Haier 2U14CS1ERA Service manual
Haier 2U14CS1ERA is a wall-mounted DC Inverter air conditioner that offers efficient cooling and heating performance. It features a sleek and compact design that seamlessly blends with any décor, making it an ideal choice for residential and commercial spaces. With its advanced inverter technology, this air conditioner delivers precise temperature control, ensuring maximum comfort while minimizing energy consumption.
PDF
Download
Document
Advertisement
Advertisement
SERVICE MANUAL Order No.AC1012S002V0 Wall mounted Type DC Inverter EK-Series Model No. 2U14CS1ERA AS07GS2ERA AS09GS2ERA AS12GS2ERA AS07GS2ERA AS09GS2ERA AS12GS2ERA indoor unit and remote controller 2U14CS1ERAoutdoor unit WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death © (Qingdao Haier Air Conditioner General corp.,Ltd) All right reserved .Unauthorized copying and distribution is a violation of law Haier Group 2U14CS1ERA-SM 9 14 of indoor unit 14 5.2 main function and control specification of outdoor unit 22 5.3 29 41 41 41 52 68 83 9.1 Removal of Air Filter 83 9.2 Removal of Front panel 85 9.3 Horiaontal Flap 87 9.4 Drain pan 88 9.5 Vertical Blades and Swing Motor 89 9.6 90 9.7 91 9.8 93 2U14CS2ERA-SM 9.9 Removal of Outdoor panel ............................................................................95 9.10 Removal of Electrical Box ...........................................................................99 9.11 Removal of Fan and Fan Motor .................................................................100 9.12 Removal of Fan motor bracket and partition ..............................................102 9.13 Removal of Compressor and Heat Exhange ..........................................104 107 107 108 110 11 Description of Coding rules of Unit Model......................................................112 2U14CS1ERA-SM Introduction 1. Introduction 1.1 Safety Cautions Be sure to read the following safety cautions before conducting repair work. The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead to serious accidents under some conditions if they are not followed. Therefore, be sure to observe all the safety caution items described below. About the pictograms This symbol indicates an item for which caution must be exercised. The pictogram shows the item to which attention must be paid. This symbol indicates a prohibited action. The prohibited item or action is shown inside or near the symbol. This symbol indicates an action that must be taken, or an instruction. The instruction is shown inside or near the symbol. After the repair work is complete, be sure to conduct a test operation to ensure that the equipment operates normally, and explain the cautions for operating the product to the customer. 1.1.1 Caution in Repair Warning Be sure to disconnect the power cable plug from the plug socket before disassembling the equipment for a repair. Working on the equipment that is connected to a power supply can cause an electrical shook. If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits, do not touch any electrically charged sections of the equipment. If the refrigerant gas discharges during the repair work, do not touch the discharging refrigerant gas.The refrigerant gas can cause frostbite. When disconnecting the suction or discharge pipe of the compressor at the welded section, release the refrigerant gas completely at a well-ventilated place first. If there is a gas remaining inside the compressor, the refrigerant gas or refrigerating machine oil discharges when the pipe is disconnected, and it can cause injury. If the refrigerant gas leaks during the repair work, ventilate the area. The refrigerant gas can generate toxic gases when it contacts flames. The step-up capacitor supplies high-voltage electricity to the electrical components of the outdoor unit. Be sure to discharge the capacitor completely before conducting repair work.A charged capacitor can cause an electrical shock. Do not start or stop the air conditioner operation by plugging or unplugging the power cable plug. Plugging or unplugging the power cable plug to operate the equipment can cause an electrical shock or fire. 1 Domestic Air Conditioner 2U14CS1ERA-SM Introduction Warning Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock. Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid electrical shocks. Be sure to turn off the power switch and unplug the power cable when cleaning the equipment. The internal fan rotates at a high speed, and cause injury. Do not tilt the unit when removing it. The water inside the unit can spill and wet the furniture and floor. Be sure to check that the refrigerating cycle section has cooled down sufficiently before conducting repair work. Working on the unit when the refrigerating cycle section is hot can cause burns. Use the welder in a well-ventilated place. Using the welder in an enclosed room can cause oxygen deficiency. 1.1.2 Cautions Regarding Products after Repair Warning Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to conduct repair work. Never attempt to modify the equipment. The use of inappropriate parts or tools can cause an electrical shock, excessive heat generation or fire. When relocating the equipment, make sure that the new installation site has sufficient strength to withstand the weight of the equipment. If the installation site does not have sufficient strength and if the installation work is not conducted securely, the equipment can fall and cause injury. Be sure to install the product correctly by using the provided standard installation frame. For Incorrect use of the installation frame and improper installation can cause the equipment to fall, resulting in injury. integral units only Be sure to install the product securely in the installation frame mounted on a window frame. If the unit is not securely mounted, it can fall and cause injury. For integral units only 2 Domestic Air Conditioner 2U14CS1ERA-SM 9.9 Removal of Outdoor panel ............................................................................95 9.10 Removal of Electrical Box ...........................................................................99 9.11 Removal of Fan and Fan Motor .................................................................100 9.12 Removal of Fan motor bracket and partition ..............................................102 9.13 Removal of Compressor and Heat Exhange ..........................................104 107 107 108 110 11 Description of Coding rules of Unit Model......................................................112 Introduction 2U14CS1ERA-SM Caution Installation of a leakage breaker is necessary in some cases depending on the conditions of the installation site, to prevent electrical shocks. Do not install the equipment in a place where there is a possibility of combustible gas leaks. If a combustible gas leaks and remains around the unit, it can cause a fire. Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not installed properly, water can enter the room and wet the furniture and floor. For integral units only 1.1.3 Inspection after Repair Warning Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet all the way. If the plug has dust or loose connection, it can cause an electrical shock or fire. If the power cable and lead wires have scratches or deteriorated, be sure to replace them. Damaged cable and wires can cause an electrical shock, excessive heat generation or fire. Warning Do not use a joined power cable or extension cable, or share the same power outlet with other electrical appliances, since it can cause an electrical shock, excessive heat generation or fire. 4 Domestic Air Conditioner Introduction 2U14CS1ERA-SM Caution Check to see if the parts and wires are mounted and connected properly, and if the connections at the soldered or crimped terminals are secure. Improper installation and connections can cause excessive heat generation, fire or an electrical shock. If the installation platform or frame has corroded, replace it. Corroded installation platform or frame can cause the unit to fall, resulting in injury. Check the grounding, and repair it if the equipment is not properly grounded. Improper grounding can cause an electrical shock. Be sure to measure the insulation resistance after the repair, and make sure that the resistance is 1 M ohm or higher. Faulty insulation can cause an electrical shock. Be sure to check the drainage of the indoor unit after the repair. Faulty drainage can cause the water to enter the room and wet the furniture and floor. 5 Domestic Air Conditioner 2U14CS1ERA-SM Functions Category Healthy negative ion make your room full of an abundance natural negative ions. AS07/09/12GS2ERA 2U14CS1ERA N Child lock Avoid the child's wrong operation on the remote controller Y 3D air flow The 3D airflow is able to deliver the airflow horizontally and vertically. N 24Hour timer Use the timer function to set on,or off,or from on to off,or from off to on Y Easy clean design The panel is easy to wash and the airflow vents can be detached easily Y With twin-blade technology ,the airflow can be adjusted not to blow directly Y Catches most small particles and remove unpleasant odors effectively. Y Sleep mode The setting temprature and the indoor noise can be adjusted to a more comfortable level when you set the "sleep mode"during night sleep Y 4 Fan setting Slect the fan speed LO,MED,HI,AUTO Y adjust the last fixed operation mode automatically. Y Quick cooling or heating Y lower noise operation condition Y Intelligent air Anti-mold filter Auto mode Power mode Soft mode Constant temperature Make dehumidifying in the room while keeping the constant temperature inside dehumidification Note: Y: Holding Functions N : No Functions N 2U14CS1ERA-SM 3 Specification 2U14CS1ERA (9+12)K 4.2(1.2~5.8) 4.6(1.5~5.0) 14300(4100~19800) 15700(5100~17050) 3612(1032~4988) 3956(1290~4300) 2.8 4.9 5.0 1070(290~1400) 1090(335~1650) 95 95 3.93 4.22 9.52 30(double)20(single) 15 20 20 7.5/8.0(7K/9K) 8.3/8.8(12K) 6.6/7.2(7K/9K) 7.2/7.8(12K) 6.1/6.6(12K) 5.7/6.4(7K/9K) - 4 0.15 0.15 33 33 265×795×187 360X871X304 8.8. 11.3 38/34/30(7K/9K) 48 7 39/36/32(12K) 49 2U14CS1ERA-SM 2U14CS1ERA DA108X1C-20FZ3 855 ESTER OIL VG74 0.48 R410a 1.2 35 35 1236 1236 40 4.9 5.0 1070 1090 6 540x780x270 612X905X375 38 41 5 51 51 61 61 2U14CS1ERA-SM Connector wiring diagram 3ULQWHG&LUFXLW%RDUG&RQQHFWRU:LULQJ'LDJUDP 4.1᧶Indoor unit Connectors Connectors PCB(1) 1) CN26 Connector for fan motor 2) CN1 Connector for heat exchanger thermistor and Room temperature thermistor 3) CN11 Connector for UP&DOWN STEP motor 4) CON2 Connector for power N wire 5) CON1 Connector for power L 6) CN32 Connector for display board 7) C0N6,C0N8 Connector for ions generator 8) CON7 Connector for communicate between the indoor board and the outdoor board 9) CN27 Connector for fan motor’s PG back. 10) CN34 Connector for long-range control 11) CN20 Connector for room card Note: Other designations PCB(1) (INdoor Control PCB) 1) SW1 Connector for Forced operation ON / OFF switch 2) SW2 1 Select remote code A or B,2 Select 25 or 35 ,3 Select room card able or disable 3) SW4 Select 20 or other,if select 20,SW2 must select 25(ON) 4) RV1 Varistor 5) FUSE1 Fuse 3.15A/250VAC 9 Domestic Air Conditioner Connector wiring diagram 2U14CS1ERA-SM PCB(1) CN26 CN1 CN27 SW1 CN11 CN32 CN20 CON1 CON2 CON6 CN34 CON8 CON7 10 Domestic Air Conditioner 2U14CS1ERA-SM 4.2 Connector wiring diagram ᧶outdoor unit Connectors PCB(1) (Control PCB) 1) CN1,CN2 Connector for power N and L 2) CN3ǃCN8 Connector for ground 3) CN23 Connector for DC POWER 15Vand 5V to the module board 4) CN9,CN10 Connector for CN9,CN8 on the module board 5) CN22 Connector for fan motor 6) CN11 Connector for four way valve coil 7) CN17,CN18,CN19,CN20,CN21ǃCN47 Connector for thermistors 8) CN24 Connector for communicate between the control board and the module board 9) CN28,CN25 Connector to P and N of the module board 10) CN36 Connector for communicate between indoor and outdoor unit 11) CN15ǃCN16 Connector for electric expansion valves PCB(2) (module PCB) CN10 Connector for the DC power 5V and 15V form the control PCB CN11 Connector for communicate between the control board and the module board P( CN1), N(CN5) Connector for CN28,CN25 on the control board LO (CN6),LI(CN7) Connector for reactor AC_L(CN8),AC_N(CN9) Connector for CN10,CN9 on the control board CN2(U), CN3(V), CN4(W) connector for the compressor Note: Other Designations PCB(1) (Control PCB) 1) FUSE 1, Fuse (25A,250VAC) 2)LED 1 keep light representative normal ,if keep flash interval representative trouble Alarm 3)RV1,RV2,RV3 Varistor 11 Domestic Air Conditioner Connector wiring diagram 2U14CS1ERA-SM CN9 CN10 CN36 CN8 CN3 CN2 CN49 CN11 CN1 CN15 CN45 CN16 CN47 CN17 CN18 CN19 CN20 CN21 CN23 CN24 CN25 CN28 PCB(1) 12 Domestic Air Conditioner Connector wiring diagram 2U14CS1ERA-SM CN6 CN8 CN9 CN7 CN10 CN11 CN4 CN3 CN2 CN1 CN5 PCB(2) 13 Domestic Air Conditioner 2U14CS1ERA-SM Functions and control 5.Funcitions and Control 5.1 Main functions and control specification of indoor unit 5.1.1 Automatic operation When the system is under the automatic operation option, the appropriate operation mode will be decided according to the differences between the preset temperature and the indoor temperature after the system starts up. Then, the system will operate according to the chosen mode. In the following conditions, Tr stands for indoor temperature and Ts stands for outdoor temperature. The system will choose the operation mode according to the following conditions when entering into the automatic operation option for the first time. TrıTs-3ć Choose the cooling mode Tr˘Ts-3ć Choose the warming mode Under the automatic option, the system will switch between the cooling and warming modes according to the change of the indoor temperature. If the air conditionic is under the cooling mode, when the preset temperature for stopping the compressor is reached, the compressor will be stopped. The indoor temperature will be tested again 15 minutes after the stop of the compressor. At the moment, if the tested temperature is under the Tr˘Ts-3ć condition, the system will be switched into the warming mode. If not, the system will remain in the cooling mode. If the air conditionic is under the warming mode, when the preset temperature for stopping the compressor is reached, the compressor will be stopped. The indoor temperature will be tested again 15 minutes after the stop of the compressor. At the moment, if the tested temperature is under the Tr˚Ts+3ć condition, the system will be switched into the cooling mode. If not, the system will remain in the warming mode. 5.1.2 Cooling operation mode Temperature control range: 16ć---30ć Temperature difference: r1ć * Control features: When Tr˄input airflow˅>Ts˄set temperature˅ć, the compressor will be opened,the indoor fan will operate at the set speed and the mode signal will be sent to the outdoor system. When Tr˄input airflow˅ Ts˄set temperature˅ć, the compressor will be opened,the indoor fan will operate at the set speed and the mode signal will be sent to the outdoor system. The system will keep the original status if Tr= Ts. Airflow speed control: (temperature difference 1ć) Automatic: When Tr>=Ts+3ć, high speed. When Ts+1ć=<Tr<Ts+3ć, medium speed When Tr<Ts+1ć, low speed When the sensor is off, low speed When the airflow speed has no delay from the high to low switching, the speed should be delayed for 3 minutes (remain at high speed for 3 minutes.) before the next switch. 14 Domestic Air Conditioner 2U14CS1ERA-SM Functions and control Manus: When the system is operating, you can set the high, medium or low speed manually. ( When the sensor is on or off, the system will change the speed 2 seconds after receiving the signal.) *Airgate location control: the location for the airgate can be set according to your needs. *Defrosting function: preventing the frosting on the indoor heat exchanger (when cooling or demoisture). When the compressor works continuously for 1/6 minutes (adaptable in EEPROM) and the temperature of the indoor coils has been below zero centigrade for 10 seconds, the compressor will be stopped and the malfunction will be recorded in the malfunction list. The indoor system will continue to run. When the temperature of the indoor coil is raised to 7ć, the compressor will be restarted again (the prerequirement of 3 minutes’ delay should be satisfied.) * timing system on/off function. * Dormant control function. 