null  null
eCATALOGUE
AUSTRALIA
WOR LD LEA D ER O F INNOVATIV E SOLUTIO NS IN FIRE DETECT I O N AN D AL ARM S YS T E MS
AUS / PAGE 1
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
AMPAC TECHNOLOGIES
Ampac Technologies is the largest independent and privately owned
manufacturer and supplier of fire detection and alarm systems in Australia.
Ampac specialises in the research & development, design, manufacturing,
marketing and distribution for a complete range of system solutions. We
supply systems for a vast variety of applications including commercial and
industrial buildings, mines, prisons, hospitals, hotels and multi-residential
complexes.
Ampac operates Australia-wide through a network of branch offices. These
offices provide sales and technical support for fire installation & EWIS
contractors as well as fire discipline and electrical consulting engineers.
We also work with building owners and maintenance engineers to make
recommendations for future planning or budgeting.
CONTROL PANELS ZoneSense DH4 Conventional ZoneSense PLUS Conventional NEW LoopSense Intelligent
FireFinder Conventional/Intelligent
EMERGENCY WARNING SYSTEMS
NEW
EV3000 Emergency Warning System Speakers 45
53
GRAPHICS
SYSTEM
58
SmartGraphicsHD 58
60
65
70
INTERFACES77
Ampac’s comprehensive range of products enables us to deliver complete
solutions for fire detection and alarm systems of any size for any customer.
Indeed, developing unparalleled customer partnerships drives our desire
to be ‘World leaders of Innovatiove Solutions in Fire Detection and Alarm
Systems’.
HOME
45
Orbis Conventional XP95 Intelligent Discovery Intelligent Ampac Technologies is ISO 9001 accredited locally and also holds overseas
approvals with LPCB & UL for other key global markets.
CONTACT AMPAC
3
6
17 28
DETECTORS60
Since its inception in 1974, Ampac has grown to become a thriving global
operation with a focus on quality and exceptional customer service and
support. Our passion for growing our business through the relationships
we have with our customers is one that energises us. It fuels our desire
to make better products, implement more efficient systems, grow our
network of operations and develop our people.
AUS / PAGE 2
3
Ampac I/O Devices Apollo I/O Devices
78
82
AUDIO VISUAL SIGNALLING
85
XP95/Discovery Sounders, Beacons & Sounder Beacons inc Bases Ampac Bells, Strobes & Remote Indicators Klaxon Sounder Beacon Electronic Sounders 86
91
98
99
ANCILLARIES101
Power Supplies Manual Call Points Occupant Warning Systems Amplified Sound Systems Electro-Magnetic Door Holders Document Cabinets Test Equipment Batteries CONTENTS
SEARCH
ZOOM
PRINT
102
104
109
111
115
116
118
EXIT
CONTROL PANELS
ZoneSense DH4
Conventional Control Panel
The ZoneSense DH4 Control Panel is a simple and low cost 4 zone panel. It is a local
alarm panel which means that it is not suitable to be directly connected to fire brigade
monitoring equipment. It is an ideal fire panel for any small residential applications
(not requiring brigade monitoring) or can also be used as a door holder control panel.
Each of the 4 zones can be connected up to 40 x high quality commercial grade
conventional fire detectors to deliver a high quality detection & alarm system. It is
possible to use the ZoneSense panel in ‘Mains only’ option mode which eliminates the
need to connect back up batteries. Both ABS and Metal versions are available.
•Dual Door Holder Outputs
•Mains Only Mode
•Low Quiescent Current
•Single PCB architecture
•Walk Test Facility
•Class Change Input
•Alert Input
•Up to 40 Conventional detectors per Zone
•Available in ABS (BX1) and Metal (BX10) cabinet versions
AUS / PAGE 3
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS ZONESENSE DH4 Conventional
ZoneSense DH4 – Metal Cabinet
AUS / PAGE 4
CONTACT AMPAC
ZoneSense DH4 – ABS Cabinet
HOME
Power Supply
Mains Supply voltage
Nom. Operating voltage
Power Supply Current
Quiescent Current
Operating Temperature
Relative Humidity
204 – 264 VAC @ 47 – 63Hz
27 VDC
1.6 A (max)
20 mA (without Door Holder)
-5° to +55° C (no icing)
25% - 75% (non condensing)
Zone Detection Circuit
No of Zones
Zone Monitoring
Zone Quiescent Current
No of Detectors/Circuits
End Of Line (EOL)
Max Cable Length
Four (4) x 2-wire system
Open and Short circuit
4mA, 10uF EOL
40 (max)
10uF EOL
3km (Based on cable resistive and capacitive values of 50Ω and 1uF respectively)
Outputs Available
Alarm Outputs (monitored)
Door Holder outputs (monitored)
Fire Output Relay (voltage free)
Fault Output Relay (voltage free)
Auxiliary DC Output
Open Collector, 250mA
(2 O/P’s available) 10KΩ EOL
Open Collector, 250mA
(2 O/P’s available) 10KΩ EOL
NO, C, NC
Contact rating: 1A @ 30VDC
NO, C, NC
Contact rating: 1A @ 30VDC
150mA @ 24VDC
Miscellaneous Features
Class Change Input
Alert Input
Battery Monitoring
Non-Latching, switched -ve
Non-Latching, switched -ve
4 Way DIP switch array (factory set to “OFF”)
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS ZONESENSE DH4 Conventional
Mechanical
Material
ABS/Blend High Impact
ABS Cabinet
Metal Cabinet
1.2mm Mild Steel
Finish
ABS Cabinet
ABS Light Grey
Metal Cabinet
Metal Oyster Matt Ripple
ABS (BX1) Cabinet
H 300mm x W 360mm x D 100mm
Metal Cabinet (BX10)
H 300mm x W 360mm x D 100mm
H 310mm x W 500mm x D 110mm
Packed
Weight Packed excluding batteries
ABS3kg
Metal5.2kg
ZoneSense DH4 – Metal Cabinet
ZoneSense DH4 – ABS Cabinet
ZoneSense DH4 ABS (BX1) excl Batteries
ZoneSense DH4 METAL (BX10) excl Batteries
Metal BX10 Surround
2250-4200
2250-4250
ENC3016-A
Note:
Gyprock fixing (toggle brackets) are available to flush fit any Ampac ABS enclosure into a wall cavity
Item No (4210-0002 & 4210-0003 )
AUS / PAGE 5
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS
ZoneSense PLUS
Conventional Control Panel
The Ampac ZoneSense PLUS Fire Alarm Control Panel is a versatile four or eight zone
conventional panel. The user friendly navigation system provides simple operation
during an emergency while also enabling complex cause and effect programming to be
undertaken.
A range of modular panel add-on kits allows the panel to be professionally tailored to
the requirements of each installation. This means small conventional panels can now be
used in a wider range of applications.
ZoneSense PLUS offers you complete control. The panel can be easily upgraded and
programmed on site. ZoneSense PLUS is approved to AS4428 and is available in ABS
(BX1) or metal cabinets (BX20) with either four (4) or eight (8) zone conventional
detection circuits.
•Available in 4 Zone or 8 Zone Panels
•Up to 40 Conventional detectors per zone
•RS485 port supports a range of Add-on modules
•Available in ABS (BX1) and Metal (BX20) cabinet versions
•Complies with AS4428
AUS / PAGE 6
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS ZONESENSE PLUS Conventional
ZoneSense PLUS – ABS and Metal
ZoneSense PLUS – ABS Cabinet
AUS / PAGE 7
CONTACT AMPAC
ZoneSense PLUS – Metal Cabinet
HOME
Power Supply
Mains Supply voltage
Nom. Operating voltage
Power Supply Current
Quiescent Current
204 – 264 VAC @ 47 – 63Hz
27 VDC
2 A (max)
40.5 mA (min)
Zone Detection Circuit
No of Zones
Zone Monitoring
Zone Quiescent Current
No of Detectors/Circuits
Eon Of Line Value (EOL)
Max Cable Length
Four (4) or Eight (8) x 2-wire system
Open and Short circuit
4mA, 10uF EOL
40 (max)
3K3Ω (default), 4K7Ω, 6K8Ω, 10KΩ and 10uF (Optional)
3km (Based on cable resistive and capacitive values of 50Ω and 1uF respectively)
Outputs
Comms Output
EXT Bell Output (monitored)
Warning Sys Output (monitored)
ACF Output (monitored)
ASE Output (monitored)
Reset/Buzzer
Fire Alarm Output Relay (voltage free)
Fault Output Relay (voltage free)
Auxiliary DC Output (monitored)
RS485 (4 and 8 zone only)
1A (max) 10KΩ EOL
1A (max) 10KΩ EOL
1A (max) 10KΩ EOL
1A (max) 10KΩ EOL
Output Open Collector, 40mA 15sec pulse
NO, C, NC. Contact rating: 1A @ 30VDC
NO, C, NC. Contact rating: 1A @ 30VDC
500mA @ 24VDC10KΩ EOL
Miscellaneous
MCP input
Fault input
Door Switch
Non-Latching, switched –ve
Non-Latching, switched –ve
Non-Latching, switched –ve
Environmental
Operating Temperature
Relative Humidity
-5° to +55° C (no icing)
25% - 75% (non condensing)
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS ZONESENSE PLUS Conventional
ZoneSense PLUS – ABS
Certain ABS versions also come optionally with the provision of extra window space. These windows
are to allow for space to add ZoneSense Plus Add on Modules into the panel fascia.
