Zurn ZER 6000AV-CP, ZER 6000AV-CPM, ZER 6003AV-CP, ZER 6003AV-CPM Sensor Operated Flushometer Installation, Operation, Maintenance, and Parts Manual

Zurn ZER 6000AV-CP, ZER 6000AV-CPM, ZER 6003AV-CP, ZER 6003AV-CPM Sensor Operated Flushometer Installation, Operation, Maintenance, and Parts Manual

Below you will find brief information for Sensor Operated Flushometer ZER 6000AV-CP, Sensor Operated Flushometer ZER 6000AV-CPM, Sensor Operated Flushometer ZER 6003AV-CP, Sensor Operated Flushometer ZER 6003AV-CPM. These flushometers are designed for use with closets and urinals, and feature a sensor that activates the flush when a person is detected within range. This makes them ideal for applications where water conservation is a concern. The manual includes instructions on how to install, operate and maintain these flushometers.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Zurn ZER 6000AV-CP, 6000AV-CPM, 6003AV-CP, 6003AV-CPM Installation Manual | Manualzz
AquaSense AV
ZER Series
®
Patented and Patents Pending
ZER6000AV-CP
ZER6000AV-CPM
ADA
ZER6003AV-CP
ZER6003AV-CPM
ADA
Sensor-Operated, Battery-Powered
Closet/Urinal Systems
Note: This manual covers all ZER Sensor,
Battery Closet/Urinal Systems with
-CPM (Chrome-Plated Metal Cover) and
-CP (Chrome Plastic Cover) Units.
LIMITED WARRANTY
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of purchase.
Decorative finishes warranted for one year. We will replace at no cost goods that prove defective provided we are notified in writing of such defect and
the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in accordance with instructions.
We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental or consequential damages. The sole and
exclusive remedy shall be limited to the replacement of the defective goods. Before installation and use, the purchaser shall determine the suitability
of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied
warranty of merchantability is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is
limited to a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are
approximate and are not guaranteed.
FV237 Page 1
AquaSense Battery
Powered Flush
Valves/Retrofit Kits
Automatic, Sensor-Operated
Battery-Powered Flushometer
Installation, Operation,
Maintenance, and Parts Manual
AquaSense Battery
Powered Flush
Valves/Retrofit Kits
PRIOR TO INSTALLATION
IMPORTANT:
Prior to installing the ZER Flushometer, install the items listed below:
• Closet or urinal fixture
• Drain line
• Water supply line
• ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH APPLICABLE
CODES AND REGULATIONS.
• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME
OF WATER FOR EACH FIXTURE.
• FLUSH ALL WATER LINES PRIOR TO OPERATION (SEE STEP 9).
• DIRT AND DEBRIS CAN CAUSE FLUSH VALVE TO RUN CONTINUOUSLY.
The ZER is designed to operate with 20 to 80 psi (138 to 552 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED
BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for pressure requirements.
Protect the chrome or special finish of this flushometer. DO NOT USE TOOTHED TOOLS TO INSTALL OR SERVICE THE VALVE.
A
D
A
B
1
1 Install stop valve assembly A using proper size supply escutcheon
and sweat solder adapter kit if applicable. Thread sealing compounds
should be used on male NPT threads only.
3
3 Insert the flush valve tailpiece B into the stop valve A and hand
tighten the lock nut D to the stop valve. Plumb the entire unit.
B
D
C
E
2
2 Prior to inserting the flush valve tailpiece B into stop valve, be certain
that the O-ring seal C is located in O-ring seal groove at the end of
the tailpiece, and the locking nut D and locking snap ring E are
located as shown. Care should be taken not to damage the O-ring
