MAX 1500 / MAX 2200 - Automated Gates and Equipment

MAX 1500 / MAX 2200 - Automated Gates and Equipment
www.max.us.com
SAFETY SENSORS REQUIRED FOR UL 325 2016
CONFORMS TO UL STD 325
UL CLASS - I, II, III, IV
CERTIFIED TO CAN/CSA STD
C22.2 NO. 247
Residential/Commercial
Brushless DC Slide Gate Operators
Made in USA
4009963
MAX 1500 / MAX 2200
Installation and Owners Manual
Version 7
Table of contents
MAX 1500 / MAX 2200 Specifications
Important Safety Information
UL 325 Model Classifications
UL 325 Required Entrapment Protection
UL 325 Compliant Installation Requirements
Intended Use of Slide Gate Operator
2
2
3
3
4
5
Installation
Operator in Front Mounting Position (Standard)
Connect Chain to Gate - Front Mounting Position
Operator in Rear Mounting Position (Alternate)
Connect Chain to Gate - Rear Mounting Position
Dual Gate Operators - Front Mounting Position
Optional Remote Power Supply Kit - MAX Magic Box
Solar - Optional
Install Warning Signs
Photocell Entrapment Protection
Sensing Edge Entrapment Protection
In-Ground Loops
6
7
8
9
10
11
12
13
14
15
16
Wiring operator
Gate Operator System Overview
Entrapment Protection Wiring
High Voltage Input AC Power
Low Voltage Remote Power Supply Kit - Optional
Solar Power Connection - Optional
Secondary Operator to Matrix 1
Turn ON / OFF Operator Power
17-18
18-20
21
22
23
24
25
matrix 1
Matrix 1 Overview
Wiring Overview
Primary Gate - Open Left / Open Right
Close Timer
Selectable Gate Speed Control
Battery Back-Up Mode
Anti-Tailgate
Single Pass Anti-Tailgate
Radio Receiver
Radio Safety Pause
Gate in Motion Alarms
OBD Port Black Box
Maglock
Loop Detectors
In-Ground Loop Connection
ID Plug
Gate Tamper
UL Entrapment LEDs
Emergency Vehicle / Max Open Inputs
Gate Disable
Partial Open
UL Alarm Warning Light Input
Gate Status Monitoring
OPEN / STOP / CLOSE Connection
CLOSING Photocell Connection
Motor Motion LEDs
Gate Operators Communication LEDs
24V Power for Matrix 1
Battery in Use LED
Gate Shut-Off Switch
External Open/Close Key Switch - Optional
Adjustments
Open and Close Limits
Reverse Sensor (ERD)
38
39
Maintenance
Primary/Single and Secondary Operator Wiring Schematics 40-41
42
Qualified gate operator technician
42
End user/Home owner
43
Electronic Gate OPEN / CLOSE
43
Mechanical Gate Release (Manual Release)
44
Audible Alarm
45
Replacement Parts List
46
Warranty
options/unique features
Gate Tamper Feature
Magnetic Dynamic Brake System
Gear Reducer
Partial Open Feature
Gate Disable Feature
Event History Download
MAX Chain Release Mechanism - Optional
47
48
48
49
50
50
51
© 2015 Maximum Controls LLC.
All rights reserved. No part of this manual may be reproduced in any
means: graphics, electronics or mechanical, including photocopying
without the expressed written permission of the publisher. Materials
components and specifications are subject to change without notice.
26
27
28
28
28
28
29
29
30
30
30
30
31
31
31
32
32
32
32
33
33
33
34
34
34
34
35
35
35
36
37
1
MAX 1500 / 2200 specifications
UL 325 Class of Operation - Class I, II, III, IV
Gate Type - Vehicular Slide Gate
Max Gate Length - 50 ft
Max Gate Weight:
• MAX 1500 - 1500 lbs Level Gate; 1000 lbs Uphill Gate - 5° Max
• MAX 2200 - 2200 lbs Level Gate; 1500 lbs Uphill Gate - 5° Max
Opening Time - Selectable speed control (MAX - 12 inch per second)
Cycles per Hour AC Power - Continuous
Battery Back-Up Cycles (Batteries fully charged):
• MAX 1500 - approximately 100 cycles
• MAX 2200 - approximately 100 cycles
NOTE: The number of gate cycles using ONLY battery back-up power will vary depending on the weight
of the gate, the gate length, the operating condition of the gate, temperature and the amount of charge
the batteries have at the beginning of the battery power only operation.
Input AC Power - Switchable: 115VAC or 230VAC single phase
Motor:
• MAX 1500 - 1/2 HP 24VDC Brushless (6 million cycles)
• MAX 2200 - 1 HP 24VDC Brushless (6 million cycles)
Chain Size - #40
Operating Temperature: -4°F to 158°F (-20°C to 70°C)
Entrapment Protection:
- UL 325 Type A Inherent (ERD sensor)
- Inputs for NORMALLY CLOSED (N.C.)
UL 325 Type B1 (photo cell)
and Type B2 (sensing edge)
29”
7 1/2”
19”
14 1/2”
important safety information
WARNING – To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the
non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the
gate operator properly can increase the risk of injury or death.
5. Use the emergency release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate
hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. SAVE THESE INSTRUCTIONS
2
ul 325 model classifications
AUTHORIZED
PERSONNEL
ONLY
CLASS I
CLASS III
Residential Vehicular Gate Operator - A vehicular gate operator
(opener or system) intended for use in a home of one to four
single family dwellings, or a garage or parking area associated
therewith.
Industrial/Limited Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for uses
in an industrial location, loading dock area or other location
not intended to service the general public.
SECURITY
CLASS II
CLASS IV
Commercial/General Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for use in
a commercial location or building such as a multi-family
housing unit (five or more single family units) hotel, garages,
retail store or other building servicing the general public.
Restricted Access Vehicular Gate Operator - A vehicular gate
operator (opener or system) intended for use in a guarded
industrial location or buildings such as airport security area or
other restricted access locations not servicing the general
public, in which unauthorized access is prevented via
supervision by security personnel.
ul 325 required entrapment protection
This vehicular gate operator must be installed with at least two independent entrapment protection means as specified in the table and
definitions below.
The same type of device shall not be used for both entrapment protection means. Use of a single device to cover both the opening and
closing directions is in accordance with the requirement, however, a single device is not required to cover both directions. This operator
has been provided with type A entrapment protection. The installer is required to install additional entrapment protection devices in each
entrapment area.
Gate Type
Class I & II
Class III & IV
Swing Gate
A, B1*, B2*, C, D
A, B1*, B2*, C, D, E
Slide Gate
A, B1*, B2*, D
A, B1*, B2*, D, E
A - Inherent entrapment protection system.
C - Inherent adjustable clutch or pressure relief device.
B1 - Provision for connection of a non-contact sensor
(photoelectric sensor or the equivalent).
D - Provision for connection of an actuating device
requiring continuous pressure to maintain opening
or closing motion of the gate.
B2 - Provision for connection of a contact sensor
(edge device or the equivalent).
E - An audio alarm.
* B1 and B2 means of entrapment protection must be MONITORED.
3
ul 325 compliant
installation requirements
A Install the gate operator only when:
1 The operator is appropriate for the construction of the gate and the usage Class of the gate,
2 All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.83 m) above the
ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that
portion of the adjacent fence that the gate covers in the open position,
3 All exposed pinch points are eliminated or guarded, and
4 Guarding is supplied for exposed rollers.
B The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The
pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with
the vehicular gate during the entire path of travel of the vehicular gate.
C The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and
closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
D The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the
operator clutch or pressure relief valve to compensate for a damaged gate.
E For gate operators utilizing Type D protection:
1 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving,
2 A gate operator shall additionally be provided with a placard that is marked in letters at least 1/4-in (6.4-mm) high with the word
“WARNING” and the following statement or the equivalent: “Moving Gate Has Potential of Inflicting Injury or Death - Do Not Start
Gate Unless Path is Clear”.
3 An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and
4 No other activation device shall be connected.
F Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is
prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a
security feature to prevent unauthorized use.
G The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.
H A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
I For gate operators utilizing a non-contact sensor:
1 See instructions on the placement of non-contact sensors for each Type of application,
2 Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and
3 One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable
by a moving gate or barrier.
J For a gate operator utilizing a contact sensor:
1 One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing
edge, and post mounted both inside and outside of a vehicular horizontal slide gate.
2 One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
4 A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate
operator is not subjected to mechanical damage.
5 A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions
shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or
similar obstruction. A wireless device shall function under the intended end-use conditions.
6 One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge
of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall
be located on the bottom edge.
7 One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
4
intended use of
slide gate operator
The operator is intended for use on a VEHICULAR slide gate ONLY. It is intended to be used WITH appropriate entrapment
protection safety devices and in-ground vehicle loop detection system. This operator has a inherent entrapment protection
system and requires additional external monitored entrapment protection devices (Non-contact Photocells or contact sensing
edges) for each entrapment area prior to gate operation.
Opening Direction 10K Sensing Edge: Helps guard against the opening gate from entrapment. (Wireless)
Gate Pickets: The space between the gate pickets should be LESS than 2 1/4” or wire mesh should be installed.
Wire Mesh: 2” x 2” at least 6 ft high. Installed on gate when the space between the gate pickets is MORE
than 2 1/4”. See “A2” on previous page for more information.
Warning Signs: Should be installed on both sides of gate area and easily visible.
Guide Rollers: Must be installed for safety.
Closing Direction 10K Sensing Edge: Helps protect the gate operator
from accidentally closing on vehicles in the gate’s closing path. (Wireless)
Opening Direction 10K Sensing Edge: Helps guard against the
opening gate from entrapment between wall and gate.
Closing Direction Photocell: Helps
protect the gate operator from
accidentally closing on vehicles in the
gate’s closing path.
M
Seovin
KE rio g
withEP CL us Ga
te
Do out prEAR! In
C
in not ior wa Gajury an
th let
te
Th e ga child rning may o Ca
r
Peis en te ar ren .
mov D us
de tra ea. op
e at ea e
str nc
er
th
ian e is
ate
an
s m fo
y tim
the
us r ve
ga
e
t us hic
te
e se les
or
pla
pa only.
y
rate
en
tra
nc
e.
En
tra
pm
en
tA
rea
Physical Stops:
Install on both ends of gate
rail to limit the travel of
gate to the fully open and
fully closed positions.
En
tra
Opening Direction Photocell: Helps
guard against the opening gate from
entrapment.
In-Ground Loops: Help
protect the gate operator
from accidentally opening
and/or closing on vehicles
in the gate’s path
pm
en
tA
rea
Physical Stop
Pedestrians MUST use a separate entrance.
The gate operator IS NOT intended to be used on a
PEDESTRIAN gate.
NOTE: sensors MUST be MONITORED
and NORMALLY CLOSED (N.C.)
5
installation
Read and understand this entire manual before installation. Check with the local building department prior to installing this gate
operator to comply with local building code requirements. The gate must be installed in a location so that enough clearance is
supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment.
operator in front mounting position (standard)
The gate must be properly installed and work freely in both directions prior to installation of the gate operator.
Operator Position on Concrete Pad
V-Rail
Physical Stop
2” Gate Frame
1.5”
6.2”
5” 4”
12.75”
Conduit Guidelines and Suggestions
Conduit
Area
7.5”
7.5”
10.5”
8.625”
24”
4”
• REQUIRED - AC input power wire.
• Entrapment protection photocell . See page 14.
• Entrapment protection sensing edge. See page 15.
• In-ground loop wires. See page 16.
6.75”
10.5”
Cover
6.5”
6.75”
Concrete Pad
24”
ONE Entrapment protection sensor MUST installed or
operator will NOT function. It MUST be MONITORED
and NORMALLY CLOSED (N.C.)
Outside Property
Illustrations not to scale
Gate in Closed Position
Inside Property
Operator in Front Position
Guide rollers MUST be Installed to keep gate upright.
Operator MUST be level.
1/2
See page 7 for chain information.
Secure gate operator to
concrete pad with four
(4) 1/2” x 3” (min)
sleeve anchors.
Install physical stops on BOTH
ends of rail to keep gate from
traveling off of rail.
6” above ground to avoid any flooding of the operator.
Positive Stop
Check local building
codes in your area for
depth of concrete
before installation.
“Optional” Input Power Note:
24VDC low voltage power wires can be run
from a remote power supply (MAX Magic
Box) to power the gate operator if desired.
See page 11 for more information.
6
Conduit Run
Concrete Pad
Input Power
Concrete Depth Note: The heavier the gate, the deeper the concrete
pad should be. At least two feet recommended for heavier gate.
installation
connect chain to gate - front mounting position
Top View of Operator
NOTE: 25 ft of #40 nickel plated chain included.
Minimum distance between the drive gear and gate is 4”.
4” Min
4” Min
Drive
Gear
NO
YES
Operator is too far from gate.
Chain is NOT parallel to gate.
IMPORTANT: Operator and chain MUST be parallel to gate or the idler wheels could fail.
Use the “Fine Tune” adjustment on the gate bracket connection bolt and make sure the
chain runs through the idler wheels without binding on the side chain guides.
4” Min
YES
NO
Ga
te B
rac
ket
Operator is too close to gate.
Chain is NOT parallel to gate.
4” Min
Fine Tune
Adjustment
Side Chain Guide
Side Chain Guide
Idler Wheel
NO
NO
Operator is NOT parallel to gate.
Chain is NOT parallel to gate.
Back View of Operator
YES
Chain brackets MUST
remain same height as
idler wheels.
NOTE: The chain should
sag no more than one (1)
inch per 10 feet of travel.
Do not over tighten the
chain.
Idler Wheels
7.5”
13.5”
Factory installed
position
Concrete Pad
NO
7.5”
13.5”
Chain
Bracket
DO NOT mount chain bracket
too high or too low on gate.
6”
7
installation
operator in rear mounting position (alternate)
The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
The chain is not visible when looking from outside of the property.
Operator Position on Concrete Pad
V-Rail
2” Gate Frame
Physical Stop
1.5”
4”
6.2”
5” 4”
Conduit Guidelines and Suggestions
12.75”
• REQUIRED - AC input power wire.
• Entrapment protection photocell. See page 14.
Conduit
Area
7.5”
• Entrapment protection sensing edge. See page 15.
7.5”
10.5”
8.625”
• In-ground loop wires. See page 16.
24”
ONE Entrapment protection sensor MUST installed or
operator will NOT function. It MUST be MONITORED
and NORMALLY CLOSED (N.C.)
6.75”
10.5”
Cover
6.5”
6.75”
Concrete Pad
24”
Outside Property
Illustrations not to scale
Gate in Closed Position
Inside Property
Operator in Rear Position
Guide rollers MUST be Installed to keep gate upright.
Operator MUST be level.
Secure gate operator to
concrete pad with four
(4) 1/2” x 3” (min)
sleeve anchors.
1/2
See page 9 for chain information.
Physical Stop
6” above ground to avoid any flooding of the operator.
Install positive stops on BOTH ends of rail
to keep gate from traveling off of rail.
“Optional” Input Power Note:
24VDC low voltage power wires can be run
from a remote power supply (MAX Magic
Box) to power the gate operator if desired.
See page 11 for more information.
8
Check local building
codes in your area for
depth of concrete
before installation.
Conduit
Run
Input Power
Concrete Pad
Concrete Depth Note: The heavier the gate, the deeper the concrete
pad should be. At least two feet recommended for heavier gate.
installation
connect chain to gate - rear mounting position
NOTE: 25 ft of #40 nickel plated chain included.
Top View
Gate
Gate
Drive
Gear
Ga
te B
rac
Pulley Wheel
Safety Cover
ket
Fine Tune
Adjustment
YES
Lower chain does NOT
align with upper chain.
Operator and chains
MUST remain
parallel to gate.
Upper and lower
chain MUST align
with each other.
NOTE: The chain should sag
no more than one (1) inch per
10 feet of travel. Do not over
tighten the chain.
Upper chain bracket
MUST remain same
height as drive gear.
Pulley Wheel
(not supplied)
Same height as
idler wheel.
Lower chain Bracket
MUST remain same
height as pulley wheel.
16.5”
22.5”
Back View
IMPORTANT: Make sure that chain is
parallel to gate. Incorrect installation
will cause excessive noise, idler and
pulley wheel wear and chain stretching.
YES
Limit sensors will need to be relocated
to align with rear chain configuration.
See page 38 for more information.
Drive
Gear
IMPORTANT:
Idler
Wheel
DO NOT mount
chain brackets
too high or too
low on gate.
NO
Chain
Bracket
Move operator wheel
to lower hole position.
4.5”
10.5”
Gray Limit sensor
MUST be in the
OPEN position.
Chain
Bracket
NO
6”
Concrete Pad
Modify Cover for Rear Mounting Position
Drill 2” dia. hole for
upper chain exit.
Cut out cover
between new hole
and existing chain
exit slot.
Approx.1.5”
16.5”
Remove
Make sure cuts are
plumb with existing
chain exit slot.
Existing chain
exit slot.
9
installation
dual gate operators - front mounting position
The gates must be properly installed and work freely in both directions prior to the installation of the dual gate operators.
See “Operator in Front Mounting Position” on page 6 for operator positions.
Outside Property
Illustrations not to scale
Gates Full Closed Position
Secondary Operator
Primary Operator
Has NO Matrix 1 Control Board
Inside
Property
See page 7 for chain information.
Input
Power
RS-485
Conduit Runs
Conduit Runs
Input
Power
Conduit Guidelines and Suggestions
• REQUIRED - AC input power wire to EACH gate operator.
• REQUIRED - RS-485 wires CONNECT operators together.
• Entrapment protection photocell wired to EACH Corresponding OPERATOR. See below & page 14.
• Entrapment protection sensing edge wired to EACH Corresponding OPERATOR. See below & page 15.
ONE REQUIRED
• Normally open photocell safety protection wires to MATRIX 1 See below & page 14.
• In-ground loop wires to MATRIX 1. See page 16.
• Optional external OPEN/CLOSE key switch wires from EACH OPERATOR to key switch. See page 37.
Each entrapment protection device MUST be connected to corresponding gate operator.
Dual Gates CLOSING direction Thru-Beam Photocell ONLY:
See separate wiring instruction sheet.
CLOSING direction Photocell
Reflector
OPENING direction Sensing Edge
OPENING
direction
Photocell
To MC-200 Edge 2
or Photo Cell Inputs
10
OPENING direction
Sensing Edge
OPENING/CLOSING
Sensing Edges
OPENING direction
Sensing Edge
To MC-200 Edge 2 or Photo Cell Input
To MC-200 Edge 2 or Photo Cell Input
To MC-200 Edge 2 or Photo Cell Input
To MC-200 Edge 2 or Photo Cell Input
To MC-200 EDGE 1 Input
OPENING direction Sensing Edge
OPENING
direction
Photocell
To MC-200 Edge 2
or Photo Cell Inputs
Secondary Operator
Primary Operator
NO Matrix 1
Matrix 1
See pages 14-15 for installation instructions.
See pages 19-20 for wiring instructions.
installation
optional remote power supply kit - max magic box
A remote power supply is for installations where it is too costly or difficult to trench a 115/230 VAC power line to the operator
but instead run a low voltage power line to the operator. A MAX Magic Box Kit (sold separately) is required to remotely install a
MAX Toroid 15 Amp Box.
Install MAX Magic Box near the 115 VAC or 230 VAC input AC power source. See tables for MAX distance away from operator.
See page 22 for MAX Magic Box wiring instructions.
NOTE: A MAX Magic Box kit is required for EACH gate operator when using dual gate operators.
MAX Magic Box
Near Power Source
115/230 VAC Power Source
Distance - See tables below
2-Wires, 24VDC Low Voltage Power
W
PO
4
-2 LY
PS UPP
AX ER S
Ca
bin
et
Re
mo
15 te
Am Tor
p B oid
ox
PO
SA
SE P
FU M
A
7
in
N R
E
WF
PO OF
wa
VOrran
if IDEty
la
RE be D
MO l is
VE
D
W
AR
NIN
G
!
H
VO IGH
LT
A
di
po scon GE
Sold Separately
ER
WF
PO OF
IN
AC
it
t
or Volt
23 ag
0V e
AC :
wa
VOrran
if IDEty
la
RE be D
MO l is
VE
D
Uphill Gate - 5° Max
Model Gate Weight Max Wire Distance - Wire Gauge
MAX 1500 1000 lbs MAX
300 ft - 8AWG
MAX 2200 1500 lbs MAX
300 ft - 8AWG
Low
Voltage
To Operator
24 VDC
no Cond
t su ui
pp t
lied
High
Voltage
See page 22 for
MAX Magic Box
wiring instructions.
Wi
Nure
ts
Input Power
Po
Cower/S
nn ol
ect ar
or In
N
O
Se
lec
11 t In
5V pu
w
ne
se er
rvic be ct
ing fore
un
Co
ver
AC
Level Gate
Model Gate Weight Max Wire Distance - Wire Gauge
MAX 1500 1500 lbs 300 ft - 10AWG 500 ft - 8AWG
MAX 2200 2200 lbs 300 ft - 10AWG 500 ft - 8AWG
230V
230V
le
c
11 t In
5V pu
AC t
or Volt
23 ag
0V e
AC :
SE P
FU M
A
7
M
ad
e
O
IN
AC
Se
we ne
se r
rvic be ct
ing fore
un
it
Re
m
15 ote
Am Tor
p B oid
ox
U
e
in
U
SA
At MAX Magic Box
ad
M
W
AR
NIN
G
!
H
VO IGH
LT
A
di
po scon GE
4
-2 LY
PS UPP
AX R S
M WE
M
MAX
Magic
Box Kit
Inp
ut
A
Po C
we
r
At Gate Operator
24
V
Vo DC L
lt
o
Po age w
we
r
Ground Level
Distance - See tables above
Conduit
Concrete Pad
24VDC Low Voltage Power
11
installation
solar - Optional
Refer to Solar application guide.
l
ne
Pa lt
lar 4 Vo
o
S 2
MAX
Solar
Power
Kit
Po
Cower/S
nn ol
ect ar
or In
Wi
Nure
ts
el
an
r Pnics
a
l
So ctro
Ele Box
MAX Solar Power Kit: MUST be used
when using solar power, sold separately.
Solar Panel: must be mounted facing
south. It must get full sunlight throughout
the day, NO shadow obstructions.
MAX Solar Kit
Solar Panel Electronics Box
Solar Power
Conduit
12
installation
install warning signs
A minimum of two (2) WARNING SIGNS shall be installed,
one on each side of the gate where easily visible.
M
Seovin
ri g
Moving Gate Can Cause
Serious Injury or Death
Moving Gate Can Cause
KEEP CLEAR! Gate may move at any time
Serious Injury or Death
without prior warning.
KE
EP ou G
witho
CL s ate
Do ut prEAR! In
C
in not ior wa Gajury an
the let
te
Th ga child rning ma o Ca
Peis en te ar ren . y mor D us
de tra ea. op
ve ea e
str nc
erate
at
ian e is
an th
s mu for
y tim
the
ga
st vehic
e
us
te
e se les
or
pla
pa only.
y
rate
en
tra
nc
e.
KEEP CLEAR! Gate may move at anyDo
time
not let children operate the gate or play
without prior warning.
in the gate area.
Do not let children operate the gate orThis
playentrance is for vehicles only.
in the gate area.
Pedestrians must use separate entrance.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
13
installation
photocell entrapment protection
Install photocells to help protect against entrapment during cycling of the gate (entrapment protection).
ONE entrapment protection sensor MUST be installed and connected to “Edge 1 CLOSING direction” on MC-200 motor
controller or operator will NOT function. Entrapment protection sensors MUST be MONITORED and NORMALLY CLOSED (N.C.).
IMPORTANT: Entrapment Protection Photocells MUST
OPENING Direction
be Monitored Normally Closed Type. See page 20.
Outside Property
Illustrations not to scale
Wall
Gate Closed
Beam: 5” or LESS from OPEN gate.
Photo Beam
Entrapment Area
Run conduit to operator
OPENING direction photocell to
MC-200 motor controller, Monitored.
Normally CLOSED (N.C.)
Inside Property
IMPORTANT: Photocells MUST
be in alignment or fault will occur.
Photocell Beam Height
Install photocells on either side of gate, as close as
practical to the gate but no further away than 5”.
5”
or
Less
5”
or
Less
Inside Property
Beam Height:
21” for most
installations but No
higher than 27.5”
above ground.
Wall
Gate
Outside Property
See pages 19-20 for wiring instructions.
Outside Property
CLOSING Direction
CLOSING direction photocell to
MC-200 motor controller, Monitored.
Normally CLOSED (N.C.)
Run conduit to operator
Beam: 5” or LESS
from CLOSED gate.
Entrapment Area
Gate Closed
IMPORTANT: Photocells MUST
be in alignment or fault will occur.
NOTE: Photo input on Matrix 1 is NOT
MONITORED (Normally OPEN) and is
NOT UL 325 entrapment protection.
14
Inside Property
Wall
installation
Sensing edge entrapment protection
Install sensing edges to help protect against entrapment during cycling of the gate (entrapment protection).
ONE entrapment protection sensor MUST be installed and connected to “Edge 1 CLOSING direction” on MC-200 motor
controller or operator will NOT function. Entrapment protection sensors MUST be MONITORED 10K NORMALLY CLOSED (N.C.)
TYPE and a GEM-104 module MUST be installed.
OPENING Direction
Outside Property
Maximum Control recommends installing a Sensing edge in this area
to protect against entrapment between the OPENING gate and wall.
OPENING direction
Sensing Edge
Wall
Illustrations not to scale
Wireless
Module
Gate Closed
Entrapment Area
OPENING direction
Sensing Edge
IMPORTANT: Sensing edges MUST be Monitored 10K Normally
Closed Type and a GEM-104 module MUST be installed. See page 20.
Inside Property
Outside Property
CLOSING Direction
Entrapment Area
CLOSING direction
Sensing Edge
Wireless
Module
OPENING direction
Sensing Edge
Gate Closed
Wall
Wireless
Module
Sensing Edges
Wireless
Module
Wall
Install along entire edge of
the gate to help protect
against entrapment or gate
hitting a vehicle.
Inside Property
See pages 19-20 for wiring instructions.
WIRELESS NOTE: Refer to the
instruction sheet that comes with the
wireless module for wiring and
mounting instructions when using
wireless option.
Self-Supporting Post
OPENING direction
Sensing Edge
Gate Closed
CLOSING direction Sensing Edge
Wireless
Module
CLOSING direction
Sensing Edge
OPENING
OPENING direction
direction Sensing
Sensing
Edge
Edge
MG
L-T
Mo X2
nit 0
Ga ore
te d
Lin
k
Mil
lerE
dge
OPENING
direction
Sensing
Edge
(Wireless)
If a self-supporting post is being used, then sensing edges need to
be installed on EACH side of the post to protect against entrapment
in the OPENING and CLOSING direction of gate travel.
15
installation
in-ground loops
Install in-ground loops to help protect vehicles from a moving gate. See pages 27 & 31 for wiring instructions.
Refer to loop maunufacturer’s
instructions to determine
specific loop dimensions.
Outside Property
It is recommended that
a licenced installer
perform this work.
Safety
Loop
4 ft
4 ft
Illustration not to scale
Side View of
Saw Cut
4 ft
Sealant
Safety
Loop
Saw Cut
Backer Rod
4 ft
1 1/2”
Typical
Run in-ground
loops conduit to
Matrix 1.
Loop Wire
4 ft min.
1/4” Saw Cut
Exit
Loop
Pavement
4 ft
Safety Loops
4 ft
Loop lead wires are twisted 6
twists per foot minimum inside
conduit.
Are placed on each side of the gate
to prevent the gate from closing on
a vehicle in it’s path. They will stop
or reverse the cycling of the gate
while a vehicle is in or near the
gate’s pathway.
Inside Property
EXIT
Exit Loop
Matrix 1 Wiring
Automatically opens the gate for
exiting vehicles without having to
use a radio transmitter (remote
control). The exit loop can be placed
a minimum of 4 feet away from the
safety loop or far enough away from
the gate so it has opened by the time
the vehicle approaches it.
CENTER
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
1 TIME
PRIMARY
GATE
OPEN
LEFT
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
SAFETY
ANTI
TTAILGATE
EXIT
Safety loops need
to be wired in series.
ON
EXIT
CENTER
SAFETY
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
Lead Wires
PARTIAL
AL
EN
OPEN
ID PLUG
ERROR
MOTOR MOTION
TION
ID
PLUG
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
12VDC
GND
OPEN
COM
CLOSE
GATE
GA
STATUS
STAT
24VDC
BATTERY
IN USE
POWER
24V
GND
COM
GATE DISABLE
FIRE DEPT
RADIO GND
GND
RADIO SIG.
Outside Property
SAFETY LOOP
SAFETY LOOP
EXIT LOOP
Inside Property
16
MATRIX 1
Loop Detector Inputs
See page 31.
Wiring operator
Check with local building department prior to installing any permanent wiring on this gate operator. Make sure all wiring
complies with local code requirements.
Gate Operator System Overview
Gate Operator
1 Matrix 1: Manages control panel operations. Manages
MA
TRIX
2
1
/CL
OS
EXIT
OFF
EC
TR
CENT
ER
SAFET
Plu
OFF
1
ON
ER
OL
MAG
DELALOCK
Y
1.5
Sec
S
2Sec
D
MAG
LOCK
COM
NC
MIN
GA
TAM TE
PER
OFF MA
X
E TI
MER
Tam
per
NO
COM
Tam GND
per
IN
PART
OPENIAL
OR
RA
DIO
SIG.
RA
DIO
GN
D
FIR
GN E DEPT
D
MA
GN X OPEN
D
STRI
KE
GN
KEYPD
AD
GN
D
/ RD
PH
R
OTOC
GN
ELL
D
MA
X
MO
GATE
PST
ow
ATer
USIn
MO
GN
D
(-)
BATT
ER
IN US Y
E
POW
24V
GN
D
2
1
4
H
ER
M
BO ATRI
AR X
D
Lim
it SW
ge
MA
ON TRIX
-LI
NE
5
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
5
JO
M
LE AX
LE G
D ON
FT JO
RIGG
HT
E
Plu
3
13
12
5
SeERD
ns
itiv
ity
F
ER
D
M
Ove otor
rLoa
tte
ry
6
om
S.c
.U
ax
8
w.M
SE
FU
Ba
TE
ST
Ba
tte
ry
D
pu
t In
ec
Sel ge or
lta
Vo AC
5V
11 AC
0V
23
d
ON
/O
Ba FF
tte
ry Repla
Ba ce
tte
ry
g
LE
t
1615 14
4
1/2
3
OPEN
CO BA
CLOS MPACKTTERY
E
SW LIMIT
ITC
OP
EN
STOP
CLOS
E
CO
M
GATE
DISA
BLE
SE
GATEC
1
2
UL
AL
ALARARM 12
M V
RESERET
GN T
D
Y
PRIM ON-LITOR
NE
GATEARY
(+)
Ed
VIT
OVER
LOAD
NO
LIM
CLM
SW
AMOITTO
P SL ITC
IPPR H /
ING
LIM
SW IT
ON ITCH
-LINE
(+)
GN
D
(-)
ge
UL
NSITI
5V
11
oto
Ce
ll Ed
0 En
Con
tro trap
lle
r
E SE
TOR
ID PL
ERROUG
R
CLOS
E
M
AR
AL
-20
or
EDGE
EDGE
STOP
REVE
RS
R
TO S
O T
M PU
IN
Ph
PO
WER
Mot
ENTR
AP
OPEN
SPEE
D
8
R
S
MAX
GATE
MIN
MC
MOT
ION
OB
BLACD PORT
K BO
X
PHOT
OCEL
L
UL
MOT
PO
RECOSITION
RD
ER
24VD
C
D
GN
BL
A
Li CK
Se mit
nso
r
R -4
S 8
-4 5
8 (+
5
W G (- ) R N )
2 D 4 V
-
12VD
C
GN
D
g
LE
SAFE
TY
Y
CLOS
ID
PLUG
2
g
OP
RIGHEN
T
EN
ON
CENT
OP
LEFTEN
OP
Plu
PRIM
GATEARY
OP
1 TIMEN
E
TO
MA
TIC
E
CLOS E
ED
OPENE
AU
AN
TAIL TI
GATE
EXIT
3
BACKBATT
-UP ERY
LEAV MOD
LEAV
in US
A
P
MA
DE
WER
PO
AC
Mo
du
le
IN
PW
R
ErrorIN
7
ww
p
7 Am Amp
15
On
Off
AX
id
ro
To
L
I
M
I
T
M
G
NIN
AR
W
!
N!
TIO
TEN
AT
!
4
H
E
HIGAG
r
OLT he
V
nct
n
'bra ie
de avan
tret
l'en
S
E
N
S
O
R
H
E
HIGAG
LT ct
VOsconnefore
it
be
di
un
wer g
po icin
rv
se
6
GR
Li AY
Se mit
nso
r
7
10
inputs/outputs, loops and reports problems with gate
operator. See Matrix 1 Section starting on page 26.
Audible Alarm: Sounds when there is a problem with
cycling the gate. Push the alarm reset button on the
operator to shut off alarm (see below). Alarm can sound
every time operator is cycled using ONLY battery back-up
power when turned ON, See page 44.
24VDC Brushless Motor (6 million cycles)
Gate Shut-Off / Alarm Reset / Electronic Gate Open/Close:
Located on front of operator cover. See A, B, C below.
MAX MC-200 Motor Controller: Manages UL entrapment
protection devices and operator motor reversing ERD
sensitivity adjustment. See pages 18, 19, 20, 25, 27 & 37.
MAX Toroid 15 Amp Box: AC power management for the AC
input power to the gate operator. See pages 21, 22 & 25.
MAX BC-7 Battery Module: Battery Back-Up and DC power
management for the gate operator. See page 28.
11
9
8 Limit Sensors: Communicates gate cycling positions with
Matrix 1. See pages 32, 38 & 43.
9 Limit Sensor Activators (Magnets): MUST be mounted on
chain in the desired OPEN and CLOSE gate positions to
activate the limit sensors. LED will light when activated.
See page 38.
10 AC Power Gang Box: Input AC power wire connection. See
page 21.
11 Additional Gang Box: Single gang box to wire a GFCI outlet
for additional power outlets if desired. See page 21.
A
B
C
Gate Shut-Off / Alarm Reset /
Electronic Gate Open/Close
A Gate Shut-Off Switch: If turned ON, prevents any control devices
from operating gate when servicing operator. Only the Jog left, Jog
right buttons on MC-200 motor controller will operate gate. See
pages 34 and 41 for complete information about Gate Shut-Off
Switch functions.
B Alarm Reset Button: Push to shut off alarm and/or reset Matrix 1.
See pages 33, 39 & 44.
C Electronic Gate Open/Close: Electronically move the gate open or
closed by turning removable key. See page 43.
17
Wiring operator
Gate Operator System Overview continued
1 BATTERY Plug: MUST be plugged into BATTERY IN port Before use.
MAX BC-7 Battery Module
2 POWER/SOLAR IN Port: MAX Toroid 15 Amp Box connection.
3 Battery Voltage LEDs: Show amount of battery power available.
LEDs are always ON when using AC power. Test battery button must be
pressed to show battery power when using battery power ONLY.
R
WE
PO IN
RY
TTE K
BA PAC
R
TO ER
MO OLL
TO NTR
CO
L
/SO
ER IN
OW
WE
R/S
IN
OL
P
2
AR
tt
Ba
RY
TTE
BA IN
s.c
US
A
6
4
om
ax.u
w.m
ry
tte
Ba rror
E
T
ES
C-le7
X Bodu
MattAery M
ER
IN Y
To turn OFF ALL POWER to operator:
B
IN
ry
T ry
tte
e
Ba rror
ge
e Batt
lta
E
T
lac
Vo F
TES ry
ep
ry
e
ge R ery
ce Batt
lta F att
1/2
Vo N/OF B
pla
Re ery
ery O attFery
F
tt
tt
F
a
B
/O
Ba 1/2 B
ON ery
tt
E
Ba
IN
tte
Ba
E
TT
7
1. Turn OFF AC POWER Switch on MAX Toroid 15 Amp Box.
Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the RED ON/OFF BATTERY
button until MAX BC-7 LEDs turn ON, then release button.
LEDs will turn OFF.
5
1
IMPO
RT
in
de
Ma
ww
BA
ANT
co
“BA nnect to
TT
befo ERY IN
”
re u
se
4 ON/OFF Battery Button:
IMPORTANT: Battery power automatically turns ON when
MAX Toroid 15 Amp Box AC POWER Switch is turned ON.
C-le7
X Bodu
MAery M
AR
PO
-7
BC ule
X
MA Mod
ery
att
3
5 Replace Battery LED: Replace battery when lit.
B
6 TEST Battery Button: Press to show amount of battery power available when
using battery power ONLY (Battery voltage LEDs will light respectively).
7 Battery IN Error LED: Lights when there is a battery connection problem.
Make sure battery plug #1 is plugged into BATTERY IN port or there are no
damaged or loose wires.
MAX MC-200 Motor Controller
Continued on next 2 pages.
-
PW
R GND
12
V
-
-
P
)
(+ ) 85 (- -4 5 D
S -48 N R S G 4V
2
R
R
W
P
O
N
B
A
T
PA TE
C R
K Y
N
LY
L
S IM
W IT
se po
IT
C
n we
H
so r
M
A
rs en
L
C
A
-2
w tr
R
it ap
00
M
h m
P
M e
W
C n
-2 t
R
00 pr
12
o
V
P te
W c
M
R tio
U
S
12 n
T
V
be
us
ed
•A
o se
• W per ns
a o
M ire tor r M
op ON N W US
a e IT OR IL T
• R re u rato OR MA L N be
se r’s E L O w
e
b v
D L T ir
• M e w ers d. MC se Y C fun ed
i in
-2 ns L c to
p C re g
00 o O tio E
r S n D
• U ow -20 d to Ed
w sO E . G
e 0
A g
he N D
E
JU NU r M PW N e a
1
n LY (N
or
M SE ON R Y o nd
du , .C
P D I 1 f /o
al to .)
E i TO 2 th r
R n
V e P
op ea
E pu R M 3 ho
er ch
D t E U I t
s
D
a
o
n
or M
S p C
to
rs
fa U sen T b ut e
s ll
ul S
t w T sor e u . ca
S
ee
n
ill rem s. se
d
in
oc a
to
V st
cu i n
oi a
r lla
r.
la ti
no on
3 2
tic in
1
e str
d’ u
in ct
st io
al ns
la .
tio
n.
O
M
IN OT
P O
U R
T
S
M
u U
n S
u T
se j
d um
in p
p er
u
ts
3
Hit SW
Lim
2
1 ATRIXE
M IN
ge N-L
Ed O
G
K
F
G
JO HT
G RIG
JOFT
LE
C
D
3
4 5
B
D
ER
tor
Mo oad
rL
e
Ov
A
D
EsRitivity
Se
n
F INPUTS:
Jog LT/RT inputs: Can connect to an External Open/Close Key switch.
Connect a single key switch to control dual gate operators, See page 37.
GND input: Low Voltage Common connection.
I
r
0 lle
-20ontro
MoCtor C
M
G Matrix On Line LED: Gate operator is successfully communicating with
Matrix 1 when lit.
H Limit SW On Line LED: Limit Switch Sensors are successfully
communicating with MC-200 Motor Controller when lit.
I Edge 1 LED: Reversing Edge 1 input has been activated when lit.
J Edge 2 LED: Reversing Edge 2 input has been activated when lit.
K UL Entrap LED: Edge1/Edge2/Photocell input has been activated when lit.
L Photocell LED: Photocell input has been activated when lit.
M Power LED: Low voltage power is connected when lit.
N RS-485 Input: Factory wired for Primary operator.
Wire to Matrix 1 “SEC GATE” for Secondary operator ONLY.
O 24V Power Input: 24V Power for Matrix 1 ONLY.
P 12V Entrapment Protection Sensor Power Out: 12V Power that ALL
Entrapment protection sensors MUST use PWR 12V power.
DUAL GATE OPERATORS NOTE: Connect EACH photocell/sensing
edge to the corresponding gate operator’s MC-200. See page 10.
18
E Jog LEFT/RIGHT Buttons:
Push and HOLD buttons accordingly to move the gate (release the button to
stop gate). WARNING: Avoid moving gate while using Jog buttons.
Entrapment Protection Sensor Inputs
UL p
tra
En
2
In
er
w
P
o
R
M
3
w ON
le ire IT
a d O
2. jum rne to R
R p d in ED
e e . p
3. be ve red An uts Se 2
P w rs . y B n
in
s
r
un E o
bu es ire g
us FO rs 3
un tto s a d to Ed
ed R M
til ns nd e ge
U
in E t S
be a H ith a
pu h T
ep t th O er nd
ts ey be
L
is e s D inp /or
M ca
he a th ut P
U n
m e 2 ho
S b
a
T e
M
r d e t O o to
Le
O
be
T
, le im PE r 3 C
ar
O
b
R
4. y n O
ar e o N . ell
M
LE be m P
O
n n &
ca
T
IO
se D ep od EN
m M S
n
N
od a TO
fo ns s W ing e
S
t
la
r
e i P
r o
. s T
be x
5. op BO r o ILL
ts OP
1
P er T n b
g
fo
in
C
to res ato H MC e
r
s.
5 LOS
be le s S rs MC -2 ON
m
E
in
In ep arn TO are -2 00 fo
. in
pu in s P u 00 . L r
ts g en b se s E ea
dic
ar sto so ut d. wh Ds ch
at
e p rs ton
en W de
ed
n o s. a a
t
I
du LL ec
nd g
w
al b te
M
en ain
e d
O
d w
O
N
le ith
N
IT
ar in
O
n 5
R
m m
E
D
od in
.
e, .
1.
R
WE
PO
E
1
3 2
14 1 1
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
L
ll
Ce
oto
Ph
Jdge
E
-
ND
1
15
16
X
MAON
D
LE
-
ge
Ph
E
oto dge
Ce 2
ll
n
ctio
ote
Pr
nt
me s:
ap put
r
t
En In
M
J
J og
G og RT LT
-
Ed
:
N:
IO ION
T
UT
CA TTEN
A
e
d
ore to
nit Pho Cell
Mo
OR
lid
d
ore g
nit rsin ge
Mo eve Ed
R
S
T
O
C ERD Sensitivity Knob: 16 selectable sensitivity settings of ERD sensor.
D ERD Sensitivity LED: MAX sensitivity reached when lit.
GND
00
O
B ERD LED: ERD sensor has been activated when lit.
n
ctio s
ote ne
Pr eli
nt uid
meor G
p
a
tr ns
En Se
-2
C
M
A MOTOR OVERLOAD LED: Excessive current being drawn by motor when lit.
1
M
D”
E
RN
EA
“L
be
:
ST rs.
&
MUenso
& R s puts
O
in
uts NIT N
Inp MO EAR
to o L
T
2
IX
TR
MA
Edge 1-MONITORED CLOSING direction ONLY input: Connects to a
NORMALLY CLOSED (N.C.) Sensing Edge or Photocell.
Closing direction activation: gate will reverse to full open position and
reset close timer.
Opening direction activation: gate will NOT be monitored during
opening cycle.
Edge 2-LEARNED MONITORED OPENING/CLOSING direction input:
Connects to a NORMALLY CLOSED (N.C.) Sensing Edge or Photocell.
Input MUST be “LEARNED” before it can MONITOR a connected sensor
(see page 20).
Closing direction activation: gate will REVERSE to full open position but
will NOT reset close timer. Another command is required for gate to
resume operation.
Opening direction activation: gate will REVERSE 2 inches and STOP.
Another command is required for gate to resume operation.
Photo Cell-LEARNED MONITORED OPENING/CLOSING direction input:
Connects to a NORMALLY CLOSED (N.C.) Sensing Edge or Photocell.
Input MUST be “LEARNED” before it can MONITOR a connected sensor
(see page 20).
Closing direction activation: gate will STOP. Another command is
required for gate to resume operation.
Opening direction activation: gate will STOP. Another command is
required for gate to resume operation.
Wiring operator
entrapment protection wiring
PhotoCell Edge Limit SW
2
1
POWER
3 2 1
3
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
MC-200
ERD
LED ON
Edge MATRIX
UL
ON-LINE
Entrap
Motor Controller
Jumper UNUSED Entrapment Protection
Inputs or a fault will occur.
15 14 13
16
12
MAX
4
JOG JOG
LEFT RIGHT
Motor
OverLoad
5
ERD
Normally Closed (N.C.)
3
Sensitivity
2
Sensor Wire
1
GND
Example: Inputs 2
& 3 are NOT used
and MUST be
jumpered to GND.
Photo Cell: LEARNED MONITORED OPEN/CLOSE
Edge 2: LEARNED MONITORED OPEN/CLOSE
Typical Wiring For:
EDGE 1: MONITORED CLOSE ONLY
a 10K Normally Closed (N.C.) Sensing Edge...... AND/OR ........ a Normally Closed (N.C.) Photo Cell
10K Edge
Normally
Closed
A
IMPORTANT Sensing devices MUST be powered by
MC-200 or they will NOT be MONITORED.
Re
Th
cr
ru-
GEM - 104
ON = Obstruction
BLINKING = Fault
MON.
PWR
SAFETY
INPUT
Power
PWR 12V
Polarity does NOT matter
PWR 12V
LY
se po
n we
so r
A
rs en
L
A
w tr
R
it ap
M
h m
M e
W
C n
-2 t
R
00 pr
12
o
V
P te
W c
M
R tio
U
S
12 n
T
V
be
u
E sed
n
A
t
op se S ra
p
e n
W ra so en m
M
M ire tor r M so en
A
op ON N W US r t
T
R
ar er IT OR ILL T Gu Pr
IX
b
o
a
O
e
M
R u tor R A NO e w ide te
1
s
E
be ev ed ’s D LL T ire li ct
e
. MC s Y fu d ne io
e
M wir rsin
-2 ns CL nc to s n
ti
po C- ed g
O
E
0
E
0 ors S on D
w 2
w O E . G
U e 00 to A dg
he N D
E
r
N
e
P
JU U M W N a
1
n LY (N
or
M SE ON R Y o nd
du , .C
P D IT 1 f /o
to
.)
al
E in O 2 th r
R
V
P
op ea
E pu R M e 3 ho
er ch
D ts E U In to
ato
or M D S p C
rs
fa U sen T b uts e
ll
ult S
T so e . ca
S
w re rs us
ee
n
ill m . e
d
in
oc a
to
V sta
cu in
oir
ll
r.
la ati
no on
3 2
tic in
1
e str
d’i u
ns cti
ta on
lla s.
tio
n.
