Cisco IE 4010 16S12P, 4S24P network switch Hardware Installation Guide

Cisco IE 4010 16S12P, 4S24P network switch Hardware Installation Guide
Add to My manuals

Cisco IE 4010 16S12P and IE 4010 4S24P are industrial-grade network switches, designed for harsh environments. They offer a combination of reliability, security, and manageability, making them suitable for applications like process manufacturing, utility substations, and intelligent transportation systems.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Cisco IE 4010 Switch Hardware Installation Guide | Manualzz

Cisco IE 4010 Switch Hardware Installation

Guide

First Published:

September 2016

Last Updated:

September 2016

Cisco Systems, Inc.

www.cisco.com

THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE

WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE

ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL

RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.

THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE INCORPORATED HEREIN BY

THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR

CISCO REPRESENTATIVE FOR A COPY.

The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.

The following information is for FCC compliance of Class B devices: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by turning the equipment off and on, users are encouraged to try to correct the interference by using one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product.

The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California,

Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981,

Regents of the University of California.

NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE

PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED

OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND

NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.

IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL

DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR

INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH

DAMAGES.

Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.

All printed copies and duplicate soft copies are considered un-Controlled copies and the original on-line version should be referred to for latest version.

Cisco has more than 200 offices worldwide. Addresses, phone numbers, and fax numbers are listed on the Cisco website at www.cisco.com/go/offices .

© 2016 Cisco Systems, Inc. All rights reserved.

ii

Preface

Audience

This guide is for the networking or computer technician responsible for installing Cisco IE 4010 series switches. We assume that you are familiar with the concepts and terminology of Ethernet and local area networking.

Purpose

This guide documents the hardware features of the Cisco IE 4010 switches. It describes the physical and performance characteristics of each switch, explains how to install a switch, and provides troubleshooting information.

This guide does not describe system messages that you might receive or how to configure your switch. For more information, see the Cisco IE4010 documentation at http://www.cisco.com/c/en/us/support/switches/industrial-ethernet-4010-series-switches/tsd-products-support-ser ies-home.html

For information about the standard Cisco IOS commands, see http://www.cisco.com/cisco/web/psa/configure.html?mode=prod&level0=268438303

Conventions

This document uses the following conventions and symbols for notes, cautions, and warnings.

Note:

Means reader take note. Notes contain helpful suggestions or references to materials not contained in this manual.

Caution: Means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data.

Warning: This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071

The safety warnings for this product are translated into several languages in the Cisco IE 4010 Switch Product Document

of Compliance that ships with the product. The EMC regulatory statements are also included in that guide.

Related Publications

Before installing, configuring, or upgrading the switch, see the release notes on Cisco.com for the latest information.

These documents provide complete information about the switch and are available on Cisco.com:

Regulatory Compliance and Safety Information for the Cisco IE 4010 Switch

Release Notes for the Cisco IE 4010 Switch

Cisco Systems, Inc.

www.cisco.com

iii

Obtaining Documentation, Obtaining Support, and Security Guidelines

Cisco IE 4010 Switch Software Configuration Guide

Device Manager Online help (available on the switch)

These compatibility matrix documents are available from this Cisco.com site: http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html

Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix (not orderable but available on Cisco.com)

Cisco Small Form-Factor Pluggable Modules Compatibility Matrix (not orderable but available on Cisco.com)

Obtaining Documentation, Obtaining Support, and Security

Guidelines

For information on obtaining documentation, obtaining support, providing documentation feedback, security guidelines, and also recommended aliases and general Cisco documents, see the monthly What’s New in Cisco Product

Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html

iv

Product Overview

The Cisco IE 4010 switch provides a rugged and secure switching infrastructure for harsh environments. It is suitable for industrial Ethernet applications, including process manufacturing, utility substations, intelligent transportation systems

(ITSs), rail transportation, and other similar deployments.

In industrial environments, you can connect the switch to any Ethernet-enabled industrial communication devices, including programmable logic controllers (PLCs), human-machine interfaces (HMIs), drives, sensors, and input and output (IO) devices.

In utility substations the switch can connect to devices such as Intelligent Electronic Devices (IEDs), distributed controllers, substation routers, Cisco IP Phones, Cisco Wireless Access Points, and other network devices such as redundant substation switches.

For detailed specifications, see the IE 4010 Data Sheet .

Switch Models, page 1

Cable Side, page 2

Power-Supply Side, page 10

Management Options, page 12

Switch Models

Table 1 Switch Models

Model

IE-4010-16S12P

Total

Ports

28

Uplinks

4 SFP

(100MB/

1G)

SFP Fiber

Ports

12

(100/1000

M)

Copper

10/100/1000

PoE/PoE+

Ports

1

12

(10/100/100

0M)

Default

Software

License

LAN

Base

2

Power Supplies

Support for 2 field-replaceable, redundant AC or DC power supplies.

IE-4010-4S24P 28 4 SFP

(100MB/

1G)

24

(10/100/100

0M)

LAN Base

For detailed specifications, see

Table 15 on page 72

.

Support for 2 field-replaceable, redundant AC or DC power supplies.

For detailed specifications, see the

Table 15 on page 72

.

1.

All copper Gigabit Ethernet interfaces support speed negotiation to 10/100/1000 mbps and duplex negotiation.Ethernet 4010 Series.

2.

Can be upgraded to IP Services at a fee. IP Services License Product Numbers are the following: L-IE4000-RTU= (Electronic SW

License for IE4000 Switches)

Cisco Systems, Inc.

www.cisco.com

1

Product Overview

Cable Side

Cable Side

Figure 1 Cisco IE-5000-16S12P Cable-Side View

1 LEDs

2 Express Setup button

3 Twelve 10/100/1000 PoE/PoE+ Ports (Downlinks) 8

6

7

4 Alarm port

5 USB (mini-Type B) console port

9

10

Power-input terminal

Flash memory card slot

Display mode button

Twelve 100/1000 SFP Ports

Console port

LEDs

For detailed information about LEDs see

LEDs, page 5

.

10/100/1000 PoE/PoE+ Ports (Downlinks)

You can set the 10/100/1000 ports on the switch to operate in any combination of half duplex, full duplex, or 10 or 100

Mb/s. You can set the ports for speed and duplex autonegotiation. The default setting is autonegotiate.

When set for autonegotiation, the switch determines the speed and duplex settings of the attached device and advertises its own capabilities. If the connected device also supports autonegotiation, the switch negotiates the best connection

(the fastest line speed that both devices support and full-duplex transmission if the attached device supports it) and configures itself accordingly. In all cases, the attached device must be within 328 feet (100 meters).

Warning: Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if interconnections are made using uninsulated exposed metal contacts, conductors, or terminals. Avoid using such interconnection methods, unless the exposed metal parts are located within a restricted access location and users and service people who are authorized within the restricted access location are made aware of the hazard. A restricted access area can be accessed only through the use of a special tool, lock and key or other means of security. Statement

1072

The 10/100/1000 PoE ports on the Cisco IE-4010 switches provide PoE support for devices that are compliant with IEEE

802.3af/802.3at. The Cisco prestandard PoE is also supported for Cisco IP Phones and Cisco Aironet Access Points. The

PoE ports on the switch deliver up to 30 W of PoE+ power. All twelve ports are PoE ports and can be assigned a port priority.

2

Product Overview

Cable Side

When both power-supply modules are installed, the system has enough power to support all twelve ports as PoE ports.

The maximum available PoE power is 200W.  

With one power module installed, the maximum available PoE power is 80W. In case one power-supply modules fails, the power to the low priority PoE ports is dropped, while power to the high priority PoE ports remains uninterrupted.

On a per-port basis, you control whether or not a port automatically provides power when an IP phone or an access point is connected.

The 10/100/1000 PoE ports use RJ-45 connectors with Ethernet pinouts. The maximum cable length is 328 feet (100 meters). The 100BASE-TX and 1000BASE-T traffic requires CA5, CAT5e, or CAT6 unshielded twisted pair (UTP) cable.

The 10BASE-T traffic can use CAT3 or CAT4 UTP cable.

For information about configuring and monitoring PoE ports, see the switch software configuration guide on Cisco.com.

For information about port connections and port specifications, see

Connecting Devices to the Ethernet Ports, page 30 .

Note:

The output of the PoE circuit has been evaluated as a Limited Power Source (LPS) per IEC 60950-1.

Alarm Ports

The switch has four alarm inputs and one alarm output.

Alarm Input

The alarm input is a dry-contact alarm port. You can connect up to four alarm inputs from devices, such as a door, a temperature gauge, or a fire alarm, to the alarm port. You can use the CLI to set the alarm severity to minor, or major. An alarm generates a system message and turns on an LED. See the

Alarm LEDs, page 9

for the LED descriptions.

Alarm Output

The alarm output can be configured as a major alarm. Output alarms often control an external alarm, such as a bell or a light. To connect an external alarm device to the relay, you connect two relay contact wires to complete the electrical

circuit. See for information on the alarm pinouts. see the Alarm Port, page 54

.

Mini USB Port

Note:

The 5-pin mini-Type B connectors resemble the 4-pin mini-Type B connectors. They are not compatible. Use only the 5-pin mini-Type B.

Figure 2 USB Mini-Type B Port

The configurable inactivity timeout reactivates the RJ-45 console port if the USB console port is activated, but no input activity occurs on it for a specified time period. When the USB console port deactivates due to a timeout, you can restore its operation by disconnecting and reconnecting the USB cable. For information on using the CLI to configure the USB console interface, see the switch software guide.

3

Product Overview

Cable Side

SD Flash Memory Card

The switch supports a flash memory card that makes it possible to replace a failed switch without reconfiguring the new switch. The slot for the flash memory card is on the front of the switch. The flash card is hot swappable and can be accessed on the front panel in non hazardous locations only. A cover protects the flash card and holds the card firmly in place. The cover is hinged and closed with a captive screw. This prevents the card from coming loose and protects against shock and vibration.

For more information on inserting and removing the flash memory card, see

Power-Supply Side, page 10 .

Display Mode Button

For detailed functionality see Display Mode Button, page 8 .

Power-Input Terminal

The power-input terminal provides screw terminals for the AC and DC power connections. The switch can operate with one or two power supplies. If one of the power sources fail, the other continues to power the switch. See

Power Supply

Installation, page 33 for information.

Figure 3 Power-Input Terminal

100/1000 SFP Ports

The switch Ethernet SFP modules provide connections to other devices. These field-replaceable transceiver modules provide the interfaces. The IE 4010 supports both FE and GE optics. SFP modules have local connectors (LCs) for fiber-optic connections or RJ-45 connectors for copper connections.

For the most up-to-date list of supported SFP models, see the IE 4010 Data Sheet .

For information about SFP modules, see your SFP module documentation and the Installing and Removing SFP Modules, page 26

. For more information about SFP/SFP+ modules and cables, see Transceiver Modules .

Console Ports

You can connect the switch to a PC running Microsoft Windows or to a terminal server through either the RJ-45 console port or the USB console port.

RJ-45 console port. The RJ-45 connection uses an RJ-45-to-DB-9 female cable.

USB mini-Type B console port (5-pin connector). The USB connection uses a USB Type A-to-5-pin mini-Type B cable.

4

Product Overview

Cable Side

The USB console interface speeds are the same as the RJ-45 console interface speeds.

To use the USB console port, you must install the Cisco Windows USB device driver on the device that is connected to

the USB console port (device running with Microsoft Windows). See Installing the Cisco Microsoft Windows XP, 2000,

Vista, 7, 8, and 10 USB Device Driver, page 64 for more information.

With the Cisco Windows USB device driver, connecting and disconnecting the USB cable from the console port does not affect Windows HyperTerminal operations. Mac OS X or Linux require no special drivers.

LEDs

You can use the switch system and port LEDs to monitor switch activity and performance.

5

Product Overview

Cable Side

Switch Panel LEDs

Figure 4 Switch LEDs (Cable Side)

6

7

4

5

1

2

3

Port Status LEDs 1-28

Express Setup button

SYS (system)

USB (mini-USB console)

SD (SD flash memory card)

Alarm Status (1 to 4 and Output).

PSU1 and 2 (power supply 1 and 2)

11

12

13

14

8

9

10

Port speed status

Port duplex status

Redundancy status

Synchronous Ethernet status

PoE

Display mode switch

SD card slot cover

Port LEDs

Each Ethernet port has a port LED. These port LEDs, display information about the individual ports. The port mode

determines the type of information shown by the port LEDs. Table 2 on page 7 lists the mode LEDs and their associated

port modes and meanings.

To select or change a mode, press the Mode button until the desired mode is highlighted. The Mode LED will turn ON solid green when a mode is selected and turn OFF when timeout (5 seconds) or a different mode is selected. When you

change port modes, the meanings of the port LED colors also change. Table 3 on page 7 explains how to interpret the

port LED colors in different port modes.

6

Product Overview

Cable Side

Table 2

Mode LED

All Off

SPEED

DUPLX

REDUN

SYNCE

PoE

Port Mode LEDs

Port Mode

Port status

Port speed

Port duplex mode

Redundancy status

Synchronous Ethernet status

PoE+ port power

Description

The port status. This is the default mode.

The port operating speed: 10, 100, 1000 mbps or 10 Gbps.

The port duplex mode: full duplex or half duplex.

Parallel Redundancy Protocol (PRP) status.

Not supported by software yet. Mode button skips this LED.

The PoE+ port status.

Table 3 Meaning of Switch LED Colors in Different Modes

Port Mode LED

All Off

Port LED Color

Off

Green

Blinking green

Alternating green-amber

Amber

Meaning

No link, or port was administratively shut down.

Link present, no activity.

Activity. Port is sending or receiving data.

Link fault. Error frames can affect connectivity, and errors such as excessive collisions, CRC errors, and alignment and jabber errors are monitored for a link-fault indication.

Port is blocked by Spanning Tree Protocol (STP) and is not forwarding data.

SPEED

DUPLX

(duplex)

REDUN

SYNCE

After a port is reconfigured, the port LED can be amber for up to 30 seconds as

STP checks the switch for possible loops.

10/100/1000/SFP ports

Downlink Ports

Off

Amber

Green

Port is not operating.

Port is operating at 10 Mb/s.

Port is operating at 100 Mb/s.

Port is operating at 1000 Mb/s.

Flashing green

Uplinks Ports

Green

Off

Port is operating at 1000 Mb/s.

Port is not operating.

Amber

Green

Port is operating in half duplex.

Port is operating in full duplex.

Green One or more redundancy protocols are configured and active (for example, HSR,

DLR, PRP, etc.)

One or more redundancy protocols are indicating a redundancy fault.

Blinking amber

Fast blinking green The port LEDs are showing ports that are participating in a redundancy protocol and the redundancy fault status of that port.

Off

7

Product Overview

Cable Side

Table 3 Meaning of Switch LED Colors in Different Modes (continued)

Port Mode LED

PoE/PoE+

Port LED Color

Off

Meaning

PoE/PoE+ is off.

Green

Alternating green and amber

Blinking amber

If the powered device is receiving power from an AC power source, the port LED is off even if the device is connected to the switch port.

PoE/PoE+ is on and all ports function correctly. The port LED is green when the switch port is providing power.

PoE/PoE+ is on but one of the low priority ports power is disconnected or failed.

Amber

PoE/PoE+ is on but one of the high priority ports power is disconnected or failed.

PoE+ faults occur when noncompliant cabling or powered devices are connected to a PoE+ port. Use only standard-compliant cabling to connect Cisco prestandard

IP Phones and wireless access points or IEEE 802.3af/at-compliant devices to

PoE+ ports. You must remove from the network any cable or device that causes a

PoE+ fault.

PoE/PoE+ is on with failures.

PoE+ is enabled by default.

Display Mode Button

The Display Mode Button allows you to choose the mode you want displayed by the port LEDs (items 1-3  in

Figure 4 on page 6 ). The LEDs with green text to the left of the Button indicate the chosen display mode. Each time you press the

switch, the mode indicator moves from SPEED, DUPLX, REDUN, SYNCE, and PoE respectively.

Power-Supply Module LEDs

The switch power-supply module LEDs are labeled PSU1 and PSU2 (on the switch) and PSU OK (on the power-supply module). They show whether power-supply modules 1 and 2 are receiving power.

Table 4 Power Supply Module LEDs

Color

Off

Green

Red

Blinking red

System Status

Power-supply module (1 or 2) is not installed.

Valid input is present, and the output is within the operating range.

Valid input is present, and the output is outside the operating range or is not present.

Power-supply module (1 or 2) is installed but valid input is not present.

8

Product Overview

Cable Side

Alarm LEDs

Table 5 Alarm LEDs

Color

1-4 Input Alarms

Green

Red

Blinking red

Output Alarm

Green

Red

System Status

Alarm not present

Minor alarm present

Major alarm present

Alarm not present

Alarm condition present

SD Flash Memory Card LED

Table 6 SD Flash Card LED

Color

Fast blinking amber

Slow blinking amber

Green

Blinking green

System Status

Unsupported SD flash memory card is detected.

SD flash memory card is not present.

SD flash memory card is functioning.

SD flash memory card transfer in progress.

USB LED

The USB LED indicates the console port is in use.

If you connect a cable to the console port, the switch automatically uses that port for console communication. If you connect two console cables, the USB console port has priority.

Table 7 USB LED

LED

USB console port

Color

Green

Off

Description

USB console port selected

RS232 Console selected

9

Product Overview

Power-Supply Side

System LED

Table 8 System LED

Color

Off

Blinking green

Green

Red

System Status

System is not powered on.

Power-On Self-Test (POST) is in progress.

System is operating normally.

System is receiving power but is not functioning properly.

Power-Supply Side

The power-supply side has the LED panel and two power-supply slots for the removable power supplies.

Figure 5 Switch with Both Power-Supply Modules

1 Power Supply slot 1

3 LED panel

1 2 3

2 Power Supply slot 2

10

Product Overview

Power-Supply Side

Power-Supply Side LEDs (Similar to

Figure 4Switch LEDs (Cable Side), page 6 )

Figure 6 Switch LEDs

1-28

SYS

USB

SD

Alarms

1-4 and

OUT

PSU 1-2

Port (Ethernet and SFP respectively)

Status LEDs

System Status

Mini-USB console port status

SD flash memory card status

Alarm ports and Alarm Output status

Power supply 1and 2 status

SPEED

DUPLX

REDUN

SYNCE

PoE

Port speed status

Port duplex status

Redundancy status

Synchronous Ethernet status

PoE

DISPLAY

MODE

Display Mode button

For more information about these LEDs, see

Switch Panel LEDs, page 6 .

Power Supply Features

The switch has two slots for power-supply modules:

PWR-RGD-LOW-DC-H: low-voltage DC

PWR-RGD-AC-DC-H: high-voltage AC or DC

Note:

For detailed specifications, see the IE 4010 Data Sheet .

11

Product Overview

Management Options

Caution: Only the -H version power supplies are certified safe for hazardous environments.

The switch supports these power-supply module combinations:

Single low-voltage DC

Single high-voltage AC or DC

Two high-voltage AC or DC

Two low-voltage DC

One high-voltage AC or DC and one low-voltage DC

For information on installing the power-supply modules, see

Power Supply Installation, page 33 .

See

Power-Supply Module LEDs, page 8 for information on the power supply LEDs.

Management Options

Cisco IOS CLI

You can configure and monitor the switch from the CLI. Connect your management station to the switch console port or use Telnet from a remote management station. See the switch command reference on Cisco.com for information.

SNMP network management

You can manage switches from a Simple Network Management Protocol (SNMP)-compatible management station.

The switch supports a comprehensive set of Management Information Base (MIB) extensions and four Remote

Monitoring (RMON) groups. See the switch software configuration guide on Cisco.com and the documentation that came with your SNMP application for information.

Device Manager

You can use Device Manager, which is in the switch memory, to manage individual and standalone switches. This web interface offers quick configuration and monitoring. You can access Device Manager from anywhere in your network through a web browser. For more information, see the Device Manager online help.

Prime Infrastructure

Cisco Prime Infrastructure simplifies the management of wireless and wired networks. It offers Day 0 and 1 provisioning, as well as Day N assurance from the branch to the data center. We call it One Management. With this single view and point of control, you can reap the benefits of One Management across both network and compute.

Network Configurations

See the switch software configuration guide on Cisco.com for an explanation of network configuration concepts. The software configuration guide also provides network configuration examples for creating dedicated network segments that are interconnected through Ethernet connections.

12

Switch Installation

Read the topics and perform the procedures in this order:

Warnings, page 13

Installation Guidelines, page 14

Verifying Switch Operation, page 14

Installing the Switch, page 15

Installing and Removing SFP Modules, page 26

Replacing the SD Flash Memory Card, page 30

Connecting Devices to the Ethernet Ports, page 31

Where to Go Next, page 32

Warnings

These warnings are translated into several languages in the Regulatory Compliance and Safety Information for the Cisco

IE 4010 Switch document.

These warning statements apply to all the switches:

Warning: Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. Statement 43

Warning: Read the installation instructions before you connect the system to its power source. Statement 1004

Warning: This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017

Warning: This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024

Warning: This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028

Warning: Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement

1030

Warning: Ultimate disposal of this product should be handled according to all national laws and regulations.

Statement 1040

Warning: For connections outside the building where the equipment is installed, the following ports must be connected through an approved network termination unit with integral circuit protection.

10/100/1000 Ethernet Statement 1044

Cisco Systems, Inc.

www.cisco.com

13

Switch Installation

Installation Guidelines

Warning: To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of:

140°F (60°C) Statement 1047

Note:

Operating temperatures exceeding 60C are not covered by the product safety certifications and approvals.

However, the switch can function in the installations under the environmental conditions listed

Switch Specifications, page 70

.

Warning: Installation of the equipment must comply with local and national electrical codes. Statement 1074

Note:

For U.S. installations, refer to national electrical code ANSI/NFPA 70.

Warning: To prevent airflow restriction, allow clearance around the ventilation openings to be at least:

1.75 in. (4.4 cm). Statement 1076

Warning: Avoid using or servicing any equipment that has outdoor connections during an electrical storm. There may be a risk of electric shock from lightning. Statement 1088

Installation Guidelines

Before installing the switch, verify that these guidelines are met:

Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting fixtures. Make sure that the cabling is away from other devices that might damage the cables.

Operating environment is within the ranges listed in

Technical Specifications, page 69 .

Relative humidity around the switch does not exceed 95 percent (non-condensing).

Altitude at the installation site is not higher than 13,800 feet.

For 10/100/1000 fixed ports, cable lengths from the switch to connected devices are not more than 328 feet (100 meters).

For more information about SFP/SFP+ modules and cables, see Transceiver Modules .

Airflow around the switch and through the vents is unrestricted. To prevent overheating, the switch must meet the minimum clearance of 1.75 inches (4.4 cm) at the top and bottom.

Note:

If the switch is installed in a closed or multirack assembly, the temperature around it might be greater than normal room temperature. Ensure that the internal temperature does not exceed the maximum ambient temperature specifications for the switch.

Verifying Switch Operation

Before installing the switch in a rack or on a wall, you should power the switch and verify that the switch passes the power-on self-test (POST).

To wire the switch to the power source, see

Power-Supply Module Installation, page 35 .

When the switch begins POST, the SYS LED blinks green, and the other LEDs stay green. When the switch passes POST, the SYS LED turns green. The other LEDs turn off and return to their operating status. If the switch fails POST, the SYS

LED is amber.

