programmable dc electronic load model 6310a series

programmable dc electronic load model 6310a series
Programmable
DC Electronic Load
MODEL 6310A SERIES
Key Features:
PROGRAMMABLE DC ELECTRONIC LOAD
MODEL 6310A SERIES
Chroma Programmable DC Electronic Load
6310A series is suitable for the test and
evaluation of multi-output AC/DC power
supply, DC/DC converter, charger and power
electronic components and good for application
in areas such as research and development,
production, and incoming inspection. The
system is configured by plugging the user
selectable load modules into the system
mainframe, and operated using the keypad on
the front panel of the instrument or the remote
controlled instructions via RS-232C, USB or
GPIB interface.
The 6310A series offers 8 types of modular
loads with power ranging from 100 watts to
1,200 watts, current from 0.5mA to 240A,
and voltage measurement from 0.5mV to
500V. Each load is isolated and floating,
programmable in dual current range and
measuring voltage range, and capable of
synchronizing with other modules for control
operation. The load can be operated in
constant current, constant voltage, constant
power and constant resistance.
USB
The 6310A series can simulate a wide range
of dynamic loading applications. The loading
waveform is programmable in slew rates,
load levels, duration and conducting voltage.
Furthermore, up to 100 series of system
operating status can be stored in EEPROM
and recalled instantly for automated testing
application.
Real time measurement of voltage and
current is integrated into each 6310A load
module using a 15-bit precision measurement
circuit. The user can perform on line voltage
measurement and adjustment, or simulate
short circuit test using the simple keypad
on the front panel. Additionally, the 6310A
series offers an optional remote controller for
automated production line.
The 6310A series has self-diagnosis routine
to maintain instrumental performance all the
time. It is also protected against OP, OC, OV,
OT, and reverse polarity to guarantee quality
and reliability for even the most demanding
engineering testing and ATE application.
GPIB
RS-232
■ Max Power: 200W, 100W×2(Dual),
30W & 250W, 300W, 600W, 1200W
■ Wide range 0~500V operating voltage
■ High compatibility between 6310 and 6310A
■ Up to 8 channels in one mainframe, fit for
testing multiple output SMPS
■ Parallel load modules up to 1200W for
high current and power application
■ Synchronization with multiple loads
■ Flexible CC, CR, CP and CV operation
modes
■ Dynamic loading with speed up to 20kHz
■ Fast response of 0.32mA/us~10A/us
slew rate
■ Minimum input resistance allowing load
to sink high current at low voltage
■ Real time power supply load transient
response simulation and output
measurement
■ User programmable 100 sequential front
panel input status for user-friendly operating
■ High/Low limits of testing parameters to
test GO/NG
■ Digital I/O control
■ Over current protection (OCP) testing
function
■ 15-bit precision voltage and current
measurement with dual-range selection
■ Remote sensing capability
■ Short circuit test
■ Self-test at power-on
■ Full Protection: OV, OC, OP and OT
■ USB, GPIB & RS-232C interfaces
Versatile System Configuration
Chroma 6310A Programmable Electronic Load integrates
microprocessing capability into each load module and
mainframe as the system operates in parallel processing
mode to optimize the speed and control among multiple
load modules. All load modules are configured to work
synchronously, and testing can be carried out simultaneously at
multiple output to simulate real life application.
6310A System Block Diagram
Module Load Design
The Chroma 6314A 1200W and 6312A 600W electronic load mainframes
accept the user-installable 6310A series load modules for easy system
configuration and fit 19" instrument rack. The 6314A holds four 63102A
load modules at most to offer 8-channel 100W input load with standard
front-panel inputs. It fits for testing multiple output switch power supply.
Additionally, GO/NG output port is useful for UUT's pass/fail judgement on
automated production line. All modules on the 6314A/6312A mainframe
share a common GPIB address to synchronize and speed up the control of
load modules and read-back of operating data.
Series Interface
Series Interface
Series Interface
Series Interface
Series Interface
RS232
INTERFACE
Application of Specific Load Simulation
Series Interface
Series Interface
GPIB
INTERFACE
USB
INTERFACE
DIGITAL I/O
CONTROL
Series Interface
The 6310A load modules operate in constant current, constant voltage,
constant power or constant resistance to satisfy a wide range of test
requirements. For example, the test of battery charger can be simulated
easily by setting the load to operate in constant voltage.
