- Industrial & lab equipment
- Electrical equipment & supplies
- Power conditioning
- Uninterruptible power supplies (UPSs)
- User manual
advertisement
▼
Scroll to page 2
CHLORIDE® FP60Z AC UPS System From 5 to 250kVA, 1-ph or 3-ph output CHLORIDE® FP RANGE Configured to order with industrial options Chloride® FP60Z Uninterruptible Power Supply (UPS) is a true industrial UPS system offering a full-IGBT innovative design and embedding all the latest technologies in power protection. Pre-defined blocks for shorter lead time BENEFITS Industrial-grade maintainability: yyInnovative design without heavy power modules and allowing an easy front access to all components yyRemovable ID Cards which safeguard the UPS parameters and facilitate control board replacement Smart access to UPS data: yyLarge colour LCD touch-pad for user interface yyEmbedded event logger (up to 2000 events) and capability to export recorded events via memory stick Industrial flexibility: yyFit-for-purpose battery selection yyGalvanic isolation: either output or input and output transformers yyWide range of electrical and mechanical options KEY FEATURES yyBi-directional rectifier to perform battery deep discharging tests into the mains yyIngress Protection IP42 as standard for harsh environmental conditions yyRobust design to continuously operate at full load at 40 °C Range Overview Applications Chloride® FP60Z is available in standard range from 5 to 160 kVA in single-phase or three-phase output configurations and can be adapted to reach up to 250 kVA output power. It offers a wide choice of DC battery voltages (110 V, 220 V or 400 V) and of output voltages (from 1x110 V to 3x415 V). yyPetrochemical and Chemical yyWater and Wastewater yyContinuous manufacturing processes The UPS uses patented digital Vector Control technology which increases the UPS performances, enables active conditioning of the load and allows adaptability to different application needs. Chloride® FP60Z features a wide input voltage tolerance, which makes the system compatible with the harshest industrial power grids. To further improve load availability and process reliability, Chloride® FP60Z is able to operate in dual distributed parallel configuration, with one or two reserve supplies, with single or dual batteries, and can include an AC bus-tie. Example of Chloride® FP60Z - 800 mm width Best-in-class performance to optimize expenses: yyReduced CAPEX - Upstream transformer, switchgear and cables are downsized thanks to high input power factor, low THDi rejection and low inrush current yyControlled OPEX - Lower power consumption thanks to high efficiency yyProven digital Vector Control technology to control the output waveform in real time, even on non linear loads CHLORIDE® FP60Z AC UPS System From 5 to 250kVA, 1-ph or 3-ph output Technical Data OUTPUT POWER AT COS PHI 0.8 (kVA) VS BATTERY VOLTAGE (Vdc) 1-ph and 3-ph input 110 Vdc 220 Vdc 400 Vdc 5 - 10 10 - 20 20 - INPUT Input Voltage Inrush Current Power Factor Frequency Range Embedded input features INTERMEDIATE DC CIRCUIT Nominal DC voltage Voltage stability in steady state Voltage ripple Current limitation Charging characteristic OUTPUT AC voltage Frequency stability Voltage stability (0-100% load variation) Overload inverter (in % of nominal power) Short-circuit clearance (in % of nominal current) Voltage distorsion Allowable power factor Allowable crest factor Embedded output features RESERVE LINE Embedded reserve line features BATTERY Type Recommended number of cells: yy Lead Acid yy Nickel Cadmium Battery current limitation Embedded battery features 3-ph input only 30 - 40 40 60 60 80 100 120 160 250 3-ph+N x 400 Vac (380, 415) ± 10 % (other voltages and tolerances on request) ≤ 1 In (without input transformer) ≤ 8 In (with input transformer) Up to 0.98 50 Hz (60 Hz factory setting) ± 5 % yy AC input isolator switch yy Surge protection with MOV lightning arrestors 110 / 220 / 400 Vdc ≤ 1 % in float mode (input within tolerance) ≤ 1 % RMS (with and without battery connected) I nominal IU according to DIN 41773 1-ph: 230 Vac (208, 220, 240) ; 110 Vac (115, 120, 127) 3-ph: 400 Vac (380, 415) ; 208 Vac (190, 200, 220) With internal oscillator ± 0.1 % With reserve synchronism ± 1 % (1 to 4 % adjustable) Static ± 1 % Dynamic VFI SS 111 as per IEC62040-3, class 1 150 %/1 min - 125 %/10 min at nominal output voltage GENERAL DATA Efficiency Operating temperature Storage temperature Relative humidity Operating altitude Cooling Ingress Protection Noise (at 1 m in front of the unit) Input/output isolation Frame colour Feet Gland plate Dimensions Embedded system features OPTIONS Rectifier yy Input isolation transformer yy Special 1-ph or 3-ph input voltage (up to 3 x 690 Vac) yy Input voltage tolerance from -20% to +15% yy Input circuit breaker with aux. contact and breaking capacity up to 70kA yy Automatic reverse phase sequence correction yy Automatic input phase failure adaptation yy Battery protection box (circuit breaker) yy Battery black start, automatic or manual mode yy DC earth fault detection yy Circuit breaker with aux. contact yy Emergency Power Off yy Circuit breaker with aux contact yy Reserve isolation transformer (H class) yy Reserve voltage stabilizer (servo-controlled) yy Stabilizer output isolator yy Parallel configuration (distributed parallel) yy Operating temperature up to 50 °C with derating yy Operationg altitude up to 3000 m with derating yy Redundant monitored fans yy G3 conformal coating on electronic cards against dust and humidity yy Space heater with thermostat or hygrostat yy Halogen free cabling yy Top cable entry yy Special frame color (RAL paint standards) yy Special feet height 200 mm or base frame yy Antivibration pads yy Additional volt-free contacts (up to 20 relays) yy Modbus RTU (RS232 or RS485) yy Modbus to TCP-IP / Profibus / SNMP yy PPVIS monitoring software Battery 1-ph and 3-ph: 250 %/100 ms - 150 %/5 s Output With 100 % linear load < 2 % With 100 % non linear load < 5 % as per IEC62040-3 0.5 lagging to 0.5 leading 3/1 yy Output switch yy Output isolation transformer class H Reserve System yy Integrated manual bypass switch yy Inbuilt input reserve line switch Type Lead Acid or Nickel Cadmium, vented or recombination 110 Vdc 220 Vdc 400 Vdc 54 to 72 108 to 144 192 to 228 88 to 98 176 to 200 320 to 323 0.1 C (Lead Acid) / 0.2 C (Nickel Cadmium) yy Inbuilt battery circuit breaker with aux. contact yy Battery reverse polarity protection and indication yy Battery Low Voltage Disconnection (LVD) yy Battery test, automatic or manual mode yy Battery room temperature sensor for battery charge compensation Up to 92 % (according to rating and config.) From 0 °C to 40 °C (without system derating) From - 20 °C to + 70 °C (battery excluded) < 95 % non condensing at 20 °C 1000 m (without system derating) Fan-assisted Internal IP20 - external IP 42 62 to 72 dB (according to rating) 2500 Vac / 1 minute RAL 7035 100 mm height with feet cover Aluminum non-magnetic, 3 mm thickness From 1 x 800 mm to 2 x 1200 mm width yy Internal cabinet lighting yy Auxiliary power socket yy Lifting Eyes yy Display language: English, French, Spanish, Russian, Turkish (factory setting) Mechanical Communication Compliance STANDARDS IEC/EN 62040-1: 2008 IEC/EN 62040-2: 2006 IEC/EN 62040-3: 2011 IEC/EN 60950-1: 2013 AMD2: 2014 Other Uninterruptible power systems (UPS) Part 1: General and safety requirements for UPS Part 2: Electromagnetic compatibility (EMC) requirements Part 3: Method of specifying the performance and test requirements Information technology equipment - Safety Part 1: General requirements IEC 60529: 2013 / IEC 61439 / IEC 60076: 2015 / IEC 60332-1-2: 2015 CONFORMITY Low Voltage Directive (LVD) EMC Directive 2006/95/EC (before April 2016) 2014/35/EU (after April 2016) 2004/108/EC (before April 2016) 2014/30/EU (after April 2016) CE Mark VertivCo.com | Global & Europe, Vertiv Industrial Systems SAS, 30, Avenue Montgolfier - BP 90 - 69684 Chassieu - France T: +33 (0)4 78 40 13 56 [email protected] To find contact in your region, please visit www.VertivCo.com © 2017 Vertiv Co. All rights reserved. Vertiv, the Vertiv logo and Chloride are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. Chloride-FP60Z-DS-EN-gl-rev0-0717
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project