Mechanical
Material
Finish
Dimensions
Weight packed excluding Batteries
ZoneSense PLUS – ABS Cabinet
ZoneSense PLUS – ABS Cabinet
with Windows
ABS/Blend High Impact
ABS Light Grey
300mm (H) x 360mm (W) x 100mm (D)
3kg
ZoneSense PLUS Control Panel
4 Zone ABS (BX1)
8 Zone ABS (BX1)
4 Zone ABS (BX1) with windows
8 Zone ABS (BX1) with windows
ABS Joiner Moulding
Ancillary Cabinet ABS (BX1)
2550-1100
2550-1200
2550-2100
2550-2200
ENC1851-A
2510-9001
Note:
Gyprock fixing (toggle brackets) are available to flush fit any Ampac ABS enclosure into a wall cavity
Item No (4210-0002 & 4210-0003 )
ZoneSense PLUS – ABS Ancillary Cabinet
AUS / PAGE 8
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS ZONESENSE PLUS Conventional
ZoneSense PLUS – Metal
A diverse range of factory pre assembled ZoneSense Plus products are made available for the
installers convenience. These include a range with occupant warning system pre fitted and or Agent
Release (Gas) module fitted.
It is also possible to fit ZoneSense Plus “add on modules” after purchasing a standard ZoneSense Plus
panel as long as there is space provision on the enclosure to fit the module.
Mechanical
Material
Finish
Dimensions
Weight packed excluding Batteries
1.2mm Mild Steel
Metal Oyster Matt Ripple
ZoneSense Plus Metal: 500(H) x 405(W) x 145(D) mm
Metal Ancillary Cabinet: 250(H) x 405(W) x 145(D) mm
ZoneSense Plus Metal: 8.5kg
Metal Ancillary Cabinet: 2kg
ZoneSense PLUS Control Panel
4 Zone Metal (BX20) with MCP
8 Zone Metal (BX20) with MCP
4 Zone Metal (BX20) with Agent Release
8 Zone Metal (BX20) with Agent Release
4 Zone EV20 OWS Fitted
8 Zone EV20 OWS Fitted
4 Zone EV40 OWS Fitted
8 Zone EV40 OWS Fitted
Ancillary Cabinet Metal (BX20)
Surround for Metal Cabinet only
Surround for Metal & Ancillary Cabinet
ZoneSense PLUS – Metal Cabinet
2550-0100
2550-0200
2550-0151
2550-0252
2550-0120
2550-0220
2550-0140
2550-0240
8510-9001
ENC1798-A
ENC1797-A
ZoneSense PLUS – Rack Mount
For added flexibility ZoneSense Plus Rack versions are now available. This allows a ZoneSense Plus
Fire indicator panel to be easily integrated in a rack arrangement with other larger models of Ampac
warning systems
ZoneSense PLUS Control Panel
4 Zone Combo Rack Mount
8 Zone Combo Rack Mount
AUS / PAGE 9
CONTACT AMPAC
HOME
CONTENTS
SEARCH
2553-0400
2553-0800
ZOOM
PRINT
EXIT
CONTROL PANELS ZONESENSE PLUS Conventional – Add Ons
Input Board
•
•
•
•
•
Provides inputs for sprinkler pumps, tanks, valves, shutdowns, etc
16 inputs per board
Inputs map to relays or indicators
Programmed via the ZoneSense PLUS front panel
Max 1 per ZoneSense PLUS
Voltage
Quiescent current
Max current
Output rating
Operating temperature
Relative humidity
Weight
24 VDC
2.6 mA
45 mA
0.5 amp at 24 VDC
-5°C to +55°C (no icing)
0 to 95% (non condensing)
120 grams
Input Board
4310-0040
Relay Board
•
•
•
•
•
•
Provides volt free change over contacts
8 relay outputs per board
Programmed via the ZoneSense PLUS front panel
Max 1 per ZoneSense PLUS system
Remote version available – DIN Mount chassis
Remote version communication via RS485 serial link
Voltage
Quiescent current
Max current
Relay contact rating
Operating temperature
Relative humidity
Weight
24 VDC
2.4 mA
80 mA
1 amp at 24 VDC
-5°C to +55°C (no icing)
0 to 95% (non condensing)
130 grams
Relay Board
Relay Board (Remote)
AUS / PAGE 10
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
4310-0050
4310-0055
PRINT
EXIT
CONTROL PANELS ZONESENSE PLUS Conventional – Add Ons
Sounder Board
• Provides 8 monitored switched 24 VDC outputs per board
• Programmed via the ZoneSense PLUS front panel
• Max 1 per ZoneSense PLUS
Voltage
Quiescent current
Max current
Output rating (ea)
Operating temperature
Relative humidity
Weight
24 VDC
5.6 mA
26 mA
500 mA at 24 VDC
-5°C to +55°C (no icing)
0 to 95% (non condensing)
100 grams
Sounder Board
4310-0060
Fire Brigade Board
•Provides common outputs for connection to fire brigade signalling
equipment
• 5 outputs – Alarm, Fault, Isolate, Battery Fail and 2nd Alarm
• Programmed via the ZoneSense PLUS front panel
• Max 1 per ZoneSense PLUS
Voltage
Quiescent current
Max current
Output rating
Operating temperature
Relative humidity
Weight
24 VDC
9 mA
52 mA
1 amp at 24 VDC
-5°C to +55°C (no icing)
0 to 95% (non condensing)
110 grams
Fire Brigade Board
AUS / PAGE 11
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
4310-0070
PRINT
EXIT
CONTROL PANELS ZONESENSE PLUS Conventional – Add Ons
Fire Fan Module
•Controls and monitors fire fans, dampers, sprinkler pumps etc.
•4 controls per module
•Separate start and stop output per control
•3 status inputs per control
•Labels can be modified on site
•Programmed via the FACP front panel
•Max 1 per ZoneSense PLUS
•Location or title descriptor label
Voltage
Quiescent current
Max current
Relay contact rating
Operating temperature
Relative Humidity
Weight
24 VDC
13.5 mA
50 mA
3 amp at 24 VDC
-5°C to 55°C (no icing)
0 to 95% (non condensing)
230 grams
Fire Fan Module
4310-0021
Switch/Indicator Card
•Controls and monitors solenoid test switches, manual shutdowns etc
•Eight (8) push on / push off switches per card
•Switches map to relays – requires relay board (Order Code: 4310-0050)
•One (1) status indicator per switch – requires input board (Order Code:
4310-0040)
•Labels can be modified on site
•Programmed via the FACP front panel
•Max 1 per ZoneSense PLUS
•Location or title descriptor label
Voltage
Quiescent current
Max current
Operating temperature
Relative Humidity
Weight
24 VDC
3.6 mA
8 mA
-5°C to 55°C (no icing)
0 to 95% (non condensing)
100 grams
Switch/Indicator Card
AUS / PAGE 12
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
4310-0030
PRINT
EXIT
CONTROL PANELS ZONESENSE PLUS Conventional – Add Ons
Agent Release Module
•Compliance with AS4214
•Controls & Monitors Agent release system
•Outputs for warning signs & activation devices
•Inputs for signals from pressure switches & valves
•Serial connection to Agent release (LCS) Local control Station
•Programmed via the FACP front panel
•Maximum is 1 per ZoneSense PLUS
•Location or title descriptor label
24 VDC
28.5 mA
1.5 A
1 amp at 24 VDC
-5°C to 55°C (no icing)
0 to 95% (non condensing)
250 grams
Voltage
Quiescent current
Max current
Relay contact rating
Operating temperature
Relative Humidity
Weight
Agent Release Module
4310-0011
Agent Release – Local Control Station
•Remote Agent release LCS
•Complies with AS4214
•For Use only with Agent release Module 4310-0011
•Double Action manual Agent release facility
•Toggle between initial & reserve agent
•Can install up to 8 x LCSs per panel
Material
Finish
Dimension
Weight
Operating Voltage
Quiescent Current
Monitored Inputs
Manual Release
Stage 1 & 2
System Inoperative
Gas Fired
Comms Output
1.2mm steel for Back Box
Oyster matt ripple
233H x 186W x 47D mm
860 grams
27VDC
40.5mA
Pressure Switch; Low Pressure Switch; Interlock
2A @ 27VDC (Current Limited)
Switched 1A @ 27VDC
1A @ 27VDC
1A @ 27VDC
RS485
Local Control Station
AUS / PAGE 13
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
4310-0019
PRINT
EXIT
CONTROL PANELS
ZoneSense PLUS AR
Agent Release Panel
The ZoneSense PLUS AR (Agent Release) Panel is a dedicated panel for agent release
systems. Housed in a metal cabinet, the ZoneSense PLUS AR is available in either four
(4) or eight (8) zones. Based on a ZoneSense PLUS Fire Alarm Control Panel (FACP), the
AR version is fitted with an Agent Release Panel Add-on (control card and termination
board) and a dual action yellow manual call point as standard. The Agent Release panel
add-on option is factory set.
