CHLORIDE® FP60Z
AC UPS System
From 5 to 250kVA, 1-ph or 3-ph output
CHLORIDE® FP RANGE
Configured to order with industrial options
Chloride® FP60Z Uninterruptible Power Supply (UPS) is a true
industrial UPS system offering a full-IGBT innovative design
and embedding all the latest technologies in power protection.
Pre-defined blocks for shorter lead time
BENEFITS
Industrial-grade maintainability:
yyInnovative design without heavy power
modules and allowing an easy front access to
all components
yyRemovable ID Cards which safeguard the
UPS parameters and facilitate control board
replacement
Smart access to UPS data:
yyLarge colour LCD touch-pad for user
interface
yyEmbedded event logger (up to 2000 events)
and capability to export recorded events via
memory stick
Industrial flexibility:
yyFit-for-purpose battery selection
yyGalvanic isolation: either output or input and
output transformers
yyWide range of electrical and mechanical
options
KEY FEATURES
yyBi-directional rectifier to perform battery
deep discharging tests into the mains
yyIngress Protection IP42 as standard for
harsh environmental conditions
yyRobust design to continuously operate at full
load at 40 °C
Range Overview
Applications
Chloride® FP60Z is available in standard
range from 5 to 160 kVA in single-phase or
three-phase output configurations and can
be adapted to reach up to 250 kVA output
power. It offers a wide choice of DC battery
voltages (110 V, 220 V or 400 V) and of
output voltages (from 1x110 V to 3x415 V).
yyPetrochemical and Chemical
yyWater and Wastewater
yyContinuous manufacturing processes
The UPS uses patented digital Vector
Control technology which increases the UPS
performances, enables active conditioning of
the load and allows adaptability to different
application needs.
Chloride® FP60Z features a wide input
voltage tolerance, which makes the system
compatible with the harshest industrial
power grids.
To further improve load availability and
process reliability, Chloride® FP60Z is able to
operate in dual distributed parallel
configuration, with one or two reserve
supplies, with single or dual batteries, and
can include an AC bus-tie.
Example of Chloride® FP60Z - 800 mm width
Best-in-class performance to optimize
expenses:
yyReduced CAPEX - Upstream transformer,
switchgear and cables are downsized thanks
to high input power factor, low THDi rejection
and low inrush current
yyControlled OPEX - Lower power consumption
thanks to high efficiency
yyProven digital Vector Control technology to
control the output waveform in real time, even
on non linear loads
CHLORIDE® FP60Z
AC UPS System
From 5 to 250kVA, 1-ph or 3-ph output
Technical Data
OUTPUT POWER AT COS PHI 0.8 (kVA) VS BATTERY VOLTAGE (Vdc)
1-ph and 3-ph input
110 Vdc
220 Vdc
400 Vdc
5
-
10
10
-
20
20
-
INPUT
Input Voltage
Inrush Current
Power Factor
Frequency Range
Embedded input features
INTERMEDIATE DC CIRCUIT
Nominal DC voltage
Voltage stability in steady state
Voltage ripple
Current limitation
Charging characteristic
OUTPUT
AC voltage
Frequency stability
Voltage stability
(0-100% load variation)
Overload inverter
(in % of nominal power)
Short-circuit clearance
(in % of nominal current)
Voltage distorsion
Allowable power factor
Allowable crest factor
Embedded output features
RESERVE LINE
Embedded reserve line features
BATTERY
Type
Recommended number of cells:
yy
Lead Acid
yy
Nickel Cadmium
Battery current limitation
Embedded battery features
3-ph input only
30
-
40
40
60
60
80
100
120
160
250
3-ph+N x 400 Vac (380, 415) ± 10 %
(other voltages and tolerances on request)
≤ 1 In (without input transformer)
≤ 8 In (with input transformer)
Up to 0.98
50 Hz (60 Hz factory setting) ± 5 %
yy
AC input isolator switch
yy
Surge protection with MOV lightning arrestors
110 / 220 / 400 Vdc
≤ 1 % in float mode (input within tolerance)
≤ 1 % RMS (with and without battery connected)
I nominal
IU according to DIN 41773
1-ph: 230 Vac (208, 220, 240) ; 110 Vac (115, 120, 127)
3-ph: 400 Vac (380, 415) ; 208 Vac (190, 200, 220)
With internal oscillator ± 0.1 %
With reserve synchronism ± 1 % (1 to 4 % adjustable)
Static ± 1 %
Dynamic VFI SS 111 as per IEC62040-3, class 1
150 %/1 min - 125 %/10 min at nominal output voltage
GENERAL DATA
Efficiency
Operating temperature
Storage temperature
Relative humidity
Operating altitude
Cooling
Ingress Protection
Noise (at 1 m in front of the unit)
Input/output isolation
Frame colour
Feet
Gland plate
Dimensions
Embedded system features
OPTIONS
Rectifier
yy
Input isolation transformer
yy
Special 1-ph or 3-ph input voltage
(up to 3 x 690 Vac)
yy
Input voltage tolerance from -20% to +15%
yy
Input circuit breaker with aux. contact
and breaking capacity up to 70kA
yy
Automatic reverse phase sequence correction
yy
Automatic input phase failure adaptation
yy
Battery protection box (circuit breaker)
yy
Battery black start, automatic or manual mode
yy
DC earth fault detection
yy
Circuit breaker with aux. contact
yy
Emergency Power Off
yy
Circuit breaker with aux contact
yy
Reserve isolation transformer (H class)
yy
Reserve voltage stabilizer (servo-controlled)
yy
Stabilizer output isolator
yy
Parallel configuration (distributed parallel)
yy
Operating temperature up to 50 °C with derating
yy
Operationg altitude up to 3000 m with derating
yy
Redundant monitored fans
yy
G3 conformal coating on electronic cards
against dust and humidity
yy
Space heater with thermostat or hygrostat
yy
Halogen free cabling
yy
Top cable entry
yy
Special frame color (RAL paint standards)
yy
Special feet height 200 mm or base frame
yy
Antivibration pads
yy
Additional volt-free contacts (up to 20 relays)
yy
Modbus RTU (RS232 or RS485)
yy
Modbus to TCP-IP / Profibus / SNMP
yy
PPVIS monitoring software
Battery
1-ph and 3-ph: 250 %/100 ms - 150 %/5 s
Output
With 100 % linear load < 2 %
With 100 % non linear load < 5 % as per IEC62040-3
0.5 lagging to 0.5 leading
3/1
yy
Output switch
yy
Output isolation transformer class H
Reserve
System
yy
Integrated manual bypass switch
yy
Inbuilt input reserve line switch
Type Lead Acid or Nickel Cadmium,
vented or recombination
110 Vdc
220 Vdc
400 Vdc
54 to 72
108 to 144
192 to 228
88 to 98
176 to 200
320 to 323
0.1 C (Lead Acid) / 0.2 C (Nickel Cadmium)
yy
Inbuilt battery circuit breaker with aux. contact
yy
Battery reverse polarity protection and
indication
yy
Battery Low Voltage Disconnection (LVD)
yy
Battery test, automatic or manual mode
yy
Battery room temperature sensor for battery
charge compensation
Up to 92 % (according to rating and config.)
From 0 °C to 40 °C (without system derating)
From - 20 °C to + 70 °C (battery excluded)
< 95 % non condensing at 20 °C
1000 m (without system derating)
Fan-assisted
Internal IP20 - external IP 42
62 to 72 dB (according to rating)
2500 Vac / 1 minute
RAL 7035
100 mm height with feet cover
Aluminum non-magnetic, 3 mm thickness
From 1 x 800 mm to 2 x 1200 mm width
yy
Internal cabinet lighting
yy
Auxiliary power socket
yy
Lifting Eyes
yy
Display language: English, French, Spanish,
Russian, Turkish (factory setting)
Mechanical
Communication
Compliance
STANDARDS
IEC/EN 62040-1: 2008
IEC/EN 62040-2: 2006
IEC/EN 62040-3: 2011
IEC/EN 60950-1: 2013
AMD2: 2014
Other
Uninterruptible power systems (UPS) Part 1: General and safety requirements for UPS
Part 2: Electromagnetic compatibility (EMC)
requirements
Part 3: Method of specifying the performance and
test requirements
Information technology equipment - Safety Part 1: General requirements
IEC 60529: 2013 / IEC 61439 / IEC 60076: 2015 /
IEC 60332-1-2: 2015
CONFORMITY
Low Voltage Directive (LVD)
EMC Directive
2006/95/EC (before April 2016)
2014/35/EU (after April 2016)
2004/108/EC (before April 2016)
2014/30/EU (after April 2016)
CE Mark
VertivCo.com |
Global & Europe, Vertiv Industrial Systems SAS,
30, Avenue Montgolfier - BP 90 - 69684 Chassieu - France
T: +33 (0)4 78 40 13 56
[email protected]
To find contact in your region, please visit www.VertivCo.com
© 2017 Vertiv Co. All rights reserved. Vertiv, the Vertiv logo and Chloride are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every
precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.
Chloride-FP60Z-DS-EN-gl-rev0-0717

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement