Zurn ZER 6000AV-CP, ZER 6000AV-CPM, ZER 6003AV-CP, ZER 6003AV-CPM Sensor Operated Flushometer Installation, Operation, Maintenance, and Parts Manual
Below you will find brief information for Sensor Operated Flushometer ZER 6000AV-CP, Sensor Operated Flushometer ZER 6000AV-CPM, Sensor Operated Flushometer ZER 6003AV-CP, Sensor Operated Flushometer ZER 6003AV-CPM. These flushometers are designed for use with closets and urinals, and feature a sensor that activates the flush when a person is detected within range. This makes them ideal for applications where water conservation is a concern. The manual includes instructions on how to install, operate and maintain these flushometers.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
AquaSense AV ZER Series ® Patented and Patents Pending ZER6000AV-CP ZER6000AV-CPM ADA ZER6003AV-CP ZER6003AV-CPM ADA Sensor-Operated, Battery-Powered Closet/Urinal Systems Note: This manual covers all ZER Sensor, Battery Closet/Urinal Systems with -CPM (Chrome-Plated Metal Cover) and -CP (Chrome Plastic Cover) Units. LIMITED WARRANTY All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of purchase. Decorative finishes warranted for one year. We will replace at no cost goods that prove defective provided we are notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are approximate and are not guaranteed. FV237 Page 1 AquaSense Battery Powered Flush Valves/Retrofit Kits Automatic, Sensor-Operated Battery-Powered Flushometer Installation, Operation, Maintenance, and Parts Manual AquaSense Battery Powered Flush Valves/Retrofit Kits PRIOR TO INSTALLATION IMPORTANT: Prior to installing the ZER Flushometer, install the items listed below: • Closet or urinal fixture • Drain line • Water supply line • ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS. • WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE. • FLUSH ALL WATER LINES PRIOR TO OPERATION (SEE STEP 9). • DIRT AND DEBRIS CAN CAUSE FLUSH VALVE TO RUN CONTINUOUSLY. The ZER is designed to operate with 20 to 80 psi (138 to 552 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for pressure requirements. Protect the chrome or special finish of this flushometer. DO NOT USE TOOTHED TOOLS TO INSTALL OR SERVICE THE VALVE. A D A B 1 1 Install stop valve assembly A using proper size supply escutcheon and sweat solder adapter kit if applicable. Thread sealing compounds should be used on male NPT threads only. 3 3 Insert the flush valve tailpiece B into the stop valve A and hand tighten the lock nut D to the stop valve. Plumb the entire unit. B D C E 2 2 Prior to inserting the flush valve tailpiece B into stop valve, be certain that the O-ring seal C is located in O-ring seal groove at the end of the tailpiece, and the locking nut D and locking snap ring E are located as shown. Care should be taken not to damage the O-ring when inserting the tailpiece into the stop valve. If lubrication is needed, wetting the O-ring with water will be sufficient. F 4 4 Determine the length of vacuum breaker tube F required to join the flush valve and fixture spud. Cut the vacuum breaker tube, if required, to this length. Assemble the vacuum breaker tube assembly and spud nut assembly to the flush valve and fixture spud. 5 Hand tighten spud nut and vacuum breaker tube nut to fixture and flush valve. Adjust the valve assembly for plumb. Tighten fixture spud nut, vacuum breaker tube nut and lock nut with a wrench. Do not turn water on until batteries are inserted – see 6. Page 2 FV237 6 ACTIVATION Using supplied battery compartment wrench, remove battery compartment from the E-Z Flush™ unit. AquaSense Battery Powered Flush Valves/Retrofit Kits Load batteries into compartment tray (note position of batteries in tray), and reinstall battery tray into the E-Z Flush unit. Secure tray with battery compartment wrench. The last three turns of the wrench will activate the E-Z Flush unit. The E-Z Flush System is now operational. Your E-Z Flush unit comes preset from the factory. If special circumstances require adjustment of the activation distance, see Item 11 – “Adjusting Your E-Z Flush.” The E-Z Flush unit has a 10-minute start-up sequence in which the sensor will flash the User-In-View yellow L.E.D. continuously as long as a user is in view. After the start-up sequence is completed and when the sensor has a user in view, the User-In-View yellow L.E.D. will flash only 3 times after a 5-second delay. This delay prevents needless flushes when someone walks by. 6 Sensor units should not be located across from each other or in close proximity to highly reflective surfaces. 7 VISUAL INDICATOR GUIDE USER-IN-VIEW L.E.D. Yellow light flashes 3 times – after 5-second delay – when a user is in view. The yellow light flashes constantly when a user is in view during the 10-minute start-up sequence. SENSOR BATTERY L.E.D. Red light flashes indicating it is time to replace batteries with 4 new “C” batteries. COURTESY MANUAL FLUSH BUTTON Allows manual activation of flush when needed. 7 8 Before the supply water is turned on, be sure all stop valves to the flush valves are closed off tight. The stop valves can be opened and closed by using the adjusting screw located at the center of the stop valve cap T , behind the adjusting screw cover if already installed. Stop valve adjustments can only be made by using the adjusting screw. It is not necessary to remove the stop valve cap when making adjustments. If for any reason it becomes necessary to remove the stop valve cap, be certain the water is shut off at the main supply valve. T 8 FV237 Page 3 9 When all flush valves are connected to the fixtures and water pressure AquaSense Battery Powered Flush Valves/Retrofit Kits is available, it is recommended that the supply piping be flushed to remove dirt, pipe chips, etc., from system. Use the following procedure to flush out the supply piping: A. Remove the main valve body cover O and internal plastic cap P . B. Remove the trip mechanism Q from the flush valve and set aside (shown in 9). C. Replace the plastic cover P and main body cover O without reinstalling the trip mechanism Q . D. Open the stop valve by using the stop adjusting screw and flush out all debris from pipe and connections. E. Once pipe and connection are flushed, shut off stop, open cover, reinstall the trip mechanism Q , replace both covers ( O and P ) and tighten. This procedure should also be repeated when the system is drained for seasonal use, as occurs in athletic fields, recreation parks, etc. O Working Parts P New RetroFlush Diaphragm Kit Q 9 10 The ZER flush valves are preset for fixture volume as marked on the valve cartons. The valve does not require regulation for variation in water pressure within its operating range. To set the flush valve for proper operation, gradually adjust the stop valve open, using the adjusting screw, while actuating the valve until the rate of water flow into the fixture is not excessive, yet is sufficient to adequately evacuate the waste. The final setting for urinals should be such that the fixture will not overflow when the valve is actuated in succession. The stop cap screw cover should be replaced after final adjustments have been made. 10 TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION Yellow L.E.D. light flashes 3 times when there are no users. Front of sensor is covered or sensor is set too far out, registering the opposite wall or door as a user. Remove item covering sensor or adjust sensor activation distance. (See 11 – “Adjusting the E-Z Flush.”) Yellow L.E.D. light flashes continuously when sensor is activated by a user. E-Z Flush unit is in 10-minute start-up mode (when first activated). Yellow L.E.D. light will flash only 3 times, acknowledging a user is in view after the 10-minute start-up mode. Red L.E.D. light flashes. Batteries need replacing. Replace batteries. Not enough water to fixture or too much water to fixture. Diaphragm damaged or valve control stop improperly adjusted. Replace diaphragm and/or adjust valve control stop. Valve will not operate. Sensor range set too close to E-Z Flush, batteries are dead, or water supply is turned off. Adjust sensor, replace batteries, or turn water on. If the E-Z Flush does not begin to function, call Customer Service at 1-800-997-3876. Valve does not shut off. Dirt or debris preventing diaphragm from functioning properly. Remove dirt or debris, check by-pass hole in diaphragm. Valve does not flush even after sensor has been adjusted. Batteries are dead. Replace batteries. If the E-Z Flush does not begin to function, call Customer Service at 1-800-997-3876. Page 4 FV237 11 ADJUSTING YOUR E-Z FLUSH AquaSense Battery Powered Flush Valves/Retrofit Kits STEP A Use battery compartment wrench to remove battery compartment tray. STEP B Pull cover off by rotating battery side forward and out. STEP C Sensor Adjustor Tool comes in a builtin storage pocket. Replace after use. WIRING DIAGRAM TO CHANGE ACTIVATION DISTANCE FOR THE SENSOR 1. Remove battery compartment tray as shown in Step 11. 2. Remove cover and sensor adjustor tool as shown in Step 11. 3. Replace battery compartment without cover in E-Z Flush to activate unit (the yellow L.E.D. will flash continuously when it has an object in view for the 10-minute reset period). See Step 6, “Activation.” 4. Have an individual stand at desired activation distance. 5. Use sensor adjustor tool and turn Sensor Range Adjustment Screw all the way down and then turn slowly up until yellow L.E.D. begins to flash. 6. Ensure sensor is not detecting stall door or wall by closing door, stepping out of sensor path and making sure yellow L.E.D. is not flashing. If sensor locks onto door or wall, unit will not flush properly. Shorten activation distance. 7. Remove battery compartment, replace sensor adjustor tool and cover. Replace battery compartment tray to reactivate E-Z Flush unit. 8. After 10-minute start-up sequence, the yellow L.E.D. will flash only 3 times when a user is in view (after a 5-second delay). FV237 Page 5 AquaVantage Exposed E-Z Flush Repair Kits ® AquaSense Battery Powered Flush Valves/Retrofit Kits Parts Identification 1.* 2.* 3. 4.* 5. 6. 7. 8. 9.* 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. Seal Collar Gasket Sensor Module Manual Override Push Button Replacement Sensor Lens Chrome Plastic Cover Chrome Metal Cover Battery Drawer O-Ring Valve Body Cover Plastic Cover Trip Mechanism Diaphragm Repair Kit Valve Body Vacuum Breaker Friction Washer Vacuum Breaker Insert Vacuum Breaker Duckbill Vacuum Breaker Tube Vacuum Breaker Tube Nut Spud Nut Spud Friction Washer Spud Sleeve Spud Escutcheon Tailpiece Snap Ring Tailpiece O-Ring Locking Nut Setscrew for Cast Wall Flange Cast Wall Escutcheon Supply Cover Tube Sweat Solder Adaptor Stop Body Piston Seal Piston Stop Spring 41. Guide O-Ring 42. Piston Guide 43. Guide Holder 44. Adjusting Screw 45. Stop Cap Snap Cap Screw Cover Vandal-Resistant Control Stop Cover Setscrew for Control Stop Cover Handle Nut Wrench Allen Wrench Covers and Repair Kits Outside Cover - CP – Item 10 Inside Cover – Item 11 Low Consumption Closet Kit – 1.6 gal. flush Water Saving Closet Kit – 3.5 gal. flush Full Flow Closet Kit – 4.5 gal. flush Low Consumption Urinal Kit – 1.0 gal. flush Water Saving Urinal Kit – 1.5 gal. flush Full Flush Urinal Kit – 3.0 gal. flush Product No. P6000-LL-CP P6000-L P6000-ECA-WS1 P6000-ECA-WS P6000-ECA-FF P6000-EUA-WS1 P6000-EUA-WS P6000-EUA-FF Repair Parts – Inside Parts Urinal Relief Valve – Item 12 Closet Relief Valve – Item 12 Product No. P6000-EU13 P6000-EC13 AquaVantage Rebuild Kits Closet and Urinal Rebuild Kits Include Items 12, 13, 15-17, 26 Product No. P6000-ECA-WS-RK P6000-ECA-WS1-RK P6000-EUA-WS-RK P6000-EUA-WS1-RK Handle Assembly and Repair Kits Chrome Plastic Cover – Item 6 Chrome Metal Cover – Item 7 Replacement Sensor Lens – Item 5 Battery Drawer – Item 8 *Repair Kit Includes Item 1, Item 2, Item 4 and Item 9 Sensor Module Product No. PERK6000-L-CPCR PERK6000-L-CPMCR PERK6000-SCR PERK6000-BD PERK6000-RK PERK6000-SR Control Stop Repair Kit and Parts Control Stop Repair Kit for 1" and 3⁄4", Includes Items 33-39 Seal Seat for 1" and 3⁄4", Includes Item 33 VP Control Stop Repair Kit for 1" and 3⁄4", Includes Items 33-39 Sweat Solder Connection with Cast Wall Flange, Includes Items 29-31 Product No. Adjustable Tailpieces Adjustable Tailpiece for Standard Flush Valve, Includes Items 24-26 Tailpiece Coupling Assembly, Includes Items 25-27 Tailpiece Locking Ring, Includes Item 25 Tailpiece O-Ring, Includes Item 26 Coupling Nut, Includes Item 27 Product No. Flush Connections and Spud Coupling Kits Flush Tube Assembly for Flush Valves, Includes Items 15-19. Specify diameter and length. Vacuum Breaker Repair Kit, Includes Items 15-17 Spud Coupling Assembly, Includes Items 20-23. Specify size. Product No. P6000-D-SD P6000-D42 P6000-D-VP P6000-YBYC P6000-J1 P6000-K P6000-C30 P6000-C31 P6000-C32 P6000-A P6000-B P6000-H ZURN INDUSTRIES, INC. COMMERCIAL BRASS OPERATION 5900 ELWIN BUCHANAN DRIVE, SANFORD, NC, U.S.A. 27330, PHONE: 1-800-997-3876, FAX: 919/775-3541, WEBSITE: www.zurn.com IN CANADA: ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE, MISSISSAUGA, ONTARIO L4V 1L2, PHONE: 905/405-8272, FAX: 905/405-1292 © 2004 Zurn Industries, Inc. Printed in the U.S.A. Form No. FV237, 6/04
advertisement
Key Features
- Sensor-operated activation
- Battery powered
- Water conservation
- Easy installation
- Adjustable flush settings
- Low maintenance
- Manual flush activation
- LED indicator for battery status