P
s: t
M
IN OT
P O
U R
T
S
O
N
00
P
In
M
C
-2
o
w
er
P
R
T
O
O
M
2
N
Edg O
R
WE
PO
Wireless Module
0
-20ontro
MCtor C
IN
OS
Polarity does NOT matter
To MC-200 Power
To GND
To Edge 1
To GND
To Edge 2 or Photo Cell
Wall
Wireless
Module
Gate Closed
CLOSING direction
10K NORMALLY CLOSED
Sensing Edge Wirelessly
to Edge 1
OPENING direction10K NORMALLY CLOSED Sensing Edge
Wirelessly to Edge 2 or Photo Cell
NORMALLY CLOSED OPENING direction Photocell
IMPORTANT: Photocells MUST
to Edge 2 or Photo Cell
GEM - 104
ON = Obstruction
BLINKING = Fault
MON.
PWR
SAFETY
INPUT
Opening
direction
Sensing
Edge
To GND
10K Edge
Normally
Closed
MG
L-T
Mo X2
nit 0
Ga ore
te d
Lin
k
Mil
lerE
Opening
direction
Sensing
Edge
(Wireless)
Opening direction
10K Sensing Edge
to Edge 2 or Photo Cell
To GEM-104
To GEM-104
Closing direction
Sensing
Edge
To GEM-104
To Edge 1, Edge 2, Photo Cell
This Module MUST be used with EACH
Normally Closed 10K type Sensing Edge.
Self-Supporting Post Wiring
A
To GEM-104
be in alignment or fault will occur.
Gate Edge Module (GEM-104)
To MC-200 Power
C)
.)
N.CLY
tor
(
flec
Re
E 1n ON
G
ED ctio
IMPORTANT: Photocells MUST
ire
be in alignment or fault will occur.
GD
Mo
CL
Re
fle
Be ctive
am
D(
GN
ller
To MC-200 Power
D
ER
tor
Mo oad
erL
Ov
D
EsiRtivity
UL p
ra
Ent
OPENING direction 10K
NORMALLY CLOSED Sensing Edge
to Edge 2 or Photo Cell
Wireless
Module
Lim
IX
TR E
MA-LIN
14 1312
4 5
Sen
G
JO HT
G RIG
JOFT
LE
P
s: t
R
T
O
1.
M
3
w ON
le ire IT
a d O
2. jum rne to R
R p d in ED
e e . p
3. be ve red An uts Se 2
P w rs . y B n
in
un E so 3
bu res ire g
us FO rs
un tto s a d to Ed
ed R M
til ns nd e ge
U
in E th S
be a H ith a
T
pu
ep t th O er nd
ts ey be
L
is e s D inp /or
M ca
he a th ut P
U n
S b
ard me e O 2 ho
T e
Le
o to
be
, le tim PE r 3 C
a
4. by rn O
arn e o N . ell
LE be m P
ca
n &
se D ep od EN
m M S
n
s
T
od a O
fo ns W ing e
S
e trix P
r o
. las TO
be
5. op BO r o ILL
ts
1
P
P era T n b
g
fo
in
C
to res to H MC e
r
s.
5 LOS
be le s S rs MC -2 ON
m
E
a
a
0
in
In ep rn TO re -2 0 fo
. in
pu in s P u 00 . L r
ts g en b se s E ea
dic
are sto so utt d. wh Ds ch
ate
p rs o
en W de
d
no s. a n a
du ILL tec
nd g
w
E
al b te
M
en ain
n
e d
O
tr
d w
O
N
le ith
N
a
IT
arn in
O
In pm
R
m 5m
E
p e
D
od in
u n
.
e, .
t
P
M
C
-2
o
w
er
00
In
O
N
M r
u U ot
n S e
u T c
se ju t
d m io
in p n
p er
u
ts
3
2
2
1
e
3
D
M r
u U ot
n S e
u T c
se ju t
d m io
in p n
p er
u
ts
3
2
LY
se po
n we
so r
A
rs en
L
A
w tr
R
it ap
M
h m
P
M e
W
C n
-2 t
R
00 pr
12
o
V
P te
W c
M
R tio
U
S
12 n
T
V
be
u
E sed
n
A
t
op se S ra
p
e n
W ra so en m
M
M ire tor r M so en
A
op ON N W US r t
T
R
ar er IT OR ILL T Gu Pr
IX
b
o
e a O M
R u tor R A NO e w ide te
1
s
E
be ev ed ’s D LL T ire li ct
e
. MC s Y fu d ne io
e
M wir rsin
-2 ns CL nc to s n
po C- ed g
00 o O tio E
E
r S n D
w 2
w sO E . G
U e 00 to A dg
he N D
E
JU NU r M PW N e a
1
n LY (N
or
M SE ON R Y o nd
du , .C
P D IT 1 f /o
al to .)
E in O 2 th r
R
V
P
op ea
E pu R M e 3 ho
er ch
D ts E U In to
ato
or M D S p C
rs
fa U sen T b uts e
ll
ult S
T so e . ca
S
w re rs us
ee
n
ill m . e
d
in
oc a
to
V sta
in
cu
oir
ll
r.
la ati
o
no n
3 2
tic in
1
e str
d’i u
ns cti
ta on
lla s.
tio
n.
-
M
IN OT
P O
U R
T
S
PW
R G
O
R
12 ND - VRS S-48
-48 5 (+
5 (- ) R 2 GND ) 4V -
PW
-
M
R G
2
PW
1.
M
3
w ON
le ire IT
a d O
2. jum rne to R
R p d in ED
e e . p
3. be ve red An uts Se 2
P w rs . y B n
in
un E so 3
bu res ire g
us FO rs
un tto s a d to Ed
ed R M
til ns nd e ge
U
in E th S
be a H ith a
T
pu
ep t th O er nd
ts ey be
L
is e s D inp /or
M ca
he a th ut P
U n
S b
ard me e O 2 ho
T e
Le
o to
be
, le tim PE r 3 C
a
4. by rn O
arn e o N . ell
LE be m P
&
ca
n
E
se D ep od N
m M S
n
od a TO
fo ns s W ing e
S
e trix P
r o
. las TO
b
5. op BO r o ILL
ts
eg 1
P era T n b
fo P
in
C
to res to H MC e
r
s.
5 LOS
be le s S rs MC -2 ON
m
E
in
In ep arn TO are -2 00 fo
. in
pu in s P u 00 . L r
ts g en b se s E ea
dic
are sto so utt d. wh Ds ch
ate
p rs o
en W de
d
no s. a n a
du IL tec
nd g
w
E
al L b te
M
en ain
n
e d
O
tr
d w
O
N
le ith
N
a
IT
arn in
O
In pm
R
m 5m
E
p e
D
od in
u n
.
e, .
t
R
12 ND - VRS S-48
-48 5 (+
5
GN (-) ) 24 D - VEdg
15
16
X
MAON
LE
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
ell
Pho
e
ell
W
it S
e
toC
To GEM-104
NORMALLY CLOSED
CLOSING direction
Photocell
C
To GEM-104
2
CL
:
N:
IO ION
T
UT
CA TTEN
A
1
e
IN
OS
to
(C)
Ed GN
ge D
1
g
r
Mo
•
-
4 5
D
EsiRtivity
N
TIO
.)
N.CLY
(
1 N
GE O
ED ction
ire
Polarity does NOT matter
GD
UL p
ra
Ent
0 lle
-20ontro
MCtor C
R MO
TO
MO
Sen
D
GN
:
d
IX
TR E
MA
e N-LIN
Edg O
E
“L
be
ST s.
MU nsor &
& R se puts
O
ts NIT N in
Inpu MO AR
LE
to
To
o
h
W
D
ER
tor
Mo oad
erL
Ov
E
it S
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Lim
3
D
14 1312
P
ell
C
2
2
1
X
MAON
LE
G
JO HT
G RIG
JOFT
LE
1
e
to
g
PO
e
15
16
•
red
•
OR onitoPhotoCell
M
LT g T Jo g R
Jo
d
o
h
E
Pho
R
WE
Edg
:
N:
IO ION
T
UT
CA TTEN
A
lid
•
-
Ed GN
ge D
1
P
ell
e
R MO
toC
lid
•
LT g T Jo g R
Jo
TO
S
d
ore to
nit Pho Cell
N
TIO
MO
00
Mo
•
d
ore g
nit rsin ge
Mo eve Ed
R
”
ED
S
-2
•
OR
N
AR
00
C
d
ore g
nit rsin ge
Mo eve Ed
R
”
ED
RN
EA
“L
be
:
ST s.
MU nsor &
& R se puts
O
ts NIT N in
Inpu MO AR
LE
to
To
GND
•
-2
M
•
C
GND
•
See next page for a specific
photocell’s N.C.- N.O. input.
IT
LIM ITCH
SW
M
Y
ER
TT
BA PACK
Y
ER
TT
BA PACK
IT
LIM ITCH
SW
Power
R
GND
PW
Polarity does NOT matter
To
Normally Closed
10K Sensing Edge
am
Power Trans
GND
GEM-104
Be
Closing direction
10K Sensing Edge
to Edge 1
A
Gate Closed
Wireless
Module
dge
Opening direction
10K Sensing
Edge wirelessly
to Edge 2
or Photo Cell
DUAL GATE OPERATORS NOTE: Connect EACH photocell/sensing edge to the corresponding gate operator. See page 10.
19
Wiring operator
PhotoCell Edge Limit SW
2
1
POWER
Edge MATRIX
UL
ON-LINE
Entrap
Motor Controller
1
15 14 13
16
12
MAX
ERD
LED ON
3
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
MC-200
3 2
4
JOG JOG
LEFT RIGHT
5
ERD
Motor
OverLoad
Sensitivity
EDGE 1 Note: CLOSING direction ONLY.
Inputs 2 & 3 MUST be “LEARNED” to MONITOR OPENING/CLOSING direction sensors.
To LEARN inputs 2 & 3 :
1. MONITORED Sensors MUST be wired to inputs BEFORE they can be learned.
Any unused inputs MUST be jumpered, see previous page.
MATRIX 1
2. A Sensing Edge or Photo Cell can be wired to either input 2 or 3.
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
3. Press and HOLD the STOP button & then the OPEN button
together on Matrix 1 until beep is heard, learn mode begins.
NOTE: DO NOT press the OPEN button before the
STOP button or learn mode will NOT function.
MOTOR MOTION
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
OPEN STOP
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
CLOSE
GND
STOP
OPEN
POSITION
RECORDER
12VDC
MAX
GATE SPEED
OBD PORT
BLACK BOX
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
LIMIT
SWITCH
ON-LINE
MAX
Example shows that sensors
LED ON
are DETECTED on inputs
JOG JOG
RIGHT
LEFT Cell.
Edge 2 and Photo
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSEE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
ORDER
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
BATTERY
IN USE
POWER
24V
GND
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
GND
RADIO SIG.
5. Press STOP button again within 5 min. to learn sensors and
MOTOR MOTION
end learn mode, beeping stops.
Wired Inputs are now MONITORED.
OPEN STOP CLOSE
If STOP button is not pressed within 5 min. learn mode terminates.
If no sensors are detected then factory default setting (Edge 2 and
Photo Cell are NOT Monitored) is restored.
OPEN
LEFT
OPEN
1 TIME
(+)
GND
(-)
4. LEDs WILL be ON for each detected sensor on MC-200.
Limit SW
PhotoCell
PhotoCe
hotoC
oto el
otoC
elllll Edge
Ed
LEDs WILL be ON for BOTH MC-200s when dual operators
2
are used. If an LED is not on and it should be, wiring to
1
POWER
R
Edge MATRIX
UL
sensor is bad, photocells are out of alignment, photocells
ON-LINE
Entrap
MC-200
Motor Controller
are wired wrong - N.C. or N.O. depending on which
photocells are used (see below) or sensor is bad etc. and
must be corrected. When all LEDs are ON that should be ON, proceed to next step.
RADIO GND
RADIO SIG.
GND
UL 325 2016 Compliant MONITORED Normally Closed Entrapment Protection Devices:
Normally Closed Definition: When Power is off, relay contacts are OPEN. When Power is on, relay contacts are CLOSED.
Photo Cells:
Model RG Miller Edge Reflecti-GUARD Reflective-Beam Type (Normally Closed)
Model PG Miller Edge Prime-GUARD Thru-Beam Type with battery operated transmitter (Normally Closed)
Model EMX-IRB-MON EMX Thru-Beam Type (Normally Closed)
Model EMX-IRB-RET EMX Reflective-Beam Type (MUST be wired to Normally Open)
Model E3K-R10K4-NR OMRON Photo Electric Sensor Reflective-Beam Type (MUST be wired to Normally Open) will work with 12V
Model 60-2728-1 Allen Bradley Reflective-Beam Type (MUST be wired to Normally Open)
Direct-wired 10K Sensing Edge:
Model 10K Sensing Edge with GEM-104 Module Miller Edge (Normally Closed)
MAX 10K Mini Edge Maximum Controls (Normally Closed) Requires a Miller Edge GEM-104 module
MAX 10K Edge 1 Maximum Controls (Normally Closed) Requires a Miller Edge GEM-104 module
Sensing Edge Wireless Transmitter/Receiver:
Model MGL-K20 Miller Edge Monitored Gate Link Transmitter and Receiver
20
15 14
16
3
4
5
ERD
Sensitiv
Wiring operator
high voltage input ac power
Choose either 115V or 230V setting on input AC power selector switch.
DO NOT TURN OPERATOR
POWER ON AT THIS TIME.
Wire desired input AC power wire to power terminal. A additional single gang box
is provided to install power outlets if desired. GFCI outlet type is recommended.
NOTE: AC power wire is required for EACH gate operator when using dual gate
operators.
MAT
RIX
1
MA
DE
LEA
OPENVE
TO
MAT
IC
EXI
AN
TAILG TI
ATE
T
SED
OP
LEFTEN
EXIT
OFF
TER
PRIM
GATEARY
OP
1 TIMEN
E
OP
EN
ON
CEN
CAUTION: MAKE SURE CIRCUIT BREAKER IS
OFF AT AC POWER SOURCE BEFORE WIRING
BACKBATT
-UP ERY
LEA MODE
CLO VE
in US
A
AU
/CLO
SE
C
OP
RIG EN
HT
OFF
ON
CENT
ER
SAF
ETY
TR
OLS
SAFE
MA
GL
DELAOCK
Y
1.5
Sec
2Se
MA
LOCKG
c
COM
NC
TY
MIN
GA
TAMP TE
ER
OFF MAX
CLOS
E TIM
ER
ID
PLUG
Tamp
er NO
COM
Tamp GND
er IN
PART
OPENIAL
MO
PO
RECOSITIO
RD N
ER
OB
BLACD PORT
K BO
X
MA
X
GATE
RA
DIO
SIG
.
RA
DIO
GN
D
FIR
GN E DEPT
D
MA
GN X OPEN
D
STRIK
GN
E
KEYPD
AD
GN
D
/ RD
PH
R
OTOC
GN
ELL
D
MIN
UL
R MO
OVERL
NO
OAD
LIM
CLA IT SW
MP
SLI ITCH
PPI /
NG
In
(+)
GN
D
(-)
24V
GN
D
(+)
GN
D
(-)
SEC
GAT
E
ge
MO
INP TO OPEN
UT R
S CO
BAT
CLOS MPAC TERY
E K SWITCLIM
BATT
ER
IN US Y
E
IT
H
AL
AR
M
POW
ER
IX
R D
AT R
M OA
B
Lim
it SW
2
1
AC Power
Gang Box
er
Ed
GA
STAT TE
US
E
Power Terminal Wires
Line (Black)
Neutral (White)
Chassis (Green)
1
2
w
Po
ll Ed
Y
R
LIM
SW IT
ON ITCH
-LINE
MO
PRIMA ON-LITOR
NE
GAT RY
OCEL
L
EDGE
ID PL
ERROUG
R
UL
AL
ALARARM 12
M V
RESERET
GN T
D
CLOS
E
SIT
IVIT
TO
O
DANGER
HIGH VOLTAGE!
ge
MA
ON TRIX
-LI
NE
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
JO
M
LE AX
LE G
D ON
FT JO
RI G
GH
T
E
1615 14
3
13
12
4
5
1/2
SeERD
ns
itiv
ity
F
ER
D
Mo
Ov tor
erLo
ad
V
115
Ce
r Co EnUL
ntro trap
lle
r
ENTR
AP
N
EDGE
ERS
E SEN
MO
TOR
oto
W
MC ER
Mo -2
to 00
TIO
STOP
REV
D
M
Ph
PO
TO
OPEN
SPEE
MAX
OP
EN
STOP
CLOS
E
CO
M
GATE
DIS
ABLE
24V
DC
GN
D
PHOT
R
S
R -4
S 8
-4 5
8 (+
P
5
W G (- ) R N )
2 D 4 V
-
12V
DC
GN
D
/OF
Ba F
tter Re
y
pla
Ba ce
tter
y
t
Inpu
lect
Se ge or
lta
Vo AC
5V
11 AC
0V
23
SE
FU
ON
Ba
TE
ST
Ba
tter
y
tte
ry
Mo
du
IN
On
Off
MA
G
NIN
AR
W
!
AT
N!
TIO
TEN
!
H
E
HIGAG
LT r
VO rancthe
V
H
E
HIGAG
OLT nect
on fore
discr be unit
we g
po icin
rv
se
ax
w.M
ww
co
Power
Terminal
m
S.
.U
WER
PO
AC
le
PW
R
Err IN
or
X
p
7 Am Amp
15
id
ro
To
IMPORTANT NOTE: Make
sure there are NO exposed
bare wires at the power
terminal connection.
NG
NI
AR
W
!
GH E
HI AG
LT ect
VO connefore
L
I
M
I
T
S
E
N
S
O
R
dis r b unit
we g
po icin
rv
se
Connect to input
AC power wire.
n
'b
de avantie
ntre
l'e
Input AC Power Options
Single Phase 115VAC Only
Single Phase 230VAC Only
115VAC
230VAC
K
GLOC
MA LAY
DE
ARY
PRIM TE
GA
ERY DE
BATT P MO
-U
BACK
1
RIX
MAT
MA
DE
VE
LEA SED
CLO
VE
LEA N
OPE
in USA
ATIC
OPE
M
TO
AU
TI
AN
TAILG
1.5S
ec
2Se
COM
NC
G
MA
LOCK
c
OFF
NO
per
Tam COM
D
GN
IN
per
Tam
EN
OP HT
RIG
EN
OP T
LEF
N
OPE E
1 TIM
SE
LO
N/C
NTR
CO
GATE ER
TAMP
OLS
TY
SAFE
L
OCEL
PHOT
1
EDGE
ER
CENT
EXIT
EDGE
UL
ATE
V
M 12 T
ALAR M RE
UL ALAR RESETD
GN
ON
T
N
MAX
E
CLOS
TIM
STOP
L
TIA
PAR EN
OP
OPEN
X
DC
M
IN OTO
PU
R
TS
er
o
w
P
O
T
O
R
M
ERS
NO
MAX
ERY
BATT USE
IN
RY
MA
PRI E
GAT
SEC E
GAT
3
M
Pho
R
WE
PO
toC
ell
e
Edg
it SW
Lim
2
1 TRIXE
MA-LIN
e
Edg ON
UL
rap
Ent
er
-200ntroll
MCtor Co
ter
Bat
Mo
T
y
F
E
R
POWE
15
16
X
MAON
LED
G
JO T
G RIGH
JOFT
LE
1/2
L
I
M
I
T
E
CLOS
GATEUS
STAT
IT
LIMITCH
SW -LINE
ON
TOR
MO -LINE
ON
AL
AR
GND
Y
IVIT
SIT
AD
RLO
OVE
H/
ITC NG
IT SW PPI
LIM SLI
MP
CLA
E SEN
TOR
MO
.
SIG
DIO
RA
D
GN
DIO
RA
PT
E DE
FIR
D
GN X OPEN
MA
D
GN
IKE
R
STR D
/ RD
GN PAD
KEY D
ELL
GN
OTOC
PH
D
GN
IT H
LIM ITC
Y SWDC
TER K 24V
BAT PAC
12
REV
D
SPEE
MIN
PORT X
OBD CK BO
BLA
GND
W
c
lig to onn AR
htn gro ec
N
ing un t ch ING
prod ro ass
te d fo is
cti r
on
GATE
)
(+ ) 85 (- -4
D
S 85 N R S-4 G V
24
M R
R
B AT
W
O R
A IX P
R
D
MA
ION
POSITRDER
RECO
12V
OPEN
COM
E
CLOS
ER
ID
PLUG
(+)
GND
(-)
MIN OFF
ETY
SAF
(+)
GND
(-)
Ground
within 10 ft
of operator.
34
14 1312
ER
D
tor
Mo oad
erL
Ov
5
D
ERtivity
Se
nsi
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Proper grounding of this gate operator is a
WARNING
requirement for LIGHTNING PROTECTION
connect chassis
in lightning prone areas. To be effective,
to ground rod for
ground connections should be made with a
lightning protection
minimum 12 AWG, 600 volt insulated wire
to a ground point within 10 feet of the gate operator. The ground
point must be at an electrical panel, a metallic cold water pipe that
runs in the earth, or a grounding rod.
TIO
R MO
TO
MO
TER
CEN
In
Any of the THREE Chassis Grounds can be used. They are located
next to the gear reducer. DO NOT remove any existing green
ground wires.
EXI
2
UG
ID PLROR
ER
RAP
ENT
OFF
24V
D
GN
Operator MUST
be Properly GROUNDED
EN
OP P
STO SE
CLO
ABLE
M
CO
DIS
GATE
GFCI Outlet
NOT provided
115V
Additional
Gang Box
CAUTION: If power selector
switch is set for 115V but
input power is actually 230V,
7 Amp Fuse will blow.
230V
Additional single gang box provided.
Wire GFCI outlet to the input AC wire
BEFORE connecting to operator power
terminal if power outlets are desired.
ce
pla y
F Re ter
/OF Bat
ON tery
Bat
TES
ter
Bat
e
dul
y Mo
y IN
ter
Bat or
Err
S
E
N
S
O
R
Grounding Rod
NOTE: Consult city codes for AC line wiring.
Beware of existing underground services.
21
Wiring operator
low voltage remote power supply kit - optional
A MAX Magic Box Kit (sold separately) is required to remotely install a MAX Toroid 15 Amp box at the AC power source.
Plug in Remote Toroid 15 Amp connector to Power In at MAX Magic Box. Wire input AC power to the Toroid 15 Amp box.
Choose either 115V or 230V setting on input AC power selector switch. Run 24V low voltage wires (not included) from the
MAX Magic Box connection to the gate operator and wire to POWER/SOLAR IN connector (Polarity Matters!).
Remove the MAX Toroid 15 Amp connector from the BC-7 battery module POWER/SOLAR IN port. Plug the Magic Box
POWER/SOLAR IN connector into the POWER/SOLAR IN port.
At MAX Magic Box
NOTE: A MAX Magic Box kit is required for EACH gate operator
when using dual gate operators.
DO NOT TURN POWER
ON AT THIS TIME.
DANGER
HIGH VOLTAGE!
Tor Rem
oi ot
Po
we
Co d 15 e
r In
nne Am
cto p
r
d
s+
Input AC Power Selector Switch
CAUTION: If power selector switch is
set for 115V but input power is actually
230 V, 7 Amp Fuse will blow.
IMPORTANT NOTE: Maximum Control’s remote
power supply technology does NOT utilize the
battery power from the MAX BC-7 Battery
Module during NORMAL gate operation.
Battery power is reserved for back-up power
ONLY when an AC power failure occurs. As a
result, battery life is NOT shortened.
This low voltage system can CONTINUOUSLY
cycle the gate during NORMAL gate operation,
perfect for high traffic gate applications.
22
.U
ax
w.M
B
att
P er
ac y
k
C
m
o
S.c
ww
R
-7
BCule
AXry Mod
Mtte
A
POWER/SOLAR IN
Connector
(Included in kit).
T
O O
N M
T O
R T
O O
L R
L
E
R
P
O
W
IN ER
POWER/SOLAR IN
Port
L
r
PO
WE
R
E
R
/S
IN O
CAUTION: MAKE SURE CIRCUIT
BREAKER IS OFF AT POWER
SOURCE BEFORE WIRING
115
VA
Inp 230 VC or
ut AC
AC
Po
we
/SO
IN LAR
Ba
Y
NOTE: Consult city codes for AC line wiring.
IMPORTANT: MAX Magic Box and Gate Operator
MUST EACH be Properly GROUNDED. Proper
grounding is a requirement for LIGHTNING
PROTECTION in lightning prone areas. To be
effective, ground connections should be made
with a minimum 12 AWG, 600 volt insulated
wire to a ground point within 10 feet of the MAX
Magic Box and gate operator. The ground point
must be at an electrical panel, a metallic cold
water pipe that runs in the earth, or a grounding
rod.
NOTE: Beware of existing underground services.
P
O
W
ut
Inp
MAX Magic Box MUST be
Properly GROUNDED
T
T
E
IN R
er
ow
P
AC
Low Voltage
wa
VOrran
if IDEty
l
RE abe D
MO l is
VE
D
V
24es
r
Wi WG
A
10 imum
n
i
M
To Operator
24 VDC
c
11 t In
5V pu
AC t
or Vol
23 tag
0V e
AC :
High Voltage
le
ox
-7
BCule
AXry Mod
Mtte
A
pB
Grounding Rod
Po
230V
Se
Input Power
Power Terminal
Wires
Line (Black)
Neutral (White)
Chassis (Green)
PO ON
OF WER
F
ow nn
se er ect
rvic be
ing fore
un
it
Am
D
un
AC
W
AR
NI
NG
!
H
VO IGH
LT
dis A
p co G E
15
Gro
IN
id
GN
B
SA
U
in
e
ad
M
Tor
o
7 A FUSE
MP
te
ST
TE ry
Pos +
IMPO
R
M
mo
TANT
co
“BAT nnect to
TE
befo RY IN
re us ”
e
PO AX
WE
R S PS-2
UP
PLY 4
Re
Ground
within 10 ft
of Box
BA
TT
ER
IN Y
tte
tage
lace Ba
Vol F
Rep ry
tery
tageFF Batte
Bat 1/2
lace
Vol N/O
F ry
Rep ry
E
tery O tte
tte
/OFF Ba
Bat 1/2 Ba
ON ry
tte
E
Ba
GND
r
Ba
IN
ST
TE ry
tte
Ba
ry
tte
Ba ror
Er
IN
C-7
X B odule
A
M M
ery
att
Polarity Matters!
2
in 4V L
Co ow
ndu Vo
it t lta
o G ge
ate Wir
Op e
era
to
ry
tte
Ba ror
Er
B
At Gate Operator
Wiring operator
solar power connection - optional
Refer to Solar application guide.
B
at
P ter
ac y
k
T
O
T MO
R T
O O
L R
L
E
R
N
w.M
ww
R
C-le7
X Bodu
MattAery M
R
/S
IN O
L
A
PO
W
E
WE
RT
IMPO
B
E
IN R
Y
T
A
B
AR
C-le7
X Bodu
MattAery M
T
P
OL
ANT
co
“BA nnect to
TT
befo ERY IN
”
re u
se
IN
O
R/S
Power/Solar
Plug
Pos + Red
m
O
.co
.US
ax
C
NOTE: Cover solar panel from
sunlight BEFORE wiring plug to
solar panel to prevent a shock
from occurring.
P
O
W
IN ER
POWER/SOLAR IN
Port
BA
TT
ER
IN Y
BIN
ry
tte
Ba rror
IN
E
ST
ry
TE ry
tte
e
Ba rror
ge
e Batt
lta
E
ST
lac
E
Vo F
p
T
e
ry
ery
ge R ery
tte
ce Batt
lta F att
Ba 1/2
Vo N/OF B
pla
Re ery
ery O attFery
F
E
tt
tt
F
a
B
/O
Ba 1/2 B
ON ery
tt
E
Ba
C-7
X B odule
A
M M
ry
tte
Ba
Polarity Matters!
GND Black
Max Solar
Power Kit
(Sold separately)
Remove the MAX Toroid 15 Amp connector from the
BC-7 battery module POWER/SOLAR IN port. Connect
the power/solar plug into the POWER/SOLAR IN port.
23
Wiring operator
secondary operator to matrix 1
Primary/Single
Gate Operator
Matrix 1
Unplug 4-Pin plug from the back of the
MAX MC-200 motor controller and connect
RS-485 wires as shown below.
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
SAFETY
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
O
T
O
M
R
In
IN
PW
R
Er IN
ror
!
N!
TIO
TEN
AT
!
H
E
HIGAG
LT r
VO nche
H
E
HIGAG
LT ct
VOsconnefore
be it
di
un
wer g
po icin
rv
se
ax
.U
S.c
(+)
GND
(-)
om
p
7 Am Amp
15
On
Off
G
NIN
AR
W
SE
X
MA
id
ro
To
L
I
M
I
T
S
E
N
S
O
R
'bra t
de avantien
ntre
l'e
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
(+)
GND
(-)
V
le
(+)
GND
(-)
115
D
GN e 1
Edg
du
w.M
ww
WER
PO
AC
Mo
Vo AC
5V
11 AC
0V
23
22 AWG Min. 3-conductor
twisted pair, shielded cable
3 Wires to Matrix 1
Secondary
Operator
MAX MC-200
Secondary
3 Wires to Matrix 1
24
RS-485 (+) RS-485 (-) GND PWR 24V -
ALARM
BATTERY LIMIT
PACK SWITCH
GND -
MOTOR
INPUTS
PWR 12V -
Power In
not used -
MOTOR
not used -
NO 24V
to Matrix 1
MATRIX
BOARD
Connect (3) three RS-485 wires from the SECONDARY operator’s
MAX MC-200 motor controller to the Matrix 1 - SEC GATE.
DO NOT connect PWR 24V.
Primary/Single
24V
GND
(+)
GND
(-)
1
ry
FIRE DEPT
GND
IX
tte
RADIO GND
RADIO SIG.
R
t
Inpu
lect
Se ge or
lta
FU
Ba
TE
ST
Ba
tte
ry
POWER
SEC
GATE
1
ER
D
M
Ove otor
rLoa
d
ON
/O
Ba FF
tte
ry Repla
Ba ce
tte
ry
MOTOR
ON-LINE
PRIMARY
GATE
P
T
A
M
N N:
IO
T IO
U T
A N
C TE
T
A
2
R
S
R -4
S 85
-4
85 (+
)
W G (-) R N 24 D
V -
-
-
D
GN12V
R
13
12
5
SeERD
ns
itiv
ity
F
-
M
•
C
1615 14
3
4
1/2
OPEN
COM
CLOSE
GND
er
w
R
n
A
o V
or
L
A
1
cti 2
E
te 1
G
ro R
D
IT
p W
E
M H
t P
LI ITC
to n. .C.) ach rs
en 00
to
W
m -2
Y S
ed io (N e ra
d
R
ir
to
ct
ap C
w n D , ope
TE K
use
n
tr M
fu SE LY l
AT C
be T
ca
B PA
en ith
be
O N ua
T
T
ell
er w
S O L O d
S
C
w
U N C rs en
R
U
o rs
M L Y
to ts. d to
M
p so
TO S
r IL LL nso wh
n
O T
ho u
V
W
GND
LY e
P p se
M PU
nso r MA se 00
12
r In u
N s
M
IN
3 be .
se to R ED -2
O
R
C
d/o e
C
-2
A era O
W
00
an f th ST sors in
P
• op e N OR s M
Sl
ir IT r’
id
ge o U n a r.
00
e
W N to . d Y M se m u
-2
• MO era sed g E AN 2V D T re occ
C
ns. .
1 E
M
io n
op u rsin to R R US ill
ct tio
are ve ed W ITO M lt w
ru
st alla
e ir P
ts u
in st
R w 00 ON pu fa
r
n ’in
be -2 r M in o
tio e d
C e D D
E
alla tic
st o
in la n
ee ir
• J
S o
: V
d
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
3
JO
M
LE AX
LE G
D
FT JO
ON
RI G
GHT
E
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
GATE
STATUS
BATTERY
IN USE
En
PW
Se trapm
ns
or ent
Gui Pr
de otec
lin tio
es n
M
-
M w E
o S R
re
R o to • p NU PE
O onit Pho ell
U M
U
d
re
o g
it in e
n
o ers dg
M ev E
-
MA
ON TRIX
-LI
NE
MOTOR OVERLOAD
”
1
ge
MIN
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
o
D
E
N
2
it SW
Jo
Jo g
g LT
R
T -
Ed
Lim
2
1
3
ge
h Ed
o g
to e
C 2
ell
ll Ed
MOT
ION
P
er
p
m uts
ju p
T in
S
U ed
M us
n
u
Secondary
Gate Operator
M
MotC-2
or 00 UL
Co En
ntro trap
lle
r
otec
tio
n
Ce
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
P
R
A
E
“L
R
e
be
b
be
T . : T can T be
S
3 US
S
n
U rs
ca
M so & M ey U
3 sen 2 rs E th ts M ell
C
ts so R
P
&
2 OR pu Sen FO inpu to
TO 1 .
E
ho 3. S x
ts IT in
P or & ri gins
u N N D B ed
p O R E ts us
or 2 N at
d/ t E M e be
In M EA OR pu un
an pu P on
to L NIT in ny
e in e O e mod
to A
To O d d.
er
d. Edg th th e tim arn
M
1. wire ne re
ei LD m le
d
ng
ar
te
le pe si to O sa d,
H
m
d
E
ca
ju er ire d the ar
OS
di
ev
he
ed N
CL
R w an at is
ct O
. in
2. be ss
te
P min
re ns ep
de L be
P tto
be
.
3. bu til
STO r 5
ch IL
in
fo
m
ea W al
un
s
5 e,
r s
PEN st
fo D n du
in od
O e la
N LE he
ith m
. w
O
w n
od
n ar
m g. be 00 s
n in L C-2 00 . ai d le
.
ar ep IL M -2 ed ag en
D
E
Le be W on MC us n d
R
e tto
O
by Ds or
ar bu an
IT
LE ns OTH s P ors
N
4. se B or
O
r at TO ns s. M
fo er S se op w
op ss n st no
re ar g
P le in e
5. to ep ar
ts
be pu
In
MOT
OR
En
tra
Inpupm
ts:ent Pr
Ph
oto
PO
WER
GND
4-Pin Plug
OPEN
POSITION
RECORDER
12VDC
Wiring operator
turn on/off operator power
Operator should have Input AC power wired to MAX Toroid box, 24V & RS-485 wired between Matrix 1 and MC-200 and
“Optional” External Jog switch wired to MC-200. TURN POWER ON. Certain LEDs should normally turn ON accordingly:
Turn AC Power Switch ON
DO NOT CYCLE GATE
OPERATOR AT THIS TIME
Battery power automatically turns ON.
11
5V
1
MAX Toroid 15 Amp Box
t
pu
t In
lec
Se age or
lt
Vo VAC
5
11 VAC
0
23
A AC IN LED:
Normal - Turns ON.
Error - Not ON. Check AC power.
7 Amp Fuse blown. Replace fuse.
Input AC selector switch MUST be set to CORRECT input AC power.
om
AC
A
S.c
.U
ax
w.M
ww
SE
IN
FU
R
WE
PO
7A
On
r
To
X
MA
mp
p
Am
15
oid
MAX MC-200 Motor Controller
LY
se po
n we
so r
A
rs en
L
A
w tr
R
it ap
M
h m
P
M e
W
C n
-2 t
R
00 pr
12
o
V
P te
W c
M
R tio
U
S
12 n
T
V
be
u
E sed
O
n
A
t
R
op se S ra
p
e n
W ra so en m
M
M ire tor r M so en
A
op ON N W US r t
T
R
ar er IT OR ILL T Gu Pr
IX
b
o
e a O M
R u tor R A NO e w ide te
1
s
E
be ev ed ’s D LL T ire li ct
e
. MC s Y fu d ne io
en C n to s n
M wir rsin
c
20 s LO ti E
po C- ed g
E
0 ors S on D
w 2
w O E . G
U e 00 to A dg
he N D
E
JU NU r M PW N e a
1
n LY (N
or
M SE ON R Y o nd
du , .C
P D IT 1 f /o
al to .)
E in O 2 th r
R
V
P
op ea
E pu R M e 3 ho
er ch
D ts E U In to
ato
or M D S p C
rs
fa U sen T b uts e
ll
ult S
T so e . ca
S
w re rs us
ee
n
ill m . e
d
in
oc a
to
V sta
in
cu
oir
ll
r.
la ati
o
no n
3 2
tic in
1
e str
d’i u
ns cti
ta on
lla s.
tio
n.
R
12 ND - VRS S-48
-48 5 (+
5
GN (-) ) 24 D - V-
PW
R G
-
M
IN OT
P O
U R
T
S
00
M
C
-2
w
er
o
P
R
O
T
O
1.
M
3
w ON
le ire IT
a d O
2. jum rne to R
R p d in ED
e e . p
3. be ve red An uts Se 2
P w rs . y B n
in
un E so 3
bu res ire g
us FO rs
un tto s a d to Ed
ed R M
til ns nd e ge
U
in E th S
be a H ith a
T
pu
ep t th O er nd
ts ey be
L
is e s D inp /or
M ca
he a th ut P
U n
S b
ard me e O 2 ho
T e
Le
o to
be
, le tim PE r 3 C
a
4. by rn O
arn e o N . ell
LE be m P
&
ca
n
E
e
se D p od N
m M S
n
od a TO
fo ns s W ing e
S
e trix P
r o
. las TO
b
5. op BO r o ILL
ts
eg 1
P era T n b
fo P
in
C
to res to H MC e
r
s.
5 LOS
be le s S rs MC -2 ON
m
E
in
In ep arn TO are -2 00 fo
. in
pu in s P u 00 . L r
ts g en b se s E ea
d
ic
are sto so utt d. wh Ds ch
ate
p rs o
en W de
d
no s. a n a
du IL tec
nd g
w
E
al L b te
M
en ain
n
e d
O
tr
d w
O
N
le ith
N
a
IT
arn in
O
In pm
R
m 5m
E
p e
D
od in
u n
.
e, .
t
d
ore to
nit Pho Cell
•
•
:
N:
IO ION
T
UT
CA TTEN
A
2
Mo
D
G
JO HT
G RIG
JOFT
LE
M r
u U ot
n S e
u T c
se ju t
d m io
in p n
p er
u
ts
3
2
1
P
s: t
W
it S
Edg
2
1
e
IX
TR E
MA-LIN
N
Edg O
R
WE
PO
UL p
ra
Ent
ller
0
-20ontro
MCtor C
3
14 1312
D
ER
tor
Mo oad
erL
C
D
EsiRtivity
Sen
D
C
Matrix On-Line LED:
Normal - Turns ON.
Error - Not ON. Check RS-485 wiring to Matrix 1.
Ov
4 5
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
D
Lim
e
ell
15
16
X
MAON
LE
-
2
e
g
d ell
E C
to
o
h
P
B
LT g T Jo g R
Jo
Ed GN
ge D
1
toC
e
•
N
TIO
R MO
TO
MO
Pho
lid
:
S
•
d
ore g
nit rsin ge
Mo eve Ed
R
”
ED
00
M
-2
“L
be
ST s.
MU nsor &
& R se puts
O
ts NIT N in
Inpu MO AR
LE
to
To
•
C
In
O
N
GND
M
2
R
IT
LIM ITCH
SW
Y
ER
TT
BA PACK
RN
EA
B POWER LED:
Normal - Turns ON.
Error - Not ON. Check POWER IN plug on back of MC-200.
PW
Off
Open and Close Limit Sensor Activators
MUST be installed on chain BEFORE cycling
gate or DAMAGE CAN OCCUR!
Limit SW On-Line LED:
Normal - Turns ON.
Error - Not ON. Check LIMIT SWITCH plug.
Mo
Matrix 1
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
H
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
MAG
LOCK
2Sec
E POWER LED:
Normal - Turns ON.
Error - Not ON. Check 24V wiring from MC-200 Primary/Single.
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
F
Tamper NO
COM
GND
Tamper IN
Normal - Turns ON.
Error - Not ON. Check RS-485 wiring to Primary/Single MC-200.
CENTER
PHOTOCELL
UL
SAFETY
3
EDGE 1
MAX
MIN
OFF
G
EDGE 2
ENTRAP
CLOSE TIMER
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
12VDC
GND
MAX
GATE SPEED
OBD PORT
BLACK BOX
24VDC
MIN
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
(+)
GND
(-)
F
H
MOTOR OVERLOAD
LIMIT
SWITCH
ON-LINE
GATE
STATUS
OPEN
COM
CLOSE
I
BATTERY
IN USE
POWER
E
Limit SW On-Line PRIMARY LED (Secondary LED if installed):
Normal - Turns ON.
REVERSE SENSITIVITY
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
G
RADIO GND
CLOSE
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
GND
RADIO SIG.
STOP
OPEN
STOP
CLOSE
COM
GATE DISABLE
POSITION
RECORDER
UL ALARM 12V
ALARM RET
RESET
GND
24V
GND
PARTIAL
OPEN
Motor On-Line PRIMARY LED (Secondary LED if installed):
PRIMARY GATE OPEN RIGHT OPEN LEFT LED:
Normal - Turns ON either LED according to switch setting.
Error - Not ON. Check LIMIT SWITCH plug on back of MC-200.
I
BATTERY IN USE LED:
Normal - Not ON.
Error - Flashes on and off. Battery not plugged in to BATTERY IN port on
BC-7 Battery Module.
MAX BC-7 Battery Module
ry
tte
Ba
4
F
1/2
E
J
lace
Rep ry
tte
/OFF Ba
ON ry
tte
Ba
ST
TE ry
tte
Ba
Mod
ry
tte
Ba ror
Er
IN
ule
K
J BATTERY VOLTAGE LEDs:
Normal - 3 LEDs turn ON - Fully charged batteries.
Batteries need charging - LEDs will turn on in sequence until batteries are
fully charged. Batteries are NOT necessary when AC power is available.
K BATTERY IN ERROR LED:
Normal - Not ON.
Error - Turns ON. Battery not plugged in to BATTERY IN port.
To turn OFF ALL POWER:
1. Turn OFF AC POWER Switch on MAX Toroid 15 Amp. Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the RED ON/OFF BATTERY button until MAX BC-7 LEDs turn ON,
then release button. LEDs will turn OFF.
25
matrix 1
matrix 1 Overview
1 Battery Back-Up Mode - Page 28
2 Primary Gate - Page 28
MATRIX 1
3 Maglock - Page 31
4 Gate Tamper - Page 32
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
5 In-Ground Loop Connection - Page 31
1
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
6 Anti Tailgate - Page 29
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
ANTI
TAILGATE
9 Close Timer - Page 28
EXIT
CENTER
EXIT
5
GATE
TAMPER
SAFETY
6 OFF
ON
10 ID Plug & ID Plug Error LED - Page 32
UL
MIN
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID
PLUG
MAX
GATE SPEED
OBD PORT
BLACK BOX
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
GATE
STATUS
18
19
20
21
22
BATTERY
IN USE
POWER
23
24
25
25 Matrix 1 Power - Page 35
26 Battery in Use - Page 35
MATRIX 1 Back
B Single Pass Anti-Tailgate - Page 29
C Radio Safety Pause - Page 30
OFF
ON
A Gate in Motion Alarms - Page 30
Mode 0
OFF
A
Single Pass Anti-Tailgate
B
ON When turned “ON”; After a vehicle clears the Safety Loop, a closing
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
ON
Mode 1
OFF
Gate in Motion Alarms
Mode 0
ON Motion Alarm sounds before gate moves and continues until gate stops
OFF Motion Alarms OFF
Mode 1
ON Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
OFF Beeper Alert OFF
Radio Safety Pause
OFF
ON
C
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
WWW.Max.US.com
26
11
OPEN
COM
CLOSE
17
23 OPEN/STOP/CLOSE Connection - Page 34
24 Gate Disable - Page 33
Gate Shut-Off
Switch
(Factory Installed)
16
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
15
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
22 Operators Communication LEDs - Page 24 & 35
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
20 Normal Opening Devices - Page 27
21 Close direction Photocell (N.O.) - Page 34
MAX
14
GND
19 Emergency Vehicle/Max Open Inputs - Page 32
REVERSE SENSITIVITY
MIN
24VDC
CLOSE
24V
GND
GND
ID PLUG
ERROR
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
12VDC
STOP
OPEN
POSITION
RECORDER
(+)
GND
(-)
13
12
10
MOTOR MOTION
(+)
GND
(-)
10
16 Motor Motion LEDs - Page 34
matrix 1
EDGE 1
MAX
OFF
13 Partial Open - Page 33
18 Radio Relay - Page 30
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
8
9
12 Radio Power - Page 30
17 Gate Status - Page 34
4
7
CENTER
SAFETY
15 Selectable Gate Speed Control - Page 28
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
8 UL Entrapment LEDs - Page 32
14 OBD Port Black Box - Page 30
MAG
LOCK
2Sec
3
7 Loop Detectors - Page 31
11 UL Alarm Strobe Light Input - Page 33
Gate Shut-Off Switch (Factory Installed) - Page 36
2
MADE IN USA
26
matrix 1
ON
wiring Overview
1
3
4
5
6
7
I
8
480.
DE
FLEC 968.
5
Loop Detectors
See page 31.
In-Ground Loops
S
See page 31.
L afe
MATRIX 1
BATTERY
BACK-UP MODE
oo ty
p
Lo Exit
op
LEAVE
OPEN
MADE in USA
Maglock Connection:
Must be specifically
wired,
See page 31.
ON
= Op TO
64
= Inctim MET 07
= De reasum Se ER
cre e Se ns.
ase ns
D
PO INDI Sens.
ONWER CATO .
OF = No
RS
DEF= No rmal
ONTECT PowePowe
r r
OF = De
F=
2 Hz No tect
LoopFlash Detec
1 Fla Fa =Dela t
2 Fla sh ult y Tim
3 Flashes= Open ing
shes= Sh Lo
orted op
=25%
Both
ch Loop
Cu LED’sof Ind an
PW rrent Fla uctange
R
Lo sh
ce
PrevLED Flaop Faing=
iou sh ult
s Lo ing
op =
Fault
LE
1
2
0
180
MA
3
SW
4
ON 1 SW
5
6
ON ON 2
7
OF OF = Freque
8
OFF ONF = Low ncy
F
SW OF = Mediu
F = Mediu mON 3
Lo
OF = Fa High m-Hi w
F
gh
SW = Fail Se
ON 4 SW il Sacure
ON ON 5 fe
OF OF = Outp
ut
OFF ONF = Pulse B
F
B sa on
SW OF = Pu
En
F = lseme as
try
ON 6
Lo on A
OF = 2
op Ex
Fa it
SWF = NoSeco
ult
ON 7
De nd De
OF = No lay lay
SWF = Infrmal
ini Pres
ON 8
te
Presence
OF = Se
F
en
= Nonsiti
ce
Se vity Bo
nsiti os
vity t
Bo
ost
L S
N
SE
R
TE
ME
TO
EC
FL
DE
NS
SE
WER
T
ETEC
PO
ED
D
I
T
SE
RE
PRIMARY
GATE
LEAVE
CLOSED
S
Lo afety
op
OPTIONS
2
ED
Tel:
OPEN
LEFT
OPEN
1 TIME
Power
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
MAG
LOCK
2Sec
COM
NC
Gate Tamper:
See page 32.
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
MAX 2200
ID Plug ID Plug:
See page 32
MIN
MAX
OFF
POSITION
RECORDER
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
MOTOR OVERLOAD
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
POWER
EN
24V
GND
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
MOTOR
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
LIMIT
SWITCH
ON-LINE
Gate Shut-Off Switch
Factory Installed.
See page 36.
ire o
3-WRadi
Gate Status:
See page 34.
Security Device
Gate Disable
Switch or Timer
See page 33.
ON
See page 30.
F
OF
Emergency/Security Devices
ED
(N.O.)
Stop
S
ES
PR
B
A
T
PA TE
C RY
K
N
O
C
M
M
IN OT
P O
U R
T
S
GND
er
P
M
o
w
e
E
D
”
O
In
T
to pu
O
To M ts
O 2
R
L N &
E IT
A O 3
R R M
N
in se US
p ns T
u o b
ts rs e
2 . “L
&
E
A
3
R
:
N
E
P
Ed
-
-
G
JO HT
G RIG
JOFT
LE
3
p er
u
ts
n
tr
a
In pm
p e
u n
ts t
: P
M r
u U ot
n S e
u T c
se ju t
d m io
in p n
E
Ed
otoC
it SW
Lim
ge
2
1 ATRIXE
M IN
ge ON-L
15
16
X
MA N
DO
LE
3
14 1312
D
ER
tor
Mo oad
rL
Ove
4 5
D
EsiRtivity
Sen
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
ell
Ph
1
2
ST
O
O
PE
N
Pho Edg
to
e
Cel 2
l
:
N:
IO ION
T
UT
CA TTEN
A
Jo
Jo g LT
gR
T
CL
OS
M
lid
d
ore to
nit Pho Cell
Mo
D
N 1
G e
g
d
E
Dry Contact
(N.O.)
S
Telephone Entry
00
In
-2
d
ore g
nit sin ge
Mo ever Ed
R
be
T becan T be
n
MUSthey MUS
ll ca
ors RE uts
Ce
ns
OP 1
oto
Se FO inp
Ph or 3. & STatrix gins.
ED uts BE used
d/or ut 2 EN M e be
un
an
ITOR inp y
e on mod
ge r inpthe OP
ON d to . An
tim
1.M wire rned red. ing Ed eithe LD me learn N
ted
lea pe rs d to HO e sa ard, MOTIO
ica
jum ve re
d th he
R
d
TO
an
wi
ind
MO
2.Rebe ess ns atep is
in.
tectebe ON
m
de
Pr
tto
5
3. bu til be
ch ILL
in.
for
ea W al
un
ts
5 m e,
for Ds du
in od
e las
ON 0. LE when
with rn m
moding. be 20 0s .
ain lea
.
ag d
arn ep ILL C- 20 ed
ED
Le be W on M MC- e us tton d en
by Ds or TH ar
bu s an
ITOR
4.LEsensr BO ators OP nsor . MON
fo er s ST se ps w
op es rn sto no
e
5.Pr to leaepingts ar
be pu
In
R UL
WE Entrap
PO
0 ller
-20ontro
MoCtor C
M
Keypad
Separate power
for Devices.
10K Edge
ER
W
PO
CH
2
GEM - 104
P
k
Lin
R
ate
dG
ore 20
nit
Mo GL-R
M
LE
AR
N
ER
W
PO
TU
STA
S
CH
1
CH
T
U
TP T
U C
O LE
SE
2
M C.
CO .
P/N K
10
M C.
CO .
P/N K
10
CH
1
Refer to
wireless
manual
for more
Normally Open Closing Photocell ONLY.
Wireless
See page 34 (Typically Retro-fit).
information.
NOT UL 325 entrapment protection.
Sensing Edge Radio Receiver
Photocell (N.O.)
ry
da
con r
Se erato 1
Op atrix
M
NO
RS-485
MC-200 Motor Controller
LY
L
S IM
W IT
s e po
IT
C
n we
H
so r
A
rs en
L
C
A
-2
w tr
R
it ap
00
M
h m
P
M e
W
C n
-2 t
R
00 pr
12
o
V
P te
W c
M
D
R tio
U
S
N
12 n
T
G 2V
V
be
1
u
R
E sed
•A
O
n
W
tr
P
R
o se
a
• W pera ns Se pm
o n
M
M ire tor r M so en
A
op ON N W US r t
T
R
a e IT OR IL T G P
IX
• R re u rato OR MA L N be uid rot
1
e
O
w
r
e
s
E
b ev e ’s D LL T ir li c
• M e w ers d. MC se Y C fun ed ne tio
ir in
-2 ns L c to s n
p C e g
00 o O tio E
rs S n D
• U ow -20 d to Ed
w O E . G
e 0
A g
he N D
E
JU NU r M PW N e a
1
n LY (N
or
M SE ON R Y o nd
du , .C
P D IT 1 f /o
to
.)
al
E in O 2 th r
R
V
P
op ea
E pu R M e 3 ho
era ch
D ts E U In to
or M D S p C
to
rs
fa U sen T b uts e
ll
ult S
T so e . ca
S
w re rs us
ee
n
ill m . e
d
in
oc a
to
V sta
cu in
oir
ll
r.
la ati
no on
3 2
tic in
1
e str
d’i u
ns cti
ta on
lla s.
tio
n.
-
P
-
r
e
ow
Normal Opening Devices
Dry Contact (N.O.)
-
MAX OPEN
(Overrides gate
disable switch)
-
(N.O.)
T
3-Button
SE
RE
to
Station
Additional
See page 34.
Reset Button
Normal
See page 34.
Opening
Security Device
Device
R
RS S-485
-485 (+
(- ) R 24GND ) V- -
See page 32.
12 VDC OR 24 VDC
Photocell
Power
OS
CL
Secondary Operator
Connect to MC-200
See pages 24 & 35.
PW
Emergency OPEN
(Overrides gate
disable switch)
Card Reader
TE
GA
OP
24V Power for Matrix 1 ONLY.
See page 35.
ire o
4-WRadi
Key Switch
TE
GA
matrix 1
RADIO SIG.
GND
Normal
Opening
Device
Strobe Light
12VDC 250mA max
See page 33.
REVERSE SENSITIVITY
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
ID Plug Error LED. See page 32
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
GND
12 VDC
OR 24 VDC
Radio Power
EDGE 2
ENTRAP
PARTIAL
OPEN
12VDC
250 mA Max.
EDGE 1
CLOSE TIMER
(+)
GND
(-)
MAX 2200
MAX 1500
ID Plug
MAX 1500
Safety Loops Wired in series
Motion
Sensor
UL LED Indicators ONLY.
See page 30.
PHOTOCELL
UL
SAFETY
Security
Camera
ON = Obstruction
BLINKING = Fault
MON.
PWR
SAFETY
INPUT
GEM-104
UL 325
Type B2
Normally
Closed
10K Sensing
Edge wiring,
See page 19.
External Open/Close
Key Switch
with Dual
Gate
Operators
wiring,
See page 37.
Normally Closed
Photocell wiring,
See page 19.
UL 325
Type B1
27
matrix 1
primary gate - open left / open right
Set the Primary/single gate operator with Primary Gate setting. Secondary operator will
automatically be set to the opposite opening direction as the primary gate operator when
using dual gates.
MATRIX 1
PRIMARY
GATE
G
BATTERY
TERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
ANTI
TE
TAILGATE
MAG
LOCK
COM
NC
EXIT
ON
EXIT
CENTER
CENTE
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
PRIMARY
GATE
OUTSIDE Property
2Sec
AUTOMATIC OPEN/CLOSE
N/CLOSE CONTROLS
CONTR
PHOTOCELL
EDGE 1
UL
MAX
MIN
OFF
EDGE 2
ENTRAP
CLOSE TIMER
C
PARTIAL
OPEN
SECONDARY
OPEN
LEFT
PRIMARY
OPEN
RIGHT
P
PLUG
OPEN
POSITION
RECORDER
12VDC
INSIDE Property
ID PLUG
ERROR
MOTOR MOTION
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
OPEN RIGHT
RADIO GND
OPEN LEFT
RADIO SIG.
GND
Rear Installation NOTE: The Gray Limit sensor MUST be in the gate’s OPEN position
to allow this switch to function as shown. See page 38 for more information.
LED turns ON for
MAX setting ONLY
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
The Close Timer has 16 selectable settings for automatic gate close time.
Knob at OFF position: close timer OFF.
1st click clockwise - Knob at MIN position: 1/2 sec...
MIN
MAX
2nd click clockwise: 1 sec...
OFF
3rd click: 4 sec...
CLOSE TIMER
4th click: 8 sec...
5th click: 12 sec (4 sec increments for each successive click up to 60 sec MAX)
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
P
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
GND
RADIO GND
gate close timer
NOTE: 1/2 sec MIN position is recommended for High Traffic areas.
selectable gate speed control
MATRIX 1
The Gate Speed knob has 16 selectable settings to choose from, with
maximum speed of 12 in/sec and minimum speed of 8 in/sec. Make
sure gate speed is appropriate for the weight and length of the gate.
Limit sensor activators MUST be installed and gate positions learned
BEFORE gate speed can be selected, see page 38.
PRIMARY
GATE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
MOTOR MOTION
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
OPEN
STOP
MAX
CLOSE
PARTIAL
OPEN
REVERSE SENSITIVITY
GND
MOTOR OVERLOAD
OPEN
POSITION
RECORDER
12VDC
GATE SPEED
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
GND
SEC
GATE
POWER
24V
GND
MOTOR
ON
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
TRIKE
STRIKE
ND
GND
YPAD / RDR
KEYPAD
D
GND
PHOTOCELL
TOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
MAX
RADIO GND
NO LIMIT SWITCH /
CLAMP SLIPPING
(+)
GND
(-)
MIN
RADIO SIG.
NOTE: The Auto Gate Sync feature provides synchronous opening and
closing between bi-parting gates (dual gate operators).
BATTERY
BACK-UP MODE
LEAVE
OPEN
MADE in USA
LED turns ON for
MAX setting ONLY
battery back-up mode
The Battery Back-Up Mode setting will determine how the gate operator will function during
an AC power failure. The number of gate cycles on a fully charged battery, using only battery
power depends on the weight and length of the gate.
MATRIX
RIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
DE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
LEAVE OPEN - The gate operator will continue to cycle the gate normally until the
battery power can no longer cycle the gate. When this happens, the gate operator
will open the gate and leave it in the FULL OPEN position until power is restored.
ANTI
TAILGATE
ON
OPEN 1 TIME - The gate operator will automatically FULLY OPEN gate once and
leave it in the OPEN position until power is restored.
28
OFF 1.5Sec
2Sec
MAG
LOCK
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
COM
NC
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
TIME
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
LEAVE
OPEN
OPEN
STOP
MAX
GATE SPEED
MIN
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
FIRE DEPT
GND
MAX OPEN
GND
LEAVE
CLOSED
OBD PORT
BLACK BOX
24VDC
RADIO GND
BATTERY
BACK-UP MODE
GND
RADIO SIG.
LEAVE CLOSED - The gate operator will continue to cycle the gate normally until
the battery power can no longer cycle the gate. When this happens, the gate will
close if not already in the CLOSE position, where it will remain until power is
restored. Enough battery power is retained for a LIMITED time to operate
emergency vehicle entry (Using opening devices connected to FIRE DEPT and/or
MAX OPEN inputs to FULLY open gate).
MAGLOCK
DELAY
OPEN
RIGHT
AUTOMATIC
AUT
MATIC OPEN/CLOSE
OPEN/C
CONTROLS
OPEN
1 TIME
FIRE DEPT/MAX OPEN Inputs
matrix 1
MATRIX 1
anti tailgate
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ON
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
EDGE 1
UL
SAFETY
MAX
MIN
OFF
ENTRAP
EDGE 2
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
MIN
24VDC
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
GND
RADIO GND
is ON
EXIT
EXIT
CENTER
RADIO SIG.
Turned OFF - Close timer will close the gate. If an in-ground safety or exit loop
ANTI
gets activated during the close cycle, gate will REVERSE to the open position.
TAILGATE
Turned ON - (In-ground loops required) Gate will close after all the in-ground
ON
OFF
loops have been cleared no matter how long the close timer is set for. If an
in-ground safety loop gets activated during the close cycle, gate will REVERSE LED stays ON
to the open position.
when Anti Tailgate
ANTI
TAILGATE
MATRIX 1 Back
Single pass anti-tailgate
Turned ON - (In-ground loops required) Gate will close after all the in-ground
loops have been cleared no matter how long the close timer is set for. When an
in-ground safety loop gets activated during the close cycle, gate will PAUSE and
NOT reopen. When loop is cleared, gate will continue to close preventing
UNAUTHORIZED entry.
OFF
OFF
ON
ON
Mode 0
Single Pass Anti-Tailgate
ON When turned “ON”; After a vehicle clears the Safety Loop, a closing
OFF
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
ON
Mode 1
OFF
Gate in Motion Alarms
Mode 0
ON Motion Alarm sounds before gate moves and continues until gate stops
OFF Motion Alarms OFF
Mode 1
ON Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
OFF Beeper Alert OFF
Radio Safety Pause
OFF
ON
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
2
1
WWW.Max.US.com
MADE IN USA
AUTHORIZED
Vehicle
AUTHORIZED
Vehicle
VALID open command was given.
When last Safety Loop is cleared,
gate will close.
NOTE: If a VALID open command
is received at this point, gate will
stop and reopen.
INSIDE Property
SAFETY LOOP
SAFETY LOOP
- Gate Pauses SAFETY LOOP
SAFETY LOOP
OUTSIDE Property
NO VALID open command.
Safety Loop gets activated
and PAUSES the closing
gate.
Gate will NOT reopen.
Vehicle MUST back up for
loop to clear, then gate
continues to close. NO
unauthorized entry.
UNAUTHORIZED
Vehicle
Approaches
NO VALID open command is
given. Vehicle is attempting to
activate safety loop before the
gate’s close cycle is complete,
expecting gate to reopen.
UNAUTHORIZED
Vehicle
29
matrix 1
MATRIX 1
Choose 12 VDC
OR 24 VDC
(250 mA Max.)
Connect a 3-wire or 4-wire radio receiver to Matrix 1.
Choose 12V or 24V, 250 ma max. power.
CLOSE TIMER ON - Each time the remote button is pressed
during the Close Timer countdown (gate is open) causes the
timer to reset and begin again. When close timer countdown
is complete, gate will close.
CLOSE TIMER OFF - Sequence when
pressing remote button:
Press One Time - gate OPENS . . .
NOTE: Signal range is
Press Again - gate STOPS . . .
significantly decreased
when receiver antenna
Press Again - gate CLOSES . . .
remains inside operator
Press Again - gate STOPS . . .
cover.
Sequence repeats when button is
pressed again.
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
Removable
Terminal
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
ANTI
TAILGATE
EXIT
12VDC
ON
EXIT
CENTER
COM
NC
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
GND
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
24VDC
GND
MAG
LOCK
AUTOMATIC OPEN/CLOSE CONTROLS
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
24VD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
GND
ire o
3-WRadi
(+)
GND
(-)
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
radio receiver
Receiver Input
ire o
4-WRadi
MATRIX 1 Back
Radio safety pause
Turned ON - The radio transmitter (remote control) can PAUSE a MOVING
gate by pressing the remote button. Pressing the remote button again will
cause the gate to CONTINUE in the SAME direction. This process can be
repeated as many times as desired.
OFF
ON
OFF
ON
Mode 0
Single Pass Anti-Tailgate
ON When turned “ON”; After a vehicle clears the Safety Loop, a closing
OFF
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
ON
Mode 1
OFF
Gate in Motion Alarms
ON Motion Alarm sounds before gate m
moves and continues until gate stops
Mode 0
OFF Motion Alarms OFF
ON Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
Mode
Mod 1
OFF Beeper Alert OFF
OFF
Radio Safety Pause
ON
ng gate will
ill pause if a radio
di input signal is
When turned "ON" a moving
received. The next radio signal causes the gate to continue in the
original direction.
WWW.Max.US.com
gate in motion alarms
MATRIX 1 Back
ON
Mode 0
OFF
OFF
ON
Mode 0
ON
Single Pass Anti-Tailgate
ON When turned “ON”; After a vehicle clears the Safety Loop, a closing
OFF
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
ON
Mode 1
OFF
Gate in Motion Alarms
Mode 1
ON Motion Alarm sounds before gate moves and continues until gate stops
Mode 0
OFF Motion Alarms OFF
ON Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
Mode 1
OFF
OFF Beeper Alert OFF
OFF
Radio Safety Pause
WWW.Max.US.com
obd port black box
MATRIX 1
30
MADE IN USA
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OBD PORT
BLACK BOX
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
CE
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
PARTIAL
P
OPEN
O
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
GND
OBD PORT
OPEN
STOP
MAX
GATE SPEED
MIN
24VDC
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
OPEN
COM
CLOSE
GATE
STATUS
USB Flash Drive
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
GND
RADIO SIG.
On Board Diagnostics (OBD) port will download a simple .txt file to troubleshoot gate operator errors and to view normal transaction logs.
Plug a USB flash drive into port. LED will flash while file is downloading.
When LED stops flashing, remove flash drive and plug it into any computer
with an available USB port and simple text reader software (ie: notepad,
word for PC or textedit for Mac).
The operator’s event history is stored as a simple .txt file. Contained in
the file is a log of the most recent 1000 events. Quickly identify and
diagnose a complex or intermittent problem. The file can even be
e-mailed to the factory for on site diagnosis if necessary. The files will
be stored as an ongoing event history of the transactions that occur at
the gate operator.
ON
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
BATTERY
IN USE
POWER
24V
GND
MODE 0 - Turned ON - Alarm will sound BEFORE and DURING gate cycle
to alert surrounding area.
NOTE: A strobe light can be connected to UL ALARM connection that will
flash ON and OFF when the alarm is sounding. See page 33.
MODE 1 - Turned ON - Alarm will beep when using ONLY battery power
DURING gate cycling. This brings to attention that only battery power is
being used and NOT normal AC power.
MADE IN USA
NOTE: See page 50 for
more information about
this unique feature.
matrix 1
MAG
LOCK
MATRIX 1
Pos
COM
NC
Tamper NO
COM
EXIT
Maglock
+
-
GND
FAIL
48
DEF 0.96
5 = LECT 8.
6407
Op O
= In tim MET
= Decreaum Se ER
crease Se ns.
se ns.
D
Se
PO IND
ns.
ONWER ICAT
OR
OF = No
S
DEF= No rmal
ONTECT Pow Pow
er er
OF = De
2 HzF= No tect
Lo Flas Dete
op h=
1 Fl Fa Delact
ul
as
y
Tim
2 Fl h t
3 Flashes== Open ing
ashe Sh Lo
s=25 orte op
Both
% chd Loop
Cu LED’ of In an
PW rrent s Flasducta ge
R
Lo hi nc
PrevLED Fl op Fang= e
ious ashi ult
Loop ng=
Faul
t
8
8
1
2
3
SW
4
ON 1 SW
5
6
ON ON 2
7
OF OF = Freque
8
OFF ONF = Low ncy
F
SW OF = Mediu
F Med m-L
ON 3
=
iu
OF = Fa High m-How
F = il
igh
SW Fa Se
ON 4 SW il Sacure
ON ON 5 fe
OF OF = Outp
ut
OFF ONF = Pulse B
F
B sa on
SW OF = Pu
En
F = ls me as
try
ON 6
Lo e on A
OF = 2
op Ex
Faul it
SWF = NoSeco
t
ON 7
De nd De
OF = No lay lay
SWF = In rmal
fin Pr
ON 8
ite es
Presence
OF = Se
F
ence
= Nonsiti
Se vity Bo
nsiti os
vity t
Bo
ost
-LP
00
A18
LM
NS
SE
FL
EC
TO
MET
OPEN
STOP
CLOSE
COM
GATE DISABLE
(+)
GND
(-)
24V
GND
EDGE 1
MAX
EDGE 2
ENTRAP
ID PLUG
ERROR
ID
PLUG
ED
I
7
6
7
COM
NC
Tamper NO
COM
GND
Tamper IN
MOTOR MOTION
4
5
6
7
Tel:
5
Loop Detector
Low Current Draw
(Plug-In)
6
MAG
LOCK
PHOTOCELL
STOP
8
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
R
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
SEC
GATE
BATTERY
IN USE
POWER
24V
GND
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
COM
CLOSE
GATE
STATUS
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
3
4
3
EDI
5
2Sec
GATE
TAMPER
SAFETY
OFF
2
ON
OFF 1.5Sec
UL
MIN
ON
T
POWER
CLOSE TIMER
1
SE
MAGLOCK
DELAY
OPEN
RIGHT
SAFETY
ER
MET
4
I
OPEN
LEFT
OPEN
1 TIME
CENTER
NS
WER
T
EC
I
DET ED
BATTERY
IN USE
AUTOMATIC
UTOMATIC OPEN/CLOSE CONTROLS
FLEC
3
96
SEC
GATE
OPEN
2
480.
FL
MOTOR
ON-LINE
PRIMARY
GATE
MIN
PO
OPEN
COM
CLOSE
GATE
STATUS
PRIMARY
GATE
LEAVE
CLOSED
SE
RE
LIMIT
SWITCH
ON-LINE
MAX
MA
1
ED
5 = EC
8.64
Op TO
= In tim MET 07
= Decreaum Se ER
crease Se ns.
LE
se ns
D
PO INDI Sens.
ONWER CATO .
OF = No
RS
DEF= No rmal
TE
ON CT PowePowe
r r
OF = De
2 HzF= No tect
Lo Flash Dete
op
1 Fl Fa =Delact
2 Flaash ult y Tim
3 Fl shes= Open ing
ashe = Sh Lo
s=25 orted op
Both
% ch Loop
Cu LED’ of In an
PW rrent s Flasducta ge
R
Lo hi nc
PrevLED Fl op Fang= e
ious ashi ult
Loop ng=
Faul
t
BATTERY
BACK-UP MODE
LEAVE
OPEN
MADE in USA
SAFETY
ON
DE
MAX
MATRIX 1
TO
DE
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
(+)
GND
(-)
CENTER
CLOSE
REVERSE SENSITIVITY
MIN
MAX
SPEED
GATE SPEE
EXIT
N
SE
UL ALARM 12V
ALARM RET
RESET
GND
GND
LE
Tel:
MAX
GATE SPEED
OBD PORT
BLACK BOX
24VDC
OPEN/CLOSE CONTROLS
OPTIONS
2
O
OFF N
FA OFF
IL
SA
M OFF FE
ED
OFF
HIG
ON
OFFH
SEN
O
0 SIT FF
IV
3
LO ITY
7 NO W
R
HIG M
H
EC
T
2
LH
EC
ON 10
SEC
OFF
ON
5S
EC O
ON 10 N
SEC
OFF
ON
DET
1
DE
5S
Loop Detector
(Plug-In)
ON
MO
WER
8
STOP
OPEN
POSITION
RECORDER
12VDC
OPTIONS
Reno
Loop Detector
(Plug-In)
PO
7
800
A1
LMS
ID PLUG
ERROR
MOTOR MOTION
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
RE
NA&O
E
EX
T=
SW
0S
SW 8
EC
OFF 2
DLY7
SEC
OFF
SW =
OFF
0S
SW 6
EC ON
BO 5 OFF 2 S
OS O
EC
FF
OFF
SW T
M 4
O
OD
ON N
E
SW FA
O
FR 3
IL N
SEC
EQ
SW =
LO ON URE
SW 2
W
1 ON NO
RM
ON
ON
VEH
OFF
IC
LE
8- DET
30
EC
VD TO
C
R
6
EDGE 2
ENTRAP
FIRE DEPT
GND
N
MAX OPEN
GND
EDI
5
2
EDGE 1
MAX
ON
1
GATE
TAMPER
SAFETY
(+)
GND
(-)
Pos
Plug in desired loop detector
to appropriate loop port
3
SW
4
ON 1 SW
5
6
ON ON 2
7
OF OF = Freque
8
OFF ONF = Low ncy
F
SW OF = Mediu
M
ON 3 F = ediu m-L
OF = Fa High m-How
F
igh
SW = Fail Se
ON 4 SW il Sacure
ON ON 5 fe
OF OF = Outp
ut
F
Pu
F
OF ON = lse B
F
B sa on
SW OF = Pu
m En
ON 6 F = lse e as try
Lo on A
OF = 2
op Ex
Fa it
SWF = NoSeco
ult
ON 7
De nd De
OF = No lay lay
SWF = In rmal
fin Pr
ON 8
ite es
Presence
OF = Se
F = ns
ence
iti
No vi
Se ty Bo
nsiti os
vity t
Bo
ost
COM
NC
Tamper NO
COM
GND
Tamper IN
UL
ADIO GND
RADIO
0.96
CENTER
ID
PLUG
RADIO SIG.
FL
8.64
5 = EC
Op TO
= In tim MET 07
= Decreaum Se ER
crease Se ns.
se ns
D
PO INDI Sens.
ONWER CATO .
OF = No
RS
DEF= No rmal
ONTECT PowePowe
r r
OF = De
2 HzF= No tect
LoopFlash Dete
1 Fl Fa =Delact
2 Flaash ult y Tim
3 Fl shes= Open ing
ashe = Sh Lo
s=25 orted op
Both
% ch Loop
Cu LED’ of In an
PW rrent s Flasducta ge
R
Lo hin nc
PrevLED Fl op Fa g= e
ious ashi ult
Loop ng=
Faul
t
LE
EXIT
PARTIAL
OPEN
Maglock
Power
OPTIONS
ED
I
DE
MAG
LOCK
PHOTOCELL
PHOT
1
Tel:
48
2Sec
OFF
SAFETY
Loop Detectors
Matrix 1 will accept third party loop detectors in the 2 ports (center loop is NOT used). Each
loop detector has a corresponding in-ground loop that must be connected for the loop
system to operate (see below). Power down Matrix 1 BEFORE plugging in loop detectors.
Refer to the chosen loop detector instruction manual for more information.
Plug-In Loop Detectors
ON
OFF
Neg
4
OFF 1.5Sec
CENTER
MIN
Tamper IN
3
MAGLOCK
DELAY
OPEN
RIGHT
AUTOMATIC OPEN/CLOSE CONTROLS
CLOSE TIMER
GND
2
PRIMARY
GATE
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
ANTI
TAILGATE
Neg
ON
BATTERY
BACK-UP MODE
LEAVE
CLOSED
+
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
2Sec
FIRE DEPT
GND
MAX OPEN
GND
Maglock MUST be connected as shown.
MAGLOCK DELAY: You MUST select a time
delay when using a maglock.
Maglock power disengages 1.5 sec or
2 sec before gate starts opening.
MAGLOCK LED (Monitors Maglock):
ON - Locked OFF - Unlocked
Flashing - Problem with Maglock
RADIO GND
OFF 1.5Sec
RADIO SIG.
MAGLOCK
DELAY
maglock
ON
1
2
0
3
SW
4
ON 1 SW
5
6
ON ON 2
7
OF OF = Freque
8
OFF ONF = Low ncy
F
SW OF = Mediu
F Med m-L
ON 3
=
iu
OF = Fa High m-How
F
igh
SW = Fail Se
ON 4 SW il Sacure
ON ON 5 fe
OF OF = Outp
ut
OFF ONF = Pulse B
F
B
on
SW OF = Pusam En
F = ls e as try
ON 6
Lo e on A
OF = 2
op Ex
Faul it
SWF = NoSeco
t
ON 7
De nd De
OF = No lay lay
SWF = In rmal
fin Pr
ON 8
ite es
Presence
OF = Se
F
ence
= Nonsiti
Se vity Bo
nsiti os
vity t
Bo
ost
80
A1
LMS
SE
N
ER
MET
TO
FLEC
DE
SE
Plug-In Loop Detector
NS
R
WE
PO
T
TEC
DE
I
ED
T
SE
RE
ER
DE
S
EN
S
PO
WER
T
EC
DET
I
ED
Com, Gnd (Black)
T
SE
RE
r
we
Po inal
m
r
e
T
External Loop Detectors
Third party external loop detectors can be used if
desired with the MAX External Loop Detector Cable
Adapter. (1) One is included with the operator but
more can be purchased if needed.
Wire to
l
na back of
r
e
Extoop r detector
L cto
te
De
Loop Detect
Output (White)
Power 15 VDC (Red)
MAX External Loop
Detector Cable Adapter Power Terminal
In-ground loop connection
Connect each in-ground loop wires to the appropriate input. Lead wires
should be twisted together 6 twists per foot minimum.
See page 16 for in-ground loop installation.
Safety loop wires must be wired in series.
Each LED will light when the corresponding
loop detector get activated by a vehicle
passing over its in-ground loop.
LEDs will flash when there is an error with
the corresponding loop detector.
Removable Terminal
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
EXIT
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TTAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
CENTER
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
SAFETY
Safety loops need
to be wired in series.
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
RADIO SIG.
GND
Lead Wires
Outside Property
SAFETY LOOP
SAFETY LOOP
EXIT LOOP
Inside Property
31
matrix 1
MAX 1500
id plug
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
AU
ANTI
TAILGATE
MAX 1500
Yellow
AN ID Plug comes standard on Matrix 1. It identifies
the model of gate operator and MUST be plugged in
or the Matrix 1 WILL NOT function.
Yellow plug MUST be used for the MAX 1500.
Red plug MUST be used for the MAX 2200.
EXIT
EX
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
PHOTOCELL
EDGE 1
SAFETY
MIN
OFF
EDGE 2
ENTRAP
CLOSE TIMER
ID PLUG
ER
ERROR
PARTIAL
OPEN
Power
Warning
Light
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
GND
Security
Camera
Power
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
Tamper NO
Tamp
COM
GND
Tamper IN
GATE
GA
TAMPER
EXIT
OFF
CENTER
PHOTOCELL
PHOTOC
EDGE 1
SAFETY
MIN
MAX
OFF
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
Motion
Sensor
OPEN
STOP
CLOSE
COM
GATE DISABLE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
NOTE: See page 47 for
more information about
this unique feature.
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
PHOTOCELL
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/
OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
UL
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
UL entrapment LEDs
UL ENTRAPMENT LEDs will indicate when a OPENING DIRECTION
Photocell and/or Sensing Edge(s) have been activated. If alarm gets
triggered, press reset button on side of operator to turn alarm off.
NOTE: UL safety approved devices are wired to the MC-200 motor
controllers ONLY. DO NOT wire them to the Matrix 1.
EDGE 2
ENTRAP
CLOSE TIMER
FIRE DEPT
GND
MAX OPEN
GND
GATE
TAMPER
Tamper NO
COM
GND
Tamper IN
RADIO GND
The GATE TAMPER can be used for various
functions such as turning a warning light, siren or
camera on when the gate is tampered with
(Vandalized Gate). The gate operator defines a
“Vandalized Gate” as UNAUTHORIZED movement
of the gate. This can occur if the chain is dropped
and gate is manually moved from the closed
position or the gate is forced open from the closed position
without authorization.
TAMPER NO/Com Relay: Connect a warning light, siren, camera
or an existing alarm system to relay.
TAMPER IN/GND Input: Connect a sensor device to input. When
Tamper In/GND gets triggered, device that is wired to Tamper
relay (NO/Com) will activate.
Siren
MAX 2200
Red
GND
STOP
OPEN
POSITION
RECORDER
12VDC
12
RADIO SIG.
Existing
Building
Alarm
System
ID
PLUG
RADIO SIG.
MAX 2200
ID
PLUG
ID PLUG ERROR LED: Will light when ID PLUG is
missing.
Gate Tamper
MATRIX 1
ID PLUG
ERROR
ON
EDGE 1
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
Tam
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
ENTRAP
EDGE 1
UL
SAFETY
EDGE 2
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
STOP
OPEN
POSITION
MAX
SPEED
GATE SP
ED
12VDC
ND
GND
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SEN
SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWIT
SWITCH /
CLAMP
CLAM SLIPPING
24VDC
OPEN
COM
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
T
FIRE DEPT
GND
MAX OPEN
GND
REVERSE SENSITIVITY
RADIO GND
REVERSE SENSITIVITY LED: Will light when the gate encounters an
obstruction triggering the ERD sensor.
O SIG.
RADIO
GND
emergency vehicle/max open inputs
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
FIRE DEPT
GND
MAX OPEN
GND
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
32
Tamper NO
COM
GND
Tamper IN
CENTER
PARTIAL
OPEN
12VDC
GND
POSITION
RECORDER
OBD PORT
BLACK BOX
24VDC
DC
OPEN
STOP
MAX
GATE SPEED
MIN
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
Knox
Box
Key
Switch
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
FIRE DEPT
GND
MAX OPEN
GND
MAX OPEN Input: Can be connected to a key switch and used as an
ADDITIONAL input from the FIRE DEPT input. The input will override
the GATE DISABLE input and allow SECURITY personnel FULL 24/7
access. Gate FULLY opens.
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
IN USE
POWER
24V
GND
FIRE DEPT lnput: Should be connected to a knox box device to allow
the proper authorities to gain emergency access when necessary. The
input will override the GATE DISABLE input and allow EMERGENCY
personnel FULL 24/7 access. Gate FULLY opens.
matrix 1
gate disable
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
MAG
LOCK
2Sec
COM
NC
An ON/OFF switch or 7-Day timer devices can be connected to the GATE DISABLE
input. When these devices are turned ON, they will DISABLE normal opening
devices such as keypad, exit loop etc. The FIRE DEPT/ MAX OPEN and RADIO
inputs will remain enabled when GATE DISABLE has been turned ON. This is
useful when the gated area needs to be secured from ALL but emergency or
authorized vehicle entry. Some examples are: Residential home vacation period or
during closed hours of a business when no one can monitor the property.
When GATE DISABLE is turned ON: The operator will beep for 3 minutes
BEFORE arming itself. This allows time to turn ON GATE DISABLE and
Enabled inputs when
GATE DISABLE is turned ON.
leave the property before it is armed.
NOTE: See page 50 for
When FIRE DEPT/MAX OPEN gets activated: Gate opens and GATE
more information about
TAMPER relay will activate immediately.
ON/OFF
7-Day Timer
this unique feature.
Switch
When RADIO Input gets activated: Gate opens and GATE TAMPER relay
will activate after 3 min. This allows time to turn OFF GATE DISABLE or disarm an existing building alarm system if connected.
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
GND
GATE DISABLE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
OP
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
OP
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
CLOSE
REVERSE
SENSITIVITY
RE
MOTOR OVERLOAD
OV
MIN
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
NO
O LIMIT SWITCH /
CLAMP
MP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
(+)
GND
(-)
SEC
GATE
POWER
24V
GND
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
(+
TRIKE
STRIKE
ND
GND
KEYPA
KEYPAD / RDR
GND
PHOTOCELL
PHO
GND
GN
FIRE DEPT
GND
X OPEN
MAX
D
GND
RADIO GND
G.
RADIO SIG.
GND
ON
F
OF
IMPORTANT: It is NOT recommended activating the GATE DISABLE device while persons are present inside the property.
partial open
A gate can set to partially open by recording the PARTIAL OPEN gate cycle. LED will stay lit when PARTIAL OPEN is ON. The
gate MUST open a minimum of 6 ft for a single vehicular gate and 10 ft for dual vehicular gates. If the opening distance you
record is less than the minimum allowed, the operator will beep, NO recording will register and the LED will turn OFF. Retry
recording with a greater opening distance. LED remains ON when recording is successful.
IMPORTANT: Limit sensor activators MUST be learned BEFORE Partial Open can be recorded.
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
MOTOR MOTION
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
TAILG
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
EXIT
CLOSE
To ERASE PARTIAL OPEN recording:
Press and HOLD PARTIAL OPEN button for 5 sec. Blue LED turns OFF.
PHOTOCELL
EDGE 1
UL
EDGE 2
ENTRAP
PARTIAL
OPEN
GND
ID PLUG
ERROR
MOTOR MOTION
OPEN
O
POSITION
RECORDER
12VDC
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSIT
SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
RADIO GND
To RECORD PARTIAL OPEN:
1. With gate in CLOSED position, press and release PARTIAL
OPEN
STOP
OPEN button to START recording. Blue LED starts flashing.
POSITION
RECORDER
2. Press Motor Motion OPEN button to start gate’s open cycle.
3. Press Motor Motion STOP button when gate gets to desired partial open position.
4. Press PARTIAL OPEN button AGAIN to STOP recording. LED stops flashing,
open position has been successfully recorded. LED remains ON.
RADIO SIG.
PARTIAL
OPEN
NOTE: See page 49 for
more information about
this unique feature.
NOTE: The FIRE DEPT and/or MAX OPEN connected devices will always FULLY open gates even when the partial open is being used.
UL alarm warning light input
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
Alarm
Reset
Button
UL ALARM 12V
ALARM RET
RESET
GND
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
PHOTOCELL
UL
SAFETY
EDGE 1
MAX
MIN
OFF
ENTRAP
EDGE 2
CLOSE TIMER
PAR
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
LUG
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
G
CLOSE
REVERSE SENSITIVITY
TIVITY
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
Strobe
Light
RADIO GND
GND
RADIO SIG.
Press ALARM RESET BUTTON to turn
OFF activated strobe light.
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
IN USE
POWER
24V
GND
A UL ALARM (strobe light) can be
connected. It will turn ON when the
GATE IN MOTION - Mode 0 and/or
Mode 1 are turned ON (see page 30).
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
STROBE LIGHT: 12VDC - 250 mA max.
33
matrix 1
MATRIX 1
gate status monitoring
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
OPEN
COM
CLOSE
GATE
STATUS
GATE STATUS LEDs will turn ON when gate is in the OPEN or
CLOSED position.
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MAX
MIN
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
Connect a gate monitoring device to GATE STATUS relays to
Remote Gate
show if gate is in the OPEN or CLOSED position.
Monitoring Device
in Remote Location
OPEN/COM Relay: Activates when gate gets to the OPEN position.
CLOSE/COM Relay: Activates when gate gets to the CLOSED position.
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
GND
CLOSE
REVERSE SENSITIVITY
Y
MOTOR OVERLOAD
OVERL
MIN
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
CL
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
ED
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
RADIO GND
OS
CL
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
24VDC
RADIO SIG.
TE
GA
OPEN
POSITION
RECORDER
12VDC
N
PE
O
TE
GA
UL ALARM 12V
ALAR RET
ALARM
RESET
GND
open / stop / close Connection
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
OPEN
STOP
CLOSE
COM
GATE DISABLE
The OPEN/STOP/CLOSE inputs will allow a standard 4-wire
3-Button Station or an additional External RESET Button to be
connected.
Corresponding LEDs will light when each button is activated.
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
CLO
PAR
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
D
ID
PLUG
OPEN
POSITION
SITION
RECORDER
R
12VDC
OPEN
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
CLOSE
REVERSE
SENSITIVITY
REVE
MOTOR OVERLOAD
OVE
MIN
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
to
Com
(+)
GND
(-)
SEC
GATE
POWER
24V
GND
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(-)
STRIKE
GND
KEYPA
KEYPAD / RDR
GND
PHOTOCELL
PH
GND
G
ET
RE DEPT
FIRE
GND
MAX OPEN
GND
STOP
Com
O SIG.
RADIO
3-Button
Station
S
ES
PR
DIO GND
RADIO
GND
STOP
CLOSE
S
RE
Additional External
Reset Button
closing photocell connection
MATRIX 1
EXIT
12VDC
OFF 1.5Sec
2Sec
MAG
LOCK
ON
EXIT
CENTER
COM
NC
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
GND
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
24VDC
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
24VD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
RADIO SIG.
GND
PHOTOCELL
GND
12V or 24V
Photocells
MAGLOCK
DELAY
OPEN
RIGHT
AUTOMATIC OPEN/CLOSE CONTROLS
12VDC
Power
GND
N.O.
GND
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
ANTI
TAILGATE
GND
OUTSIDE Property
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
Choose 12 VDC OR 24 VDC
(250 mA Max.)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
The Normally OPEN PHOTOCELL input will allow a CLOSING DIRECTION
Normally OPEN PHOTOCELL to be connected. 12V or 24V power can be
supplied for the photocells.
IMPORTANT: This input is NOT UL 325 entrapment protection.
Additional CLOSING Cycle
Photocells can be connected.
INSIDE Property
NOTE: This input is typically used when an existing normally open
photocell needs to be retro-fitted to this operator when this
operator is replacing an obsolete operator.
MATRIX 1
LEAVE
CLOSED
ANTI
TAILGATE
EXIT
ON
OFF 1.5Sec
EXIT
CENTER
MAG
LOCK
OFF
COM
NC
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
UL
MIN
M
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
GND
OBD PORT
BLACK BOX
OPEN
EN
STOP
MAX
GATE SPEED
MIN
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
RADIO GND
RADIO SIG.
GND
FIRE DEPT
GND
MAX OPEN
GND
NO LIMIT SWITCH /
CLAMP SLIPPING
2Sec
GATE
TAMPER
SAFETY
SAFETY
MOTOR OVERLOAD
12VDC
34
MAGLOCK
DELAY
OPEN
RIGHT
CENTER
REVERSE SENSITIVITY
NO LIMIT SWITCH/CLAMP SLIPPING LED: Will light when either limit sensor
does NOT activate from it’s learned positions.
OPEN
LEFT
OPEN
1 TIME
AUTOMATIC OPEN/CLOSE CONTROLS
REVERSE SENSITIVITY LED: Will light when the gate encounters an obstruction triggering
the ERD sensor.
MOTOR OVERLOAD LED: Will light when excessive current is being drawn
by motor caused by damaged gate hardware or gate is too heavy.
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
OPEN
MADE in USA
BATTERY
IN USE
POWER
24V
GND
motor motion leds
matrix 1
gate operators communication leds
PRIMARY/SINGLE operator’s MC-200 has been wired to
the PRIMARY GATE (Factory Wired).
MATRIX 1
SECONDARY operator’s MC-200 gets connected to the
SEC GATE (+, GND, -). See page 24.
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LIMIT
SWITCH
ON-LINE
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
ANTI
TAILGATE
EXIT
MOTOR
ON-LINE
ON
EXIT
CENTER
OFF
PHOTOCELL
(+)
GND
(-)
(+)
GND
(-)
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
PLUG
OPEN
POSITION
RECORDER
GND
STOP
MAX
GATE SPEED
OBD PORT
K BOX
BLACK
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR
OVERLOAD
M
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
SL
MAX
OPEN
COM
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
PHOTOCELL
P
KEY
KEYPAD / RDR
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
MAX OPE
OPEN
FIRE DEPT
RADIO GND
RADIO SIG.
GND
GND -
Secondary
MAX MC-200
MATRIX
BOARD
24V power for matrix 1
RS-485 (+) RS-485 (-) GND PWR 24V -
BATTERY LIMIT ALARM
PACK SWITCH
not used -
MOTOR
INPUTS
not used -
Power In
PWR 12V -
MATRIX
BOARD
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
POWER
24VDC POWER from PRIMARY/SINGLE operator ONLY.
POWER LED: Will light when 24V low voltage power is
connected.
ANTI
TAILGATE
24V
GND
EXIT
ON
EXIT
CENTER
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MAX
MIN
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
Factory Wired
OPEN
POSITION
RECORDER
12VDC
GND
MAX
X
GATE
OBD PORT
BLAC BOX
BLACK
STOP
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
C
REVERSE SENSITIVITY
SPEED
EED
MOTOR OVERLOAD
MIN
24VDC
NO
O LIMIT SWITCH /
MAX
OPEN
COM
CLOSE
GATE
GAT
STATUS
ND
GND
battery in use led
GATE DISABLE
POWER
24V
GND
GND
(+)
GND
STRIKE
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
BATTERY
IN USE
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
C
PHOTOCELL
UL
SAFETY
EDGE 1
MAX
MIN
OFF
ENTRAP
EDGE 2
CLOSE TIMER
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
CLOSE
REVERSE SENSITIVITY
MOTOR
TOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
C
CLOSE
GATE
STATUS
MOTOR
OTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
BATTERY
IN USE
POWER
24V
GND
LIM
LIMIT
SWITCH
ON-LINE
OPEN
STOP
CLOSE
COM
GATE DISAB
DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
GND
RADIO GND
POWER
PARTIAL
OPEN
RADIO SIG.
BATTERY IN USE LED will light when operator is using ONLY battery
back-up power. The GATE IN MOTION Alarm can be set up to sound alarm
when operator is using ONLY battery power DURING gate cycling. This
brings to attention that only battery power is being used and NOT normal
AC power. See page 30.
LED Flashing NOTE: BATTERY IN USE and POWER LEDs flash together
when the battery is not plugged into the BATTERY IN port of the MAX BC-7
Battery Module. Make sure battery plug is correctly installed and there is no
damaged or loose wires.
BATTERY
BATTER
IN USE
MATRIX
BOARD
(+)
GND
(-)
Primary/Single
MAX MC-200
RADIO SIG.
BATTERY LIMIT ALARM
PACK SWITCH
GND -
MOTOR
INPUTS
RS-485 (+) RS-485 (-) GND PWR 24V -
Power In
not used -
MOTOR
PWR 12V -
LIMIT
SWITCH
not used -
NOTE: DO NOT power external devices using this
connection. This power is reserved for Matrix 1 and
UL opening cycle entrapment photocells ONLY.
MAGLOCK
DELAY
OPEN
RIGHT
AUTOMATIC OPEN/CLOSE CONTROLS
(+)
GND
(-)
GND -
Primary/Single
MAX MC-200
MOTOR
RS-485 (+) RS-485 (-) GND PWR 24V -
BATTERY LIMIT ALARM
SWITCH
PACK
not used -
RS-485
PWR 12V -
MOTOR
INPUTS
SEC
GATE
EDGE 1
UL
MAX
MIN
PRIMARY
GATE
Factory Wired
not used -
Power In
COM
NC
Tamper NO
COM
GND
Tamper IN
CENTER
12VDC
MOTOR ON-LINE LEDs: will light for each
gate operator’s MC-200 Motor Controller that
the Matrix 1 is successfully communicating
with.
MOTOR
MAG
LOCK
GATE
TAMPER
SAFETY
SAFETY
LIMIT SWITCH ON-LINE LEDs: will light for each gate
operator’s limit switch that the Matrix 1 is successfully
communicating with.
2Sec
AUTOMATIC OPEN/CLOSE CONTROLS
35
matrix 1
gate shut-off switch
This factory installed switch will disable the normal opening
devices when turned ON, such as keypad, exit loop etc. Only
the Jog Left or Jog Right buttons on the MAX MC-200 motor
controller will operate gate when Gate Shut-Off switch is ON.
PhotoCell Edge Limit SW
Edge MATRIX
UL
ON-LINE
Entrap
Motor Controller
15 14 13
16
12
ERD
LED ON
3
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
MC-200
MAX
2
1
POWER
4
JOG JOG
LEFT RIGHT
5
ERD
Motor
OverLoad
Sensitivity
MAX MC-200 motor controller
This feature is useful when the gate operator is being serviced.
The gate operator can not accidentally get activated while this
switch is ON.
IMPORTANT: When the Gate Shut-Off switch is turned ON,
operator will be disabled and it will “BEEP” for a few
seconds to indicate that Gate Shut-Off switch is ON.
ch
wit ton
S
ff ut
t-O
te
Ga
u
Sh
set
Re
rm
Ala
B
Dropping the Chain
If an existing alarm system (Building alarm system) is connected to the GATE TAMPER relay, notify proper authorities BEFORE
dropping the chain.
MATRIX 1
36
PRIMARY
GATE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
PHOTOCELL
UL
SAFETY
EDGE 1
MAX
MIN
OFF
S
ENTRAP
EDGE 2
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
BATTERY
IN USE
POWER
24V
GND
PRIMARY
GATE
(+)
GND
(-)
MOTOR
ON-LINE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
RADIO GND
GND
RADIO SIG.
IMPROPER Dropping of Chain (Vandalize):
Gate Shut-Off switch is NOT turned ON.
When the chain is improperly dropped (Vandalized), the
OPERATOR ALARM and GATE TAMPER relay will activate.
The operator will shut down all operating functions.
The alarm reset button MUST be pressed to turn OFF the
alarm and reset the operator. If GATE TAMPER relay is
connected to an existing building alarm system, then they
will get a triggering of their alarm system and should be
notified of the situation.
BATTERY
BACK-UP MODE
LEAVE
OPEN
MADE in USA
FIRE DEPT
GND
MAX OPEN
GND
PROPER Dropping of Chain (Normal Operator Servicing):
1. Turn Gate Shut-Off switch ON to disable operator alarm.
2. Drop the Chain.
ONF
3. GATE TAMPER relay WILL be activated.
OF Gate ff
O
4. Service operator.
utSh
5. Reconnect the chain to gate.
5. Turn Gate Shut-Off switch OFF.
ON
6. Rearm an alarm system that may be connected
F te
OF hGuat-Off
to the GATE TAMPER relay.
Gate
Tamper
Relay
matrix 1
external Open/Close key switch - optional
An Optional External Open/Close Key Switch can be connected that allows dual gate operators to be electronically moved
open or closed at the same time by wiring both operators to the external key switch.
Connect (3) three wires from each MAX MC-200 Motor Controllers to an External Open/Close Key Switch depending on your
specific installation, see below.
Key Switch
Key Switch
Secondary
MAX MC-200
Motor Controller
Close
Terminal
Primary/Single
MAX MC-200
Motor Controller
SECONDARY
OUTSIDE Property
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
PRIMARY
Close
Terminal
Open
Terminal
Gnd
Open
Terminal
Secondary
MAX MC-200
Motor Controller
Gnd
Primary/Single
MAX MC-200
Motor Controller
SECONDARY
OUTSIDE Property
INSIDE Property
PRIMARY
INSIDE Property
OPEN LEFT
OPEN RIGHT
OPEN RIGHT
OPEN LEFT
Primary/Single Open LEFT
Primary/Single Open RIGHT
External Open/Close
Key Switch
IMPORTANT:
The External Open/Close Key Switch
WILL override GATE DISABLE
switch/timer device when turned
ON but the GATE TAMPER relay
WILL be activated.
E
OS
CL
EN
OP
Se
M MA co
ot X nd
or M a
Co C- ry
nt 20
ro 0
lle
r
1
-
d
s
e
u
t
s
o
P
2
n
W
R
N
O
00
C
-2
”
M
M
u U
n S
u T
se ju
d m
in p
p er
u
ts
3
t
LY
se po
n we
so r
r s en
w tr
it ap
h m
M e
C n
-2 t
00 pr
12
o
M
V
P te
W c
M
R on
R tio
U
ev it
S
12 n
er or
T
V
be
si ed
E n
us
d g
g
e
•
e
d
A
op s e
M
• W er ns
o
n
ato or
it
ir
M
M
e
r
P ore
op ON N W US
h d
o
a e IT OR IL T
C to • re rato O M L N be
R u r R A
el
O w
s
E
l
b ev e ’s D LL T ir
• M e w ers d. MC se Y C fun ed
ir in
-2 ns L c to
p C e g
00 o O tio E
r S n D
• U ow -20 d to Ed
w sO E . G
e 0
A g
he N D
E
JU NU r M PW N e a
1
n LY (N
Y
O
n
S
or
M E N R
du , .C
d
P D IT 1 of /o
al to .)
E in O 2 th r
C
R
V
P
op ea
A
E pu R M e 3 h o
er c h
A U
D ts E U In to
T T
ato
or M D S p C
T IO
E N
rs
fa U sen T b uts e
N :
ll
S
u
e
s
.
T S
lt T o u
ca
IO e
w re rs s
n
ill m . e
N e in
d
oc a
:
to
V sta
cu in
oir
ll
r.
la ati
n o on
3 2
tic in
1
e str
d’i u
ns cti
ta on
lla s.
tio
n.
o
P
n
-
ST
O
P
-
PE
N
-
)5 (+ (-) - -48 85
D
RS S-4 GN 4V R
R2
PW
1
O
-
IX
In
to pu
To M ts
O 2
L N &
E IT
A O 3
R R M
N
in se US
p ns T
u o b
ts r e
2 s. “L
&
E
A
3
R
:
N
E
D
RM
R
T
A
M
it S
W
•
Lim
MA
ON TRIX
-LIN
E
n
or
io V
1
ct 2
E
te 1
G
ro R
D
p W
E
t P
.) ch rs
to .
en 00
d on N.C ea ato
m -2
ire cti ( to r
ed
ap C
w n D , op e
us
n
tr M
fu SE LY l
be T
ca
en ith
be
O N ua
T
T
ell
er w
S NO CL s O d
S
C
n
w s
U
r
U
o r
M ILL LY so he
to ts. to
M
p so
n
or W L en w
ho u e d
V
p
GND
s
LY e
P
ns r MA s 00
12
r In u
N s
M
se ato R ED -2
/o 3 be .
O
R
C
d
C
-2
e
s
A er O
W
00
an th ST or
P
• op e N OR ’s M
S
e of U ns ain
lid
ir IT r
g
00
r.
e
W N to . d Y M se m u
-2
.
• MO era sed g E AN 2V D T re occ
C
ns .
E
1
M
tio on
op e u rsin to R R US ill
uc ati
ar e ed W O M lt w
str ll
ev ir P IT ts u
in sta
R w 00 ON pu fa
r
n ’in
be -2 r M in o
tio d
C
D
lla tice
sta o
in la n
ee ir
S o
d
re
o g
it in
n s e
o er dg
M ev E
R
Secondary
2
Edg 1
e
AL
A
: V
N N:
IO
T IO
U T
A N
C TE
T
A
to
Mo
n
BAT
PA TER
CK Y
SW LIMIT
ITC
H
En
Se trap
ns me
or nt
Gu Pro
ide te
lin ctio
es n
OR
e D
d
M w E E
o S R
re
o to • p U PE
it o l
N
n h l
U M
o P Ce
• JU
M
UL p
ra
Ent
ell
Edg
e
le
ng
Si 00 r
y/ -2 lle
ar C tro
im M n
Pr AX Co
M or
ot
R
0 ller
-20ontro
MC r C
toC
R
Mo -2
tor 00 UL
Co Ent
ntr rap
olle
r
O
4 5
D
EsiRtivity
M
e N
Edg O
WE
PO
W
IX
TR E
MA-LIN
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
it S
Lim
PO
WE
MC
Pho
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
to
1
D
ER
tor
M o oad
rL
ve
14 1312
Pro
tec
tio
n
Jo
Jo g
L
E G gR T
d N T g
P E e D h d 1
o g
to e
C 2
1
ell
2
-
o
LT g T R
e
Edg
ell
2
toC
Pho
:
3
er
p s
m ut
ju p
T in
S
U ed
M us
n
u
Jo
h
P
g D
N 1
G e 2
g
d ge ll
E Ed Ce
Jo
tra p
En In
3
Se
”
e
lid
X
MA N
DO
LE
G
JO HT
G RIG
JOFT
LE
D
S
15
16
E
P
O
ST
00
OR
be n be be
ST ca ST
n
MU they MU
l ca
rs
Cel
P
so RE ts
to
en FO inpu
.
TO 1
Pho or 3. & S atrix gins
D S BE ed
RE puts unus
d/or t 2 PEN M e be
ITO in ny
e an inpu O e on od
ON d to d. A
dg er the tim n m
1.M wire arne red. ng E eith LD me lear N
ted
le mpe ersi d to HO e sa ard, MOTIO
E
ca
ju ev ire
d th he
R
OS
TO
ed N
an at is
w
CL
indi
MO
2.R be
in.
tect be O
ress ns ep
de
5m
3.P butto til be
r
ch ILL
in.
fo
ea W al
un
5 m e,
sts
for Ds n du
in od
e la
ON . LE whe
with n m
moding. be -200 s .
ain lear
ag d
arn ep ILL C -200 ed
D.
n
Le be s W on M MC e us tton d en
RE
tio
by D or TH ar
bu
ITO
s an
tec
4.LEsensr BO ators TOP nsor s. MON
S se
ro
fo er
op ress arn g stop now
tP
e
5.P to le epin ts ar
en :
be pu
pm uts
In
M
INP OTO
UT R
S
u
1
R
IX
-
P
M
A
T
R
RS S-48
-48 5 (+
5
GN (-) ) 24 D - V-
D
N
G 2V
1
R
PW
W
R
N
R
A
E
“L
e
b
T . :
S s 3
U or
M s &
3 sen 2
ts
&
2 OR p u
ts IT in
u N N
p O R
In M EA
to L
N
PE
-2
C
In
Po
we
r In
O
n
tio
tec es
ro lin
tP e
en uid
pm r G
tra nso
En Se
GND
R
TO
MO
1.M
w O
le ired NIT
2.R jum arne to inORE
pe d.
D
3.P be weversi red. Any puts Sen
un BE sors
ire ng
bu re
us FO
un tto ss an d to Edg
ed R MU
til be ns
eith e
d
inpu E th ST
ep at th HOLD er inand/
ts ey ca be
is hee sa th pu or P
MU n
ST be
ard, me e O t 2 or hoto
MO
Le
tim PE
be
TO
R MO lear
4.LE by bearn
e
N 3. Cell
n m on & S
ca
TIO
ep mod
se D
n
N
od Mat TO
fo ns s W ing. e la
e be rix P
sts
5.P operr BO or on ILL
gins 1
for
at TH M be
to re
5 m CLOSE
.
be le ss ors M C-2 O
in.
Inpu ep arn STO are C-200 00. N for
in
se
in
us
P
LE
ea
ts g st ns bu ed s w D ch
dica
are op or tto .
he s W de
ted
n du IL te
no s. s an n ag
w
ct
L
En
d
ai
al
ed
MO
be
en n
tr
d le with
ON
NIT
arn in
OR
Inpapm
mod5 m
ED
uts ent
.
e, in.
M
r
we
Po
MO
TO
R
To
AL
IT H
LIM ITC
SW
RY
TE K
BAT PAC
R
TO TS
MO PU
IN
A
RM
PW G ed
WR GN R1 ND
21 DV2
V-
22 AWG Min.
3-conductor twisted
pair, shielded cable
3
JO
M
LE AX
LE G
D
FT JO
ON
RIGG
HT
1615 14
3
2
1
13
12
4
5
SeERD
nsi
tiv
ity
ER
D
M
Ov otor
erL
oa
d
Primary/Single
External
Open/Close
Key Switch In a
Secure Place
3 Wires to Key Switch
3 Wires to Key Switch
37
Adjustments
open and close limits
The limit sensor activators MUST be
installed on BOTH ends of chain to
indicate the OPEN and CLOSE positions
of the gate or DAMAGE will occur. They
will activate the corresponding LIMIT
SENSOR (Gray or Black) when they
move within range, stopping the gate at
the desired positions.
The limit sensors have been FACTORY
INSTALLED for front mounting position.
If rear mounting position is being
installed, make sure the limit sensors
have been moved to the correct
positions (see below).
IMPORTANT: LEDs MUST light up when gate
reaches OPEN and CLOSE positions or operator
WILL NOT learn gate positions. If gate positions
are not learned, gate cycling speed will remain
slow during normal operation.
te
Ga et
k
rac
B
Limit Sensor
Activator installation
Plu
g
Plu
g
Limit Sensor
Activator
(Magnet)
te
Ga et
ck
Bra
BLACK Limit Sensor
Plu
g
IMPORTANT: Cycle the gate OPEN and CLOSED AFTER the
limit sensor activators have been installed. Operator will cycle
slowly to LEARN the open and closed gate positions. After
the operator learns the gate positions, it will cycle at the
GATE SPEED selected for normal operation, see page 28.
LED lights when
sensing a limit
sensor activator
(Magnet).
GRAY Limit Sensor
NOTE: Refer to
page 40 for Limit
Sensor wiring.
Back
View
Back
View
Limit Sensor
Activator
Factory Installed
GRAY Limit Sensor
Factory Installed
BLACK Limit Sensor
Limit Sensor
Activator
Reposition GRAY
limit sensors
to aligned
with chain. BLACK
Limit Sensor
Activator
Limit Sensor
Activator
Front Mounting Position
IMPORTANT:
Gray Limit sensor
MUST be in the
OPEN position.
Rear Mounting Position
“Fine Tune” Limits Adjustment
PhotoCell Edge Limit SW
Edge MATRIX
UL
ON-LINE
Entrap
Motor Controller
15 14 13
16
12
ERD
LED ON
3
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
MC-200
MAX
2
1
POWER
4
JOG JOG
LEFT RIGHT
5
ERD
Motor
OverLoad
Sensitivity
Push and HOLD the JOG LEFT or JOG RIGHT buttons
accordingly on the MAX MC-200 motor controller to
move the gate (release the button to stop gate). This
allows gate to be moved back and fourth without leaving
the operator to “fine tune” the open and close gate
positions if desired.
WARNING: Avoid moving gate while “Fine Tune” adjusting.
38
IMPORTANT: Remove breather pin from
gear reducer BEFORE cycling operator.
Breather Pin
N
IO
UT
CA MOVE
RE RE
FO
BE TION
RA
E
OP
Adjustments
reverse sensor (erd)
The MAX 1500 / MAX 2200 is equipped with an ERD Sensor - Electronic Reversing Device (Type A) that functions as
entrapment protection according to UL 325 standards. The gate will reverse direction after encountering an
obstruction in either the OPEN or CLOSE gate cycle.
When the gate encounters an obstruction during the CLOSE cycle, it will reverse to the open position and PAUSE the gate.
An input command (press remote button or exit loop activation) is needed BEFORE the gate will reset and close again.
When the gate encounters an obstruction during the OPEN cycle, it will reverse approximately 6 inches and PAUSE the gate.
An input command (press remote button or exit loop activation) is needed BEFORE the gate will reset and open again.
For the ERD Sensitivity to function correctly:
• Limit sensors MUST be learned BEFORE adjusting the ERD Sensitivity.
See previous page if you have questions about how limit sensors are learned.
PhotoCell Edge Limit SW
POWER
Edge MATRIX
UL
ON-LINE
Entrap
Motor Controller
15 14 13
16
12
ERD
LED ON
3
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
MC-200
MAX
2
1
4
JOG JOG
LEFT RIGHT
5
ERD
MA
TRIX
Motor
OverLoad
MA
DE
1
BACKBATT
-UP ERY
LEAV MOD
in US
A
LEAV
OPENE
AU
TO
MA
TIC
AN
TAIL TI
GATE
EXIT
Sensitivity
PRIM
GATEARY
OP
1 TIMEN
E
OP
LEFTEN
/CL
O
SE
EXIT
OFF
ER
CO
16 sensitivity setting positions.
C
D
OB
BLACD PORT
K BO
X
STRI
GN KE
KEYPD
AD
GN
D
/ RD
PH
R
OTOC
GN
ELL
D
ENTR
AP
ION
D
CLOS
REVE
RSE
E
SENS
ITIVIT
MO
TOR
Y
OVER
LOAD
NO
LIM
CLM
SW
AMOITTO
P SL ITC
IPPR H /
ING
OPEN
CO BA
CLOS MPACKTTERY
E
SW LIMIT
ITC
(+)
GN
D
(-)
BATT
ER
IN US Y
E
24V
GN
D
GN
D
(-)
SE
GATEC
1
2
UL
AL
ALARARM 12
M V
RESERET
GN T
D
GATE
PST
ow
ATer
USIn
LIM
SW IT
ON ITCH
-LINE
MO
PRIM ON-LITOR
NE
GATEARY
(+)
EDGE
EDGE
ID PL
ERROUG
R
OP
EN
STOP
CLOS
E
CO
M
GATE
DISA
BLE
RA
DIO
SIG.
RA
DIO
GN
D
FIR
GN E DEPT
D
MA
GN X OPEN
D
SPEE
MA
X
Ph
oto
PHOT
OCEL
L
UL
MOT
STOP
Ce
PO
ll Ed
W
ge
MC ER
Lim
Mot -2
2 it SW
or 00 UL
Con En
1
tro trap Edge
lle
MA
r
ON TR
H
POW
ER
)- 5 (+ (-) 48 5 ND RS- S-48 G 24V
R
R
PW
IX
R D
AT R
M OA
B
-LI IX
NE
JO
M
LE AX
LE G
D ON
FT JO
RIGG
HT
1615 14
3
E
13
12
4
5
1/2
SeERD
ns
itiv
ity
F
ON
/O
Ba FF
tte
ry Repla
Ba ce
tte
ry
ER
D
M
Ove otor
rLoa
115V
Sensitivity
MIN
OR
OPEN
M
R
ERD
r NO
COM
Tam GND
per
IN
LA
A
5
Tam
pe
R
TO S
O T
M PU
IN
4
MAX
GATE
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
3
MOT
PO
RECOSITION
RD
ER
C
D
LED ON
ON
MAG
LOCK
COM
NC
GA
TAM TE
PER
12VD
GN
24VD
MAX
AX
X
2Sec
TY
OFF MA
X
TIM
ER
PART
OPENIAL
GN
A. Turn knob until blue LED lights up.
Max sensitivity reached, Position 1.
“1” - Maximum sensitivity setting.
Too sensitive for most gates. (LED lights)
“16” - Minimum sensitivity setting.
Not sensitive enough for most gates. (LED is off)
MAG
DELALOCK
Y
1.5
Sec
MIN
NO mechanical hard stop for knob.
1 14 13
15
16
1
6
12
RO
LS
SAFE
Y
CLOS
E
ID
PLUG
Adjusting ERD Sensitivity
OFF
NT
CENT
ER
SAFET
OP
RIGHEN
T
EN
ON
CENT
E
CLOS E
ED
OP
FU
Ba
TE
ST
Ba
tte
ry
tte
ry
t
pu
t In
ec
Sel ge or
lta
Vo AC
5V
11 AC
0V
23
d
IN
PW
R
Er IN
ror
m
.U
ax
w.M
ww
o
S.c
WER
PO
AC
Mo
du
le
SE
p
7 Am Amp
15
id
On
Off
ro
X
MA
To
G
NIN
AR
W
!
MAX
N!
TIO
TEN
AT
15 14 13
16
12
LED ON
3
4
5
!
H
E
HIGAG
LT r
VO nche
B. Turn knob counter-clockwise to reduce
sensitivity during ERD testing as needed.
(LED remains OFF for all but position 1)
V
H
E
HIGAG
OLT nect
on fore
disc be unit
wer g
po icin
rv
se
L
I
M
I
T
S
E
N
S
O
R
t n
'bra ie
de avan
tret
l'en
ERD
Sensitivity
Testing ERD Sensitivity
Allow the gate to strike an immobile object while OPENING and
CLOSING. The gate MUST reverse direction after striking the object.
Increase or decrease the ERD Sensitivity as needed. Repeat this
process until the correct sensitivity is achieved. If alarm sounds
while preforming this procedure,
Matrix 1
press STOP BUTTON on Matrix 1
MOTOR MOTION
or externally mounted Alarm
Reset button to shut-off alarm.
OPEN
STOP
CLOSE
IMPORTANT: When satisfied with ERD adjustment,
cycle the gate 3 or 4 times to make sure that the ERD
sensor does not falsely trigger during normal gate
operation. Readjust if this happens.
Alarm
Reset
Button
“Min” ERD Position 16 Setting
When solid gates are installed in:
• Unusually high wind areas
• Uphill opening gate
• Heavy gate
• Cantilever type gate
ERD sensor can be set to Min (position 16)
to keep the gate cycling normally in such
extreme conditions.
CAUTION: Minimum sensitivity setting
(position 16) results in gate exerting
MAXIMUM force before reversing direction.