V
V
Series Interface
Constant Resistance Mode
Constant Current Mode
Compatibility WITH 6310 SErIES
The 6310A series load modules are compatible with the
6310 series mainframes and vice versa. However certain
new features and functions will not be available when using
the 6310A modules in the 6310 mainframes as well as 6310
modules in the 6310A mainframes. This allows users to save
on new equipment cost.
I
I
V
V
I
I
Constant Voltage Mode
Constant Power Mode
Each load module is designed with state-of-the-art technology and
connects all power MOSFET devices parallel to insure high accuracy
load control with minimum drift of less than 0.1%+0.1%F.S. of the current
setting. The FET technology accomplishes minimum input resistance
and enables the load to sink high current even at very low voltage. For
example, model 63103A is capable of sinking 60A at 1V output, and wellsuited for testing the new 3.3V low voltage power supplies. Low voltage
operation, down to zero volt, is possible at correspondingly reduced current
level.
The 6310A load module uses photo coupler for isolation between
the output and control sections, thus each load is isolated and
floating. The user can use multiple load modules independently
to test multi-output power supplies, or parallel them in high power
testing application.
Model 63103A Input Characteristics
80V
70V
The 6310A provides parallel controls, enabling high power testing
when a single module can not meet the requirements for high
power applications, two or more load modules can be paralleled
together to achieve the desired loading. The 6310A comes with
RS-232C as standard for remote control and automated testing
applications, with USB and GPIB interfaces as optional items.
In addition, the 6310A through its synchronized controls provides
an efficient solution for testing single output AC to DC or DC to DC
converters by controlling multiple loads, testing upto 8 UUTs at a
time.
60V
Voltage
Parallel Control
50V
40V
30V
20V
10V
0
3.75A
10A
20A
30A
40A
50A
60A Ampere
Low Voltage Characteristics (Typical)
Model 63101A/63102A/63103A/63106A/63112A
240A
63112A
220A
200A
180A
160A
140A
120A
Powerful Measurements
Each 6310A load module has integrated a 15-bit precision A/D
converter for voltage measurement with an accuracy of 0.05%
+0.05% full scale. The built-in resistive load current sensing circuit
is capable of measuring current in an accuracy of 0.1%+0.1% full
scale. Also, short circuit can be simulated.All measurement is done
using remote sensing to eliminate any error due to voltage drop
along the measurement path.The user can also select a full setting
range of voltage and current measurement according to application
requirements.
63106A
100A
OCP Test
80A
60A
63103A
40A
63101A
20A
63102A
0
0.2V
0.4V
0.6V
0.8V
1.0V
1.2V
Note: All specifications are measured at load input terminals. (Ambient Temperature of +25°C)
Dynamic Loading and Control
Modern electronic devices operate at very high speed, and perform
well in the transient and dynamic response of power devices. To
satisfy these testing applications, the 6310A loads offer high speed,
programmable dynamic load simulation and control capability
never achieved before. The figure below shows the programmable
parameters of the 6310A modules:
Modern switching power supplies are designed with over current
protection (OCP) circuitry. Therefore it is important to test the
OCP circuitry to make sure it is functioning within its designed
specifications. The 6310A series provides an easy and fast solution
for OCP testing.
By choosing the channel and setting the OCP parameters (start
current, end current, step current and dwell time) from the front
panel, the 6310A series provides a complete OCP testing solution.
The 6310A series will automatically detect the OCP point, making it
an ideal solution for design verification as well as in the production
line.
Amplitude
Load 1
rise rate
fall rate
V
UUT Output Voltage
Load 2
T1
T2
The programmable slew rate makes the simulation of transient
load change demanded by the requirement of real life application
possible. The 6310A internal waveform generator is capable of
producing maximum slew rate at 10A/us, and dynamic cycling up
to 20kHz. Its dedicated remote load senses and controls circuit to
guarantee minimum waveform distortion during continuous load
changes.
I
Loading Current
▃ Start
Current
▃ Dwell
Time
▃ Step
Current
▃ End
Time
Current
Timing Function
The 6310A series loads include a unique timing & measurement function allowing precise
time measurements in the range of 60ms to 100,000s. This feature allows the users to set
the final voltage & timeout values for battery discharge testing and other similar applications.
