SHARP AR-235/275 AR-FX4 digital copier SERVICE MANUAL
The SHARP AR-235/275 AR-FX4 is a digital copier with a printer option and a FAX expansion kit. It can scan and copy documents, as well as send and receive faxes. The expansion kit allows the user to add more memory to the machine to increase the number of pages that can be stored for later transmission. The device includes a number of features that make it a convenient and versatile tool, including automatic document feeders, a variety of resolution settings, and a variety of transmission modes.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
SERVICE MANUAL
CODE: 00ZARFX4//A1E
DIGITAL LASER COPIER/
PRINTER OPTION
FAX EXPANSION KIT
(For U.S.A./Canada)
MODEL
AR-FX4
EXPANSION MEMORY
2MB: AR-MM5
4MB: AR-MM6
8MB: AR-MM7
CONTENTS
[1] OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
[2] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
[3] INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
[4] ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
[5] SIMULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
[6] SOFT SWITCH DESCRIPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
[7] KEY OPERATOR PROGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
[8] FLASH ROM VERSION UP PROCEDURE . . . . . . . . . . . . . . . . . . 8-1
[9] TROUBLE CODE LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
[10] ELECTRICAL SECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1
Parts marked with “ ” are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
SHARP CORPORATION
This document has been published to be used for after sales service only.
The contents are subject to change without notice.
CONTENTS
[1] OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
[2] SPECIFICATIONS
1. Communication system . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
2. Scanning system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
3. Image process system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
4. Print system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
5. Transmission function system. . . . . . . . . . . . . . . . . . . . . . . 1-2
6. Reception function system . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
7. Registration system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
8. Telephone function system . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
9. Memory system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
10. Additional information function for transmission . . . . . . . . . 1-4
11. Additional print function when receiving . . . . . . . . . . . . . . . 1-4
12. Recording table system . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
13. Others . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
[3] INSTALLATION PROCEDURE
1. Install of expansion kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
A. Parts included. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
B. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
2. Mounting of additional memory (AR-MM5, MM6, MM7) . . . 3-3
[4] ADJUSTMENTS
1. Density section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
A. FAX mode density adjustment (Overall mode) (<FAX mode> SIM 46-12) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
B. FAX mode density adjustment (Individual mode) (<FAX mode> SIM 46-13 – 16) . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
2. Communication section . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
A. Dial test (<FAX mode> SIM 66-13) . . . . . . . . . . . . . . . . 4-2
[5] SIMULATION
1. Entering the simulation mode/cancel of simulation mode . 5-1
2. Simulation code list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
3. Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
[6] SOFT SWITCH DESCRIPTIONS
1. Quick reference of FAX soft SW setup change . . . . . . . . . 6-1
2. Soft switch list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
3. Soft switch descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19
[7] KEY OPERATOR PROGRAM
1. List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
2. Operating procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
A. Common procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
B. List output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
[8] FLASH ROM VERSION UP PROCEDURE
1. Program download procedure (Main body program, FAX program) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
2. Others (Error list) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
[9] TROUBLE CODE LIST
1. Machine trouble codes . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
2. Communication result code . . . . . . . . . . . . . . . . . . . . . . . . 9-2
A. Composition of communication report code . . . . . . . . . 9-2
3. List of buzzer sounds in case of FAX abnormality . . . . . . . 9-4
[10] ELECTRICAL SECTION
1. Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1
A. Main block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1
B. TEL/LIU PWB block diagram. . . . . . . . . . . . . . . . . . . . 10-2
2. Circuit diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3
A. FAX MAIN PWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3
B. TEL/LIU PWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-13
[1] OUTLINE
This unit is a fax expansion kit which provides facsimile functions by attaching to the digital machine AR-235/275 series.
To expand facsimile functions, use of SPF/RSPF is recommendable.
By attaching a job separator/finisher, copy output and fax output can be separately discharged to different trays.
RSPF (AR-RP3)
The fax board of the fax expansion kit is provided with 2MB flash memory (standard). An expansion memory of one of 2MB/4MB/8MB can be added. (2MB expansion memory for fax, AR-MM5; 4MB expansion memory for fax, AR-MM6; 8MB expansion memory for fax, AR-MM7)
SPF (AR-SP4)
Job separator
(AR-TR3)
FAX expansion kit
(AR-FX4)
2MB 4MB 8MB
AR-MM5 AR-MM6 AR-MM7
Expansion memory (One of them is attached to.)
Finisher
(AR-FN5)
[2] SPECIFICATIONS
1. Communication system
(1) Electronic transmission system
Transmission time About 3 sec (Super G3/33660bps)
About 6sec (G3 ECM/14400bps)
Compression system MH, MR, MMR, JBIG
Modem speed 33600bps
→
2400 auto fall back
Mutual communication
Super G3/G3
Employed line Public Switched Telephone Network
(PSTN), Private Branch Exchange (PBX)
One line (no additional line allowed) Number of employed lines
ECM YES
2. Scanning system
(1) Document size
Max. document width
Unscanable area
297mm (11.7")
Auto detection size
OC
SPF/
RSPF
Lead edge 5mm or less, rear edge 5mm or less left & right edges 6mm or less
AB series A3/B4/A4/A4R/A5
Inch series 11 x 17/8.5 x 14/8.5 x 11/
8.5 x 11R/5.5 x 8.5
AB series A3/B4/A4/A4R/A5
Inch series 11 x 17/8.5 x 14/8.5 x 11/
8.5 x 11R/5.5 x 8.5
Document size specified
AB series
Inch series 11 x 17/8.5 x 14/8.5 x 11/
8.5 x 11R/5.5 x 8.5/A4/A4R
AB series
+ foolscap
A3/B4/A4/A4R/A5/8.5 x 11/
8.5 x 11R/8.5 x 13
YES
A3/B4/A4/A4R/A5/8.5 x 11/
8.5 x 11R
Duplex document specified
Long document Max. 1000mm,.depending on the document width and resolution
Differs in single/duplex.
(2) Transmission mode document load quantity scan cycle (SPF/RSPF capacity)
SPF/OC transmission select
Continuous auto paper feed
Document load capacity
NO (Selection inhibited during scanning of a document)
YES
30 sheets
(3) Half-tone reproduction density adjustment
Document scan cycle About 40 pages/min (Normal, A4R memory transmission, guaranteed scan pages = 30 pages)
Document scan speed
About 1.5sec/page (Normal, A4R memory transmission)
Half-tone (Photo mode)
Density selection
Equivalent to 256 gradations (Combination of fine/super fine/ultra fine is possible.)
Auto/manual in 5 steps
AR-FX4 OUTLINE/SPECIFICATIONS - 1
3. Image process system
(1) Image selection
Normal
Fine
Super fine
Ultra fine
8dot/mm x 3.85line/mm
8dot/mm x 7.7line/mm
8dot/mm x 15.4line/mm
16dot/mm x 15.4line/mm: ITU-T conforming
(reception impossible without additional memory. Receives in super fine mode.)
(2) Print resolution
600dpi (with resolution correction)
4. Print system
(1) Recording size
Max. record width 293mm (11.5")
Recording paper YES (All sizes except for multi paper feed.
→ size detection Recognition of the set size. The tray has no function to detect the actual paper size.)
Recording paper size
AB series
Inch series
A3/B4/A4/A4R/A5/8.5 x 11/8.5 x 11R
11 x 17/8.5 x 14/8.5 x 11/8.5 x 11R/
5.5 x 8.5/A4/A4R
(2) Recording paper
Cassette capacity Machine: 500 x 1 or 500 x 2
Option: 500 x 1 or 500 x 2
YES Recording paper empty detection
Paper feed All installed trays except for multi-manual tray.
5. Transmission function system
(1) Simplified dialing function
Rapid key dialing 50 items
Speed dialing 300 items
Group dialing
Telephone directory transmission
Chain dialing
Redialing
Program
Mode recall
50 items (including rapid key dialing)
Any of other parties registered to speed dialing, rapid key dialing, and group dialing can be searched for using the first 10 letters.
YES
The preceding number is saved, and is not cleared even with CLEAR ALL key.
9 items
NO
(2) F-code communication
Sub address
Password
(3) Time specification
YES (Max. 20 digits)
YES (Max. 20 digits)
Time specification:
Transmission/polling
(4) Recall mode
Time is specified in transmission/polling.
Auto recall mode when other party is busy.
Interval
Number of times
1min to 15min, default 3min
0 to 14 times / 0: No resend
Default 2 times
Auto recall mode when in a communication error
Interval 1min to 15min / 0: Resend immediately after disconnection of the line
Default 1min
1 time only / 0: No resend
Default 1 times
Number of times
Number of transmissions simultaneously.
Send page After the error page
Max. 50 items counted in recall mode
(5) Automatic reduction transmission
Message is reduced according to the receiver’s machine.
YES (ON/OFF by key operator program)
(6) Memory transmission/direct transmission
Memory transmission
Memory transmission
Number of transmission reservation to be set
Process in memory full
Quick online transmission
Direct transmission
Default setup
YES
Max. 50 items
Transmission cancel or only scanned data transmission
YES (Enable/Disable setup by key operator program)
YES (30 pages from SPF, only 1 page from OC)
Set by key operator program
(7) Broadcast function
Broadcast transmission
Group dialing
Relay broadcast transmission
Number of destinations
200 destinations (When group dialing is used, the number of other parties registered to group dialing is added.)
Broadcast key, group key Transmission method
Usable dial
Instructing station
10-key entry, rapid key dialing, speed dialing.
However, those of which sub address is registered cannot be used.
Transmitted by group dialing registered to rapid key dialing
Only from the machine having Sharp relay broadcast instructing transmission function
Relay station Only from the machine having Sharp relay broadcast transmission function
Multiple relay NO
10 groups Number of relay groups
Number of receiving stations that may be specified per group
120 items in rapid key dialing, 240 items in speed dialing
(8) Confidential function
Confidential transmission
Other station Only Sharp machine having confidential function
(9) Scan specification
Page division
Page coupling
(10) Priority function
YES (Allowed only from OC)
NO
Transmission reservation interrupt
Broadcast interrupt
YES (by direct transmission)
YES (by direct transmission)
(11) Serial transmission function
Serial transmission NO
(12) Rotation transmission
Paper size AB series
Inch series
A4
→
A4R, 8.5 x 11
→
8.5 x 11R
8.5 x 11
→
8.5 x 11R, A4
→
A4R,
(13) Book document transmission
Transmission method
Page division
By OC mode
YES
AR-FX4 OUTLINE/SPECIFICATIONS - 2
(14) Finish stamp
NO
(15) Bulletin board, polling transmission functions
Bulletin board Bulletin board
Protection function
Check by other party’s number
Check by matching of system number (user’s own machine), ID number (other party’s machine) (between Sharp machines only)
YES
YES
YES
6. Reception function system
(1) Reception mode
Default setup
Automatic reception
Manual reception
Automatic reception (Reception state switchable)
YES Automatic reception setup
Number of calls 0 to 9 times (Factory setup 2 times, variable)
Automatic switching of
Telephone/Fax
NO
Non-call reception Allowed by setting the number of calls to 0.
YES Manual reception setup
Setup for switching to automatic reception
NO
NO Number of calls to switch to automatic reception in manual reception mode
Dial-in
Answering machine connection
Answering connection
Reception mode time switch
NO
NO
NO
(2) Zoom reception
Reduction Reduction to regular size
Reduction between regular sizes
Enlargement
YES (ON/OFF by key operator program)
YES (by print condition setup of key operator program)
NO
(3) Memory reception function
Proxy reception
Compulsory memory reception
Only when output is disabled.
NO
(4) Received data override output
YES
(5) Transfer
Transfer destination registration YES (Registered by key operator program)
Transfer procedure YES (Operated with function menu)
(6) Specified number reception
Reception of only specified numbers allowed
Reception of specified numbers inhibited
(7) Confidential function
Confidential reception
NO
YES
Sender Sharp machine having confidential function only
Confidential box Registered up to 10 boxes
36 letters Confidential box name
Confidential ID code
May be set per confidential box
AR-FX4 OUTLINE/SPECIFICATIONS - 3
(8) Rotation reception
Paper is outputted by rotating 90 degrees to the set direction of paper in cassette
(9) Division reception
Division size When no paper for reception of long document
Division reception setup YES (by print condition setup of key operator program)
(10) Duplex reception
NO
(11) 2 in 1 reception
NO
(12) Polling (send request)
Polling
Resolution at send request
YES
Variable by soft SW.
Default: fine
(13) Turn around transmission
NO
7. Registration system
(1) Number registration
Speed dialing
Rapid key dialing
Group dialing
Number of items
Number of digits of other party’s number
Registered name
Searched letters
User tag classification
International communication mode setup
Transmission method
Number of items
Number of digits of other party’s number
Registered name
Searched letters
User tag classification
International communication mode setup
Transmission method
Registered key
Max. number of registration per group dialing
Registerable number
300 items
40 digits
36 letters
Up to 10 letters
NO
YES
Speed dialing key + (000 to 299) +
Start key
50 items
40 digits
36 letters
Up to half-size 10 letters
NO
YES
Rapid dialing key (01 – 50)
Rapid dialing key
100 items (The total number of registration is 150 items.)
Registered name
Searched letters
User tag classification
Transmission method
Numbers registered to speed dialing, rapid dialing, and numbers entered with 10-key
36 letters
Up to 10 letters
NO
Rapid dialing key
Program Number of items 9 items
Registerable item All items that can be set in transmission, except for time setup
Registered name
Call method
36 letters
By pressing program key
Change in setup after calling
YES
(2) Sender registration
Sender’s name 36 letters, registered with key operator program
Sender’s number 20 digits, registered with key operator program
(3) Polling (send request), bulletin board (remote transmission) allow number registration)
Send request allow number
System number
ID number
Registration of other party to which send request is made
System number registration
ID number registration
10 digits, 20 digits, registered by key operator program
Up to 1 number, registered in key operator program
Up to 10 items in 4 digits.
Registered by key operator program.
(4) Letter input
Input method
Letters allowed for input
Key entry
Half-size characters
(5) Registered data write
YES
Alphabet, Numerical figures,
Special characters, Codes
YES (Service tool. Dial registration can be made with PC.)
(6) Date/time adjustment
Registered by key operator program.
(7) Backup
Backup of registration in power failure
SRAM used, by built-in battery
8. Telephone function system
Handset
On-hook function
Reserve
Pause
NO
YES
NO
YES (1 to 15sec: Default 2sec, set by key operator program)
Telephone transmission in power failure
Sound volume adjustment
Call sound volume
Line monitor sound
No (However, external telephone transmission is allowed.)
YES (Set by key operator program to
Large/Medium/Small/No sound.)
YES (Set by key operator program to
Large/Medium/Small/No sound.)
On-hook sound YES (Set by key operator program to
Large/Medium/Small.)
Scan end sound
Communication end sound
Tone pulse switch
YES (Set by soft switch to Large/
Medium/Small/No sound.)
YES (Set by soft switch to Large/
Medium/Small/No sound.)
PULSE/TONE selection with key operator program.
YES External telephone connection
Remote reception switch
YES (Switch number is in 1 digit +
5
∗∗
∗∗
)
9. Memory system
Memory capacity Standard
Option
Memory content
(transmission reservation) confirmation
LCD display
Printout
2MB
Up to 8MB (+2MB/+4MB/+8MB)
YES
YES
Memory use status
Document data memory backup in power failure
YES (% display)
YES (Flash memory)
10. Additional information function for transmission
Page counter
Date printing
Cover paper function
Transmission message
Sender print function
Date/ display sequential switch
Cover paper item
Date
Receiver’s name
Receiver’s number
Sender’s name
Sender’s number
Display of number of documents transmitted
Transmission message
Print paper size
Regular message
User message
Sender’s number
Sender’s name
YES
YES (Year/month/day, Year in 4 digits)
NO
YES
YES
YES
YES
YES
YES
YES
A4 (AB series)
8.5 x 11 (Inch series)
CONFIDENTIAL/PLS.
DISTRIBUTE/URGENT/
PLS.
CALL BACK/IMPORTANT
NO
20 digits, registered with key operator program
36 letters
11. Additional print function when receiving
Index print YES (Set by key operator program)
AR-FX4 OUTLINE/SPECIFICATIONS - 4
12. Recording table system
(1) Communication record function
Communication record table size AB series A4 (Not output when paper greater than
A4 is not set.)
Communication record memory capacity
Communication record table
Number of items
Inch series
Letter (not output if size setting is not
Letter or larger)
50 items in total of transmission and reception
Max. 50 items for each of transmission and reception
(Total of transmission and reception is up to 50 items.)
Record table is outputted separately. If registration exceeds 50, the oldest one is deleted.
YES (2 times per day)
Time-specified communication table
Confidential reception check table
Time-specified output
Output when recording memory full
Output of individual department
Soft SW provided
YES (Communication time of each department is outputted as department management record table.)
Common with transmission record table
YES
(2) Communication result report function
Communication result table
(transmission)
(3) Report function
YES (Select Always print/in failure of transmission/no print. With key operator program)
Broadcast communication report
Communication result table
(reception)
Communication result table
(confidential reception)
Document content print in transmission error
YES (Select Always print/in failure of transmission/no print. With key operator program)
YES (Select Always print/in failure of transmission/no print. With key operator program)
YES (Select Always print no print. With key operator program)
YES (Some part of the first page is printed:
ON/OFF setup by key operator program.
Confidential transmission data are never printed.)
(4) Other report list
Rapid key dialing table
Telephone number table
Transmission message list
YES (Rapid key table)
Speed dialing table YES (Speed dialing table)
Group table YES (Group number table
YES (Table of searched letters in rapid key dialing, speed dialing, and group dialing in alphabetical order)
NO
YES
YES
ID/Senders list
Confidential ID table
Soft switch list
Memory image deletion table
YES
NO
13. Others
CSI transmission function
Department management
CSI transmission
Limitation on users in each department
Number of departments registered
Operation panel display
Automatic booting mode
Charge management function for each department
LCD
AR-FX4 OUTLINE/SPECIFICATIONS - 5
YES
YES
20 items
NO
19 letters x 5 lines
NO
[3] INSTALLATION PROCEDURE
1. Install of expansion kit
A. Parts included
2) Attach the fax key unit.
Connect the flat cable to the fax key unit, attach the fax key unit to the operation panel, and use the screw to fix it.
Close the front cover of the copier.
Fax key unit
Screw
Fax key unit: Fax PWB TEL/LIU PWB
Speaker unit: M3 golden screws:
2 pcs.
M3 screws with washer: 6 pcs.
Front cover
3) Remove the shielding plate and the left rear cabinet.
Remove the 5 fixing screws on the shilding plate and take off the shilding plate with inserting the flatblade screwdriver, etc.
Next, remove the 5 fixing screws on the left rear cabinet, and slide it backward to remove.
PWB spacers: 2 pcs.
Fax connector cover:
1 pcs.
Line cable: 1 pcs.
Supplied label:
1 sheet
Writing label: 1 sheet Installation manual:
1 sheet
(2)
(1)
Screws
Operation manuals:
2 pcs.
B. Installation
Turn off the main switch of the copier and then remove the power plug of the copier from the outlet.
1) Remove the fax dummy cover.
Open the front cover of the copier, remove the screw that fixes the fax dummy cover, and remove the fax dummy cover.
Fax dummy cover
Shielding plate
Left rear cabinet
Screws
4) Work the left rear cabinet.
Cut and remove the cut-out portion from the left rear cabinet using a tool such as nippers.
Be careful about the direction of the tool so that the cut surface is flat.
Cut-out portion
Screw
Front cover
AR-FX4 INSTALLATION PROCEDURE - 1
5) Attach the speaker.
Attach the speaker to the left rear cabinet using supplied two golden screws (M3).
M3 golden screws
8) Reattach the left rear cabinet.
1. Pass the speaker harness through the hole of the frame of the fax expansion PWB and connect it to the connector of the fax
PWB.
2. Fit the pawls of the left rear cabinet to the mounting portions of the main unit. Slide the cabinet toward the front of the main unit to attach it.
3. Fix the left rear cabinet with 2 screws.
4. Attach the supplied fax connector cover.
Speaker harness
Screw
1
3
Left rear cabinet
6) Attach the fax PWB.
Mount the two spacers on the fax PWB.
Next, insert the fax PWB connector into the connector on the expansion PWB, install with 4 M3 screws with washer.
M3 screws with washer
Fax PWB
2
4
3
Fax connector cover
Screw
Pawls
9) Reattach the shielding plate.
Fit the pawls of the shielding plate to the main unit and secure the plate using five screws.
Spacers
M3 screws with washer
7) Attach the TEL/LIU PWB.
Insert the TEL/LIU PWB connector into the fax PWB connector, attach 2 spacers on the TEL/LIU PWB, and attach the TEL/LIU
PWB with 2 M3 screws with washer.
Screws
TEL/LIU PWB
Spacers
M3 screws with washer
Shielding plate
Insert the power plug of the copier to the outlet and turn on the main switch. Then, carry out the following procedure.
10) Date/time setting
Press [SPECIAL FUNCTION] key on the operation panel, select
[KEY OPERATOR PROGRAM]. Input 5-digit Key Operator Code with 10-key, and select [FAX] in Mode Select.
Select [DEFAULT SETTING], [DATE/TIME SETTING], and input month/day/year in this order, and press [OK] to set.
Input hour/minute in this order, and press [OK] to set.
AR-FX4 INSTALLATION PROCEDURE - 2
11) Paste the label on the left rear cabinet of the copier.
Paste the FCC label to the position shown in the illustration.
In order to manifest the compliance with FCC Part 68 and IC CS-03, it is required to provide the machine with the FCC Registration Number (USA),
Ringer Equivalence (USA) and Ringer Equivalence (Canada).
After installing the FAX expansion kit in the machine, please put the registration label, packed with the kit, on the prescribed location.
3
FCC label
2. Mounting of additional memory
(AR-MM5, MM6, MM7)
• When mounting memory, turn off the main unit.
1) Remove the fax connector cover using a flatblade screwdriver or the like.
2) Insert the memory card securely so that the model name is on the rear side.
3) Reattach the fax connector cover.
• Turn on the main unit.
(When turning on the main unit just after expansion, the system check time will become longer due to memory initialization.)
4) Make certain that the memory was expanded by displaying SW list with SIM 66-21.
1)
3)
Fax connector cover
1)
2)
3)
Memory card
AR-FX4 INSTALLATION PROCEDURE - 3
[4] ADJUSTMENTS
Section
1 Density section
2 Communication section
1. Density section
Adjustment items
A FAX mode density adjustment (Overall mode)
B FAX mode density adjustment (Individual mode)
A Dial test
A. FAX mode density adjustment (Overall mode)
(<FAX mode> SIM 46-12)
1) Set the test chart (TPAP-2109SCZZ <CCITT #3 chart>) on the OC table as shown below, and close the OC cover.
Adjustment procedures
<FAX mode> SIM 46-12
<FAX mode> SIM 46-13 – 46-16
<FAX mode> SIM 66-13
B. FAX mode density adjustment (Individual mode)
(<FAX mode> SIM 46-13 – 16)
1) Set the test chart (TPAP-2109SCZZ <CCITT #3 chart>) on the OC table as shown below, and close the OC cover.
Glass holding plate
2) Switch to the FAX mode and execute SIM 46-12.
3) After warming up, shading is performed and the current density level is displayed on the lower two digits of the display section in standard and auto density mode.
4) Enter the set value with the 10-key to adjust the FAX image density.
5) Make a copy, and adjust so that the following adjustment specification is satisfied.
∗
When an adjustment is made in this mode, the exposure level for each communication mode and each density mode are automatically adjusted accordingly.
<Adjustment specifications>
Density mode
Auto
Resolution mode
SIM
Standard FAX mode
46-12
CCITT #3 chart output result
“3” is slightly copied.
Set value
The greater the set value is, the greater the density is, and vice versa.
Set range
0 – 99
Glass holding plate
2) Switch to the FAX mode and execute SIM 46-13 to 46-16 depending on the adjustment mode.
3) After warming up, shading is performed and the current density level is displayed on the lower two digits of the display section.
4) Enter the set value with the 10-key to adjust the FAX image density.
5) Make a copy, and adjust the density with the copy as a reference.
<Adjustment specifications>
Resolution mode
Density changeover
Standard Switched with the density select
Fine key.
Switched with the density select key.
Super fine Switched with the density select key.
Ultra fine Switched with the density select key.
SIM
FAX mode 46-
13
FAX mode 46-
14
FAX mode 46-
15
FAX mode 46-
16
Set value
The greater the set value is, the greater the density is, and vice versa.
Set range
0 – 99
AR-FX4 ADJUSTMENTS - 1
2. Communication section
Note: These items are factory adjusted when shipping according to
FCC standards. Therefore, do not change the setting in the market.
A. Dial test (<FAX mode> SIM 66-13)
(1) Dial pulse transmission test
1) Execute SIM 66-13 in FAX mode.
2) Execute the dial pulse mode according to the instructions on the
LCD display.
SELECT SIGNAL
1:PULSE 2:DTMF
3) Select the dial pulse.
SELECT PULSE
1:10PPS 2:20PPS
4) Set the make time.
INPUT MAKE TIME
(0-15) _
5) Select the dial to be transmitted.
Default: 0123456789
∗
#
(After deleting with the clear key, it can be set to any desired value.)
6) Transmission is started from the line.
SEND yyPPS xxm s
1:YES 2:NO
SENDING yyPPS xxm s
Dial pulse make time
10
PPS
20
PPS
SIM
FAX mode
66-13
Soft
SW
SW 67-
1 – 4
SW 67-
5 – 8
Initial value
40ms
(14)
Set value
SW set value: 0 – 15
Make time: 26 – 41ms
0ms 0 fixed
1ms step
(Binary input)
(2) DTMF signal transmission level adjustment
1) Execute SIM 66-13 in the FAX mode.
2) Execute the DTMF mode according to the instructions on the LCD display.
SELECT SIGNAL
1:PULSE 2:DTMF
3) Select the signal transmission level.
The signal transmission level is classified into two groups: the high group, and the low group.
Transmission can be made with either of default and the soft SW set value.
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
4) The transmission level can be set when the following menu is displayed on the LCD. (et value 1 = 0.5dB change)
INPUT VALUE
(0-15) _
(This value is returned to the original value when the simulation mode is canceled.)
5) Select the dial signal to be transmitted.
Default: 0123456789
∗
#
(After deleting with the clear key, it can be set to any desired value.)
AR-FX4 ADJUSTMENTS - 2
6) Start transmission from the line.
H:xx L:yy
1:YES 2:NO xx: High group soft SW set value yy: Low group soft SW set value
SENDING DTMF
SIM
DTMF transmission level
High group
Low group
(FAX mode) 66-
13
(Test only)
Soft
SW
SW 53-
1 – 4
SW 53-
5 – 8
Initial value
Set value
3.5dB SW set value:
(7) 0 – 15
3.5dB
Transmission
(7) level: 0 – 7.5dB
0.5ms step
(Binary input)
[5] SIMULATION
1. Entering the simulation mode/cancel of simulation mode
Procedure
1 Simulation mode selection
Key operation
#
→
INTERRUPT
→
C
→
INTERRUPT
10-key (Input main code)
→
START
10-key (Input sub code)
→
START
2 Main code selection
3 Sub code selection
4
Selection of the mode and item
5 Start simulation operation
6
Returns to the sub code selection.
Simulation mode clear
10-key and
↑ ↓
OK or START
INTERRUPT
CA
• Selection of the main code and the sub code is set with the [START] key.
• There are two or more screens, the adjustment "Current page/Max.
page" is displayed. Press [
↑
] key (previous page) or [
↓
] key to select a screen.
2. Simulation code list
Code
Main Sub
8 13
22
24
26
46
48
50
66
14
15
11
10
1
60
12
13 to
16
8
3
4
1
2
9
10
8
9
6
7
10
11
13
17
21
30
32
34
Function
Used to check and adjust the operation of the developing bias voltage in FAX mode and the control circuit.
Used to check and adjust the operation of the main charger grid voltage (high mode) in FAX mode and the control circuit.
Used to check and adjust the operation of the main charger grid voltage (low mode) in FAX mode and the control circuit.
FAX related counter display
FAX related counter clear
Used to set options. (This simulation is used to make option setting when an option is installed.)
Used to set enable/disable of the FAX mode key when FAX is not installed. (When FAX is installed, the FAX mode is enabled regardless of this setup.)
FAX exposure level adjustment (batch)
FAX exposure level adjustment (individual)
FAX magnification ratio adjustment (read)
FAX magnification ratio adjustment (print)
FAX auto reduction magnification ratio (print).
FAX lead edge adjustment (read)
FAX lead edge adjustment (print)
FAX related soft SW setting
Initial set for the value of the FAX soft SW
FAX PWB memory check
Signal send mode
Printing the confidential password
Image data print
Image data memory clear
300bps signals send
Send test and adjustment of the dial pulse and
DTMF signal.
DTMF signal send
FAX information print
TEL/LIU state change recognition
Receive data check
Communication time measurement display
Code
Main Sub
66
37
38
50
Function
Speaker sound volume adjustment
Time setting/check
The FAST area of SRAM is cleared.
3. Details
8
8-13
Purpose
Function
(Purpose)
Section
Adjustment/Operation test/check
Used to check and adjust the operation of the developing bias voltage in FAX mode and the control circuit.
Image process (Photoconductor/Developping/
Transfer/Cleaning)
Developer/Toner hopper
Operation/procedure
Enter the adjustment value and press the [OK] key, and output operation is performed for 30sec.
(Initial screen) (Executing screen)
Sim8-13 DV BIAS FAX
FAX 426
Sim8-13 DV BIAS FAX
FAX 426
EXEC [200-550] 4260 EXEC [200-550] 426
Setting range 200-550
Default 426
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd number is entered the entered odd number + 1 is displayed after pressing [OK] key.
8-14
Purpose
Function
(Purpose)
Section
Adjustment/Operation test/check
Used to check and adjust the operation of the main charger grid voltage (high mode) in FAX mode and the control circuit.
Image process (Photoconductor/Developping/
Transfer/Cleaning)
Photo conductor
Operation/procedure
Enter the adjustment value and press the [OK] key, and output operation is performed for 30sec.
The input value is in the increment of –25V.
(Initial screen) (Executing screen)
Sim8-14 MHV(H) FAX
FAX 5
Sim8-14 MHV(H) FAX
FAX 5
EXEC [ 1- 8] 5
Setting range 1-8
Default 5
EXEC [ 1- 8] 5
AR-FX4 SIMULATION - 1
NO.
Set value
1 480
2 505
Grid High Grid Low
–480V –350V
–505V –375V
3
4
530
555
5 580
6 605
7 630
–530V
–555V
–580V
–605V
–630V
8 655 –655V
–400V
–425V
–450V
–475V
–500V
–525V
*1. The negative value of the set value corresponds to the grid high output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the grid low voltage is –350V.
8-15
Purpose
Function
(Purpose)
Section
Adjustment/Operation test/check
Used to check and adjust the operation of the main charger grid voltage (low mode) in FAX mode and the control circuit.
Image process (Photoconductor/Developping/
Transfer/Cleaning)
Photo conductor
Operation/procedure
Enter the adjustment value and press the [OK] key, and output operation is performed for 30sec.
(Initial screen) (Executing screen)
Sim8-15 MHV(L) FAX
FAX 5
Sim8-15 MHV(L) FAX
FAX 5
EXEC [ 1- 8] 5 EXEC [ 1- 8] 5
Setting range 1-8
Default 5
NO.
Set value
1 480
2 505
3 530
Grid High Grid Low
–480V –350V
–505V
–530V
–375V
–400V
4
5
555
580
6 605
7 630
–555V
–580V
–605V
–630V
8 655 –655V
–425V
–450V
–475V
–500V
–525V
*1. The negative value of the set value corresponds to the grid high output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the grid low voltage is –350V.
22
22-11
Purpose
Function
(Purpose)
Adjustment/Setting/Check
FAX related counter display
Operation/procedure
The current counter value (number of send/receive pages) of the FAX send/receive counter and the accumulated reception time and the print counter are displayed.
Note: Executable only when the FAX is installed.
24
24-10
Purpose
Function
(Purpose)
Adjustment/Setting/Check
FAX related counter clear
Operation/procedure
The current counter value (number of send/receive pages) of the FAX send/receive counter and the accumulated reception time and the print counter are cleared to 0.
Note: Executable only when the FAX is installed.
26
26-1
Purpose
Function
(Purpose)
Item
Setting
Used to set options. (This simulation is used to make option setting when an option is installed.)
Specifications Option
Operation/procedure
Set the job separator.
Sim26-1 OPTION SET.
JOB SEPARATOR 0
(0:NONE
1:JOB SEPARATOR)
[ 0- 1] 0
Set value
0
1
Connection option
None (default)
Job separator provided.
26-60
Purpose
Function
(Purpose)
Item
Setting
Used to set enable/disable of the FAX mode key when
FAX is not installed. (When FAX is installed, the FAX mode is enabled regardless of this setup.)
Operation
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
This setup varies in connection with SIM 26-6 (Destination setup).
Sim26-60 FAX KEY
FAX KEY SETTING 0
(0:ON 1:OFF)
[ 0- 1] 0
Display items
0:ON
Content
Setting range
0-1
Default
JAPAN,
SEC, SECL,
SUK, SCA
Others
0 1
1:OFF
Effective (The message with FAX uninstalled is displayed.)
Disable (Error Beep)
AR-FX4 SIMULATION - 2
46
46-12
Purpose
Function
(Purpose)
Adjustment
FAX exposure level adjustment (batch)
Operation/procedure
Shading is performed to turn on the copy LED.
The current exposure value of "Normal character, Auto exposure" mode is displayed.
Enter an adjustment value of 2 digits with the 10-key and press the
START key, and the entered value will be set to all the modes and the self print will be made in the normal size.
Exposure adjustment value table
Mode
STD
(Standard character)
Fine
(Small character)
S-fine
(Fine)
U-fine
(Super fine)
AE
Auto
Manual
Auto
Manual
Auto
Manual
Auto
Manual
Auto
Manual
Auto
Manual
Auto
Manual
Auto
Manual
Photo
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Exposure adjustment
–
Individual adjustment
When initializing each data: 50
Note: Executable only when the FAX is installed.
enable
(46-13 to 16)
46-13 to 16
Purpose
Function
(Purpose)
Adjustment
FAX exposure level adjustment (individual)
Operation/procedure
The FAX exposure level can be adjusted separately for each mode by specifying a sub code. Since selection of Auto/Manual and Photo ON/
OFF is allowed separately for each mode, adjustments of 14 patterns in total can be made.
(Refer to 46-12, "Exposure adjustment table".)
Sub code
13
14
15
16
Mode
STD (normal character)
Fine (small character)
S-fine (super fine)
U-fine (super fine)
Shading is performed to turn on the copy LED.
The current exposure value of the selected mode is displayed.
Enter the 2-digit adjustment value with the 10-key pad and push
START key. The entered value is set for the specified mode, and the self print is made with the same magnification ratio for the mode.
Note: Executable only when the FAX is installed.
48
48-8
Purpose
Function
(Purpose)
Related soft
SW
Adjustment
FAX magnification ratio adjustment (read)
SW76-1 to 8, SW77-1 to 8
Operation/procedure
Adjust and set FAX document read magnification ratio, read and print the document.
Adjustment magnification ratio
Adjustment range
OC read main scanning magnification ratio
OC read sub scanning magnification ratio
SPF read main scanning magnification ratio
SPF read sub scanning magnification ratio
1 – 128 –
255%
Note: Executable only when the FAX is installed.
Adjustment unit
0.1% increment
48-9
Purpose
Adjustment
Function
(Purpose)
FAX magnification ratio adjustment (print)
Related soft SW
SW78-1 to 8, SW79-1 to 8
Operation/procedure
After the adjustment/setting of FAX print magnification ratio, read and print the document.
Adjustment magnification ratio
Main scanning magnification ratio
Sub scanning magnification ratio
Adjustment range
1 – 128 –
255%
Note: Executable only when the FAX is installed.
Adjustment unit
0.1% increment
48-10
Purpose
Adjustment
Function
(Purpose)
FAX auto reduction magnification ratio (print).
Related soft SW
SW25-1 to 4
Operation/procedure
Set the FAX auto reduction magnification ratio (0 to 15%).
Note:Executable only when the FAX is installed.
50
50-8
The adjustments on the machine side must have been normally completed.
Purpose
Function
(Purpose)
Adjustment
FAX lead edge adjustment (read)
Related soft SW
SW44-1 to 4, SW44-5 to 8
SW45-1 to 4, SW45-5 to 8
Operation/procedure
Adjust and set FAX document read lead edge position, read and print the document.
AR-FX4 SIMULATION - 3
66
B
A
OC read
Read area
C
Adjustment position
D
F
E
SPF read
Read area
Adjustment range
A OC read lead edge position
B OC read left edge position
C OC read rear edge position
D OC read right edge position
43 – 50 – 57 lines
43 – 50 – 57 dots
43 – 50 – 57 lines
43 – 50 – 57 dots
E SPF read lead edge position 43 – 50 – 57 lines
F SPF read left edge position 43 – 50 – 57 dots
G SPF read rear edge position 43 – 50 – 57 lines
H SPF read right edge position 43 – 50 – 57 dots
Note: Executable only when the FAX is installed.
G
Adjustment unit
8 lines
8 dots
8 lines
8 dots
8 lines
8 dots
8 lines
8 dots
H
66-3
Purpose
Function
(Purpose)
Adjustment/Setting/Check
FAX PWB memory check
Operation/procedure
Read/write can be checked for FAX PWB memory.
The check result is displayed separately for each memory.
1.
Memory to be checked
DRAM
SRAM
Flash ROM Program area
Memory area
SUM check only
Option memory The memory size follows the automatically detected value.
PAGE
2.
Detailed procedure
1 "55H" is written to all the addresses of each memory, and the address data are read in sequence to check that they were properly written.
2 "AAH" is written to all the addresses of each memory, and the address data are read in sequence to check that they were properly written.
3 "00H" is written to all the addresses of each memory, and the address data are read in sequence to check that they were properly written.
4 Perform checks 1 - 3 sequentially. If there is no abnormality, it is
"OK." If there is any abnormality, "NG" is notified to the error address.
5 After completion of check, the memory is returned to the initial state.
(CPU is not reset)
Interruption cannot be made during operation.
Note: Executable only when the FAX is installed.
50-9
Purpose
Adjustment
Function
(Purpose)
FAX lead edge adjustment (print)
Related soft SW
SW74-1 to 4, SW75-5 to 8
Operation/procedure
After the adjustment/setting of FAX print lead edge position, read and print the document.
66-1
Adjustment position
A Lead edge position
B Left edge position
Purpose
Function
(Purpose)
Adjustment range
43 – 50 – 57 lines
43 – 50 – 57 dots
Note: Executable only when the FAX is installed.
Adjustment/Setting/Check
FAX related soft SW setting
Adjustment unit
16 lines
16 dots
Operation/procedure
Display FAX software SW on LCD, and set/change those with 10-key.
Note: Executable only when the FAX is installed.
66-2
Purpose
Function
(Purpose)
Adjustment/Setting/Check
Initial set for the value of the FAX soft SW
Operation/procedure
Used to clear the FAX-related soft switches except for the line signal adjustment value and the machine adjustment value and to set default values (which differ depending on the country code separately entered.)
Note: Executable only when the FAX is installed.
AR-FX4 SIMULATION - 4
66-4
Purpose
Function
(Purpose)
Related soft
SW
Adjustment/Setting/Check
Signal send mode
SW5-5 to 8 (signals send level)
SW23-1 to 4 (RBT ON time)
SW23-5 to 8 (RBT OFF time)
SW43-1 to 5 (DTMF signal send time)
Operation/procedure
By setting the message No., the signal is sent to the line and the speaker of the body. (The signal is continuously sent until the interruption command is provided by pressing the [BACK] key.)
The signal send level can be selected from 0dB or the soft SW set value. However, the level setup is not required for 01, 31 - 35, the selection may does not appear. After completion of the mode, the signal send level is returned to the soft SW set value before execution of the mode.
01
26
Signal number
27, 28, 30
31
32
Tone signal
Send signal
Signal not send
7EH Flag signal
Pseudo-ringer sound
([ON HOOK] key ON)
Voice message (no sound)
Under the state where the ring back tone can be sent to the line, keep the sound composition IC volume to
0.
Send level
Selection menu
None
Yes
Yes
None
None
33
Signal number
Send signal
34
35
Ring back tone (no sound)
Under the state where the ring back tone can be sent to the line, keep the G/A volume to 0.
Dial pulse (make)
Maintain the make state with keeping the condition to be able to send to the dial pulse line.
Dial pulse (break)
Maintain the break state with keeping the condition to be able to send to the dial pulse line.
FFH Other than the above
Note: Executable only when the FAX is installed.
Send level
Selection menu
None
1: 0dB
2: Soft SW
1: 0dB
2: Soft SW
Yes
66-6
Purpose
Function
(Purpose)
Adjustment/Setting/Check
Printing the confidential password
Operation/procedure
The confidential ID table (confidential BOX numbers, confidential BOX names, and confidential password) is printed.
The confidential data of My company mode is printed separately.
Note: Executable only when the FAX is installed.
66-7
Purpose
Function
(Purpose)
Adjustment/Setting/Check
Print the screen memory contents
Operation/procedure
Used to input all image data (including confidential reception data, remote send image, not-sent image) stored in image memory of the
FAX section.
The output image is remained even after outputting.
Note: Executable only when the FAX is installed.
66-10
Purpose
Function
(Purpose)
Adjustment/Setting/Check
Image data memory clear
Operation/procedure
Used to clear all image data (including confidential reception data) stored in image memory of the FAX section.
The management table is also cleared (initialized) at the same time.
Note: Executable only when the FAX is installed.
66-11
Purpose
Function
(Purpose)
Adjustment/Setting/Check
300bps signals send
Operation/procedure
By setting the signal number, the specified signal is delivered to the line at the speed of 300bps. (The signal is continuously sent until the interruption command is provided by pressing the [BACK] key.)
The signal send level can be selected from 0dB or the soft SW set value.
The signal send level is returned to the soft SW set value before execution of the mode after completion of the mode.
Number
1
2
3
Signal
No signal (CML ON)
11111
11110
Number
4
5
6
Note: Executable only when the FAX is installed.
Signal
00000
010101
00001
66-13
Purpose
Function
(Purpose)
Adjustment/Setting/Check
Send test and adjustment of the dial pulse and
DTMF signal.
Related soft SW
SW53-1 to 4 (DTMF high group end level)
SW53-5 to 8 (DTMF low group send level)
SW67-1 to 4 (DP 10PPS make time)
SW67-5 to 8 (DP 10PPS make time)
Operation/procedure
The send test of dial pulse and DTMF signal is performed and the make time adjustment of dial pulse and the DTMF signal send level adjustment are performed if necessary.
1.
Dial pulse (10pps) send test
2.
Dial pulse (20pps) send test
• Used to set the make time. By performing the test, the registered dial pulse of max. 100 digits can be sent from the line.
• When "*" and "#" are included in the registered dial number, they are disregarded and the number is not processed as a dial.
• The make time set in the dial test is written into the corresponding soft SW.
• Default: 1 2 3 4 5 6 7 8 9 0
Operate the [
←
] [
→
] key in DP dial selection menu to switch.
(Time before pulse delivery can be changed as 2sec
→
4sec
→
8sec.)
3.
DTMF signal send test
• Set the signal send level to 0dB or the soft SW set value.
Used to set the high level group and the low level group of DTMF signal send level. By executing the test, DTMF signal is sent from the line to a recorded dial number of max. 100 digits.
• The high group/low group value of the DTMF signal send level set in the dial test is written into the corresponding soft SW.
• Default: 1 2 3 4 5 6 7 8 9 * 0 #
In the PB dial select menu, press [
←
][
→
] keys to select.
Pressing the [CLEAR] key during the operation clears the input value and returns to the value input menu.
• Max. 100 digits can be assigned to each dial (0 - 9, *, #). While the default value is displayed at first, a desired value can be entered and the entered value is stored on the FAX side until the menu is canceled.
• After completion of the mode, the signal send level is returned to the soft SW set value before execution of the mode.
Make time
Break time
DTMF signal adjustment
1ms for input value of 1. Adjust so that the dial pulse make rate is within 33±3%. (For North America,
40±3%.)
Dial pulse make rate =
Make time / (Make time + Break time)
It is obtained from the formula below and automatically set.
PPS = 1000 / (make time + break time)
The signal send levels are classified into the high group and the low group. The send level is 0.5dB for each 1 of input value.
Note: Executable only when the FAX is installed.
AR-FX4 SIMULATION - 5
66-17
Purpose
Function
(Purpose)
Adjustment/Setting/Check
DTMF signal send
Related soft SW
SW53-1 to 4 (DTMF high group end level)
SW53-5 to 8 (DTMF low group send level)
Operation/procedure
Set the signal send level to 0dB or the soft SW set value, and specify one dial to be delivered to.
The DTMF signal of the specified dial number is delivered until the interruption command is provided by pressing the [BACK] key.) When another dial number is specified during delivery of the signal, the new dial number is delivered.
The signal send level is returned to the soft SW set value before execution of the mode after completion of the mode.
Note: Executable only when the FAX is installed.
66-21
Purpose
Function
(Purpose)
Adjustment/Setting/Check
FAX information print
Operation/procedure
The following FAX information is printed.
Print information
1 User switch list
2 Soft SW list
3 Dump list
4 System error
Details
5 Protocol monitor
Used to print the system error log (error number and time). For this operation, the system error log is always stored as the ring buffer in the SRAM 256byte area.