Note:

Contact Cisco Systems immediately if your switch fails POST.

After a successful POST, disconnect the power from the switch. For more information, see

Wiring the Power Source, page 39

. See the Installing the Switch, page 15

to install the switch in a rack or on a wall.

14

Switch Installation

Installing the Switch

Installing the Switch

Rack-Mounting, page 15

Wall-Mounting, page 22

Rack-Mounting

To rack-mount the switch, select the rack size and follow the steps in these sections:

Attaching Brackets for 19-Inch Racks, page 15

Attaching Brackets for 19-Inch Racks for IP-30 Compliance (Optional), page 17

Attaching Brackets for 23-Inch Racks, page 20

Attaching Brackets for ETSI Racks, page 21

Rack-Mounting the Switch, page 21

.

Warning: To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:

This unit should be mounted at the bottom of the rack if it is the only unit in the rack.

When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.

If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.

Statement 1006

Warning: For mounting railway-application equipment and for EN50155 standard compliance, the switch must be installed only in a rack mid-mounting position. If you install the switch in a front rack-mounting (cable side or power supply side) position or in a wall-mounting position, a mechanical failure can occur that results in the switch becoming detached from the rack. Statement 403

Attaching Brackets for 19-Inch Racks

The following illustrations show how to attach brackets to the switches.

15

Switch Installation

Installing the Switch

Figure 7 Attaching Brackets for 19-Inch Racks (Front bracket)

Figure 8 Attaching Brackets for 19-Inch Racks (Mid Mount)

16

Switch Installation

Installing the Switch

Figure 9 Attaching Brackets for 19-Inch Racks (Rear Mount)

Attaching Brackets for 19-Inch Racks for IP-30 Compliance (Optional)

Before installing the mounting brackets, you need to install the rubber plugs in the unused mounting holes.

Figure 10 on page 18 shows a close-up of the rubber plug. You can install the rubber plugs in the holes as shown in

Figure 11 on page 19 .

17

Switch Installation

Installing the Switch

Figure 10 Inserting the Rubber Plug

2

1

3

1 Rubber plug

2 Switch

3 Screwdriver

1.

Identify your bracket mounting position. See Attaching Brackets for 19-Inch Racks, page 15

.

2.

Insert the rubber plugs in the appropriate holes on both sides of the switch. See Figure 11 on page 19 .

3.

Use a screwdriver or pen to completely push in the rubber plugs. See

Figure 10 on page 18

.

4.

Install the brackets on both sides of the switch. See

Attaching Brackets for 19-Inch Racks, page 15

and Attaching

Brackets for 19-Inch Racks for IP-30 Compliance (Optional), page 17

.

18

Switch Installation

Installing the Switch

Figure 11 Plug locations by position

Note:

For IP-30 compliance: If you use 23-inch brackets or ETSI brackets, you can insert the rubber plugs in the same holes as shown in

Figure 11 on page 19

before installing the brackets.

19

Switch Installation

Installing the Switch

Attaching Brackets for 23-Inch Racks

If 23-inch brackets (RM-RGD-23IN=) are required, follow steps in Figure 12 on page 20

for installation.

Note:

23-inch and ETSI brackets should not be used in high vibration environments, including any railway application

(EN50155).

Note:

For IP-30 compliance: If you use 23-inch brackets or ETSI brackets, you can insert the rubber plugs in the same holes as shown in

Figure 11 on page 19 before installing the brackets.

Figure 12 Attaching 23-Inch Brackets

Note:

For IP-30 compliance: If you use 23-inch brackets, you can insert the rubber plugs in the same holes as shown in

Figure 11 on page 19 before installing the brackets.

20

Switch Installation

Installing the Switch

Attaching Brackets for ETSI Racks

Figure 13 Attaching Brackets (RM-RGD-ETSI=) for ETSI Racks

C isco CG S 25

20

2

1

1

2

3

1

3 Power-supply-side mounting position 1 Phillips flat-head screws

2 Cable-side-mounting position

Note:

23-inch and ETSI brackets should not be used in high vibration environments, including any railway application

(EN50155).

Note:

For IP-30 compliance: If you use ETSI brackets, you can insert the rubber plugs in the same holes as shown in

Figure 11 on page 19

before installing the brackets.

Rack-Mounting the Switch

After you attach the brackets on the switch, attach the brackets to the rack. See Figure 14 on page 22

.

21

Switch Installation

Installing the Switch

Figure 14 Rack-Mounting

After the switch is mounted in the rack:

1.

Wire the switch to a power source. See Wiring the Power Source, page 39 .

2.

Connect the ports. See Connecting Devices to the Ethernet Ports, page 31

.

3.

Attach the cable guide to prevent the cables from obscuring the LED panels on the devices in the rack. Use the supplied black screw to attach the cable guide to the left or right bracket.

For configuration instructions about the CLI setup program, go to

Configuring the Switch with the CLI Setup Program, page 57

.

Wall-Mounting

To wall-mount the switch, follow the steps in these sections:

Attaching Brackets, page 23

Attaching Brackets for IP-30 Compliance (Optional), page 24

Wall-Mounting the Switch, page 24

Warning: Read the wall-mounting instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system. Statement 378

Warning: For mounting railway-application equipment and for EN50155 standard compliance, the switch must be installed only in a rack mid-mounting position. If you install the switch in a front rack-mounting (cable side or power supply side) position or in a wall-mounting position, a mechanical failure can occur that results in the switch becoming detached from the rack. Statement 403

If the switch is wall-mounted in an enclosure, follow these minimum clearances:

Sides of switch (facing up and facing down): 3.75 in. (9.52 cm)

Port side 3.0 in. (7.62 cm)

Power supply side: 5.25 in. (13.33 cm)

Cover side (not facing wall): 1.75 in. (4.44 cm)

22

Switch Installation

Installing the Switch

Base side (facing wall): 0 in. (0 cm)

Attaching Brackets

Figure 15 Attaching 19-inch Rack Brackets

1

1 Phillips truss-head screws

23

Switch Installation

Installing the Switch

Attaching Brackets for IP-30 Compliance (Optional)

1.

Insert the rubber plugs in the appropriate holes on both sides of the switch. See Figure 10 on page 18 .

2.

Use a screwdriver or pen to completely push in the rubber plugs. See

Figure 10 on page 18

.

3.

Install the brackets on both sides of the switch. See

Attaching Brackets for 19-Inch Racks, page 15

.

Wall-Mounting the Switch

For the best support of the switch and cables, ensure that the switch is attached securely to wall studs or to a firmly attached plywood mounting backboard.

Orientation should exactly match the figure below, with power terminal down, the LEDs up, and the venting and Cisco

Logo facing away from the wall. See Figure 16 on page 25 and After the Switch is Mounted on the Wall, page 25

.

24

Switch Installation

Installing the Switch

Figure 16 Wall-Mounting

1

1 User-supplied screws

After the Switch is Mounted on the Wall

Wire the switch to a power source. See

Wiring the Power Source, page 39

.

For configuration instructions about using the CLI setup program, go to Configuring the Switch with the CLI Setup

Program, page 57

.

Connect the switch ports. See the Connecting Devices to the Ethernet Ports, page 31 .

25

Switch Installation

Installing and Removing SFP Modules

Installing and Removing SFP Modules

This section presents procedures to install and remove fiber-optic and 1000BASE-T SFP transceiver modules.

Installing SFP Modules

These sections describe how to install and remove SFP modules. SFP modules are inserted into SFP module slots on the front of the switch. Field-replaceable SFP modules provide the uplink interfaces, send (TX) and receive (RX).

You can use any combination of rugged SFP modules. Each SFP module must be of the same type as the SFP module on the other end of the cable, and the cable must not exceed the stipulated cable length for reliable communications.

For more information about SFP modules, see Cisco Transceiver Modules .

Caution: Depending on the SFP module you use, the operating temperature limits may be effected. Choose an SFP module appropriate to the installed environment.

Caution: To prevent electrostatic-discharge (ESD) damage, follow standard board and component handling procedures.

Warning: Do not insert and remove SFP modules while power is on; an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. Statement 1087

Note:

Removing and installing an SFP module can shorten its useful life. Do not remove and insert any module more often than is absolutely necessary.

Caution: Do not install or remove the LC SFP module with fiber-optic cables attached because of potential damage to the cables, the cable connector, or the optical interfaces in the SFP module. Disconnect all cables before removing or installing an SFP module.

Removing and installing an SFP module can shorten its useful life. Do not remove and insert SFP modules more often than is absolutely necessary.

Installing Fiber Optic SFP Modules

Warning: Class 1 laser product. Statement 1008

To install and cable an optical SFP transceiver uplink port:

1.

Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface.

2.

Find the send (TX) and receive (RX) markings on the module top.

On some SFP modules, the send and receive (TX and RX) markings might be replaced by arrows that show the direction of the connection, either send or receive (TX or RX).

3.

If the module has a bale-clasp latch, move it to the open, unlocked position.

4.

Align the module in front of the slot opening, and push until you feel the connector snap into place.

5.

If the module has a bale-clasp latch, close it.

6.

For fiber-optic SFP modules, remove the dust plugs and save.

7.

Connect the SFP cables.

26

Switch Installation

Installing and Removing SFP Modules

Figure 17 Installing an SFP Module

C isco IE 3010

Caution: Do not remove the dust plugs from the fiber-optic SFP module port or the rubber caps from the fiber-optic cable until you are ready to connect the cable. The plugs and caps protect the SFP module ports and cables from contamination and ambient light.

Installing 100/1000BASE-T SFP Modules

Table 9

Model Number

GLC-T

GLC-TE

100/1000BASE-T SFP Modules

Downlink Support

10/100/1000

10/100/1000

Uplink Support

10/100/1000

10/100/1000

The 100/1000BASE-T (copper) SFP transceiver, see

Figure 18 on page 28 , has a bale-clasp locking mechanism that

secures the transceiver in the module socket. The SFP network interface is an RJ-45 connector.

27

Switch Installation

Installing and Removing SFP Modules

Figure 18 1000BASE-T SFP Transceiver

1

2

3

1 RJ-45 connector

2 Bale-clasp latching mechanism in the closed (locked) position.

3 Bale-clasp latching mechanism in the open (unlocked) position.

Caution: To comply with GR-1089 intrabuilding lightning immunity requirements, you must use grounded, shielded, twisted-pair, CAT5 cabling.

Note:

When connecting to a 100/1000BASE-T-compatible server, workstation, or router, use four twisted-pair, straight-through CAT5 cabling for the SFP transceiver port. When connecting to a 100/1000BASE-T-compatible switch or repeater, use four twisted-pair, crossover CAT5 cabling.

To install a 100/1000BASE-T SFP transceiver:

1.

Attach an ESD-preventive wrist strap to your wrist and to the ESD ground connector on the chassis or to a properly grounded bare metal surface.

Caution: To avoid ESD damage, handle the SFP by its sides; do not touch the connector pins.

2.

Remove the SFP module from its protective packaging.

3.

Check the markings on the SFP transceiver to verify that you have the correct model for your network.

4.

Position the SFP transceiver in front of the port socket opening.

Note:

Different Cisco devices have different SFP transceiver socket configurations. Your Cisco device might require that the SFP transceiver be installed with the bale-clasp either in a latch-up or a latch-down orientation. Verify that you have the SFP transceiver oriented correctly when you position it in front of the port socket.

5.

With the bale-clasp closed (locked), slide the SFP transceiver into the socket until you feel it snap in place in the

socket. You may hear an audible click as the SFP transceiver latch engages in the socket ( Figure 17 on page 27 ).

6.

Connect the network interface cable RJ-45 plug to the SFP RJ-45 connector.

7.

Observe the port status LED:

Green indicates that the SFP transceiver and the target device established a link.

Amber indicates that the port is discovering the network topology and searching for loops. This process takes about 30 seconds, and then the LED turns green.