Final Voltage
Battery Voltage
For example, the right figure shows that the 6310A's internal timer can be initiated
automatically when the battery voltage falls below a preset value. The timer will continue
counting until the second preset value is reached.
The Timing function can be used in testing battery and super capacitor discharge, fuse and
breaker protection, rise time for ATX or D/D power supplies, and other similar applications.
Loading Current
Time
Battery Discharge Testing
Digital I/O
Digital I/O interface makes the 6310A DC
Load ideal choice for automated testing
requirements. Through the digital I/O, 6310A
can accept digital signals to trigger its functions
(Load On/Off, OCP test, etc.) as well as output
current status signals.
Pin
Definition
Pin 1
Reserved
Pin 9
Short Signal (O/P)
Pin 2
DGND
Pin 10
Protection Signal (O/P)
Pin 3
DGND
Pin 11
External Load ON/OFF (I/P)
Pin 4
DGND
Pin 12
Reserved
Pin 5
DGND
Pin 13
OCP Trig. Run (I/P)
Pin 6
Load ON/OFF (O/P)
Pin 14
DGND
Pin 7
Total Pass (O/P)
Pin 8
Total Fail (O/P)
Pin 15
External Trig. For
Sequences Run (I/P)
PANEL DESCRIPTION
Load Module
1
Mainframe Controller
8
9
2
3
4
11
12
10
13
14
16
15
17
18
5
6
20
24
25
7
19
26
21
22
23
Rear Panel
27
28
29
30
31
32
33
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
LED indicator
SHORT key : To apply a short circuit across the input
STATIC/DYNA key : To select static or dynamic test mode
L/R key : To select left or right channel of input load(63102A, 63107A)
A/B key : To select static A or B load (other models)
V terminal : To measure the UUT's output voltage using remote sense
Rotary knob : To adjust load setting continuously
Load terminal
LCD display
LED indicator : To display the channel at which load is set
CHAN key : To select input load channel
MODE key : To select the operation mode of CC, CR, CV, or CP
PROG key : For program data setting
OCP/OPP key : Over current protection/Over power protection testing
RECALL key : To recall the front panel input status from memory
SAVE key : To save the front panel input status into memory
SPEC key : To set up High/Low limits for GO/NG test
CONF key : To set the configuration
18 ON/OFF key : To enable or disable the load input
19 Up/Down key : To select the next or previous display
in edit mode
20 Numeric key : For data setting
21 ENTER key : To confirm editing data on the instrument
22 SHIFT key : As LOCAL Key when in remote mode
23 Power switch
24 SHIFT + 0 key : System function
25 SHIFT + . key : Lock function
26 SHIFT + 3 key : Clear the currently edited data
27 Digital I/O : Used for system input/output control signals
28 RS-232C connector
29 GO/NG output port
30 GPIB or USB slot
31 AC input voltage switch
32 AC input fuse
33 AC input connector
6310A Series Programmable DC Electronic Load Family
63112A
6314A : 4 in 1 Mainframe
63106A / 63108A
63102A
6312A : 2 in 1 Mainframe
63107A
63101A
63103A
A631001: Remote Controller
63105A
A630002 : GPIB Interface
A631003 : USB Interface
A MULTIPLE SELECTION FOR MULTIPLE OUTPUT SMPS TEST APPLICATION
Modern switching power supplies get more
complicated with more outputs and control signals
for PC or system requirements. Such as ATX power
supply needs more channels in a load to simulate or
test the output than the traditional AT power supply.
No doubt, you really need a new solution for your test
application! Chroma offers a broad selection of load
modules and at most an 8-channel load in a standard
mainframe. It is fit for any kinds of power supplies that
require different Power, Current or Voltage, and also
for testing the multiple output switching power supply.
63102A
63107A
63103A
Product Lineup
63103A
Model
Power
Operation Voltage
Current
63101A
200W
0~80V
40A
63103A
300W
0~80V
60A
63106A
600W
0~80V
120A
63112A
1200W
0~80V
240A
63102A
100W x 2
0~80V
20A(Dual Channels)
63107A
250W & 30W
0~80V
40A & 5A(Dual Channels)
63105A
300W
0~500V
10A
63108A
600W
0~500V
20A
6314A
+5V
-12V
-5V
+5VSB
Charger
+12V
+3.3V
A
more efficient solution to testing the single output AC to DC or DC
to DC converters by synchronization control with multiple loads
for testing 8 UUTs at one time.
Adapter
Battery
63102Ax4
Testing 8 Units at one time
SPECIFICATIONS
Resolution
Accuracy
Constant Voltage Mode
Range
Resolution
Accuracy
Constant Power Mode
Range
Resolution
Accuracy
Dynamic Mode
Dynamic Mode
T1 & T2
Accuracy
Slew Rate
Resolution
Min. Rise Time
Current
Resolution
Current Accuracy
Measurement Section
Voltage Read Back
Range
Resolution
Accuracy
Current Read Back
Range
Resolution
Accuracy
Current Accuracy
Protective Section
Over Power Protection
Over Current Protection
Over Temperature
Protection
Over Voltage Protection
General
Short Circuit
Current (CC)
Voltage (CV)
Resistance (CR)
Power (CP)
Input Resistance
(Load Off)
Temperature Coefficient
Power
Dimensions (WxHxD)
Weight
Operating Range
EMC & Safety
Mainframe Model
Dimensions(WxHxD)
Weight
0~4A
1mA
0.1%+0.1%F.S.
[email protected]
[email protected]
0~40A
10mA
0.1%+0.2%F.S.
0~2A
0.5mA
0.1%+0.1%F.S.
0~20A
5mA
0.1%+0.2%F.S.
63103A
30W
0~6A
[email protected]
[email protected]
30W
0~1A
[email protected]
[email protected]
[email protected]
[email protected]
0~60A
15mA
0.1%+0.2%F.S.
0~1A
0.25mA
0.1%+0.1%F.S.
0~80V
0~6A
1.5mA
0.1%+0.1%F.S.
63105A
300W
0~60A
0~500V
300W
0~10A
[email protected]
[email protected]
0~10A
2.5mA
0.1%+0.2%F.S.
0.0375Ω~150Ω (200W/16V)
1.875Ω~7.5kΩ (200W/80V)
12 bits
150Ω: 0.1 + 0.2%
7.5kΩ: 0.01 + 0.1%
0.075Ω~300Ω (100W/16V)
3.75Ω~15kΩ (100W/80V)
12 bits
300Ω: 0.1 + 0.2%
15kΩ: 0.01 + 0.1%
0.025Ω~100Ω (300W/16V)
1.25Ω~5kΩ (300W/80V)
12 bits
100Ω: 0.1 + 0.2%
5kΩ: 0.01 + 0.1%
1.25Ω~5Ω (300W/125V)
50Ω~200kΩ (300W/500V)
12 bits
5kΩ: 20m + 0.2%
200kΩ:5m + 0.1%
1~80V
20mV
0.05% ± 0.1%F.S.
1~80V
20mV
0.05% ± 0.1%F.S.
1~80V
20mV
0.05% ± 0.1%F.S.
2.5~500V
125mV
0.05% ± 0.1%F.S.
0~20W
0~200W
5mW
50mW
0.5% ± 0.5%F.S.
0~20W
0~100W
5mW
25mW
0.5% ± 0.5%F.S.
0~30W
0~300W
7.5mW
75mW
0.5% ± 0.5%F.S.
0~30W
0~300W
7.5mW
75mW
0.5% ± 0.5%F.S.
C.C. Mode
0.025ms ~ 50ms / Res: 5us
0.1ms ~ 500ms / Res: 25us
10ms ~ 50s / Res: 2.5ms
1µs/1ms+100ppm
0.64~160mA/µs
6.4~1600mA/µs
0.64mA/µs
6.4mA/µs
10µs (Typical)
0~4A
0~40A
1mA
10mA
0.4%F.S.
C.C. Mode
0.025ms ~ 50ms / Res: 5us
0.1ms ~ 500ms / Res: 25us
10ms ~ 50s / Res: 2.5ms
1µs/1mS+100ppm
0.32~80mA/µs
3.2~800mA/µs
0.32mA/µs
3.2mA/µs
10µs (Typical)
0~2A
0~20A
0.5mA
5mA
0.4%F.S.
C.C. Mode
0.025ms ~ 50ms / Res: 5us
0.1ms ~ 500ms / Res: 25us
10ms ~ 50s / Res: 2.5ms
1µs/1ms+100ppm
0.001~0.25A/µs
0.01~2.5A/µs
0.001A/µs
0.01A/µs
10µs (Typical)
0~6A
0~60A
1.5mA
15mA
0.4%F.S.
C.C. Mode
0.025ms ~ 50ms / Res: 5us
0.1ms ~ 500ms / Res: 25us
10ms ~ 50s / Res: 2.5ms
1µs/1ms+100ppm
0.16~40mA/µs
1.6~400mA/µs
0.16mA/µs
1.6mA/µs
24µs (Typical)
0~1A
0~10A
0.25mA
2.5mA
0.4%F.S.
0~16V
0~80V
0.5mV
2.5mV
0.05% + 0.05%F.S.
0~16V
0~80V
0.5mV
2.5mV
0.05% + 0.05%F.S.
0~16V
0~80V
0.5mV
2.5mV
0.05% + 0.05%F.S.
0~125V
0~500V
4mV
16mV
0.05% + 0.05%F.S.
0~4A
0~40A
0.125mA
1.25mA
1mA
10mA
0.1% + 0.1%F.S.
0~2A
0~20A
0.0625mA
0.625mA
0.5mA
5mA
0.1% + 0.1%F.S.
0~6A
0~60A
0.1875mA
1.875mA
1.5mA
15mA
0.1% + 0.1%F.S.
0~1A
0~10A
0.032mA
0.320mA
0.25mA
2.5mA
0.1% + 0.1%F.S.
Ω
Ω
Range
0~80V
63102A (100Wx2)
20W
100W
0~2A
0~20A
0~80V
[email protected]
[email protected]
[email protected]
[email protected]
≒20.8W
≒4.08A
≒208W
≒40.8A
Ω
Ω
Constant Current Mode
Range
Resolution
Accuracy
Constant Resistance Mode
[email protected]
[email protected]
200W
0~40A
≒20.8W
≒2.04A
≒104W
≒20.4A
Ω
Ω
Min. Operation Voltage (DC)*1
(Typical)
63101A
20W
0~4A
≒31.2W
≒6.12A
≒312W
≒61.2A
Ω
Ω
Model
Power
Current
Voltage
≒31.2W
≒1.02A
≒312W
≒10.2A
≒85°C
≒85°C
≒85°C
≒85°C
≒81.6V
≒81.6V
≒81.6V
≒510V
-
-
≒40A
0V
≒0.0375Ω
≒200W
≒20A
0V
≒0.075Ω
≒100W
-
-
≒60A
0V
≒0.025Ω
≒300W
≒10A
0V
≒1.25Ω
≒300W
100kΩ (Typical)
100kΩ (Typical)
100kΩ (Typical)
100kΩ (Typical)
100PPM/°C (Typical)
Supply from 6314A Mainframe
81 x 172 x 495 mm
4.2 kg
100PPM/°C (Typical)
Supply from 6314A Mainframe
81 x 172 x 495 mm
4.2 kg
100PPM/°C (Typical)
Supply from 6314A Mainframe
81 x 172 x 495 mm
4.2 kg
100PPM/°C (Typical)
Supply from 6314A Mainframe
81 x 172 x 495 mm
4.2 kg
0~40°C
CE
6312A
275x177x543mm
15kg
0~40°C
CE
0~40°C
CE
0~40°C
CE
6314A
439x177x543mm
22kg
continued on next page...
Model
Power
Current
Voltage
Min. Operation Voltage (DC)*1
(Typical)
60W
0~12A
63106A
63107A (30W & 250W)
30W
250W
0~4A
0~40A
0~80V
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
600W
0~120A
30W
0~5A
0~80V
[email protected]
[email protected]
[email protected]
[email protected]
60W
0~2A
63108A
600W
0~20A
0~500V
[email protected]
[email protected]
[email protected]
[email protected]
120W
0~24A
63112A
1200W
0~240A
0~80V
[email protected]
[email protected]
[email protected]
[email protected]
Constant Current Mode
Range
0~12A
0~120A
0~5A
0~4A
0~40A
0~2A
0~20A
0~24A
0~240A
Resolution
3mA
30mA
1.25mA
1mA
10mA
0.5mA
5mA
6mA
60mA
Accuracy
0.1%+0.1%F.S. 0.1%+0.2%F.S. 0.1%+0.1%F.S. 0.1%+0.1%F.S. 0.1%+0.2%F.S. 0.1%+0.1%F.S. 0.1%+0.2%F.S. 0.1%+0.1%F.S. 0.1%+0.2%F.S.