Regardless of soft SW19-1 status, the protocol monitor of the preceding communication is printed. (Printing is allowed at any time before starting the next communication.) For this operation, the protocol monitor of one communication is always buffered.
Note: Executable only when the FAX is installed.
66-30
Purpose
Function
(Purpose)
Adjustment/Setting/Check
Recognize TEL/LIU state change.
Operation/procedure
When the relay state of the polarity reverse relay, the external telephone hook switch is changed, the content of change is displayed regardless of the soft SW setup. The display of change is kept until an interruption command is supplied by pressing the [BACK] key.
Check signal
HS2
HS1
RHS
EXHS
Notification contents
Signal low
—
Signal high
—
—
ON
ON
Note: Executable only when the FAX is installed.
—
OFF
OFF
66-32
Purpose
Adjustment/Setting/Check
Function
(Purpose)
Receive data check
Operation/procedure
The data received from the line are checked to insure that the following reception data are identical to the judgment data. If identical, "OK" is notified. If not, "NG."
A judgment is made according to the reception start data. Continuous coincidence is required.
Receive speed
Receive data
Number of judgment data
300bps
00
100
Note: Executable only when the FAX is installed.
66-34
Purpose
Function
(Purpose)
Adjustment/Setting/Check
Communication time measurement display
Related soft SW
SW10-1
Operation/procedure
The send/receive test is performed, and the time required for send/ receive of the image data in the test is measured and displayed.
Setup on the user side when executing communication
Measuring range
Communication means
Picture quality
Density
ECM
Sender information
: Memory send
: Normal Character
: Lighter
: ON
: OFF
Send From flag reception before sending of image data until sending of RCP frame
Receive From flag reception before reception of image data until reception of RCP frame
Mode when measuring Used to make communication not in a simulation process but in the normal screen and measure the time.
How to check the time Enter the simulation for communication time check and check the time.
Measuring unit msec
When there are two or more send/receive operations of image data in one communication, only the time of the last send/receive data near the end is measured.
Note: Executable only when the FAX is installed.
66-37
Purpose
Function
(Purpose)
Adjustment/Setting/Check
Speaker sound volume adjustment
Related soft SW
SW 86-1, 2 (call sound)
SW 85-1, 2 (line monitor sound)
SW 84-1, 2 (on hook)
SW 88-1, 2 (read end sound)
SW 89-1, 2 (communication end sound)
SW 87-1, 2 (DTMF send sound)
SW75-1, 2 (send end sound length)
SW75-3, 4 (receive end sound length)
AR-FX4 SIMULATION - 6
Operation/procedure
The following test sound is delivered to the line and the speaker to adjust the sound kind and volume.
The send level to the line is the set value of soft SW.
The set values of the selected sound kind and volume are written to each soft SW.
1.
Sound kinds pattern
Sound kinds
(Test sound)
Sound volume set value
0 1 2
1 Call sound
2 Lline monitor sound
(Test sound :
Communication signal sound)
3 On hook
(Test sound :
Communication signal sound)
4 Read complete sound
5 Communication end sound
6 DTMF signal send sound
NS
NS
Setting
Disable
NS
NS
NS
S
S
S
S
S
S
NS=No Sound S=Small M=Medium L=Large
2.
Sound volume pattern
M
M
M
M
M
M
3
L
L
L
L
L
L
Sound volume
Pattern
01 to 35
01 to 35
01 to 35
01 to 35
01 to 35
01 to 35
10
11
12
13
06
07
08
09
Sound volume
01
02
03
04
05
14
15
16
17
18
19
S
S
S
S
S
S
1 2 3 4 5 6 7
S M L
S M
S M
VR set value
L
L
L S M
S M
S
S
S
S
M
M
M
M
L
L
L
L
L
S M L
S M
S M
S M
M L
M
M
L
L
M L
M L
M L
L
L
L
S=Small M=Medium L=Large
Note: Executable only when the FAX is installed.
29
30
31
32
25
26
27
28
Sound volume
20
21
22
23
24
33
34
35
VR set value
1 2 3 4 5 6 7
S M L
S
S
M
M
L
L
S
S
S
M L
M L
M L
S
S
S
S M L
S M
S M
L
L
M L
M L
M L
S M L
S M
S M
L
L
S M L
66-38
Purpose
Adjustment/Setting/Check
Function
(Purpose)
Time setting/check
Operation/procedure
Read/write the time (year, month, day, min., sec.) on RTC of FAX
PWB.
Note: Executable only when the FAX is installed.
66-50
Purpose
Function
(Purpose)
Adjustment/Setting/Check
The FAST area of SRAM is cleared.
Operation/procedure
Only the SRAM area where data related to FAST are stored is cleared.
Note: Executable only when the FAX is installed.
AR-FX4 SIMULATION - 7
[6] SOFT SWITCH DESCRIPTIONS
1. Quick reference of FAX soft SW setup change
Large item
Dial (calling)
Reception
Medium item
Remote party calling inhibited
G3/SG3
Switch content
Pause time
Dial calling signal
DTMF related items
CSI transmission
Max. reception length
Key operator
Initial setup
Initial setup
NO
NO
Soft SW No.
Purpose of use
SW 38-1 – 4 When dial inhibited/erroneous dial
SW 41-1, 2 When dial inhibited
SW 53-1 – 4 When dial inhibited in PB (PBX/FAX service, etc.)
SW 53-5 – 8 When dial inhibited in PB (PBX/FAX service, etc.)
Redialing
Reception
(receiving call)
External telephone
Setup of external telephone
Remote switch number
Remote switch setup
Communication General
Transmission
Pulse (10PPS)
Signal detection Busy tone detection
Busy tone detection
Dial tone detection
When error
When error
When busy
When busy
When CI detection inhibited
Recall interval
Number of times of recall Send function setup
Recall interval
Number of times of recall Send function setup
CI detection
CI signal OFF detection time
YES/NO
NO
NO
NO
NO
Send function setup
Send function setup
NO
NO
Initial setup
SG3
G3/SG3
SG3
G3
Input of 2-digit number
YES/NO
Transmission level
JBIG mode
V34 symbol rate
DIS reception confirmation
Line equalizer
V34 transmission speed
NO
Initial setup
NO
NO
NO
V34 mode function setup NO
NO SW 58-1 – 6 When SG3 communication errors occur frequently
Rapid key/speed dial, etc. SW 6-8 When an error occurs in phase B
NO
Rapid key/speed dial, etc.
Manual transmission V34 NO
NO
SW 43-1 – 5 When dial inhibited in PB (PBX/FAX service, etc.)
SW 67-1 – 4 When dial inhibited with pulse
SW 7-3
SW 4-5 – 8
SW 40-5 – 8
SW 12-6, 7
SW 16-2
When busy tone detection inhibited
SW 15-1 – 3 When busy tone detection error
SW 7-4
SW 4-1 – 4 When transmission errors occur frequently
SW 40-1 – 4
When line is busy frequently
No reception
SW 55-1 – 7 No reception
When connecting external telephone
SW 2-5 – 8 When remote switch is erroneously detected
SW 8-5 When remote switch is erroneously detected
SW 5-5 – 8 When remote machine cannot receive signals at a proper level.
SW 10-8
SW 52-7
When an error occurs in JBIG mode
When SG3 communication errors occur frequently
SW 5-1, 2 It is set depending on the distance with the station when a communication error occurs.
When an error occurs in SG3 communication.
SW 52-6
SW 6-5
When SG3 communication error occurs in
FAX service, etc.
When V29 communication error occurs.
V29 no-modulation carrier
Modem transmission speed
RTN reception error
Rapid/speed dial, etc.
NO
SW 15-5 – 8 For certain/uncertain destinations
SW 52-5 When the result is OK though RTN is received.
NO
NO When receiving a document of 1m or more length
SG3
Proxy reception
Prevention against EQM dissipation
V34 reception speed
NO
NO
NO
G3 Countermeasure for echo in reception
NO
Reception modem speed NO
EYE-Q check only NO
When line is in bad condition and errors occur frequently.
When fall-down frequently occurs in SG3 communication.
When an error occurs in phase B of reception.
SW 7-7, 8 When line is in bad condition and fall-back or errors occur frequently.
SW 72-1 Change in detection method of training error
AR-FX4 SOFT SWITCH DESCRIPTIONS - 1
Large item Medium item Switch content
Reception print Paper selection Sub scan length judgment
NO
Key operator
Output condition setup Reception function setup
Soft SW No.
Purpose of use
When print is not made on selected paper.
Index
Automatic reduction print Reception function setup
Magnification ratio in automatic reduction
Index print setup
NO
Rotation reception print NO
Reception size setup Reception function setup
Reception function setup
To make divided print instead of reduction print
When reduction print is not made.
When reduction print is not made on a fixed size paper.
When rotation print is not made.
Reception capacity is indicated on the transmission machine.
When an index is added to received data.
2. Soft switch list
∗
∗
When outside the set range, the default value is automatically set.
Never change the soft switch setup which are inhibited to use.
SW
NO.
Data
No.
Item
1 Size specification
Switch selection and contents of functions
2
Bit No.
Centimeter size
Inch size
Conforms to the machine information.
Conforms to the machine information.
1 2
0 0
1 0
0 1
1 1
S
W
1
3 Inhibited to use
4 Auto/Manual default setup
1: Manual reception 0: Automatic reception
S
W
2
S
W
3
7
8
5 Send request protection 1: Not protected
6 Reduction send mode 1: Normal
1: Not print 7 Contents of send document are printed in memory send error
8 Inhibited to use
3
4
1 Inhibited to use
2
5 Remote selection
6 number setup
Binary input
Bit No.
Set range
1 Density default setup
2
3
Bit No.
Auto
Light
Slightly light
Medium
Slightly dark
Dark 4
5
6 Image quality priority selection
7
8
Bit No.
Normal
Fine
Super fine
Ultra fine
Not used
Fine + half-tone
Super fine + half-tone
Ultra fine + half-tone
0: Protected
0: Reduction
0: Print
5 6 7 8
0 to 9
1 2 3 4 5
0 0 0 0 0
1 0 0 0 0
0 1 0 0 0
0 0 1 0 0
0 0 0 1 0
0 0 0 0 1
6 7 8
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
Initial value Remark
Conforms to the machine information.
Automatic reception
0
1
When set to conformity to the machine information, if machine information is uncertain, set to centimeter size.
0
0
Manual reception can be set only when external telephone is connected.
Protected
Reduction
0
0
5
0
0
0
0
0
0
0 When a value
1 outside the set
0 range is set, the initial value is
1 set.
0
Auto
0
0
0
0
0
Normal 0
0
AR-FX4 SOFT SWITCH DESCRIPTIONS - 2
SW
NO.
Data
No.
Item
1 Recall interval in
2 communication error
3
4
S
W
4
Switch selection and contents of functions
Binary input
Bit No.
Set range
5 Recall interval in busy Binary input
6 Bit No.
7
8
Set range
1 2 3
0 to 15min
4
0: Immediate recall after disconnection of line
5 6 7
1 to 15min
8
1 2
0 0
0 1
1 0
1 1
S
W
5
1
2
Line equivalent unit [km] Bit No.
No Filter
1.8km
3.6km
7.2km
3 Inhibited to use
4
5 Signal send level
6
7
8
1 ECM
2 CED signal send
3 CSI transmission
4 DIS reception confirmation in G3 send
Binary input
Bit No.
Set range
1: YES
1: YES
1: YES
1: 2 times
5 6
–5 to –20dBm
0: NO
0: NO
0: NO
7 8
0: Once in NFS reception
2 times in DIS reception
S
W
6
0: NO
0: 13sec
0: 75ms
S
W
7
5 Non-modulation carrier in V.29 send
6 EOL detection timer
7 Countermeasure for echo in reception
(CED tone send interval)
8 Countermeasure for echo in transmission
(After reception of DIS, hold time up to signal send is set.)
1 MH fixed
1: YES
1: 25sec
1: 500ms
1: 500ms
1: YES
2 Dial tone detection
3 Busy tone detection
4 Dial tone monitoring time
1: YES
1: YES
1: 10sec
5 Inhibited to use
6 Max. length of reception 1: No limit
7 Modem speed in reception fixed
Bit No.
No fixing
8
V.29-9600BPS
V.27ter-4800BPS
V.17-14400BPS
0: 200ms
0: NO (depending on the other party’s machine)
0: NO
0: NO
0: 5sec
0: 1.5m
7 8
0 0
0 1
1 0
1 1
Initial value Remark
1min
3min
No Filter
–12dBm
YES
YES
YES
Once in NFS reception, 2 times in
DIS reception
0
1
1
1
1
1
0
1
0
1
0
0
0
1
0 When a value
0 outside the set
1 range is set, the
1 initial value is set.
0
0
When a value outside the set range is set, the initial value is set.
NO
13sec
0
0
75ms
200ms
NO
NO
YES
5sec
1.5m
No fixing
0
0
0
0
1
0
0
0
0
0
AR-FX4 SOFT SWITCH DESCRIPTIONS - 3
SW
NO.
S
W
8
S
W
9
S
W
10
S
W
11
S
W
12
Data
No.
Item
1 Memory transmission/ direct transmission default setup
2 Proxy reception
3 Printing the content of transmitted document in normal memory transmission
4 Judgment of system No. in bulletin transmission
5 Remote reception indication
6 Inhibited to use
1: YES
1: Not print
1: Allow
1: YES
Switch selection and contents of functions
1: Direct transmission 0: Memory transmission
0: NO
0: Print
0: Inhibit
0: NO
7
8
1 Print of total communication time and total pages
2 Inhibited to use
1: YES 0: NO
3 Quick memory transmission
4 Yes/No of SUB capacity in reception
1: Allow
1: NO
5 F-code relay broadcast function
6 F-code confidential reception function
7 Yes/No of SEP capacity in reception
8 Yes/No of reception
PWD capacity
1: Inhibit
1: Inhibit
1: NO
1: Send without password
1 Measurement of communication time
(image)
2 Sender’s telephone number registration
1: YES
1: Inhibit
0: Inhibit
0: YES
0: Allow
0: Allow
0: YES
0: Disconnection of line with
DCN
0: NO
0: Allow
0: Disconnection of line with
DCN
0: NO
3 Yes/No of reception SID capacity
4 SDT signal detection
1: Send without password
1: YES
5 Inhibited to use
6
7 ECM MMR mode
8 ECM JBIG mode
3
4
1 Inhibited to use
2
1: YES
1: YES
7
8
5
6
3
4
1 Inhibited to use
2
5
6 CI detection
7
Bit No.
4 sine wave
3 sine wave
2 sine wave
0: NO
0: NO
6
0
7
0 0
1 0
1
1 1
8 Inhibited to use
Initial value
Memory transmission 0
YES 1
Not print
Inhibit
YES
YES
1
Allow
YES
Allow
Allow 0
YES 0
Disconnection of line with DCN
0
YES 1
1
1
1
0
0
0
1
0
1
0
Remark
Allow 0
Disconnection of line with DCN
NO
0
YES
YES
4 sine wave
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
When a value outside the set range is set, the initial value is set.
0
AR-FX4 SOFT SWITCH DESCRIPTIONS - 4
SW
NO.
S
W
13
S
W
14
S
W
15
S
W
16
3
4
5
6
Data
No.
Item
1 Inhibited to use
2
Switch selection and contents of functions
7 Relay data output
8 Relay broadcast function
1 V.34 mode sending
2 speed
3
4
5 V.34 mode reception
6 speed
1: YES
1: Allow
Binary input
Bit No.
Sending speed =
2400(bps) x N
7
8
1 Lower limit of speaker sound detection time
2 Upper limit of speaker sound detection time
Binary input
Bit No.
Reception speed =
2400(bps) x N
1: 350ms
1: 650ms
3 Lower limit 2 of speaker sound detection time
4 Inhibited to use
5 Modem speed
(V.33 mode or below)
6
1: 150ms
Bit No.
V.27 2400bps
V.29 9600bps
V.27 4800bps
7
8
V.29 7200bps
V.33 14.4kbps
V.33 12.0kbps
V.17 9600bps
V.17 12.0kbps
V.17 7200bps
V.17 14.4kbps
1 Inhibited to use
2 External telephone connection
3 Inhibited to use
4
5 Rotation transmission selection
(11 x 8.5
→
8.5 x 11)
6 Rotation transmission selection (A4
→
A4R)
7 Rotation transmission selection (B5R
→
B5)
8 Rotation transmission selection (A5
→
A5R)
1 Paper selection priority sequence
2 Output condition setup
1: YES
1: YES
1: YES
1: YES
1: YES
1: Width priority
3
Bit No.
Reduction allowed
Division allowed
0: NO
0: Inhibit
1
Others
0: NO
0: NO
0: NO
0: NO
0: NO
3
0: 250ms
0: 750ms
4
When N=0, 2400bps.
When N=15, 33600bps.
5
When N=0, 2400bps.
When N=15, 33600bps.
0: Follows SW15-1.
5
0
0
0
0
0
0
1
1
1
2
0
1
2
6
6
0
0
0
0
1
1
0
0
0
3
0
0
7
7
0
0
1
1
0
1
0
1
1
8
8
0
1
0
1
0
0
1
0
1
0: Area priority
S
W
17
7
8
4 Inhibited to use
5
6
Initial value
YES
Allow
33600bps
33600bps
250ms
750ms
Follows SW15-1.
0
0
0
1
1
1
1
0
1
0
1
1
0
0
0
0
0
0
1
0
1
V.17 14.4kbps
0
0
Remark
0
YES
YES
0
1
0
0
1
YES
YES
YES
1
1
1
Area priority
Reduction allowed
0
0
1
1
1
1
0
0
When a value outside the set range is set, the initial value is set.
AR-FX4 SOFT SWITCH DESCRIPTIONS - 5
SW
NO.
S
W
18
S
W
19
S
W
20
S
W
21
Data
No.
Item
1 Inhibited to use
2
3 Reception size
4 specification
(Indicates reception capacity.)
5 11 inch reception capacity setup
6 Output method in A3 width reception (Inch series)
7 Output method in A4 width reception (Inch series)
8 Override print setup
1
Protocol monitor
2 Inhibited to use
3 Output only in protocol monitor error
Bit No.
3 4
By the attached cassette 0 0
B4 (A4/B4) 0 1
A4
A3 (A4/B4/A3)
1: 255mm or 215mm
1: 297mm width
1: Data of 8.5 inch width is printed
1: Override print allowed
1: YES
1: YES
4 Protocol monitor save 1: Save
5 Inhibited to use
1: YES 6 Recording table automatic print
7 Time specification 1 of communication record table
1: Allow
8 Time specification 2 of communication record table
1 Line sound monitor range
1: Allow
2
Bit No.
OFF
Up to NSF signal send/ receive
All
1: YES
Switch selection and contents of functions
1: Not output
1 0
1 1
0: 303mm or 255mm or
215mm
0: 11 inch width
0: Data of 210mm width is printed
0: Override print inhibited
0: NO
0: NO
0: Disable
0: NO
0: Inhibit
0: Inhibit
1 2
0 0
0 1
1 0
1 1
0: NO
0: Output
3 Line monitor display
4 Data output specification in communication error during reception
5 Receivable memory capacity
6 Memory over during reception
7 Flag-adrs timer setup
(V.21-FSK)
8
1: 64Kbyte
1: Output
Bit No.
6sec
15sec
30sec
120sec
Binary input
Bit No.
Set range
0: 128Kbyte
0: Not output
7
0
0 1
1 0
1 1
1
8
0
2 3 4
0 to 255sec
5 6 7 8
6
7
8
1 Interval between
2 completion of
3 communication and the
4 next call
5
Initial value
0
By the attached cassette
0
303mm or 255mm or
215mm
0
11 inch width
0
8.5 inch width print
YES
Inhibit
128Kbyte
Output
0
1
0
0
0
0
0
0
1
0
0
0
1
0
1
Override print allowed 1
NO 0
0
NO
Save
0
1
0
1
0
Remark
Inhibit 0
Up to NSF signal send/ receive
0
When a value outside the set range is set, the initial value is set.
1
NO 0
Output 0
6sec
1sec
AR-FX4 SOFT SWITCH DESCRIPTIONS - 6
SW
NO.
S
W
22
S
W
23
S
W
24
Data
No.
Item
1 Inhibited to use
2
3
4
5
6
7
8
1 Inhibited to use
2
3
4
5
6
7
8
1 Image capacity at send request
2
Switch selection and contents of functions
Bit No.
Ultra fine
Super fine
Fine
Normal
1: Refuge specified number reception
1: Refuge specified number reception
1
0
0
1
1
2
0
1
0
1
0: Ignore specified number reception
0: Ignore specified number reception
S
W
25
S
W
26
S
W
27
3 Specified number reception
4 Specified number reception when manual reception
5 Inhibited to use
6 Document output setup in reception
7 Inhibited to use
8 Automatic reduction print
1 Automatic reduction
2 rate setup
3
6
7
4
5 Inhibited to use
2
3
8
1 Inhibited to use
6
7
4
5
8
1 Inhibited to use
2 Recording paper tray selection
(Tray 1)
3 Recording paper tray selection
(Tray 2)
4 Recording paper tray selection
(Tray 3)
5 Recording paper tray selection
(Tray 4)
6 Inhibited to use
7
8
1: Collective output after completion of reception.
1: Allow
Binary input
Bit No.
Set range
1: ON
1: ON
1: ON
1: ON
0: Output after reception of every page
0: Inhibit
1 2
0: OFF
0: OFF
0: OFF
0: OFF
3
0 to 15%
4
Initial value
0
Ultra fine
0
Ignore specified number reception
0
Ignore specified number reception
0
0
Output after reception of every page
0
0
Allow
6%
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
1
1
ON 1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
ON
ON
ON
1
1
1
0
0
0
Remark
AR-FX4 SOFT SWITCH DESCRIPTIONS - 7
SW
NO.
S
W
28
S
W
29
S
W
30
Data
No.
Item
1 Inhibited to use
2
3
4
5
6
7
8
1 Inhibited to use
2
3
4
5 Setup of number of
6 times of call rings
7
8
1 Report output when canceling
2 Inhibited to use
3 Rotation print
4 Department management
5 Default data, sender print
6 Department name notification
7 Date/sender print position setup
8 Report output (in confidential reception)
1 Report output (in transmission)
1: Output
1: Allow
1: Allow
1: ON
1: ON
1: Print
Switch selection and contents of functions
Binary input
Bit No.
Set range
1: Inside of document
5 6 7
0: Inhibit
0: Inhibit
8
0 to 9 times
0: Not output
0: OFF
0: OFF
0: Outside of document
0: Not print
S
W
31
2
3 Report output
4
5
6
(In broadcast, sequential send request, and relay broadcast)
Report output (in reception)
Bit No.
Print inhibited
All print
Only when transmission is failed.
1 2
0 0
0 1
1 0
Bit No.