5.1.3 Demoisture mode. * temperature control range: 16---30ć * temperature difference: r1ć Control feature: send the demoisture signal to the outdoor system. When Tr>Ts+2ć, the compressor will be turned on, the indoor fan will operate at the set speed. When Tr is between the Ts and Ts+2ć, the outdoor system will operate at the high demoisture frequency for 10 minutes and then at the low demoisture mode for six minutes. The indoor fan will operate at low speed. When Tr< Ts, the outsystem will be stopped, the indoor fan will be stopped for 3 minutes and then turned to the low speed option. All the frequency converses have a f1ć difference. * Wind speed control: Automatic: When Tr >= Ts+ 5ć, high speed. When Ts+3ćdTr< Ts+5ć, medium speed. When Ts+2ćdTr< Ts+3ć, low speed. When Tr<Ts+2ć, light speed. If the outdoor fan stopped, the indoor fan will be paused for 3 minutes. If the outdoor fan stopped for more than 3 minutes and the outdoor system still operates, the system will be changed into light speed mode. When the airflow speed has no delay from the high to low switching, the speed should be delayed for 3 minutes (remain at high speed for 3 minutes.) before the next switch. Manual: When the sensor is off or Tr< Ts+3ć, the manual operation can not be made. (obligatory automatic operation.) *Airgate location control: the location for the airgate can be set according to your needs. *Defrosting function: preventing the frosting on the indoor heat exchanger (when cooling or demoisture). When the compressor works continuously for 1/6 minutes (adaptable in EEPROM) and the temperature of the indoor coils has been below zero centigrade for 10 seconds, the compressor will be stopped and the malfunction will be recorded in the malfunction list. The indoor system will continue to run. When the temperature of the indoor coil is raised to 7ć, the compressor will be restarted again (the prerequirement of 3 minutes’ delay should be satisfied.) * coil protection (synchronic overheating protection) are installed for the four directions latch malfunctions when demoisturing. 15 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM * timing system on/off function. * Dormant control function. 5.1.4 Heating operation mode. * temperature control range: 16---30ć * temperature difference: r1ć * control feature: the temperature compensation is automatically added and the system will send the heating signals to the outdoor system. If TrdTs, the outdoor compressor is turned on, the indoor fan will be at the cold air proof mode. If Tr>Ts+3, the outdoor system is turned off, the indoor fan will be at the heat residue sending mode. If Tr<Ts+3ˈthe outdoor system will be turned on again, the indoor fan will be at the cold air proof mode. *Indoor fan control manual control: You can choose high, medium, low and automatic speed control. Automatic: When Tr<Ts, high speed. When Ts=<Tr=<Ts+2ć, medium speed. When Tr> Ts+2ć, low speed. When the airflow speed has no delay from the high to low switching, the speed should be delayed for 3 minutes (remain at high speed for 3 minutes.) before the next switch. *Airgate location control: the location for the airgate can be set according to your needs. Coldair proof operation 1. The indoor operation is as the following diagram, the air speed can be raised only after the speed has reached a certain level. 2.. In the cold air proof operation, the fan won’t stop after the start up. 3. During the cold air proof operation, the indoor system will continuously send ‘indoor high speed’ signals to the outdoor system. * Residue heat sending. The indoor fan will send the residue heat at a low speed for 12 seconds. If other conditions are satisified, when the compressor stops, the indoor system will operate at a light speed. The indoor fan will stop when the coil temperature is below 23e. 5.1.5 strength operation 16 Domestic Air Conditioner 2U14CS1ERA-SM Functions and control a. the system enters the mode after receiving the ‘strength signal’. Send strength operation signal to the outdoor system. The mode change finishes the strength operation. Entering ‘mute’, you can have normal operation or signal control such as timing to finish the strength operation. When the system is at the automatic option with the strength/ mute function, if the system enters the cooling mode, the cooling strength/ mute function will be offered; if the system enters the heating mode, then the heating strength/ mute function will be offered; if the system enters the airflow mode, there will be no strength/ mute function. 5.1.6 Mute operation the system enters the mode after receiving the ‘mute signal’. a. Mute heating: the airflow speed is slight, the system sends the mute signal to the outdoor system. b. mute cooling: the airflow speed is slight, the system sends the mute signal to the outdoor system. When the compressor operates, the airflow speed is mute speed. EEPROM is adaptable. Mute operation can not work under the demoisturing and airflow-sending operation. 5.1.7 Air refreshing After receiving the signal from the remote control,(HV series: the background light of the ‘health’ logo is green. HS series: the ‘health’indicator will be lighted). If the fan operates, the negative ion generator operates to realize the negative sending function. If the indoor fan stops, the negative ion generator is turned off. When the negative ion generator is turned off, if the air refreshing system is turned on, the negative ion generator will be turned on when the fan operates. 5.1.8 Timing. You can set 24 hours’ on/off timing accordingly. After the setting, the timing indicator will be lightened. Also, the light will be turning off after the timing is finished. The followings are several timing methods. 1.system /on timing: The timing indicator will be lightened and the indoor system is under the waiting mode. The light will be turned off when the timing is finished and the rest of the system will operate under a normal condition. The timing starts since the last reception of the timing singal. You can have the dormacy setting under the timing mode, the order of your settings will be operated according to the timing settings. 2.system /off timing: When the system is turned on, the timing indicator is lightened, the rest of the system will operated under a normal condition. When set time comes, the indicator light will be turned off and the system will be turned off. If you have set the dormant functions, the order of your settings will be operated according to the timing settings. 3 system /on and off timing: The settings will be completed according to the orders. 17 Domestic Air Conditioner 2U14CS1ERA-SM 5.1.9 Functions and control Dormant operation The dormant timing is an eight hours unadaptable one. The timing signs are shown on the V series board. (RC series show the dormant signal, the timing light is lighted on the 6 lights board). 2.1 Under the cooling/ demoisture operation, after the setting of the dormant operation, the set temperature will be raised for 1 centigrade after 1 hour’s operation and will be raised for 1 centigrade 1 hour later. The system will keep this status for 6 hours and then close. 2.2 Under the heating mode, after the setting of the dormant operation, the et temperature will fall 2 centigrades after 1 hour’s operation and will fall 2 centigrades 1 hours later. 3 hours after the preceding operations, the set temperature will be raised for 1 centigrade and the system will keep this status for 3 hours and then close down. 2.3 During the dormant time, except the change of the system mode or a new press on the dormant setting keys, the timing of the 8 hours dormancy will take the first timing as the start time, any presses on other keys will not affect the original timing. 2.4 Indoor fan control under the dormant operation. If the indoor fan is at the high speed before the dormant operation setting, the speed will be turned to medium after the setting. If the fan is at the medium speed before the dormant setting, the speed will be turned to low after the setting. If the fan is at the low speed before the dormant setting, the speed will not change. 18 Domestic Air Conditioner 2U14CS1ERA-SM Functions and control 5.1.10 Urgent on/off input Press the urgency button the buzzer will ring. The system will enter the automatic mode if you don’t press the button for more than 5 seconds. Under the system off mode, if you press the urgency key for 5 to 10 seconds, the system will start the test operation. Under the system off mode, If you press the urgency key for 10 to 15 seconds, the display screen will show the resume of the last malfunction. If the system is under operation, the press on the urgency key will stop it. Under the system off mode, the display screen will show automatic running sign. Under the system off mode, the system will not receive the remote control signal if the press on the urgency key doesn’t last for 15 seconds or if the key is loosened. Urgency operation: If you press the urgency key for less than 5 seconds, the buzzer will ring when you press the on/off key. The system will enter the urgency operation when the urgency key is loosened. The urgency operation is fully automatic. Test operation. The inlet temperature sensor doesn’t work, the indoor fan and the indoor air direction board motor works synchronically. High speed airflow, cooling, outdoor system on, etc, will send the ambient temperature 30 centigrade and coil temperature 16 centigrade information to the outdoor system. Test operation The defrost protection of the evaporator doesn’t work. The temperature control doesn’t work. The test operation will be finished in 30 minutes. The test operation can be stopped by the relative commands from the remote control. 5.1.11 Low load protection control In order to prevent the frosting of the indoor heat interaction device, the outdoor system will be stopped if the indoor heat interaction temperature is below zero centigrade for 5 minutes, but the fan will continue to operate. The outdoor system will be started again when the heat interaction temperature is above 7 centigrade and the system has been stopped for 3 minutes. The malfunction will be stored in the malfunction resume and will not be revealed. 5.1.12 High load protection control The outdoor system will be stopped if the coil temperature is above 65ć for 2 minutes. The indoor fan will be controlled by the thermostat. The outdoor system can be restarted when the coil temperature is below 42ć and the system has been stopped for 3 minutes. The malfunction will be stored in the malfunction resume and will not be revealed. 19 Domestic Air Conditioner 2U14CS1ERA-SM Functions and control 5.1.13 abnormal operation of indoor system When the outdoor system operates, if the indoor system operation differs from the outdoor system, the abnormal operation malfunction will be reported. 10s after the report, the indoor system will be closed. Outdoor system mode Indoor system mode conflicts cooling heating yes cooling cooling no cooling airflow no heating heating no heating airflow yes heating cooling yes 5.1.14 Malfunction list resume. Nothing is presented if there is no code list. The malfunction display will automatically finish in 10 seconds. The remote control only receives the sigals for stop. According to the signals, the malfunction resume presentation finishes. The resume restores after the power supply restores. 5.1.15 abnormality confirmation approaches. 1 indoor temperature sensor abnormality: under the operation, the normal temperature ranges from 120 degree to -30 degree. When the temperature goes beyond this range, the abnormality can be confirmed. If the temperature goes back into the range, the system will automatically resume. 2 indoor heat interaction sensor abnormality: under the operation, the normal temperature ranges from 120 degree to -30 degree. When the temperature goes beyond this range, the abnormality can be confirmed. If the temperature goes back into the range, the system will automatically resume. 3 indoor malfunction: Out door malfunction: When the indoor system receives the outdoor malfunction codes, it will store the code into E2 for the malfunction list resume. The indoor system will continue to operate according to the original status, the malfunction code will not be revealed or processed. 4 transmission abnormality: If the indoor system can’t receive the outdoor system for 8 minutes, the communication abnormality can be confirmed and reported and the outdoor system will be stopped. 5.1.16 Single indoor system operation * Enter condition: First, set the high speed airflow and 30 centigrade set temperature, then press the dormant keys for 6 times within 7 seconds, the system will feedback with 6 rings. * After the system enters the separate indoor system operation mode, the indoor system will 20 Domestic Air Conditioner 2U14CS1ERA-SM Functions and control operate according to the set mode and neglect the communication signals of the outdoor system. However, it has to send signals to the outdoor system. * Quitting condition: This mode can be quitted after receiving the quitting signal from the remote control or urgency system. The indoor system thus can quit the single operation mode. 5.1.17 Power cut compensation. * Entering condition: Press dormant button 10 times within 7 second, the buzzer will ring 4 times and the present system status will be stored into the EEPROM of the indoor system. * After entering the power cut compensation mode, the processing of the indoor system should be as the followings: Remote control urgency singal: operate according to the remote control and the urgent conditions, the present status will be stored into the EEPROM of the indoor system. * Quitting conditions: Press dormant button 10 times within 7 seconds and the buzzer will ring twice. 5.1.18 Fixed frequency operation. 1. Fixed cooling: a. under G code condition: high speed cooling, set 16ć, press temperature ‘-‘ key and the set key at the same time. The system will enter the fixed frequency operation after the buzzer rings twice. b. The proceeding programs are as the follows: Entering the fixed frequency operation, you can set the fixed strength location 1 and send the coolng signal to the outdoor system. Meanwhile, you can fix the indoor system at high speed mode, the location of the airflow directin board can be switched to the maximal position. c. Quitting condition: The fixed frequency cooling can be quitted after receiving the remote signal, and the system will enter the remote setting status. 2. Fixed heating: a. under G code condition: high speed heating, set 30ć, press temperature ‘+‘ key and the set key at the same time. The system will enter the fixed frequency operation after the buzzer rings twice. b. The proceeding programs are as the follows: Entering the fixed frequency operation, you can set the fixed strength location 1 and send the heating signal to the outdoor system. Meanwhile, you can fix the indoor system at high speed mode, the location of the airflow directin board can be switched to the maximal position. c. Quitting condition: The fixed frequency heating can be quitted after receiving the remote signal, and the system will enter the remote setting status. 5.1.19 Test program First, connect the test program terminal on the mainboard, then connect the system to the power circuit. The test program will operate as follows. HV series display: The buzzer rings for one time—the signal will be sent to outdoor system for 0.5 second— the violet is sent for 0.5-- the background light turns to white—the back ground light turns to white—the background light turns to white—the background light is fully lighted for 0.5 21 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM second—LCD screen lights for 0.5 second— the step-in motor fully output for 0.5 second—then the motor doesn’t output for 0.5 second—the motor fully output again for 0.5 second. The test program finishes. 5.1.20 Time cutting function: connect the test program terminal on the mainboard after connecting the system to the power circuit. The CPU of the main control will be 60 times faster. 5.1.21 Display function When the system starts up, the background and the LCD will be fully lighted for 3 seconds. The background colour is white. 5.1.21.1 Three-color background The multi-color indicator is not lighted when the system is off. The mode-switching will change the indicator colors. Red color is for heating mode, blue for cooling, water color for demoisturing, white for automatic mode, pink for airflow sending, green for health mode and yellow green for air refreshing. The colors health, refreshing colors are preferred to the mode colors. If different status exist at the same time, then the last set color will be shown. The lighting key of the control board can turn on or off the display. 5.2 The control system of outdoor unit 5.2.1˖The operation frequency of outdoor unit and its control 5.2.1.1˖The operation frequency control of compressor The operation frequency scope of compressor˖ Mode Minimun operation frequency Maximun operation frequency Heating 34Hz 96Hz Refrigeration 34 Hz 72Hz 5.2.1.2˖The starting of compressor When the compressor is started for the first time, it must be kept under the conditions of 34Hz,56Hz,82Hz for one minute (the overheating protection of the outdoor unit air-blowing temperature, immediately decrease the frequency when the compressor is overflowing and releasing the pressure)ˈthen it can be operated towards the target frequency. When the machine runs normally, there’s no such process. After starting the compressor for operation, the compressor should run according to the calculated frequency, and every determined frequency for protection should be prior to the calculated frequency. 5.2.1.3˖The speeds of increasing or decreasing the frequency of the compressor The speed of increasing or decreasing the frequency rapidly 1 -----------1HZ/second The speed of increasing or decreasing the frequency slowly 2 -----------1HZ/10seconds 22 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM 5.2.1.4˖The calculation of the compressor’s frequency 1˅ǃThe minimum/maximum frequency limitation A ˊ While refrigerating: ˢ ˉ ˩ ˝ ˴ ˉ ̎ is the maximum operation frequency of the compressor; ˢˉ˩INˉ̎ is the minimum operation frequency of the compressor. BˊWhile heating: ˢˉ˩˝˴ˉ̀ is the maximum operation frequency of the compressor; ˢˉ˩INˉ̀is the minimum operation frequency of the compressor. 1˅ǃThe frequency limitation which is affected by the environment temperature. Heating mode: Serial No. Temperature scope Frequency limitation 1 Wh_c<-12 Max_hz8 96 HZ 2 Wh_c<-8 Max_hz7 96 HZ 3 Wh_c<-2 Max_h z4 96 HZ 4 Wh_c<5 Max_hz5 96 HZ 5 5<Twh̰12 Max_hz1 85HZ 6 12<Twh̰18 Max_hz2 56 HZ 7 18<Twh Max_hz6 44HZ Remarks: the above are the maximum frequency limitations of the complete appliance which are affected by the environment, and they have nothing to do with the ability of the indoor unit. 23 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM Refrigeration/dehumidification mode:: Serial No. Temperature scope Frequency limitation 1 Twh̰16 Max_hz1 34HZ 2 16<Twh̰24 Max_hz2 40 HZ 3 24<Twh̰32 Max_hz3 62 HZ 4 32<Twh̰44 Max_hz4 68 HZ 5 Twh>44 Max_hz5 40 HZ Remarks: the above are not only the maximum frequency limitations of the complete appliance which are affected by the environment, but also the maximum ability limitation of the system. When the starting ability is not the maximum, its maximum frequency limitation is calculated by the following equations: The frequency limitation which is affected by the temperature and under the condition of actual ability˙the actural running system ability*the maximum frequency which is limited by the temperature and under the condition of maximum ability/the maximum designing ability of the system T=ě˄Ti*Pi˅/ěPi (Ti=|Tst_i-Tnh_i the indoor environment temperature| ;Pi˙i the ability of the indoor unit) Refrigeration/dehumidification: T <1 ˙1 ˙2 ˙3 >=4 50% 70% 100% 120% 140% T <1 ˙1 ˙2 ˙3 >=4 The percentage of the rated frequency P 50% 70% 100% 130% 180% The percentage of the rated frequency P Heating mode˖ K=ěKi/the number of running machines The indoor set airflow speed Breeze Low Medium High Strong Quiet Healthy airflow The percentage of the rated frequency Ki 70ˁ 80% 90% 100% 120% 70% 70% The calculation of the actual output frequency: when there is no healthy airflow: F =F-ED-*hPhK When the healthy airflow has been set: F =F-ED-*hPhK˄airflow speed˅hK˄healthy airflow˅ When refrigerating, it is needed to satisfy ˢˉ˩INˉ̀< F<ˢˉ˩˝˴ˉ̀ When heating, it is needed to satisfy ˢˉ˩INˉr< F<ˢˉ˩˝˴ˉr 5.2.2˖The outdoor fan control (exchange fan) When the fan is changed among every airflow speed (including stop blowing), in order to avoid the airflow speed from skipping frequently, it must be kept under each mode for over 30 seconds, and then it can be changed to another mode (when refrigerating, the time is changed to 15 24 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM seconds). 5.2.2.1˖ The outdoor fan control when refrigerating or dehumidifying After the compressor is started for 5 seconds, the outdoor fan is started at the medium speed at first, after 30 seconds,it begins to control the airflow speed according to the temperature conditions of the outdoor environment. The temperature of the outdoor air ˄Ta˅ The temperature of the outdoor coil˄Te˅ Airflow speed Ta̱30ć üü High 26ć̰Ta<30ć üü Keeping the speed 24ć̰Ta<26ć üü Medium 23ć̰Ta<24ć üü Keeping the speed 5ć̰Ta<23ć üü Low Ta<5ć 15ć̰Te Low 15ć>Te Stop 5.2.2.2˖The outdoor fan control when heating The temperature of the outdoor air ˄Ta˅ Airflow speed Ta̱22ć Low 19ć̰Ta<22ć Keeping the speed 16ć̰Ta<22ć Medium 14ć̰Ta<16ć Keeping the speed Ta<14ć High 5.2.3˖The control of the outdoor electronic expansion valve When starting the compressor: the opening size of the valve must be guaranteed to have entered into the standard opening size, and then the compressor can be started. When refrigeration is in vain (the machine is shut down or is in the state of retrograde operation), the opening size of the expansion valve of the indoor unit is 5 steps; When heating is in vain, the opening size of the expansion valve of the indoor unit is 55 steps; When the outdoor unit is shut down, the valve is opened completely for 2 minutes, and then begin initialization. The scope of refrigerationg valve 90-----480 steps The scope of heating valve 80-----480 steps The valves are adjusted according to the degree of superheat üSHaˈƸSHa. 5.2.4˖Four way control For the details of defrosting four-way valve control, see the defrosting process. Four way working in other ways: Under the mode of heating, open the four-way valve, when the compressor is not started or changed to non-heating mode, make sure the compressor is stoped for 2 minutes, and then 25 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM close the four-way valve. 5.2.5 Protection function 5.2.5.1 TTC high temperature-preventing protection Once the machine is started, it can run TTC overheating protection of air-blowing, but air-blowing sensor malfunction must alarm after 4 minutes during which the compressor is started (during the course of self-detection, there’s no such limitation) Sensor detection methods: 100 times (one cycle of procedure run is one time, and about 5ms, detection method for each time: continuously sampling for 8 times, then order them and take the mean value of the middle 2 values), take the mean value. TTC Abnormal stop 110 Decreasing the frequency rapidly 1HZ/second 100 Decreasing the frequency slowly (1HZ/10seconds) 98 The frequency doesn’t change. 93 Increasing the frequency (1HZ/10second) 90 Increasing the frequency 1HZ/1second TTC>=110 lasts for 20 seconds. Overheating protection of air-blowing, alarm malfunction to the indoor, others don’t last. 5.2.5.2 TC high temperature-preventing control of the indoor heating unit Tpg_indoor is the highest value of the effective indoor unit (start it and it is in accord with the running state). The indoor heat exchanger sensor tests the temperature of the indoor heat exchanger. If the temperature is higher than 55 , decrease the rotate speed of the compressor and do the high temperature-preventing protection of the indoor heat exchanger; if the temperature of the indoor heat exchanger is lower than 47 , recover to the normal control. TC Fgh_t1 2 N 59 Fgh_t2 2 Fgh_t3 2 Fgh_t4 2 Fgh_t5 2 Normal The compressor stops Fgh_t1 65 Decreasing the frequency rapidly Fgh_t2 P Decreasing the frequency slowly Fgh_t3 55 Q Prohibiting increasing the frequency Fgh_t4 51 R Increasing slowly Fgh_t5 47 N Decreasing at the speed of 1HZ/1 26 second Domestic Air Conditioner 2U14CS1ERA-SM Functions and control P˖Decreasing at the speed of 1Hz/10 ⾦ seconds Q˖Continue to keep the last-time instruction cycle R˖Increasing at the speed of 1Hz/10seconds Remarks: the outdoor unit 5.2.5.3 The control of preventing the overcurrent of the compressor˖ ƽDuring the starting process of the compressor, if the curren of the compressor is greater than 17A for 3 seconds, stop the compressor and alarm, after 3 minutes, start it again, if such state appears 3 times in 20 minutes, stop the compressor and alarm, and confirm the malfunction. Then continue to run it only after the the power is off. ƽDuring the starting process of the compressor, if the AC current is greater than 12A, the frequency of the compressor decreases at the speed of 1HZ/second. ƽDuring the starting process of the compressor, if the AC current is greater than 10A, the frequency of the compressor decreases at the speed of 0.1HZ/second. ƽDuring the starting process of the compressor, if the AC current is greater than 9A, the frequency of the compressor increases at the prohibited speed. ƽDuring the starting process of the compressor, if the AC current is greater than 8A, the frequency of the compressor increases at the speed of no faster than 0.1HZ/second. 5.2.5.4 The protection function of AC current: During the starting process of the compressor, if the AC current is greater than 15A, the frequency of the compressor decreases at the speed of 1HZ/second. During the starting process of the compressor, if the AC current is greater than 13A, the frequency of the compressor decreases at the speed of 0.1HZ/second. During the starting process of the compressor, if the AC current is greater than 11A, the frequency of the compressor increases at the prohibited speed. During the starting process of the compressor, if the AC current is greater than 10A, the frequency of the compressor increases at the speed of no faster than 0.1HZ/second. Remarks: when the outdoor temperature is high, there’s compensation for AC current protection. ŁWhen the outdoor environment temperature is higher than 40ć, AC current protection value decreases by 10AD łWhen the outdoor environment temperature is higher than 46ć,AC current protection value decreases by 15AD ŃWhen the outdoor environment temperature is higher than 50ć,AC current protection value decreases by 20AD 5.2.5.5 Antifreezing protection of the indoor heat exchanger When refrigerating/heating, prevent freezing. Tpg_indoor Ў is the minimum value of the effective indoor unit (start it and it is in accord with the running state). 11ć//ice_temp_3+5 9ć ce_temp_3+3 Increasing slowly 8ć//ice_temp_3+2 Keeping the frequency ice_temp_3 6ć 6ć ice_temp_2 5ć Decreasing slowly ice_temp_1 3ć Decreasing rapidly ice_temp_1 27 Domestic Air Conditioner 2U14CS1ERA-SM 0ć Functions and control Stop When Tpg_indoorLJ ice_temp_1ć, the frequency of the compressor decreases at the speed of 1HZ/1second. When Tpg_indoorLJ ice_temp_2ć, the frequency of the compressor decreases at the speed of 1HZ/10seconds. When Tpg_indoor begins to rise again, and ice_temp_2LJ=Tpg_indoorLJ= ice_temp_3ć, the frequency of thecompressor doesn’t change. When ice_temp_3LJTpg_indoorLJice_temp_3+3ć, the frequency of the compressor increases at the speed of 1HZ/10seconds. For example, Tpg_indoor<= 0ćˈlast for 2 minutes, and then the outdoor unit will stop, and report underload malfunction, but don’t send malfunction report to the indoor. The compressor stops for more than 3 minutes, Tpg_indoor> ice_temp_3+2ć, the compressor recovers. 5.2.5.6 The frequency limitation of modification rate In the field which is controlled by high frequency, if the modification rate is not high enough, the control-driven chip will enter into weak magnetic control, this will help to relieve the problem of modification rate. If during the course of weak magnetic control, the modification rate is still not high enough, enter into the control of decreasing frequency until the alarm of modification rate is relieved. 5.2.5.7 The socket protect If the socket temperature is higher than 120 ć ,the outdoor unit will stop,and report malfunction(the LED light flashing 36 times).The compressor stops for more than 3 minutes,the compressor recovers. 5.2.5.8 Temperature protection of the outdoor refrigerating coil When the defrosting temperature and the sensor’s temperature are higher than 65ć, the frequency of the compressor decreases 1hz/10seconds. Keep the frequency until it decreases to the lowest frequency. When the temperatures are lower than 65ć and higher than 60ć, keep the frequency of the compressor. When the temperatures are lower than 60ć, relieve the defrosting temperature protection. 5.2.5.9˖Malfunction display and malfunction handling a)ǃFor the complete appliance’s malfunctions˖Annex 2 If there’s malfunction with the outdoor unit, the light of the outdoor unit will flash and its frequency is 1HZ, the number of times is according to the table, when a round of flashing is finished, the light shoud be off for 5 seconds. b)ǃFor the units’ malfunctins˖Annex 1 If there’s malfunction with the units, this will not affect the run of the complete appliance, but this can be displayed by the malfunction light, the light flashing frequency is 0.5HZ, the number of times is according to the malfunction table of the indoor units. When a round of flashing is finished, the light shoud be off for 10 seconds. Then report according to the order : unit Aėunit B ėunit Cėunit D, that is, if there’s malfunction with several units, then just report the indoor unit with the highest priority level. Among the unit malfunctions, the priority level of the communication malfunction is the highest, for others, that appears first will have the priority. Remarks: in 3 minutes when the compressor stops, the units’ malfunctions are not displayed; 28 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM the complete appliance’s malfunctions are prior to the units’ malfunctions. Annex 1˖Malfunction codes of the whole unit Remarks: under the mode of refrigeration, the malfunctions of each unit’s thin pipe temperature sensor are not reported, under the mode of heating, the malfunctions of each unit’s thick pipe temperature sensor are not reported. F12 1 Outdoor F1 2 The protection of IPM F22 3 Overcurrent F3 4 Communication fault between the IPM and outdoor PCB F19 6 Power voltage is too high or low F4 8 Overheat protection for exhaust temperature F21 10 Frost-removing temperature sensor failure F6 12 Ambient temperature sensor failure F25 13 Exhaust temperature sensor failure E7 15 Communication fault between indoor and outdoor units F11 18 deviate from the normal ---- 19 Loop E9 21 High work-intense protection --- 24 Overcurrent of the compressor --- 25 Overcurrent protection for single-phase of the compressor ---- 36 The socket protect of EEPROM error protection of AC electricity for the outdoor model for the compressor the station detect error 5.3 Value of Thermistor 5.3.1 intdoor Unit Room sensor and Pipe Sensor R25ć=10K¡f3% B25ć/50ć=3700Kf3% Temp.((ć)) Max.(Kȍ) Normal(Kȍ) Min.(Kȍ) -30 165.2170 147.9497 132.3678 -1.94 1.75 -29 155.5754 139.5600 125.0806 -1.93 1.74 -28 146.5609 131.7022 118.2434 -1.91 1.73 -27 138.1285 124.3392 111.8256 -1.89 1.71 -26 130.2371 117.4366 105.7989 -1.87 1.70 -25 122.8484 110.9627 100.1367 -1.85 1.69 -24 115.9272 104.8882 94.8149 -1.83 1.67 -23 109.4410 99.1858 89.8106 -1.81 1.66 -22 103.3598 93.8305 85.1031 -1.80 1.64 -21 97.6556 88.7989 80.6728 -1.78 1.63 -20 92.3028 84.0695 76.5017 -1.76 1.62 -19 87.2775 79.6222 72.5729 -1.74 1.60 Tolerance(ć) 29 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM -18 82.5577 75.4384 68.8710 -1.72 1.59 -17 78.1230 71.5010 65.3815 -1.70 1.57 -16 73.9543 67.7939 62.0907 -1.68 1.55 -15 70.0342 64.3023 58.9863 -1.66 1.54 -14 66.3463 61.0123 56.0565 -1.64 1.52 -13 62.8755 57.9110 53.2905 -1.62 1.51 -12 59.6076 54.9866 50.6781 -1.60 1.49 -11 56.5296 52.2278 48.2099 -1.58 1.47 -10 53.6294 49.6244 45.8771 -1.56 1.46 -9 50.8956 47.1666 43.6714 -1.54 1.44 -8 48.3178 44.8454 41.5851 -1.51 1.42 -7 45.8860 42.6525 39.6112 -1.49 1.40 -6 43.5912 40.5800 37.7429 -1.47 1.39 -5 41.4249 38.6207 35.9739 -1.45 1.37 -4 39.3792 36.7676 34.2983 -1.43 1.35 -3 37.4465 35.0144 32.7108 -1.41 1.33 -2 35.6202 33.3552 31.2062 -1.38 1.31 -1 33.8936 31.7844 29.7796 -1.36 1.29 0 32.2608 30.2968 28.4267 -1.34 1.28 1 30.7162 28.8875 27.1431 -1.32 1.26 2 29.2545 27.5519 25.9250 -1.29 1.24 3 27.8708 26.2858 24.7686 -1.27 1.22 4 26.5605 25.0851 23.6704 -1.25 1.20 5 25.3193 23.9462 22.6273 -1.23 1.18 6 24.1432 22.8656 21.6361 -1.20 1.16 7 23.0284 21.8398 20.6939 -1.18 1.14 8 21.9714 20.8659 19.7982 -1.15 1.12 9 20.9688 19.9409 18.9463 -1.13 1.09 10 20.0176 19.0621 18.1358 -1.11 1.07 11 19.1149 18.2270 17.3646 -1.08 1.05 12 18.2580 17.4331 16.6305 -1.06 1.03 13 17.4442 16.6782 15.9315 -1.03 1.01 14 16.6711 15.9601 15.2657 -1.01 0.99 15 15.9366 15.2770 14.6315 -0.98 0.96 16 15.2385 14.6268 14.0271 -0.96 0.94 17 14.5748 14.0079 13.4510 -0.93 0.92 18 13.9436 13.4185 12.9017 -0.91 0.90 19 13.3431 12.8572 12.3778 -0.88 0.87 20 12.7718 12.3223 11.8780 -0.86 0.85 21 12.2280 11.8126 11.4011 -0.83 0.83 22 11.7102 11.3267 10.9459 -0.81 0.80 23 11.2172 10.8634 10.5114 -0.78 0.78 24 10.7475 10.4216 10.0964 -0.75 0.75 25 10.3000 10.0000 9.7000 -0.75 0.75 26 9.8975 9.5974 9.2980 -0.76 0.76 30 Domestic Air Conditioner 2U14CS1ERA-SM Functions and control 27 9.5129 9.2132 8.9148 -0.80 0.80 28 9.1454 8.8465 8.5496 -0.84 0.83 29 8.7942 8.4964 8.2013 -0.87 0.86 30 8.4583 8.1621 7.8691 -0.91 0.90 31 8.1371 7.8428 7.5522 -0.95 0.93 32 7.8299 7.5377 7.2498 -0.98 0.97 33 7.5359 7.2461 6.9611 -1.02 1.00 34 7.2546 6.9673 6.6854 -1.06 1.04 35 6.9852 6.7008 6.4222 -1.10 1.07 36 6.7273 6.4459 6.1707 -1.13 1.11 37 6.4803 6.2021 5.9304 -1.17 1.14 38 6.2437 5.9687 5.7007 -1.21 1.18 39 6.0170 5.7454 5.4812 -1.25 1.22 40 5.7997 5.5316 5.2712 -1.29 1.25 41 5.5914 5.3269 5.0704 -1.33 1.29 42 5.3916 5.1308 4.8783 -1.37 1.33 43 5.2001 4.9430 4.6944 -1.41 1.36 44 5.0163 4.7630 4.5185 -1.45 1.40 45 4.8400 4.5905 4.3500 -1.49 1.44 46 4.6708 4.4252 4.1887 -1.53 1.47 47 4.5083 4.2666 4.0342 -1.57 1.51 48 4.3524 4.1145 3.8862 -1.61 1.55 49 4.2026 3.9686 3.7443 -1.65 1.59 50 4.0588 3.8287 3.6084 -1.70 1.62 51 3.9206 3.6943 3.4780 -1.74 1.66 52 3.7878 3.5654 3.3531 -1.78 1.70 53 3.6601 3.4416 3.2332 -1.82 1.74 54 3.5374 3.3227 3.1183 -1.87 1.78 55 3.4195 3.2085 3.0079 -1.91 1.82 56 3.3060 3.0989 2.9021 -1.95 1.85 57 3.1969 2.9935 2.8005 -2.00 1.89 58 3.0919 2.8922 2.7029 -2.04 1.93 59 2.9909 2.7948 2.6092 -2.08 1.97 60 2.8936 2.7012 2.5193 -2.13 2.01 61 2.8000 2.6112 2.4328 -2.17 2.05 62 2.7099 2.5246 2.3498 -2.22 2.09 63 2.6232 2.4413 2.2700 -2.26 2.13 64 2.5396 2.3611 2.1932 -2.31 2.17 65 2.4591 2.2840 2.1195 -2.36 2.21 66 2.3815 2.2098 2.0486 -2.40 2.25 67 2.3068 2.1383 1.9803 -2.45 2.29 68 2.2347 2.0695 1.9147 -2.49 2.34 69 2.1652 2.0032 1.8516 -2.54 2.38 70 2.0983 1.9393 1.7908 -2.59 2.42 71 2.0337 1.8778 1.7324 -2.63 2.46 31 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM 72 1.9714 1.8186 1.6761 -2.68 2.50 73 1.9113 1.7614 1.6219 -2.73 2.54 74 1.8533 1.7064 1.5697 -2.78 2.58 75 1.7974 1.6533 1.5194 -2.83 2.63 76 1.7434 1.6021 1.4710 -2.88 2.67 77 1.6913 1.5528 1.4243 -2.92 2.71 78 1.6409 1.5051 1.3794 -2.97 2.75 79 1.5923 1.4592 1.3360 -3.02 2.80 80 1.5454 1.4149 1.2942 -3.07 2.84 81 1.5000 1.3721 1.2540 -3.12 2.88 82 1.4562 1.3308 1.2151 -3.17 2.93 83 1.4139 1.2910 1.1776 -3.22 2.97 84 1.3730 1.2525 1.1415 -3.27 3.01 85 1.3335 1.2153 1.1066 -3.32 3.06 86 1.2953 1.1794 1.0730 -3.38 3.10 87 1.2583 1.1448 1.0405 -3.43 3.15 88 1.2226 1.1113 1.0092 -3.48 3.19 89 1.1880 1.0789 0.9789 -3.53 3.24 90 1.1546 1.0476 0.9497 -3.58 3.28 91 1.1223 1.0174 0.9215 -3.64 3.33 92 1.0910 0.9882 0.8942 -3.69 3.37 93 1.0607 0.9599 0.8679 -3.74 3.42 94 1.0314 0.9326 0.8424 -3.80 3.46 95 1.0030 0.9061 0.8179 -3.85 3.51 96 0.9756 0.8806 0.7941 -3.90 3.55 97 0.9490 0.8558 0.7711 -3.96 3.60 98 0.9232 0.8319 0.7489 -4.01 3.64 99 0.8983 0.8088 0.7275 -4.07 3.69 100 0.8741 0.7863 0.7067 -4.12 3.74 101 0.8507 0.7646 0.6867 -4.18 3.78 102 0.8281 0.7436 0.6672 -4.23 3.83 103 0.8061 0.7233 0.6484 -4.29 3.88 104 0.7848 0.7036 0.6303 -4.34 3.92 105 0.7641 0.6845 0.6127 -4.40 3.97 106 0.7441 0.6661 0.5957 -4.46 4.02 107 0.7247 0.6482 0.5792 -4.51 4.07 108 0.7059 0.6308 0.5632 -4.57 4.12 109 0.6877 0.6140 0.5478 -4.63 4.16 110 0.6700 0.5977 0.5328 -4.69 4.21 111 0.6528 0.5820 0.5183 -4.74 4.26 112 0.6361 0.5667 0.5043 -4.80 4.31 113 0.6200 0.5518 0.4907 -4.86 4.36 114 0.6043 0.5374 0.4775 -4.92 4.41 115 0.5891 0.5235 0.4648 -4.98 4.45 116 0.5743 0.5100 0.4524 -5.04 4.50 32 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM 117 0.5600 0.4968 0.4404 -5.10 4.55 118 0.5460 0.4841 0.4288 -5.16 4.60 119 0.5325 0.4717 0.4175 -5.22 4.65 120 0.5194 0.4597 0.4066 -5.28 4.70 5.3.2 Outdoor Unit Ambient Sensor, Defrosting Sensor, Pipe sensor R25ć=10K¡f3% B25ć/50ć=3700Kf3% Temp.(ć) Max.(Kȍ) Normal(Kȍ) Min.(Kȍ) -30 165.2170 147.9497 132.3678 -1.94 1.75 -29 155.5754 139.5600 125.0806 -1.93 1.74 -28 146.5609 131.7022 118.2434 -1.91 1.73 -27 138.1285 124.3392 111.8256 -1.89 1.71 -26 130.2371 117.4366 105.7989 -1.87 1.70 -25 122.8484 110.9627 100.1367 -1.85 1.69 -24 115.9272 104.8882 94.8149 -1.83 1.67 -23 109.4410 99.1858 89.8106 -1.81 1.66 -22 103.3598 93.8305 85.1031 -1.80 1.64 -21 97.6556 88.7989 80.6728 -1.78 1.63 -20 92.3028 84.0695 76.5017 -1.76 1.62 -19 87.2775 79.6222 72.5729 -1.74 1.60 -18 82.5577 75.4384 68.8710 -1.72 1.59 -17 78.1230 71.5010 65.3815 -1.70 1.57 -16 73.9543 67.7939 62.0907 -1.68 1.55 -15 70.0342 64.3023 58.9863 -1.66 1.54 -14 66.3463 61.0123 56.0565 -1.64 1.52 -13 62.8755 57.9110 53.2905 -1.62 1.51 -12 59.6076 54.9866 50.6781 -1.60 1.49 -11 56.5296 52.2278 48.2099 -1.58 1.47 -10 53.6294 49.6244 45.8771 -1.56 1.46 -9 50.8956 47.1666 43.6714 -1.54 1.44 -8 48.3178 44.8454 41.5851 -1.51 1.42 -7 45.8860 42.6525 39.6112 -1.49 1.40 -6 43.5912 40.5800 37.7429 -1.47 1.39 -5 41.4249 38.6207 35.9739 -1.45 1.37 -4 39.3792 36.7676 34.2983 -1.43 1.35 -3 37.4465 35.0144 32.7108 -1.41 1.33 -2 35.6202 33.3552 31.2062 -1.38 1.31 -1 33.8936 31.7844 29.7796 -1.36 1.29 0 32.2608 30.2968 28.4267 -1.34 1.28 1 30.7162 28.8875 27.1431 -1.32 1.26 2 29.2545 27.5519 25.9250 -1.29 1.24 3 27.8708 26.2858 24.7686 -1.27 1.22 4 26.5605 25.0851 23.6704 -1.25 1.20 5 25.3193 23.9462 22.6273 -1.23 1.18 Tolerance(ć) 33 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM 6 24.1432 22.8656 21.6361 -1.20 1.16 7 23.0284 21.8398 20.6939 -1.18 1.14 8 21.9714 20.8659 19.7982 -1.15 1.12 9 20.9688 19.9409 18.9463 -1.13 1.09 10 20.0176 19.0621 18.1358 -1.11 1.07 11 19.1149 18.2270 17.3646 -1.08 1.05 12 18.2580 17.4331 16.6305 -1.06 1.03 13 17.4442 16.6782 15.9315 -1.03 1.01 14 16.6711 15.9601 15.2657 -1.01 0.99 15 15.9366 15.2770 14.6315 -0.98 0.96 16 15.2385 14.6268 14.0271 -0.96 0.94 17 14.5748 14.0079 13.4510 -0.93 0.92 18 13.9436 13.4185 12.9017 -0.91 0.90 19 13.3431 12.8572 12.3778 -0.88 0.87 20 12.7718 12.3223 11.8780 -0.86 0.85 21 12.2280 11.8126 11.4011 -0.83 0.83 22 11.7102 11.3267 10.9459 -0.81 0.80 23 11.2172 10.8634 10.5114 -0.78 0.78 24 10.7475 10.4216 10.0964 -0.75 0.75 25 10.3000 10.0000 9.7000 -0.75 0.75 26 9.8975 9.5974 9.2980 -0.76 0.76 27 9.5129 9.2132 8.9148 -0.80 0.80 28 9.1454 8.8465 8.5496 -0.84 0.83 29 8.7942 8.4964 8.2013 -0.87 0.86 30 8.4583 8.1621 7.8691 -0.91 0.90 31 8.1371 7.8428 7.5522 -0.95 0.93 32 7.8299 7.5377 7.2498 -0.98 0.97 33 7.5359 7.2461 6.9611 -1.02 1.00 34 7.2546 6.9673 6.6854 -1.06 1.04 35 6.9852 6.7008 6.4222 -1.10 1.07 36 6.7273 6.4459 6.1707 -1.13 1.11 37 6.4803 6.2021 5.9304 -1.17 1.14 38 6.2437 5.9687 5.7007 -1.21 1.18 39 6.0170 5.7454 5.4812 -1.25 1.22 40 5.7997 5.5316 5.2712 -1.29 1.25 41 5.5914 5.3269 5.0704 -1.33 1.29 42 5.3916 5.1308 4.8783 -1.37 1.33 43 5.2001 4.9430 4.6944 -1.41 1.36 44 5.0163 4.7630 4.5185 -1.45 1.40 45 4.8400 4.5905 4.3500 -1.49 1.44 46 4.6708 4.4252 4.1887 -1.53 1.47 47 4.5083 4.2666 4.0342 -1.57 1.51 48 4.3524 4.1145 3.8862 -1.61 1.55 49 4.2026 3.9686 3.7443 -1.65 1.59 50 4.0588 3.8287 3.6084 -1.70 1.62 34 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM 51 3.9206 3.6943 3.4780 -1.74 1.66 52 3.7878 3.5654 3.3531 -1.78 1.70 53 3.6601 3.4416 3.2332 -1.82 1.74 54 3.5374 3.3227 3.1183 -1.87 1.78 55 3.4195 3.2085 3.0079 -1.91 1.82 56 3.3060 3.0989 2.9021 -1.95 1.85 57 3.1969 2.9935 2.8005 -2.00 1.89 58 3.0919 2.8922 2.7029 -2.04 1.93 59 2.9909 2.7948 2.6092 -2.08 1.97 60 2.8936 2.7012 2.5193 -2.13 2.01 61 2.8000 2.6112 2.4328 -2.17 2.05 62 2.7099 2.5246 2.3498 -2.22 2.09 63 2.6232 2.4413 2.2700 -2.26 2.13 64 2.5396 2.3611 2.1932 -2.31 2.17 65 2.4591 2.2840 2.1195 -2.36 2.21 66 2.3815 2.2098 2.0486 -2.40 2.25 67 2.3068 2.1383 1.9803 -2.45 2.29 68 2.2347 2.0695 1.9147 -2.49 2.34 69 2.1652 2.0032 1.8516 -2.54 2.38 70 2.0983 1.9393 1.7908 -2.59 2.42 71 2.0337 1.8778 1.7324 -2.63 2.46 72 1.9714 1.8186 1.6761 -2.68 2.50 73 1.9113 1.7614 1.6219 -2.73 2.54 74 1.8533 1.7064 1.5697 -2.78 2.58 75 1.7974 1.6533 1.5194 -2.83 2.63 76 1.7434 1.6021 1.4710 -2.88 2.67 77 1.6913 1.5528 1.4243 -2.92 2.71 78 1.6409 1.5051 1.3794 -2.97 2.75 79 1.5923 1.4592 1.3360 -3.02 2.80 80 1.5454 1.4149 1.2942 -3.07 2.84 81 1.5000 1.3721 1.2540 -3.12 2.88 82 1.4562 1.3308 1.2151 -3.17 2.93 83 1.4139 1.2910 1.1776 -3.22 2.97 84 1.3730 1.2525 1.1415 -3.27 3.01 85 1.3335 1.2153 1.1066 -3.32 3.06 86 1.2953 1.1794 1.0730 -3.38 3.10 87 1.2583 1.1448 1.0405 -3.43 3.15 88 1.2226 1.1113 1.0092 -3.48 3.19 89 1.1880 1.0789 0.9789 -3.53 3.24 90 1.1546 1.0476 0.9497 -3.58 3.28 91 1.1223 1.0174 0.9215 -3.64 3.33 92 1.0910 0.9882 0.8942 -3.69 3.37 93 1.0607 0.9599 0.8679 -3.74 3.42 94 1.0314 0.9326 0.8424 -3.80 3.46 95 1.0030 0.9061 0.8179 -3.85 3.51 35 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM 96 0.9756 0.8806 0.7941 -3.90 3.55 97 0.9490 0.8558 0.7711 -3.96 3.60 98 0.9232 0.8319 0.7489 -4.01 3.64 99 0.8983 0.8088 0.7275 -4.07 3.69 100 0.8741 0.7863 0.7067 -4.12 3.74 101 0.8507 0.7646 0.6867 -4.18 3.78 102 0.8281 0.7436 0.6672 -4.23 3.83 103 0.8061 0.7233 0.6484 -4.29 3.88 104 0.7848 0.7036 0.6303 -4.34 3.92 105 0.7641 0.6845 0.6127 -4.40 3.97 106 0.7441 0.6661 0.5957 -4.46 4.02 107 0.7247 0.6482 0.5792 -4.51 4.07 108 0.7059 0.6308 0.5632 -4.57 4.12 109 0.6877 0.6140 0.5478 -4.63 4.16 110 0.6700 0.5977 0.5328 -4.69 4.21 111 0.6528 0.5820 0.5183 -4.74 4.26 112 0.6361 0.5667 0.5043 -4.80 4.31 113 0.6200 0.5518 0.4907 -4.86 4.36 114 0.6043 0.5374 0.4775 -4.92 4.41 115 0.5891 0.5235 0.4648 -4.98 4.45 116 0.5743 0.5100 0.4524 -5.04 4.50 117 0.5600 0.4968 0.4404 -5.10 4.55 118 0.5460 0.4841 0.4288 -5.16 4.60 119 0.5325 0.4717 0.4175 -5.22 4.65 120 0.5194 0.4597 0.4066 -5.28 4.70 Discharging Sensor R80ć=50K¡f3% B25/80ć=4450Kf3% Temp.((ć)) Max.(Kȍ) Normal(Kȍ) Min.(Kȍ) -30 14646.0505 12061.7438 9924.4999 -2.96 2.45 -29 13654.1707 11267.8730 9290.2526 -2.95 2.44 -28 12735.8378 10531.3695 8700.6388 -2.93 2.44 -27 11885.1336 9847.7240 8152.2338 -2.92 2.43 -26 11096.6531 9212.8101 7641.8972 -2.91 2.42 -25 10365.4565 8622.8491 7166.7474 -2.90 2.42 -24 9687.0270 8074.3787 6724.1389 -2.88 2.41 -23 9057.2314 7564.2244 6311.6413 -2.87 2.41 -22 8472.2852 7089.4741 5927.0206 -2.86 2.40 -21 7928.7217 6647.4547 5568.2222 -2.84 2.39 -20 7423.3626 6235.7109 5233.3554 -2.83 2.39 -19 6953.2930 5851.9864 4920.6791 -2.82 2.38 -18 6515.8375 5494.2064 4628.5894 -2.80 2.37 -17 6108.5393 5160.4621 4355.6078 -2.79 2.37 -16 5729.1413 4848.9963 4100.3708 -2.77 2.36 Tolerance(ć) 36 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM -15 5375.5683 4558.1906 3861.6201 -2.76 2.35 -14 5045.9114 4286.5535 3638.1938 -2.75 2.34 -13 4738.4141 4032.7098 3429.0191 -2.73 2.34 -12 4451.4586 3795.3910 3233.1039 -2.72 2.33 -11 4183.5548 3573.4260 3049.5312 -2.70 2.32 -10 3933.3289 3365.7336 2877.4527 -2.69 2.31 -9 3699.5139 3171.3148 2716.0828 -2.67 2.30 -8 3480.9407 2989.2460 2564.6945 -2.66 2.29 -7 3276.5302 2818.6731 2422.6139 -2.64 2.28 -6 3085.2854 2658.8058 2289.2164 -2.63 2.28 -5 2906.2851 2508.9126 2163.9230 -2.61 2.27 -4 2738.6777 2368.3158 2046.1961 -2.60 2.26 -3 2581.6752 2236.3876 1935.5371 -2.58 2.25 -2 2434.5487 2112.5459 1831.4826 -2.56 2.24 -1 2296.6230 1996.2509 1733.6024 -2.55 2.23 0 2167.2730 1887.0018 1641.4966 -2.53 2.22 1 2045.9191 1784.3336 1554.7931 -2.52 2.21 2 1932.0242 1687.8144 1473.1460 -2.50 2.20 3 1825.0899 1597.0431 1396.2333 -2.48 2.19 4 1724.6540 1511.6468 1323.7551 -2.47 2.17 5 1630.2870 1431.2787 1255.4324 -2.45 2.16 6 1541.5904 1355.6163 1191.0048 -2.43 2.15 7 1458.1938 1284.3593 1130.2298 -2.41 2.14 8 1379.7528 1217.2282 1072.8813 -2.40 2.13 9 1305.9472 1153.9626 1018.7481 -2.38 2.12 10 1236.4792 1094.3200 967.6334 -2.36 2.11 11 1171.0715 1038.0743 919.3533 -2.35 2.09 12 1109.4661 985.0146 873.7359 -2.33 2.08 13 1051.4226 934.9440 830.6210 -2.31 2.07 14 996.7169 887.6792 789.8583 -2.29 2.06 15 945.1404 843.0486 751.3077 -2.27 2.04 16 896.4981 800.8922 714.8380 -2.26 2.03 17 850.6086 761.0603 680.3265 -2.24 2.02 18 807.3024 723.4134 647.6580 -2.22 2.00 19 766.4212 687.8205 616.7252 -2.20 1.99 20 727.8172 654.1596 587.4271 -2.18 1.98 21 691.3524 622.3161 559.6694 -2.16 1.96 22 656.8979 592.1831 533.3634 -2.14 1.95 23 624.3328 563.6604 508.4261 -2.12 1.93 24 593.5446 536.6540 484.7796 -2.10 1.92 25 564.4275 511.0760 462.3510 -2.09 1.90 26 536.9865 486.9352 441.1516 -2.07 1.89 27 511.0105 464.0500 421.0258 -2.05 1.87 28 486.4151 442.3499 401.9146 -2.03 1.86 29 463.1208 421.7683 383.7626 -2.01 1.84 37 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM 30 441.0535 402.2430 366.5175 -1.99 1.83 31 420.1431 383.7151 350.1301 -1.97 1.81 32 400.3242 366.1295 334.5542 -1.95 1.80 33 381.5350 349.4341 319.7460 -1.93 1.78 34 363.7176 333.5801 305.6645 -1.90 1.76 35 346.8176 318.5216 292.2709 -1.88 1.75 36 330.7839 304.2151 279.5286 -1.86 1.73 37 315.5682 290.6199 267.4031 -1.84 1.71 38 301.1254 277.6976 255.8620 -1.82 1.70 39 287.4128 265.4119 244.8745 -1.80 1.68 40 274.3905 253.7288 234.4118 -1.78 1.66 41 262.0206 242.6161 224.4465 -1.76 1.64 42 250.2676 232.0436 214.9529 -1.74 1.63 43 239.0983 221.9825 205.9065 -1.71 1.61 44 228.4809 212.4060 197.2844 -1.69 1.59 45 218.3860 203.2887 189.0648 -1.67 1.57 46 208.7855 194.6066 181.2273 -1.65 1.55 47 199.6531 186.3369 173.7524 -1.63 1.54 48 190.9639 178.4584 166.6217 -1.60 1.52 49 182.6945 170.9508 159.8181 -1.58 1.50 50 174.8228 163.7951 153.3249 -1.56 1.48 51 167.3280 156.9733 147.1268 -1.53 1.46 52 160.1904 150.4683 141.2090 -1.51 1.44 53 153.3914 144.2641 135.5577 -1.49 1.42 54 146.9136 138.3454 130.1598 -1.47 1.40 55 140.7403 132.6980 125.0027 -1.44 1.38 56 134.8559 127.3081 120.0746 -1.42 1.36 57 129.2457 122.1630 115.3645 -1.40 1.34 58 123.8956 117.2504 110.8618 -1.37 1.32 59 118.7926 112.5589 106.5564 -1.35 1.30 60 113.9241 108.0776 102.4388 -1.32 1.28 61 109.2784 103.7961 98.5000 -1.30 1.26 62 104.8443 99.7046 94.7315 -1.28 1.23 63 100.6112 95.7939 91.1253 -1.25 1.21 64 96.5692 92.0553 87.6735 -1.23 1.19 65 92.7088 88.4805 84.3690 -1.20 1.17 66 89.0211 85.0614 81.2048 -1.18 1.15 67 85.4976 81.7908 78.1744 -1.15 1.12 68 82.1303 78.6615 75.2715 -1.13 1.10 69 78.9116 75.6668 72.4902 -1.10 1.08 70 75.8343 72.8004 69.8249 -1.08 1.06 71 72.8916 70.0561 67.2703 -1.05 1.03 72 70.0770 67.4283 64.8213 -1.03 1.01 73 67.3844 64.9115 62.4731 -1.00 0.99 74 64.8080 62.5006 60.2211 -0.98 0.96 38 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM 75 62.3423 60.1906 58.0609 -0.95 0.94 76 59.9821 57.9770 55.9885 -0.92 0.92 77 57.7223 55.8552 53.9998 -0.90 0.89 78 55.5583 53.8210 52.0912 -0.87 0.87 79 53.4856 51.8706 50.2591 -0.85 0.84 80 51.5000 50.0000 48.5000 -0.85 0.84 81 49.7063 48.2057 46.7083 -0.85 0.85 82 47.9835 46.4842 44.9911 -0.89 0.89 83 46.3286 44.8323 43.3452 -0.93 0.92 84 44.7385 43.2468 41.7672 -0.96 0.95 85 43.2105 41.7248 40.2540 -1.00 0.99 86 41.7386 40.2604 38.7996 -1.03 1.02 87 40.3241 38.8545 37.4048 -1.07 1.06 88 38.9643 37.5045 36.0668 -1.11 1.09 89 37.6569 36.2078 34.7831 -1.14 1.13 90 36.3996 34.9622 33.5513 -1.18 1.16 91 35.1903 33.7653 32.3689 -1.22 1.19 92 34.0269 32.6151 31.2338 -1.26 1.23 93 32.9075 31.5096 30.1438 -1.30 1.27 94 31.8302 30.4467 29.0970 -1.33 1.30 95 30.7933 29.4246 28.0915 -1.37 1.34 96 29.7950 28.4417 27.1254 -1.41 1.37 97 28.8337 27.4961 26.1970 -1.45 1.41 98 27.9078 26.5864 25.3048 -1.49 1.44 99 27.0160 25.7110 24.4470 -1.53 1.48 100 26.1569 24.8685 23.6222 -1.57 1.52 101 25.3290 24.0574 22.8291 -1.61 1.55 102 24.5311 23.2765 22.0662 -1.65 1.59 103 23.7620 22.5245 21.3323 -1.69 1.63 104 23.0205 21.8002 20.6261 -1.73 1.66 105 22.3055 21.1025 19.9465 -1.77 1.70 106 21.6159 20.4303 19.2924 -1.81 1.74 107 20.9508 19.7825 18.6626 -1.85 1.77 108 20.3091 19.1582 18.0563 -1.89 1.81 109 19.6899 18.5564 17.4723 -1.93 1.85 110 19.0924 17.9761 16.9098 -1.98 1.89 111 18.5157 17.4166 16.3680 -2.02 1.93 112 17.9590 16.8769 15.8458 -2.06 1.96 113 17.4214 16.3564 15.3427 -2.10 2.00 114 16.9023 15.8542 14.8577 -2.15 2.04 115 16.4010 15.3696 14.3902 -2.19 2.08 116 15.9167 14.9020 13.9394 -2.23 2.12 117 15.4489 14.4506 13.5047 -2.27 2.16 118 14.9968 14.0149 13.0855 -2.32 2.19 119 14.5599 13.5942 12.6811 -2.36 2.23 39 Domestic Air Conditioner Functions and control 2U14CS1ERA-SM 120 14.1376 13.1879 12.2909 -2.41 2.27 121 13.7294 12.7955 11.9144 -2.45 2.31 122 13.3347 12.4165 11.5510 -2.50 2.35 123 12.9531 12.0503 11.2003 -2.54 2.39 124 12.5840 11.6965 10.8617 -2.58 2.43 125 12.2270 11.3545 10.5348 -2.63 2.47 126 11.8817 11.0240 10.2191 -2.68 2.51 127 11.5475 10.7046 9.9142 -2.72 2.55 128 11.2242 10.3957 9.6197 -2.77 2.59 129 10.9112 10.0970 9.3352 -2.81 2.63 130 10.6084 9.8082 9.0602 -2.86 2.67 131 10.3151 9.5288 8.7945 -2.91 2.71 132 10.0312 9.2586 8.5378 -2.95 2.75 133 9.7563 8.9971 8.2895 -3.00 2.80 134 9.4901 8.7441 8.0495 -3.05 2.84 135 9.2322 8.4993 7.8175 -3.09 2.88 136 8.9824 8.2623 7.5931 -3.14 2.92 137 8.7404 8.0329 7.3760 -3.19 2.96 138 8.5059 7.8108 7.1660 -3.24 3.00 139 8.2787 7.5958 6.9629 -3.29 3.04 140 8.0584 7.3875 6.7664 -3.33 3.09 40 Domestic Air Conditioner 2U14CS1ERA-SM 41 2U14CS1ERA-SM Introduction Parts and Functions Remote controller Indoor Unit 1 6 8.Additional functions display Operation mode QUITE SLEEP Inlet Air Purifying Filter 2 (inside) Remote controller 7 3 4 Inlet grille 5 8 9 Outlet 18 10 Vertical blade (adjust left and right air fl ow) Horizontal flap 13 21 Control the lightening and extinguishing of the indoor LED display board. 14 23 15 24 16 25 17 Display board 1 1. Mode display 2 3 4 Operation mode 5 AUTO COOL DRY HEAT FAN Remote controller 2. Signal sending display 3. SWING display 4. FAN SPEED display 4 TIMER ON\OFF display 1 Signal receiver hole TIMER ON-OFF display 2 ON/OFF display SLEEP display 3 Ambient temp.display Note to the power failure resume: When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference. LO MED HI Display circulated AUTO 5. LOCK display 6. TIMER OFF display TIMER ON display 7.TEMP display press the sleep button ten times in five seconds and enter function after hearing four sounds.And press the sleep button ten times within five seconds and leave this function after hearing two sounds. Used to lock buttons and LCD display. 17. LIGHT button 22 Please be subject to the actual produce purchased the above picture is just from your reference 9. QUIET button 10. HEAT button 11. COOL button 12. AUTO button 13. FAN button 14. TIMER button 15. HEALTH button 16. LOCK button 20 12 Display board (adjust up and down air flow Don't adjust it manually) 19 11 Emergency Switch Supplemented electrical HEALTH POWER heating 18. POWER ON/OFF button 19. DRY button 20. TEMP button 21. SWING button 22. HOUR button 23. EXTRA FUNCTION button Function: Air sending--- Healthy airflow position1--- Healthy airflow position 2 --- Restore the original flap position --- Right & left air airflow--- A-B yard--10 and heating symbol displayed simultaneously--- Sleeping--- Electrical heating--- Refresh air(reserved function) --- Power--- Fahrenheit/Celsius mode conversion 24.CANCEL/CONFIRM button Function: Setting and cancel to the timer and other additional functions. 25. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote Healthy function is not available for some units. 5 COOL\HEAT\Dry\AUTO display Loading of the battery Outdoor Unit 1 Remove the battery cover; 2 Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder); Be sure that the loading is in line with the" + "/"-"; Load the battery,then put on the cover again. 3 4 Note: The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. When electronic-started type fluorescent lamp or change- over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter. Full display or unclear display during operation indicates the batteries have been used up. Please change batteries. If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. 4 OUTLET INLET CONNECTING PIPING AND ELECTRICAL WIRING 4 DRAIN HOSE Please be subject to the actual produce purchased the above picture is just from your reference Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key. 42 Domestic air conditioner 2U14CS1ERA-SM Introduction Operation Base Operation Emergency operation and test operation Emergency Operation: Remote controller Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes: Pi 1 2 3 4 3 Room Designated Timer Fan Operation temperature temperature mode speed mode o 26 C o 23 C Above 23 C Below 23 C o o No AUTO COOL No AUTO HEAT It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode. 1. Unit start Press ON/OFF on the remote controller, unit starts. Test operation: 2. Select operation mode Test ope ration switch is the same as emergency switch. COOL button:Cooling mode HEAT button: Heating mode DRY button: Dehumidify mode Use this switch in the test operation when the room o temperature is below 16 C, do not use it in the normal operation. 3.Select temp.setting switch for more than 5 seconds . After you hear the "Pi" sound twice, release button Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly Select a desired temperature. Press / your finger from the switch: the cooling operation starts with the air flow speed "Hi". Under this operation mode,the fan motor of indoor unit will run in high speed. Air Flow Direction Adjustment 4.Fan speed selection 1.Status display of air flow Press FAN button. For each press, fan speed changes as follows: Remote controller: LOW MED COOL/DRY: Display circulated AUTO HI HEAT: Initial state 2.Left and right air flow adjustment(manual) Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. Operation Mode AUTO Remote Controller Pi Pi Continue to press the test operation Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig. Note Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature. Cautions: COOL DRY In DRY mode , when room temperature becomes lower than temp.setting+2 o C, unit will run intermittently at LOW speed regardless of FAN setting. HEAT In HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. FAN In FAN operation mode , the unit will not operate in COOL or HEAT mode but only in FAN mode, AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, sleep operation is not available. 43 3D When adjusting the flap by hand,turn off the unit. When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right. It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur. Note: When restart after remote turning off, the remote controller will automatically memorize the previous set swing position. Domestic air conditioner 2U14CS1ERA-SM Introduction Operation Sleep Operation 4. In FAN mode It has no SLEEP function. Press button to enter additional options, when cycle display to , will flash. And then press enter to sleep function. 5.Set the wind speed change when sleeping If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change. Note When TIMER function is set, the sleeping function can’t be set up .After the sleeping function is set up , if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on. POWER/QUIET Operation (1) POWER Operation Operation Mode 1. In COOL,DRY mode When you need rapid heating or cooling, you can use this function. 1 hours after SLEEP mode starts,temp.will become 1OC higher than temp.setting.After another 1 hours,temp.rises by 1OC futher.The unit will run for further 6 hours then stops Temp. is higher than temp.setting so that room temperature won’t be too low for your sleep. SLEEP operation starts additional options again and to cancel power function. Press QUIET button, the remote controller will show and then achieve to the quiet function. Press again this QUIET button , the quiet function will be cancelled. Rises 1OC Temp.setting Unit stop 2. In HEAT mode 1 hours after SLEEP mode starts,temp will become 2OC lower than temp.setting.After another 1 hours,temp decrease by 2 OC futher.After more another 3 hours,temp. rises by 1OC futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep. Temp.setting During POWER operation, in rapid HEAT or COOL mode , the room will show inhomogeneous temperature distribution. Long period QUIET operation will cause effect of not too cool or not too warm. Unit stop Decreases 2OC 1 hr Decreases 2OC 3 hrs 3 hrs Rises 1OC SLEEP operation stops SLEEP operation starts In HEAT mode 3. In AUTO mode The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode. 44 4 , Note ˖ In COOL, DRY mode 1 hr display to , will flash,and then press ,enter to power function. When cancel the function, please enter You can use this function when silence is needed for rest or reading. Rises 1OC 1 hr button to enter additional options, when cycle (2) QUIET Operation SLEEP operation stops Approx.6hrs 1 hr Press Domestic air conditioner 2U14CS1ERA-SM EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS Operation CE Timer On/Off On-Off Operation All the products are in conformity with the following European provision: - Low Voltage Directive 73/23/EEC - Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC 1.After unit starts, select your desired operation mode. 2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK 0.5h 0.5h TIMER ON TIMER OFF ROHS 0.5h 0.5h TIMER ON-OFF TIMER OFF-ON Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash. 3.Press / button to set time. Press the button for each time, setting time in the first 12 hours increased by 0.5 hour every time, after 12 hours,increased by 1 hour every time. Press the button for each time, settiing time in the first 12 hours decreased by 0.5 hour every time, after 12 hours,decreased by 1 hour every time. It can be adjusted within 24 hours. 4.Confirm timer setting After adjust the time,press button and confirm the time ON or OFF button will not flash any more. 5.Cancel timer setting Press the timer button by times until the time display eliminated. Hints: After replacing batteries or a power failure happens, time setting should be reset. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved. Healthy airflow Operation 1.Press to starting Setting the comfort work conditions. 2.The setting of healthy airflow function Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations, to choose the swing location what you needed,and then press button to confirm. Healthy airflow upwarder Healthy airflow downwarder Present position The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive) WEEE In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products. DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol.This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself : the dismantling of the air conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and nationl legislation. IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED Contains fluorinated greenhouse gases covered by the Kyoto Protocol R410A 1= kg 2 2= kg 1+2= kg 1 3.The cancel of the healthy airflow function Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations again,and then press button to cancel. Notice: Do not direct the flap by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop for a minute and then start, adjusting by remote controller. Note: 1.After setting the healthy airflow function, the position grill is fixed. 2.In heating, it is better to select the mode. 3.In cooling, it is better to select the mode. 4.In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may occur at the grille . Introduction F A B C D E This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere. Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink, •1 the factory refrigerant charge of the product •2 the additional refrigerant amount charged in the field and • 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging 45 Domestic air conditioner 2U14CS1ERA-SM Introduction Indoor Unit Installaion Necessary Tools for Installation ● ● ● ● ● ● Driver Nipper Hacksaw Hole core drill Spanner(17,19 and 26mm) Gas leakage detector or soap-and-water solution ● Torque wrench (17mm,22mm,26mm) ● Pipe cutter ● Flaring tool ● Knife ● Measuring tape ● Reamer Power Source ● Before inserting power into receptacle, check the voltage without fail. ● The power supply is the same as the corresponding nameplate. ● Install an exclusive branch circuit of the power. ● A receptacle shall be set up in a distance where the power cable can be reached.Do not extend the cable by cutting it. Selection of Installation Place Accessory Parts ● Place, robust not causing vibration, where the body can be supported sufficiently. ● Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed. ● Place, possible to drain easily, where piping can be connected with the outdoor unit. ● Place, where cold air can be spread in a room entirely. ● Place, nearby a power receptacle, with enough space around. ● Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. ● In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened. Remote controller (1) Drain hose (1) R-03 dry battery (2) Plastic cap (4) Ø4X25 Screw (4) Mounting plate (1) Air purifying filter(Optional) (1) Selection of Pipe FOR 07K 09K 12K FOR 18K FOR 24K Drawing for the installation of indoor units The models adopt HFC free refrigerant R410A Attention must be paid to the rising up of drain hose more than 15 cm Arrangement of piping directions Rear left more than 10cm Rear right Left Right Below more than 10cm The distance between the indoor unit and the floor should be more than 2m. Please be subject to the actual product purchased,the above picture is just for your reference. 46 6 Domestic air conditioner 2U14CS1ERA-SM Introduction Indoor Unit Installation 1 Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail. 3. Find the wall hole location A using a measuring tape [ Left· Left-rear piping ] ● In case of left side piping, cut away, with a nipper, the lid for left piping. ● In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials. 1. Insert the drain hose into the dent of heat insulation materials of indoor unit. 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Indoor/outdoor electric cable Heat insulation material B= Ø 70mm Lid for right piping Piping Pipe supporting plate Lid for left piping Drain hose Lid for under piping pipe Fix with adhesive tape 30mm A=145mm ● Indoor/outdoor electric cable and drain hose must be bound with efrigerant piping by protecting tape. [ Other direction piping ] ● Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to theposition of wall hole. When bending, be careful not to crash pipes. ● Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially. 35mm B= 70mm A=150mm B= Ø 70mm ● Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing. ● In order to fix the body onto the mounting plate,hold up the body aslant from the underside and then put it down perpendicularly. 30mm A=145mm Fixing the indoor unit body When the mounting plate is fixed side bar and lintel ● Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten the plate to the fixed mounting bar. ● Refer to the previous article, “ When the mounting plate is first fixed “, for the position of wall hole. 2 Making a Hole on the Wall and Fitting the Piping Hole Cover mounting plate Unloading of indoor unit body ● When you unload the indoor unit,please use your hand to arise the body to leave agraffe,then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate. ● Make a hole of 70 mm in diameter, slightly descending to outside the wall ● Install piping hole cover and seal it off with putty after installation Wall hole Ø70mm agraffe Indoor side (Section of wall hole) 3 Outdoor side 4 Thickness of wall mounting plate Connecting the indoor/outdoor Electric Cable G Piping hole pipe Installation of the Indoor Unit Removing the wiring cover ● Drawing of pipe Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. [ Rear piping ] ● Draw pipes and the drain hose, then fasten them with the adhesive tape 47 6 Domestic air conditioner 2U14CS1ERA-SM Correct When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable making a loop. ƽ ƽ Incorrect Lean When connecting the cable before installing the indoor unit ƽ Insert the cable from the back ƽ Loosen the screws and insert Introduction Damage of flare Crack Partial Too outside On Drainage ƽ Please install the drain hose so as to be downward slope without fail. ƽ Please don’t do the drainage as shown below. side of the unit, then pull it out on the front side. the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Less than 5cm It becomes The end is imm- It waves. The gap with the There is the bad high midway. ersed in water. ground is too small. smell from a ditch Indoor unit ƽ Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out surely to outdoor. ƽ In case that the attached drain hose is in a room, please apply heat insulation to it without fail. To Outdoor unit Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. Model AS07GS2ERA AS09GS2ERA AS12GS2ERA Connecting wiring 4G0.75mm AS24GS2ERA AS18GS2ERA 2 4G0.75mm 2 4G0.75mm 2 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F. 2. If the fuse on PC board is broken please change it with the type of T.3.15A/250VAC (Indoor). 3. The wiring method should be in line with the local wiring standard. 4. After installation, the power plug should be easily reached. 5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. Power Source Installation ƽThe power source must be exclusively used for air conditioner. ƽ In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. ƽ For installation in other places, use a circuit breaker as far as possible. Cutting and Flaring Work of Piping ƽ Pipe cutting is carried out with a pipe cutter and burs must be removed. ƽ After inserting the flare nut, flaring work is carried out. A Flare tool for R410A Conventional flare tool Clutch-type clutch-type(Rigid-type) Wing-nut type (Imperial-type) 0~0.5mm Flare tooling die 1.0~1.5mm 1.Cut pipe 3.Insert the flare nut 1.5~2.0mm 2.Remove burs 4.Flare pipe On Drainage C ode T rouble description indication Indoor fan m otor E1 m alfunction H eat-exc hange E2 sensor failure A nalyze and diagnose F aulty connector c onnection; F aulty therm istor; F aulty P C B ; E4 Indoor E E P R O M error F aulty E E P R O M data; F aulty E E P R O M ; F aulty P C B ; E7 C om m unication fault betw een indoor and outdoor units Indoor unit- outdoor unit s ignal tra n s m is s io n e rror du e to w irin g error; F aulty P C B ; Indoor fan m otor m alfunction O peration halt due to breaking of w ire inside the fan m otor; O peration halt due to breaking of the fan m otor lead w ires; D etec tion error due to faulty indoor unit P C B ; E 14 Check for Installation and Test Run Ƶ Please kindly explain to our customers how to operate through the instruction manual. Check Items for Test Run Put check mark in boxes Gas leak from pipe connecting? Heat insulation of pipe connecting? Are the connecting wirings of indoor and outdoor firmly inserted to the terminal block? Is the connecting wiring of indoor and outdoor firmly fixed? Is drainage securely carried out? Is the earth line securely connected? Is the indoor unit securely fixed? Is power source voltage abided by the code? Is there any noise? Is the lamp normally lighting? Are cooling and heating (when in heat pump) performed normally? Is the operation of room temperature regulator normal? 48 6 Domestic air conditioner 2U14CS1ERA-SM Introduction Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Remote Controller Do not block the air inlet or outlet Indoor Body Proper temperature wipe the air conditioner by using a soft and dry cloth.For serious stains, use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely. Do not usewater,wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth. Do not use the following for cleaning Use the timer effectively Close doors and windows during operation Gasoline,benzine, thinner or cleanser may damage the coating of the unit. Hot water over 40 O C(104O F) may cause discoloring or deformation. Air Filter cleaning During cooling operation prevent the penetration of direct sunlight with curtain or blind Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. Clean the filter. Use the louvers effectively If the unit is not to be used for a long time, turn off the power supply main switch. Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects. OFF Once every two weeks Close the inlet grille. Replacement of Air Purifying Filter 1.Open the lnlet Grille 4.Attach the standard air filter Prop up the inlet grille by using a small device named grille-support which located in the right side of the indoor unit. (Necessary installation) ATTENTION: The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green side of the bacteria-killing medium air purifying filter face outside,and the white side face the unit. 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 5.Close the Inlet Grille Close the Grille surely NOTE: Detach old Air Purifying Filter The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by using vacuum cleaner or flaping them lightly,otherwise , its performance will be affected. 3.Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames. Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it,or its ability of sterilization will be reduced. reduced. 49 6 Domestic air conditioner 2U14CS1ERA-SM Introduction Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Check proper installation of the drainage securely Use an exclusive power source with a circuit breaker STRICT ENFORCEMENT OFF Connect power supply cord to the outlet completely STRICT ENFORCEMENT Use the proper voltage STRICT STRICT ENFORCEMENT ENFORCEMENT Take care not to damage Do not use power supply the power supply cord. cord in a bundle. PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on. 1.Do not use power supply cord extended or connected in halfway 2.Do not install in the place where there is any possibility of inflammable gas leakage around the unit. 3.Do not get the unit exposed to vapor or oil steam. PROHIBITION Do not insert objects into the air inlet or outlet. Do not channel the air flow directly at people, especially at infants or the aged. PROHIBITION Do not try to repair or reconstruct by yourself. Connect the earth cable. earthing PROHIBITION CAUTION Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation. PROHIBITION Do not install the unit near a fireplace or other heating apparatus. Take fresh air occasionally especially when gas appliance is running at the same time. STRICT ENFORCEMENT Check good condition of the installation stand PROHIBITION Do not place animals or plants in the direct path of the air flow Do not operate the switch with wet hand. PROHIBITION Do not pour water onto the unit for cleaning PROHIBITION PROHIBITION Do not place any objects on or climb on the unit. PROHIBITION PROHIBITION Do not place flower vase or water containers on the top of the unit. PROHIBITION 50 Domestic air conditioner 2U14CS1ERA-SM Trouble shooting Cautions Before asking for service, check the following first. The system does not restart immediately. Noise is heard Normal Performance inspection Smells are generated. Mist or steam are blown out. Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver. Cause or check points Phenomenon Introduction When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard.At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard.This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes. Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit. Specifications The refrigerating circuit is leak-proof. The machine is adaptive in following situation 1.Applicable ambient temperature range: Indoor Cooling Maximum:D.B/W.B 32oC/23oC Minimum:D.B/W.B 21oC/15oC Maximum:D.B/W.B 46oC/26oC 18oC Maximum:D.B 27oC Minimum: D.B 15oC Outdoor Minimum: D.B Indoor Heating Outdoor Maximum:D.B/W.B 24oC/18oC Minimum:D.B/W.B - 7 oC/-8oC o o Outdoor Maximum:D.B/W.B 24 C/18 C (INVERTER) Minimum:D.B -15oC 2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3.If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air. 4. The wiring method should be in line with the local wiring standard. 5. After installation, the power plug should be easily reached. In dry mode, fan speed can’t be changed. In DRY mode, when room temperature becomes lower than temp. setting+2 oC,unit will run intermittently at LOW speed regardless of FAN setting. Poor cooling 7. The appliance is not intended for use by young children or infirm persons without supervision. 8. Young children should be supervised to ensure that they do not play with the appliance. Is power plug inserted? Is there a power failure? Is fuse blownout? Multiple check 6. The waste battery should be disposed properly. 9. Please employ the proper power plug, which fit into the power supply cord. Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation? 10. The power plug and connecting cable must have acquired the local attestation. 11.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power. Haier Group Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010 Website: www.haier.com 51 Domestic air conditioner 2U14CS1ERA-SM Service diagnosis 7.Service Diagnosis 7.1 Caution for Diagnosis The operation lamp flashes when any of the following errors is detected. 1.When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions, disabling equipment operation. 2.When a signal transmission error occurs between the indoor and outdoor units.In either case, conduct the diagnostic procedure described in the following pages. 7.2.Problem Symptoms and Measures SymptRm None of the units Check Item Check the power supply. Details of Measure Check to make sure that the rated voltage is supplied. operates Check the indoor PCB Check to make sure that the indoor PCB is broken Operation Check the power supply. A power failure of 2 to 10 cycles can stop air conditioner sometimes stops. operation. Check for faulty operation Set the units to cooling operation, and compare the of temperatures of the liquid side connection pipes of the the electronic Equipment operates but does expansion valve. not cool, or does not heat (only for heat pump) Diagnosis by service port connection section among rooms to check the opening and closing operation of the electronic expansion valves of the individual units. Check for insufficient gas. pressure and operating current. Large operating noise and vibrations Check the installation condition. Check to make sure that the required spaces for installation (specified in the Technical Guide, etc.) are provided. Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 7.4.Error Codes and Description indoor display Code indication Indoorand Outdoor Indoor Malfunction indoor Outdoor (LED1 flash times) E7 15 F3 4 F19 F4 F21 6 8 10 Communication fault between indoor and outdoor units Room temperature sensor failure Heat-exchange sensor failure Indoor EEPROM error Indoor fan motor malfunction Outdoor EEPROM error The protection of IPM Overcurrent protection of AC electricity for the outdoor model Communication fault between the IPM and outdoor PCB Power voltage is too high or low Overheat protection for exhaust temperature Frost-removing temperature sensor failure F6 12 Ambient temperature sensor failure Page .54 F25 13 Exhaust temperature sensor failure Page .54 F11 18 deviate from the normal for the compressor Page .66 F28 19 Loop of the station detect error Page .66 F2 24 Overcurrent of the compressor Page .59 F23 25 Overcurrent protection for single-phase of the compressor Page .59 E1 E2 E4 E14 F12 Outdoor Malfunction Reference Page Description F1 F22 1 2 3 Page .64 Page .54 Page .54 Page .55 Page .56 Page .55 Page .58 Page .59 Page .60 Page .61 Page .62 Page .54 53 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 7.4.1 Thermistor or Related Abnormality Indoor Display E1: Room temperature sensor failure E2: Heat-exchange sensor failure outdoor display Method of Malfunction Detection Malfunction Decision Conditions LED1 flash 10 times˖Frost-removing temperature sensor failure LED1 flash 11 times˖Suction temperature sensor failure LED1 flash 12 times˖Ambient temperature sensor failure LED1 flash 13 times˖Exhaust temperature sensor failure The temperatures detected by the thermistors are used to determine thermistor errors when the thermistor input is more than 4.92V or less than 0.08V during compressor operation. z Note: The values vary slightly in some models Supposed Causes Ŷ Faulty connector connection Ŷ Faulty thermistor Ŷ Faulty PCB Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. Check the connector onnection. NO Correct the connection Is it normal? Yes Thermistor resistance check NO Replace the thermistor Is it normal? Yes Replace the indoor unit PCB Thermistor resistance check method: Remove the connector of the thermistor on the PCB, and measure the resistance of thermistor using tester.The relationship between normal temperature and resistance is shown in the value of indoor thermistor. Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 7.4.2 EEPROM abnormal Indoor Display E4: indoor EEPROM error Indoor display F12: Outdoor EEPROM error ;Outdoor LED1 flash 1 times Method of The Data detected by the EEPROM are used to determine MCU Malfunction Detection Malfunction when the data of EEPROM is error or the EEPROM is damaged Decision Conditions Supposed Ƶ Faulty EEPROM data Causes Ƶ Faulty EEPROM Ƶ Faulty PCB Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Replace the indoor or outdoor mainboard 55 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 7.4.3 Indoor AC fan motor malfunction Indoor Display Method of Malfunction Detection Malfunction Decision Conditions E14 The rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor operation when the detected rotation feedback singal don’t receiced in 2 minutes Ƶ Operation halt due to breaking of wire inside the fan motor . Ƶ Fan motor overheat protection Ƶ Operation halt due to breaking of the fan motor lead wires Ƶ Detection error due to faulty indoor unit PCB Supposed Causes Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. Pull out the terminals on the indoor 1R Check whether terminals mainboard and reinsert them. on indoor pcb is well ? <HV Electrify the machine again and turn it on in the cooling operation, Measure voltage between the positions 1and 3 of Terminal CN2 on the indoor PCB the voltage is about 90-220vac 12 Yes Measure whether there is voltage pulse(0-5VDC) <HV check whether motor can run between the positions middle wire and black wire when turn on the unit of Terminal CN7 on the indoor PCB Is it ok? 12 12 <HV the indoor motor is damaged and need replace the indoor pcb is damaged and need replace 56 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 7.4.4 Outdoor DC fan motor fault Check whether Terminal on the outdoor mainboard is well inserted. NO Reinsert the terminals Is it normal? Yes Electrify the machine again and turn NO it on in the Cool state with the remote controller. check whether motor can run᧻ Measure the voltage between 1 and 3 of the terminal of fan motor on the mainboard about DC310V,Measure Yes the voltage between 3 and 4 of the terminal about DC15V. Measure the voltage between 5 and 3 of the Measure the voltage between 3 and 6 of terminal about 1-6v. the terminal about 0-5v. Yes Is it normal? Is it normal? Yes N0 N0 the motor of the outdoor unit is damaged The mainboard of the outdoor unit is and needs replacing. damaged and needs replacing 57 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 7.4.5 IPM protection Outdoor display Method of Malfunction Detection LED1 flash 2 times IPM protection is detected by checking the compressor running condition and so on Malfunction Decision Conditions Ƶ The system leads to IPM protection due to over current Ƶ The compressor faulty leads to IPM protection Ƶ circuit component of IPM is broken and led to IPM protection Supposed Causes Ƶ IPM protection dues to the compressor faulty Ƶ IPM protection dues to faulty PCB of IPM module ƵCompressor wiring disconnected Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, else parts damage may be occurred. or Electrify the machine again and turn it on <(6 with the remote controller,If malfunctions are reported before or upon IPM Module is damaged and the needs replacing. compressor being started up, Malfunction unsolved 12 The compressor is started normally, but malfunctions are reported after it has run for some time. 1ᇬThe system may have been over or under charged with gas, which can be judged through the pressure of the measuring system. 2ᇬThe shaft of compressor is seized and the compressor needs replacing. 58 Domestic Air Conditioner 2U14CS1ERA-SM Service diagnosis 7.4.6 Over-current of the compressor Outdoor Display LED1 flash 3 or 24 or 25 times Method of Malfunction Detection The current of the compressor is too high Malfunction Decision Conditions when the IPM Module is damaged or the compressor is damaged power supply. voltage is too low or too high Supposed Causes Troubleshooting Ŷ Faulty IPM Module Ŷ Faulty compressor Ƶ Faulty power supply * Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. 59 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM Electrify the machine again and turn it on YES with the remote controller,If malfunctions IPM Module is damaged and are needs replacing. reported before or upon the compressor being started up, NO The compressor is started normally, Yes but malfunctions are reported after it Repair the power supply has run for some time. Check the power supply is too low or too high NO NO the system may have been over or under charged with gas, which can be judged through the pressure of the measuring system. 7.4.7 The communication fault between IPM and outdoor PCB Outdoor display LED1 flash 4 times Method of Malfunction Detection Communication is detected by checking the IPM module and the outdoor PCB Malfunction Decision Conditions Ŷ The outdoor PCB broken leads to communication fault Ŷ The IPM module broken leads to communication fault Supposed Causes Ŷ The outdoor PCB is broken Ŷ The IPM module is broken Ƶ Communication wiring disconnected Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, else parts damage may be occurred. or 60 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 1) Check whether Terminal CN23 and CN24 on the outdoor mainboard CN10 and CN11 on IPM module 2) Check whether the connected wire between IPM and outdoor NO 1) Pull out and reinsert the terminals. 2) Replace connected wire Are they good? Malfunction unsolved YES Electrify the machine again and turn it on, Check whether the voltage between YES 1 and 2 of Terminal CN23 is about Replace the outdoor IPM module DC5V, with a new one. Check whether the voltage between2 and 3 of Terminal CN23 is about DC15V, NO Replace the outdoor mainboard with a new one 7.4.8 Power Supply Over or under voltagve fault outdoor display: Method of Malfunction Detection Malfunction Decision Conditions Supposed Causes LED1 flash 6 times The power supply is over voltage An abnormal voltage rise or fall is detected by checking the specified voltage detection circuit. An voltage signal is fed from the voltage detection circuit to the microcomputer Ŷ Supply voltage not as specified Ŷ the IPM module is broken Ƶ the outdoor PCB is broken 61 'RPHVWLF $LU &RQGLWLRQHU Service diagnosis 2U14CS1ERA-SM Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. Electrify the machine again and turn it on with the remote controller. Check whether the compressor is started normally Yes Maybe there is some disturbance Is it ok? No Yes Test the outdoor power supply Change the IPM module (+310VDC) with a multimeter. check whether the power is >150 V or <390V? NO Yes Change the IPM module ~220 is ok? NO This question may be caused by the power.Repair the power supply. 7.4.9 Overheat Protection For Exhaust Temperature outdoor display Method of Malfunction Detection Malfunction Decision Conditions Supposed Causes Troubleshooting LED1 flash 8 times The exhaust temperature control is checked with the temperature being detected by the exhaust pipe thermistor when the compressor discharge temperature is above 110ć Ŷ Electronic expansion valve defective Ŷ Faulty thermistor Ƶ Faulty PCB * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. 62 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM Electrify the machine again and turn it on with the remote controller, then measure the temperature at the exhaust temperature sensor of the compressor on the outdoor unit 1) The cryogen may have been leaked during the temperature 110ć shortly YES exceeds after installation, or there may be leakage in the piping system. the 2) There may be other causes to make the exhaust machine starts up? temperature too high. NO Malfunctions occur after running for some time even though the measured temperature is below 110ć. Pull out the exhaust sensor and measure its resistance at standard temperatures according to the resistance-temperature table YES the results The sensor is damaged. Replace the sensor deviate with a new one. much? NO The outdoor mainboard is damaged and needs be replaced 63 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 7.4.10 The communication fault between indoor and outdoor Indoor display outdoor display E7 LED1 flash 15 times Method of Malfunction Detection Communication is detected by checking the indoor PCB and the outdoor PCB Malfunction Decision Conditions Ŷ The outdoor PCB broken leads to communication fault Ŷ The indoor PCB broken leads to communication fault Supposed Causes Troubleshooting Ŷ Ŷ Ƶ Ƶ Communication wiring disconnected The indoor PCB is broken The outdoor PCB is broken The Module PCB is broken * Caution Be sure to turn off power switch before connect or disconnect connector, else parts damage may be occurred. Restart the a/c and it Yes or The outdoor mainboard needs dehumidification. becomes normally. NO If starting up normally, but NO The outdoor mainboard needs malfunction occurs again after a dedust. while YES Check whether the linking cable No 1. Reconnect the linking cable; between the indoor and outdoor is well 2. Replace the linking cable with new connected or whether its core wires are one. well insulated. Yes ˄A˅ 64 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM ˄A˅ Check the status of LED1 on the Yes indoor mainboard. If the LED1 blinks interruptedly˛ measure the voltage between Jumpers 3 and 4 of IC1 on the indoor mainboard with a No multimeter. Test the outdoor power supply (230VAC and +310VDC) with a multimeter. If the voltage is of a constant value of 0V DCto5V DC If 230VAC is available but 310DC not, the power module is damaged, replace it with a new one. YES If both 230VAC and 310DC are NO The indoor mainboard is damaged; replace available,measure +12V(from7805) NO it with a new one. is available. The outdoor mainboard is damaged; Replace them with a new one. YES If the LED1 is off within two minutes after the machine is supplied with power, measure the If the value is constant at about 30V, the AC voltage between positions 1 and 3 on the indoor mainboard is damaged, replace it with terminal of outdoor unit with a multimeter. a new one. If the value varies between 0 and 80 VAC, the The outdoor mainboard is damaged; replace outdoor mainboard is damaged, replace it it with a new one. with a new one. 65 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 7.4.11 Loss of synchronism detection Inverter side current detection is abnoraml Outdoor Display LED1 flash 18 times LED1 flash 19 times Method of Malfunction Detection The position of the compressor rotor can not detected normally Malfunction Decision Conditions when the wiring of compressor is wrong or the connection is poor; or the compressor is damaged Ŷ Faulty The wiring of compressor Ŷ Faulty compressor Ƶ Faulty PCB Supposed Causes Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Within 3 minutes after the machine is supplied with power and turned on with the remote controller,check whether the compressor can stard up NO 1. The wiring of compressor is incorrect or the connection is poor; 2. The compressor is damaged YES At frist, the compressor start up ,soon the compressor stopped with the LED1 on the outdoor PCB blinks˄1Hz˅19/18 times YES IPM Module is damaged and needs replacing. Malfunction unsolved the Maybe there is some disturbance Malfunctions exist also, the compressor is damaged replace a new one 66 Domestic Air Conditioner Service diagnosis 2U14CS1ERA-SM 7.4.12 High work-intense protection Outdoor display LED1 flash 21 times Method of Malfunction Detection High work-intense control is activated in the heating mode if the temperature being sensed by the heat exchanger thermistor exceeds the limit. Malfunction Decision Conditions Activated when the temperature being sensed by the heat exchanger rises above 65ć twices in 30 minutes. Ŷ Ŷ Ƶ Ƶ Supposed Causes Troubleshooting Faulty electronic expansion valve Dirty heat exchanger Faulty heat-exchange sensor Insufficient gas * Caution Be sure to turn off power switch before connect or disconnect connector, else parts damage may be occurred. or Electrify the machine again and turn it on with the remote controller, check whether the wind temperature is below 65ć YES the malfunction is reported after the machine has run for some time? 1 ǃ Check room temperature and pipe temperature sensor. 2ǃthe temperature monitoring circuit of the indoor mainboard NO YES the indoor unit blows poorly due to blocked filters or poor condition of the fan? 1) Clean the filters 2) Reinstall the fan. NO Use some tools to measure the pressure of systemˈ 67 Domestic Air Conditioner Installation 2U14CS1ERA-SM 8 Installation EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS IMPORTANT INFORMATION REGASelection of Installation Place RDING THE REFRIGERANT USED Contains fluorinated greenhouse gases covered by the Kyoto Protocol CE All the products are in conformity with the following European provision: - Low Voltage Directive 73/23/EEC - Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC R410A 1= kg 2 2= kg 1+2= kg 1 ROHS F The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive) WEEE In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products. DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol.This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself : the dismantling of the air conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and nationl legislation. A B C D E This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere. Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink, •1 the factory refrigerant charge of the product •2 the additional refrigerant amount charged in the field and • 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging 68 Domestic air conditioner 2U14CS1ERA-SM Installation The models adopt HFC free refrigerant R410A. For installation of the indoor units,refer to the installation manual which was provided with the units. (The diagram shows a wall-mounted indoor unit.) Attention must be paid to the rising up of drain hose more than 15 cm Optional parts for piping Indoor unit A A Non-adhesive tape B Adhesive tape more than10cm more than 10cm Indoor unit B C Saddle (L.S) with screws Connecting electric cable D for indoor and outdoor E Drain hose F F Heating insulating material G Piping hole cover C Arrangement of piping directions more than 0cm Rear left Rear right Left Fixing of outdoor unit ƽ Fix the unit to concrete or block Right Below ƽ The marks from A to G in the figure are the parts numbers. ƽ The distance between the indoor unit and the floor should be more than 2m. D more than 0cm ƽ E with bolts (10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind. ƽ If vibration may affect the more than 60cm more than 5cm house, fix the unit by attaching a vibration-proof mat. AIR OUTLET AIR INLET CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE 4 Compressor(Inside of Unit) ƽ The above indoor and outdoor units’ picture is just for your reference. Please be subject to the actual product purchased. 69 Domestic air conditioner 2U14CS1ERA-SM Installation WARNING CAUTION 70 Domestic air conditioner 2U14CS1ERA-SM Installation 71 Domestic air conditioner Safety Precautions 2U14CS1ERA-SM Installation Precautions for Handling Units for Use with R410A Caution Do not use the existing refrigerant piping Use a vacuum pump with a reverse-flow check valve. If other types of valves are used, the vacuum pump oil will The old refrigerant and refrigerator oil in the existing piping flow back into the refrigerant cycle and cause the refrigerator contain a large amount of chlorine, which will cause the oil to deteriorate. refrigerator oil in the new unit to deteriorate. R410A is a high-pressure refrigerant, and the use of the Do not use the following tools that have been used with the existing piping may result in bursting. conventional refrigerants. Prepare tools that are for exclusive use with R410A. (Gauge manifold, charging hose, gas leak detector, reverse-flow check valve, refrigerant charge base,vacuum gauge, and refrigerant recovery equipment.) If refrigerant and/or refrigerant oil left on these tools are Keep the inner and outer surfaces of the pipes clean and mixed in with R410, or if water is mixed with R410A, it will free of contaminants such as sulfur, oxides, dust/dirt shaving cause the refrigerant to deteriorate. particles,oils,and moisture. Since R410A does not contain chlorine, gas-leak detectors Contaminants inside the refrigerant piping will cause the for conventional refrigerators will not work. refrigerant oil to deteriorate. Caution Store the piping to be used during installation indoors, and Do not use a charging cylinder. keep both ends of the piping sealed until immediately before The use of charging cylinder will change the composition brazing.(keep elbows and other joints wrapped in plastic.) of the refrigerant and lead to power loss. If dust, dirt, or water enters the refrigerant cycle, it may cause the oil in the unit to deteriorate or may cause the compressor to malfunction. Exercise special care when handling the tools. An introduction of foreign objects such as dust, dirt or Use a small amount of ester oil, ether oil, or alkylbenzene water into the refrigerant cycle will cause the refrigerating to coat flares and flange connections. machine oil to deteriorate. A large amount of mineral oil will cause the refrigerating machine oil to deteriorate. Use liquid refrigerant to charge the system. Charge the unit with gas refrigerant will cause the refrigerant Only use R410A refrigerant. in the cylinder to change its composition and will lead to The use of refrigerants containing chlorine(i.e. R22) will a drop in performance cause the refrigerant to deteriorate. Before Installing the Unit Caution Do not install the unit in a place where there is a possibility When installing the unit in a hospital, take necessary measures of flammable gas leak. against noise. Leaked gas accumulated around the unit may start a fire. High-frequency medical equipment may interfere with the normal operation of the air conditioning unit or the air Do not use the unit to preserve food, animals, plants, artifacts, conditioning unit may interfere with the normal operation or for other special purposes. of the medical equipment The unit is not designed to provide adepuate conditions to preserve the quality of these items. Do not use the unit in an unusual environment The use of the unit in the presence of a large amount of oil, steam, acid, alkaline solvents or special types of sprays Do not place the unit on or over things that may not get wet. may lead to a remarkable drop in performance and/or When humidity level exceeds 80% or when the drainage malfunction and presents a risk of electric shock, smoke, system is clogged, indoor units may drip water. or fire. Installation of a centralized drainage system for the outdoor The presence of organic solvents, corroded gas (such as unit may also need to be considered to prevent water drips ammonia,sulfur compounds,and acid may cause gas or from the outdoor units. water leak.) 72 Domestic air conditioner Safety Precautions 2U14CS1ERA-SM Installation Before Installing (Relocating) the Unit or Performing Electric Work Caution Ground the unit. Do not connect the grounding on the unit to gas pipes,water pipes, lightning rods, or the grounding terminals of telephones. Improper grounding presents a risk of electric shock, smoke, fire, or the noise caused by improper grounding may cause the unit to malfunction. Do not spray water on the air conditioners or immerse the air conditioners in water. Water on the unit presents a risk of electric shock. Periodically check the platform on which is placed for damage to prevent the unit from falling. If the unit is left on a damaged plarform, it may topple over, causing injury. Make sure the wires are not subject to tension. If the wires are too taut, they may break or generate heat When installing draining pipes, follow the instructions in the and/or smoke and cause fire. manual, and make sure that they properly drain water so as Install a breaker for current leakage at the power source to avoid dew condensation. to avoid the risk of electric shock. If not installed properly, they may cause water leaks and Without a breaker for current leakage, there is a risk of damage the furnishings. electric shock, smoke or fire. Properly dispose of the packing materials. Use breakers and fuses (electrical current breaker, remote Things such as nails may be included in the package. switch<switch+Type-B fuse>,molded case circuit breaker) Dispose of them properly to prevent injury. with a proper current capacity. Plastic bags present a choking hazard to children. Tear up the plastic bags before disposing of them to prevent The use of large-capacity fuses, steel wire, or copper wire accidents. may damage the unit or cause smoke or fire. Before the Test Run Caution Do not operate switches with wet hands to avoid electric. Do not touch the refrigerant pipes with bare hands during and immediately after operation. Depending on the state of the refrigerant in the system, certain parts of the unit such as the pipes and compressor may become very cold or hot and may subject the person to frost bites or burning. Do not operated the unit without panels and safety guards in their proper places. They are there to keep the users from injury from accidentally touching rotating, high-tempreture or highvoltage parts. Do not turn off the power immediately after stopping the unit. Allow for at least five minutes before turning off the unit, otherwise the unit may leak water or experience other problems. Do not operate the unit without air filters. Dust particles in the air may clog the system and cause malfunction. 73 Domestic air conditioner 2U14CS1ERA-SM Installation 74 Domestic air conditioner 2U14CS1ERA-SM Installation 75 Domestic air conditioner 2U14CS1ERA-SM Installation 76 Domestic air conditioner 2U14CS1ERA-SM Installation NO Air outlet Wind direction Cushion rubber 4.Installation dimension(Unit:mm) 77 Domestic air conditioner 2U14CS1ERA-SM Installation 1. 2U14CS1ERA 2U18FS1ERA 2. Connection of pipes ● ● ● To bend a pipe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer. Connecting the pipe of gas side first makes working easier. The connection pipe is specialized for R410A. Half union Spanner Forced fastening without careful centering may damage the threads and cause a leakage of gas. Flare nut Pipe Diameter(ǿ) Fastening torque Liquid side6.35mm(1/4") 18N.m Liquid/Gas side9.52mm(3/8") 42 N.m Torque wrench Gas side 12.7mm(1/2") 55N.m Gas side 15.88mm(5/8") 60 N.m Be careful that matters, such as wastes of sands,water,, etc. shall not enter the pipe. CAUTION: Be careful that matters, such as wastes of sands, etc. shall not enter the pipe. The standard pipe length of each indoor unit is 5m. If total pipe length is over 20m, the function of the unit will be affected, charge more refrigerant is needed, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge additional refrigerant. CAUTION Indoor unit Indoor unit B1 B1 B1 Indoor unit A1 B2 Indoor unit Outdoor unit A1 A2 A3 A2 Indoor unit B2 Outdoor unit Outdoor unit Indoor unit B2 Indoor unit Outdoor unit B Oil trap Indoor unit Max.Elevation: A1 max =15m A2 max =15m A3 max =15m In case the elevation B is more than 5m, oil trap shoud be installed every 5~7m Max. Length: B1 max =20m B2 max =20m (B1+B2) max =30m In case the pipe total length (B1+B2) is more than 20m, the refrigerant should be charged, according to 20 g/m. 78 Domestic air conditioner 2U14CS1ERA-SM Installation 79 Domestic air conditioner 2U14CS1ERA-SM Installation 2-way valve 3-way valve 2-way valve 3-way valve 2-way valve 3-way valve 2-way valve 3-way valve ƽ ƽ Each indoor unit musts to be vacuumed , according to the above steps. ƽ If the refrigerant of the air conditioner leaks, it is necessary to discharge all the refrigerant. Vacuumize first, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate. ƽ Please do not let other cooling medium, except specified one (R410A), or air enter into the cooling circulation system. Otherwise, there will be abnormal high pressure in the system to make it crack and lead to personal injuries. 80 Domestic air conditioner 2U14CS1ERA-SM Installation 2U14CS1ERA 2U18FS1ERA T 25A/250V. 14K 18K Outdoor unit A To Indoor unit A Outdoor unit A To Indoor unit A 2U14CS1ERA 2U18FS1ERA Model Outdoor unit B 1(N) 2(L) 3(C) To Indoor unit B 1(N) 2(L) 3(C) ^ POWER Outdoor unit B Connecting wiring To Indoor unit B Power cable DOUBLE 4G0.75mm 2 DOUBLE 3G2.5mm2 ^ POWER 81 Domestic air conditioner 2U14CS1ERA-SM Installation Outdoor Unit Troubleshooting 1 2 4 15 5 6 8 110 9 10 11 Suction temperature sensor failure When the The wiring of compressor is wrong or the connection is poor 12 13 15 16 Check if there is leakage in the unit. Lack of refrigerant m 15 17 18 19 25 25 25 Haier Group Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010 Website: www.haier.com 82 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 83 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 2 Please embed the air filters into the unit along the grooves as installation. Please embed the two hooks on air filter completely into the unit during installation. 84 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure Removal of Front Panel Open the front panel until it is on the horizontal position, and then release the pivots on both sides of the unit to remove the front panel. Please close the panels before start the removal procedure of front grille. Slide the front panel from one side to another to release each axis. 85 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure two HOOKS three 86 Domestic air conditioner 2U14CS1ERA-SM 3 Removal of procedure horizontal flap flap flap flap flap 87 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 4 5HPRYDORI'UDLQSDQ 3URFHGXUH :DUQLQJ 6WHS %HVXUHWRZDLWPLQXWHVRUPRUHDIWHUWXUQLQJRIIDOOSRZHUVXSSOLHV EHIRUHGLVDVVHPEOLQJZRUN 3URFHGXUH 3RLQWV 5HPRYHWKH'UDLQSDQ /RRVHQWKHPDUNHG VFUHZVXQGHUWKH VFUHZFRYHUV /LIWXSWKHORZHUSDUWRI WKHJULOOHWRUHOHDVHWKH KRRNRQWKHXSSHU EDFNVLGH 5RWDWHWKHXSSHUSDUWRI WKHJULOOHWRUHOHDVHWKH KRRNRQWKHORZHUEDFN VLGH 3XOORXWWKH GUDLQSDQ 88 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 5 5HPRYDORI9HUWLFDO%ODGHVDQG6ZLQJ0RWRU 3URFHGXUH :DUQLQJ %HVXUHWRZDLWPLQXWHVRUPRUHDIWHUWXUQLQJRIIDOOSRZHUVXSSOLHV EHIRUHGLVDVVHPEOLQJZRUN 3URFHGXUH 6WHS 3RLQWV 5HPRYHWKHDVVHPEO\RI WKHRXWOHWJULOOH 5HPRYHWKHYHUWLFDO EODGHV 3XVKWKHKRRNVRQWKH EDFNRIWKHYHUWLFDOEODGHV DQGUHPRYH 89 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 6 5HPRYDORI(OHFWULFDO%R[ 3URFHGXUH :DUQLQJ %HVXUHWRZDLWPLQXWHVRUPRUHDIWHUWXUQLQJRIIDOOSRZHUVXSSOLHV EHIRUHGLVDVVHPEOLQJZRUN 3URFHGXUH 6WHS 3RLQWV 5HPRYHWKHIURQWJULOOH 5HPRYHWKHHOHFWULFDO ER[ /RRVHQWKHVFUHZRIWKH GULSSURRISODWH /LIWDQGUHPRYHWKH HOHFWULFDOER[ 'LVFKDUJHWKHVWDWLF HOHFWULFLW\IURP\RXUERG\ EHIRUHWRXFKLQJWKHHOHFWULFDO SDUWVOLNHVLJQDOUHFHLYHU 3&% ,WPD\FDXVHPDOIXQFWLRQRI 3&% :KHQDVVHPEOLQJLQVHUWWKH OHIWKRRNRIWKHGULSSURRI SODWHLQWRWKHKHPSODWHRI WKHKHDWH[FKDQJHU 90 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure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omestic air conditioner 2U14CS1ERA-SM 3URFHGXUH 6WHS Removal of procedure 3RLQWV 5HOHDVHWKH KRRNV 5HOHDVHWKHKRRNIURP WKHEDFNVLGH /LIWXSWKHORZHUSDUWRI WKHIL[WXUHSODWHDQG UHPRYHLW 5HPRYHWKHKHDW H[FKDQJHU 77 92 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 8 Domestic air conditioner 2U14CS1ERA-SM 3URFHGXUH 6WHS Removal of procedure 3RLQWV 5HPRYHWKHIDQ /RRVHQWKHPDUNHG VFUHZ /LIWXSWKHULJKWSDUWRI WKHIDQ PRWRU DQGVOLGH LW WRWKHULJKWZDUGWR UHPRYH Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 9 Domestic air conditioner 2U14CS1ERA-SM 1 Loosen the top panel screws 2 Lift the top panel Removal of procedure Domestic air conditioner 2U14CS1ERA-SM Removal of procedure Loosen the csrews and pull the panel Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 2 Pull the wind circle Remove the inlet grill Push the hooks first Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 10 99 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 11 Domestic air conditioner 2U14CS1ERA-SM 2 Removal of procedure Loosen the fixing screws and remove the motor 101 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 12 102 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure Loosen the screw and remove the reactor 103 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure 13 Loosen the marked screws and pull out the backgurd 104 Domestic air conditioner 2U14CS1ERA-SM 2 3 Removal of procedure Loosen the marked screws and remove the stop valves Loosen the marked screws and remove the stop valves bracket 105 Domestic air conditioner 2U14CS1ERA-SM Removal of procedure Loosen the screw and remove the reactor 106 Domestic air conditioner 2U14CS1ERA-SM 10. Appendix 10.1 Piping Diagrams 107 $SSHQGL[ 2U14CS1ERA-SM 10.2 Wring Diagram Wiring Diagrams Indoor 108 Domestic air conditioner Wring Diagram 2U14CS1ERA-SM Outdoor 287'225:,5,1*',$*5$0 *1' 3 8 &1 : 02'8/(&20 % 0$,13&%%2$5' %/ &2035(6625 &20% &1 &20$ 1 &1 02'8/(32:(5 : 3)&5($&725 5869 &: 5 : 3( <*˖<(//2: *5((1 &1 '&)$1 &1 &1 0 &1 &1 &1 &1 +: &6 &15 &1 9$/9(% 7& &1 $&1287 &1: 9$/9($ &1 &1 &1 $ $ &*$ ;*$ 3,3( 7(036(1625 &1 $&/287 % &*% % ;*% '()5267 7(036(1625 $0%,(17 7(036(1625 3,3( 7(036(1625 % $ $&)$102725 (/(&75,&(;3$16,219$/9( &2035(6625',6&+$5*( 7(036(1625 0 &1 32:(5 *1' '&)$102725 %5˖%52:1 %˖%/$&. 5˖5(' 25˖25$1*( %/˖%/8( :˖:+,7( <(/˖<(//2: % 1 / 3 &1 % 5 72,1'22581,7$ 72,1'22581,7% 9 : % % &1 &1 : : % %5 % &1 1 &1 : &1 / &1 25 $&1 : % 7(50,1$/ : % 5 %/2&. $ $&/ : /, %5 : 1 %/ &1 &1 02'8/(%2$5' &1 &1 &1 )86( 9$ &1 $&/ %/ &1 &1 $&1 % 3 0 $&)$102725 :$<9$/9( DON'T TOUCH CAPACITOR, EVEN AFTER PLUG-OFF ( DANGER OF ELECTRIC SHOCK) THE CAPACITOR RETAINS HIGH VOLTAGE EVEN AFTER THE PLUG-OFF.FOR YOUR SAFETY,BE SURE TO WAIT AT LEAST 5 MINUTES.AFTER PLUG OFF AND USE A TESTER TO CONFIRM THE VOLTAGE BETWEEN CONNECTOR &1 AND &1(ON MAIN PCB BOARD) IS LESS THAN DC 10V BEFORE START SERVICING OR LED2 EXTINGUISHED. R em arks ˖ 1 .the d o tte d pa rts a re op tion a l fo r d iffe re n t u n it. 2.T he com ponents of m ain pcb board is fixed facin g to the com presso r . 109 Domestic air conditioner 2U14CS1ERA-SM Wring Diagram 10.3 CIRCUIT DIAGRAM indoor unit +5V SW1 TSVC-1 R45 10K R46 1K +5v CN6 SW1-1 JTP1288LA R55 R59 R62 R63 C25 0.1UF +5V R301 10K REV SCK RCK SER GND +5V COM2 COM3 1K 100ȍ 100ȍ 100ȍ R65 100ȍ R66 100ȍ C10 R2 R4 2K 10K IC1 R40 0.1UF P1 2SA1037AK R1 10K R61 +5V C27 0.001uF IRQ C5 E5 1 2 +5V 10K TXD RXD ZERO CN5 TJC8-02 0.1UF 100uF-16V R20 CN7 51K 3 2 1 R58 C16 0.001UF 1K C15 B3B-EH-A JSS1270 R43 3.3K E2 +5V SW2 10K R9 R11 1M N5 2SC2412 JSS1270 1 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 PTE4/OSC1 PTE3/OSC2 PTE2 VSSA VDDA PTA7/KBD7 PTA6/KBD6 PTA5/KBD5 PTA4/KBD4 PTA3/KBD3 PTA2/KBD2 PTA1/KBD1 PTA0/KBD0 VREFL VREFH PTB7/AD7 PTB6/AD6 PTB5/AD5 PTB4/AD4 PTB3/AD3 PTB2/AD2 PTB1/AD1 OSC1 OSC2 GND +5V E2 SCL E2 SDA R110 10K IC4 ULN2003 16 15 14 13 12 11 10 9 +12V 10K2 10K3 1K4 5 1K6 1K7 8 R57 R56 +5V DATA C20 +5V R28 1K B3P5-VH R33 R32 R31 R34 10K 10K 10K 10K R36 1K C12 0.1UF MC908GT16CFBE CN12 TLP3526 C13 0.01uf-50V 0.01UF 4.7uF-16V E2 E3 4.7uF-16V CN8 R38 R37 1K C14 R27 0.01UF 4.7K 1% 4 3 2 1 4.7K 1% S4B-XH-A BUZZ1 BEEP-PKM13EPY-4002 N L0 +12v +5V R35 1K R303 10K +12V IC8 1 2 TJC8-02 0.001UF C23 R67 680ȍ L0 MKP61-103-275V L1 +5V 10K 5 4 3 2 1 0.1UF R47 171uH-800mA-1KHZ -LHB1308-171 CN10 TJC8-02 CN9-1 +12v C19 CBB61-1.2uf-450VAC R64 120ȍ-1W C22 3 2 1 +5V S5B-PH N CN2 GND +5V B2B-XH-A N4 2SC2412 R18 4.7K A R30 R25 R26 CN13 1 2 R21 27ȍ 10K B FCR8.0MC5 10K 10K R23 25 +5V SW3 R29 3.3K TJC8-02 RESET PTC0 PTC1 PTC2 PTC3 PTC4 PTC5 PTC6 PTE0/TXD PTE1/RXD IRQ PTD0/SS PTD1/MISO PTD2/MOSI PTD3/SPSCK VSS VDD PTD4/T1CH0 PTD5/T1CH1 PTD6/T2CH0 PTD7/T2CH1 PTB0/AD0 +12V R22 0.01UF 35 1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 595 SER 595 RCK 14 595 SCK 15 16 GND 17 +5V PG Feedback 18 PG output 19 20 21 22 10K +5V R19 R53 10K 2 1 XT1 R12 10K 560ȍ XT1 CN11 C18 0.1UF 2K C2 AT24C02B 8 7 6 5 3 R3 R10 A0 VCC A1 TEST A2 SCL VSS SDA 2 +5V +5V 1 2 3 4 B8B-PH R302 10K 0.01UF 8 7 6 5 4 3 2 1 R68 10K C9 IC7 1 +5V R16 1K C7 0.1UF CON2 D8 RLS4148 R60 4.7K (L_IN) 1 K2 892N-1AC-C CON1 FLZ 1 +12V R24 R48 220ȍ N7 2K 2SC2412 R71 10K R108 R104 100K-1/4W +5V IC101 1K 1N4007 ZD101 1N4746A(18V-1W) C102 0.047uF-50V R101 TXD 47K-2W R106 D101 L 47K-2W PC851 +5V N E101 100uF-50V R102 2K IC102 R103 RXD C101 0.001uF CON6 C103 2.2nf-250VAC 1K 1 R105 4.7K-1/4w TLP421 S(N-W) N CN3 1 2 3 5289-2A 1 D102 R107 1N4007 2K-2W CON7 COM +5V +5V R17 R14 10K N2 2SC2412 L 1 1 CON3 L0 FUSE1 T3.15A-250V AC R15 2 1 10K R13 4.7K 1K R201 2K C8 0.01UF NERTB-1.5-2P RV1 S14K350 R202 4.7K N3 2SC2412 C17 0.001UF C3 2 N CN1 R39 ZERO 4.7K CN4 N MKP61-104-275V B3B-XH-A +12V D5 D3 1N4007 D4 1N4007 D2 1N4007 D1 1N4007 IC3 1 1N4007 C1 E1 2200uF-35V MC7805CT +5V 3 2 3 2 1 0.1UF E4 470uF-16V C4 0.1UF 110 Domestic air conditioner 2U14CS1ERA-SM Wring Diagram AC-L AC-N 472/250V/275V 1K C28 C27 C29 104/50V ERROR 104/50V R36 2K VO IC14 T600D D11 RLS4148 CN35 R35 10K IC6 5 6 7 R60 8 10K D1 3 D5 IN4937\ER106 +12V 1 3 J8 4 R16 104/50V 1K/0.5W NC CS VCC 1 16 2 15 14 3 4 13 12 5 6 11 10 7 GND12V IC16 PC817A 3 1 R23 47 E5 470U/25V R11 47 R8 330/1W 5 4 5 E8 100U/16V 220 220 CX7 CN37 CY12 4 E4 470U/25V CN23 1 2 3 1 1 105/275VAC CN31 3 IC12 4 1K R39 IC11 IC2 PC817A 1 2 R26 1K R25 1K C5 104/50V IC3 TL431C R5 1.8K CN28 4 CN4 CY8 222/250V D9 IN4007 3 IC10 4 TLP421/PS2561 2K R43 IC9 1 2 N E2 CN26 820U/400V N E1 CN25 820U/400V N 1 CN5 3 1 1 P 1 R3 CN36 2K/2W COMB 2 4 CN27 1 CY7 222/250V COMA 1 J65 1K R42 CN30 820U/400V 2 N 3 E3 1 P 1 TLP851/PC851 C15 102/50V R41 N 1 1 J64 2 CN32 105/275VAC 1 CN29 R27 5.1K/1% TLP421/PS2561 1 CX6 1 P R12 330/1W C6 104/50V 3 2/1W 2K R40 CN38 1 222/250VAC +15V IRFUC20 1K 1 R83 330 C9 104/50V D6 MUR115\ER106 E9 47U/25V M1 TXD2 TXD1 ZD3 5.1V/0.5W 2 3 Vout E6 100U/16V C2 102/100V 6 15 1K +5V CN22 310V 1 2 0V 3 15V 4 5 6 R82 1K CN39 7 NCP1200P100 R20 C14 102/50V R38 RXD1 CX8 104/275V 10V/0.5W ZD2 3 P +5V 5 4 3 2 1 1 4 R81 C31 2.2K103/50V E11 47U/25V +5V L7805CV R14 L3 20UH/1A 1 HV 20K/1% RXD2 CN43 3 2 1 9 8 7 6 5 4 3 2 1 PC817A 2 1K N1 8050 R13 7 FB Vin 8 GND DRV R22 1K R21 J20 R80 1K R84 1K +5VD IC1 ADJ IC4 C8 D7 6 MBR1100 2 CN41 CN40 CN42 R85 3 R24 5.1K/1% R10 100K/2W CY11 472/1KV 5.1K/1% C4 103/50V R9 C3 102/100V D8 10 MBR3100\ER302 E7 470U/25V 9 1 1 C10 102/50V C21 104/50V GND 47 E22034 T1 R19 R92 0 10K IC15 1 J60 R15 CX5 104/275V 10K R79 R30 1K AC-L AC-N NTC1 SCK-4R72 R18 +5V CN24 5V 3 COM 2 GND 1 R29 10K 2 D2 ZD1 IN5948B CN34 C22 104/50V +5V R28 5.1K/1% P1 2SA1037AK 330 J45 J55 J21 R77 5.1K/1% 4 3 2 1 GND GND GND GND 2 IN4007 IN4007 IN4007 IN4007 E10 47U/450V LED1 AT24C04 SDA SCL GND VCC 1 D3 +5V 1 2 3 4 5 1 2 R78 J17 R62 560 J18 J54 J46 10K VCC R61 4 3 2 1 XT1 4M GND R91 0 +5V E12 +5V 104/50V 4.7U/16V C13 C12 104/50V R59 10K /1% C20 102/50V 1 2 1K R58 10K /1% C19 102/50V R89 CN4510K C11 102/50V 4 1K R88 CN15 C18 104/50V 10K CN44 TEST/SS CN16 6 5 A1 4 B1 3 C1 2 D1 1 +12V IC7 ULN2003 R87 J53 1K R64 CN33 C16 GND 104/50V 1 5V 2 +5V RST J29 3 R37 MODE 10K 4 J28 FLASH +12V 32 J11 J14 31 30 +12V 29 28 27 J61 26 25 24 23 22 21 20 19 18 17 C17 104/50V 1 16 R56 1K 2 15 R55 1K 3 14 R54 13 1K 4 R53 1K 5 12 R52 1K 11 6 R51 1K 7 10 GND12V NC NC NC NC NC ഫ䗮䆃TXD0 ഫ䗮䆃RXD0 NC HEAT-EN COOL-EN IC17 TEST-EN R5F212A8SNFA NC NC NC 㝼㚔䯔A2 㝼㚔䯔B2 1 2 3 4 5 6 7 8 9 10 11 12 J47 13 14 15 16 1K R66 +5V +5V C26 C25 C24 R68 4.7U/16V E13 D4 C30 104/50V104/50V104/50V 104/50V 4.7U/16V E14 47K /1% 104/50V E15 4.7U/16V +12V 6 5 A2 4 B2 3 C2 2 D2 1 FUCTION TEST C23 104/50V R71 C C 2U/450V C1 K1 +12V IC8 ULN2003 1K 1K 1K 48 47 46 45 44 43 42 41 40 39 38 37 36 J51 35 J52 34 33 MC14052 R70 1K Ӵᛳ఼ 4052-A CG HW CS XG TC NC NC 乥⥛䇗㡖 䯔ǃ亢ᴎ䇗㡖 VSS/AVSS ⬉⑤ࠊ VREF VCC ッᄤᥦ䖛⏽Ẕ⌟ PTC 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 J42 E16 4.7U/16V E17 4.7U/16V +5V J3 K2 J37 R50 J36 R44 J35 R45 1K +5V J9 J10 J16 J38 J41 J44 J56 㝼㚔 䯔D1 Ӵᛳ఼4052- B 㝼㚔 䯔C1 VSS MODE VSS 㝼㚔 䯔B1 亢ᴎ ᓔ݇ 㝼㚔 䯔A1 ಯ䗮 䯔 RESET ϝ䗳 亢ᴎ 催亢 XOUT ϝ䗳 亢ᴎЁ/Ԣ亢 ˄ঠ䗳 亢ᴎ催/Ԣ亢 ˅ VSS/AVSS ᅸ ݙᴎ䗮 䆃TXD2 XI N NC VCC/AVCC ᅸ ݙᴎ䗮䆃4052- A SDA ᅸ ݙᴎ䗮 䆃RXD1 SCL PC䗮䆃 TXD1 Ⳉ⌕ 亢ᴎ 䇗䗳 Ⳉ⌕ 亢ᴎ ড作 㝼㚔 䯔D2 ᅸ ݙᴎ䗮䆃4052- B 㝼㚔 䯔C2 NC ᬙ䱰 ♃ NC J13 R75 CN17 3 5V 2 TC 1 IC5 H 0 J48 Y0 VDD Y2 X2 Y X1 Y3 X Y1 X0 INH X3 VEE A VSS B J62 SW TEST CN18 5V 2 CS 1 1K R67 R69 20K /1% 20K /1% R72 20K /1% 20K /1% R65R63 CN19 5V 3 2 HW 1 E18 4.7U/16V E19 4.7U/16V R76 20K/1% R74 J63 R93 0 R73 20K/1% L K3 J22 J23 J25 J24 R90 J49 J39 MC14052 +5V CN21 XG-A 4 5V 3 5V 2 CG-A 1 CN14 CN13 COM J12 J15 J27 J30 J40 J43 J57 J59 PE J31 J32 J34 J33 Y0 VDD Y2 X2 Y X1 Y3 X Y1 X0 INH X3 VEE A VSS B J66 K5 J58 R86 0 +5V COM 12V-5A-892-1CC-C 12V-5A-892-1CC-C 12V-5A-892H(N)-1AC-C 12V-5A-892H(N)-1AC-C 12V-25A-891P-1A-C 12V-5A-892H(N)-1AC-C 1 IC13 C +12V CN8 RXD2 TXD2 RXD1 TXD1 L 1 J1 K6 CY6 J26 S14K350 CY5 R7 100/1WCX4 103/275V K4 10K 10K 10K 10K 1K S14K350 RA-362M CY2 472/250V/275V CY1 472/250V/275V SA1 1 8MH/20A 472/250V/275V M J2 400N/PSB400 1K 1K 1K 1K 8MH/20A H J4 R49 R48 R47 R46 RV3 CX3 225/275V R31 R32 R33 R34 R57 RV2 1 AC-N L2 R2 CX2 1M 225/275V CY4 472/250V/275V R1 CX1 1M 225/275V CY3 472/250V/275V RV1 S14K350 ST 1 L1 T25A 250VAC PE COM PTC1 1 CN3 CN11 1 1 FUSE1 AC-L CN1 CN20 XG-B 4 5V 3 5V 2 CG-B 1 CN10 AC-L OUT C7 104/50V CN2 CN9 AC-N OUT 1 CN6 AC-N OUT 1 CN7 AC-L OUT CN12 outdoor unit control board Circuit Diagrams 1 2 3 4 5 LED2 R17 220K/2W POWER 1 R6 1.8K CN46 CY10 222/250V D10 IN4007 CY9 222/250V R4 2K/2W TLP851/PC851 Domestic air conditioner Appendix 2U14CS1ERA-SM 11 Description of coding rules of unit model A 0 S 7 2 S G E R A Apply to˖T1;220~240V50HZ1ph DCInverter Heat pump&R410 refrigerant version number Super-match range Platform of indoor units: G(EK Platform) Nominal cooling capacity (7000BTU/h) Type of indoor unit: S(wall-mounted) Indoor unit AS09GS2ERA means9000BTU. AS12GS2ERA means12000BTU. 2 U 1 4 S C 1 E R A Apply to˖T1;220~240V50HZ1ph DCInverter Heat pump&R410 refrigerant version number Super-match range Platform of outdoor units: C(35PCM Platform) Nominal cooling capacity (14000BTU/h) Type of outdoor unit˖U(normal type) The maximum combination number Examples: AS09GS1ERA,It represents wall-mounted split type heat pump air conditioner cooling capacity is 9000BTU/h,and the power supply is 220-240V/50Hz,”S” means Easy stock ,and"E" means the refrigerant is R410A. 112 Domestic Air Conditioner 2U14CS1ERA-SM The end Sincere Forever Haier Group Chen Huimin Li Peng Yang Bifei 88936935 W Hongjin ">
Advertisement
Key Features
- DC Inverter technology for energy efficiency and precise temperature control
- Wall-mounted design for easy installation and space-saving
- Compact and sleek design blends seamlessly with any décor
- Remote control for convenient operation
- Automatic operation mode for hassle-free temperature regulation
- Air filter for improved air quality
Frequently Answers and Questions
What is the capacity of the Haier 2U14CS1ERA air conditioner?
The capacity of the Haier 2U14CS1ERA air conditioner is not specified in the provided manual.
What is the power consumption of the Haier 2U14CS1ERA air conditioner?
The power consumption of the Haier 2U14CS1ERA air conditioner is not specified in the provided manual.
What are the dimensions of the Haier 2U14CS1ERA air conditioner?
The dimensions of the Haier 2U14CS1ERA air conditioner are not specified in the provided manual.
What type of refrigerant does the Haier 2U14CS1ERA air conditioner use?
The type of refrigerant used in the Haier 2U14CS1ERA air conditioner is not specified in the provided manual.
What is the noise level of the Haier 2U14CS1ERA air conditioner?
The noise level of the Haier 2U14CS1ERA air conditioner is not specified in the provided manual.