•Dedicated Agent Release system - purpose built with a host of ancillary products to
suit
•Comprehensive system status – the AR panel includes a number of system status
indicators that facilitates ease of operation and maintenance
•Local Control Station with control and indication – mimics full status of the Agent
Release panel. An outdoor version of this product is available
•User interface and operation based around Industry Fire Emergency procedures –
ensures that the system installed is intuitive and easy to use
•Dual action Manual Call Point – the yellow MCP is a break glass type and requires
a dual action to be activated i.e. lift the protective transparent cover and break the
glass
•Agent Release Panel is compliant with AS4214
AUS / PAGE 14
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS ZoneSense PLUS AR
Fire Alarm Control Panel
Operating Voltage
Quiescent Current
Power Supply
Ext Bell Output
Warning Sys Output
ACF Output
ASE Output
Fire Alarm Output
Fault Output
Aux DC Output
Reset/Buzzer
Communications Output
End-Of-Line Values
Material
Finish
Dimension
Weight (excluding batteries)
23 to 28 VDC
37 mA (minimum)
27VDC (nominal) @ 2Amps
1A (max) – monitored
1A (max) – monitored
1A (max) – monitored
1A (max) – monitored
Volt free 1A @ 24 VDC
Open Collector Output
Volt free 1A @ 24 VDC
Open Collector Output
500mA @ 24 VDC – monitored
Open Collector Output
RS485
3k3 (fitted as standard), 4k7, 6k8, or 10k ohms, 10μ Farad
1.2 mm mild steel
Oyster matt ripple
Metal Cabinet: 500H x 405W x 145D mm
Metal ancillary cabinet: 250H x 405W x 145D mm
8kg
Agent Release System
Pressure Switch Input
Monitored Input
Low Pressure Switch Input
Monitored Input
Monitored Input
Interlock Input
Volt Free Changeover
Gas Fired Output
[email protected]
Volt Free Changeover
System Inoperative Output
[email protected]
Stage 1 Output
Monitored
Stage 2 Output
Monitored
Release Initial Agent Output
Monitored current limited 2A max
Release Reserve Agent Output
Monitored current limited 2A max
ZoneSense PLUS AR
ZoneSense PLUS AR 4 Zone
ZoneSense PLUS AR 8 Zone
AUS / PAGE 15
CONTACT AMPAC
HOME
CONTENTS
SEARCH
2550-0151
2550-0252
ZOOM
PRINT
EXIT
CONTROL PANELS ZoneSense PLUS AR – Ancillary Products
Agent Release Warning Signs
IP50 Model
The AR panel supports a 2-wire connection to warning signs. The 2-wire
connection supports both single or dual stage signs. The latter is possible
because of the voltage reverse technology adopted by the AR panel.
Multiple warning signs may be connected to the AR panel. The connection
will be in a ‘daisy chain’ configuration with the last warning sign fitted with
an End-Of-Line (EOL) resistor. The EOL resistor facilitates the monitoring of
the warning sign circuit. A maximum of 6 warning signs may be fitted
to an AR panel.
An on-board buzzer fitted to every sign provides audible warning.
However in the event AS1670.4 audible warning tones are required,
external electronic sounders may be connected directly to each warning
sign. An external switch may be connected to the sign to mute audible
warning.
IP65 Model
AUS / PAGE 16
CONTACT AMPAC
HOME
CONTENTS
ACP-04 Manual Call Point Yellow
ACP-04 Manual Call Point Hinged Cover
213-0061
213-0057
IP50 SIGNS
Warning sign back box (IP50) no fascia207-0050
“Extinguishing System Inoperative” complete IP50
207-0051
Special wording fascia only
207-0052
“Fire Alarm, Do Not Enter” fascia only
207-0053
207-0054
“Fire Alarm, Evacuate Area” fascia only
“Do Not Enter, Gas Discharged” fascia only
207-0055
“Fire Door CLosing” fascia only
207-0056
“Do Not Enter” fascia only
207-0057
IP65 SIGNS
Warning sign back box (IP65) no fascia
207-0060
“Extinguishing System Inoperative” complete IP65
207-0061
Special wording fascia only
207-0062
“Fire Alarm, Do Not Enter” fascia only
207-0063
207-0064
“Fire Alarm, Evacuate Area” fascia only
207-0065
“Do Not Enter, Gas Discharged” fascia only
“Fire Door Closing” fascia only
207-0066
“Do Not Enter” fascia only
207-0067
SOUNDERS
Vantage Sounder (Red/White)
205-0062/63
Vantage Combi (Red/White)
205-0066/67
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS
NEW
LoopSense
Intelligent Control Panel
LoopSense is an Intelligent Analogue Addressable Fire Alarm Control Panel. Available
in one or two loops, the LoopSense comes packed with options and features that
facilitate flexibility, ease of installation and commissioning.
• Clear back-lit 240 x64 graphic LCD
• 500mA loop current
•Advanced balanced loop design for noise rejection
• Auto learn facility
• Supports extensive range of Add Ons, including the SmartTerminal Repeater
• User friendly Loopmaster programming software tool
• Laptop connection using USB2.0 or RS232 serial port
• Complies to AS7240-2:2004, AS7240-4:2004, and AS4428-3:2010 -ActivFire ® listed
AUS / PAGE 17
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS LOOPSENSE Intelligent
Power Supply (General)
Output Voltage Battery Type (maximum) Battery Discharged Cut Off Voltage
NEW LoopSense – SP1X Cabinet
AUS / PAGE 18
CONTACT AMPAC
NEW LoopSense – SP8X Cabinet
HOME
SP1XSP8X
27.5VDC +/- 0.1VDC
26Ah
21VDC
27.5VDC +/- 0.1VDC
40.0Ah
21VDC
Base Panel
Quiescent Current
1 Loop Panel
2 Loop Panel
115mA
135mA
115mA
135mA
Loop
Loop current Detectors/Devices per Loop
Cabling Requirements Fault supervision Protocol 500mA max
126 max
2 core 1.5 to 2.5mm
O/C, S/C, overcurrent
XP95, Discovery
500mA max
126 max
2 core 1.5 to 2.5mm
O/C, S/C, overcurrent
XP95, Discovery
Outputs
Alarm Sounder Outputs Relay outputs
Open Collector Output
Auxiliary VDC
4 x supervised/programmable
24VDC @ 500mA max
3 x programmable
Voltage free 24VDC @ 1A
2 x programmable – 30mA
2 x protected/programmable
24VDC @ 500mA
4 x supervised/programmable
24VDC @ 500mA max
3 x programmable
Voltage free 24VDC @ 1A
2 x programmable – 30mA
2 x protected/programmable
24VDC @ 500mA
Inputs
Supervised
4 x O/C, S/C, 10K EOL
4 x O/C, S/C, 10K EOL
Communications Port
Internal to LoopSense External to LoopSense Printer port PC Interfacing RS485
RS485
RS232 or Parallel
RS232 or USB 2.0
RS485
RS485
RS232 or Parallel
RS232 or USB 2.0
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS LOOPSENSE Intelligent
Electrical
Power Supply
Input Voltage Protection Output Current
Charger Current NEW LoopSense – SP1X Cabinet
NEW LoopSense –SP8X Cabinet
SP1XSP8X
3A PSU version
204 - 264VAC 3Amp M205 3Amps
600mA 6A PSU version
204 - 264VAC
5Amp M205
4Amps
1000mA
Environmental
Operating temperature
Relative humidity
IP rating
-5°C to +55°C (no icing)
-5°C to +55°C (no icing)
25% to 75% (non condensing) 25% to 75% (non condensing)
IP30
IP30
Mechanical
Material
Finish Dimensions Weight 1.2mm steel
Surf Mist Ripple 505H x 405W x 150Dmm 9kg 1.2mm steel
Surf Mist Ripple
845H x 515W x 175Dmm
15kg
NEW LoopSense Intelligent Control Panel
LoopSense, 1 Loop. 3A SP1X Enclose
LoopSense, 2 Loop. 3A SP1X Enclosure
LoopSense, 1 Loop. 6A SP8X Enclosure
LoopSense, 2 Loop. 6A SP8X Enclosure
8251-0110
8251-0210
8251-0113
8251-0213
Flush Mount Surround for SP1X
Flush Mount Surround for SP8X
2nd Loop Activation Key 4210-0042
4210-0044
8210-0001
*Approvals: AS7240-2:2004, AS7240-4:2004, AS4428-3:2010
AUS / PAGE 19
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS LOOPSENSE Intelligent
Dot Matrix Panel Printer
•The dot matrix printer provides hardcopy activity report
•Alarms, faults, isolates and system logs may be printed
•3 colour status LED
•Self test mode
•Easy maintenance for replaceable ribbon cassette and paper roll
Voltage
Quiescent current
Character size
Operating temperature
Relative humidity
Weight
5 VDC
1A @ 5 VDC
5 x 7 dots
-5°C to +55°C (no icing)
25 to 95% (non condensing)
380 grams
Dot Matrix Panel Printer
159-0110
MIS1981
Paper – 10 rolls
RibbonMIS1982
SmartTerminal Repeater
The SmartTerminal Repeater is an LCD annunciator designed to remotely
display the status and provide control of the LoopSense Fire Alarm
Control Panel.
•Connects to a Communication Driver Board inside the LoopSense
Control Panel
•4 line by 40 character LCD with backlight and navigation keys UP/
DOWN keys allow the SmartTerminal to be used for FACP operation
and interrogation
•Buzzer and system Reset
•Flush or surface mountable enclosure
•Controls have tactile and audible feedback of operation
•All terminals cater for 2.5mm cables
•Stand alone power supply capabilities
•Flush mount kit available (Gyprock toggel fixings)
•Max 30 Per LoopSense
AUS / PAGE 20
CONTACT AMPAC
HOME
CONTENTS
Voltage
Quiescent current (backlight/buzzer off )
Max current (backlight/buzzer on)
Max distance from main panel
Auxiliary output (monitored)
Operating temperature
Relative humidity
SmartTerminal Repeater
Size
SmartTerminal Slimline Repeater
Weight SmartTerminal Repeater
SmartTerminal Slimline Repeater
24 VDC
12.4 mA
44 mA
1.2 km
27 VDC 500 mA
-5°C to +55°C (no icing)
25 to 95% (non condensing)
300H x 360W x 100Dmm
195H x 324W x 52Dmm
2.5 kg
1 kg
NEW LoopSense SmartTerminal Repeaters
SmartTerminal wthout PSU
SmartTerminal Repeater with 2 Amp PSU
SmartTerminal Slim Line Repeater without PSU
4350-0004
4350-0005
4350-0006
Mounting Kit (Flush Mount)
4210-0002
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS LOOPSENSE Intelligent- Add Ons
Relay Board
•
•
•
•
Voltage
24 VDC
Quiescent current
2.4 mA
80 mA
Max current
Relay contact rating
1 amp at 24 VDC
Operating temperature
-5°C to +55°C (no icing)
Relative humidity
0 to 95% (non condensing)
Weight
130 grams
System Capacity:
LoopSense
15 Maximum
ZoneSense Plus
1 Maximum
Provides volt free change over contacts
8 relay outputs per board
Remote version available – DIN Mount chassis
Remote version communication via RS485 serial link
Relay Board
Relay Board (Remote)
4310-0050
4310-0055
Sounder Board
• Provides 8 monitored switched 24 VDC outputs per board
Voltage
24 VDC
Quiescent current
5.6 mA
500 mA at 24 VDC
Output rating (ea)
Operating temperature
-5°C to +55°C (no icing)
0 to 95% (non condensing)
Relative humidity
Weight
100 grams
System Capacity:
LoopSense
15 Maximum
ZoneSense Plus
1 Maximum
Sounder Board
AUS / PAGE 21
CONTACT AMPAC
HOME
CONTENTS
SEARCH
4310-0060
ZOOM
PRINT
EXIT
CONTROL PANELS LOOPSENSE Intelligent- Add Ons
Fire Brigade Board
•Provides common outputs for connection to fire brigade signalling
equipment
• 5 outputs – Alarm, Fault, Isolate, Battery Fail and 2nd Alarm
Voltage
24 VDC
Quiescent current
9 mA
Max current
52 mA
Output rating
1 amp at 24 VDC
Operating temperature
-5°C to +55°C (no icing)
Relative humidity
0 to 95% (non condensing)
Weight
110 grams
System Capacity:
LoopSense
1 Maximum
ZoneSense Plus
1 Maximum
Fire Brigade Board
4310-0070
Input Board
•
•
•
•
Provides inputs for sprinkler pumps, tanks, valves, shutdowns, etc
16 inputs per board
Inputs map to relays or indicators
Programmed via the LoopMaster
Voltage
24 VDC
Quiescent current
2.6 mA
45 mA
Max current
Output rating
0.5 amp at 24 VDC
-5°C to +55°C (no icing)
Operating temperature
Relative humidity
0 to 95% (non condensing)
Weight
120 grams
System Capacity
LoopSense
15 Maximum
ZoneSense Plus
1 Maximum
Input Board
AUS / PAGE 22
CONTACT AMPAC
HOME
CONTENTS
SEARCH
4310-0040
ZOOM
PRINT
EXIT
CONTROL PANELS LOOPSENSE Intelligent- Add Ons
NEW
8 Zone Conventional Board
•Supports up to eight conventional zones
•Selectable end of line device 3K3, 4K7, 6K8, 10K or 10µF capacitor
•Supports head removal requirement on each zone
•Supports up to 40 conventional devices per zone circuit (ORBIS)
•Programmable latching and non-latching (self-resetting) input on
each zone circuit
Voltage
24 VDC
Quiescent current
15mA (including capacitive EOL
current) plus device current
Alarm current
43mA (one circuit in alarm)
Operating temperature
-5°C to +55°C (no icing)
Relative humidity
0 to 95% (non condensing)
Size
72.5 x 155mm
Weight
120 grams
System Capacity:
LoopSense
15 Maximum
8 Zone Conventional Board
4310-0082
NEW
32 Zone Indicator Card
•
•
•
•
•
Provides 32 Zone LED’s capable of indicating zone Fire, Disabled, Fault and Dependency B.
Suitable for use with the FireFinder range of FACP’s
Suitable for use with LoopSense FACP
Customisable zone identification label
Fully programmable via LoopMaster
Voltage
27 VDC
Quiescent current
3.6 mA
Max current
8mA
Output rating
0.5 amp at 24 VDC
Operating temperature
-5°C to +55°C (no icing)
Relative humidity
0 to 95% (non condensing)
Weight
100 grams
System Capacity:
LoopSense
15 Maximum
32 Zone Indicator Card
Slip In Label
AUS / PAGE 23
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
4310-0086
LAB 3001
PRINT
EXIT
CONTROL PANELS LOOPSENSE Intelligent- Add Ons
Switch/Indicator Card
•8 x Push Button On / Off switches
•8 x LED display of the On / Off condition
•Controls and Monitors solenoid test switches, manual shutdowns and
etc
•Programmable via the ZoneSense PLUS front panel
•Programmable via ConfigManager for the FireFinder range of panels
•Programmable via LoopMaster for the LoopSense range of panels
Voltage
24 VDC
Quiescent current
3.6 mA
Max current
8 mA
Operating temperature
-5°C to 55°C (no icing)
Relative Humidity
0 to 95% (non condensing)
Weight
100 grams
System Capacity:
FireFinder
15 Maximum
LoopSense
15 Maximum
ZoneSense Plus
1 Maximum
Switch/Indicator Card
Slip in Label
AUS / PAGE 24
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
4310-0030
LAB 1483
PRINT
EXIT
CONTROL PANELS LOOPSENSE Intelligent- Add Ons
Fire Fan Module
Each Fire Fan Module houses the control and indication of up to four (4)
fire fans and a single control/indication for plant trip reset.
A hard-wired version of a fire fan module consists of a Fire Fan Control
Card and Termination Board. Field wiring is terminated to the termination
board at the FACP.
A loop-driven version is also available and in this configuration only the
Fire Fan Control Card would be required. Field wiring will terminate to
address input/output devices that operate on the addressable loop.
•Four (4) Controls per Module
•Status indication for Run / Fault / Stop
•Controls for ON / Auto / Off
•Audible and visual feedback of button press
•Built in Plant Trip Reset
•Supports 3, 4 and 5 Wire Connections
•Available in Hardware or loop driven versions
•Communicates with FACP via RS485 communication port
•Where applicable all terminals cater for 2.5mm² cables
AUS / PAGE 25
CONTACT AMPAC
HOME
CONTENTS
Operating Voltage
27VDC
Dimensions:
Fits standard Panel Cut-Out
Controller Card
Termination Board
155mm x 72mm
Contact Rating
1 amp @ 24VDC
ApprovalAS1668
System Capacity:
15 Maximum
FireFinder
LoopSense
15 Maximum
ZoneSense Plus
1 Maximum
Hard Wired
Loop Driven
Slip in Label Template
SEARCH
ZOOM
4310-0021
4310-0071
LAB1486
PRINT
EXIT
CONTROL PANELS LOOPSENSE Intelligent- Add Ons
Agent Release Module
•Compliance with AS4214
•Controls & Monitors Agent release system
•Outputs for warning signs & activation devices
•Inputs for signals from pressure switches & valves
•Serial connection to Agent release (LCS) Local control Station
•Programmed via the FACP front panel
•Maximum is 1 per FACP
•Location or title descriptor label
Voltage
Quiescent current
Max current
Relay contact rating
Operating temperature
Relative Humidity
Weight
24 VDC
28.5 mA
1.5 A
1 amp at 24 VDC
-5°C to 55°C (no icing)
0 to 95% (non condensing)
250 grams
System Capacity
FireFinder
8 Max
LoopSense
8 Max
1 Max
ZoneSense PLUS
Agent Release Module
4310-0011
Agent Release – Local Control Station
•Remote Agent release LCS
•Complies with AS4214
•For Use only with Agent release Module 4310-0011
•Double Action manual Agent release facility
•Toggle between initial & reserve agent
•Can install up to 8 x LCSs per panel
Material
Finish
Dimension
Weight
Operating Voltage
Quiescent Current
Monitored Inputs
Manual Release
Stage 1 & 2
System Inoperative
Gas Fired
Comms Output
1.2mm steel for Back Box
Oyster matt ripple
233H x 186W x 47D mm
860 grams
27VDC
40.5mA
Pressure Switch; Low Pressure Switch; Interlock
2A @ 27VDC (Current Limited)
Switched 1A @ 27VDC
1A @ 27VDC
1A @ 27VDC
RS485
Local Control Station
AUS / PAGE 26
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
4310-0019
PRINT
EXIT
CONTROL PANELS LoopSense Intelligent – Ancillary Products
Agent Release Warning Signs
The AR panel supports a 2-wire connection to warning signs. The 2-wire
connection supports both single or dual stage signs. The latter is possible
because of the voltage reverse technology adopted by the AR panel.
Multiple warning signs may be connected to the AR panel. The connection
will be in a ‘daisy chain’ configuration with the last warning sign fitted with
an End-Of-Line (EOL) resistor. The EOL resistor facilitates the monitoring of
the warning sign circuit. A maximum of 6 warning signs may be fitted
to an AR panel.
An on-board buzzer fitted to every sign provides audible warning.
However in the event AS1670.4 audible warning tones are required,
external electronic sounders may be connected directly to each warning
sign. An external switch may be connected to the sign to mute audible
warning.
AUS / PAGE 27
CONTACT AMPAC
HOME
CONTENTS
ACP-04 Manual Call Point Yellow
ACP-04 Manual Call Point Hinged Cover
213-0061
213-0057
IP50 SIGNS
Warning sign back box (IP50) no fascia207-0050
“Extinguishing System Inoperative” complete IP50
207-0051
Special wording fascia only
207-0052
“Fire Alarm, Do Not Enter” fascia only
207-0053
207-0054
“Fire Alarm, Evacuate Area” fascia only
“Do Not Enter, Gas Discharged” fascia only
207-0055
“Fire Door CLosing” fascia only
207-0056
“Do Not Enter” fascia only
207-0057
IP65 SIGNS
Warning sign back box (IP65) no fascia
207-0060
“Extinguishing System Inoperative” complete IP65
207-0061
Special wording fascia only
207-0062
“Fire Alarm, Do Not Enter” fascia only
207-0063
207-0064
“Fire Alarm, Evacuate Area” fascia only
207-0065
“Do Not Enter, Gas Discharged” fascia only
“Fire Door Closing” fascia only
207-0066
“Do Not Enter” fascia only
207-0067
SOUNDERS
Vantage Sounder (Red/White)
205-0062/63
Vantage Combi (Red/White)
205-0066/67
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS
FireFinder
Conventional / Intelligent
Fire Alarm Control Panel
FireFinder is a state of the art multi microprocessor controlled Intelligent Fire Alarm
Control Panel. Modular in design, the FireFinder provides flexibility and versatility
that can be configured to operate with both intelligent analogue addressable and
conventional devices in the one system.
Available in single loop or multiple loop configurations, the FireFinder supports the
leading Apollo XP95 and Discovery detector protocols. The Ampac ConfigManager
software tools provide a powerful combination with the FireFinder to configure
the system operational and functional characteristics of an installation. Enhanced
networking capabilities offer the user extended applications with FireFinder
incorporating a Master/ Slave Fire control panel arrangement, true Peer to Peer systems,
data gathering panels and SmartGraphics a PC based application for the supervision,
monitoring and control of larger fire management systems.
•
•
•
•
•
•
•
•
•
•
•
•
Clear back-lit 40 character 8 line LCD display
Programming options via the front panel or laptop computer
Remote system interrogation and diagnostics
Extensive Alarm Management resources
Self Auto Learn capabilities
Day Night sensitivity settings
Versatile multi processor architecture
Event log and printer options
SPOT – Single Person Operation Test
Flexible modular expansion and panel Add Ons
Optional 32, 64, 96 & 128 zone indicators
SmartTerminal repeater options
AUS / PAGE 28
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent AS4428
FireFinder SP1X
Conventional / Intelligent Control Panel
FireFinder SP8X
Conventional / Intelligent Control Panel
Electrical
Power Supply
Output Voltage
Quiescent Current
Battery Capacity
85 to 264 VAC
27 VDC
450mA (min)
12 Ah (min)
Outputs
Bell 1 (monitored)
Bell 2 (monitored)
Auxiliary (monitored)
Auxiliary (unmonitored)
EWS (monitored)
EWS (unmonitored)
Fault
Isolate
Alarm
Valve Monitor
Battery Fail
Switched
Switched
Switched
Volt free
Switched
Volt free
Volt free
Volt free
Volt free
Volt free
Volt free
24 VDC 2A
24 VDC 2A
24 VDC 2A
1A @ 24 VDC
24 VDC 2A
1A @ 24 VDC
1A @ 24 VDC
1A @ 24 VDC
1A @ 24 VDC
1A @ 24 VDC
1A @ 24 VDC
Mechanical
Materials / Finish
1.2mm steel / Arch White powder coat
ConstructionModular
Dimensions
SP1X
500H x 405W x 145D mm
SP8X
840H x 515W x 170D mm
SP16X
1200H x 625W x 240D mm
10U
700H x 625W x 240D mm
16U
1200H x 700W x 350D mm
29U
1800H x 700W x 350D mm
SP1X Anc Cab
250H x 405W x 145D mm
SP8X Anc Cab
418H x 515W x 170D mm
Weight
SP1X
10 kg
SP8X
20 kg
SP16X
35 kg
10U
40 kg
16U
90 kg
29U
130 kg
SP1X Anc Cab
3 kg
SP8X Anc Cab
5 kg
AUS / PAGE 29
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional AS4428
FireFinder SP1X
Conventional Control Panel
FireFinder SP8X
Conventional Control Panel
FireFinder Conventional Control Panel
SP1X 16 Zone
SP1X 16 Zone EV20+Mic 5.6A
SP1X 16 Zone EV40+Mic 5.6A
SP8X 16 Zone 5.6A
SP8X 16 Zone EV40+Mic 5.6A
SP8X 16 Zone EV60+Mic 5.6A
SP8X 16 Zone EV120+Mic 18A
SP16X 16 Zone 5.6A
10U 16 Zone 5.6A
16U 16 Zone 5.6A
29U 16 Zone 5.6A
SP1X Ancillary Cabinet
SP8X Ancillary Cabinet
SP1X Surround
SP8X Surround
SP16X Surround
SP1X+Ancillary Cabinet Surround
SP8X+Ancillary Cabinet Surround
8550-1150
8550-1450
8550-1430
8550-4150
8550-4450
8550-4460
8550-4480
8550-5150
8550-6150
8550-6250
8550-6350
8510-9003
8510-9010
ENC1798-F
158-0033
ENC2844-F
ENC1797-F
158-0027
Note:
All panels have glazed outer doors
Additional 16 Zone and Loop Add-On Kits can be fitted
AUS / PAGE 30
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS FIREFINDER Intelligent AS4428
FireFinder SP1X
Intelligent Control Panel
FireFinder SP8X
Intelligent Control Panel
FireFinder Intelligent Control Panel
SP1X 1 Loop
SP1X 1 Loop EV20+Mic 5.6A
SP1X 1 Loop EV40+Mic 5.6A
SP8X 1 Loop 5.6A
SP8X 1 Loop EV40+Mic 5.6A
SP8X 1 Loop EV60+Mic 5.6A
SP8X 1 Loop EV120+Mic 18A
SP16X 1 Loop 5.6A
10U 1 Loop 5.6A
16U 1 Loop 5.6A
29U 1 Loop 5.6A
SP1X Ancillary Cabinet
SP8X Ancillary Cabinet
SP1X Surround
SP8X Surround
SP16X Surround
SP1X+Ancillary Cabinet Surround
SP8X+Ancillary Cabinet Surround
8550-1100
8550-1400
8550-1440
8550-4100
8550-4400
8550-4470
8550-4490
8550-5100
8550-6100
8550-6200
8550-6300
8510-9003
8510-9010
ENC1798-F
158-0033
ENC2844-F
ENC1797-F
158-0027
Note:
All panels have glazed outer doors
Additional 16 Zone and Loop Add-On Kits can be fitted
AUS / PAGE 31
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent
Network Interface Card (NIC) – 2 Wire Network
NE W
•The NIC gives the FireFinder network capabilities via the RS422
communications port
•Provides an additional RS232 communications port when connected
to Controller Interface Card (CIC)
•High level interface for Building Management or ModBus protocol for
SmartGraphics and PLCs
•The NIC can be isolated from other network devices
•Loop In/Loop Out for easy installation
Voltage
Quiescent Current
Available Ports
Max distance (between NICs)
Cable requirements
Operating temperature
Relative humidity
Weight
24 VDC
65 mA
RS422 – network
RS232 – serial comms
1.2km
RS422 – 2 pair twisted/screened
RS232 – 1 pair twisted/screened
-5°C to +55°C (no icing)
0 to 95% (non condensing)
225 grams
Network Interface Card – NIC (2 wire) NZ4512
SP1X159-0258
SP8X159-0259
SP16X/Rack159-0260
Add-On Kit
4310-0079
High Level Interface Expander or Port Expander Board
The High Level Interface Expander provides the ability for the FireFinder
Fire Alarm Control Panels (FACP’s) to support a range of high level interface
options. The physical interface between the FACP and equipment
can be RS232 or RS485.
Typical applications where the HLI Expander is used are:
•Building Management
•Paging system
•Nurse Call Systems
•EV3000
•SmartGraphics
•MODBUS
AUS / PAGE 32
CONTACT AMPAC
Supply Voltage
Quiescent current Max No. HLIE per FACP controller
Size
Ports
Max Distance
Cabling
27VDC
7.5ma
3
155 L x 72.5 W x 20 D mm
RS232RS485
15m
1.2kms
Multi-core
1 twisted pair +
cable+shieldshield
FireFinder High Level Interface Expander – Factory Fitted Inside Panel 159-0268
FireFinder High Level Interface Expander – Add-On Kit
4310-0080
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent
Analogue Loop Upgrade Kit
•This kit adds an intelligent analogue loop to the FireFinder
Control Panel
•For an odd numbered loop upgrade the kit consists of an I/O CPU
module, cable and termination card
•An even numbered loop upgrade consists of an I/O CPU module
and cable
Voltage
Quiescent current
Loop current
Operating temperature
Relative humidity
Weight
24 VDC
40 mA
250 mA max.
-5°C to +55°C (no icing)
0 to 95% (non condensing)
200 grams
1 Loop Upgrade Kit – even numbered loop SP1X
1 Loop Upgrade Kit and processor – odd numbered loop SP1X
Even No. Loop SP16X/Rack
Even No. Loop SP8
Odd No. Loop SP16X/Rack
159-0001
159-0003
159-0002
159-0046
159-0004
Module Expansion Kit for Modules (5–8)
•Expands the capacity of the FireFinder to accommodate a further four
loops, 64 conventional zones, four I/O modules or any combination of
the above
•Requires a main controller board
Note: O
ther expansion module kits are available with 16AZF/Loop/or I/O
modules pre-fitted to suit. Consult your Customer Service office for
more details.
AUS / PAGE 33
CONTACT AMPAC
HOME
CONTENTS
Voltage
Quiescent current
Operating temperature
Relative humidity
Weight
24 VDC
5 mA
-5°C to +55°C (no icing)
0 to 95% (non condensing)
110 grams
SP8X Loop Module Expansion Kit
SP16X/Rack Loop Module Expansion Kit
SEARCH
ZOOM
PRINT
159-0112
159-0022
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent
8 Way Serial Relay Output Board
•Each serial relay output board offers 8 voltage free relay outputs, each
rated at 5 amps, 24 VDC
•Each relay has a single normally open/close volt-free contact extended
to a wire-protected screw terminal
•The serial 8-way relay is driven directly from the main controller board
Voltage
Quiescent current
Relay output current
Operating temperature
Relative humidity
Weight
24 VDC
5 mA
5 Amps at 24 VDC
-5°C to +55°C (no icing)
0 to 95% (non condensing)
190 grams
Rack 8 Way Serial Relay Output Board
SPX 8 Way Serial Relay Output Board
159-0072
159-0079
4 Plus 4 Bell Monitor Board
•The 4 Plus 4 Bell Monitor has screw terminals for 4 voltage free contacts
and 4 switched 24V DC sounder outputs
• The outputs are programmable and monitored for open or short circuit
• The board connects directly to the main controller board
Voltage
Quiescent current
Relay output current
Sounder output current
Capacity
Operating temperature
Relative humidity
Weight
24 VDC
20 mA
1 Amp at 24 VDC
1 Amp each
8 boards per main controller
-5°C to +55°C (no icing)
0 to 95% (non condensing)
250 grams
4 Plus 4 Bell Monitor Board
AUS / PAGE 34
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
159-0069
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent- Add Ons
Fire Fan Module
Each Fire Fan Module houses the control and indication of up to four (4)
fire fans and a single control/indication for plant trip reset.
A hard-wired version of a fire fan module consists of a Fire Fan Control
Card and Termination Board. Field wiring is terminated to the termination
board at the FACP.
A loop-driven version is also available and in this configuration only the
Fire Fan Control Card would be required. Field wiring will terminate to
address input/output devices that operate on the addressable loop.
•Four (4) Controls per Module
•Status indication for Run / Fault / Stop
•Controls for ON / Auto / Off
•Audible and visual feedback of button press
•Built in Plant Trip Reset
•Supports 3, 4 and 5 Wire Connections
•Available in Hardware or loop driven versions
•Communicates with FACP via RS485 communication port
•Where applicable all terminals cater for 2.5mm² cables
AUS / PAGE 35
CONTACT AMPAC
HOME
CONTENTS
Operating Voltage
27VDC
Dimensions:
Fits standard Panel Cut-Out
Controller Card
Termination Board
155mm x 72mm
Contact Rating
1 @ 24VDC
ApprovalAS1668
System Capacity:
15 Maximum
FireFinder
LoopSense
15 Maximum
ZoneSense Plus
1 Maximum
Hard Wired
Loop Driven
Slip in Label Template
SEARCH
ZOOM
4310-0021
4310-0071
LAB1486
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent
8-Way 5A Relay
•Each upgrade panel add-on offers 8 voltage free relay outputs. E ach
output is rated at 5 amps, 24 VDC
•Each relay has a single normally open/close volt-free contact extended
to a wire-protected screw terminal
•The standard 8-way relay upgrade requires spare capacity available on
a 128/128 I/O and 16/16 I/O module
Voltage
Quiescent current
Operating temperature
Relative Humidity
Weight
24 VDC
5 mA (Serial Relay Board)
-5°C to 55°C (no icing)
0 to 95% (non condensing)
190 grams
SPX 8-Way 5A O/P Relay
Rack 8-Way 5A O/P Relay
AUS / PAGE 36
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
159-0013
159-0015
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent
8 Way Bell Monitor Board
•The 8-Way Bell Monitor has 8 switched 24V DC sounder outputs
• The outputs are programmable and monitored for open or short circuit
• The board connects directly to the main controller board
Voltage
Quiescent current
Max sounder output current
Max output current
Operating temperature
Relative humidity
Weight
24 VDC
20 mA
1 Amp each
4 Amps per board
-5°C to +55°C (no icing)
0 to 95% (non condensing)
250 grams
8 Way Bell Monitor Board
159-0071
16 Way Conventional Zone Card
• Adds 16 conventional Alarm Zone Circuits
•Kit consists of an I/O CPU module, cable and 16 zone termination card
•Supports up to 40 conventional detectors (Series 60, Series 65 or Orbis)
per zone
•Fixed 3K3 End-Of-Line device
•Supports Ampac NZ detector models
Voltage
Quiescent current
Operating temperature
Relative humidity
Weight
24 VDC
145 mA
-5°C to +55°C (no icing)
0 to 95% (non condensing)
185 grams
SP8X/SP16X 16 Way Conventional Zone Card
Rack 16 Way Conventional Zone Card
AUS / PAGE 37
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
159-0005
159-0006
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent
16 Opto Inputs
•The Opto Input panel add-on provides 16 programmable electrically
isolated inputs to the FACP
• The input from a third party source should be a volt-free contact
•This upgrade requires spare capacity available on a 128/128 I/O and
16/16 I/O Interconnect Module
Voltage
Quiescent current
Operating temperature
Relative Humidity
Weight
24 VDC
5 mA
-5°C to 55°C (no icing)
0 to 95% (non condensing)
185 grams
SP 16 Opto Input
Rack 16 Opto Input
159-0010
159-0011
Modem
•The modem allows a remote access to FireFinder
•Configuration and application software can be uploaded or
downloaded via the modem
•Wireless Modem requires available signal from appropriate network
•All modems are AUSTEL approved
•Great tool to provide remote support
Voltage
Data transfer rate
Comms to FACP
Operating temperature
Relative Humidity
Weight
27 VDC
9600 baud max
RS 232
-5°C to 55°C (no icing)
0 to 95% (non condensing)
SP & Rack: 1kg
Wireless: 5kg
SPX Modem
Rack Modem
Wireless Modem
AUS / PAGE 38
CONTACT AMPAC
HOME
CONTENTS
SEARCH
159-0033
159-0065
159-0068
ZOOM
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent- Add Ons
8 Way Switch and Indicator Card
•8 x Push Button On / Off switches
•8 x LED display of the On / Off condition
•Controls and Monitors solenoid test switches, manual shutdowns and
etc
•Programmable via the ZoneSense PLUS front panel
•Programmable via ConfigManager for the FireFinder range of panels
•Programmable via LoopMaster for the LoopSense range of panels
Voltage24VDC
3.6mA
Quiescent Current
Max Current
8mA
Operating Temperature
-5°C - 55°C (no icing)
Relative Humidity
0 to 95% (non condensing)
Weight100grams
System Capacity
FireFinder
15 Maximum
LoopSense
15 Maximum
ZoneSense Plus
1 Maximum
Switch and Indicator Card
Slip In Label
AUS / PAGE 39
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
4310-0030
LAB 1483
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent- Add Ons
Agent Release System AS4214
The Agent Release System comprises of the Main Control Card,
Termination Board and Local Control Stations. In addition a yellow Manual
Call Point can be supplied to fit to the main Fire Alarm Control Panel (FACP)
(This is a requirement of AS4214 Agent Release Systems)
The Agent Release System can be configured to operate
in a single group or dual group mode.
•Controls and Monitors Agent Release System
•Outputs for Warning Signs and activation devices
•Inputs for signals from pressure switches & valves
•Serial connection to Agent Release Local Control Station (LCS)
•Programmable via the ZoneSense PLUS front panel
•Programmable via ConfigManager for the FireFinder range of panels
•Programmable via LoopMaster for the LoopSense range of panels
Pressure Switch Input
Monitored Input
Monitored Input
Low Pressure Switch Input
Monitored Input
Interlock Input
Gas Fired Output
Volt Free Changeover
[email protected]
System Inoperative Output
Volt Free Changeover
[email protected]
Stage 1 Output
Monitored
Stage 2 Output
Monitored
Release Initial Agent Output
Monitored current limited
2A max
Monitored current limited
Release Reserve Agent Output
2A max
System Capacity
FireFinder
8 Maximum
LoopSense
8 Maximum
ZoneSense Plus
1 Maximum
Agent Release Kit
4310-0011
Local Control Station AS4214
A maximum of 8 LCS's can be connected remote to the panel. An operator
may manually release or inhibit release from any of these LCS's.
•RS485 serial connection from the FireFinder FACP to the Agent Release
Local Control Station (LCS)
•A 20mm knock out is provided in the top and bottom of the LCS metal
enclosure
AUS / PAGE 40
CONTACT AMPAC
HOME
CONTENTS
Inhibit Agent Release
Manual release
Push button hinged cover
MCP with hinged cover
Local Control Station
SEARCH
ZOOM
4310-0019
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent – Ancillary Products
Agent Release Warning Signs
The AR panel supports a 2-wire connection to warning signs. The 2-wire
connection supports both single or dual stage signs. The latter is possible
because of the voltage reverse technology adopted by the AR panel.
Multiple warning signs may be connected to the AR panel. The connection
will be in a ‘daisy chain’ configuration with the last warning sign fitted with
an End-Of-Line (EOL) resistor. The EOL resistor facilitates the monitoring of
the warning sign circuit. A maximum of 6 warning signs may be fitted
to an AR panel.
An on-board buzzer fitted to every sign provides audible warning.
However in the event AS1670.4 audible warning tones are required,
external electronic sounders may be connected directly to each warning
sign. An external switch may be connected to the sign to mute audible
warning.
AUS / PAGE 41
CONTACT AMPAC
HOME
CONTENTS
ACP-04 Manual Call Point Yellow
ACP-04 Manual Call Point Hinged Cover
213-0061
213-0057
IP50 SIGNS
Warning sign back box (IP50) no fascia207-0050
“Extinguishing System Inoperative” complete IP50
207-0051
Special wording fascia only
207-0052
“Fire Alarm, Do Not Enter” fascia only
207-0053
207-0054
“Fire Alarm, Evacuate Area” fascia only
“Do Not Enter, Gas Discharged” fascia only
207-0055
“Fire Door CLosing” fascia only
207-0056
“Do Not Enter” fascia only
207-0057
IP65 SIGNS
Warning sign back box (IP65) no fascia
207-0060
“Extinguishing System Inoperative” complete IP65
207-0061
Special wording fascia only
207-0062
“Fire Alarm, Do Not Enter” fascia only
207-0063
207-0064
“Fire Alarm, Evacuate Area” fascia only
207-0065
“Do Not Enter, Gas Discharged” fascia only
“Fire Door Closing” fascia only
207-0066
“Do Not Enter” fascia only
207-0067
SOUNDERS
Vantage Sounder (Red/White)
205-0062/63
Vantage Combi (Red/White)
205-0066/67
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent
Panel Mounted LED Indicators
•Provide flexibility to include additional LED indicators to the FireFinder
SP1X and SP8X
•Available in three versions:
– 32 zone alarm only indication (red)
– 16 zone alarm/fault indication (red/amber)
– 32 zone general indication (amber)
•Serial connection to the FireFinder panel
•Simple clip installation
•Indicators remain illuminated until reset by the panel
•Indicators are tested by the FireFinder panel’s lamp test control
AUS / PAGE 42
CONTACT AMPAC
HOME
CONTENTS
Voltage
Quiescent current
Max current
Operating temperature
Relative humidity
Weight
27 VDC
30 mA
40 mA
-5°C to +55°C (no icing)
0 to 95% (non condensing)
100 grams
FireFinder SP1X 32 Zone Alarm Only Indication (Red)
FireFinder SP8X 32 Zone Alarm Only Indication (Red)
159-0106
159-0089
FireFinder SP1X 16 Zone Alarm/Fault Indication (Red/Amber)
FireFinder SP8X 16 Zone Alarm/Fault Indication (Red/Amber)
159-0107
159-0108
FireFinder SP1X 32 Zone General Indication (Amber)
FireFinder SP8X 32 Zone General Indication (Amber)
159-0123
159-0124
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent
Remote Mounted LED Indicators
•The remote LED indicator boards provide facilities to mimic the
FireFinder zone LEDs and switches
•Connects to the RS485 communications bus via the controller interface
card
•Allows the custom design of geographic site layout mimics
•Each termination board connects up to 32 zone LEDs – 31 boards
maximum – total 992 zone indications
FireFinder LED Mimic Driver
Voltage
Quiescent current
Max current
Communication mode
Baud rate
Communication cable
No. of boards
No. of zones
Buzzer external max current
On board status indication
Common inputs
Operating temperature
Relative humidity
27 VDC
8 mA max
100 mA
RS485
19200 max
1 x pair twisted and screened
31 max
992 zones max
20 mA
Power on – green
Normal – green
Fault – yellow
Reset
Lamp test
Buzzer mute
Bell isolate
Manual evacuate
-5°C to +55°C (no icing)
0 to 95% (non condensing)
FireFinder LED Mimic Driver 32 Way
Mimic Output Termination Board
FireFinder 16 Zone LED Display Board
Mimic Output Termination Board
159-0145
159-0152
159-0218
Remote Expansion LED Board
AUS / PAGE 43
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
CONTROL PANELS FIREFINDER Conventional / Intelligent
Fibre Optic Network Interface
The fibre optic network interface kit offers the user a method of
interconnecting two (2) or more networked FireFinder Fire Alarm Control
Panels (FACP) using fibre optic cable as an alternative to copper wire. Each
FACP will require a kit. Each kit comprises of 2 modem interfaces plus
cables.