Print inhibited
All print
Only the address to which transmission is failed
1 1
3 4
0 0
0 1
1 0
Bit No.
Print inhibited
All print
Only in error
1 1
5 6
0 0
0 1
1 0
1 1
7 Inhibited to use
8
1 Distinctive ring
S
W
32
2
3
4
Bit No.
OFF
Standard/ON
Pattern1
Pattern2
Pattern3
Pattern4
Pattern5
1 2 3 4
0 0 0 0
0 0 0 1
1 0 0 0
0 1 0 0
1 1 0 0
0 0 1 0
1 0 1 0
5 Inhibited to use
6 Index print setup
7 Inhibited to use
8
1: Print 0: Not print
Initial value
2 times
Not output
Allow
Inhibit
ON
OFF 0
Outside of document 0
Print 1
0
1
1
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
1
Only when transmission is failed.
1
0
Remark
0
All print
1
Print inhibited
OFF
Not print
0
0
0
0
0
0
0
1
0
0
0
Other than
U.S.A., Canda,:
OFF (fixed)
Australia: ON/
OFF only
0
AR-FX4 SOFT SWITCH DESCRIPTIONS - 8
SW
NO.
S
W
33
S
W
34
Data
No.
Item
1 Page number print setup
2 Inhibited to use
3
4
5
6
7
8
1 Inhibited to use
7
8
5
6
2
3
4
1 Cover function default setup
2 Inhibited to use
3 CI delete max. OFF time
S
W
35
4
S
W
36
S
W
37
S
W
38
5 Inhibited to use
6
7
2
3
8
1 Inhibited to use
6
7
4
5
2
3
8
1 Inhibited to use
6
7
4
5
2
3
8
1 Pause time setup
4
1: YES
1: YES
Bit No.
5sec
Switch selection and contents of functions
10sec
15sec
20sec
Binary input
Bit No.
Set range
5 Inhibited to use
6
7 Transfer function
8 Inhibited to use
1 Call time setup in
2 automatic transmission
3
(T0 timer setup)
1: Allow
Binary input
Bit No.
Set range
0: NO
0: NO
1
1 to 15sec
0: Inhibit
1
2
2
3
3
30 to 60sec
5sec unit
4
S
W
39
3 4
0 0
0 1
1 0
1 1
7
8
4 Inhibited to use
5
6
AR-FX4 SOFT SWITCH DESCRIPTIONS - 9
Initial value
YES
NO
10sec
2sec
Inhibit
45sec
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Remark
1
0
0
0
0
0
0
1
0
1
0
0
0
1
0
1
0
0
0
0
1
0
0
0
1
0 When a value
0 outside the set
1 range is set, the initial value is
0 set.
0
0
0
0
0 When a value
1 outside the set range is set, the
1 initial value is set.
1
SW
NO.
Data
No.
Item
1 Number of times of
2 recall in error
3
4
S
W
40
7
8
5 Number of times of
6 recall in busy
1 Tone/Pulse default setup
2
3
Telephone line menu
Switch selection and contents of functions
Binary input
Bit No.
Set range
1 2 3 4
0 to 1 times
Binary input
Bit No.
Set range
Bit No.
10PPS
20PPS
TONE
1: Inhibit
5
1
0
0
1
1
6
2
0
1
0
1
7
0: Allow
8
0 to 14 times
S
W
41
4 Maintenance system
5 F.A.S.T mode 1: YES 0: NO
S
W
42
S
W
43
S
W
44
6 Sequence of year/ month/day in LCD, report, and sender
7 record
Bit No.
Year/Month/Day
Month/Day/Year
Day/Month/Year
8 Time display format
1
Direct send recall Allow/
Inhibit
2 Inhibited to use
3
4 Manual/Auto reception auto swiching
5 Number of auto switch
6 calls of manual
7 reception
→
auto
8 reception
1: am/pm
1: Allow
1: Allow
Binary input
Bit No.
Set range
2
3
1 DTMF signal send time Binary input
Bit No.
Set range
4
5
6 Maintenance cycle
7
Bit No.
50K
25K
12.5K
8
1 Scan effective image
2
3
4 area (OC)
Main scan
Left edge image loss
5K
Others
1: –
Binary input
Bit No.
Set range
5 Scan effective image
6 area (SPF)
7
Main scan
8
Left edge image loss
1: –
Binary input
Bit No.
Set range
6 7
0 0
0 1
1 0
1 1
0: 24H
0: Inhibit
0: Inhibit
5 6 7 8
1 to 9
1 2 3
10ms unit
6 7 8
0 0 1
0 1 0
0 1 1
1 0 0
FREE
0: +
4
60 to 310ms
2 3 4
0 to ±56 dots
8 dot interval
0: +
6 7 8
0 to ±56 dots
8 dot interval
5
Initial value
1 times
2 times
TONE
Allow
NO
Month/Day/Year am/pm
Allow
Inhibit
9 times
110ms
50K
+
+0 dot
+
+0 dot
0
1
0
0
0
0
0
0
0
0
Remark
1
0
0
0 When a value
0
0 outside the set range is set, the
1 initial value is set.
0 When a value
0 outside the set
1 range is set, the initial value is
0 set.
1
0
When a value outside the set range is set, the initial value is set.
0
Japan, U.S.A.,
Canada: Fixed to “Allow”
0
0
0
1
Fixed to NO for other than
U.S.A. and
Canada.
When a value outside the set range is set, the initial value is set.
1
0
1 When a value
0 outside the set
0 range is set, the
1 initial value is set.
0 When a value
1 outside the set
0 range is set, the
1 initial value is
1 set.
0
AR-FX4 SOFT SWITCH DESCRIPTIONS - 10
SW
NO.
S
W
45
S
W
46
S
W
47
S
W
48
S
W
49
S
W
50
S
W
51
Data
No.
Item
1 Scan effective image
2
3 area (OC)
Main scan
4
Right edge image loss
5 Scan effective image
6 area (SPF)
7
8
Main scan
Right edge image loss
1: –
Binary input
Switch selection and contents of functions
0: +
Bit No.
Set range
2 3 4
0 to ±56 dots
8 dot interval
0: + 1: –
Binary input
Bit No.
Set range
6 7 8
0 to ±56 dots
8 dot interval
1 Inhibited to use
2
3 Priority in the day of week
4 Inhibited to use
7
8
5 Daylight saving tive
6 Inhibited to use
1 Time specification print
2
1 (O’clock) in the
3 communication report
4 table
7
8
5
6 Inhibited to use
1 Time specification print
2
1 (min) in the
3 communication report
4 table
5
6
7 Inhibited to use
8
1 Time specification print
2
2 (O’clock) in the
3 communication report
4 table
7
8
5
6 Inhibited to use
1 Time specification print
2
2 (min) in the
3 communication report
4 table
5
6
7 Inhibited to use
8
3
4
1 Inhibited to use
2
5
6 CED detection time
7 Busy tone detection cycle
8
1: YES
1: Allow
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
1: 500ms
Bit No.
2puls
4puls
6puls
10puls
0: NO
0: Inhibit
1
00 to 23 o’clock
1 2
0: 1000ms
7 8
0 0
0 1
1 0
1 1
3 4
00 to 59min
1
00 to 23 o’clock
1
2
2
2
3
3
3
4
4
4
00 to 59min
5
5
5
5
6
6
AR-FX4 SOFT SWITCH DESCRIPTIONS - 11
Initial value
+
+0 dot
+
+0 dot
NO
Inhibit
0 o’clock
0 min
0 o’clock
0 min
1000ms
2puls
Remark
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 When a value
0 outside the set
0 range is set, the
0 initial value is
0 set.
0
0
0
0 When a value
0 outside the set
0 range is set, the
0 initial value is
0 set.
0
0
0
0 When a value
0 outside the set
0 range is set, the
0 initial value is
0 set.
0
0
0
0
0
0
0
0
0
0 When a value
0 outside the set
0 range is set, the
0 initial value is
0 set.
0
0
0
SW
NO.
S
W
52
S
W
53
S
W
54
Data
No.
1
2
Busy tone detection level
Item
3 ERR frame reception operation
4 Inhibited to use
5 Error process in RTN reception
6 V.34 mode function in manual communication
7 V.34 mode function
8 V.34 control channel communication speed
1 DTMF send level
2
(High group) setup
3
4
5 DTMF send level
6
(Low group) setup
7
8
1 Scan effective image
2 area (OC)
3
Sub scan
4 lead edge image loss
5 Scan effective image
6 area (SPF)
7
Sub scan
8 lead edge image loss
Bit No.
–43dB
–35dB
–33dB
–30dB
1: Continues process.
1: Not error
1: ON
1: ON
1: 2400bps
Switch selection and contents of functions
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
1: –
Binary input
Bit No.
Set range
1: –
Binary input
Bit No.
Set range
1
0
0 1
1 0
1
0: Not continue process.
(Error)
0: Error
0: OFF
0: OFF
0: 1200bps
1
2
0
1
2 3
0 to 7.5db
4
0.5dB interval
5 6 7 8
0 to 7.5db
0.5dB interval
0: +
2 3 4
0 to ±56 line
8 line interval
0: +
6 7 8
0 to ±56 line
8 line interval
S
W
55
1 CI signal OFF detection
2 enable time
3
Binary input
Bit No.
Set range
6
7
4
5
8 EQM judgment threshold value
1: Loose
1 2 3
10ms unit
0: Tight
4
0 to 1270ms
5 6 7
S
W
56
S
W
57
6
7
4
5
1 Inhibited to use
2
3
6
7
8
4
5
2
3
8
1 Inhibited to use
Initial value Remark
0
–43dB
0
Not continue process.
(Error)
0
0
Error 0
ON
ON
1200bps
3.5db
3.5db
+
+0 line
+
+0 line
1200ms
Tight
0
1
1
1
0
0
1
1
0
0
1
0
0
1
1
0
0
0
0
0
0
1
0
1
1
1
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
Disable when
EQM Judge
Value is SRAM
AR-FX4 SOFT SWITCH DESCRIPTIONS - 12
SW
NO.
S
W
58
S
W
59
S
W
60
S
W
61
S
W
62
S
W
63
Data
No.
Item
1 V.34 3429 (baud)
Rate Mask
2 V.34 3200 (baud)
Rate Mask
3 V.34 3000 (baud)
Rate Mask
4 V.34 2800 (baud)
Rate Mask
5 Inhibited to use
6 V.34 2400 (baud)
Rate Mask
7 Inhibited to use
5
6
3
4
8
1 Inhibited to use
2
7
8
1 Inhibited to use
2
3
4
5 Countermeasures against V.34 communication error
(reception)
(Phase 2 error retry setup)
6 Countermeasures against V.34 communication error
(transmission)
(Phase 2 error retry setup)
5
6
3
4
7 Inhibited to use
8
1 Inhibited to use
2
5
6
3
4
7
8
1 Inhibited to use
2
5
6
3
4
7
8
7
8
1 Inhibited to use
2
1: YES
1: YES
Switch selection and contents of functions
1: supported
1: supported
1: supported
1: supported
1: supported
0: not supported
0: not supported
0: not supported
0: not supported
0: not supported
0: NO
0: NO
AR-FX4 SOFT SWITCH DESCRIPTIONS - 13
NO
0
1
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
1
0
1
0
1
1
0
1
1
Initial value supported supported supported supported supported
1
1
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
Remark
NO
0
SW
NO.
S
W
64
S
W
65
S
W
66
S
W
67
S
W
68
S
W
69
S
W
70
3
4
5 Inhibited to use
6
7
8
1 Inhibited to use
2
3
4
5 T1 timer setup
6
7
8
1 Inhibited to use
2
4
5
6
7
8
5
6
3
4
7
8
1 Inhibited to use
2
3
Data
No.
Item
1 Inhibited to use
2
3
4
5
6
7
8
1 Inhibited to use
2
3
4
5
6
7
8
1 Inhibited to use
2
5
6
3
4
7
8
1 Setup of make rate
2
(10PPS)
Switch selection and contents of functions
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
1
26 to 41ms
1ms interval
5
2
6
3
7
4
8
15 to 90sec
5sec interval
Initial value
40ms
40sec
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
1
0
1
1
0
0
0
0
0
0
0
1
0
1
1
0
1
0
0
1
0
0
0
0
1
0
0
0
1
1
0
0
0
1
0
0
0
0
1
Remark
AR-FX4 SOFT SWITCH DESCRIPTIONS - 14
SW
NO.
Data
No.
Item
1 Dial ringing wait time
S
W
71
S
W
72
S
W
73
S
W
74
S
W
75
Switch selection and contents of functions Initial value Remark
2
Bit No.
3.5sec
4sec
5sec
6sec
1 2
0 0
0 1
1 0
1 1
3.5sec
0
0
3 Inhibited to use
4
5
6
7 Silent detection level
8
1 EYE-Q check
Bit No.
– 43dBm
– 40dBm
– 39dBm
1: EYE-Q check only
7 8
0 0
0 1
–43dBm
1 0
0: 0 reception & EYE-Q check 0 reception & EYE-Q check
4
5
2 Inhibited to use
3
6
7
8
1 Inhibited to use
4
5
2
3
6
7 DIS reception process selection in reception
8
1 Print lead edge
2 adjustment (Lead edge
3 adjustment)
4
5 Print lead edge
6
7
8
1 Transmission end
2 adjustment (Rear edge adjustment) sound
(Buzzer sound length) setup
3 Reception end sound
4
(Buzzer sound length) setup
5 Print lead edge
6
7
8 adjustment (Left edge)
Bit No.
7 8
Command resend by judging that echo has been received 0 0
Line disconnection by judging as improper DIS 0 1
1 0 Polled send when there is polled document with DIS reception. In other cases, command resend by judging that echo has been received.
Polled send when there is polled document with DIS reception, command resend when judgement that transmitter has received echo, in other cases, shut down the line as ellegal DIS.
1 1
0: + 1: –
Binary input
Bit No.
Set range
2 3
16 line interval
0: +
4
0 to ±112 line
1: –
Binary input
Bit No.
Set range
Bit No.
3sec
1sec
Silent
6
16 line interval
1 2
0 0
0
1
7
1
0
1 1
3 4
8
0 to ±112 line
Bit No.
3sec
1sec
Silent
0
0
1
0
1
0
1 1
0: + 1: –
Binary input
Bit No.
Set range
6 7 8
0 to ±112 line
16 line interval
Command resend by judging that echo has been received
+
48 line
+
48 line
3sec
3sec
+
48 line
0
0
0
1
1
1
0
0
1
0
0
1
0
0
1
0
0
0
0
0
1
0
0
0
0
0
0
0
1
0
1
1
0
0
When outside the set range, the initial value is set.
0
Communi-cation error sound is generated even in silent setup
0
0
Communi-cation error sound is generated even in silent setup
0
AR-FX4 SOFT SWITCH DESCRIPTIONS - 15
SW
NO.
S
W
76
S
W
77
S
W
78
S
W
79
S
W
80
S
W
81
Data
No.
Item
4
5
1 Scan magnification ratio
2
3 adjustment OC
(main scan)
6
7
8
Switch selection and contents of functions
1: –
Binary input
Bit No.
Set range
0: +
2 3 4 5
0 to ±12.7%
0.1% interval
6 7 8
0: + 1 Scan magnification ratio
2 adjustment OC
3
(sub scan)
4
1: –
Binary input
Bit No.
Set range
7
8
5
6
1 Print magnification
2 ration adjustment (main
3 scan)
4
1: –
Binary input
Bit No.
Set range
2
2
3
0: +
3
4
4
5
0 to ±12.7%
0.1% interval
5
0 to ±12.7%
0.1% interval
6
6
7
7
8
8
7
8
5
6
1 Print magnification
2 ration adjustment (sub
3 scan)
4
7
8
5
6
1 Scan effective image
2 area (OC)
3
Sub scan
4
Rear edge image loss
5 Scan effective image
6 area (SPF)
7
Sub scan
8
Rear edge image loss
1: –
Binary input
1: –
Bit No.
Set range
Binary input
Bit No.
Set range
1: –
Binary input
Bit No.
Set range
0: +
2 3
0 to ±56 line
0: +
4
4
5
0 to ±12.7%
0.1% interval
0: +
2
8 line interval
6
3
7 8
0 to 28 line
2 line interval
0 = 14 line
6 7 8
3
4
1 Destination information Binary input
2 Bit No.
7
8
5 Language information Binary input
6 Bit No.
1
5
2
6
3
1: U.S.A.
2: Canada
7
1: English
4
8
S
W
82
6
7
8
4
5
1 Scan magnification ratio
2 adjustment SPF
3
(main scan)
1: –
Binary input
Bit No.
Set range
0: +
2 3 4 5
0 to ±12.7%
0.1% interval
6 7 8
Initial value
+
0%
+
0%
+
0%
+
0%
+
+0 line
+
+14 line
U.S.A.: 0 0 0 1
Canada: 0 0 1 0
English: 0 0 0 1
+
0%
Remark
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0 For English, the
0 proper character
0 is determined by destination
1 information.
0
AR-FX4 SOFT SWITCH DESCRIPTIONS - 16
SW
NO.
S
W
83
S
W
84
S
W
85
S
W
86
S
W
87
S
W
88
Data
No.
Item
4
5
1 Scan magnification ratio
2
3 adjustment SPF
(sub scan)
2
3
4
5
6
7
6
7
8
1 On-hook speaker volume
On-hook pattern number
8
1 Line monitor speaker volume
1: –
Binary input
Bit No.
Set range
Bit No.
Not used
Small
Medium
Large
Switch selection and contents of functions
Binary input
Bit No.
Set range
Bit No.
Silent
Small
0: +
2 3
0 to ±12.7%
0.1% interval
1
0
2
0
0 1
1 0
1 1
3
1
4
2
0 0
0 1
1 0
1 1
4
5
5
6
6
7
7
8
8
Pattern number 1 to 35
2
5
6
3 Line monitor pattern
4 number
Medium
Large
Binary input
Bit No.
Set range
7
8
1 Ringing volume
4
5
Bit No.
Silent
Small
Medium 2
Large
3 Ringing pattern number Binary input
Bit No.
Set range
3 4
Pattern number 1 to 35
1
0
0
1
1
3
2
0
1
0
1
4
5
5
6
6
7
7
8
8
Pattern number 1 to 35
6
7
8
1 Speaker volume in
DTMF send
2
3
4
5
6
Pattern number in
DTMF send
7
8
1 Speaker volume at scanner scan end
2
Bit No.
Silent
Small
Medium
Large
Binary input
Bit No.
Set range
Bit No.
Silent
Small
Medium
Large
Binary input
Bit No.
Set range
1
0 0
0 1
1 0
1 1
3
Pattern number 1 to 35
1
0
0 1
1 0
1 1
3
2
4
2
0
4
5
5
6
6
7
7
8
8
Pattern number 1 to 35
6
7
8
3 Pattern number in
4 scanner scanning
5
AR-FX4 SOFT SWITCH DESCRIPTIONS - 17
Initial value
+
0%
0
0
0
0
0
0
0
0
1
Medium
21
0
1
0
1
0
1
0
1
Medium
21
0
0
1
0
1
0
1
1
Medium
21
0
1
0
1
0
1
0
1
Medium
21
0
0
1
0
1
0
1
1
Medium
21
0
1
0
1
0
1
0
Remark
SW
NO.
Data
No.
Item
1 Speaker volume of communication end sound
2
S
W
89
S
W
90
S
W
91
S
W
92
S
W
93
S
W
94
S
W
95
6
7
4
5
2
3
8
1 Inhibited to use
6
7
4
5
2
3
8
1 Inhibited to use
6
7
4
5
8
2
3
8
1 Inhibited to use
6
7
8
3 Pattern number of
4 communication end
5 sound
6
7
4
5
1 Inhibited to use
2
3
6
7
4
5
2
3
8
1 Inhibited to use
6
7
4
5
2
3
8
1 Inhibited to use
Bit No.
Silent
Small
Medium
Large
Binary input
Bit No.
Set range
Switch selection and contents of functions
1 2
0 0
0 1
1 0
1 1
3 4 5 6 7 8
Pattern number 1 to 35
Initial value
Medium
21
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
1
0
1
0
1
Remark
AR-FX4 SOFT SWITCH DESCRIPTIONS - 18
SW
NO.
S
W
96
S
W
97
4
5
6
7
8
Data
No.
Item
1 Inhibited to use
2
3
4
5
6
7
8
1 Inhibited to use
2
3
3. Soft switch descriptions
SW1 No.1, No.2 Size specification
Used to set inch series or AB series for recording paper when printing received documents.
There is normally no need to change from "Depends on the machine information."
SW1 No.3 Inhibited to use
SW1 No.4 Auto/Manual default setup
Used to select Auto/Manual reception mode when turning on the power. (When no external telephone is connected, do not select Manual. However, setup is possible and reception can be made by onhook.)
When set to 1, manual reception.
When set to 0, auto reception.
Default: 0 (auto reception)
SW1 No.5 Send request protection
Used to set YES/NO of the confidential protection function (inhibition of transmission to an erroneous party). Confidential protection is performed by collating the number registered in this machine and that in the other party’s machine. (Sender’s telephone number
←→
Send request allow number, System number
←→
ID number)
When set to 1, protection is not made.
When set to 0, protection is made.
Default: 0 (protection enable)
SW1 No.6 Reduction send mode
Used to set whether the transmitted document is received in reduction size or both ends of recording paper are cut when the transmitted document width is greater than the recording paper width.
When set to 1, both ends are cut without reduction and transmitted.
When set to 0, it is reduced and transmitted.
Default: 0 (Reduction transmission)
SW1 No.7 Contents of send document are printed in memory send error
Used to set Print/Not print part of the sent document in the transmission result table in case of a memory transmission error.
When set to 1, the transmitted document is not printed on the transmission result table.
When set to 0, the transmitted document is printed on the transmission result table.
Default: 0 (Print transmitted documents)
Switch selection and contents of functions Initial value Remark
0
0
0
0
1
1
0
0
1
0
1
0
1
0
0
0
SW1 No.8 Inhibited to use
SW2 No.1 – No.4 Inhibited to use
SW2 No.5 – No.8 Remote selection number setup
Used to set the number by binary input for remote switch reception from an external telephone. "**" in a remote switch number (X**) is fixed.
When 10 or greater value is entered, the operations will be the same as setup of 5.
Default: Setup of 5 as 0101
SW3 No.1 – No.5 Density default setup
Used to set the default setup of density of the operation panel.
SW3 No.6 – No.8 Image quality priority selection
Used to set the initial value of image selection when scanning a document.
When set to 100, the operations are the same as the normal mode.
Default: 000 (Normal mode)
SW4 No.1 – No.4 Recall interval in communication error
Used to set recall interval after disconnection of communication due to a communication error in memory transmission.
The set range is 0 to 15 min in the increment of 1 min by binary input.
When set to 0, recall is made immediately after disconnection.
However, the time interval set by SW21 (Interval between the end of a communication and the next call) is taken.
Default: 0001 (1 min)
SW4 No.5 – No.8 Recall interval in busy
Used to set recall interval after disconnection of communication due to the busy state of the other party or no response.
Can be set in the range of 1 – 15min by increment of 1min by binary input.
When set to 0 min, it is the same as setup of 3 min.
Default: 0 0 1 1 (3 min)
SW5 No.1, No.2 Line equivalent unit [km]
Used to set the modem filter coefficient.
SW5 No.3, No.4 Inhibited to use
SW5 No.5 – No.8 Signal send level
Used to set the attenuation quantity of signal send level from the modem. The actual output level to the line pin is further attenuated by
8dBm. (When set to 2, the actual level on the line is about –10dBm.)
Default: 0 1 1 1 (–12dBm)
AR-FX4 SOFT SWITCH DESCRIPTIONS - 19
SW6 No.1 ECM
Used to set whether ECM (Error Correction Mode) is performed or not.
When, however, SW52-7 (V.34 mode function) is set to OFF, or when
SW52-7 (V.34 mode function is set to ON and the transmission is not the super G3 transmission, ECM Disable setup is effective. This is because the ECM function is indispensable in a transmission other than super G3 transmission in V.34 mode and the other party machine may perform checking. With SW52-7 (V.34 mode function) is ON and this reception function is disabled.
When set to 1, ECM is enabled.
When set to 0, ECM is disabled.
Default: 1 (ECM enabled)
SW6 No.2 CED signal send
Used to set whether CED signal is sent or not. This setup is effective only when SW52-7 (V.34 mode function) is off. This is because V.34
mode requires sending of ANSam signal.
When set to 1, CED (ANSam) signal is sent.
When set to 0, CED (ANSam) signal is not sent.
Default: 1, CED (ANSam) signal is sent.
SW6 No.3 CSI transmission
CSI signal includes the telephone number registered as sender’s number. Used to set whether this signal is sent or not.
When set to 1, CSI signal is sent.
When set to 0, CSI signal is not sent.
Default: 1 (CSI signal is sent.)
SW6 No.4 DIS reception confirmation in G3 send
Used to set whether DIS reception is checked or not in G3 mode.
When set to 1, DIS reception is always checked twice.
When set to 0, NSF/DIS reception is checked once, or DIS reception without NSF is checked twice.
Default: 0 (NSF reception is checked once, DIS without NSF is checked twice.)
SW6 No.5 Non-modulation carrier in V.29 send
Used to set whether non-modulation carriers are sent or not in V.29
transmission.
When set to 1, non-modulated carrier is sent.
When set to 0, non-modulated carrier is not sent.
Default: 0 (Non-modulated carrier is not sent.)
SW6 No.6 EOL detection timer
Used to set the detection timer of EOL (End Of Life) when Phase-C reception.
When set to 1, the timer is set to 25sec.
When set to 0, the timer is set to 13sec.
Default: 0 (13sec)
SW6 No.7 Countermeasures for echo in reception (CED tone send interval)
Used to select ON/OFF of countermeasures against echo.
An interval of 500ms is inserted before DIS transmission.
Default: 0 (75ms)
SW6 No.8 Countermeasure for echo in transmission
(After reception of DIS, hold time up to signal send is set.)
An interval of 500ms is inserted before DCS transmission.
Default: 0 (200ms)
SW7 No.1 MH fixed
Used to fix the image data compression method in communication.
Normal setting
When set to 0, automatic selection of MH/MR/MMR is performed according to the other party machine’s capacity.
When set to 1, MH fixed. This is effective when communication is made only with MH machine or when images are disturbed due to poor conditions of the line.
When SW52-7 (V.34 mode function) is OFF or when SW52-7 (V.34
mode function) is ON in transmission, MH fixing is enabled.
This is because the MMR function is indispensable in V.34 mode and the other party machine checks that. When SW52-7 (V.34 mode function) is ON in reception, this function is disabled.
SW7 No.2 Dial tone detection
Used to set whether dial tone detection is performed or not in auto dial ringing.
"1": YES
"0": NO
When set to YES and dial tone is not detected, dial is not performed.
Default: 0 (NO)
SW7 No.3 Busy tone detection
Used to set whether busy tone signal is detected or not in ringing.
When set to 1, busy tone is detected.
When set to 0, busy tone is not detected.
Default: 1 (Busy tone is detected.)
SW7 No.4 Dial tone monitoring time
Used to set dial tone monitoring time when detecting dial tone.
"1": 10sec
"0": 5sec
Default: 0 (5 sec)
SW7 No.5 Inhibited to use
SW7 No.6 Max. length of reception
Used to set the length of reception when long document is sent from the other party.
When set to 1, reception is made without limitations.
When set to 0, reception is terminated after 1.5m reception.
Default: 0 (Reception is terminated after receiving 1.5m.)
SW7 No.7, No.8 Modem speed in reception fixed
Used to set the start speed of reception procedure when receiving from an other party other than V.34.
bit 7 8
0 0 : No fixing
0 1 : V.29-9600BPS
1 0 : V.27ter-4800BPS
1 1 : V.17-14400BPS
When set to "no fixing," the operations are the same as V.17-
14400BPS.
The above four setups are possible. The reception procedure is started at the set communication speed.
Default: 0 0 (no fixing) Reception is made at the proper communication speed.
SW8 No.1 Memory transmission/direct transmission default setup
Used to select memory transmission or direct transmission when the power is turned on and when time out is cleared.
When set to 1, direct transmission is selected when the power is turned on and the time out is cleared.
When set to 0, memory transmission is selected when the power is turned on and the time out is cleared.
Default: 0 (Memory transmission)
SW8 No.2 Proxy reception
When set to 1, auto reception is accepted under the following conditions to perform proxy reception.
(1) No recording paper or jam
(2) Remaining image memory capacity is 128KB or 64KB or above.
(3) The number of memory reception (max. 50 items) and the number of pages do not exceed the limit.
When set to 0, automatic reception is not allowed without recording paper or in case of a jam.
Default: 1 (YES)
AR-FX4 SOFT SWITCH DESCRIPTIONS - 20
SW8 No.3 Printing the content of transmitted document in normal memory transmission
Used to set whether transmitted images are printed on the communication result table or not when the communication result table is printed after normal completion of memory transmission.
"1": The transmitted document is not printed.
"0": The transmitted document is printed.
Default: 1 (Not printed.)
SW8 No.4 Judgment of system No. in bulletin transmission
Used to set whether the condition of coincidence between the system number of this machine and that of the other party machine is employed as a criterion to judge whether to allow bulletin transmission by receiving polling transmission from the other party machine made by our company.
"1": When the system number of the other party machine made by our company coincide with the system number of this machine, polling is allowed.
"0": Though the system number of the other party machine made by our company coincide with the system number of this machine, polling is not allowed.
Default: 0 (Inhibited)
SW8 No.5 Remote reception indication
Used to set whether remote select function is used or not.
When set to 1, the function is allowed.
When set to 0, inhibited.
Default: 1 (Allowed)
SW8 No.6 – No.8 Inhibited to use
SW9 No.1 Print of total communication time and total pages
Used to set whether total communication time and total number of sheets are recorded or not on the communication record table.
When set to 1, the total communication time and the total number of pages are printed on the communication record table.
When set to 0, they are not printed on the communication record table.
Default: 1 (YES)
SW9 No.2 Inhibited to use
SW9 No.3 Quick memory transmission
Used to set whether quick memory transmission (transmission of ringing before completion of scanning) is performed or not. Linked with the key operator program menu.
Default: 1 (Allow)
SW9 No.4 Yes/No of SUB capacity in reception
Used to set notification of YES/NO of DIS signal Bit 49 SUB capacity.
"0": YES
"1": NO
Default: 0 (YES)
When notified 0 and NO, the F code transmission from the other party can be inhibited.
SW9 No.5 F-code relay broadcast function
Used to set whether F code relay broadcast instruction from the other party is received and relay broadcast transmission is performed or F code relay broadcast instruction is not received (though the relay box number by SUB coincides with) from the other party. Though this function is set to disable, F code instruction can be transmitted.
Default: 0 (Allow)
SW9 No.6 F-code confidential reception function
Used to set whether F code confidential reception from the other party is made or not (though the confidential box number by SUM coincides with).
Though this function is set to disable, F code transmission can be made.
Default: 0 (Allow)
SW9 No.7 Yes/No of SEP capacity in reception
Used to set notification of YES/NO of DIS signal Bit 47 SEP capacity.
"0": YES
"1": NO
Default: 0 (YES)
When set to 1 (NO), F code polling is inhibited.
SW9 No.8 Yes/No of reception PWD capacity
Used to set whether password function is judged or not for F code bulletin board polling.
"0": Password is judged. If password is not acceptable, communication is cut off.
"1": Password is not judged. Password is disregarded and communication is allowed.
Default: 0 (Password is judged.)
SW10 No.1 Measurement of communication time (image)
Used to set YES/NO of measurement.
Used to measure the communication time in phase C. However, it is the communication time in the latest phase C. (Unit: msec)
Default: 1 (YES)
SW10 No.2 Sender’s telephone number registration
Used to set Enable/Disable of registered transmitter telephone number change.
When set to 1, sender’s TEL No. cannot be registered and changed.
To prevent sender’s TEL No. from being changed erroneously, this is set to 1.
Default: 0 (Allow)
SW10 No.3 Yes/No of reception SID capacity
Used to set whether password is judged or nor in F code reception.
"0": Password is judged. If password is not acceptable, communication is cut off.
"1": Password is not judged. Password is disregarded and communication is allowed.
Default: 0 (Password is judged.)
SW10 No.4 SDT signal detection
Used to set whether SDT signal which is the second dial tone when transmitting to F net is detected or not.
When SDT signal is not detected, dialing is performed normally even after "16X."
When set to 1, the signal is detected.
When set to 0, the signal is not detected.
Default: 0 (Not detected)
SW10 No.5, No.6 Inhibited to use
SW10 No.7 ECM MMR mode
Used to set whether MMR coding system is used or not.
"1": MMR is used.
"0": MMR is not used.
Default: 1 (MMR communication is made.)
SW10 No.8 ECM JBIG mode
Used to set whether JBIG communication is used or not.
"1": JBIG communication is used.
"0": JBIG communication is not used.
Default: 1 (JBIG communication is used.)
SW11 No.1 – No.8 Inhibited to use
AR-FX4 SOFT SWITCH DESCRIPTIONS - 21
SW12 No.1 – No.5 Inhibited to use
SW12 No.6, No.7 CI detection
Used to set the frequency to detect CI signal which is the calling signal as follows: bit 6 7
0 0 : 4 sine wave (280ms)
1 0 : 3 sine wave (190ms)
0 1 : 2 sine wave (130ms)
1 1 : Similar to 4 sine wave (280mm).
Default: 0 0 (4 sine wave)
SW12 No.8 Inhibited to use
SW13 No.1 – No.6 Inhibited to use
SW13 No.7 Relay data output
Used to set whether the received document is outputted from the relay direction station when relay broadcasting direction is received.
When set to 1, the document received from the relay instruction station is printed.
When set to 0, the document received from the relay instruction station is not printed.
Default: 1 (Printed)
SW13 No.8 Relay broadcast function
Used to set whether relay broadcasting transmission is performed when receiving the relay broadcasting direction from the other party or the relay broadcasting direction is not received from the other party.
When set to 1, the relay broadcast instruction from the allowed party is received.
When set to 0, the relay broadcast instruction is not received even from the allowed party.
Default: 1 (The relay broadcast instruction is received.)
When this function is set to disable, relay broadcast instruction can be transmitted.
SW14 No.1 – No.4 V.34 mode sending speed
Used to set the transmission speed when starting communication in
V.34 mode.
Setting can be made by binary input of N in "2400 (bps) x N" in the range of 2400bps – 33600bps.
N can be set in the range of 0 – 15. When it is set to 0, 2400bps; when set to 15, 33600bps.
Default: N = 14 (Transmission is started from 33600bps.)
SW14 No.5 – No.8 V.34 mode reception speed
Used to set the reception speed when starting reception in V.34 mode.
Setting can be made by binary input of N in "2400 (bps) x N" in the range of 2400bps – 33600bps.
N can be set in the range of 0 – 15. When it is set to 0, 2400bps; when set to 15, 33600bps.
Default: N = 14 (Reception is started from 33600bps.)
SW15 No.1 Lower limit of speaker sound detection time
Lower limit of speaker sound detection time
1: 350ms 0: 250ms
Default: 0 (250ms)
SW15 No.2 Upper limit of speaker sound detection time
Upper limit of speaker sound detection time
1: 650ms 0: 750ms
Default: 0 (750ms)
SW15 No.3 Lower limit 2 of speaker sound detection time
Lower limit 2 of speaker sound detection time
1: 150ms 0: Follows SW15-1.
Default: 0 (Follows SW15-1.)
SW15 No.4 Inhibited to use
SW15 No.5 – No.8 Modem speed (V.33 mode or less)
Used to set the speed to start communication. When communication troubles occur frequently, the speed may be reduced to solve the troubles.
Default: 1 0 0 0 (V.17 14.4kbps)
SW16 No.1 Inhibited to use
SW16 No.2 External telephone connection
When this switch is not set to YES, an external telephone cannot be used.
Default: 1 (YES)
SW16 No.3, No.4 Inhibited to use
SW16 No.5 Rotation transmission selection (11 x 8.5
→
8.5 x 11)
Used to set whether letter R document is transmitted as A3 width or the scanned image is rotated and transmitted as A4R width.
Default: 1 (YES)
SW16 No.6 Rotation transmission selection (A4
→
A4R)
Used to set whether A4 document is transmitted as A4 or the scanned image is rotated and transmitted as A4R.
When set to 1, the document is transmitted as A4 width.
When set to 0, the document is transmitted as A3 width.
Default: 1 (Transmitted as A4 width.)
SW16 No.7 Rotation transmission selection (B5R
→
B5)
Used to set whether B5R document is transmitted as B5R or the scanned image is rotated and transmitted as B5.
When set to 1, the document is transmitted as B4 width.
When set to 0, the document is transmitted as A4 width.
Default: 1 (Transmitted as B4 width.)
SW16 No.8 Rotation transmission selection (A5
→
A5R)
Used to set whether A5R document is transmitted as A5R or the scanned image is rotated and transmitted as A5.
When set to 1, the document is transmitted as A4 width.
When set to 0, the document is transmitted as A5R.
(However, the transmission width is A4.)
Default: 1 (Transmitted as A4 width.)
SW17 No.1 Paper selection priority sequence
Used to set whether the FAX reception paper is selected by data width priority or data area priority.
"0": Area priority
"1": Width priority
Default: 0 (Area priority)
SW17 No.2, No.3 Output condition setup
Used to set whether the received data are reduced or divided to print when a document is received and there is no suitable size paper.
bit 2 3
0 0 : Reduction allowed
1 0 : Division allowed
Default: 0 0 (Reduction print)
SW17 No.4 – No.8 Inhibited to use
SW18 No.1, No.2 Inhibited to use
AR-FX4 SOFT SWITCH DESCRIPTIONS - 22
SW18 No.3, No.4 Reception size specification (Indicates reception capacity.)
Used to set the receivable document width which is informed the other party when receiving a communication.
The setup items are as follows: bit 3 4
0 0 : By the attached cassette
0 1 : B4 (A4/B4) width
1 0 : A4 width
1 1 : A3 (A4/B4/A3) width
Default: 0 0 (Varies depending on the installed cassette.)
Max. allowed reception width selection
Max. allowed reception width is determined by Table 1 and Table 2.
This determines the transmitted size from the other party.
When set to A3 with SW18-No. 3/No. 4 only with B5 cassette, proxy reception is always performed. Do not use this combination.
(Because division process in the main scanning direction is not performed.)
When set to A4 with SW18-No. 3/No. 4, A3 document from the other party is not divided into A4 paper but reduction to A4width is requested to the other party.
• Max. allowed reception width setup
SW18
No.3
No.4
0 0
0
1
1
1
0
1
A4
A3
Size specification
Depends on the installed cassette.
B4
Reception allowable width
Varies according to the table below.
A4 & B4 width
A4 width
A4 & B4 & A3 width
• Max. allowable reception width by installed cassette
[Max. paper size of installed
→ cassette with FAX function]
A5
B5
A4
B4
A3
→
No cassette with FAX function
→
→
→
→
→
[Sampled paper size
(Data width)]
A4
B4
A3
B4
A3
A3
SW18 No.5 11 inch reception capacity setup
When SW18-3 – 4 is set to "Depends on installed cassette," the max.
allowable reception width by 8.5 x 11" cassette is set.
When set to 0, the reception allowable width is A3.
When set to 1, the reception allowable width is B4.
Default: 0 (Reception allowable width is A3)
SW18 No.6 Output method when A3 width reception (Inch series)
Used to set whether an image of 297mm width is reduced and printed or an image of 11" width is printed without reduction on paper of 11" width when an image of A3 width is received.
When set to 0, printing is made on paper of 11" width.
When set to 1, printing is made on paper of 297mm width.
Default: 0 (Printed on paper of 11" width.)
SW18 No.7 Output method when A4 width reception (Inch series)
Used to set whether printing is made on paper of 8.5" width or of
210mm width when an image of A4 width is received.
When set to 0, printing is made on paper of 210mm width.
When set to 1, printing is made on paper of 8.5" width.
Default: 1 (Printing is made on paper of 8.5" width.)
SW18 No.8 Override print setup
Used to set whether the latter print job is performed or not when the former print job is suspended at the first page due to printable paper empty.
When set to 0, override print is not allowed.
When set to 1, override print is allowed.
Default: 1 (Override print allowed)
SW19 No.1 Protocol monitor
Used to set whether communication protocol result is printed after completion of communication or not.
Used for communication test.
Default: 0 (NO)
SW19 No.2 Inhibited to use
SW19 No.3 Output only in protocol monitor error
Used to set whether protocol monitor is outputted only when a communication error occurs or every time when communication is completed.
Effective when SW19 No. 1 (Protocol monitor) is set to YES. However, only when SW19 No. 1 is set to 1 (YES), protocol monitor is outputted in case of a communication error.
Default: 0 (NO)
SW19 No.4 Protocol monitor save
Used to set whether the protocol monitor of the final communication is saved or not.
When set to "Saved," the preceding protocol monitor can be printed with SIM 66-21.
Default: The protocol monitor is saved.
SW19 No.5 Inhibited to use
SW19 No.6 Recording table automatic print
Used to set whether the communication record table is printed automatically when each of transmission/reception data of communication record table reaches 50 items.
When set to 1, the table is automatically printed.
When set to 0, the table is not printed though the data reaches 50 items.
Default: 1 (Printed)
SW19 No.7 Time specification 1 of communication record table
Used to set whether time No. 1 is enabled or not in the output function of communication result table at the specified time.
Linked with the key operator program.
Default: 0 (Inhibit)
SW19 No.8 Time specification 2 of communication record table
Used to set whether time No. 2 is enabled or not in the output function of communication result table at the specified time.
Linked with the key operator program.
Default: 0 (Inhibit)
SW20 No.1, No.2 Line sound monitor range
Used to set the line sound monitor range when the line monitor function is used.
Used to set to monitor NSF signal send/receive until NSF signal is sent/received.
When set to ALL, all procedures up to line disconnection are monitored.
The setup items are as follows: bit 1 2
0 0 : Not used. (Same as 0.1)
0 1 : Up to NSF signal send/receive
1 0 : All
1 1 : Not used. (Same as 0.1)
Default: 0 1 (Up to NSF signal send/receive)
AR-FX4 SOFT SWITCH DESCRIPTIONS - 23
SW20 No.3 Line monitor display
Used to set whether the communication speed and the reception level are displayed on the LCD or not.
Displayed on the communication status screen by pressing the job status key.
When set to 1, displayed on LCD.
When set to 0, not displayed on LCD.
Default: 0 (Not displayed)
SW20 No.4 Data output specification in communication error during reception
Used to set whether the image on the page where a communication error occurred during image reception is printed or not.
"0": Setup to print
"1": Setup not to print
Default: 0 (Output)
However, “Output setting” is effective only when SW24-6 is set to "Output for every page reception."
SW20 No.5 Receivable memory capacity
Used to set the remaining memory capacity for acceptance of call.
When set to 1, ringing is made until the remaining memory capacity is
64KB or less.
When set to 0, ringing is made until the remaining memory capacity is
128KB or less.
Default: 0 (Ringing is made until the remaining is 128KB or less.)
SW20 No.6 Memory over during reception
Used to set whether the received data are output or destroyed when memory is over during reception.
When set to 1, received data are output.
When set to 0, received data are disposed without output.
Default: 1 (Received data are output)
SW20 No.7, No.8 Flag-adrs timer setup (V.21-FSK)
Used to set the time between Flag-adrs during FSk signal reception in a communication other than V.34 mode.
FSK signal reception in V.34 does not conform to this soft switch.
Default: 0 0 (6sec)
SW21 No.1 – No.8 Inhibited to use
Used to set the time interval between the end of a communication and a call for the next communication.
The actual interval is the setup value + 3.5sec.
Setup is made by binary input in the interval of 0 – 255sec.
The initial setup is to ring in the interval of 1sec.
SW22 No.1 – No.8 Inhibited to use
SW23 No.1 – No.8 Inhibited to use
SW24 No.1, No.2 Image capacity at send request
Used to set the image capacity of the machine when send request
(polling).
Reflected on DTC.
Default: 0 0 (Ultra fine)
SW24 No.3 Specified number reception
Used to set ON/OFF of the function to reject FAX reception from a registered number.
Default: 0 (Ignore specified number reception)
SW24 No.4 Specified number reception when manual reception
Used to set whether reception from manual reception is rejected or not when reception function by specifying the number is ON.
Default: 0 (Ignore specified number reception)
SW24 No.5 Inhibited to use
SW24 No.6 Document output setup in reception
Used to set whether all received documents are outputted at a time after completion of reception or each document is outputted every time when it is received.
When set to 1, all are outputted collectively after completion of reception.
When set to 0, output is made after reception of every page.
Default: 0 (Output after reception of every page)
SW24 No.7 Inhibited to use
SW24 No.8 Automatic reduction print
Used to set whether the received document is automatically reduced and printed so that the print-out is fit in a fixed size when the document size is longer than the fixed sizes but smaller than the max. length of automatic reduction ratio.
When set to 1, the document is automatically reduced and printed.
When set to 0, the document is printed without reduction.
Default: 1 (Automatic reduction print enable)
SW25 No.1 – No.4 Automatic reduction rate setup
Used to set the auto reduction ratio when "Auto reduction print" is set to Enable.
Setup is made in the range of 0 – 15% by binary input of N in "100% –
N x 1%."
Default: 94% (Reduce 6%)
SW25 No.5 – No.8 Inhibited to use
SW26 No.1 – No.8 Inhibited to use
SW27 No.1 Inhibited to use
SW27 No.2 – No.5 Recording paper tray selection
(Tray 1 – 4)
Used to select the tray for output of the received documents.
Tray 1 to Tray 4 can be set to ON/OFF individually. When set to OFF, the tray does not output received documents.
Setup is made by selecting bit 2 – bit 5. Each bit is selected in the sequence of tray 1 – tray 4.
When bit 1 is selected, output is made by using that tray.
When bit 0 is selected, output is made by using that tray.
Default: Tray 1 – tray 4 are used.
bit bit bit bit
4
5
2
3
: Tray 1
: Tray 2
: Tray 3
: Tray 4
SW27 No.6 – No.8 Inhibited to use
SW28 No.1 – No.8 Inhibited to use
SW29 No.1 – No.4 Inhibited to use
SW29 No.5 – No.8 Setup of number of times of call rings
Used to set the number of call rings until reception is started in auto reception mode.
The set range is 0 to 9 times by binary input.
When set to 0, no ring is made.
Default: 2 times
SW30 No.1 Report output when canceling
Used to set whether the communication report table is outputted or not when canceling transmission during document transmission.
When set to 1, the communication report table is printed.
When set to 0, the communication report table is not printed.
Default: 0 (Not printed)
SW30 No.2 Inhibited to use
AR-FX4 SOFT SWITCH DESCRIPTIONS - 24
SW30 No.3 Rotation print
Used to set Enable/Disable of rotation print when the received document can be printed by rotation.
When set to 1, the received document is rotated and printed.
When set to 0, the received document is not rotated.
Default: 1 (The received document is rotated and printed.)
SW30 No.4 Department management
Used to set Enable/Disable of FAX using dept. management by the use of the dept. management function.
When set to 1, the department management function is used.
When set to 0, the department management function is not used.
Default: 0 (The department management function is not used.)
SW30 No.5 Default data, sender print
Used to set whether the registered sender information and date and time of transmission are printed at the top of the transmission document when a document is transmitted through the second line.
When set to 1, date and sender are printed.
When set to 0, date and sender are not printed.
Default: 1 (Date and sender are printed.)
SW30 No.6 Department name notification
Used to set whether the department name is transmitted as sender information when the department management function is enabled.
Default: 0 (OFF)
SW30 No.7 Date/sender print position setup
Used to set the print position of date and transmitter information on the transmitted documents.
When set to 1, printed at the top of the document.
When set to 0, added outside the document.
Default: 0 (Added outside the document.)
SW30 No.8 Report output (in confidential reception)
Used to set whether the communication report table is outputted or not when a confidential reception is made.
When set to 1, the communication report table is printed.
When set to 0, the communication report table is not printed.
Default: 1 (Printed)
SW31 No.1, No.2 Report output (in transmission)
Used to set whether the communication report is outputted or not after completion of transmission (excluding sequential broadcasting, sequential send request, and relay broadcasting).
Setup is selected from "print inhibition," "all output," and "only when transmission is failed" as follows: bit 1 2
0 0 : Print inhibited
0 1 : All are printed.
1 0 : Only when transmission is failed.
1 1 : Not used (Same as "Only when transmission is failed.")
Default: 1 0 (Outputted only when transmission is failed.)
SW31 No.3, No.4 Report output (In broadcast, sequential send request, and relay broadcast)
Used to set whether the communication report table is outputted or not after completion of transmission (sequential broadcasting, sequential send request, and relay broadcasting).
Setup is selected from "print inhibition," "all output," and "only the address to which transmission is failed" as follows: bit 3 4
0 0 : Print inhibited
0 1 : All are printed.
1 0 : Only the address to which transmission is failed.
1 1 : Not used (Same as "Only the address to which transmission is failed")
Default: 0 1 (All are printed.)
SW31 No. 5, No.6 Report output (in reception)
Used to set whether the communication report table is outputted or not when a reception (excluding confidential reception) is made.
Setup is selected from "print inhibition," "all output," and "only in error" as follows: bit 5 6
0 0 : Print inhibited
0 1 : All are printed.
1 0 : Only in error
1 1 : Same as "print inhibited."
Default: 0 0 (Print inhibited)
SW31 No.7, No.8 Inhibited to use
SW32 No.1 – No.4 Distinctive ring
The function judges TEL or FAX by CI ringing.
Default: 0 0 0 0 (OFF)
SW32 No.5 Inhibited to use
SW32 No.6 Index print setup
Used to set whether the index is printed or not when outputting received documents.
When set to 1, the index is printed on the received document.
When set to 0, the index is not printed.
Default: 0 (The index is not printed.)
SW32 No.7, No.8 Inhibited to use
SW33 No.1 Page number print setup
Used to set whether the page number is added to the position where date and transmitter information are printed. (In memory transmission, paper number/total number of pages)
When set to 1, the page number is printed.
When set to 0, the page number is not printed.
Default: 1 (The page number is printed.)
SW33 No.2 – No.8 Inhibited to use
SW34 No.1 – No.8 Inhibited to use
SW35 No.1 Cover function default setup
Used to set whether the cover is added or not when transmitting.
When set to 1, the cover is added.
When set to 0, the cover is not added.
Default: 0 (The cover is not added.)
SW35 No.2 Inhibited to use
SW35 No.3, No.4 CI delete max. OFF time
Used to set the max. wait time from detection of CI signal pulse (number of times) to the next CI signal pulse detection. If next Ci signal pulse is not detected within this time, the number of calls up to now is cleared.
The setup items are as follows: bit 3 4
0 0 : 5sec
0 1 : 10sec
1 0 : 15sec
1 1 : 20sec
Default: 0 1 (10sec)
SW35 No.5 – No.8 Inhibited to use
SW36 No.1 – No.8 Inhibited to use
SW37 No.1 – No.8 Inhibited to use
SW38 No.1 – No.4 Pause time setup
Used to set the pause time.
The set range is 1 sec to 15 sec by binary input.
When set to 0, it is the same as 2 sec.
Default: 2sec
AR-FX4 SOFT SWITCH DESCRIPTIONS - 25
SW38 No.5, No.6 Inhibited to use
SW38 No.7 Transfer function
Used to set Enable/Disable the transfer function.
Default: 0 (Inhibit)
SW38 No.8 Inhibited to use
SW39 No.1 – No.3 Call time setup in automatic transmission (T0 timer setup)
Used to set the call time when call does not reach the other party in auto send mode.
The set range is 30 to 60 sec in the increment of 5 sec by binary input of "(5 sec x N) + 30 sec)".
"N" can be set in the range of 0 to 7. When set to 7 (65 sec), it is the same as setup of 45 sec.
Default: 45sec (N=3)
SW39 No.4 – No.8 Inhibited to use
SW40 No.1 – No.4 Number of times of recall in error
Used to set the number of recall times in case of a communication error.
Setup is made in the range of 0 – 1 times by binary input.
When set to 0, recall is not made.
Default: 1 time of recall
SW40 No.5 – No.8 Number of times of recall in busy
Used to set the number of recall times in case of busy state of the other party or when call does not reach the other party.
Setup is made in the range of 0 – 14 times by binary input.
When set to 0, recall is not made.
Default: 2 times of recall
SW41 No.1, No.2 Tone/Pulse default setup
Employed line setup (Dial setup)
Selection of 10PPS, 20PPS, and TONE is allowed.
The setup items are as follows: bit 1 2
0 0 : 10PPS
0 1 : 20PPS
1 0 : TONE
1 1 : Similar to TONE.
Default: 1 0 (TONE)
SW41 No.3 Telephone line menu
Used to set whether Tone/Pulse setup is displayed on the menu or not.
Default: 0 (Fixed to “Allow”)
SW41 No.4 Maintenance system
Setup of the model for judgment of consumable parts system when using the F.A.S.T. function.
SW41 No.5 F.A.S.T mode
Used to set Enable/Disable of FAST operation.
To enable FAST operation, the serviceman must change this SW setup.
Default: 0 (NO)
SW41 No.6, No.7 Sequence of year/month/day in LCD, report, and sender record
Used to set the sequence of year, month, and day in the display, report, and sender record.
SW41 No.8 Time display format
Used to set the sequence of year, month, and day in the LCD display, report, and sender record.
When set to 0, time is indicated in 24H format.
When set to 1, time is indicated in AM/PM format.
Default: 1 (AM/PM)
SW42 No.1 Direct send recall Allow/Inhibit
Used to set allow/inhibit of wait for recall in direct send.
Default: 1 (Allow)
SW42 No.2, No.3 Inhibited to use
SW42 No.4 Manual/Auto reception auto swiching
Used to set whether automatic reception is made or not when ringing is made the number of auto switch call times in manual reception.
Default: 0 (Inhibit)
SW42 No.5 – No.8 Number of auto switch calls of manual reception
→
auto reception
When the above setup is allowed, automatic reception is made at the set number of times.
The set range is 1 to 9 times.
Default: 9 times
SW43 No.1 – No.5 DTMF signal send time
Used to set the send time when sending DTMF signal.
Setup is made in the range of 60 – 310ms by binary input of N in
"10(ms) x N" in the increment of 10ms.
N is set in the range of 0 – 31.
When N is set to 0, it is the same as 110ms (N=11).
Default: 110ms
SW43 No.6 – No.8 Maintenance cycle
Setup for judgment of consumable parts notification when using the
F.A.S.T. function. This setup should be the same as SIM21-2 setup.
Default: 0 0 1 (50K)
SW44 No.1 – No.4 Scan effective image area (OC) Main scan Left edge image loss
Used to set the left edge image loss of main scan in OC scan of FAX.
The set value of SIM 50-8 is reflected.
SW44 No.5 – No.8 Scan effective image area (SPF) Main scan Left edge image loss
Used to set the left edge image loss of main scan in SPF scan of FAX.
The set value of SIM 50-8 is reflected.
SW45 No.1 – No.4 Scan effective image area (OC) Main scan Right edge image loss
Used to set the right edge image loss of main scan in OC scan of FAX.
The set value of SIM 50-8 is reflected.
SW45 No.5 – No.8 Scan effective image area (SPF) Main scan Right edge image loss
Used to set the right edge image loss of main scan in SPF scan of
FAX.
The set value of SIM 50-8 is reflected.
SW46 No.1, No.2 Inhibited to use
SW46 No.3 Priority in the day of week
Used to set the recording sequence of the day of month and the day of week if the date is in the sequence of day, month, and year.
Default: 0 (NO)
SW46 No.4 Inhibited to use
SW46 No.5 Daylight saving tive
Used to set Enable/Disable of Daylight saving time.
Default: 0 (Inhibit)
SW46 No.6 – No.8 Inhibited to use
SW47 No.1 – No.5 Time specification print 1 (O’clock) in the communication report table
Used to set "o’clock" of the time (o’clock, min) when specifying the time in the communication report table.
Setup is in the range of 0 – 23 (o’clock) by binary input.
When set to 24 – 31, the time is set to 0 o’clock.
Default: 0 o’clock
AR-FX4 SOFT SWITCH DESCRIPTIONS - 26
SW47 No.6 – No.8 Inhibited to use
SW48 No.1 – No.6 Time specification print 1 (min) in the communication report table
Used to set "min" of the time (o’clock, min) when specifying the time in the communication report table.
Setup is in the range of 0 – 59 (min) by binary input.
When set to 60 – 63, the time is set to 0 min.
Default: 0 min
SW48 No.7, No.8 Inhibited to use
SW49 No.1 – No.5 Time specification print 2 (O’clock) in the communication report table
Used to set "o’clock" of the time (o’clock, min) when specifying the time in the communication report table.
Setup is in the range of 0 – 23 (o’clock) by binary input.
When set to 24 – 31, the time is set to 0 o’clock.
Default: 0 o’clock
SW49 No.6 – No.8 Inhibited to use
SW50 No.1 – No.6 Time specification print 2 (min) in the communication report table
Used to set "min" of the time (o’clock, min) when specifying the time in the communication report table.
Setup is in the range of 0 – 59 (min) by binary input.
When set to 60 – 63, the time is set to 0 min.
Default: 0 min
SW50 No.7, No.8 Inhibited to use
SW51 No.1 – No.5 Inhibited to use
SW51 No.6 CED detection time
Used to set CED/ANSam signal detection time. When the CED/
ANSam signal is detected for duration of the set time, it is recognized.
When set to 1, if a signal is detected for 500ms or more, it is recognized.
When set to 0, if a signal is detected for 1000ms or more, it is recognized.
Default: 0 (1000ms or more)
SW51 No.7, No.8 Busy tone detection cycle
Used to set the number of pulses of busy tone detected to recognize as busy tone.
When set to 0 0, 2 pulses are detected.
When set to 0 1, 4 pulses are detected.
When set to 1 0, 6 pulses are detected.
When set to 1 1, 10 pulses are detected.
Default: 0 0 (2 pulses are detected for recognition of busy tone.)
SW52 No.1, No.2 Busy tone detection level
Used to set the lowest detection level when detecting busy tone.
When set to 0 0, busy tone of –43dB is detected.
When set to 0 1, busy tone of –35dB is detected.
When set to 1 0, busy tone of –33dB is detected.
When set to 1 1, busy tone of –30dB is detected.
Used to set for erroneous detection of busy tone.
Default is 0 0 (–43dB).
SW52 No.3 ERR frame reception operation
Used to set the operation when image data with error frame is received.
"0": Not continue process. (Error)
"1": Continues process.
Default: 0 (Not continue process. (Error))
SW52 No.4 Inhibited to use
SW52 No.5 Error process in RTN reception
Used to set whether RTN reception is treated as a communication error or not.
When set to 1, it is not judged as an error when RTN is received.
When set to 0, it is judged as an error when RTN is received.
Default: 0 (Judged as an error.)
SW52 No.6 V.34 mode function in manual communication
Used to set whether V.34 mode function is enabled or not in manual transmission.
When set to 1, V.34 mode function is enabled.
When set to 0, V.34 mode function is disabled.
Default: 1 (V.34 mode function is enabled.)
SW52 No.7 V.34 mode function
Used to set whether V.34 mode is used for send/receive with the other party machine is provided with V.34 mode.
When set to 1, send/receive is made by using V.34 mode.
When set to 0, send/receive is made without using V.34 mode.
Default: 1 (V.34 mode function is enabled.)
SW52 No.8 V.34 control channel communication speed
Used to set V.34 mode communication speed of the control channel.
When set to 1, the communication speed of control channel is
2400bps.
When set to 0, the communication speed of control channel is
1200bps.
Default: 0 (1200bps)
SW53 No.1 – No.4 DTMF send level (High group) setup
Used to set the DTMF signal send level (high group).
The set range is 0 to 7.5 with binary input in the increment of 0.5dB.
Default: 3.5
Send level = – (set value + 12)/2 [dB]
SW53 No.5 – No.8 DTMF send level (Low group) setup
Used to set the DTMF signal send level (low group).
The set range is 0 to 7.5 with binary input in the increment of 0.5dB.
Default: 3.5
Send level = – (set value + 12)/2 [dB]
SW54 No.1 – No.4 Scan effective image area (OC) Sub scan lead edge image loss
Setup of image loss in OC scan image area
The quantity of image loss at the lead edge in sub scan direction can be adjusted. When the set value is increased, the lead edge image loss quantity is increased.
The set value of SIM 50-8 is reflected.
SW54 No.5 – No.8 Scan effective image area (SPF) Sub scan lead edge image loss
Used to set image loss in SPF scan image area.
The quantity of image loss at the lead edge in sub scan direction can be adjusted. When the set value is increased, the lead edge image loss quantity is increased.
The set value of SIM 50-8 is reflected.
SW55 No.1 – No.7 CI signal OFF detection enable time
Used to set the min. OFF time for judgment of CI pulse (16Hz call signal). When OFF time continues for more than the set time, it is judged as 1 pulse of CI.
Setup is made in the range of 0 – 1270 by binary input. Set value x
10ms.
Default is 1200ms.
AR-FX4 SOFT SWITCH DESCRIPTIONS - 27
SW55 No.8 EQM judgment threshold value
Used to set whether the threshold value, FTT, for EQM judgment is severely adjusted or loosely adjusted when confirming TCF reception.
When it is loosely adjusted, TCF is easy to return CFR, however, it is apt to cause an error in PIX (Phase-C).
SW56 No.1 – No.8 Inhibited to use
SW57 No.1 – No.8 Inhibited to use
SW58 No.1 V.34 3429 (baud) Rate Mask
Used to set whether 3429 is supported as the symbol rate in V.34 communication or not.
SW58 No.2 V.34 3200 (baud) Rate Mask
Used to set whether 3200 is supported as the symbol rate in V.34 communication or not.
SW58 No.3 V.34 3000 (baud) Rate Mask
Used to set whether 3000 is supported as the symbol rate in V.34 communication or not.
SW58 No.4 V.34 2800 (baud) Rate Mask
Used to set whether 2800 is supported as the symbol rate in V.34 communication or not.
SW58 No.5 Inhibited to use
SW58 No.6 V.34 2400 (baud) Rate Mask
Used to set whether 2400 is supported as the symbol rate in V.34 communication or not.
SW58 No.7, No.8 Inhibited to use
SW59 No.1 – No.8 Inhibited to use
SW60 No.1 – No.4 Inhibited to use
SW60 No.5 Countermeasures against V.34 communication error (reception) (Phase 2 error retry setup)
Improves and controls error retry in phase 2 of V.34 reception.
Default: 0 (NO)
SW60 No.6 Countermeasures against V.34 communication error (transmission) (Phase 2 error retry setup)
Improves and controls error retry in phase 2 of V.34 transmission.
Default: 0 (NO)
SW60 No.7, No.8 Inhibited to use
SW61 No.1 – No.8 Inhibited to use
SW62 No.1 – No.8 Inhibited to use
SW63 No.1 – No.8 Inhibited to use
SW64 No.1 – No.8 Inhibited to use
SW65 No.1 – No.8 Inhibited to use
SW66 No.1 – No.8 Inhibited to use
SW67 No.1 – No.4 Setup of make rate (10PPS)
Used to set the make rate when dialing at 10PPS.
The set range of N is 0 to 15 in binary input for the make rate of (N +26 ms), which ranges from 26 to 41 ms.
Default: 40 ms
SW67 No.5 – No.8 Inhibited to use
SW68 No.1 – No.4 Inhibited to use
SW68 No.5 – No.8 T1 timer setup
Used to set time-out time from phase B to detection of signal.
T1 time-out time is set in the range of 30 – 105sec (in the increment of
5sec).
Default is 40sec.
SW69 No.1 – No.8 Inhibited to use
SW70 No.1 – No.8 Inhibited to use
SW71 No.1, No.2 Dial ringing wait time
Used to set wait time from connection of the line to start of dial ringing.
When ringing is made without detecting dial tone, ringing is made after setting this time.
When set to 0 0, ringing is made after 3.5sec.
When set to 0 1, ringing is made after 4sec.
When set to 1 0, ringing is made after 5sec.
When set to 1 1, ringing is made after 6sec.
Default: 0 0 (Ringing after 3.5sec)
SW71 No.3 – No.6 Inhibited to use
SW71 No.7, No.8 Silent detection level
Used to set the judgment level of silence.
When set to 0 0, –43dBm or less is judged as silence.
When set to 0 1, –40dBm or less is judged as silence.
When set to 1 0, –39dBm or less is judged as silence.
Default: 0 0 (–43dBm or less is judged as silence.)
SW72 No.1 EYE-Q check
Used to set whether TCF is checked or not in TCF reception.
When set to 1, check is made only with EQM value. Therefore, TCF check becomes loose.
When set to 0, check is made both with received data and EQM value.
Default: 0 (check is made both with received data and EQM value. )
SW72 No.2 – No.8 Inhibited to use
SW73 No.1 – No.6 Inhibited to use
SW73 No.7, No.8 DIS reception process selection in reception
Used to set the process when DIS is received.
When set to 0 0, it is judged as reception of echo and the command is sent again.
When set to 0 1, the line is disconnected as improper DIS.
When set to 1 0, if DIS is the receiver machine and there are some accumulated documents, bulletin transmission is made. In other cases, it is judged as reception of echo and the command is sent again.
When set to 1 1, if DIS is the receiver machine and there are some accumulated documents, bulletin board is transmitted. If DIS is the transmitter machine, it is judged as reception of echo and the command is sent again. In the other cases, it is judged as improper DIS and the line is disconnected.
Default: 0 0 (Judged as reception of echo, and the command is sent again.)
SW74 No.1 – No.4 Print lead edge adjustment (Lead edge adjustment)
Setup of print image area void
The quantity of lead edge void in sub scan direction can be adjusted.
When the set value is increased, the lead edge void is increased.
Setup of SIM 50-9 is reflected.
SW74 No.5 – No.8 Print lead edge adjustment (Rear edge adjustment)
Setup of print image area void
The quantity of lead edge void in sub scan direction can be adjusted.
When the set value is increased, the lead edge void is increased.
Setup of SIM 50-9 is reflected.
AR-FX4 SOFT SWITCH DESCRIPTIONS - 28
SW75 No.1, No.2 Transmission end sound (Buzzer sound length) setup
Setup of the length of buzzer sound indicating the completion of transmission.
Setup is selected from 3sec, 1sec, and silent as follows: bit 1 2
0 0 : 3sec
0 1 : 1sec
1 0 : Silent
1 1 : Similar to the setup of 3sec.
Default: 0 0 (3sec)
SW75 No.3, No.4 Reception end sound (Buzzer sound length) setup
Setup of the length of buzzer sound indicating the completion of transmission.
Setup is selected from 3sec, 1sec, and silent as follows: bit 3 4
0 0 : 3sec
0 1 : 1sec
1 0 : Silent
1 1 : Similar to the setup of 3sec.
Default: 0 0 (3sec)
SW75 No.5 – No.8 Print lead edge adjustment (Left edge)
Setup of print image area void
The quantity of left edge void in main scan direction can be adjusted.
When the set value is increased, the image void becomes greater.
Setup of SIM 50-9 is reflected.
SW76 No.1 – No.8 Scan magnification ratio adjustment
OC (main scan)
The magnification ratio in main scan direction of OC scan is adjusted.
Setup of SIM 48-8 is reflected.
SW77 No.1 – No.8 Scan magnification ratio adjustment
OC (sub scan)
The magnification ratio in sub scan direction of OC scan is adjusted.
Setup of SIM 48-8 is reflected.
SW78 No.1 – No.8 Print magnification ration adjustment
(main scan)
The magnification ratio in main scan direction when printing is adjusted.
Setup of SIM 48-9 is reflected.
SW79 No.1 – No.8 Print magnification ration adjustment
(sub scan)
The magnification ratio in sub scan direction when printing is adjusted.
Setup of SIM 48-9 is reflected.
SW80 No.1 – No.4 Scan effective image area (OC) Sub scan Rear edge image loss
Setup of image loss in OC scan image area
The quantity of image loss at the rear edge in sub scan direction can be adjusted. When the set value is increased, the image loss quantity at the rear edge is increased.
The set value of SIM 50-8 is reflected.
SW80 No.5 – No.8 Scan effective image area (SPF) Sub scan Rear edge image loss
Used to set image loss in SPF scan image area.
The quantity of image loss at the rear edge in sub scan direction can be adjusted. When the set value is increased, the image loss quantity at the rear edge is increased.
The set value of SIM 50-8 is reflected.
SW81 No.1 – No.4 Destination information
Destination setup
AR-FX4 SOFT SWITCH DESCRIPTIONS - 29
SW81 No.5 – No.8 Language information
Language setup
SW82 No.1 – No.8 Scan magnification ratio adjustment
SPF (main scan)
SPF scan main scan magnification ratio setup
Setup of SIM 48-8 is reflected.
SW83 No.1 – No.8 Scan magnification ratio adjustment
SPF (sub scan)
SPF scan sub scan magnification ratio setup
Setup of SIM 48-8 is reflected.
SW84 No.1, No.2 On-hook speaker volume
The speaker volume is set when on-hook.
SW84 No.3 – No.8 On-hook pattern number
Pattern of sound volume (Large/Medium/Small) when on-hook.
Refer to SIM 66-37.
SW85 No.1, No.2 Line monitor speaker volume
Used to set the line sound volume from the speaker in FAX transmission.
SW85 No.3 – No.8 Line monitor pattern number
Pattern of line monitor sound volume (Large/Medium/Small)
SW86 No.1, No.2 Ringing volume
Used to set the ringing sound volume.
SW86 No.3 – No.8 Ringing pattern number
Pattern of ringing sound volume (Large/Medium/Small)
SW87 No.1, No.2 Speaker volume in DTFM send
Used to set the volume of transmission sound and DTMF sound from speaker when pressing on-hook button.
SW87 No.3 – No.8 Pattern number in DTFM send
Pattern of sound volume (Large/Medium/Small) when sending DTMF
SW88 No.1, No.2 Speaker volume at scanner scan end
Used to set the volume of scan end sound from the speaker when scan is completed.
SW88 No.3 – No.8 Pattern number in scanner scanning
Pattern of sound volume (Large/Medium/Small) when scan is completed.
SW89 No.1, No.2 Speaker volume of communication end sound
Used to set the volume of communication end sound from the speaker when communication is completed.
SW89 No.3 – No.8 Pattern number of communication end sound
Pattern of sound volume (Large/Medium/Small) of communication end
SW90 No.1 – No.8 Inhibited to use
SW91 No.1 – No.8 Inhibited to use
SW92 No.1 – No.8 Inhibited to use
SW93 No.1 – No.8 Inhibited to use
SW94 No.1 – No.8 Inhibited to use
SW95 No.1 – No.8 Inhibited to use
SW96 No.1 – No.8 Inhibited to use
SW97 No.1 – No.8 Inhibited to use
[7] KEY OPERATOR PROGRAM
1. List
Function setup
List output, setup
Initial setup
Send function setup
Program name
No
Soft SW setup
Program function (Outline)
List output
Communication result table print
SW30-8
SW31-1 – 8
Key operator list, confidential ID list, reception rejection number list, F code setup check list, department code table, and department management record table are printed.
This setup is made to print the communication result (normal completion or communication error) after completion of communication (normal transmission, broadcasting, reception, confidential reception).
This setup is made to print data (which were tried to be sent) under the result table in case of a communication error.
The content of document is printed in case of a communication error.
Recording table print
Dial ring signal setup
Pause time
Sender registration
Sound volume
Send image quality, density
Automatic reduction transmission
Rotation transmission
SW1-7
SW47-1 – 5
SW48-1 – 6
SW49-1 – 5
SW50-1 – 6
SW19-7, 8
SW41-1, 2
This setup is made to print all the previous communication data at the specified time.
SW38-1 – 4 Used to set the pause time between destination numbers.
SW10-2 Used to register the telephone number and the sender’s name to use this machine.
SW84-1, 2
SW85-1, 2
SW86-1, 2
SW16-2
Used to set the kind of telephone line connected to this machine.
Used to set when on-hook volume, ringing volume, and line monitor volume are adjusted.
Used to set connection of external telephone.
External telephone connection
Remote switch number
Department management
Department number
Date, time
Distinctive ring
Daylight saving tive
Page number print
Default transmission setup
Quick online
Date/sender print position
Department name notification
SW2-1 – 8
SW8-5
SW30-4
No Used to register department codes and department names in department management.
Used to set date and time of the clock built in the machine.
No
SW32-1 – 4 The function judges TEL or FAX by CI ringing.
SW46-5 Used to set Enable/Disable of Daylight saving time.
SW3-1 – 5
SW1-6
Used to set when remote switch number is changed in order to enter FAX reception mode from external telephone mode.
Used to set department management.
SW16-5, 6
SW33-1
SW8-1
Used to set image quality and density under the standard state of FAX mode.
Used to set to reduce document images according to the recording paper size of the other party.
Used to set whether document placed longitudinally is transmitted laterally or transmitted by rotating reversely. (Rotation transmission setup is available for letter size, not available for B5R/A5R.)
Used to set to print page number on the top of paper in the other party.
SW9-3
SW30-7
SW30-6
Used to set the transmission mode under the standard state to memory send or direct send.
Used to set memory send or quick online send when transmission mode is memory send.
Used to set print position of date and sender at the top of recording paper of the other party.
Used to set whether document placed longitudinally is transmitted laterally or transmitted by rotating reversely.
Recall when the other party is busy.
Recall in case of a transmission error
SW4-5 – 8
SW40-5 – 8
SW4-1 – 4
SW40-1 – 4
Used to set the recall interval and the number of times of recalls when the line is busy.
Used to set resend interval and the number of times of resending when a communication error occurs during transmission.
Call time in automatic send SW39-1 – 3 Used to set the time up to disconnection of line when the other party does not respond to calling made by automatic dialing of registered number in this machine.
Cover function default setup SW35-1 Used to set whether the cover is added or not when transmitting.
AR-FX4 KEY OPERATOR PROGRAM - 1
Function setup
Reception function setup
Special function setup
Program name
Number of times of automatic reception call
Reception data print tray
Reception data print condition
Automatic reduction print in a fixed size
Reception data transfer
Soft SW setup
Program function (Outline)
SW29-5 – 8 Used to set the number of times of calls until reception is started in automatic reception state.
SW27-2 – 5 Used to set recording paper tray for printing reception data]
SW17-2 – 3 Used to set whether reduction print is made or divided print is made when there is
SW24-8 no paper of the same size as the received image.
Used to set whether reduction print is made or not according to the size of paper set in the tray when data of greater size than the size of paper set in the tray.
SW38-7
No
Used to set data transfer to the telephone number registered in this program when image data received in the memory of this machine cannot be outputted.
The FAX number to be transferred is registered.
Registration of telephone number to transfer reception data
Index print
Reception data override
SW32-6
SW18-8
Output method when A3 width reception (Inch series)
Specified number reception
Polling protection
SW18-6
SW24-3
SW1-5
No
Used to set whether a black mark (index) is printed at the top of recording paper.
Used to set to print the latter data prior to the former data when printing of the former data is in standby state due to recording paper empty, etc. and the latter data are ready to print.
Used to set whether an image of 297mm width is reduced and printed or an image of 11" width is printed without reduction on paper of 11" width when an image of
A3 width is received.
Used to set ON/OFF of the function to reject FAX reception from a registered number.
Used to set the protection function when transmission is made by receiving polling.
Used to register or delete the other party’s number for transmission by polling.
Registration of polling allow number
ID number registration
System number registration
Relay ID code registration
Confidential box registration
No
No
SW13-8
No
Used to set the system number of the other party’s machine.
Used to set for registration of the system number of this machine.
Used to set for registration of the relay broadcast transmission allow number from the transmission station.
Used to set for registration of the confidential box number and password of confidential reception.
Used to set for registration of memory box for F code confidential reception.
F code confidential box registration
Registration of F code relay group
Registration of F code bulletin board
No
No
No
Used to set for registration of memory box for F code relay reception.
Used to set for registration of memory box for F code bulletin board transmission.
2. Operating procedure
The key operator program can be set from all the modes (copy, FAX, printer, scanner). When setup is completed, the mode returns to the original mode.
Note:
• When the key operator program is used, send/receive of FAX cannot be made.
• The key operator program cannot be used during send/receive of
FAX or during communication.
A. Common procedures
1) Press [SPECIAL FUNCTION] key.
SPECIAL FUNCTION
2) Select the key operator program with [UP] [DOWN] keys, and press [OK] key.
BACK
SPECIAL FUNCTION
CONFIGURATION
PAPER SIZE SET
DISPLAY CONTRAST
KEY OPERATOR PRG.
SPECIAL FUNCT
3) Enter the key operator code.
• Enter a code of 5 digits and go to step 4).
• When a code is entered, "-" is changed to "*."
• When an erroneous key is pressed, press [CLEAR] key and enter the correct entry again.
AR-FX4 KEY OPERATOR PROGRAM - 2
4) Select FAX with [UP] [DOWN] keys, and press [OK] key.
• Select COPY, and the key operator program in the copy mode can be set.
BACK
SPECIAL FUNCTI
5) Perform setup of each program according to the description in the following pages.
• Set and register the program for setup of the following functions.
List output/setup, initial setup, transmission function setup, reception function setup, special function setup
6) When setup is completed, press [CA] (Clear All) key.
• Terminate the key operator program.
Press [BACK] key to return to the previous screen.
To terminate each program, press [CA] (Clear All) key.
B. List output
1) Perform common operating procedures up to step 4).
2) Select "List output/Setup" with [UP] [DOWN] keys and press [OK] key.
3) Select "List output" with [UP] [DOWN] keys and press [OK] key.
4) Select a list name to output with [UP] [DOWN] keys and press [OK] key.
• Select among Key operator table, Confidential ID table, F code setup check table, Department code table, and Department management record table *.
• When the key operator program is terminated, print is started.
* This item is displayed on the list only when department management is set to ON (Effective) in the initial setup of the key operator program.
Key operator list
Confidential ID table
F code setup check table
Department code table
Department management record table
Anti Junk list
Used to print the current setup conditions of key operator program.
Used to print the contents of confidential box registration (confidential box number, confidential box name, ID number).
Used to print the contents of F code confidential box registration, F code relay group registration, and F code bulletin board registration.
Used to print registered numbers, department names, and department numbers.
Used to print communication time and communication pages in each department.
The reception rejection telephone number list is printed.
(3) Print method of record table
1) Press [SPECIAL FUNCTION] key in the FAX mode.
2) Select "PRINT" with [UP] [DOWN] keys, and press [OK] key.
3) Select "Record table" with [UP] [DOWN] keys, and press [OK] key.
4) Select a record table name to be printed with [UP] [DOWN] keys, and press [OK] key.
• Print reservation is made and print is made automatically.
• Printable record table
Communication record table, communication reservation table, document load check table, speed dial table, rapid dial table, group table, telephone number table, program table, relay group table, ID sender table, confidential reception check table
When [CA] key is pressed in the record table selection screen, the display returns to the initial screen. When [BACK] key is pressed, the display returns to the print selection screen of step 3).
The communication record table can be automatically printed by specifying time to print. Specification of print time can be set by the key operator program up to 2 times per day.
AR-FX4 KEY OPERATOR PROGRAM - 3
[8] FLASH ROM VERSION UP
PROCEDURE
(Items necessary for upgrade)
A
Personal computer
B
RS232C Cross cable (D-sub 9pin to D-sub 9pin, or D-sub 25pin to
D-sub 9pin)
C
Software for upgrade
(Type of ROM)
Flash ROM is directly attached to each PWB
(Targeted PWBs)
1
MCU-PWB
2
FAX-PWB
Diagrammatic sketch for upgrade method
(Personal computer)
A
B
RS232C Cross cable
(D-sub 9pin to D-sub 9pin) or
(D-sub 25pin to D-sub 9pin)
RS232C connector
(9pin or 25pin)
C
Download data
1
I/F Circuit (9pin)
MCU-PWB
1. Program download procedure (Main body program, FAX program)
Follow the procedure below to download the main body program and the FAX program:
1) Preliminary procedure: Connect PC and the main body with the download cable (RS-232C cable).
2) PC side: Boot the maintenance program.
3) Main body side: Turn on the power of LEOPARD, and it enters the download mode.
4) PC side: Check that the tree structure is displayed on the maintenance program.
∗
Be sure to perform step 2) before turning on the power.
FAX-PWB
2
(AR-235/275)
(Files necessary for download)
• Maintenance program: mainte.exe
• Loader files
• IMC loader file: imcbios.cvt
• FAX loader file: faxbios.cvt
The maintenance program performs downloading of the following program:
• FAX program download
Note: The downloaded files such as Printer Control Board file should be copied in the same folder as that of the maintenance program.
When the tree is displayed, downloading can be performed.
(Double-click to perform.)
5) PC side: Double-click Special in the main tree items to extend the sub tree items, then double-click All Area Download.
6) PC side: The maintenance program asks the file name. Specify a download file (*.dat).
Download file:
• leopXXXX.dat: File for collective download (IMC, FAX)
XXXX: Release version (Leop0114.dat, etc.)
7) PC side: When a download file is specified, the downloading procedure advances automatically.
Time required for downloading is as follows:
• Main body program download time: About 5 min
• FAX program download time: About 5 min
8) PC side: When the message below is displayed, downloading is completed.
End message: Download Complete
9) After-process: Terminate the maintenance program, and turn off and on the power of the main body.
With the above procedures, downloading is completed.
AR-FX4 FLASH ROM VERSION UP PROCEDURE - 1
2. Others (Error list)
The list below describes errors occurring during download and countermeasures.
No
01
02
03
04
05
06
Error message Descriptions
COM Port Open Error !
This error message is displayed when a COM port which is disabled is selected or when there is an abnormal
COM port.
TimeOut Error !
Receive Error !
Panel Size Error !
Destination Error !
Printer Control Board
FirmWare Download
Send Error !
[Countermeasures]
Select another COM port which is enable. Check if there is any software which is using the COM port.
This error message is displayed when no response is sent back from the remote party for 10 sec.
[Countermeasures]
Once reset the maintenance software and the machine, then download again.
This error message is displayed when data received from the remote party are abnormal.
[Countermeasures]
Once reset the maintenance software and the machine, then download again.
This error message is displayed when the download file size is specified to 8MB though the machine panel is of
4MB size.
[Countermeasures]
Specify a download size suitable for the machine panel size, and download again.
This error message is displayed when the destination of the machine panel does not coincide with that of the download file.
[Countermeasures]
Specify the download file suitable for the destination of the machine panel, and download again.
This error message is displayed when an error occurs during downloading of the printer control board firmware.
[Countermeasures]
Execute SIM 67-14 on the machine panel to check that "Please Send Data" is displayed, and download again.
AR-FX4 FLASH ROM VERSION UP PROCEDURE - 2
[9] TROUBLE CODE LIST
1. Machine trouble codes
Trouble code
Main code
Sub code
F6
Details of trouble
00 Content F6-**: MCU-FAX communication trouble
Detail Communication setup error/framing/parity/ protocol error
Cause FAX control PWB connector disconnection
Check and remedy
Defective harness between FAX control
PWB and MCU PWB
Motherboard connector pin breakage
FAX control PWB ROM error/Data error
Check connector/harness of FAX control
PWB and MCU PWB.
Check the grounding of the copier.
Check FAX control PWB ROM.
10 Content FAX control PWB trouble
Detail Communication trouble between MCU and
FAX control PWB
Cause FAX control PWB connector disconnection
Defective harness between FAX control
PWB and MCU PWB
Motherboard connector pin breakage
FAX control PWB ROM error/Data error
Check and remedy
Check connector/harness of FAX control
PWB and MCU PWB.
Check the grounding of the copier.
Check FAX control PWB ROM.
80 Content FAX control PWB communication trouble
(Protocol)
Detail Communication trouble between MCU and
FAX control PWB (Protocol error)
Cause FAX control PWB connector disconnection
Defective harness between FAX control
PWB and MCU PWB
Motherboard connector pin breakage
FAX control PWB ROM error/Data error
Check and remedy
Check connector/harness of FAX control
PWB and MCU PWB.
Check the grounding of the copier.
Check FAX control PWB ROM.
81 Content FAX control PWB communication trouble
(Parity)
Detail Communication trouble between MCU and
FAX control PWB (Parity error)
Cause FAX control PWB connector disconnection
Defective harness between FAX control
PWB and MCU PWB
Motherboard connector pin breakage
FAX control PWB ROM error/Data error
Check and remedy
Check connector/harness of FAX control
PWB and MCU PWB.
Check the grounding of the copier.
Check FAX control PWB ROM.
Trouble code
Main Sub code
F6 code
Details of trouble
82 Content FAX control PWB communication trouble
(Over-run)
Detail Communication trouble between MCU and
FAX control PWB (Overrun error)
Cause FAX control PWB connector disconnection
Defective harness between FAX control
PWB and MCU PWB
Motherboard connector pin breakage
FAX control PWB ROM error/Data error
Check connector/harness of FAX control Check and remedy
PWB and MCU PWB.
Check the grounding of the copier.
Check FAX control PWB ROM.
84 Content FAX control PWB communication trouble
(Framing)
Detail Communication trouble between MCU and
FAX control PWB (Framing error)
Cause FAX control PWB connector disconnection
Defective harness between FAX control
PWB and MCU PWB
Motherboard connector pin breakage
FAX control PWB ROM error/Data error
Check and remedy
Check connector/harness of FAX control
PWB and MCU PWB.
Check the grounding of the copier.
Check FAX control PWB ROM.
88 Content FAX control PWB communication trouble
(Timeout)
Detail Communication trouble between MCU and
FAX control PWB (Timeout error)
Cause FAX control PWB connector disconnection
Defective harness between FAX control
PWB and MCU PWB
Motherboard connector pin breakage
FAX control PWB ROM error/Data error
Check and remedy
Check connector/harness of FAX control
PWB and MCU PWB.
Check the grounding of the copier.
Check FAX control PWB ROM.
99 Content Machine-FAX board language error
Detail The machine language setup does not coincide with the FAX board language setup.
Cause FAX board correction error
SIM setup error
Check and remedy
Check the firmware of the FAX board and the combination of the panel screen data, and download the correct version, if necessary.
Check the machine language information.
(Machine language setup:SIM 26-22)
AR-FX4 TROUBLE CODE LIST - 1
2. Communication result code
Described on the communication report table, the communication management table, and the protocol communication report table when communication is completed.
A. Composition of communication report code
Communication result X X (X X X X)
Upper 2 digits of a communication result code: Communication report code of 00 - 90 (Refer to the list of communication report codes.)
Lower 4 digits of a communication result code: Codes used by serviceman.
Top 2 digits Communication report sub code 1 (Refer to the list of communication sub code 1.)
Bottom 2 digits Communication report sub code 2 (Refer to the list of communication sub code 2.)
Note) Communication report sub code 1 and sub code 2 are in hexadecimal. (The others are in decimal.)
< Communication result code list>
25
26
27
28
21
22
23
24
29
30
31
17
18
19
20
13
14
15
16
9
10
11
12
7
8
5
6
Result code
0
3
4
1
2
Final reception signal
(Transmitting side)
Abnormal signal
NSF, DIS
CFR
FTT
MCF
PIP, PIN
RTN, RTP
No signal, DCN
PPR
RNR
CTR
ERR
Abnormal signal
NSF, DIS
CFR
FTT
MCF
PIP, PIN
RTN, RTP
No signal, DCN
PPR
RNR
CTR
ERR
V.8 Phase-1
V.8 Phase-2
V.8 Phase-3
Final reception signal
(Receiving side)
Abnormal signal
(SID), (SUB), NSS, DCS
(PWD), (SEP), NSC, DTC
EOP
EOM
MPS
PRI-Q
DCN
PPS-EOP
PPS-EOM
PPS-MPS, PPS-NULL
RR
CTC
EOR-Q
PPS-PRI-Q
Abnormal signal
SID, SUB, NSS, DCS
PWD, SEP, NSC, DTC
PPS-EOP
PPS-EOM
PPS-MPS, PPS-NULL
PRI-Q
DCN
RR
CTC
EOR-Q
PPS-PRI-Q
V.8 Phase-1
V.8 Phase-2
V.8 Phase-3
(Note) For result codes 16 - 31, V.34 mode communication.
For 32 or later, refer to the table below.
<Communication result code list>
Result code
(Communication result)
0 – 31
33
34
35
38
42
44
46
48
49
50
51
56
Communication report result column
Refer to the previous table.
Busy
Cancel
Power OFF
Reception memory over
Reception length over
Communication interruption content
Depends on the communication disconnection position. For 16 or later, V.34 mode communication.
The calling side cannot connect the line with the other party.
When a communication interruption command is delivered during transmission or reception, <Send/Receive/
Poll/Bulletin>
When the operation is interrupted by the stop key.
When the power is cur off during sending or receiving,
<Send/Receive/Poll/Bulletin>
When memory is over during reception, <Receive/Poll>.
When printing cannot be performed during reception due to inhibition of proxy reception, <Receive/Poll>
When the received data length of one page exceeds the range during reception, <Receive/
Poll>
Document error When a document jam occurs during direct transmission,
<Send>
No response from the other party
When the FAX signal from the other party is not detected within T1 time, <Send/Poll>
OK
The other party has no polling function.
Communication normal end
When the called side has no polling function in polling reception, <Poll>
When the called side has no transmission data, <Bulletin>
Polling is not accepted.
Polling allow number discrepancy
Interface not accepted
When DCN is received for
DTC in polling reception,
<Poll>
When there is no transmission data in polling transmission,
<Bulletin>
When the allow number does not coincide in polling transmission, <Bulletin>
When the system number does not coincide in polling transmission, <Bulletin>
1) When DCN is received for
NSS in transmission of the relay instruction, <Send>
2) When a receiving station number that is not registered is instructed in reception of the relay instruction, <Receive>
3) When F code relay instruction is received during F code relay broadcasting, <Receive>
AR-FX4 TROUBLE CODE LIST - 2
Result code
(Communication result)
59
60
Communication report result column
The other party has no function of F code bulletin board.
F code polling is not accepted.
Communication interruption content
When the other party machine does not have DIS bit 47
(Selective polling function) in F code polling (ringing), <Poll>
When DCN is received for SEP in F code polling (ringing),
<Poll>
When there is no transmission data for SEP in bulletin board,
<Bulletin>
61
62
63
64
F code bulletin board number discrepancy
F code bulletin board password discrepancy
The other party has no function of F code.
F code is not accepted.
When the sub address (bulletin board number (SEP)) does not coincide in bulletin board,
<Bulletin>
When the pass code (PWD) does not coincide in bulletin board, <Bulletin>
When the other party machine does not have DIS bit 49 (sub address capacity) in F code transmission, <Send>. Check that the other party machine conforms to F code.
When F code is transmitted,
<Send>
1) When DCN is received for
SUB, check the BOX number.
2) When DCN is received for
SID, check BOX number and the pass code.
When F code is received,
<Receive>
When the F code relay broadcast function or the F code confidential reception function is inhibited with soft switches.
67 F code password discrepancy
When the pass code (SID) does not coincide in F code reception, <Receive>
68 BOX NO. NG When a BOX number that is not registered is instructed
(SUB discrepancy) in F code reception, <Receive>
• When communication result is OK, the communication result sub code 1 and sub code 2 are 0000.
• < > indicates the communication means. <Send>, send; <Receive>, receive; <Poll>, polling; <Bulletin>, bulletin board
The status code from the modem in V.34 mode is indicated with the communication result sub code 1 (top 2 digits). However, the communication sub code 1 is 00 in communication other than V.34 mode.
<Communication result sub code list 1 >
Code
(Hexadecimal)
21
22
23
24
25
26
27
28
29
2A
2B
2C
31
91
92
93
94
95
97
98
A1
B0
B1
B2
B3
B4
B5
B6
C0
C1
C2
C3
C4
C5
C7
D0
D1
D2
D3
D4
D5
D6
D8
DA
DB
Phase 2
Control channel
Primary channel resync
Phase 3
Phase 4
Descriptions
Timeout standby for INFO0
Check sum error in INFO0
Timeout standby for tone A or B
Timeout standby for the first phase reversion
Timeout standby for cut off tone probing
Timeout standby for the second phase reversion
Timeout standby for probing end
Timeout standby for the third phase reversion
Timeout standby for INFO1
Check sum error in INFO1
Tone found before INFO1
Unexpected INFO0 found
Timeout standby for turning off the reception control channel
Error in the first CC train
Timeout standby for PPh
Tone A/B detected in CC retrain
Timeout standby for ALT
Ach found
Timeout standby for turning off CC
FED OFF with CC data
A trouble which cannot be solved in phase 2. Retrain is forcibly made.
Trouble in S sequence of HDXresync
FED OFF in S sequence of HDXresync
Unexpected completion of S sequence in HDX-resync
Timeout standby for S-Sbar in
HDX-resync
Timeout standby for S-Sbar in
HDX-resync
Timeout standby for S in HDXresync
Timeout for sync with PP
Trouble in S sequence of phase 3
FED OFF in S sequence of phase 3
Unexpected completion of S sequence
Timeout standby for S-Sbar of phase 3
Timeout standby for S-Sbar of phase 3
Timeout standby for S of phase 3
Training due to TRN failure
Trouble in S sequence of phase 4
FED OFF in S sequence of phase 4
Unexpected completion of S sequence
Timeout standby for S-Sbar of phase 4
Timeout standby for S-Sbar of phase 4
Timeout standby for S of phase 4
Timeout standby for MP
Timeout standby for E
Timeout at renegotiation of the transmitter rate
Timeout at MPh of the transmitter
AR-FX4 TROUBLE CODE LIST - 3
Code
(Hexadecimal)
E2
E3
E4
FE
FF
71
96
61
Descriptions
Retrain Retrain detected in phase 2
Retrain detected in phase 3
Retrain detected in phase 4
DTR OFF in retrain
TX setup port flag
Writing is not made to the first mapping frame.
Clear down PSTN clear down request is made.
HDLC The transmitter sends HDLC abort in underflow state.
<Communication result sub code 2 >
Result code 2
02
03
05
06
07
11
12
13
14
20
21
22
23
24
25
26
28
Communication interruption content
EOL time over
Carrier detection time over
Time-up in phase C (8min)
Memory image decoding error
Memory image decoding error
Polarity reversion detection
Invalid command reception
Time over (1min timer/6sec timer)
PUT error
Polarity reversion detection
Invalid command reception
Fall back retry number over
Resend over of the number of times of command retry
Time over (T5 timer)
Time over (T5 timer) in V.34 mode
Time over occurrence during shift from
Primary to Control in V.34 mode
Modem chip answering NG
Transmission/
Reception
Reception
Reception
Transmission
Reception
Transmission
Reception
Reception
Reception
Reception
Transmission
Transmission
Transmission
Transmission
Transmission
Transmission
Transmission
Transmission/
Reception
3. List of buzzer sounds in case of FAX abnormality
– : Long sound • : Single sound 3: Pause
Example: In case of TEL/LIU connection abnormality
{{– • • • • •} repeats {Pee • pi • pause • pi • pi • pi • pi}.
Beep sound pattern
– • • •
– • • • •
Information content
Expanded memory connection abnormality
Internal DMA transfer abnormality
– • • • • •
– • • •
– • • • •
– • • • •
TEL/LIU PWB connection abnormality
Program ROM (main section) writing not completed
Program ROM (font section) writing not completed
Work DRAM (IC13, 14) abnormality
Detail Trouble content
Expanded memory insertion abnormality Expanded memory reinsertion
Internal DMA transfer operation abnormality
TEL/LIU PWB is not connected to the main PWB.
Program ROM (main section) data abnormality
Program ROM (font section) data abnormality
Work DRAM abnormality
PWB solder trouble, PWB parts trouble
Download retry
Download retry
– • • • • •
– • • • • • •
– • – –
SRAM (IC41) abnormality 1
SRAM (IC41) abnormality 2
MCU upload no responding MCU PWB does not respond.
IC13, 14: PWB solder trouble, PWB parts trouble
IC41: PWB solder trouble, PWB parts trouble
IC41: PWB solder trouble, PWB parts trouble
MCU PWB - main PWB connection
– • • –
– • • • –
System abnormality 1
System abnormality 2
Various internal operation abnormality
Various internal operation abnormality
PWB solder trouble, PWB parts trouble
PWB solder trouble, PWB parts trouble
AR-FX4 TROUBLE CODE LIST - 4
[10] ELECTRICAL SECTION
1. Block diagram
A. Main block diagram
PCL
COPIER
SCANNER
COPIER
PRINTER
COPIER CPU
LINE
EXTERNAL
TELEPHONE
TEL/LIU
PWB
S (1)
SCAN
I/F
S (2)
SUB
SCAN
2/3
MULTI-
PLICATION
FAX UNIT
FAX MAIN PWB
IMAGE PROCESS GA
SCAN PROCESS FLOW
S (3)
SDRAM
CON-
TROL
S (4)
SUB
S (3)
ROTATION
SCAN
SCAN
1/2
MULTI-
PLICATION
S (5)
MN860
65
I/F
CODE/
DECODE
MN86065
P (5)
I/F
P (4)
RESO-
LUTION
CON-
VERSION
P (3)
3 3
P (2)
ROTATION
P (1)
SDRAM
CON-
TROL
PRINT PROCESS FLOW
CPU
I/F
FAX
GA
I/F
DMAC
CON-
TROL
SRAM
CON-
TROL
IMAGE
PROCESS
MEMORY
SRAM
1Mbit
PAGE MEMORY
SDRAM
128Mbit
CPU
(SH7709A)
WORK
MEMORY
SDRAM
16Mbit
MODEM
FM336
PROGRAM
FLASH ROM
16Mb
REGIS-
TRATION
MEMORY
SRAM
2Mbit
IMAGE
MEMORY
(STANDARD)
FLASH ROM
16Mbit
MODEM
CON-
TROL
FAX PROCESS GA
CPU
I/F
IMAGE
GA
I/F
DMAC
CON-
TROL
MN860
65
I/F
CODE/
DECODE
MN86065
RTC
I/F
SRAM
CON-
TROL
IMAGE
PROCESS
MEMORY
SRAM
1Mbit
RTC SPEAKER
IMAGE
MEMORY
(EXPANDED)
FLASH ROM
2MB/4MB/8MB
EXPANSION
CONNECTOR
BUS
BUFFER
AR-FX4 ELECTRICAL SECTION - 1
B. TEL/LIU PWB block diagram
DC SEPARATE
POWER SUPPLY LINE
CONNECTION JACK
CURRENT DETECT SECTION
CML RELAY
ON HOOK
DP TRANSMISSION
CIRCUIT
LINE
CLOSE/
INTERFACE
CIRCUIT
TRANSFORMER
SWITCH CIRCUIT
SECTION
SP
MODEM
33600bps
V.34
ATT (0 – 15db)
PB SIGNAL
GENERATE
SECTION
PROGRAM
CONTROL ROM
FAX CONTROL
SECTION
(CPU, GATE ARRAY)
PSEUDO RBT SOUND
GENERATE SECTION
EXTERNAL
TELEPHONE
JACK
S RELAY
PHOTO
COUPLER
CI DETECT
TRANSFORMER
POWER SOURCE RECIVE CONDITION
AC120V
DC24V
DC5V
DC3.3V
GND
EARTH
TO EACH SECTION
READ SECTION
PRINT SECTION
COPY
CONTROL
SECTION
PRINTER I/F
(OPTION)
AR-FX4 ELECTRICAL SECTION - 2
7
6
5
8
8
7
6
5
8
7
6
5
8
7
6
5
7
6
5
8
3
2
1
4
4
3
2
1
4
3
2
1
4
3
2
1
3
2
1
4
7
6
5
8
3
2
1
4
7
6
5
8
7
6
5
8
7
6
5
8
3
2
1
4
3
2
1
4
3
2
1
4
E
10K R30
10K R20 R(NM) R29
AR-FX4 ELECTRICAL SECTION - 3
8
7
6
5
7
6
5
8
2
1
4
3
3
2
1
4
8
7
6
5
7
6
5
8
2
1
4
3
3
2
1
4
7
6
5
8
3
2
1
4
100K
100K
100K
100K
1K
R228
R229
R227
R226
R61
14 7 14 7 14 7 14 7 14 7 14 7 14 7
14 7
14 7
14 7
SKHU(NM) 1 SW
14 7
AR-FX4 ELECTRICAL SECTION - 4
8 4
1 2
E
14 7
AR-FX4 ELECTRICAL SECTION - 5
14 7
14 7 14 7
GND
GND
GND
2
GND
1
GND
1
14 7
14 7
10K
10K
R248
R247
R235
R234
R236
R233
R238
R237
10K
10K
10K
10K
10K
10K
R243
R242
R241
R244
R245
10K
10K
10K
10K
10K
6
5
7
8
8
7
6
5
8
7
6
5
8
7
6
5
3
2
4
1
4
3
2
1
4
3
2
1
4
3
2
1
AR-FX4 ELECTRICAL SECTION - 6
CD1IRQ-
CD1CLK
CD1RES-
CD1A1
CD1A0
CD1A2
CD1A3
CD1REQD0
CD1REQC0
CD1ACKC0-
CD1ACKD0-
CD1RD-
CD1CS-
CD1WR-
CD1UBE-
CD1D10
CD1D11
CD1D9
CD1D8
CD1D5
CD1D4
CD1D6
CD1D7
CD1D2
CD1D1
CD1D3
CD1D0
CD1D14
CD1D13
CD1D12
CD1D15
M1D11
M1D10
M1D9
M1D8
M1D5
M1D4
M1D6
M1D7
M1D1
M1D2
M1D3
M1D0
M1D13
M1D12
M1D15
M1D14
CDD[0]
CDD[1]
CDD[2]
CDD[3]
GND-280
VDD-279
GND-285
GND-286
CDD[4]
CDD[5]
CDD[6]
CDD[7]
VDD-291
GND-292
CDD[8]
CDD[9]
CDD[10]
CDD[11]
VDD-297
GND-298
VDD-303
VDD-304
CDD[12]
CDD[13]
CDD[14]
CDD[15]
CDACKD_N
CDCLK
CDIRQ
VDD-259
GND-260
CDA[0]
CDA[1]
CDA[2]
CDA[3]
VDD-265
VDD-266
GND-267
GND-268
CDCS_N
CDRD_N
CDWR_N
MD[4]
MD[5]
MD[6]
MD[7]
VDD-241
MD[10]
MD[11]
MD[8]
MD[9]
GND-242
GND-236
GND-247
GND-248
MD[12]
MD[13]
MD[14]
MD[15]
VDD-253
GND-254
VDD-235
VDD-229
VDD-230
MD[0]
MD[1]
MD[2]
MD[3]
TRES_N
CDRES_N
CDUBE_N
CDREQC
CDREQD
GND-274
VDD-273
CDACKC_N
274
275
276
277
272
273
278
279
280
281
282
283
284
285
286
287
288
289
270
271
297
298
299
300
301
302
303
304
293
294
292
295
296
290
291
236
237
238
239
240
241
242
243
232
233
234
235
244
245
246
247
248
249
250
251
230
231
229
254
255
256
257
252
253
258
259
260
261
262
263
264
265
266
267
268
269
TP952
TP947
TP949
TP950
TP948
TP953
TP951
TP954
TP1059
TP1060
TP374
TP364
TP363
TP375
TP1058
TP1057
TP957
TP956
TP958
TP955
TP961
TP962
TP960
TP959
TP360
TP361
TP372
TP359
TP1061
TP428
TP371
TP1062
TP1005
TP1006
TP1004
TP1003
TP998
TP999
TP994
TP997
TP996
TP1000
TP1001
TP1002
TP970
TP995
TP971
TP993
8
7
6
5 4
3
2
1
AR-FX4 ELECTRICAL SECTION - 7
RW (RD/WR-)
DREQ[0]_N
DREQ[1]_N
DRAK[0]_N
DRAK[1]_N
BSSEL[0]
BSSEL[1]
VDD-126
GND-127
GND-115
VDD-114
IRQ[1]_N
IRQ[0]_N
GND-134
GND-133
GND-138
VDD-137
GND-145
VDD-144
VDD-152
VDD-151
VDD-113
WAIT_N
D[7]
D[6]
145
144
143
142
141
140
139
138
149
148
147
146
137
136
135
134
133
132
131
130
151
150
152
127
126
125
124
129
128
123
122
121
120
119
118
117
116
115
114
113
112
105
104
103
102
101
100
99
98
97
96
95
94
93
92
91
90
84
83
82
81
80
79
78
77
88
87
89
86
85
109
108
107
106
111
110
D[5]
D[4]
D[3]
D[2]
GND-130
D[11]
D[10]
D[9]
D[8]
GND-141
GND-96
GND-95
CS4_N
CS0_N
A[21]
A[20]
A[22]
BS_N
CS6_N
VDD-78
VDD-77
A[15]
A[14]
A[16]
A[13]
A[12]
A[11]
A[10]
A[8]
A[7]
A[9]
A[6]
A[5]
A[4]
A[3]
A[2]
A[1]
WE0_N
RD_N
WE1_N
CLK
GND-116
GND-123
MODE3
D[1]
D[0]
D[13]
D[12]
D[15]
D[14]
GND-148
TP916
A21
A22
A20
TP416
TP690
TP691
0
R212
WE0-
WE1-
RD-
CS6-
BS-
CS4-
CS0-
RD/WR-
WAIT-
DRAK[0]
DRAK[1]
DREQ[1]-
DREQ[0]-
A11
A10
A13
A12
A14
A15
A16
A2
A1
A3
A4
A6
A5
A7
A8
A9
D5
D4
D3
D2
D7
D6
D10
D11
D9
D8
D1
D0
D14
D15
D13
D12
TP684
TP915
IRQ1-
MD3
IRQ0-
CKIO_GA1
TP914
8 4
8 4
8
7
6
5 4
3
2
1
8
7
6
5
7
6
5
8
8
7
6
5
6
5
8
7
4
3
2
1
3
2
1
4
2
1
4
3
4
3
2
1
AR-FX4 ELECTRICAL SECTION - 8
4 11
E E
E
E
E
E
E
AR-FX4 ELECTRICAL SECTION - 9
BSSEL[0]
BSSEL[1]
CLK_SYS
D[2]
D[3]
D[4]
D[5]
GND-285
GND-282
D[6]
D[7]
VDD-289
D[10]
D[11]
D[8]
D[9]
GND-293
GND-290
GND-286
VDD-296
GND-297
VDD-278
GND-279
NC[2]
NC[3]
D[0]
D[1]
GND-275
IRQ[2]_N
D[12]
D[13]
D[14]
D[15]
VDD-303
VDD-304
GND-300
A[12]
A[13]
A[11]
A[2]
A[3]
A[1]
A[4]
A[5]
A[8]
A[9]
A[6]
A[7]
A[10]
A[15]
A[16]
A[14]
VDD-230
VDD-229
GND-247
GND-248
A[22]
A[23]
A[21]
A[24]
A[25]
A[17]
A[18]
A[19]
A[20]
CS5_N
NC[1]
RD_N
BS_N
WE0_N
WE1_N
WAIT_N
VDD-265
VDD-266
GND-267
GND-268
CKIO_GA2
IRQ2-
WE0-
RD-
WE1-
WAIT
BS-
CS5-
0
R217
TP210
D15
D14
D12
D13
A24
A23
A25
A21
A22
A19
A20
A18
A17
215 TP
257
258
256
260
261
259
263
264
262
266
267
265
269
270
268
272
273
271
275
276
274
278
279
277
281
282
280
284
285
283
287
288
286
290
291
289
293
294
292
296
297
295
299
300
298
302
303
304
301
234
235
236
237
230
231
229
232
233
239
240
238
242
243
241
245
246
244
248
249
247
251
252
250
254
255
253
212
213
D1
D0
TP
TP
TP211
D5
D4
D3
D2
TP214
D6
D7
D9
D8
D11
D10
A13
A14
A12
A15
A16
A10
A11
A5
A4
A3
A6
A7
A2
A1
A8
A9
6
5
8
7
4
3
2
1
AR-FX4 ELECTRICAL SECTION - 10
SDRAM_RAS_N
SDRAM_CAS_N
SDRAM_WR_N
SDRAM_DQM0
SDRAM_DQM1
SDRAM_BA[1]
SDRAM_BA[0]
SDRAM_CS_N
SDRAM_CKE
SDRAM_A[3]
SDRAM_A[2]
SDRAM_CLK
SDRAM_A[0]
SDRAM_A[1]
SDRAM_A[4]
GND-134
GND-133
VDD-152
VDD-151
GND-143
VDD-142
MD[14]
MD[13]
MD[15]
MD[11]
MD[10]
MD[12]
GND-125
VDD-114
VDD-113
GND-115
MA[15]
MA[14]
MD[2]
MD[1]
MD[0]
MA[13]
MA[12]
GND-105
CDD[14]
CDD[13]
CDD[12]
CDD[15]
VDD-78
VDD-77
CDD[11]
MA[1]
MA[0]
MA[2]
MA[4]
MA[3]
GND-95
MA[11]
MA[10]
MA[8]
MA[7]
MA[9]
MA[6]
MA[5]
GND-96
MWE_N
MOE_N
GND-87
VDD-86
MCE_N
TRES_N
VDD-104
MD[9]
MD[8]
MD[7]
MD[6]
MD[4]
MD[3]
MD[5]
VDD-124
GND-116
147
146
145
144
142
141
143
151
150
152
149
148
139
138
140
136
135
137
133
132
134
130
129
131
127
126
128
124
123
125
121
120
122
118
117
119
115
114
116
112
111
113
109
108
110
106
105
107
103
102
101
104
94
93
95
91
90
92
99
98
97
96
88
87
89
85
84
86
82
81
83
79
78
77
80
100
MNR14 33
8
9
7
TP196
TP201
TP19
TP19
TP19
TP195
TP200
4
5
3
4 TP19
TP193
TP192
TP20
TP20
TP20
TP206
TP207
2
1
TP833
6
5
7
TP834
TP85
TP85
TP83
TP83
TP83
4
6
7
2 TP20
TP854
TP848
TP84
TP84
TP84
TP845
7
4
9
TP850
1
2
TP853
813
819
818
5
TP
TP
TP29
TP817
TP816
TP
TP843
TP84
TP84
TP82
TP82
TP84
5
6
0
3
1
TP82
TP83
TP82
TP82
TP82
TP822
TP821
0
9
2
9 TP83
TP838
TP840
TP828
TP83
TP82
TP83
7
6
5
8
6
5
8
7
CD2D12
CD2D13
CD2D11
CD2D14
CD2D15
M2A6
M2A5
M2A9
M2A8
M2A7
M2A10
M2A11
M2WE-
M2OE-
M2A4
M2A3
M2A2
M2A1
M2A0
M2A14
M2A15
M2A13
M2A12
M2D1
M2D0
M2D2
M2CE-
M2D5
M2D4
M2D3
M2D8
M2D7
M2D9
M2D6
M2D12
M2D11
M2D10
M2D13
M2D15
M2D14
MNR14 33
MNR14 33
BR82
BR83
6
5
8
7
3
2
1
4
4
3
2
1
8
7
6
5
MNR14 33
4
3
2
1
BR84
4
3
2
1
BR85
792 TP
TP793
TP794
TP
TP
TP
782
781
783
TP780
TP209
784 TP
TP786
TP785
TP
TP
TP
TP790
788
787
789
TP791
SDRAM_BA0
SDRAM_BA1
SDRAM_A2
SDRAM_A3
SDRAM_A4
SDRAM_A0
SDRAM_A1
SDRAM_WR-
SDRAM_CAS-
SDRAM_CLK
SDRAM_CS-
SDRAM_RAS-
SDRAM_CKE
SDRAM_DQM0
SDRAM_DQM1
8
7
6
5
8
7
6
5
6
5
7
8
6
5
7
8
4
3
2
1
4
3
2
1
3
2
4
1
3
2
4
1
AR-FX4 ELECTRICAL SECTION - 11
6
5
7
8
6
5
7
8
8
7
6
5
8
7
6
5
3
2
4
1
3
2
4
1
4
3
2
1
4
3
2
1
8
7
6
5 4
3
2
1
6
8
7
1
E
AR-FX4 ELECTRICAL SECTION - 12
TP1229
TP1228
8
7
6
5
7
6
5
8
8
7
6
5
4
3
2
1
3
2
1
4
4
3
2
1
6.8k
7.5k
10k
AR-FX4 ELECTRICAL SECTION - 13
AR-FX4 ELECTRICAL SECTION - 14
35V 47
µ
AR-FX4 ELECTRICAL SECTION - 15
All rights reserved.
Printed.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic; mechanical; photocopying; recording or otherwise without prior written permission of the publisher.
Trademark Acknowledgments
Microsoft Windows, MS-DOS, Windows NT, Windows 2000 are trademarks of Microsoft
Corporation in the U. S. A. and other countries.
Macintosh, Power Macintosh, Mac OS, LaserWriter, and AppleTalk are registered trademarks of
Apple Computer, Inc.
IBM, PC/ AT, and PowerPC are trademarks of International Business Machines Corporation.
Pentium is a registered trademark of Intel Corporation.
PCL is a trademark of the Hewlett- Packard Company.
PostScript
is a registered trademark of Adobe Systems Incorporated.
NetWare is a registered trademark of Novell, Inc.
All other trademarks and copyrights are the property of their respective owners.
Digital Document Systems Group
Quality & Reliability Control Center
Yamatokoriyama, Nara 639-1186, Japan
2001 June Printed
advertisement
Key Features
- Copy and print
- Fax sending and receiving
- Automatic document feeder
- Multiple resolution settings
- Memory transmission