39
Maintenance
max 1500 / 2200 primary/single wiring schematic
MATRIX 1
BATTERY
BACK-UP MODE
Solar Panel 24V
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
“Optional”
MAX Solar
Power Kit
CENTER
PHOTOCELL
UL
EDGE 1
ENTRAP
EDGE 2
Solar
Panel
Electronics
Box
MAX
OFF
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
OBD PORT
BLACK BOX
24VDC
STOP
MAX
GATE SPEED
MIN
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
GND
RADIO SIG.
to POWER/SOLAR IN
GND
OPEN
MAX Toroid 15 Amp Box
AC
Select Input
Voltage
115VAC or
230VAC
IN
Input AC Power
115VAC or 230VAC
MIN
CLOSE TIMER
115V
SAFETY
Black
POWER
White
FUSE
On
www.Max.US.com
Off
Green
7 Amp
MAX Toroid 15 Amp
Gate
Shut-Off
O Switch
I
www.Max.US.com
Motor
POWER
IN
Battery
Pack
TO MOTOR
CONTROLLER
Electronic Gate
OPEN/CLOSE
MAX BC-7
Battery Module
POWER/SOLAR
IN
BATTERY
IN
Alarm
Reset
Button
Alarm
MAX MC-200
Motor Controller
Sensor
Gray
40
Sensor
Black
GND PWR 24V -
RS-485 (-) -
PACK SWITCH
RS-485 (+) -
INPUTS
GND PWR 12V -
Limit
not used not used -
5-Pin
4-Pin
3-Pin
6-Pin
2-Pin
3-Pin
MOTOR Power In MOTOR BATTERY LIMIT ALARM
Limit
MATRIX 1
Maintenance
max 1500 / 2200 secondary wiring schematic
Solar Panel 24V
“Optional”
MAX Solar
Power Kit
Solar
Panel
Electronics
Box
115V
AC
Select Input
Voltage
115VAC or
230VAC
IN
Input AC Power
115VAC or 230VAC
to POWER/SOLAR IN
4-Pin
Not Used
MAX Toroid 15 Amp Box
Black
POWER
White
FUSE
On
www.Max.US.com
Off
Green
7 Amp
MAX Toroid 15 Amp
Gate
Shut-Off
O Switch
I
www.Max.US.com
Motor
POWER
IN
Battery
Pack
TO MOTOR
CONTROLLER
Electronic Gate
OPEN/CLOSE
MAX BC-7
Battery Module
POWER/SOLAR
IN
BATTERY
IN
Alarm
Reset
Button
Alarm
Sensor
Gray
GND PWR 24V -
RS-485 (-) -
RS-485 (+) -
MAX MC-200
Motor Controller
GND PWR 12V -
MOTOR BATTERY LIMIT ALARM
PACK SWITCH
INPUTS
not used not used -
5-Pin
4-Pin
Limit
3-Pin
MOTOR Power In
Limit
6-Pin
2-Pin
3-Pin
To “SEC GATE” input
on Matrix 1
MATRIX 1
Sensor
Black
41
maintenance
qualified gate operator technician
Maintenance and repair of the gate operator must be preformed by a qualified professional gate operator technician.
The following services need to be periodically performed:
• Turn ON the Gate Shut-Off Switch BEFORE performing any maintenance.
• Check and adjust the gate operator’s force, speed, and sensitivity.
• Make sure all power (AC/DC) connections are corrosion free.
• Check all batteries for proper voltage.
• Check the incoming line voltage and confirm it is within 10% of its rating (115 or 230 volts).
• Verify battery backup functionality by turning off the power source (115 VAC and 230 VAC). Restore power after
testing.
• Check that chain is not too loose and remove chain links if necessary. DO NOT make chain too tight.
• Check wheels, guide rollers and chain and lubricate with heavy-duty, high-performance lubricant where needed.
• Check V rail for signs of cracking or separation from ground.
• Test all contact and non-contact sensors, in-ground vehicle loop detectors, keypad, telephone entry system or any other access
control devices that are used to control the gate operator.
• Test the manual release feature.
MAKE SURE END USER/HOME OWNER KNOWS HOW TO PROPERLY REMOVE GATE OPERATOR FROM SERVICE AND WHO TO
CONTACT FOR PROFESSIONAL ASSISTANCE.
Date Installed:
Installer/Company Name:
Phone Number:
Operator
Serial Number:
end user / homeowner
Any repairs and modifications must be preformed by a qualified professional gate operator technician. If the gate or gate
operator ever malfunctions, end user/home owner needs to immediately remove the gate operator from service (manually
position gate (see manual release) in a desired prolonged position and turn ALL power OFF to the gate operator). End
user/home owner must call a qualified professional gate operator technician for any repairs and modifications.
The gate operator is virtually maintenance free to an end user/home owner, minimal maintenance is recommended to ensure
reliable operation.
End user/home owner:
• Scheduled maintenance should be performed approximately every six months by a qualified professional gate operator
technician, or when unusual noises are heard from the wheels, chain, guide rollers and/or gate operator.
• DO NOT remove the operator cover to perform any normal maintenance.
• Lubricate wheels, chain, guide rollers periodically with heavy-duty, high-performance lubricant and clean up all excess
lubricant.
• Make sure there are no vehicles or pedestrians in the path of the gate while performing maintenance.
• Make sure the person performing maintenance is the only person in control of all control devices in order to avoid possible
involuntary activation of the gate operator. Gate operator MUST be removed from service while maintenance is performed.
• Keep any water from landscape watering hoses or sprinkler systems away from the gate and gate operator area.
• Keep the area around the gate and gate operator as clean as possible.
• Keep any debris away from the gate’s moving path.
• Test periodically (use caution) all safety sensors, in-ground vehicle loop detectors, keypad, telephone entry system or any
other access control devices that are used to control the gate operator. Make sure everything is working properly.
• Solar panel must be cleaned periodically if solar power is being used.
42
maintenance
electronic gate open / close
1
Slide door open
and insert key.
2
Turn and HOLD key
either way for
reversible gate
directions.
CAUTION: Keep pedestrians and vehicles
clear of the gate while it is moving.
NOTE: The gate cannot be manually pushed open.
mechanical gate release (manual release)
The chain is mechanically dropped to manually release the gate. The GATE SHUT-OFF SWITCH MUST be turned ON before
dropping the chain (See 1 below). Dropping the chain without turning the Gate Shut-Off switch ON will activate the ALARM
and GATE TAMPER feature, See page 36 for complete information about Gate Shut-Off switch operation.
Optional MAX Chain Release
Preform 1 .
ON
Insert key and turn
to unlock chain.
F
OF
1
Slide cover door open.
Turn Gate Shut-Off switch ON.
Gate chain can be dropped
without the ALARM activating.
The GATE TAMPER relay WILL
be activated.
Ga
te
Bra
cke
t
Press down
lever to release
chain.
See page 51 for more
information about MAX
chain drop mechanism.
43
maintenance
audible alarm
If the Alarm Sounds During Normal Gate Operation:
When the gate encounters TWO consecutive
obstructions before completing a gate cycle, the alarm will sound and the gate will PAUSE in the position where the second
obstruction occurred. CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the alarm reset button on the operator
to shut off the alarm and reset the gate. NOTE: Alarm will automatically shut-off after five minutes but will not allow gate to
operate until the alarm reset button is pressed.
Some reasons why the alarm sounds:
• A FOREIGN OBJECT is on the gate frame while the gate is moving.
• The gate is TOO HEAVY.
• Debris is on the gate rail such as mud,
rocks dirt etc. and gate CANNOT move freely.
• WHEELS are NOT ON GATE RAIL
and gate CANNOT move freely.
• WHEELS are BROKEN and gate
CANNOT move freely.
Gate is
Closing
• The gate is HITTING a VEHICLE.
Alarm Reset
Button
• The gate operator tries to close the gate but gate
gets CAUGHT on an object and cannot complete
a gate cycle.
44
maintenance
replacement parts list
Item
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MAX 1500/2200 Cover with Lock and access door
MAX 1500 1/2 HP Brushless DC Motor
MAX 2200 1 HP Brushless DC Motor
MAX 1500 Gear Reducer for 1/2 HP Motor
MAX 2200 Gear Reducer for 1 HP Motor
Cover Locking Bracket
Output Sprocket
Roller Sprocket/ Idler Wheels
BLACK Limit Switch Sensor
GRAY Limit Switch Sensor
Matrix 1 Control Board Assembly
MAX MC-200 Motor Controller Assembly
MAX Toroid 15 Amp Box
Main Chassis
MAX BC-7 Battery Module (7 AHr)
Single Gang Electrical Boxes
1
2
MAX 1500
4
3
MAX 2200
5
6
7
8
W
PO
OL
/S
ER IN
Y
ER
TT
BA IN
AR
ww
w.M
ax.
US
MC
To R IN
WE
ry
tte
Ba ck
Pa
1/2
ER
W
PO IN
Vol
E
OR
OT ER
M LL
TO RO
NT
CO
Bat
tery
.co
m
tag
e
PO
F
ON/
OFF
Batt
ery Rep
lace
Batt
ery
MA
X BC
Batt
ery
TES
Batt T
ery
15
MC ck
To Pa
ry
tte
Ba
-7
Mod
ule
Batt
ery
Erro IN
r
9
MAD
E in
IX
1
BACBATTER
K-U Y
P
USA
LEAV MO
LEAV
DE
OPENE CLOS E
ED
AU
EXIT
OPE
LEFTN
OP
OFF
EXI
EN
/CLO
ON
ER
10
PRI
MA
GAT RY
E
OPEN
1 TIME
TO
MA
TIC
ANT
TAI I
LGA
TE
CENT
T
OPE
RIG N
HT
SE
CEN
SAFE
CO
MA
GLO
DEL
OFF
NT
1.5S
RO
TER
CK
AY
ec
2Sec
LS
TY
SAF
MIN
CLO
ID
PLU
MA
LOCG
K
ETY
COM
OFF MAX
SE
NC
GAT
TAM E
PER
TIM
ER
G
Tam
per
NO
COM
Tam GND
per
IN
PAR
TIAL
OPE
N
12VD
C
X
GAT
RADIO GND
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
TIO
N
PHO
TOC
ELL
STO
P
ED
CLO
REVE
RSE
SE
SENS
MOT
ITIVI
OR
TY
OVER
NO
LOAD
LIMI
CLAM T
SWIT
P SLIP
CH
PING/
LIM
SWI IT
ON-LTCH
INE
MOT
UL
GAT
STA E
TUS
EDG
E1
EDG
E2
ID
PLU
ERR G
OR
ALA
ALA RM
RM 12V
RET
RES
ET
GN
D
PRIM ON-LOR
ARY INE
GATE
OPE
N
COM
CLO
SE
SEC
GATE
(+)
GND
(-)
11
ENT
RAP
N
E SPE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
UL
MO
OPE
MA
MIN
MAX
OPEN
STOP
CLOSE
COM
GATE DISABLE
OBD
BLA POR
CK T
BOX
RADIO SIG.
MO
TOR
POS
REC ITIO
OR N
DER
24VD
C
BAT
TER
IN Y
USE
24V
GND
GND
GND
14
utut
Inp
ttInp
lecee
lec
Setag
Se
or
tag or
115V
115V
MA
TR
CC
VolVA
Vol
VACC
115VA
115
VA
230
230
POW
ER
.US
AC
AC
m
.co
ax
EE
FUS
FUS
IN
IN
ww
w.M
RR
WE
WE
PO
PO
pp
p
Am
77Am
Am
15
d
On
On
Off
Off
R
”
R
TO S
MO UT
INP
ON
P
-
V
24 D
V -
-
X
RI
PW
AT
M
R
RS
RS -4
85
-4
85 (+
)
GN (-)
W G
R N
12
D
-
-
-
M
1
n
-
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
N: N:
IO IO
UT NT
CA TE
AT
3
JO
MA
LED X
LEFG
ON
T JO
RIGG
HT
1615 14
3
2
1
13
12
4
12
BATT
PAC ERY
K
SWITLIMI
T
CH
n
AR
or
tio V
AL
tio
1
ec 12
ec es GE
ot R
ot
pr
t PW
Pr lin ED
t de d to . .C.) ch rs
en 00
en Gui re ction (N to ea erato
pm -2
ed
,
wi
us
n
tra MC
pm or be fun ED LY op
ca
al
en th
T
be tra
ll
r wi
ns ST NO OS ON du
ST En
Ce
we s
Se MU L CL ors en
. to
MU
po or
IL LY
oto uts ed
ns
or W AL ns wh
V
GND
LY se
Ph
se 00
ns r
12
r Inp us
MC
3 be
se ato RM D -2
R
d/o
-20
s.
A
• oper NOTORE MC
0
an the ST or in
PW
Slid
r’s
ire
ge of MU ns ma r.
00
e
.
Y
W NI
-2
s.
• MO erato ed Ed AN V D se re occu
12
MC
on .
op e us rsing to R RE ST ll
cti ion
wi
ar ve red
TO MU lt
tru lat
d
PW NI
re g
uts fau
ins nstal
Re wi
• be -200 MO inp or
ito in
ion d’i
r
on rs ge
d
lat e
MC we ED ED
M ve Ed
re o • po
tal tic
US ER
R
ins no
O
UN MP
e ir la
• JU
Se Vo
1
t SW
MAT
ON- RIX
LINE
13
ED
Limi
2
Edg 1
e
RN
ll Edg
e
E G
dg N
e D
1
MC
R
Mo -20
tor 0 UL
Co Entr
ntro ap
ller
EA
tra Inpu
En
toCe
roi
To
Po
we
r In
“L
Re
ito ot ll
be
be
be
be
. :
on Ph Ce
ST
3 ST y can ST
M
ors &
can
MU
MU
3 sens 2 rs the MU ll
Ce
uts
RE
&
OP 1
2 OR uts nso FO inp oto
s.
3. ST
inp Se
d
Ph
uts NIT N ED BEuse
r or & trix gin
2
d/o ut EN Ma be
Inp MO AR OR uts un
on de
an
to LE NIT inp y
inp OP e mo
to An
ge er
To
the tim rn
MO ed d. .
Ed
1. wir rne red g eith LD e lea
, ION
Jo
ted
lea pe sin to HO sam
jum ver ed d the ard MOT
SE
ica
Jo g
he OR
CLO
ted ON
Re wir an at is
g LT
. ind
MOT
2. be ss
tec
RT
ns ep
OP min de be
Pre tto
.
3. bu til be
ST 5
ch LL
for
Ph Ed
min ,
ea WI al
un
EN ts
5 de
ot ge
for Ds du
OP las
hin mo
o
LE en
ON 0. wh
de .
wit rn
Ce 2
mo ing be -20 0s
ain lea
ll
.
d
2
arn ep LL MC -20 d. ag en
n
ED
Le be WI on MC use n d
3
tto
OR
tio per
by Ds
are bu s an
LE sor TH s
NIT
ec m ts
4. sen BO tor OP sor
ot ju pu
MO
for era ST sen ps. w
in
Pr
op ss rn sto no
t ST ed
Pre lea ing
5. to ep are
en : MU us
be uts
pm ts un
Inp
MO
TO
Pho
PO
WE
X
MA
5
ER
Sen
D
sitiv
ity
ER
D
Mo
Ov tor
erL
oad
16
45
max 1500 / 2200 warranty
Maximum Controls LLC (“Manufacture”) warrants the original purchaser of this
product, for the purpose to which this product is originally installed, that the product is
free from defect in materials and/or workmanship for a period of 8 years for the
Brushless DC Motor and cover, 5 years for everything else with the exception of the
batteries which are limited to a 1 year warranty. The performance of this product is
dependent on compliance to the instructions, maintenance, operation, and testing
clearly outlined in the user manual. Failure to comply completely with those instructions
will void this warranty in its entirety. This warranty does not cover damage to the
product caused by vandalism, water damage, direct hit lightning strike, or installation
errors. This warranty does not include any labor charges that might be needed to
troubleshoot, replace, or repair a problem.
If, during the limited warranty period, one of the components exhibits a defect in
material and/or workmanship, please call 949-699-0220 before dismantling the product.
Shipping instructions and an RMA (Return Material Authorization) Number will be
issued by the factory service center when contacted. Do not send any product in for
service without an RMA number. Shipping charges to and from the factory service
center for warranty repairs are the responsibility of the customer. Repair or replacement
of any warranty items is made at the sole discretion of the Manufacturer.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO
ANY WARRANTIES OF MERCHANTABILITY AND SUITABILITY FOR A PARTICULAR
PURPOSE, ARE LIMITED TO 8 YEARS FOR THE BRUSHLESS MOTOR DC AND COVER,
5 YEARS FOR EVERYTHING ELSE WITH THE EXCEPTION OF THE BATTERIES WHICH
ARE 1 YEAR. NO IMPLIED WARRANTIES WILL EXTEND BEYOND THE WARRANTIES
LISTED ABOVE. Some states do not allow limitations on how long an implied warranty
last so this limitation might not apply to you.
This Limited warranty does not cover any problems with or relating to, the gate, the gate
hardware, including but not limited to hinges, rollers, brackets, entry devices etc. Any
service call that determines the cause of a problem to be external to the product could
result in a fee. Under no circumstances shall the manufacture be liable for
consequential, incidental or special damages arising in connection with the use, or
inability to use, this product. Under no circumstances will the Manufacture’s liability for
breach of warranty, breach of contract, negligence or strict liability exceed the cost of
the product covered other liability in connection with the sale of this product.
46
options / unique Features
“Like NO other Gate Operator in the World”
gate tamper feature
The GATE TAMPER feature will activate the relay when a number of security circumstances occur, making illegal entry almost
impossible when the gate operator is connected to a existing building/home alarm system. The GATE TAMPER relay will activate
when:
EX
TR
EM
Ef
orc
e
The gate is PHYSICALLY
moved with EXTREME force
from closed gate position.
The chain is disconnected and dropped
when the gate is in the closed position.
The FIRE switch is turned ONLY if
the GATE DISABLE has been turned ON.
47
options / unique Features
“Like NO other Gate Operator in the World”
magnetic dynamic brake system
This unique built-in feature controls the gate’s open and close stopping positions. When a gate is installed on a slight incline or
decline, gate coasting can be a concern. When the motor stops, the momentum of a heavy gate can continue coasting beyond
the gate’s stopping position. This can be a problem, especially when closing bi-parting gates meet. The MAX 1500 / 2200 WILL
NOT ALLOW gate coasting beyond it’s learned stopping position, even when the gate is installed on a slight incline or decline.
Other Gate Operators
Other gate operators can coast when motor
stops, causing gates to hit each other.
MAX 1500 / MAX 2200
MAX 1500 / 2200 WILL NOT ALLOW gate coasting.
Gates stop at the same position every time.
Gear Reducer
This feature does NOT allow the gate to be manually pushed open by
multiple people. It takes several thousand pounds of force to physically
move the gears on the gear reducer. Even if several people try and
push the gate open, the gear reducer ratio will prevent gate movement.
If the gate does move, the GATE TAMPER feature will activate and the
proper authorities can be automatically notified if desired.
The gate WILL NOT
move using human force.
48
options / unique Features
“Like NO other Gate Operator in the World”
partial open feature
This feature controls a long gate’s normal open and close stopping positions compared to emergency situations that require
the gate to ALWAYS FULLY OPEN. It is important to have FULL ACCESS in time of emergency but this occurs much less than
the normal daily operations. MAX operators will EASILY operate in either circumstance. A long gate may not need to fully open
to allow normal access, especially in high traffic areas where gate cycling time can be reduced between vehicles and still allow
normal daily operations to occur. Time between vehicles can be greatly reduced, not to mention all of the benefits that occur
when using PARTIAL OPEN.
• Less wear and tear on the gate operator.
• Less maintenance and repairs.
• Less power consumption.
• Less time between gate cycles.
• Better access control of the area.
• Better security of the area.
- Partial Open -
- Fully Open -
Partial Open turned ON
Normal Daily Access
Partial Open turned ON
Emergency Access
Any Normal Opening Input
on Matrix 1
FIRE DEPT Input or
MAX Input on Matrix 1
49
options / unique Features
“Like NO other Gate Operator in the World”
Gate disable feature
This unique GATE DISABLE feature is useful when the gated area needs to be secured from ALL but emergency and/or authorized vehicle entry. Some examples are:
• Residential home vacation period.
• During closed hours of a business.
The GATE DISABLE feature will allow the FIRE DEPT/MAX and
RADIO inputs to operate but nothing else. It helps with some
major security problems that can occur when no one is
available to monitor the property.
GATE DISABLE
prevents breaking into
a keypad box and
trying to trigger the
wires to get the gate
to open.
M
Pl etal
at
e
GATE DISABLE
prevents trying to
trigger the exit loop
to get the gate to
open.
EX
IT
LO
OP
IMPORTANT: It is NOT recommended activating GATE DISABLE while persons are present inside the property.
event history download
Event History Text Document Sample
Event type clarificaon:
This unique EVENT HISTORY feature has an On Board Diagnostics (OBD)
port to download a simple .txt file to troubleshoot gate operator errors
and to view normal transaction logs. This file will log intermittent
problems with the gate operator that can be difficult to solve. This file
can even be e-mailed to the factory from out in the field at the job site for
additional technical support if necessary.
The event history can store up to 1000 transactions.
USB Flash Drive
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
ANTI
TAILGATE
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Event Report:
Fri 07/11/2014 10:59:41
INFO : Cycle Counter
Fri 07/11/2014 10:59:41
ENTRAP : SEC_MC: First ERD Detected
Fri 07/11/2014 10:59:37
INFO : Radio Input Deacvated
Fri 07/11/2014 10:59:36
INFO : Radio Input Acvated
Fri 07/11/2014 10:58:54
INFO : PRI_MC: Fully Open Posion Learned
Fri 07/11/2014 10:58:53
INFO : SEC_MC: Fully Open Posion Learned
Fri 07/11/2014 10:57:40
INFO : PRI_CIO: Communicaon Established
Fri 07/11/2014 10:57:38
ENTRAP : PRI_MC: Photo Cell Deacvated
COM
NC
Fri 07/11/2014 10:57:34
ENTRAP : PRI_MC: Photo Cell Acvated
Tamper NO
COM
GND
Tamper IN
Fri 07/11/2014 10:57:21
INFO : Radio Input Deacvated
Fri 07/11/2014 10:57:21
INFO : Radio Input Acvated
AUTOMATIC OPEN/CLOSE CONTROLS
EXIT
INFO: informaonal message only
WARNING: unusual event but doesn't cause system malfuncon
ERROR: abnormal event, could cause system malfuncon
ENTRAP: entrapment detecon event
CENTER
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
Fri 07/11/2014 10:56:46
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2014 10:56:36
INFO : SEC_MC: Fully Open Posion Unknown
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
N
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
GATE
STATUS
Fri 07/11/2014 10:56:36
INFO : PRI_MC: Fully Open Posion Unknown
Fri 07/11/2014 10:56:36
WARNING: PRI_MC: Tamper Reported
BATTERY
IN USE
US
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Acvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Acvated
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
RADIO SIG.
GND
50
OBD PORT
BLACK BOX
OPEN
COM
CLOSE
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
options / unique Features
“Like NO other Gate Operator in the World”
max chain release mechanism - optional
Maximum Controls offers a MAX chain release mechanism that can provide an easy MANUAL gate release for slide gate
operators. It can be installed on any sliding gate that uses a chain drive. This allows a user to quickly drop the chain without any
tools to MANUALLY move the sliding gate to an open position.
Gate in Closed Position
MAX
Chain Release
Installation
Position
Installs on the end of the gate nearest
the gate operator when the gate is
closed. Bolt to the gate bracket.
Ga
te
Bra
c
ket
n
hai
XC
MA lease
Re
Insert key and turn to unlock chain.
Press lever down to release the chain.
51
52
53
www.max.us.com
CONFORMS TO UL STD 325
UL CLASS - I, II, III, IV
SAFETY SENSORS REQUIRED
CERTIFIED TO CAN/CSA STD
C22.2 NO. 247
Residential/Commercial
Brushless DC Slide Gate Operators
Made in USA
4009963
Maximum Controls LLC.
27211 Burbank
Foothill Ranch, Ca 92610
Tel: (949) 699-0220
MAX 1500/2200 Slide Version 7.3.16