Off indicates that the target device might not be turned on, there might be a cable problem, or there might be

a problem with the adapter installed in the target device. Refer to Troubleshooting, page 45 for solutions to

cabling problems.

28

Switch Installation

Installing and Removing SFP Modules

Connecting to SFP Modules

This section describes how to connect to a fiber-optic or 1000BASE-T SFP port. For instructions on how to install or remove an SFP module, see

Connecting Devices to the Ethernet Ports, page 31

.

Warning: Class 1 laser product. Statement 1008

Warning: Do not connect or disconnect cables to the ports while power is applied to the switch or any device on the network because an electrical arc can occur. This could cause an explosion in hazardous location installations.

Be sure that power is removed from the switch and cannot be accidentally be turned on, or verify that the area is nonhazardous before proceeding. Statement 1070

Caution: Do not remove the rubber plugs from the SFP module port or the rubber caps from the fiber-optic cable until you are ready to connect the cable. The plugs and caps protect the SFP module ports and cables from contamination and ambient light.

Before connecting to the SFP module, be sure that you understand the port and cabling guidelines in

Installing and

Removing SFP Modules, page 26

. See Cable and Connectors, page 53

for information about the LC on the SFP module.

Caution: To prevent ESD damage, follow standard board and component handling procedures.

Connecting to a Fiber Optic SFP Module

To connect a fiber-optic cable to an SFP module:

1.

Remove the rubber plugs from the module port and fiber-optic cable, and store them for future use.

2.

Insert one end of the fiber-optic cable into the SFP module port.

3.

Insert the other cable end into a fiber-optic receptacle on a target device.

4.

Observe the port status LED:

The LED turns green when the switch and the target device have an established link.

The LED turns amber while the STP discovers the network topology and searches for loops. This process takes about 30 seconds, and then the port LED turns green.

If the LED is off, the target device might not be turned on, there might be a cable problem, or there might be a

problem with the adapter installed in the target device. See Troubleshooting, page 45 for solutions to cabling

problems.

5.

If necessary, reconfigure and restart the switch or the target device.

Connecting to a 1000BASE-T SFP Module

To connect a CAT5 cable to a 1000BASE-T SFP module:

Caution: To prevent ESD damage, follow standard board and component handling procedures.

1.

When connecting to servers, workstations, and routers, insert a four twisted-pair, straight-through cable in the

RJ-45 connector. When connecting to switches or repeaters, insert a four twisted-pair, crossover cable.

Note:

When connecting to a 1000BASE-T device, use a four twisted-pair CAT5 cable.

29

Switch Installation

Replacing the SD Flash Memory Card

2.

Insert the other cable end in an RJ-45 connector on a target device.

3.

Observe the port status LED.

The LED turns green when the switch and the target device have an established link.

The LED turns amber while the STP discovers the network topology and searches for loops. This process takes about 30 seconds, and then the port LED turns green.

If the LED is off, the target device might not be turned on, there might be a cable problem, or there might be problem with the adapter installed in the target device. See

Troubleshooting, page 45

for solutions to cabling problems.

4.

If necessary, reconfigure and restart the switch or target device.

Removing SFP Modules

1.

Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface.

2.

Disconnect the cable from the SFP module. For reattachment, note which cable connector plug is send (TX) and which is receive (RX).

3.

Insert a dust plug into the optical ports of the SFP module.

4.

If the module has a bale-clasp latch, pull the bale out and down to eject it. If the latch is obstructed and you cannot use your finger, use a small, flat-blade screwdriver or other long, narrow instrument.

5.

Grasp the SFP module, and carefully remove it from the slot.

6.

Place the module in an antistatic bag or other protective environment.

Figure 19 Removing a Bale-Clasp Latch SFP Module

1

1 Bale clasp

Replacing the SD Flash Memory Card

1.

Locate the flash memory card slot on the cable-side of the switch.

2.

Loosen the captive thumb screw. (Be careful not to cross-thread or over-tighten the thumb screw.)

30

Switch Installation

Connecting Devices to the Ethernet Ports

3.

Pull the cover open, and pull the cover tab from the hinge.

4.

Gently push the flash memory card to eject it. Place it in an anti-static bag to protect it from static discharge.

5.

Push the replacement card into the slot, and press it firmly in place. The card is keyed so that you cannot insert it the wrong way.

6.

Place the flash card slot cover tabs into the hinge.

7.

Close the cover, and hand-tighten the screw.

Connecting Devices to the Ethernet Ports

The Ethernet ports use standard RJ-45 connectors with Ethernet pinouts. The maximum cable length is 328 feet (100 meters). The 100BASE-TX and 1000BASE-T traffic requires Category 5, Category 5e, or Category 6 UTP cable. The

10BASE-T traffic uses Category 3 or Category 4 cable.

The autonegotiation feature is enabled by default on the switch. At this setting, the switch ports configure themselves to operate at the speed of the attached device. If the device does not support autonegotiation, you can set the switch port speed and duplex parameters. To maximize performance, either let the ports autonegotiate both speed and duplex, or set the port speed and duplex parameters on both ends of the connection.

For simplified cabling, the automatic medium-dependent interface crossover (auto-MDIX) feature is enabled by default.

With auto-MDIX enabled, the switch detects the required cable type for copper Ethernet connections and configures the interface accordingly. Therefore, you can use either a crossover or a straight-through cable for connections to a Ethernet port, regardless of the type of connected device.

See the switch software configuration guide or the switch command reference on Cisco.com for more information about autonegotiation and auto-MDIX.

If auto-MDIX is disabled, use the guidelines in

Cables and Adapters, page 55

to select the cable for connecting the

Ethernet ports to other devices.

When using PoE/PoE+, those ports have the same autonegotiation settings and cabling requirements as those in the

Connecting Devices to the Ethernet Ports, page 31 . These ports provide PoE power.

See Cable and Connectors, page 53

for information on the cables and connectors.

The ports provide PoE/PoE+ support for devices compliant with IEEE 802.3af/at and also provide Cisco prestandard

PoE/PoE+ support for Cisco IP Phones and Cisco Aironet Access Points.

On a per-port basis, you can control whether or not a port automatically provides power to a connected IP phone or an access point.

To access an advanced PoE planning tool, use the Cisco Power Calculator on Cisco.com: http://tools.cisco.com/cpc/launch.jsp

You can use this application to calculate the power supply requirements for a specific PoE/PoE+ configuration. The results show output current, output power, and heat dissipation.

Warning: Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if interconnections are made using uninsulated exposed metal contacts, conductors, or terminals. Avoid using such interconnection methods, unless the exposed metal parts are located within a restricted access location and users and service people who are authorized within the restricted access location are made aware of the hazard. A restricted access area can be accessed only through the use of a special tool, lock and key or other means of security. Statement

1072

31

Switch Installation

Where to Go Next

Caution: Category 5e and Category 6 cables can store high levels of static electricity. Always ground the cables to a suitable and safe earth ground before connecting them to the switch or other devices.

Where to Go Next

You can use the default configuration or use any of the management options described in the Management Options, page 12

to change the switch settings.

32

Power Supply Installation

This chapter describes how to remove and install a new or replacement power supply. Your switch ships with at least one installed power-supply module (AC or DC, depending on your order).

The power-supply modules are field-replaceable units (FRUs) and are hot-swappable when deployed in non-hazardous locations.

For translations of the safety warnings in this chapter, see the Regulatory Compliance and Safety Information for the

Cisco IE 4010 Switch on Cisco.com.

Power-Supply Modules, page 34

Installation Guidelines, page 35

Grounding the Switch, page 36

Installing the Power-Supply Module in the Switch, page 37

Wiring the Power Source, page 39

Removing the Power-Supply Module, page 44

Cisco Systems, Inc.

www.cisco.com

33

Power Supply Installation

Power-Supply Modules

Power-Supply Modules

Table 10 Power Supply Modules

Model

PWR-RGD-LOW-DC-H

PWR-RGD-AC-DC-H

Description

Low-voltage DC. For detailed specifications, see the IE 4010 Data Sheet

High-voltage AC or DC. For detailed specifications, see the

.

IE 4010 Data Sheet .

Figure 20 PWR-RGD-AC-DC-H Power-Supply Module

1

2

3

1

2

Power-supply module

PSU OK LED

Figure 21 PWR-RGD-LOW-DC-H Power-Supply Module

1

3 Captive screw

2

3

1

2

Power-supply module

PSU OK LED

3 Captive screw

Note:

Power Supplies with the -H suffix are required for hazardous environment installations. Non hazardous environments may use either -H or non -H supplies.

For a description of the PSU OK LEDs, see the

Power-Supply Module LEDs, page 8 .

34

Power Supply Installation

Power-Supply Module Installation

Power-Supply Module Installation

Installation Guidelines, page 35

Installing a Power-Supply Module, page 35

Wiring the Power Source, page 39

Removing the Power-Supply Module, page 44

Installation Guidelines

Observe these guidelines when removing or installing a power-supply module:

A power-supply module that is only partially connected to the switch disrupts the system operation.

Warning: Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place.

Statement 1029

Warning: Do not reach into a vacant slot while installing or removing a module. Exposed circuitry is an energy hazard. Statement 206

Warning: Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

Statement 1030

Warning: Avoid using or servicing any equipment that has outdoor connections during an electrical storm. There may be a risk of electric shock from lightning. Statement 1088

Installing a Power-Supply Module

This procedure is for installing a power-supply module in the PSU1 or PSU2 slot.

Warning: The covers are an integral part of the safety design of the product. Do not operate the unit without the covers installed. Statement 1077

Warning: This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028

Caution: Equipment installation must comply with local and national electrical codes.

Equipment That You Need

Torque driver(s) capable of 5 to 35 in-lbs

Ring, spade, or flanged spade terminal (terminals should be insulated)

Ring terminal (such as Tyco part number 2-34158-1 for 1614 AWG or 2-34852-1 for 1210 AWG wire)

Spade terminal (such as Tyco part number 54367-2 for 1614 AWG wire)

Flanged spade terminal (such as Tyco part number 2-324165-1 for 1614 AWG wire or 1-324581-1 for 1210

AWG wire)

Use the 16-14 AWG wire and appropriate terminals for the AC or high-voltage DC power supply

35

Power Supply Installation

Power-Supply Module Installation

Use the12-10 AWG wire and appropriate terminals for the low-voltage DC power supply

Crimping tool (such as Thomas & Bett part number WT2000, ERG-2001)

6-gauge copper ground wire

12-AWG wire (minimum) for the low-voltage power-supply module and 16-AWG (minimum) wire for the high-voltage power-supply module

For power source connections, use wires rated for at least 194°F (90°C).

UL- and CSA-rated style 1007 or 1569 twisted-pair copper wire

Wire-stripping tools for stripping 6-, 10-, 12-, 14-, and 16-gauge wires.

Number-2 Phillips screwdriver

Flat-blade screwdriver

Obtain these necessary tools and equipment:

Ratcheting torque screwdriver with a number-2 and a number-1 Phillips head that exerts up to 15 pound-force inches (lbf-in.) or 240 ounce-force inches (ozf-in.) of pressure.

Panduit crimping tool with optional controlled-cycle mechanism (model CT-720, CT-920, CT-920CH, CT-930, or

CT-940CH).

Wire-stripping tools.

12-gauge copper ground wire (insulated or noninsulated) when using the single-ground connection.

6-gauge copper ground wire (insulated or noninsulated) when using the dual-ground connection.

For the dual ground connection, also use the supplied dual-hole lug from the accessory kit.

Four leads of 16-gauge copper wire.

Grounding the Switch

Follow the grounding procedures at your site and observe these warnings:

Warning: This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024

Warning: When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046

Caution: Follow the grounding procedure instructions, and use an appropriately Listed or certified lug (included with the switch) for number-6 AWG wire and 10-32 ground-lug screws.

Note:

You can use the grounding lug to attach a wrist strap for ESD protection during servicing.

Follow these steps to install a dual-hole lug on the switch. Be sure to follow any grounding requirements at your site.

1.

Use a Phillips screwdriver or a ratcheting torque screwdriver with a Phillips head to remove the ground screw from the cable side of the switch. You need the screw in Step 4.

2.

Strip the 6-gauge ground wire to 0.5 inch (12.7 mm) ± 0.02 inch (0.5 mm). See

Figure 22 on page 37

. Stripping more than the recommended amount of wire can leave exposed wire from the connector.

36

Power Supply Installation

Power-Supply Module Installation

Figure 22 Stripping the Ground Wire

0.5 in. (12.7 mm) ± 0.02 in. (0.5 mm)

Wire lead

Insulation

3.

Insert the ground wire into the terminal lug, and crimp the terminal to the wire. (see Figure 23 on page 37

).

Figure 23 Crimping the Terminal Lug

4.

Slide the ground screw from Step 1 through the terminal lug. Insert the ground screws into the opening on the cable side.

Figure 24 Attaching the Terminal Lug

Cisco IE 3010

1 Dual-hole terminal lug

5.

Use a ratcheting torque screwdriver to tighten the ground screws to 30 in-lb (± 2 in-lb).

6.

Attach the other end of the ground wire to an appropriate ground.

Installing the Power-Supply Module in the Switch

1.

Ensure that the power is off at the AC or DC circuits.

37

Power Supply Installation

Power-Supply Module Installation

Locate the circuit breakers, turn them OFF, and lock out the circuit.

Warning: If the power is not off at the AC or DC circuit breaker, do not touch the power-input terminal.

2.

Use a Phillips screwdriver to loosen the two captive screws of the blank power-supply module and gently pull it out.

See

Figure 25 on page 38

and

Figure 26 on page 38

.

Figure 25 Loosen the Screws on the Power Supply Blank

C isco IE 3010

Sw itch Series

Figure 26 Remove the Power Supply Blank

C isco C onne cted G rid

Series

3.

Insert the power-supply module into the slot, and gently push it in. See Figure 27 on page 39 .

Note:

Ensure that the power supply module is flush with the switch.

Installing the DC Power Supply in the Switch

To remove and install a DC-powered power supply module, follow these steps:

1.

Turn off power at the DC circuits. To ensure that power is removed from the DC circuits, locate the circuit breakers for the DC circuits, switch the circuit breakers to the OFF position, and tape the circuit-breaker switches in the OFF position.

2.

Use a number-2 Phillips screwdriver to remove the plastic safety cover from the power supply terminal blocks.

3.

Use a number-1 Phillips screwdriver to remove the DC-input power wires from the power terminals.

Use a Phillips screwdriver to loosen the two captive screws at the lower edge that secure the power supply module to

the switch chassis ( Figure 27 on page 39

).

4.

Remove the power supply module from the power slot by pulling on the extraction handle.

5.

Insert the new power supply into the power supply slot, and gently apply pressure while pushing the module into the

slot ( Figure 27 on page 39 ). When correctly inserted, the power supply is flush with the switch rear panel.

38

Power Supply Installation

Power-Supply Module Installation

Figure 27 Insert the Power-Supply Module

6.

Use a ratcheting torque screwdriver to torque each screw to 8–10 in-lb.

Wiring the Power Source

Before you wire the power source, review these warnings:

Warning: This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than:

AC: 20 A, DC: 15 A Statement 1005

Warning: A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.

Statement 1022

Warning: Only trained and qualified personnel should be allowed to install or replace this equipment.

Statement 1030

Warning: Hazardous voltage or energy may be present on power terminals. Always replace cover when terminals are not in service. Be sure uninsulated conductors are not accessible when cover is in place. Statement 1086

1.

Ensure that the power is off at the AC or DC circuits.

Locate the circuit breakers, turn them OFF, and lock out the circuit.

Warning: If the power is not off at the AC or DC circuit breaker, do not touch the power-input terminal.

2.

Use a Phillips screwdriver to loosen the captive screw on the power-input terminal, and open the cover.

39

Power Supply Installation

Power-Supply Module Installation

Figure 28 Opening the Power-Input Terminal Cover

Cisco CGS 2520

100-240V

~, 50-60Hz, 2A

100-240V

~, 50-60Hz, 2A

5

2A

5

2A

10A

10A

The terminal screws labels are on the power-input terminal cover. See Figure 29 on page 41

.

40

Power Supply Installation

Power-Supply Module Installation

Figure 29 Power-Input Terminal

100-240V~, 50-60Hz, 2A

100-240V~, 50-60Hz, 2A

1

3

2

4

8

10

9

11

5

5 2A 5 2A

12

6

10A

7 13

10A

14

1 Line connection for high-voltage AC (PSU1)

2 Neutral connection for high-voltage AC (PSU1)

3 Positive connection for high-voltage DC (PSU1)

4 Negative connection for high-voltage DC (PSU1)

5 PSU1 (power-supply module 1)

6 Positive connection for low-voltage DC (PSU1)

7 Negative connection for low-voltage DC (PSU1)

8

9

Line connection for high-voltage AC (for PSU2)

Neutral connection for high-voltage AC (PSU2)

10 Positive connection for high-voltage DC (PSU2)

11 Negative connection for high-voltage DC (PSU2)

12 PSU2 (power-supply module 2)

13 Positive connection for low-voltage DC (PSU2)

14 Negative connection for low-voltage DC (PSU2)

Note:

The power-supply module 1 connection is labeled PSU1, and the power-supply module 2 connection is labeled

PSU2. Make sure that you connect the wires to the correct terminal screws.

3.

Use twisted-pair copper wire (12- to 18-AWG) to connect from the power-input terminal to the power source.

4.

Strip each of the two wires to 0.25 inch (6.3 mm) ± 0.02 inch (0.5 mm).

Note:

Do not strip more than 0.27 inch (6.8 mm) of insulation from the wire. Stripping more than the recommended amount of wire can leave exposed wire from the connector after installation.

Figure 30 Stripping the Input Power Source Wire

0.25 in. (6.3 mm) ± 0.02 in. (0.5 mm)

5.

Insert the wire into a spade terminal, and crimp it to the wire.

You can also use a ring or flanged spade terminal as listed in

Equipment That You Need, page 35 .

41

Power Supply Installation

Power-Supply Module Installation

Figure 31 Crimping the Spade Terminal Lug

6.

Loosen the terminal screw, and slide the terminal under the screw and washer. See

Figure 33 on page 43

.

Note:

Use the appropriate terminal screws based on power supply type: high-voltage (AC or DC) or low-voltage

(DC).

7.

Make the power connection:

AC Power Connection

Connect the line wire into the terminal screw labeled L and the neutral wire into the terminal screw labeled N to complete the AC connection.

Figure 32 Connecting the Wires to the High-Voltage AC Power (PSU1) z, 2.2A

100-240V~, 50-60H z, 2.2A

100-240V~, 50-60H

DC Power Connection

Connect the positive wire into the terminal screw labeled “+”, and the negative wire into the terminal screw labeled

”.

42

Power Supply Installation

Power-Supply Module Installation

Low-voltage DC Power-Supply Module

Connect the wires to the terminals labeled Lo.

High-voltage DC Power-Supply Module

Connect the wires to the terminals labeled Hi.

Note:

Ensure that you cannot see any wire lead. Only wire with insulation should extend from the terminal screw.

Figure 33 Connecting the Wires to the Low-Voltage DC Power (PSU2)

8.

Torque the captive screws (above the wires) to 8.5 in-lb (± 0.5 in-lb).

9.

Complete the power connection:

AC Power Connection

Connect the other end of the line wire (the one connected to L) to the line terminal on the AC-power source, and connect the other end of the neutral wire (the one connected to N) to the neutral terminal on the AC power source.

DC Power Connection

Connect the other end of the positive wire (the one connected to “+”) to the positive terminal on the DC-power source, and connect the other end of the negative wire (the one connected to “–”) to the negative terminal on the

DC power source.

Note:

Ensure that you cannot see any wire lead. Only wire with insulation should extend from the terminal screw.

If you have two power supplies, repeat steps 1 through 10.

10.

Close the power-input terminal cover.

11.

Use a ratcheting torque screwdriver to torque the screw to 7 in-lb (± 1 in-lb).

12.

Turn on the power at the AC or DC circuit.

13.

Verify that the PSU1 or PSU2 LED on the switch and PSU OK LED on the power-supply module are green.

See the switch software guide for information on how to configure the power supply settings.

43

Power Supply Installation

Removing the Power-Supply Module

Removing the Power-Supply Module

The power-supply modules are hot-swappable. By removing the power-supply modules, you can power off the switch without disconnecting the wiring from the power-input terminal.

1.

Ensure that the power is off at the AC or DC circuits.

Locate the circuit breakers, turn them OFF, and lock out the circuit.

Warning: If the power is not off at the AC or DC circuit breaker, do not touch the power-input terminal.

2.

Verify that the PSU LED and PSU OK LED is blinking red or is off.

3.

Use a Phillips screwdriver to loosen the captive screws that secure the power-supply module to the switch. See

Figure 34 on page 44 .

Warning: Hot surface. Statement 1079

Figure 34 Removing the Screws

C isco IE 3010

Sw itch Series

4.

Remove the power-supply module from the power slot. The power-supply module might be hot. See

Figure 35 on page 44

.

5.

Install a new power-supply module or a blank cover.

Figure 35 Removing the Power-Supply Module

C isco IE 3010

Sw itch Series

Caution: To prevent exposure to hazardous voltages and to contain electromagnetic interference (EMI), either a power-supply module or a blank cover must be in each power-supply module slot at all times.

44

Troubleshooting

This chapter provides these topics for troubleshooting problems:

Diagnosing Problems, page 45

How to Recover Passwords, page 48

Finding the Switch Serial Number, page 48

Diagnosing Problems

The switch LEDs provide troubleshooting information about the switch. They show boot errors, port-connectivity problems, and overall switch performance. You can also get statistics from Device Manager, the CLI, or an SNMP workstation.

Switch Boot Fast

Note:

Contact your Cisco TAC representative if your switch does not successfully boot.

Note:

You can disable boot fast and run POST by using the Cisco IOS CLI.

Switch LEDs

Look at the port LEDs information when troubleshooting the switch. See LEDs, page 5 for a description of the LED colors

and their meanings.

Switch Connections

Bad or Damaged Cable

Always examine the cable for marginal damage or failure. A cable might be just good enough to connect at the physical layer, but it could corrupt packets as a result of subtle damage to the wiring or connectors. You can identify this problem because the port has many packet errors or it constantly flaps (loses and regains link).

Exchange the copper or fiber-optic cable with a known good cable.

Look for broken or missing pins on cable connectors.

Rule out any bad patch panel connections or media converters between the source and the destination. If possible, bypass the patch panel, or eliminate media converters (fiber-optic-to-copper).

Try the cable in another port to see if the problem follows the cable.

Ethernet and Fiber-Optic Cables

Make sure that you have the correct cable:

Cisco Systems, Inc.

www.cisco.com

45

Troubleshooting

Diagnosing Problems

For Ethernet, use Category 3 or better copper cable for 10 Mb/s UTP connections. Use either Category 5, Category

5e, or Category 6 UTP for 10/100/1000 Mb/s, and PoE connections.

Verify that you have the correct fiber-optic cable for the distance and port type. Make sure that the connected device ports match and use the same type encoding, optical frequency, and fiber type.

Determine if a copper crossover cable was used when a straight-through was required or the reverse. Enable auto-MDIX on the switch, or replace the cable.

Link Status

Verify that both sides have a link. A broken wire or a shutdown port can cause one side to show a link even though the other side does not have a link.

A port LED that is on does not guarantee that the cable is functional. It might have encountered physical stress, causing it to function at a marginal level. If the port LED does not turn on:

Connect the cable from the switch to a known good device.

Make sure that both ends of the cable are connected to the correct ports.

Verify that both devices have power.

Verify that you are using the correct cable type. See Cable and Connectors, page 53

for information.

Look for loose connections. Sometimes a cable appears to be seated but is not. Disconnect the cable, and then reconnect it.

10/100/1000 Port Connections

If a port appears to malfunction:

Verify the status of all ports by checking the LEDs. For more information, see

Switch LEDs, page 45

.

Use the show interfaces command to see if the port is error-disabled, disabled, or shut down. Reenable the port if necessary.

Verify the cable type. See Cable and Connectors, page 53

.

SFP Module

Use only Cisco SFP modules. Each Cisco module has an internal serial EEPROM that is encoded with security information.

This encoding verifies that the module meets the requirements for the switch.

Inspect the SFP module. Exchange the suspect module with a known good module.

Verify that the module is supported on this platform. (The switch release notes on Cisco.com list the SFP modules that the switch supports.)

Use the show interfaces command to see if the port or module is error-disabled, disabled, or shutdown. Reenable the port if needed.

Make sure that all fiber-optic connections are clean and securely connected.

Interface Settings

Verify that the interface is not disabled or powered off. If an interface is manually shut down on either side of the link, it does not come up until you reenable the interface. Use the show interfaces command to see if the interface is error-disabled, disabled, or shut down on either side of the connection. If needed, reenable the interface.

46

Troubleshooting

Diagnosing Problems

Ping End Device

Ping from the directly connected switch first, and then work your way back port by port, interface by interface, trunk by trunk, until you find the source of the connectivity issue. Make sure that each switch can identify the end device MAC address in its Content-Addressable Memory (CAM) table.

Spanning Tree Loops

STP loops can cause serious performance issues that look like port or interface problems.

A unidirectional link can cause loops. It occurs when the traffic sent by the switch is received by the neighbor, but the traffic from the neighbor is not received by the switch. A broken cable, other cabling problems, or a port issue can cause this one-way communication.

You can enable UniDirectional Link Detection (UDLD) on the switch to help identify unidirectional link problems. For information about enabling UDLD on the switch, see the “Understanding UDLD” section in the switch software configuration guide on Cisco.com.

Switch Performance

Speed, Duplex, and Autonegotiation

Port statistics that show a large number of alignment errors, frame check sequence (FCS), or late-collisions errors, might mean a speed or duplex mismatch.

A common issue occurs when duplex and speed settings are mismatched between two switches, between a switch and a router, or between the switch and a workstation or server. Mismatches can happen when manually setting the speed and duplex or from autonegotiation issues between the two devices.

To maximize switch performance and to ensure a link, follow one of these guidelines when changing the duplex or the speed settings.

Let both ports autonegotiate both speed and duplex.

Manually set the speed and duplex parameters for the interfaces on both ends of the connection.

If a remote device does not autonegotiate, use the same duplex settings on the two ports. The speed parameter adjusts itself even if the connected port does not autonegotiate.

Autonegotiation and Network Interface Cards

Problems sometimes occur between the switch and third-party network interface cards (NICs). By default, the switch ports and interfaces autonegotiate. Laptops or other devices are commonly set to autonegotiate, yet sometimes issues occur.

To troubleshoot autonegotiation problems, try manually setting both sides of the connection. If this does not solve the problem, there could be a problem with the firmware or software on the NIC. You can resolve this by upgrading the NIC driver to the latest version.

Cabling Distance

If the port statistics show excessive FCS, late-collision, or alignment errors, verify that the cable distance from the switch

to the connected device meets the recommended guidelines. See the Cable and Connectors, page 53

.

47

Troubleshooting

Resetting the Switch

Resetting the Switch

These are reasons why you might want to reset the switch to the factory default settings:

You installed the switch in your network and cannot connect to it because you assigned the wrong IP address.

You want to reset the password on the switch.

Note:

Resetting the switch deletes the configuration and reboots the switch.

Caution: If you press the Express Setup button when you power on, the automatic boot sequence stops, and the switch enters bootloader mode.

To reset the switch:

1.

Press and hold the Express Setup button (recessed behind a small hole in the faceplate) for about 10 seconds with a paper clip or similar object. The switch reboots. The system LED turns green after the switch completes rebooting.

2.

Press the Express Setup button again for 3 seconds. A switch 10/100/1000 Ethernet port blinks green.

The switch now behaves like an unconfigured switch. You can configure the switch by using the CLI setup procedure described in

Configuring the Switch with the CLI Setup Program, page 57

How to Recover Passwords

Password recovery is a feature that a system administrator can enable or disable. If password recovery is disabled, the only way to recover from a lost or forgotten password is to clear the switch configuration entirely. For this procedure, see

the How to Recover Passwords, page 48

.

The Cisco IE 4010 Switch Software Configuration Guide provides details about enabling and disabling the password recovery feature and the procedure for recovering passwords.

Finding the Switch Serial Number

If you contact Cisco Technical Assistance, you need to know the serial number of your switch. The serial number is on the top of the switch. You can also use the show version command to obtain the switch serial number.

48

Hazardous Location Installation Information

This appendix provides hazardous location installation information for the Cisco IE 4010 Switchs.

Hazardous Area Installation Warnings

Caution: When installed in a Class I. Div/Zone 2 hazardous location environment, this equipment must be installed in a min. IP54, ATEX certified enclosure.

Caution: Airflow around the switch must be unrestricted. To prevent the switch from overheating, there must be the following minimum clearances:

- Top and bottom: 2.0 in. (50.8 mm)

- Sides: 2.0 in. (50.8 mm)

- Front: 2.0 in. (50.8 mm)

Contact your Cisco Technical Assistance Centre (TAC) if tighter spacings are required.

Caution: When installed in a Class I. Div/Zone 2 hazardous location environment. this equipment must be installed in a pollution degree 2 environment per IEC 60664-1)

Caution: This equipment is suitable for use in Class I. Division 2 . Groups A, B . C. D. or only nonhazardous locations.

Caution: Do not install or remove SFP modules when an explosive atmosphere may be present.

Caution: Do not install or remove power supplies when an explosive atmosphere may be present.

Caution: Do not use the USB Console Service Port when an explosive atmosphere may be present.

Warning: Exposure to some chemicals could degrade the sealing properties of materials used in the sealed relay device. Statement 381

Warning: This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017

Warning: To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of :

140°F (60°C) Statement 1047

Warning: When you connect or disconnect the power and/or alarm connector with power applied, an electrical arc can occur. This could cause an explosion in hazardous area installations. Be sure that all power is removed from the switch and any other circuits. Be sure that power cannot be accidentally turned on or verify that the area is nonhazardous before proceeding. Statement 1058

Warning: In switch installations in a hazardous location, the DC power source could be located away from the vicinity of the switch. Before performing any of the following procedures, locate the DC circuit to ensure that the power is removed and cannot be turned on accidentally, or verify that the area is nonhazardous before proceeding.

Statement 1059

Warning: This equipment is supplied as “open type” equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The interior of the enclosure must be accessible only by the use of a tool.

The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards. Statement 1063

Cisco Systems, Inc.

www.cisco.com

49

Hazardous Location Installation Information

Hazardous Area Installation Warnings

Warning: Use twisted-pair supply wires suitable for 86°F (30°C) above surrounding ambient temperature outside the enclosure. Statement 1067

Warning: When used in a Class I, Division 2, hazardous location, this equipment must be mounted in a suitable enclosure with a proper wiring method that complies with the governing electrical codes. Statement 1069

Warning: Explosion Hazard—The area must be known to be nonhazardous before installing, servicing, or replacing the unit. Statement 1082

Note:

This equipment has been tested by UL for the explosion, fire, shock and casualty hazards required by the applicable hazardous locations standards. UL certification does not cover the performance or reliability of any GPS hardware, GPS operating software, or other GPS-related aspects of equipment covered under this category.

Accordingly, UL makes no representations, warranties or certifications regarding the performance or reliability of any

GPS-related functions of equipment covered under this category.

North American Hazardous Location Approval

The following information applies when operating this equipment in hazardous locations:

English:

Français:

Products marked "Class I, Div 2, GP A, B, C, D" are suitable for use in Class I Division 2 Groups A,

B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest "T" number) may be used to help determine the overall temperature code of the system. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation.

Informations sur l'utilisation de cet équipement en environnements dangereux:

Les produits marqués "Class I, Div 2, GP A, B, C, D" ne conviennent qu'à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livré avec des marquages sur sa plaque d'identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut

être utilisé pour déterminer le code de température global du système. Les combinaisons d'équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l'installation.

EMC Environmental Conditions for Products Installed in the European Union

This section applies to products to be installed in the European Union.

The equipment is intended to operate under the following environmental conditions with respect to EMC:

A separate defined location under the user’s control.

Earthing and bonding shall meet the requirements of ETS 300 253 or CCITT K27.

AC-power distribution shall be one of the following types, where applicable: TN-S and TN-C as defined in IEC

364-3.

In addition, if equipment is operated in a domestic environment, interference could occur.

50

Hazardous Location Installation Information

Hazardous Locations Standards

Hazardous Locations Standards

The following standards were used for the hazardous locations approvals and certifications:

ANSI/ASA 12.12.01-2013

CAN/CSA C22.2 No. 60079-0-11 Ed. 2

CAN/CSA C22.2 No. 60079-15-12 Ed. 1

CSA C22.2 No. 213-M1987

EN 60079-0:2012+A11:2013

EN 60079-15:2010

IEC 60079-0 6th Edition

IEC 60079-15 4th Edition

UL 60079-0, 5th Ed, 2009-10-21

UL 60079-15, 3rd Ed, 2009-7-17

The following hazardous locations strings are provided on the access point:

Class 1, Div 2, Groups A B C D

Class 1, Zone 2, Ex nA nC IIC T4 Gc X

II 3 G, Ex nA nC IIC T4 Gc

Les normes suivantes ont été appliquées pour les approbations et les certifications dans le cadre d'environnements dangereux :

ANSI/ASA 12.12.01-2013

CAN/CSA C22.2 n° 60079-0-11 Éd. 2

CAN/CSA C22.2 n° 60079-15-12 Éd. 1

CSA C22.2 n° 213-M1987

EN 60079-0:2012+A11:2013

EN 60079-15:2010

IEC 60079-0, 6e édition

IEC 60079-15, 4e édition

UL 60079-0, 5e éd., 21-10-2009

UL 60079-15, 3e éd., 17-07-2009

Les marques d'homologation relatives aux environnements dangereux suivantes sont apposées sur le point d'accès :

Classe 1, Div 2, Groupes A B C D

Classe 1, Zone 2, Ex nA nC IIC T4 Gc X

II 3 G, Ex nA nC IIC T4 Gc

DEMKO 14 ATEX 1435X

Class 1, Zone 2, AEx nA nC IIC T4 Gc

DEMKO 14 ATEX 1435X

Classe 1, Zone 2, AEx nA nC IIC T4 Gc

51

Hazardous Location Installation Information

Hazardous Locations Standards

52

Cable and Connectors

Connector Specifications, page 53

Cables and Adapters, page 55

Connector Specifications

10/100/1000 Ports, page 53

SFP Module Connectors, page 53

Alarm Port, page 54

10/100/1000 Ports

The 10/100/1000 Ethernet ports on the switches use RJ-45 connectors. Figure 36 on page 53 shows the pinouts.

Figure 36 10/100/1000 Port Pinouts

Pin Label

7

8

5

6

3

4

1

2

TP0+

TP0-

TP1+

TP2+

TP2-

TP1-

TP3+

TP3-

Connector pins 1, 2, 3, and 6 are used for PoE.

1 2 3 4 5 6 7 8

SFP Module Connectors

Figure 37 on page 54

shows a LC style connector that is used with the SFP Module slots. It is a fiber-optic cable connector.

Cisco Systems, Inc.

www.cisco.com

53

Cable and Connectors

Connector Specifications

Figure 37 Fiber-Optic SFP Module LC Connector

Warning: Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Statement 1051

Console Port

The switch has two console ports: a USB 5-pin mini-Type B port (see Figure 38 on page 54

) and an RJ-45 (RS-232) console port.

Figure 38 USB Mini-Type B Port

The USB console port uses a USB Type A to 5-pin mini-Type B cable, shown in

Figure 39 on page 54

. The USB Type

A-to-USB mini-Type B cable is not supplied. You can order an accessory kit that contains this cable.

Note:

When running Linux, access the USB Console using Minicom instead of Screen.

Figure 39 USB Type A-to-USB 5-Pin Mini-Type B Cable

The RJ-45 console port uses an 8-pin RJ-45 connector . An RJ-45-to-DB-9 adapter cable is used to connect the console port of the switch to a console PC. You need to provide a RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a terminal. You can order a kit (part number ACS-DSBUASYN=) containing that adapter. For console port and adapter pinout information, see

Console Port, page 54

.

Alarm Port

The alarm port uses an RJ-45 connector. See

100/1000 SFP Ports, page 4

for more information. For information on alarm

ratings, see the Alarm Ratings, page 72

.

54

Cable and Connectors

Cables and Adapters

Figure 40 Alarm Port Details

Cables and Adapters

SFP Module Cables, page 55

Console Port Adapter Pinouts, page 55

SFP Module Cables

Each port must match the wave-length specifications on each end of the cable, and for reliable communications, the cable must not exceed the allowable length.

For more information about SFP/SFP+ modules and cables, see Transceiver Modules .

Console Port Adapter Pinouts

The console port uses an 8-pin RJ-45 connector. If you did not order a console cable, you need to provide an

RJ-45-to-DB-9 adapter cable to connect the switch console port to a PC console port. You need to provide an

RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a terminal. You can order an adapter (part number ACS-DSBUASYN=).

Table 11 on page 56

lists the pinouts for the console port, the RJ-45-to-DB-9 adapter cable, and the console device.

55

Cable and Connectors

Cables and Adapters

Table 11 Console Port Adapter Pinouts (RJ-45-to-DB-9)

Switch Console

Port (DTE)

Signal

RTS

DTR

TxD

GND

RxD

DSR

CTS

RJ-45-to-DB-9

Terminal Adapter

DB-9 Pin

8

6

2

5

3

4

7

Console

Device

Signal

CTS

DSR

RxD

GND

TxD

DTR

RTS

Note:

The RJ-45-to-DB-25 female DTE adapter is not supplied with the switch. You can order this adapter from Cisco

(part number ACS-DSBUASYN=).

Table 12 Console Port Adapter Pinouts (RJ-45-to-DB-25)

Switch

Console

Port (DTE)

Signal

RTS

DTR

TxD

GND

RxD

DSR

CTS

RJ-45-to-DB-25

Adapter

DB-25 Pin

5

6

3

7

2

20

4

Console

Device

Signal

CTS

DSR

RxD

GND

TxD

DTR

RTS

56

Configuring the Switch with the CLI Setup

Program

This appendix provides a command-line interface (CLI) setup procedure for a standalone switch. Before connecting the

switch to a power source, review the safety warnings in Warnings, page 13

and

Installation Guidelines, page 35

Accessing the CLI Through Express Setup

When you first set up the switch, you should use Express Setup to enter the initial IP information. This process enables the switch to connect to local routers and the Internet. You can then access the switch through the IP address for additional configuration.

Required Equipment

You need this equipment to set up the switch:

Computer with Windows 2000/Vista/2003/XP/Window7/Mac.

A Web browser (IE, Firefox) with JavaScript enabled.

A straight-through or crossover Category 5 Ethernet cable to connect your computer to the switch port.

Do not use the RS232 serial console port for express setup.

A small paper clip to reach to button.

Note:

Before running Express Setup, disable any pop-up blockers or proxy settings on your browser and any wireless client running on your computer.

Express Setup Procedure

To run Express Setup:

1.

Make sure that nothing is connected to the switch.

2.

Ensure the switch is in default factory mode.

Skip to next step if freshly out of the box.

a.

If not freshly out of the package, use a paper clip to reset the switch for 10 seconds until the SYS LED light turns red ; then release the paper clip.

Switch will automatically reboot once the SYS led goes red.

3.

Ensure no data port is connected to the switch.

Note

: During Express Setup, the switch acts as a DHCP server.

Cisco Systems, Inc.

www.cisco.com

57

Configuring the Switch with the CLI Setup Program

Accessing the CLI Through Express Setup

You can add a serial console cable to monitor the booting sequence. Do not hit [return key] on console screen.

Ensure the computer connected to switch is configured with DHCP.

4.

Web Browser: disable pop-up blockers and proxy settings.

5.

Connect power to the switch.

See the wiring instructions in Grounding the Switch, page 36

and

Wiring the Power Source, page 39

.

6.

Power on or reset the switch.

Use LEDs to monitor boot progress:

Sys blinking: bootloader

Sysl Blank: POST

Sys solid: exit post, IOS initializing

Sys and alarm LEDs green: IOS init done

~90 – 100 seconds after power on

EXP blinking: ready for express setup process

7.

Insert paper clip into express setup button (see Figure 4 on page 6 ) for 1-2 seconds.

When released, port Gig1/1 LED starts flashing green.

8.

Connect computer to port Gig1/1.

LED continues to blink.

9.

After computer has IP address (169.254.0.2), point browser to http://169.254.0.1.

10.

Leave the username blank and enter the default password, cisco.

Note:

The switch ignores text in the username field. The Express Setup window appears.

Troubleshooting: If the Express Setup window does not appear, make sure that any pop-up blockers or proxy settings on your browser are disabled and that any wireless client is disabled on your computer.

Note:

The screen capture below shows an IE 4000 series switch, but the functionality is identical for the IE 4010.

58

Configuring the Switch with the CLI Setup Program

Accessing the CLI Through Express Setup

11.

Enter all entries in English letters and Arabic numbers.

In the Network Settings (Required for Static IP):

IP Address: Enter a valid IP address for the switch.

You can later use the IP address to access the switch through Device Manager.

Switch Username and Password: Enter a password. The password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive, allows embedded spaces, but does not allow spaces at the beginning or end. In the Confirm Password field, enter the password again.

Note:

You must change the password from the default password, cisco.

Default Gateway: Enter the IP address of the router.

12.

Enter the Control Industrial Protocol (CIP) VLAN settings (optional):

CIP VLAN: Enter the VLAN on which CIP will be enabled. The CIP VLAN can be the same as the management

VLAN, or you can isolate CIP traffic on another VLAN that is already configured on the switch. The default CIP

VLAN is VLAN 1. Only one VLAN on a switch can have CIP enabled.

IP Address: Enter the IP address for the CIP VLAN. If the CIP VLAN is different from the management VLAN, you must specify an IP address for the CIP VLAN. Make sure that the IP address that you assign to the switch is not being used by another device in your network.

Subnet Mask: Select a mask from the drop-down list.

For more information about the CIP VLAN settings, click Help on the tool-bar.

13.

Optional Settings:

You can enter the optional information now, or enter it later by using Device Manager. For more information about the Express Setup fields, see the on-line help for the Express Setup window.

Click Submit to save your changes and to complete the initial setup.

59

Configuring the Switch with the CLI Setup Program

Accessing the CLI Through Express Setup

For more information about the optional settings, click Help on the tool-bar.

After you click Submit, these events occur:

The switch is configured and exits Express Setup mode.

The browser displays a warning message and tries to connect with the earlier switch IP address.

Typically, connectivity between the computer and the switch is lost because the configured switch IP address is in a different subnet from the IP address on the computer.

14.

Turn off DC power at the source, disconnect all cables to the switch, and install the switch in your network. See

Management Options, page 12 for information about configuring and managing the switch.

15.

If you changed the static IP address on your computer in Step 1, change it to the previously configured static IP address.

Note:

The screen capture below shows an IE 4000 series switch, but the functionality is identical for the IE 4010.

16.

You can now manage the switch by using the Cisco Network Assistant, Device Manager, or both. See

Management

Options, page 12 for information about configuring and managing the switch.

You can display Device Manager by following these steps:

a.

Start a web browser on your computer.

b.

Enter the switch IP address, username, and password in the web browser, and press Enter. The Device

Manager page appears.

Troubleshooting:

If the Device Manager page does not appear:

60

Configuring the Switch with the CLI Setup Program

Accessing the CLI Through the Console Port

Confirm that the port LED for the switch port connected to your network is green.

Confirm that the computer that you are using to access the switch has network connectivity by connecting it to a well known web server in your network. If there is no network connection, troubleshoot the network settings on the computer.

Make sure that the switch IP address in the browser is correct.

If the switch IP address in the browser is correct, the switch port LED is green, and the computer has network connectivity, continue troubleshooting by reconnecting the computer to the switch. Configure a static IP address on the computer that is in the same subnet as the switch IP address.

When the LED on the switch port connected to the computer is green, reenter the switch IP address in a web browser to display the Device Manager. When Device Manager appears, you can continue with the switch configuration.

Accessing the CLI Through the Console Port

You can enter Cisco IOS commands and parameters through the CLI. Use one of these options to access the CLI:

RJ-45 Console Port, page 61

USB Console Port, page 62

RJ-45 Console Port

1.

Connect the RJ-45-to-DB-9 adapter cable to the 9-pin serial port on the PC. Connect the other end of the cable to the switch console port.

2.

Start the terminal-emulation program on the PC or the terminal. The program, frequently a PC application such as

HyperTerminal or ProcommPlus, makes communication between the switch and your PC or terminal possible.

61

Configuring the Switch with the CLI Setup Program

Accessing the CLI Through the Console Port

Figure 41 Connecting the Console Cable

1

2

C isco IE 3010

1

1 RJ-45 console port 2 Console cable (RJ-45-to-DB-9 adapter cable)

3.

Configure the baud rate and character format of the PC or terminal to match the console port characteristics:

9600 baud

8 data bits

1 stop bit

No parity

None (flow control)

4.

Connect power to the switch as described in

Wiring the Power Source, page 39

.

5.

The PC or terminal displays the bootloader sequence. Press Enter to display the setup prompt. Follow the steps in

the Completing the Setup Program, page 65

.

USB Console Port

1.

If you are connecting the switch USB console port to a Windows-based PC for the first time, install a USB driver. See

Installing the Cisco Microsoft Windows XP, 2000, Vista, 7, 8, and 10 USB Device Driver, page 64

for more information.

62

Configuring the Switch with the CLI Setup Program

Accessing the CLI Through the Console Port

Figure 42 Connecting the USB Console Cable

1

2

C isco IE 3010

1

2

3

1

2

USB console port

USB cable

3 USB port on the PC

2.

Connect an USB cable to the PC USB port, and connect the other end of the cable to the switch mini-B

(5-pin-connector) USB console port. See

Figure 42 on page 63 .

3.

To identify the COM port assigned to the USB console port:

a.

Choose Start > Control Panel > Systems

b.

Click the Hardware tab and choose Device Manager.

c.

Expand the Ports section.

The assigned COM port appears in parenthesis at the end of the line with this entry: Cisco USB System Management

Console.

4.

Start the terminal-emulation program on the PC or the terminal.

The program, frequently a PC application such as HyperTerminal or ProcommPlus, makes communication possible between the switch and your PC or terminal.

5.

Configure the COM port.

6.

Configure the baud rate and character format of the PC or terminal to match the console port characteristics:

9600 baud

8 data bits

63

Configuring the Switch with the CLI Setup Program

Accessing the CLI Through the Console Port

1 stop bit

No parity

None (flow control)

7.

Connect power to the switch as described in

Wiring the Power Source, page 39

The PC or terminal displays the bootloader sequence.

8.

Press Enter to display the setup prompt.

9.

Follow the steps in the Completing the Setup Program, page 65 .

Installing the Cisco Microsoft Windows XP, 2000, Vista, 7, 8, and 10 USB Device

Driver

A USB device driver must be installed the first time a Microsoft Windows-based PC is connected to the USB console port on the switch. Use this procedure to install the USB driver on Windows XP, Windows 2000, Windows Vista,

Windows 7, Windows 8, and Windows 10.

1.

Obtain the file Cisco_usbconsole_driver_3_1.zip from the Cisco.com website https://software.cisco.com/download/release.html?mdfid=282979369&softwareid=282855122&release=3.1

The file details are as follows:

Description: Cisco_usbconsole_driver_3_1.zip

Release: 3.1

Release Date: 27/Nov/2014

File Name: Cisco_usbconsole_driver_3_1.zip

Size: 14.35 MB (15045453 bytes)

MD5 Checksum: eff2e955edcdc70209e6f9c8f6bd59cd

2.

Unzip the file and install the corresponding exe file.

3.

Navigate to the Device Manager window by performing a search in WIndows for Device Manager and opening it.

4.

Connect the USB cable from the Windows PC to the Cisco switch.

5.

From the Device Manager page, expand Ports (COM & LPT). Select USB Serial Port. Right-click and select Update

Driver Software ...

6.

In the Update Driver Software window, select Browse my computer for driver software. Then choose Let me pick

from a list of device drivers on my computer and click Next.

7.

Enable Show compatible hardware and choose Cisco Serial as the model. Click Next.

After the update is completed, Windows displays Windows has successfully updated your driver software.

8.

Click Close.

Uninstalling the Cisco Microsoft Windows XP, 2000, Vista, 7, 8, and 10 USB Driver

Note:

Disconnect the switch console terminal before uninstalling the driver.

1.

Run setup.exe for Windows 32-bit or setup(x64).exe for Windows-64bit.

64

Configuring the Switch with the CLI Setup Program

Entering the Initial Configuration Information

2.

Click Next.

3.

When the InstallShield Wizard for Cisco Virtual Com appears, click Next.

4.

When the Program Maintenance window appears, select the Remove radio button.

5.

Click Next.

6.

When the Remove the Program window appears, click Remove.

If a User Account Control warning appears, click Allow - I trust this program to proceed.

7.

When the InstallShield Wizard Completed window appears, click Finish.

Entering the Initial Configuration Information

To set up the switch, you need to complete the setup program, which runs automatically after the switch powers on. You must assign an IP address and other configuration information necessary for the switch to communicate with the local routers and the Internet.

IP Settings

You need this information:

Switch IP address

Subnet mask (IP netmask)

Default gateway (router)

Enable secret password

Enable password

Telnet password

Completing the Setup Program

Follow these steps to complete the setup program and to create an initial configuration for the switch:

1.

Enter Yes at these two prompts.

Would you like to enter the initial configuration dialog? [yes/no]: yes

At any point you may enter a question mark '?' for help.

Use ctrl-c to abort configuration dialog at any prompt.

Default settings are in square brackets '[]'.

Basic management setup configures only enough connectivity for management of the system, extended setup will ask you to configure each interface on the system.

Would you like to enter basic management setup? [yes/no]: yes

2.

Enter a host name for the switch, and press Return.

65

Configuring the Switch with the CLI Setup Program

Entering the Initial Configuration Information

On a command switch, the host name is limited to 28 characters and on a member switch to 31 characters. Do not use

-n, where n is a number, as the last character in a host name for any switch.

Enter host name [Switch]: host_name

3.

Enter an enable secret password, and press Return.

The password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive, allows spaces, but ignores leading spaces. The secret password is encrypted, and the enable password is in plain text.

Enter enable secret: secret_password

4.

Enter an enable password, and press Return.

Enter enable password: enable_password

5.

Enter a virtual terminal (Telnet) password, and press Return.

The password can be from 1 to 25 alphanumeric characters, is case sensitive, allows spaces, but ignores leading spaces.

Enter virtual terminal password: terminal-password

6.

(Optional) Configure Simple Network Management Protocol (SNMP) by responding to the prompts. You can also configure SNMP later through the CLI. To configure SNMP later, enter no.

Configure SNMP Network Management? [no]: no

7.

Enter the interface name (physical interface or VLAN name) of the interface that connects to the management network, and press Return. For this release, always use vlan1 as that interface.

Enter interface name used to connect to the management network from the above interface summary: vlan1

8.

Configure the interface by entering the switch IP address and subnet mask and pressing Return. The IP address and subnet masks shown below are examples.

Configuring interface vlan1:

Configure IP on this interface? [yes]: yes

IP address for this interface: 10.4.120.106

Subnet mask for this interface [255.0.0.0]: 255.0.0.0

9.

Enter Y to configure the switch as the cluster command switch. Enter N to configure it as a member switch or as a standalone switch.

If you enter N, you can configure the switch as a command switch later through the CLI. To configure it later, enter no.

Would you like to enable as a cluster command switch? [yes/no]: no

You have completed the initial configuration of the switch, and the switch displays its configuration. This is an example of the configuration output:

The following configuration command script was created: hostname switch1 enable secret 5 $1$Ulq8$DlA/OiaEbl90WcBPd9cOn1 enable password enable_password line vty 0 15 password terminal-password no snmp-server

!

no ip routing

!

interface Vlan1 no shutdown

66

Configuring the Switch with the CLI Setup Program

Entering the Initial Configuration Information ip address 10.4.120.106 255.0.0.0

!

interface FastEthernet1/0/1

!

interface FastEthernet1/0/2 interface FastEthernet1/0/3

!

...<output abbreviated> end

10.

These choices appear:

[0] Go to the IOS command prompt without saving this config.

[1] Return back to the setup without saving this config.

[2] Save this configuration to nvram and exit.

If you want to save the configuration and use it the next time the switch reboots, select option 2 to save it in NVRAM.

Enter your selection [2]:2

Make your selection, and press Return.

After you complete the setup program, the switch can run the default configuration that you created. To change this configuration or to perform other management tasks, enter commands at the

Switch>

prompt.

67

Configuring the Switch with the CLI Setup Program

Entering the Initial Configuration Information

68

Technical Specifications

Switch Specifications, page 70

Power-Supply Module Specifications, page 71

Alarm Ratings, page 72

Cisco Systems, Inc.

www.cisco.com

69

Technical Specifications

Switch Specifications

Switch Specifications

Table 13 Cisco IE 4010 Switch Specifications

Environmental Ranges

Operating temperature

1

-40°C to +74°C

-40°C to +75°C (Vented Enclosure Operating- 40 LFM Air Flow)

-40°C to +60°C (Sealed Enclosure Operating- 0 LFM Air Flow)

-34°C to +75°C (Fan or Blower equipped Enclosure Operating- 200

LFM Air Flow)

Storage temperature

Relative humidity

Operating altitude

Storage altitude

Thermal spacing

Operational shock

Non-Operational Shock

Physical Specifications

Weight

-40°C to +85°C (IEC 60068-2-2 Environmental Type Tested to

+85°C for 16 hours)

2

–40 to 185°F (–40 to 85°C)

5 to 95% (noncondensing)

Up to 13,800 ft (3049 m)

Up to 15,000 ft (4570 m)

1.75 in. (4.4 cm)

50G at 11ms, half sine and 200G ar 2.11ms, half sine.

65-80G at 9ms, Trapezoidal

Without power supply: IE-4010-4S24P; 12.1 lbs (5.46 kg,

IE-4010-16S12P: 12.7 lbs (5.78 kg)

PWR-RGD-AC-DC-H:2.55 lb (1.16 kg)

Dimensions (H x W x D)

PWR-RGD-LOW-DC-H:2.5 lb (1.13 kg)

1.75 x 17.5 x 15.0 in. (4.45 x 44.5 x 38.1 cm)

1.

Operating temperatures exceeding 60

°

C are not covered by the product safety certifications and approvals. However, the switch can function in the installations under the environmental conditions listed.

2.

The maximum operating temperature of the switch varies depending on the type of SFP module that you use.

70

Technical Specifications

Power-Supply Module Specifications

Table 14 Cisco IE 4010 Switch Power Requirements

Power Requirements

Nominal input voltage

Absolute maximum (short term) input voltage

PWR-RGD-AC-DC-H:

100 to 240 VAC, 50 to 60 Hz

100 to 250 VDC

PWR-RGD-LOW-DC-H:

24 to 60 VDC

PWR-RGD-AC-DC-H:

85 to 265 VAC, 47 to 63 Hz

88 to 300 VDC

Maximum PoE power available to Powered Devices (PD), with one power supply module installed

Maximum PoE power available to Powered Devices (PD), with two power supply modules installed

PWR-RGD-LOW-DC-H:

18 to 75 VDC

80W

200W

Table 15 Cisco IE 4010 Switch Power Consumption

FRU Configuration FRU Mode

Redundant

Max Power at 60C

IE-4010-4S24P

Watts BTU/hr

65 222

IE-4010-16S12P

Watts BTU/hr

70 239 IE-4010-4S24P with 2xDC power supplies, PoE not enabled

IE-4010-4S24P with 2xAC power supplies, PoE not enabled

IE-4010-4S24P with 1xDC power supply, PoE not enabled

IE-4010-4S24P with 1xAC power supply, PoE not enabled

IE-4010-4S24P with 2xDC power supplies, PoE enabled

IE-4010-4S24P with 2xAC power supplies, PoE enabled

Redundant

-NA-

-NA-

Load Shared

Load Shared

65

61

61

290

290

222

208

208

989

989

70

65

65

300

300

239

222

222

1024

1024

Power-Supply Module Specifications

71

Technical Specifications

Alarm Ratings

Table 16 Power Supply Module Specifications

Physical Specifications

Weight

PWR-RGD-AC-DC-H

PWR-RGD-LOW-DC-H

Dimensions (H x W x D)

PWR-RGD-AC-DC-H and PWR-RGD-LOW-DC-H

2.55 lb (1.15 kg)

2.5 lb (1.13 kg)

1.58 x 7 x 5 in. (4 x 17.8 x 12.7 cm) (without mounting flanges)

1.58 x 8.15 x 5 in. (4 x 20.7 x 12.7 cm) (with mounting flanges)

Alarm Ratings

Table 17 Alarm Input and Output Ratings

Alarm Ratings

Alarm input electrical specification

Alarm output electrical specification

No external voltage needed to activate alarm inputs. The open circuit voltage between any Alarm input (1 to 4) and Alarm input Common is 5VDC and the loop current is 2 mA max per input.

30VDC @ 1A, 48VDC @ 0.5A

72

advertisement

Key Features

  • Rugged design for harsh environments
  • PoE/PoE+ support for powering devices
  • Redundant power supply options
  • Secure switching infrastructure
  • SFP uplink ports for fiber connectivity

Frequently Answers and Questions

What are the key features offered by these network switches?
The Cisco IE 4010 series switches offer several key features, including rugged design for harsh environments, PoE/PoE+ support for powering devices, redundant power supply options, secure switching infrastructure, and SFP uplink ports for fiber connectivity.
How many ports does each switch model have?
The IE 4010-16S12P model has 28 ports, while the IE 4010-4S24P model has 28 ports.
What are the supported power supply options?
The switches support various power supply combinations including single low-voltage DC, single high-voltage AC or DC, two high-voltage AC or DC, two low-voltage DC, and one high-voltage AC or DC and one low-voltage DC.
What are the management options available for these switches?
The switches offer multiple management options, including Cisco IOS CLI, SNMP network management, Device Manager web interface, and Prime Infrastructure.

Related manuals

Download PDF

advertisement

Table of contents