Constant Resistance Mode
0.0375Ω~150Ω
12.5mΩ~ 50Ω (600W/16V)
0.3Ω~1.2kΩ (30W/16V)
(250W/16V)
0.625Ω~2.5kΩ (600W/125V)
6.25mΩ~25Ω (1200W/16V)
Range
0.625Ω~2.5kΩ (600W/80V)
15Ω~60kΩ (30W/80W)
1.875Ω~7.5kΩ
25Ω~100kΩ (600W/500V)
0.3125Ω~1.25kΩ (1200W/80V)
(250W/80V)
Resolution
12 bits
12 bits
12 bits
12 bits
12 bits
50Ω: 0.4 + 0.5%
1.2kΩ: 0.1 + 0.2%
150Ω: 0.1 + 0.2%
25kΩ: 50m + 0.2%
25Ω: 0.8 + 0.8%
Accuracy
2.5kΩ: 0.04 + 0.2%
60kΩ: 0.01 + 0.1%
7.5kΩ: 0.01 + 0.1%
100kΩ: 5m + 0.1%
1.25kΩ: 0.08 + 0.2%
Constant Voltage Mode
Range
1~80V
1~80V
2~500V
1~80V
Resolution
20mV
20mV
125mV
20mV
Accuracy
0.05% ± 0.1%F.S.
0.05% ± 0.1%F.S.
0.05% ± 0.1%F.S.
0.05% ± 0.1%F.S.
Constant Power Mode
Range
0~30W
0~30W
0~250W
0~60W
0~600W
0~60W
0~600W
0~120W
0~1200W
Resolution
7.5mW
7.5mW
62.5mW
15mW
150mW
15mW
150mW
30mW
300mW
Accuracy
0.5% ± 0.5%F.S.
0.5% ± 0.5%F.S.
0.5% ± 0.5%F.S.
0.5% ± 0.5%F.S.
Dynamic Mode
Dynamic Mode
C.C. Mode
C.C. Mode
C.C. Mode
C.C. Mode
0.025ms~10ms/Res:1µs
0.025ms~10ms/Res:1µs
0.025ms~10ms/Res:1µs
0.025ms~10ms/Res:1µs
T1 & T2
1ms~30s/Res:1ms
1ms~30s/Res:1ms
1ms~30s/Res:1ms
1ms~30s/Res:1ms
Accuracy
1µs/1ms+100ppm
1µs/1ms+100ppm
1µs/1ms+100ppm
1µs/1ms+100ppm
Slew Rate
0.002~0.5A/µs
0.02~5A/µs
0.8~200mA/µs 0.64~160mA/µs 64~1600mA/µs 0.32~80mA/µs 3.2~800mA/µs
0.004~1A/µs
0.04~10A/µs
Resolution
0.002A/µs
0.02A/µs
0.8mA/µs
0.64mA/µs
64mA/µs
0.32mA/µs
3.2mA/µs
0.004A/µs
0.04A/µs
Min. Rise Time
10µs (Typical)
10µs (Typical)
24µs (Typical)
10µs (Typical)
Current
0~12A
0~120A
0~5A
0~4A
0~40A
0~2A
0~20A
0~24A
0~240A
Resolution
3mA
30mA
1.25mA
1mA
10mA
0.5mA
5mA
6mA
60mA
Current Accuracy
0.4%F.S.
0.4%F.S.
0.4%F.S.
0.4%F.S.
Measurement Section
Voltage Read Back
Range
0~16V
0~80V
0~16V
0~80V
0~16V
0~80V
0~125V
0~500V
0~16V
0~80V
Resolution
0.5mV
2.5mV
0.5mV
2.5mV
0.5mV
2.5mV
4mV
16mV
0.5mV
2.5mV
Accuracy
0.05% + 0.05%F.S.
0.05% + 0.05%F.S.
0.05% + 0.05%F.S.
0.05% + 0.05%F.S.
Current Read Back
Range
0~12A
0~120A
0~5A
0~4A
0~40A
0~2A
0~20A
0~24A
0~240A
Resolution
0.375mA
3.75mA
0.15625mA
0.125mA
1.25mA
0.375mA
0.625mA
0.75mA
7.5mA
Accuracy
3mA
30mA
1.25mA
1mA
10mA
0.5mA
5mA
6mA
60mA
Current Accuracy
0.1% + 0.1%F.S.
0.1% + 0.1%F.S.
0.1% + 0.1%F.S.
0.15% + 0.15%F.S.
Protective Section
Over Power Protection
≒62.4W
≒624W
≒31.2W
≒31.2W
≒260W
≒62.4W
≒624W
≒124.8W
≒1248W
Over Current Protection
≒12.24A
≒122.4A
≒5.1A
≒4.08A
≒40.8A
≒2.04A
≒20.4A
≒24.48A
≒244.8A
Over Temperature
≒85°C
≒85°C
≒85°C
≒85°C
Protection
Over Voltage Protection
≒81.6V
≒81.6V
≒510V
≒81.6V
General
Short Circuit
Current (CC)
≒120A
≒40A
≒20A
≒240A
Voltage (CV)
0V
0V
0V
0V
Resistance (CR)
≒0.0125Ω
≒0.0375Ω
≒0.625Ω
≒0.00625Ω
Power (CP)
≒600W
≒250W
≒600W
≒1200W
Input Resistance(Load Off)
100kΩ (Typical)
100kΩ (Typical)
100kΩ (Typical)
100kΩ (Typical)
Temperature Coefficient
100PPM/°C (Typical)
100PPM/°C (Typical)
100PPM/°C (Typical)
100PPM/°C (Typical)
Power
Supply from 6314A Mainframe
Supply from 6314A Mainframe
Supply from 6314A Mainframe
Supply from 6314A Mainframe
Dimensions (WxHxD)
162 x 172 x 495 mm
81 x 172 x 495 mm
162 x 172 x 495 mm
324 x 172 x 495 mm
Weight
8.4 kg
4.5 kg
8.4 kg
16.8 kg
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
0~40°C
CE
Ω
0~40°C
CE
0~40°C
CE
NOTE*1 :
Low voltage operation, under 0.8 volt, is possible at correspondingly reduced current level.
Operating temperature range is 0ºC to 40ºC. All specifications apply for 25ºC±5ºC, except as noted.
Ω
Operating Range
EMC & Safety
0~40°C
CE
All specifications are subject to change without notice.
ORDERING INFORMATION
6312A : Mainframe for 2 Load Modules
6314A : Mainframe for 4 Load Modules
63101A : Load Module 40A/80V/200W
63102A : Load Module 20A/80V/100Wx2 channels
63103A : Load Module 60A/80V/300W
63105A : Load Module 10A/500V/300W
63106A : Load Module 120A/80V/600W
63107A : Load Module 5A&40A/80V/30W&250W
63108A : Load Module 20A/500V/600W
63112A : Load Module 240A/80V/1200W
A630002 : GPIB Interface for Model 6314A, 6312A
A631003 : USB Interface for Model 6314A, 6312A
A631001 : Remote Controller
A631002 : Test Fixture
A631004 : Softpanel
Developed and Manufactured by :
Distributed by:
CHROMA ATE INC.
致茂電子股份有限公司
HEADQUARTERS
66, Hwa-Ya 1st Rd., Hwa-Ya
Technology Park, Kuei-Shan Hsiang,
Taoyuan Hsien 33383, Taiwan
Tel: +886-3-327-9999
Fax: +886-3-327-8898
http://www.chromaate.com
E-mail: [email protected]
U.S.A.
CHROMA ATE INC. (U.S.A.)
7 Chrysler Irvine, CA 92618
Tel: +1-949-421-0355
Fax: +1-949-421-0353
Toll Free: +1-800-478-2026
EUROPE
CHROMA ATE EUROPE B.V.
Morsestraat 32
NL-6716 AH Ede
The Netherlands
Tel: +31-318-648282
Fax: +31-318-648288
CHINA
CHROMA ELECTRONICS
(SHENZHEN) CO., LTD.
8F, No.4, Nanyou Tian An
Industrial Estate, Shenzhen,
China PC: 518054
Tel: +86-755-2664-4598
Fax: +86-755-2641-9620
Worldwide Distribution and Service Network
6310A-200808-PDF
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement