumable parts notification when using the

F.A.S.T. function. This setup should be the same as SIM21-2 setup.

Default: 0 0 1 (50K)

SW44 No.1 – No.4 Scan effective image area (OC) Main scan Left edge image loss

Used to set the left edge image loss of main scan in OC scan of FAX.

The set value of SIM 50-8 is reflected.

SW44 No.5 – No.8 Scan effective image area (SPF) Main scan Left edge image loss

Used to set the left edge image loss of main scan in SPF scan of FAX.

The set value of SIM 50-8 is reflected.

SW45 No.1 – No.4 Scan effective image area (OC) Main scan Right edge image loss

Used to set the right edge image loss of main scan in OC scan of FAX.

The set value of SIM 50-8 is reflected.

SW45 No.5 – No.8 Scan effective image area (SPF) Main scan Right edge image loss

Used to set the right edge image loss of main scan in SPF scan of

FAX.

The set value of SIM 50-8 is reflected.

SW46 No.1, No.2 Inhibited to use

SW46 No.3 Priority in the day of week

Used to set the recording sequence of the day of month and the day of week if the date is in the sequence of day, month, and year.

Default: 0 (NO)

SW46 No.4 Inhibited to use

SW46 No.5 Daylight saving tive

Used to set Enable/Disable of Daylight saving time.

Default: 0 (Inhibit)

SW46 No.6 – No.8 Inhibited to use

SW47 No.1 – No.5 Time specification print 1 (O’clock) in the communication report table

Used to set "o’clock" of the time (o’clock, min) when specifying the time in the communication report table.

Setup is in the range of 0 – 23 (o’clock) by binary input.

When set to 24 – 31, the time is set to 0 o’clock.

Default: 0 o’clock

AR-FX4 SOFT SWITCH DESCRIPTIONS - 26

SW47 No.6 – No.8 Inhibited to use

SW48 No.1 – No.6 Time specification print 1 (min) in the communication report table

Used to set "min" of the time (o’clock, min) when specifying the time in the communication report table.

Setup is in the range of 0 – 59 (min) by binary input.

When set to 60 – 63, the time is set to 0 min.

Default: 0 min

SW48 No.7, No.8 Inhibited to use

SW49 No.1 – No.5 Time specification print 2 (O’clock) in the communication report table

Used to set "o’clock" of the time (o’clock, min) when specifying the time in the communication report table.

Setup is in the range of 0 – 23 (o’clock) by binary input.

When set to 24 – 31, the time is set to 0 o’clock.

Default: 0 o’clock

SW49 No.6 – No.8 Inhibited to use

SW50 No.1 – No.6 Time specification print 2 (min) in the communication report table

Used to set "min" of the time (o’clock, min) when specifying the time in the communication report table.

Setup is in the range of 0 – 59 (min) by binary input.

When set to 60 – 63, the time is set to 0 min.

Default: 0 min

SW50 No.7, No.8 Inhibited to use

SW51 No.1 – No.5 Inhibited to use

SW51 No.6 CED detection time

Used to set CED/ANSam signal detection time. When the CED/

ANSam signal is detected for duration of the set time, it is recognized.

When set to 1, if a signal is detected for 500ms or more, it is recognized.

When set to 0, if a signal is detected for 1000ms or more, it is recognized.

Default: 0 (1000ms or more)

SW51 No.7, No.8 Busy tone detection cycle

Used to set the number of pulses of busy tone detected to recognize as busy tone.

When set to 0 0, 2 pulses are detected.

When set to 0 1, 4 pulses are detected.

When set to 1 0, 6 pulses are detected.

When set to 1 1, 10 pulses are detected.

Default: 0 0 (2 pulses are detected for recognition of busy tone.)

SW52 No.1, No.2 Busy tone detection level

Used to set the lowest detection level when detecting busy tone.

When set to 0 0, busy tone of –43dB is detected.

When set to 0 1, busy tone of –35dB is detected.

When set to 1 0, busy tone of –33dB is detected.

When set to 1 1, busy tone of –30dB is detected.

Used to set for erroneous detection of busy tone.

Default is 0 0 (–43dB).

SW52 No.3 ERR frame reception operation

Used to set the operation when image data with error frame is received.

"0": Not continue process. (Error)

"1": Continues process.

Default: 0 (Not continue process. (Error))

SW52 No.4 Inhibited to use

SW52 No.5 Error process in RTN reception

Used to set whether RTN reception is treated as a communication error or not.

When set to 1, it is not judged as an error when RTN is received.

When set to 0, it is judged as an error when RTN is received.

Default: 0 (Judged as an error.)

SW52 No.6 V.34 mode function in manual communication

Used to set whether V.34 mode function is enabled or not in manual transmission.

When set to 1, V.34 mode function is enabled.

When set to 0, V.34 mode function is disabled.

Default: 1 (V.34 mode function is enabled.)

SW52 No.7 V.34 mode function

Used to set whether V.34 mode is used for send/receive with the other party machine is provided with V.34 mode.

When set to 1, send/receive is made by using V.34 mode.

When set to 0, send/receive is made without using V.34 mode.

Default: 1 (V.34 mode function is enabled.)

SW52 No.8 V.34 control channel communication speed

Used to set V.34 mode communication speed of the control channel.

When set to 1, the communication speed of control channel is

2400bps.

When set to 0, the communication speed of control channel is

1200bps.

Default: 0 (1200bps)

SW53 No.1 – No.4 DTMF send level (High group) setup

Used to set the DTMF signal send level (high group).

The set range is 0 to 7.5 with binary input in the increment of 0.5dB.

Default: 3.5

Send level = – (set value + 12)/2 [dB]

SW53 No.5 – No.8 DTMF send level (Low group) setup

Used to set the DTMF signal send level (low group).

The set range is 0 to 7.5 with binary input in the increment of 0.5dB.

Default: 3.5

Send level = – (set value + 12)/2 [dB]

SW54 No.1 – No.4 Scan effective image area (OC) Sub scan lead edge image loss

Setup of image loss in OC scan image area

The quantity of image loss at the lead edge in sub scan direction can be adjusted. When the set value is increased, the lead edge image loss quantity is increased.

The set value of SIM 50-8 is reflected.

SW54 No.5 – No.8 Scan effective image area (SPF) Sub scan lead edge image loss

Used to set image loss in SPF scan image area.

The quantity of image loss at the lead edge in sub scan direction can be adjusted. When the set value is increased, the lead edge image loss quantity is increased.

The set value of SIM 50-8 is reflected.

SW55 No.1 – No.7 CI signal OFF detection enable time

Used to set the min. OFF time for judgment of CI pulse (16Hz call signal). When OFF time continues for more than the set time, it is judged as 1 pulse of CI.

Setup is made in the range of 0 – 1270 by binary input. Set value x

10ms.

Default is 1200ms.

AR-FX4 SOFT SWITCH DESCRIPTIONS - 27

SW55 No.8 EQM judgment threshold value

Used to set whether the threshold value, FTT, for EQM judgment is severely adjusted or loosely adjusted when confirming TCF reception.

When it is loosely adjusted, TCF is easy to return CFR, however, it is apt to cause an error in PIX (Phase-C).

SW56 No.1 – No.8 Inhibited to use

SW57 No.1 – No.8 Inhibited to use

SW58 No.1 V.34 3429 (baud) Rate Mask

Used to set whether 3429 is supported as the symbol rate in V.34 communication or not.

SW58 No.2 V.34 3200 (baud) Rate Mask

Used to set whether 3200 is supported as the symbol rate in V.34 communication or not.

SW58 No.3 V.34 3000 (baud) Rate Mask

Used to set whether 3000 is supported as the symbol rate in V.34 communication or not.

SW58 No.4 V.34 2800 (baud) Rate Mask

Used to set whether 2800 is supported as the symbol rate in V.34 communication or not.

SW58 No.5 Inhibited to use

SW58 No.6 V.34 2400 (baud) Rate Mask

Used to set whether 2400 is supported as the symbol rate in V.34 communication or not.

SW58 No.7, No.8 Inhibited to use

SW59 No.1 – No.8 Inhibited to use

SW60 No.1 – No.4 Inhibited to use

SW60 No.5 Countermeasures against V.34 communication error (reception) (Phase 2 error retry setup)

Improves and controls error retry in phase 2 of V.34 reception.

Default: 0 (NO)

SW60 No.6 Countermeasures against V.34 communication error (transmission) (Phase 2 error retry setup)

Improves and controls error retry in phase 2 of V.34 transmission.

Default: 0 (NO)

SW60 No.7, No.8 Inhibited to use

SW61 No.1 – No.8 Inhibited to use

SW62 No.1 – No.8 Inhibited to use

SW63 No.1 – No.8 Inhibited to use

SW64 No.1 – No.8 Inhibited to use

SW65 No.1 – No.8 Inhibited to use

SW66 No.1 – No.8 Inhibited to use

SW67 No.1 – No.4 Setup of make rate (10PPS)

Used to set the make rate when dialing at 10PPS.

The set range of N is 0 to 15 in binary input for the make rate of (N +26 ms), which ranges from 26 to 41 ms.

Default: 40 ms

SW67 No.5 – No.8 Inhibited to use

SW68 No.1 – No.4 Inhibited to use

SW68 No.5 – No.8 T1 timer setup

Used to set time-out time from phase B to detection of signal.

T1 time-out time is set in the range of 30 – 105sec (in the increment of

5sec).

Default is 40sec.

SW69 No.1 – No.8 Inhibited to use

SW70 No.1 – No.8 Inhibited to use

SW71 No.1, No.2 Dial ringing wait time

Used to set wait time from connection of the line to start of dial ringing.

When ringing is made without detecting dial tone, ringing is made after setting this time.

When set to 0 0, ringing is made after 3.5sec.

When set to 0 1, ringing is made after 4sec.

When set to 1 0, ringing is made after 5sec.

When set to 1 1, ringing is made after 6sec.

Default: 0 0 (Ringing after 3.5sec)

SW71 No.3 – No.6 Inhibited to use

SW71 No.7, No.8 Silent detection level

Used to set the judgment level of silence.

When set to 0 0, –43dBm or less is judged as silence.

When set to 0 1, –40dBm or less is judged as silence.

When set to 1 0, –39dBm or less is judged as silence.

Default: 0 0 (–43dBm or less is judged as silence.)

SW72 No.1 EYE-Q check

Used to set whether TCF is checked or not in TCF reception.

When set to 1, check is made only with EQM value. Therefore, TCF check becomes loose.

When set to 0, check is made both with received data and EQM value.

Default: 0 (check is made both with received data and EQM value. )

SW72 No.2 – No.8 Inhibited to use

SW73 No.1 – No.6 Inhibited to use

SW73 No.7, No.8 DIS reception process selection in reception

Used to set the process when DIS is received.

When set to 0 0, it is judged as reception of echo and the command is sent again.

When set to 0 1, the line is disconnected as improper DIS.

When set to 1 0, if DIS is the receiver machine and there are some accumulated documents, bulletin transmission is made. In other cases, it is judged as reception of echo and the command is sent again.

When set to 1 1, if DIS is the receiver machine and there are some accumulated documents, bulletin board is transmitted. If DIS is the transmitter machine, it is judged as reception of echo and the command is sent again. In the other cases, it is judged as improper DIS and the line is disconnected.

Default: 0 0 (Judged as reception of echo, and the command is sent again.)

SW74 No.1 – No.4 Print lead edge adjustment (Lead edge adjustment)

Setup of print image area void

The quantity of lead edge void in sub scan direction can be adjusted.

When the set value is increased, the lead edge void is increased.

Setup of SIM 50-9 is reflected.

SW74 No.5 – No.8 Print lead edge adjustment (Rear edge adjustment)

Setup of print image area void

The quantity of lead edge void in sub scan direction can be adjusted.

When the set value is increased, the lead edge void is increased.

Setup of SIM 50-9 is reflected.

AR-FX4 SOFT SWITCH DESCRIPTIONS - 28

SW75 No.1, No.2 Transmission end sound (Buzzer sound length) setup

Setup of the length of buzzer sound indicating the completion of transmission.

Setup is selected from 3sec, 1sec, and silent as follows: bit 1 2

0 0 : 3sec

0 1 : 1sec

1 0 : Silent

1 1 : Similar to the setup of 3sec.

Default: 0 0 (3sec)

SW75 No.3, No.4 Reception end sound (Buzzer sound length) setup

Setup of the length of buzzer sound indicating the completion of transmission.

Setup is selected from 3sec, 1sec, and silent as follows: bit 3 4

0 0 : 3sec

0 1 : 1sec

1 0 : Silent

1 1 : Similar to the setup of 3sec.

Default: 0 0 (3sec)

SW75 No.5 – No.8 Print lead edge adjustment (Left edge)

Setup of print image area void

The quantity of left edge void in main scan direction can be adjusted.

When the set value is increased, the image void becomes greater.

Setup of SIM 50-9 is reflected.

SW76 No.1 – No.8 Scan magnification ratio adjustment

OC (main scan)

The magnification ratio in main scan direction of OC scan is adjusted.

Setup of SIM 48-8 is reflected.

SW77 No.1 – No.8 Scan magnification ratio adjustment

OC (sub scan)

The magnification ratio in sub scan direction of OC scan is adjusted.

Setup of SIM 48-8 is reflected.

SW78 No.1 – No.8 Print magnification ration adjustment

(main scan)

The magnification ratio in main scan direction when printing is adjusted.

Setup of SIM 48-9 is reflected.

SW79 No.1 – No.8 Print magnification ration adjustment

(sub scan)

The magnification ratio in sub scan direction when printing is adjusted.

Setup of SIM 48-9 is reflected.

SW80 No.1 – No.4 Scan effective image area (OC) Sub scan Rear edge image loss

Setup of image loss in OC scan image area

The quantity of image loss at the rear edge in sub scan direction can be adjusted. When the set value is increased, the image loss quantity at the rear edge is increased.

The set value of SIM 50-8 is reflected.

SW80 No.5 – No.8 Scan effective image area (SPF) Sub scan Rear edge image loss

Used to set image loss in SPF scan image area.

The quantity of image loss at the rear edge in sub scan direction can be adjusted. When the set value is increased, the image loss quantity at the rear edge is increased.

The set value of SIM 50-8 is reflected.

SW81 No.1 – No.4 Destination information

Destination setup

AR-FX4 SOFT SWITCH DESCRIPTIONS - 29

SW81 No.5 – No.8 Language information

Language setup

SW82 No.1 – No.8 Scan magnification ratio adjustment

SPF (main scan)

SPF scan main scan magnification ratio setup

Setup of SIM 48-8 is reflected.

SW83 No.1 – No.8 Scan magnification ratio adjustment

SPF (sub scan)

SPF scan sub scan magnification ratio setup

Setup of SIM 48-8 is reflected.

SW84 No.1, No.2 On-hook speaker volume

The speaker volume is set when on-hook.

SW84 No.3 – No.8 On-hook pattern number

Pattern of sound volume (Large/Medium/Small) when on-hook.

Refer to SIM 66-37.

SW85 No.1, No.2 Line monitor speaker volume

Used to set the line sound volume from the speaker in FAX transmission.

SW85 No.3 – No.8 Line monitor pattern number

Pattern of line monitor sound volume (Large/Medium/Small)

SW86 No.1, No.2 Ringing volume

Used to set the ringing sound volume.

SW86 No.3 – No.8 Ringing pattern number

Pattern of ringing sound volume (Large/Medium/Small)

SW87 No.1, No.2 Speaker volume in DTFM send

Used to set the volume of transmission sound and DTMF sound from speaker when pressing on-hook button.

SW87 No.3 – No.8 Pattern number in DTFM send

Pattern of sound volume (Large/Medium/Small) when sending DTMF

SW88 No.1, No.2 Speaker volume at scanner scan end

Used to set the volume of scan end sound from the speaker when scan is completed.

SW88 No.3 – No.8 Pattern number in scanner scanning

Pattern of sound volume (Large/Medium/Small) when scan is completed.

SW89 No.1, No.2 Speaker volume of communication end sound

Used to set the volume of communication end sound from the speaker when communication is completed.

SW89 No.3 – No.8 Pattern number of communication end sound

Pattern of sound volume (Large/Medium/Small) of communication end

SW90 No.1 – No.8 Inhibited to use

SW91 No.1 – No.8 Inhibited to use

SW92 No.1 – No.8 Inhibited to use

SW93 No.1 – No.8 Inhibited to use

SW94 No.1 – No.8 Inhibited to use

SW95 No.1 – No.8 Inhibited to use

SW96 No.1 – No.8 Inhibited to use

SW97 No.1 – No.8 Inhibited to use

[7] KEY OPERATOR PROGRAM

1. List

Function setup

List output, setup

Initial setup

Send function setup

Program name

No

Soft SW setup

Program function (Outline)

List output

Communication result table print

SW30-8

SW31-1 – 8

Key operator list, confidential ID list, reception rejection number list, F code setup check list, department code table, and department management record table are printed.

This setup is made to print the communication result (normal completion or communication error) after completion of communication (normal transmission, broadcasting, reception, confidential reception).

This setup is made to print data (which were tried to be sent) under the result table in case of a communication error.

The content of document is printed in case of a communication error.

Recording table print

Dial ring signal setup

Pause time

Sender registration

Sound volume

Send image quality, density

Automatic reduction transmission

Rotation transmission

SW1-7

SW47-1 – 5

SW48-1 – 6

SW49-1 – 5

SW50-1 – 6

SW19-7, 8

SW41-1, 2

This setup is made to print all the previous communication data at the specified time.

SW38-1 – 4 Used to set the pause time between destination numbers.

SW10-2 Used to register the telephone number and the sender’s name to use this machine.

SW84-1, 2

SW85-1, 2

SW86-1, 2

SW16-2

Used to set the kind of telephone line connected to this machine.

Used to set when on-hook volume, ringing volume, and line monitor volume are adjusted.

Used to set connection of external telephone.

External telephone connection

Remote switch number

Department management

Department number

Date, time

Distinctive ring

Daylight saving tive

Page number print

Default transmission setup

Quick online

Date/sender print position

Department name notification

SW2-1 – 8

SW8-5

SW30-4

No Used to register department codes and department names in department management.

Used to set date and time of the clock built in the machine.

No

SW32-1 – 4 The function judges TEL or FAX by CI ringing.

SW46-5 Used to set Enable/Disable of Daylight saving time.

SW3-1 – 5

SW1-6

Used to set when remote switch number is changed in order to enter FAX reception mode from external telephone mode.

Used to set department management.

SW16-5, 6

SW33-1

SW8-1

Used to set image quality and density under the standard state of FAX mode.

Used to set to reduce document images according to the recording paper size of the other party.

Used to set whether document placed longitudinally is transmitted laterally or transmitted by rotating reversely. (Rotation transmission setup is available for letter size, not available for B5R/A5R.)

Used to set to print page number on the top of paper in the other party.

SW9-3

SW30-7

SW30-6

Used to set the transmission mode under the standard state to memory send or direct send.

Used to set memory send or quick online send when transmission mode is memory send.

Used to set print position of date and sender at the top of recording paper of the other party.

Used to set whether document placed longitudinally is transmitted laterally or transmitted by rotating reversely.

Recall when the other party is busy.

Recall in case of a transmission error

SW4-5 – 8

SW40-5 – 8

SW4-1 – 4

SW40-1 – 4

Used to set the recall interval and the number of times of recalls when the line is busy.

Used to set resend interval and the number of times of resending when a communication error occurs during transmission.

Call time in automatic send SW39-1 – 3 Used to set the time up to disconnection of line when the other party does not respond to calling made by automatic dialing of registered number in this machine.

Cover function default setup SW35-1 Used to set whether the cover is added or not when transmitting.

AR-FX4 KEY OPERATOR PROGRAM - 1

Function setup

Reception function setup

Special function setup

Program name

Number of times of automatic reception call

Reception data print tray

Reception data print condition

Automatic reduction print in a fixed size

Reception data transfer

Soft SW setup

Program function (Outline)

SW29-5 – 8 Used to set the number of times of calls until reception is started in automatic reception state.

SW27-2 – 5 Used to set recording paper tray for printing reception data]

SW17-2 – 3 Used to set whether reduction print is made or divided print is made when there is

SW24-8 no paper of the same size as the received image.

Used to set whether reduction print is made or not according to the size of paper set in the tray when data of greater size than the size of paper set in the tray.

SW38-7

No

Used to set data transfer to the telephone number registered in this program when image data received in the memory of this machine cannot be outputted.

The FAX number to be transferred is registered.

Registration of telephone number to transfer reception data

Index print

Reception data override

SW32-6

SW18-8

Output method when A3 width reception (Inch series)

Specified number reception

Polling protection

SW18-6

SW24-3

SW1-5

No

Used to set whether a black mark (index) is printed at the top of recording paper.

Used to set to print the latter data prior to the former data when printing of the former data is in standby state due to recording paper empty, etc. and the latter data are ready to print.

Used to set whether an image of 297mm width is reduced and printed or an image of 11" width is printed without reduction on paper of 11" width when an image of

A3 width is received.

Used to set ON/OFF of the function to reject FAX reception from a registered number.

Used to set the protection function when transmission is made by receiving polling.

Used to register or delete the other party’s number for transmission by polling.

Registration of polling allow number

ID number registration

System number registration

Relay ID code registration

Confidential box registration

No

No

SW13-8

No

Used to set the system number of the other party’s machine.

Used to set for registration of the system number of this machine.

Used to set for registration of the relay broadcast transmission allow number from the transmission station.

Used to set for registration of the confidential box number and password of confidential reception.

Used to set for registration of memory box for F code confidential reception.

F code confidential box registration

Registration of F code relay group

Registration of F code bulletin board

No

No

No

Used to set for registration of memory box for F code relay reception.

Used to set for registration of memory box for F code bulletin board transmission.

2. Operating procedure

The key operator program can be set from all the modes (copy, FAX, printer, scanner). When setup is completed, the mode returns to the original mode.

Note:

• When the key operator program is used, send/receive of FAX cannot be made.

• The key operator program cannot be used during send/receive of

FAX or during communication.

A. Common procedures

1) Press [SPECIAL FUNCTION] key.

SPECIAL FUNCTION

2) Select the key operator program with [UP] [DOWN] keys, and press [OK] key.

BACK

SPECIAL FUNCTION

CONFIGURATION

PAPER SIZE SET

DISPLAY CONTRAST

KEY OPERATOR PRG.

SPECIAL FUNCT

3) Enter the key operator code.

• Enter a code of 5 digits and go to step 4).

• When a code is entered, "-" is changed to "*."

• When an erroneous key is pressed, press [CLEAR] key and enter the correct entry again.

AR-FX4 KEY OPERATOR PROGRAM - 2

4) Select FAX with [UP] [DOWN] keys, and press [OK] key.

• Select COPY, and the key operator program in the copy mode can be set.

BACK

SPECIAL FUNCTI

5) Perform setup of each program according to the description in the following pages.

• Set and register the program for setup of the following functions.

List output/setup, initial setup, transmission function setup, reception function setup, special function setup

6) When setup is completed, press [CA] (Clear All) key.

• Terminate the key operator program.

Press [BACK] key to return to the previous screen.

To terminate each program, press [CA] (Clear All) key.

B. List output

1) Perform common operating procedures up to step 4).

2) Select "List output/Setup" with [UP] [DOWN] keys and press [OK] key.

3) Select "List output" with [UP] [DOWN] keys and press [OK] key.

4) Select a list name to output with [UP] [DOWN] keys and press [OK] key.

• Select among Key operator table, Confidential ID table, F code setup check table, Department code table, and Department management record table *.

• When the key operator program is terminated, print is started.

* This item is displayed on the list only when department management is set to ON (Effective) in the initial setup of the key operator program.

Key operator list

Confidential ID table

F code setup check table

Department code table

Department management record table

Anti Junk list

Used to print the current setup conditions of key operator program.

Used to print the contents of confidential box registration (confidential box number, confidential box name, ID number).

Used to print the contents of F code confidential box registration, F code relay group registration, and F code bulletin board registration.

Used to print registered numbers, department names, and department numbers.

Used to print communication time and communication pages in each department.

The reception rejection telephone number list is printed.

(3) Print method of record table

1) Press [SPECIAL FUNCTION] key in the FAX mode.

2) Select "PRINT" with [UP] [DOWN] keys, and press [OK] key.

3) Select "Record table" with [UP] [DOWN] keys, and press [OK] key.

4) Select a record table name to be printed with [UP] [DOWN] keys, and press [OK] key.

• Print reservation is made and print is made automatically.

• Printable record table

Communication record table, communication reservation table, document load check table, speed dial table, rapid dial table, group table, telephone number table, program table, relay group table, ID sender table, confidential reception check table

When [CA] key is pressed in the record table selection screen, the display returns to the initial screen. When [BACK] key is pressed, the display returns to the print selection screen of step 3).

The communication record table can be automatically printed by specifying time to print. Specification of print time can be set by the key operator program up to 2 times per day.

AR-FX4 KEY OPERATOR PROGRAM - 3

[8] FLASH ROM VERSION UP

PROCEDURE

(Items necessary for upgrade)

A

Personal computer

B

RS232C Cross cable (D-sub 9pin to D-sub 9pin, or D-sub 25pin to

D-sub 9pin)

C

Software for upgrade

(Type of ROM)

Flash ROM is directly attached to each PWB

(Targeted PWBs)

1

MCU-PWB

2

FAX-PWB

Diagrammatic sketch for upgrade method

(Personal computer)

A

B

RS232C Cross cable

(D-sub 9pin to D-sub 9pin) or

(D-sub 25pin to D-sub 9pin)

RS232C connector

(9pin or 25pin)

C

Download data

1

I/F Circuit (9pin)

MCU-PWB

1. Program download procedure (Main body program, FAX program)

Follow the procedure below to download the main body program and the FAX program:

1) Preliminary procedure: Connect PC and the main body with the download cable (RS-232C cable).

2) PC side: Boot the maintenance program.

3) Main body side: Turn on the power of LEOPARD, and it enters the download mode.

4) PC side: Check that the tree structure is displayed on the maintenance program.

Be sure to perform step 2) before turning on the power.

FAX-PWB

2

(AR-235/275)

(Files necessary for download)

• Maintenance program: mainte.exe

• Loader files

• IMC loader file: imcbios.cvt

• FAX loader file: faxbios.cvt

The maintenance program performs downloading of the following program:

• FAX program download

Note: The downloaded files such as Printer Control Board file should be copied in the same folder as that of the maintenance program.

When the tree is displayed, downloading can be performed.

(Double-click to perform.)

5) PC side: Double-click Special in the main tree items to extend the sub tree items, then double-click All Area Download.

6) PC side: The maintenance program asks the file name. Specify a download file (*.dat).

Download file:

• leopXXXX.dat: File for collective download (IMC, FAX)

XXXX: Release version (Leop0114.dat, etc.)

7) PC side: When a download file is specified, the downloading procedure advances automatically.

Time required for downloading is as follows:

• Main body program download time: About 5 min

• FAX program download time: About 5 min

8) PC side: When the message below is displayed, downloading is completed.

End message: Download Complete

9) After-process: Terminate the maintenance program, and turn off and on the power of the main body.

With the above procedures, downloading is completed.

AR-FX4 FLASH ROM VERSION UP PROCEDURE - 1

2. Others (Error list)

The list below describes errors occurring during download and countermeasures.

No

01

02

03

04

05

06

Error message Descriptions

COM Port Open Error !

This error message is displayed when a COM port which is disabled is selected or when there is an abnormal

COM port.

TimeOut Error !

Receive Error !

Panel Size Error !

Destination Error !

Printer Control Board

FirmWare Download

Send Error !

[Countermeasures]

Select another COM port which is enable. Check if there is any software which is using the COM port.

This error message is displayed when no response is sent back from the remote party for 10 sec.

[Countermeasures]

Once reset the maintenance software and the machine, then download again.

This error message is displayed when data received from the remote party are abnormal.

[Countermeasures]

Once reset the maintenance software and the machine, then download again.

This error message is displayed when the download file size is specified to 8MB though the machine panel is of

4MB size.

[Countermeasures]

Specify a download size suitable for the machine panel size, and download again.

This error message is displayed when the destination of the machine panel does not coincide with that of the download file.

[Countermeasures]

Specify the download file suitable for the destination of the machine panel, and download again.

This error message is displayed when an error occurs during downloading of the printer control board firmware.

[Countermeasures]

Execute SIM 67-14 on the machine panel to check that "Please Send Data" is displayed, and download again.

AR-FX4 FLASH ROM VERSION UP PROCEDURE - 2

[9] TROUBLE CODE LIST

1. Machine trouble codes

Trouble code

Main code

Sub code

F6

Details of trouble

00 Content F6-**: MCU-FAX communication trouble

Detail Communication setup error/framing/parity/ protocol error

Cause FAX control PWB connector disconnection

Check and remedy

Defective harness between FAX control

PWB and MCU PWB

Motherboard connector pin breakage

FAX control PWB ROM error/Data error

Check connector/harness of FAX control

PWB and MCU PWB.

Check the grounding of the copier.

Check FAX control PWB ROM.

10 Content FAX control PWB trouble

Detail Communication trouble between MCU and

FAX control PWB

Cause FAX control PWB connector disconnection

Defective harness between FAX control

PWB and MCU PWB

Motherboard connector pin breakage

FAX control PWB ROM error/Data error

Check and remedy

Check connector/harness of FAX control

PWB and MCU PWB.

Check the grounding of the copier.

Check FAX control PWB ROM.

80 Content FAX control PWB communication trouble

(Protocol)

Detail Communication trouble between MCU and

FAX control PWB (Protocol error)

Cause FAX control PWB connector disconnection

Defective harness between FAX control

PWB and MCU PWB

Motherboard connector pin breakage

FAX control PWB ROM error/Data error

Check and remedy

Check connector/harness of FAX control

PWB and MCU PWB.

Check the grounding of the copier.

Check FAX control PWB ROM.

81 Content FAX control PWB communication trouble

(Parity)

Detail Communication trouble between MCU and

FAX control PWB (Parity error)

Cause FAX control PWB connector disconnection

Defective harness between FAX control

PWB and MCU PWB

Motherboard connector pin breakage

FAX control PWB ROM error/Data error

Check and remedy

Check connector/harness of FAX control

PWB and MCU PWB.

Check the grounding of the copier.

Check FAX control PWB ROM.

Trouble code

Main Sub code

F6 code

Details of trouble

82 Content FAX control PWB communication trouble

(Over-run)

Detail Communication trouble between MCU and

FAX control PWB (Overrun error)

Cause FAX control PWB connector disconnection

Defective harness between FAX control

PWB and MCU PWB

Motherboard connector pin breakage

FAX control PWB ROM error/Data error

Check connector/harness of FAX control Check and remedy

PWB and MCU PWB.

Check the grounding of the copier.

Check FAX control PWB ROM.

84 Content FAX control PWB communication trouble

(Framing)

Detail Communication trouble between MCU and

FAX control PWB (Framing error)

Cause FAX control PWB connector disconnection

Defective harness between FAX control

PWB and MCU PWB

Motherboard connector pin breakage

FAX control PWB ROM error/Data error

Check and remedy

Check connector/harness of FAX control

PWB and MCU PWB.

Check the grounding of the copier.

Check FAX control PWB ROM.

88 Content FAX control PWB communication trouble

(Timeout)

Detail Communication trouble between MCU and

FAX control PWB (Timeout error)

Cause FAX control PWB connector disconnection

Defective harness between FAX control

PWB and MCU PWB

Motherboard connector pin breakage

FAX control PWB ROM error/Data error

Check and remedy

Check connector/harness of FAX control

PWB and MCU PWB.

Check the grounding of the copier.

Check FAX control PWB ROM.

99 Content Machine-FAX board language error

Detail The machine language setup does not coincide with the FAX board language setup.

Cause FAX board correction error

SIM setup error

Check and remedy

Check the firmware of the FAX board and the combination of the panel screen data, and download the correct version, if necessary.

Check the machine language information.

(Machine language setup:SIM 26-22)

AR-FX4 TROUBLE CODE LIST - 1

2. Communication result code

Described on the communication report table, the communication management table, and the protocol communication report table when communication is completed.

A. Composition of communication report code

Communication result X X (X X X X)

Upper 2 digits of a communication result code: Communication report code of 00 - 90 (Refer to the list of communication report codes.)

Lower 4 digits of a communication result code: Codes used by serviceman.

Top 2 digits Communication report sub code 1 (Refer to the list of communication sub code 1.)

Bottom 2 digits Communication report sub code 2 (Refer to the list of communication sub code 2.)

Note) Communication report sub code 1 and sub code 2 are in hexadecimal. (The others are in decimal.)

< Communication result code list>

25

26

27

28

21

22

23

24

29

30

31

17

18

19

20

13

14

15

16

9

10

11

12

7

8

5

6

Result code

0

3

4

1

2

Final reception signal

(Transmitting side)

Abnormal signal

NSF, DIS

CFR

FTT

MCF

PIP, PIN

RTN, RTP

No signal, DCN

PPR

RNR

CTR

ERR

Abnormal signal

NSF, DIS

CFR

FTT

MCF

PIP, PIN

RTN, RTP

No signal, DCN

PPR

RNR

CTR

ERR

V.8 Phase-1

V.8 Phase-2

V.8 Phase-3

Final reception signal

(Receiving side)

Abnormal signal

(SID), (SUB), NSS, DCS

(PWD), (SEP), NSC, DTC

EOP

EOM

MPS

PRI-Q

DCN

PPS-EOP

PPS-EOM

PPS-MPS, PPS-NULL

RR

CTC

EOR-Q

PPS-PRI-Q

Abnormal signal

SID, SUB, NSS, DCS

PWD, SEP, NSC, DTC

PPS-EOP

PPS-EOM

PPS-MPS, PPS-NULL

PRI-Q

DCN

RR

CTC

EOR-Q

PPS-PRI-Q

V.8 Phase-1

V.8 Phase-2

V.8 Phase-3

(Note) For result codes 16 - 31, V.34 mode communication.

For 32 or later, refer to the table below.

<Communication result code list>

Result code

(Communication result)

0 – 31

33

34

35

38

42

44

46

48

49

50

51

56

Communication report result column

Refer to the previous table.

Busy

Cancel

Power OFF

Reception memory over

Reception length over

Communication interruption content

Depends on the communication disconnection position. For 16 or later, V.34 mode communication.

The calling side cannot connect the line with the other party.

When a communication interruption command is delivered during transmission or reception, <Send/Receive/

Poll/Bulletin>

When the operation is interrupted by the stop key.

When the power is cur off during sending or receiving,

<Send/Receive/Poll/Bulletin>

When memory is over during reception, <Receive/Poll>.

When printing cannot be performed during reception due to inhibition of proxy reception, <Receive/Poll>

When the received data length of one page exceeds the range during reception, <Receive/

Poll>

Document error When a document jam occurs during direct transmission,

<Send>

No response from the other party

When the FAX signal from the other party is not detected within T1 time, <Send/Poll>

OK

The other party has no polling function.

Communication normal end

When the called side has no polling function in polling reception, <Poll>

When the called side has no transmission data, <Bulletin>

Polling is not accepted.

Polling allow number discrepancy

Interface not accepted

When DCN is received for

DTC in polling reception,

<Poll>

When there is no transmission data in polling transmission,

<Bulletin>

When the allow number does not coincide in polling transmission, <Bulletin>

When the system number does not coincide in polling transmission, <Bulletin>

1) When DCN is received for

NSS in transmission of the relay instruction, <Send>

2) When a receiving station number that is not registered is instructed in reception of the relay instruction, <Receive>

3) When F code relay instruction is received during F code relay broadcasting, <Receive>

AR-FX4 TROUBLE CODE LIST - 2

Result code

(Communication result)

59

60

Communication report result column

The other party has no function of F code bulletin board.

F code polling is not accepted.

Communication interruption content

When the other party machine does not have DIS bit 47

(Selective polling function) in F code polling (ringing), <Poll>

When DCN is received for SEP in F code polling (ringing),

<Poll>

When there is no transmission data for SEP in bulletin board,

<Bulletin>

61

62

63

64

F code bulletin board number discrepancy

F code bulletin board password discrepancy

The other party has no function of F code.

F code is not accepted.

When the sub address (bulletin board number (SEP)) does not coincide in bulletin board,

<Bulletin>

When the pass code (PWD) does not coincide in bulletin board, <Bulletin>

When the other party machine does not have DIS bit 49 (sub address capacity) in F code transmission, <Send>. Check that the other party machine conforms to F code.

When F code is transmitted,

<Send>

1) When DCN is received for

SUB, check the BOX number.

2) When DCN is received for

SID, check BOX number and the pass code.

When F code is received,

<Receive>

When the F code relay broadcast function or the F code confidential reception function is inhibited with soft switches.

67 F code password discrepancy

When the pass code (SID) does not coincide in F code reception, <Receive>

68 BOX NO. NG When a BOX number that is not registered is instructed

(SUB discrepancy) in F code reception, <Receive>

• When communication result is OK, the communication result sub code 1 and sub code 2 are 0000.

• < > indicates the communication means. <Send>, send; <Receive>, receive; <Poll>, polling; <Bulletin>, bulletin board

The status code from the modem in V.34 mode is indicated with the communication result sub code 1 (top 2 digits). However, the communication sub code 1 is 00 in communication other than V.34 mode.

<Communication result sub code list 1 >

Code

(Hexadecimal)

21

22

23

24

25

26

27

28

29

2A

2B

2C

31

91

92

93

94

95

97

98

A1

B0

B1

B2

B3

B4

B5

B6

C0

C1

C2

C3

C4

C5

C7

D0

D1

D2

D3

D4

D5

D6

D8

DA

DB

Phase 2

Control channel

Primary channel resync

Phase 3

Phase 4

Descriptions

Timeout standby for INFO0

Check sum error in INFO0

Timeout standby for tone A or B

Timeout standby for the first phase reversion

Timeout standby for cut off tone probing

Timeout standby for the second phase reversion

Timeout standby for probing end

Timeout standby for the third phase reversion

Timeout standby for INFO1

Check sum error in INFO1

Tone found before INFO1

Unexpected INFO0 found

Timeout standby for turning off the reception control channel

Error in the first CC train

Timeout standby for PPh

Tone A/B detected in CC retrain

Timeout standby for ALT

Ach found

Timeout standby for turning off CC

FED OFF with CC data

A trouble which cannot be solved in phase 2. Retrain is forcibly made.

Trouble in S sequence of HDXresync

FED OFF in S sequence of HDXresync

Unexpected completion of S sequence in HDX-resync

Timeout standby for S-Sbar in

HDX-resync

Timeout standby for S-Sbar in

HDX-resync

Timeout standby for S in HDXresync

Timeout for sync with PP

Trouble in S sequence of phase 3

FED OFF in S sequence of phase 3

Unexpected completion of S sequence

Timeout standby for S-Sbar of phase 3

Timeout standby for S-Sbar of phase 3

Timeout standby for S of phase 3

Training due to TRN failure

Trouble in S sequence of phase 4

FED OFF in S sequence of phase 4

Unexpected completion of S sequence

Timeout standby for S-Sbar of phase 4

Timeout standby for S-Sbar of phase 4

Timeout standby for S of phase 4

Timeout standby for MP

Timeout standby for E

Timeout at renegotiation of the transmitter rate

Timeout at MPh of the transmitter

AR-FX4 TROUBLE CODE LIST - 3

Code

(Hexadecimal)

E2

E3

E4

FE

FF

71

96

61

Descriptions

Retrain Retrain detected in phase 2

Retrain detected in phase 3

Retrain detected in phase 4

DTR OFF in retrain

TX setup port flag

Writing is not made to the first mapping frame.

Clear down PSTN clear down request is made.

HDLC The transmitter sends HDLC abort in underflow state.

<Communication result sub code 2 >

Result code 2

02

03

05

06

07

11

12

13

14

20

21

22

23

24

25

26

28

Communication interruption content

EOL time over

Carrier detection time over

Time-up in phase C (8min)

Memory image decoding error

Memory image decoding error

Polarity reversion detection

Invalid command reception

Time over (1min timer/6sec timer)

PUT error

Polarity reversion detection

Invalid command reception

Fall back retry number over

Resend over of the number of times of command retry

Time over (T5 timer)

Time over (T5 timer) in V.34 mode

Time over occurrence during shift from

Primary to Control in V.34 mode

Modem chip answering NG

Transmission/

Reception

Reception

Reception

Transmission

Reception

Transmission

Reception

Reception

Reception

Reception

Transmission

Transmission

Transmission

Transmission

Transmission

Transmission

Transmission

Transmission/

Reception

3. List of buzzer sounds in case of FAX abnormality

– : Long sound • : Single sound 3: Pause

Example: In case of TEL/LIU connection abnormality

{{– • • • • •} repeats {Pee • pi • pause • pi • pi • pi • pi}.

Beep sound pattern

– • • •

– • • • •

Information content

Expanded memory connection abnormality

Internal DMA transfer abnormality

– • • • • •

– • • •

– • • • •

– • • • •

TEL/LIU PWB connection abnormality

Program ROM (main section) writing not completed

Program ROM (font section) writing not completed

Work DRAM (IC13, 14) abnormality

Detail Trouble content

Expanded memory insertion abnormality Expanded memory reinsertion

Internal DMA transfer operation abnormality

TEL/LIU PWB is not connected to the main PWB.

Program ROM (main section) data abnormality

Program ROM (font section) data abnormality

Work DRAM abnormality

PWB solder trouble, PWB parts trouble

Download retry

Download retry

– • • • • •

– • • • • • •

– • – –

SRAM (IC41) abnormality 1

SRAM (IC41) abnormality 2

MCU upload no responding MCU PWB does not respond.

IC13, 14: PWB solder trouble, PWB parts trouble

IC41: PWB solder trouble, PWB parts trouble

IC41: PWB solder trouble, PWB parts trouble

MCU PWB - main PWB connection

– • • –

– • • • –

System abnormality 1

System abnormality 2

Various internal operation abnormality

Various internal operation abnormality

PWB solder trouble, PWB parts trouble

PWB solder trouble, PWB parts trouble

AR-FX4 TROUBLE CODE LIST - 4

[10] ELECTRICAL SECTION

1. Block diagram

A. Main block diagram

PCL

COPIER

SCANNER

COPIER

PRINTER

COPIER CPU

LINE

EXTERNAL

TELEPHONE

TEL/LIU

PWB

S (1)

SCAN

I/F

S (2)

SUB

SCAN

2/3

MULTI-

PLICATION

FAX UNIT

FAX MAIN PWB

IMAGE PROCESS GA

SCAN PROCESS FLOW

S (3)

SDRAM

CON-

TROL

S (4)

SUB

S (3)

ROTATION

SCAN

SCAN

1/2

MULTI-

PLICATION

S (5)

MN860

65

I/F

CODE/

DECODE

MN86065

P (5)

PRINT

I/F

P (4)

RESO-

LUTION

CON-

VERSION

P (3)

3 3

P (2)

ROTATION

PRINT

P (1)

SDRAM

CON-

TROL

PRINT PROCESS FLOW

CPU

I/F

FAX

GA

I/F

DMAC

CON-

TROL

SRAM

CON-

TROL

IMAGE

PROCESS

MEMORY

SRAM

1Mbit

PAGE MEMORY

SDRAM

128Mbit

CPU

(SH7709A)

WORK

MEMORY

SDRAM

16Mbit

MODEM

FM336

PROGRAM

FLASH ROM

16Mb

REGIS-

TRATION

MEMORY

SRAM

2Mbit

IMAGE

MEMORY

(STANDARD)

FLASH ROM

16Mbit

MODEM

CON-

TROL

FAX PROCESS GA

CPU

I/F

IMAGE

GA

I/F

DMAC

CON-

TROL

MN860

65

I/F

CODE/

DECODE

MN86065

RTC

I/F

SRAM

CON-

TROL

IMAGE

PROCESS

MEMORY

SRAM

1Mbit

RTC SPEAKER

IMAGE

MEMORY

(EXPANDED)

FLASH ROM

2MB/4MB/8MB

EXPANSION

CONNECTOR

BUS

BUFFER

AR-FX4 ELECTRICAL SECTION - 1

B. TEL/LIU PWB block diagram

DC SEPARATE

POWER SUPPLY LINE

CONNECTION JACK

CURRENT DETECT SECTION

CML RELAY

ON HOOK

DP TRANSMISSION

CIRCUIT

LINE

CLOSE/

INTERFACE

CIRCUIT

TRANSFORMER

SWITCH CIRCUIT

SECTION

SP

MODEM

33600bps

V.34

ATT (0 – 15db)

PB SIGNAL

GENERATE

SECTION

PROGRAM

CONTROL ROM

FAX CONTROL

SECTION

(CPU, GATE ARRAY)

PSEUDO RBT SOUND

GENERATE SECTION

EXTERNAL

TELEPHONE

JACK

S RELAY

PHOTO

COUPLER

CI DETECT

TRANSFORMER

POWER SOURCE RECIVE CONDITION

AC120V

DC24V

DC5V

DC3.3V

GND

EARTH

TO EACH SECTION

READ SECTION

PRINT SECTION

COPY

CONTROL

SECTION

PRINTER I/F

(OPTION)

AR-FX4 ELECTRICAL SECTION - 2

7

6

5

8

8

7

6

5

8

7

6

5

8

7

6

5

7

6

5

8

3

2

1

4

4

3

2

1

4

3

2

1

4

3

2

1

3

2

1

4

7

6

5

8

3

2

1

4

7

6

5

8

7

6

5

8

7

6

5

8

3

2

1

4

3

2

1

4

3

2

1

4

E

10K R30

10K R20 R(NM) R29

AR-FX4 ELECTRICAL SECTION - 3

8

7

6

5

7

6

5

8

2

1

4

3

3

2

1

4

8

7

6

5

7

6

5

8

2

1

4

3

3

2

1

4

7

6

5

8

3

2

1

4

100K

100K

100K

100K

1K

R228

R229

R227

R226

R61

14 7 14 7 14 7 14 7 14 7 14 7 14 7

14 7

14 7

14 7

SKHU(NM) 1 SW

14 7

AR-FX4 ELECTRICAL SECTION - 4

8 4

1 2

E

14 7

AR-FX4 ELECTRICAL SECTION - 5

14 7

14 7 14 7

GND

GND

GND

2

GND

1

GND

1

14 7

14 7

10K

10K

R248

R247

R235

R234

R236

R233

R238

R237

10K

10K

10K

10K

10K

10K

R243

R242

R241

R244

R245

10K

10K

10K

10K

10K

6

5

7

8

8

7

6

5

8

7

6

5

8

7

6

5

3

2

4

1

4

3

2

1

4

3

2

1

4

3

2

1

AR-FX4 ELECTRICAL SECTION - 6

CD1IRQ-

CD1CLK

CD1RES-

CD1A1

CD1A0

CD1A2

CD1A3

CD1REQD0

CD1REQC0

CD1ACKC0-

CD1ACKD0-

CD1RD-

CD1CS-

CD1WR-

CD1UBE-

CD1D10

CD1D11

CD1D9

CD1D8

CD1D5

CD1D4

CD1D6

CD1D7

CD1D2

CD1D1

CD1D3

CD1D0

CD1D14

CD1D13

CD1D12

CD1D15

M1D11

M1D10

M1D9

M1D8

M1D5

M1D4

M1D6

M1D7

M1D1

M1D2

M1D3

M1D0

M1D13

M1D12

M1D15

M1D14

CDD[0]

CDD[1]

CDD[2]

CDD[3]

GND-280

VDD-279

GND-285

GND-286

CDD[4]

CDD[5]

CDD[6]

CDD[7]

VDD-291

GND-292

CDD[8]

CDD[9]

CDD[10]

CDD[11]

VDD-297

GND-298

VDD-303

VDD-304

CDD[12]

CDD[13]

CDD[14]

CDD[15]

CDACKD_N

CDCLK

CDIRQ

VDD-259

GND-260

CDA[0]

CDA[1]

CDA[2]

CDA[3]

VDD-265

VDD-266

GND-267

GND-268

CDCS_N

CDRD_N

CDWR_N

MD[4]

MD[5]

MD[6]

MD[7]

VDD-241

MD[10]

MD[11]

MD[8]

MD[9]

GND-242

GND-236

GND-247

GND-248

MD[12]

MD[13]

MD[14]

MD[15]

VDD-253

GND-254

VDD-235

VDD-229

VDD-230

MD[0]

MD[1]

MD[2]

MD[3]

TRES_N

CDRES_N

CDUBE_N

CDREQC

CDREQD

GND-274

VDD-273

CDACKC_N

274

275

276

277

272

273

278

279

280

281

282

283

284

285

286

287

288

289

270

271

297

298

299

300

301

302

303

304

293

294

292

295

296

290

291

236

237

238

239

240

241

242

243

232

233

234

235

244

245

246

247

248

249

250

251

230

231

229

254

255

256

257

252

253

258

259

260

261

262

263

264

265

266

267

268

269

TP952

TP947

TP949

TP950

TP948

TP953

TP951

TP954

TP1059

TP1060

TP374

TP364

TP363

TP375

TP1058

TP1057

TP957

TP956

TP958

TP955

TP961

TP962

TP960

TP959

TP360

TP361

TP372

TP359

TP1061

TP428

TP371

TP1062

TP1005

TP1006

TP1004

TP1003

TP998

TP999

TP994

TP997

TP996

TP1000

TP1001

TP1002

TP970

TP995

TP971

TP993

8

7

6

5 4

3

2

1

AR-FX4 ELECTRICAL SECTION - 7

RW (RD/WR-)

DREQ[0]_N

DREQ[1]_N

DRAK[0]_N

DRAK[1]_N

BSSEL[0]

BSSEL[1]

VDD-126

GND-127

GND-115

VDD-114

IRQ[1]_N

IRQ[0]_N

GND-134

GND-133

GND-138

VDD-137

GND-145

VDD-144

VDD-152

VDD-151

VDD-113

WAIT_N

D[7]

D[6]

145

144

143

142

141

140

139

138

149

148

147

146

137

136

135

134

133

132

131

130

151

150

152

127

126

125

124

129

128

123

122

121

120

119

118

117

116

115

114

113

112

105

104

103

102

101

100

99

98

97

96

95

94

93

92

91

90

84

83

82

81

80

79

78

77

88

87

89

86

85

109

108

107

106

111

110

D[5]

D[4]

D[3]

D[2]

GND-130

D[11]

D[10]

D[9]

D[8]

GND-141

GND-96

GND-95

CS4_N

CS0_N

A[21]

A[20]

A[22]

BS_N

CS6_N

VDD-78

VDD-77

A[15]

A[14]

A[16]

A[13]

A[12]

A[11]

A[10]

A[8]

A[7]

A[9]

A[6]

A[5]

A[4]

A[3]

A[2]

A[1]

WE0_N

RD_N

WE1_N

CLK

GND-116

GND-123

MODE3

D[1]

D[0]

D[13]

D[12]

D[15]

D[14]

GND-148

TP916

A21

A22

A20

TP416

TP690

TP691

0

R212

WE0-

WE1-

RD-

CS6-

BS-

CS4-

CS0-

RD/WR-

WAIT-

DRAK[0]

DRAK[1]

DREQ[1]-

DREQ[0]-

A11

A10

A13

A12

A14

A15

A16

A2

A1

A3

A4

A6

A5

A7

A8

A9

D5

D4

D3

D2

D7

D6

D10

D11

D9

D8

D1

D0

D14

D15

D13

D12

TP684

TP915

IRQ1-

MD3

IRQ0-

CKIO_GA1

TP914

8 4

8 4

8

7

6

5 4

3

2

1

8

7

6

5

7

6

5

8

8

7

6

5

6

5

8

7

4

3

2

1

3

2

1

4

2

1

4

3

4

3

2

1

AR-FX4 ELECTRICAL SECTION - 8

4 11

E E

E

E

E

E

E

AR-FX4 ELECTRICAL SECTION - 9

BSSEL[0]

BSSEL[1]

CLK_SYS

D[2]

D[3]

D[4]

D[5]

GND-285

GND-282

D[6]

D[7]

VDD-289

D[10]

D[11]

D[8]

D[9]

GND-293

GND-290

GND-286

VDD-296

GND-297

VDD-278

GND-279

NC[2]

NC[3]

D[0]

D[1]

GND-275

IRQ[2]_N

D[12]

D[13]

D[14]

D[15]

VDD-303

VDD-304

GND-300

A[12]

A[13]

A[11]

A[2]

A[3]

A[1]

A[4]

A[5]

A[8]

A[9]

A[6]

A[7]

A[10]

A[15]

A[16]

A[14]

VDD-230

VDD-229

GND-247

GND-248

A[22]

A[23]

A[21]

A[24]

A[25]

A[17]

A[18]

A[19]

A[20]

CS5_N

NC[1]

RD_N

BS_N

WE0_N

WE1_N

WAIT_N

VDD-265

VDD-266

GND-267

GND-268

CKIO_GA2

IRQ2-

WE0-

RD-

WE1-

WAIT

BS-

CS5-

0

R217

TP210

D15

D14

D12

D13

A24

A23

A25

A21

A22

A19

A20

A18

A17

215 TP

257

258

256

260

261

259

263

264

262

266

267

265

269

270

268

272

273

271

275

276

274

278

279

277

281

282

280

284

285

283

287

288

286

290

291

289

293

294

292

296

297

295

299

300

298

302

303

304

301

234

235

236

237

230

231

229

232

233

239

240

238

242

243

241

245

246

244

248

249

247

251

252

250

254

255

253

212

213

D1

D0

TP

TP

TP211

D5

D4

D3

D2

TP214

D6

D7

D9

D8

D11

D10

A13

A14

A12

A15

A16

A10

A11

A5

A4

A3

A6

A7

A2

A1

A8

A9

6

5

8

7

4

3

2

1

AR-FX4 ELECTRICAL SECTION - 10

SDRAM_RAS_N

SDRAM_CAS_N

SDRAM_WR_N

SDRAM_DQM0

SDRAM_DQM1

SDRAM_BA[1]

SDRAM_BA[0]

SDRAM_CS_N

SDRAM_CKE

SDRAM_A[3]

SDRAM_A[2]

SDRAM_CLK

SDRAM_A[0]

SDRAM_A[1]

SDRAM_A[4]

GND-134

GND-133

VDD-152

VDD-151

GND-143

VDD-142

MD[14]

MD[13]

MD[15]

MD[11]

MD[10]

MD[12]

GND-125

VDD-114

VDD-113

GND-115

MA[15]

MA[14]

MD[2]

MD[1]

MD[0]

MA[13]

MA[12]

GND-105

CDD[14]

CDD[13]

CDD[12]

CDD[15]

VDD-78

VDD-77

CDD[11]

MA[1]

MA[0]

MA[2]

MA[4]

MA[3]

GND-95

MA[11]

MA[10]

MA[8]

MA[7]

MA[9]

MA[6]

MA[5]

GND-96

MWE_N

MOE_N

GND-87

VDD-86

MCE_N

TRES_N

VDD-104

MD[9]

MD[8]

MD[7]

MD[6]

MD[4]

MD[3]

MD[5]

VDD-124

GND-116

147

146

145

144

142

141

143

151

150

152

149

148

139

138

140

136

135

137

133

132

134

130

129

131

127

126

128

124

123

125

121

120

122

118

117

119

115

114

116

112

111

113

109

108

110

106

105

107

103

102

101

104

94

93

95

91

90

92

99

98

97

96

88

87

89

85

84

86

82

81

83

79

78

77

80

100

MNR14 33

8

9

7

TP196

TP201

TP19

TP19

TP19

TP195

TP200

4

5

3

4 TP19

TP193

TP192

TP20

TP20

TP20

TP206

TP207

2

1

TP833

6

5

7

TP834

TP85

TP85

TP83

TP83

TP83

4

6

7

2 TP20

TP854

TP848

TP84

TP84

TP84

TP845

7

4

9

TP850

1

2

TP853

813

819

818

5

TP

TP

TP29

TP817

TP816

TP

TP843

TP84

TP84

TP82

TP82

TP84

5

6

0

3

1

TP82

TP83

TP82

TP82

TP82

TP822

TP821

0

9

2

9 TP83

TP838

TP840

TP828

TP83

TP82

TP83

7

6

5

8

6

5

8

7

CD2D12

CD2D13

CD2D11

CD2D14

CD2D15

M2A6

M2A5

M2A9

M2A8

M2A7

M2A10

M2A11

M2WE-

M2OE-

M2A4

M2A3

M2A2

M2A1

M2A0

M2A14

M2A15

M2A13

M2A12

M2D1

M2D0

M2D2

M2CE-

M2D5

M2D4

M2D3

M2D8

M2D7

M2D9

M2D6

M2D12

M2D11

M2D10

M2D13

M2D15

M2D14

MNR14 33

MNR14 33

BR82

BR83

6

5

8

7

3

2

1

4

4

3

2

1

8

7

6

5

MNR14 33

4

3

2

1

BR84

4

3

2

1

BR85

792 TP

TP793

TP794

TP

TP

TP

782

781

783

TP780

TP209

784 TP

TP786

TP785

TP

TP

TP

TP790

788

787

789

TP791

SDRAM_BA0

SDRAM_BA1

SDRAM_A2

SDRAM_A3

SDRAM_A4

SDRAM_A0

SDRAM_A1

SDRAM_WR-

SDRAM_CAS-

SDRAM_CLK

SDRAM_CS-

SDRAM_RAS-

SDRAM_CKE

SDRAM_DQM0

SDRAM_DQM1

8

7

6

5

8

7

6

5

6

5

7

8

6

5

7

8

4

3

2

1

4

3

2

1

3

2

4

1

3

2

4

1

AR-FX4 ELECTRICAL SECTION - 11

6

5

7

8

6

5

7

8

8

7

6

5

8

7

6

5

3

2

4

1

3

2

4

1

4

3

2

1

4

3

2

1

8

7

6

5 4

3

2

1

6

8

7

1

E

AR-FX4 ELECTRICAL SECTION - 12

TP1229

TP1228

8

7

6

5

7

6

5

8

8

7

6

5

4

3

2

1

3

2

1

4

4

3

2

1

6.8k

7.5k

10k

AR-FX4 ELECTRICAL SECTION - 13

AR-FX4 ELECTRICAL SECTION - 14

35V 47

µ

AR-FX4 ELECTRICAL SECTION - 15

All rights reserved.

Printed.

No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic; mechanical; photocopying; recording or otherwise without prior written permission of the publisher.

Trademark Acknowledgments

Microsoft Windows, MS-DOS, Windows NT, Windows 2000 are trademarks of Microsoft

Corporation in the U. S. A. and other countries.

Macintosh, Power Macintosh, Mac OS, LaserWriter, and AppleTalk are registered trademarks of

Apple Computer, Inc.

IBM, PC/ AT, and PowerPC are trademarks of International Business Machines Corporation.

Pentium is a registered trademark of Intel Corporation.

PCL is a trademark of the Hewlett- Packard Company.

PostScript

is a registered trademark of Adobe Systems Incorporated.

NetWare is a registered trademark of Novell, Inc.

All other trademarks and copyrights are the property of their respective owners.

Digital Document Systems Group

Quality & Reliability Control Center

Yamatokoriyama, Nara 639-1186, Japan

2001 June Printed

advertisement

Key Features

  • Copy and print
  • Fax sending and receiving
  • Automatic document feeder
  • Multiple resolution settings
  • Memory transmission

Frequently Answers and Questions

What is the maximum document width that can be scanned?
The maximum document width that can be scanned is 297mm (11.7").
What are the different compression methods supported?
The SHARP AR-FX4 supports MH, MR, MMR, and JBIG compression methods.
What is the maximum number of destinations that can be registered for broadcast transmission?
The maximum number of destinations that can be registered for broadcast transmission is 200.