when inserting the tailpiece into the stop valve. If lubrication is needed,
wetting the O-ring with water will be sufficient.
F
4
4 Determine the length of vacuum breaker tube F required to join the
flush valve and fixture spud. Cut the vacuum breaker tube, if required,
to this length. Assemble the vacuum breaker tube assembly and spud
nut assembly to the flush valve and fixture spud.
5 Hand tighten spud nut and vacuum breaker tube nut to fixture and flush
valve. Adjust the valve assembly for plumb. Tighten fixture spud nut,
vacuum breaker tube nut and lock nut with a wrench. Do not turn
water on until batteries are inserted – see 6.
Page 2 FV237
6 ACTIVATION
Using supplied battery compartment wrench,
remove battery compartment from the
E-Z Flush™ unit.
AquaSense Battery
Powered Flush
Valves/Retrofit Kits
Load batteries into compartment tray
(note position of batteries in tray), and
reinstall battery tray into the E-Z Flush unit.
Secure tray with battery compartment wrench. The last three turns of
the wrench will activate the E-Z Flush unit. The E-Z Flush System is
now operational.
Your E-Z Flush unit comes preset from the factory. If special circumstances
require adjustment of the activation distance, see Item 11 – “Adjusting
Your E-Z Flush.”
The E-Z Flush unit has a 10-minute start-up sequence in which the sensor
will flash the User-In-View yellow L.E.D. continuously as long as a user is
in view. After the start-up sequence is completed and when the sensor
has a user in view, the User-In-View yellow L.E.D. will flash only 3 times
after a 5-second delay. This delay prevents needless flushes when
someone walks by.
6
Sensor units should not be located across from each other or in close
proximity to highly reflective surfaces.
7 VISUAL INDICATOR GUIDE
USER-IN-VIEW L.E.D. Yellow light flashes 3 times – after 5-second
delay – when a user is in view. The yellow light flashes constantly
when a user is in view during the 10-minute start-up sequence.
SENSOR
BATTERY L.E.D. Red light flashes indicating it is time to replace batteries
with 4 new “C” batteries.
COURTESY MANUAL FLUSH BUTTON Allows manual activation of flush
when needed.
7
8 Before the supply water is turned on, be sure all stop valves to the
flush valves are closed off tight. The stop valves can be opened and
closed by using the adjusting screw located at the center of the stop
valve cap T , behind the adjusting screw cover if already installed.
Stop valve adjustments can only be made by using the adjusting screw.
It is not necessary to remove the stop valve cap when making
adjustments. If for any reason it becomes necessary to remove
the stop valve cap, be certain the water is shut off at the main
supply valve.
T
8
FV237 Page 3
9 When all flush valves are connected to the fixtures and water pressure
AquaSense Battery
Powered Flush
Valves/Retrofit Kits
is available, it is recommended that the supply piping be flushed to remove
dirt, pipe chips, etc., from system.
Use the following procedure to flush out the supply piping:
A. Remove the main valve body cover O and internal plastic cap P .
B. Remove the trip mechanism Q from the flush valve and set aside
(shown in 9).
C. Replace the plastic cover P and main body cover O without reinstalling the trip mechanism Q .
D. Open the stop valve by using the stop adjusting screw and flush out
all debris from pipe and connections.
E. Once pipe and connection are flushed, shut off stop, open cover,
reinstall the trip mechanism Q , replace both covers ( O and P )
and tighten.
This procedure should also be repeated when the system is drained for
seasonal use, as occurs in athletic fields, recreation parks, etc.
O
Working Parts
P
New RetroFlush
Diaphragm Kit
Q
9
10 The ZER flush valves are preset for fixture volume as marked on the
valve cartons. The valve does not require regulation for variation in
water pressure within its operating range. To set the flush valve for
proper operation, gradually adjust the stop valve open, using the adjusting
screw, while actuating the valve until the rate of water flow into the
fixture is not excessive, yet is sufficient to adequately evacuate the
waste. The final setting for urinals should be such that the fixture will
not overflow when the valve is actuated in succession. The stop cap
screw cover should be replaced after final adjustments have been made.
10
TROUBLESHOOTING GUIDE
PROBLEM
CAUSE
SOLUTION
Yellow L.E.D. light flashes 3 times
when there are no users.
Front of sensor is covered or sensor is set too far
out, registering the opposite wall or door as a user.
Remove item covering sensor or adjust sensor activation
distance. (See 11 – “Adjusting the E-Z Flush.”)
Yellow L.E.D. light flashes
continuously when sensor
is activated by a user.
E-Z Flush unit is in 10-minute start-up mode
(when first activated).
Yellow L.E.D. light will flash only 3 times, acknowledging
a user is in view after the 10-minute start-up mode.
Red L.E.D. light flashes.
Batteries need replacing.
Replace batteries.
Not enough water to fixture
or too much water to fixture.
Diaphragm damaged or valve control stop
improperly adjusted.
Replace diaphragm and/or adjust valve control stop.
Valve will not operate.
Sensor range set too close to E-Z Flush, batteries
are dead, or water supply is turned off.
Adjust sensor, replace batteries, or turn water on. If the
E-Z Flush does not begin to function, call Customer Service
at 1-800-997-3876.
Valve does not shut off.
Dirt or debris preventing diaphragm from
functioning properly.
Remove dirt or debris, check by-pass hole in diaphragm.
Valve does not flush even after
sensor has been adjusted.
Batteries are dead.
Replace batteries. If the E-Z Flush does not begin to function,
call Customer Service at 1-800-997-3876.
Page 4 FV237
11 ADJUSTING YOUR E-Z FLUSH
AquaSense Battery
Powered Flush
Valves/Retrofit Kits
STEP A Use battery compartment wrench to
remove battery compartment tray.
STEP B Pull cover off by rotating battery side
forward and out.
STEP C Sensor Adjustor Tool comes in a builtin storage pocket. Replace after use.
WIRING DIAGRAM
TO CHANGE ACTIVATION DISTANCE FOR THE SENSOR
1. Remove battery compartment tray as shown in Step 11.
2. Remove cover and sensor adjustor tool as shown in Step 11.
3. Replace battery compartment without cover in E-Z Flush to activate unit (the yellow L.E.D. will flash continuously when it has an object in view for the
10-minute reset period). See Step 6, “Activation.”
4. Have an individual stand at desired activation distance.
5. Use sensor adjustor tool and turn Sensor Range Adjustment Screw all the way down and then turn slowly up until yellow L.E.D. begins to flash.
6. Ensure sensor is not detecting stall door or wall by closing door, stepping out of sensor path and making sure yellow L.E.D. is not flashing. If sensor
locks onto door or wall, unit will not flush properly. Shorten activation distance.
7. Remove battery compartment, replace sensor adjustor tool and cover. Replace battery compartment tray to reactivate E-Z Flush unit.
8. After 10-minute start-up sequence, the yellow L.E.D. will flash only 3 times when a user is in view (after a 5-second delay).
FV237 Page 5
AquaVantage Exposed E-Z Flush Repair Kits
®
AquaSense Battery
Powered Flush
Valves/Retrofit Kits
Parts Identification
1.*
2.*
3.
4.*
5.
6.
7.
8.
9.*
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
Seal
Collar Gasket
Sensor Module
Manual Override Push Button
Replacement Sensor Lens
Chrome Plastic Cover
Chrome Metal Cover
Battery Drawer
O-Ring
Valve Body Cover
Plastic Cover
Trip Mechanism
Diaphragm Repair Kit
Valve Body
Vacuum Breaker Friction Washer
Vacuum Breaker Insert
Vacuum Breaker Duckbill
Vacuum Breaker Tube
Vacuum Breaker Tube Nut
Spud Nut
Spud Friction Washer
Spud Sleeve
Spud Escutcheon
Tailpiece
Snap Ring
Tailpiece O-Ring
Locking Nut
Setscrew for Cast Wall Flange
Cast Wall Escutcheon
Supply Cover Tube
Sweat Solder Adaptor
Stop Body
Piston Seal
Piston
Stop Spring
41.
Guide O-Ring
42.
Piston Guide
43.
Guide Holder
44.
Adjusting Screw
45.
Stop Cap
Snap Cap Screw Cover
Vandal-Resistant Control Stop Cover
Setscrew for Control Stop Cover
Handle Nut Wrench
Allen Wrench
Covers and Repair Kits
Outside Cover - CP – Item 10
Inside Cover – Item 11
Low Consumption Closet Kit – 1.6 gal. flush
Water Saving Closet Kit – 3.5 gal. flush
Full Flow Closet Kit – 4.5 gal. flush
Low Consumption Urinal Kit – 1.0 gal. flush
Water Saving Urinal Kit – 1.5 gal. flush
Full Flush Urinal Kit – 3.0 gal. flush
Product No.
P6000-LL-CP
P6000-L
P6000-ECA-WS1
P6000-ECA-WS
P6000-ECA-FF
P6000-EUA-WS1
P6000-EUA-WS
P6000-EUA-FF
Repair Parts – Inside Parts
Urinal Relief Valve – Item 12
Closet Relief Valve – Item 12
Product No.
P6000-EU13
P6000-EC13
AquaVantage Rebuild Kits
Closet and Urinal Rebuild Kits Include
Items 12, 13, 15-17, 26
Product No.
P6000-ECA-WS-RK
P6000-ECA-WS1-RK
P6000-EUA-WS-RK
P6000-EUA-WS1-RK
Handle Assembly and Repair Kits
Chrome Plastic Cover – Item 6
Chrome Metal Cover – Item 7
Replacement Sensor Lens – Item 5
Battery Drawer – Item 8
*Repair Kit Includes Item 1, Item 2, Item 4 and Item 9
Sensor Module
Product No.
PERK6000-L-CPCR
PERK6000-L-CPMCR
PERK6000-SCR
PERK6000-BD
PERK6000-RK
PERK6000-SR
Control Stop Repair Kit and Parts
Control Stop Repair Kit for 1" and 3⁄4",
Includes Items 33-39
Seal Seat for 1" and 3⁄4", Includes Item 33
VP Control Stop Repair Kit for 1" and 3⁄4",
Includes Items 33-39
Sweat Solder Connection with Cast Wall Flange,
Includes Items 29-31
Product No.
Adjustable Tailpieces
Adjustable Tailpiece for Standard Flush Valve,
Includes Items 24-26
Tailpiece Coupling Assembly, Includes Items 25-27
Tailpiece Locking Ring, Includes Item 25
Tailpiece O-Ring, Includes Item 26
Coupling Nut, Includes Item 27
Product No.
Flush Connections and Spud Coupling Kits
Flush Tube Assembly for Flush Valves, Includes Items 15-19.
Specify diameter and length.
Vacuum Breaker Repair Kit, Includes Items 15-17
Spud Coupling Assembly, Includes Items 20-23.
Specify size.
Product No.
P6000-D-SD
P6000-D42
P6000-D-VP
P6000-YBYC
P6000-J1
P6000-K
P6000-C30
P6000-C31
P6000-C32
P6000-A
P6000-B
P6000-H
ZURN INDUSTRIES, INC. COMMERCIAL BRASS OPERATION
5900 ELWIN BUCHANAN DRIVE, SANFORD, NC, U.S.A. 27330, PHONE: 1-800-997-3876, FAX: 919/775-3541, WEBSITE: www.zurn.com
IN CANADA: ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE, MISSISSAUGA, ONTARIO L4V 1L2, PHONE: 905/405-8272, FAX: 905/405-1292
© 2004 Zurn Industries, Inc.
Printed in the U.S.A.
Form No. FV237, 6/04

advertisement

Key Features

  • Sensor-operated activation
  • Battery powered
  • Water conservation
  • Easy installation
  • Adjustable flush settings
  • Low maintenance
  • Manual flush activation
  • LED indicator for battery status

Frequently Answers and Questions

How do I install a ZER flushometer?
The installation process is outlined in the manual. It includes steps for connecting the flushometer to the water supply, fixture, and drain line. Refer to the specific instructions for your model.
What kind of batteries does the ZER flushometer use?
It uses 'C' batteries. The manual provides details on battery replacement and the battery status indicator.
How do I adjust the flush volume for the ZER flushometer?
To adjust flush volume, you'll need to use the stop valve adjusting screw. Be sure to check the manual for detailed instructions.