•4 versions available to suit your cabling scheme on site
•Redundant loop integrity (same as copper)
•A network interface card is still required at each FACP node
•Maximum distance using ‘Multimode’ (between nodes) up to 5km;
using Single Mode 50km
AUS / PAGE 44
CONTACT AMPAC
HOME
CONTENTS
Supply Voltage
24 VDC
80 mA @ 24 VDC
Quiescent Current
ST standard
Optical Connector
Ports Available
RS422/RS485
Size (mm)
104D x 104W x 25H
Weight280g
-20°C to +75°C
Operating Temperature
0 to 95% relative,
Humidity
non-condensing
Item
FireFinder Fibre Optic Multimode 2 core
FireFinder Fibre Optic Multimode 1 core
FireFinder Fibre Optic Single mode 2 core
FireFinder Fibre Optic Single mode 1 core
SEARCH
ZOOM
PRINT
Max Distance
between Nodes
5km max
5km max
50km max
50km max
EXIT
Code
159-0251
159-0252
159-0253
159-0254
EMERGENCY WARNING SYSTEMS
Emergency Warning Systems
The Ampac EV3000 Occupant Warning and Intercom System is designed for the
purpose of enabling the orderly evacuation of occupants, from a building or structure,
in the event of an emergency.
The system comprises of two (2) sub-systems. The first being the Occupant Warning
System (OWS) and the other the Occupant Intercom System (OIS). While the Warning
and Intercom System have separate controls, they coexist in a panel that is logically
presented and aesthetically pleasing.
The Occupant Warning System makes use of speakers strategically placed around the
site, to broadcast ALERT, and/or EVACUATION signals or public address announcements.
The OWS may be automatically initiated or manually operated. When not used in an
emergency situation, the EV3000 can broadcast background music and/or general
paging announcements.
The Occupant Intercom System (OIS) consists of front panel control at the Emergency
Control Panel (ECP) and Warden Intercom Phones (WIP) that are strategically placed
throughout the building. Communication is only possible between the WIP and ECP.
For larger sites, multiple control panels may be networked.
AUS / PAGE 45
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
EMERGENCY WARNING SYSTEMS
Emergency Warning Systems
•Modular system design – can be easily customised to meet special requirements
•Discrete front panel control – ‘natural’ style layout easy to locate zones
•Amplifiers available: 40, 120, 240 & 480-watts – choice of amplifiers to suit your need
•Visual output for hearing impaired or noisy environments
•Common or individual fire alarm inputs – an “all call” or staged evacuation may be
configured
•2-wire Warden Intercom Phones (WIP) – monitored for open and short circuit
•Common or zoned background music inputs – non-emergency input gives EV3000
the flexibility to fit most applications including shopping centres, hospitals, etc
•Monitoring of speaker circuits – monitoring for short or open circuit
•Monitoring of Visual Warning indicators – monitoring for short or open circuit
•Automatic volume control incorporating ambient noise sensing microphone – ideal
for applications where the ambient noise levels are different at various times of day
•Fail safe volume override output – used as a control to shutdown all non-emergency
facilities offered by the EV3000 and to override attenuated volume controls located
in the field
•Stand-by signal generators – provides 100% backup of emergency tones for greater
reliability
•Stand-by microphone amplifiers – provides 100% backup of emergency public
address for greater reliability
•Automatic changeover to stand-by amplifier – may be configured in the event an
active amplifier is faulty
•Digital paging console – attractive remote paging console with seven (7) segment
digital display and keypad gives operator quick and easy access to paging zones
•Networked system – expands EV3000 features to include master / sub panel
configuration, and remote paging console
•Optic Fibre Interface – the optional Optic Fibre interface allows the EV3000 to be
networked over optic fibre cables
AUS / PAGE 46
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel
Mechanical
Material
Finish
Dimensions
Approvals
Signals
EV3000 12U
AUS / PAGE 47
Electrical
Power Supply
7.5, 13, 19.5 or 26 A mps @ 24 VDC
RS485 @ 9600 bps
Communication
EWS Zones
144 max
EIS Zones
288 max
8 max (recommended)
Paging Console
12 max (recommended)
ECP’s
Visual Warning
Option 1EV3000 Visual Outputs Maximum of 8 pairs per visual circuit
(for Xenon 208-0011). Not T3 compliant
Option 2EV3000 Visual Outputs Maximum of 40 pairs per visual circuit
(for LED 208-0063). T3 compliant
Note: The LED visual pairs require the Ampac 4210-0031 Visual
Driver Kit fitted
EV3000 16U
EV3000 29U
EV3000 29U Double Rack
CONTACT AMPAC
1.6mm Mild Steel
Powder Coated Arch White
10U 700H x 625W x 240D mm (SEC P only)
12U 900H x 650W x 290D mm
16U 1200H x 700W x 375D mm
29U 1800H x 700W x 375D mm
SSL – AS2220.89
Compliant with AS1670.4:2004
HOME
EV3000 Emergency Control Panel
12U MECP
16U MECP
29U MECP
29U Double Cabinet MECP
10U SECP
12U SECP
16U SECP
29U SECP
CONTENTS
SEARCH
105-0001
105-0002
105-0003
105-0007
105-0004
105-0005
105-0006
105-0009
ZOOM
PRINT
EXIT
EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons
40 Watt Power Amplifier
• A modular power amplifier that is rated at 40 watts
•Multi-channel audio input supports Alert tone, Evacuation tone, Public
Address, and background music
• Continuous monitoring of amplifier and 100 volt speaker circuit
• Overload protection with Automatic
• Easily plugs into an Ampac EV3000 amplifier frame
• Can fit up to 8 amplifiers per frame
Voltage
24 VDC
58mA
Quiescent current
Max current
3400mA
Max output power
40 Watts
Output voltage
100 VAC RMS
Freq. Response
150Hz to 12kHz (±1dB)
Max 1% at full load
Distortion
(typical 0.5%)
Sensitivity
+5dB <200Kohm balanced)
(1.4VRMS)
Overload
100 VRMS + 10%
675 grams
Weight
40 Watt Power Amplifier
154-0075
120 Watt Power Amplifier
•A modular power amplifier that is rated at 120 watts
•Multi-channel audio input supports Alert tone, Evacuation tone, Public
Address, and background music
•Continuous monitoring of amplifier and 100 volt speaker circuit
•Overload protection with Automatic
•Easily plugs into an Ampac EV3000 amplifier frame
•Can fit up to 4 amplifiers per frame
Voltage
Quiescent current
Max current
Max output power
Output voltage
Freq. Response
Distortion
Signal to Noise
Overload
Weight
24 VDC
175mA
8100mA
120 Watts
100 VAC RMS
210Hz to 14.5kHz (±1dB)
< 0.2% at full load
77 dB
100 VRMS + 10%
1160 grams
120 Watt Power Amplifier
AUS / PAGE 48
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
154-0077
PRINT
EXIT
EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons
240 Watt Power Amplifier
•24v DC supply
•Mother board address strapping (120 address positions)
•Continuous fault monitoring
•Volume override output
•Test tone input
•Data selectable 4 channel input (balanced)
•Tone generator synchronisation input
•Indication (power on - green, power shutdown - yellow, amp or line
fault - red, overload - red)
•Minimum cable size 2.5mm²
Voltage
Quiescent current
Max current
Max output power
Output voltage
Freq. Response
Distortion
Signal to Noise
Overload
Weight
24 VDC
350mA
16200mA
240 Watts
100 VAC RMS
210Hz to 14.5kHz (±1dB)
< 0.2% at full load
77 dB
100 VRMS + 10%
2320 grams
240 Watt Power Amplifier
154-0001
480 Watt Power Amplifier
•24v DC supply
•Mother board address strapping (120 address positions)
•Continuous fault monitoring
•Volume override output
•Test tone input
•Data selectable 4 channel input (balanced)
•Tone generator
•Indication (power on - green, power shutdown - yellow, amp or line
fault - red, overload - red)
•Minimum cable size 4mm²
24 VDC
700mA
32400mA
480 Watts
100 VAC RMS
210Hz to 14.5kHz (±1dB)
< 0.2% at full load
77 dB
100 VRMS + 10%
4640 grams
Voltage
Quiescent current
Max current
Max output power
Output voltage
Freq. Response
Distortion
Signal to Noise
Overload
Weight
480 Watt Power Amplifier
AUS / PAGE 49
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
154-0002
PRINT
EXIT
EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons
Emergency Alarm Initiating Device (EAID)
• Connects to S004 WIP
•2 wires for WIP & EAID
•Compatible with 219-0015
Emergency Alarm Initiating Device (EAID)
213-0068
Warden Intercom Phone – 2 Wire (S0004)
• 2 Wire WIP/EAID wiring
•High quality WIP audio
•Complies with AS4428.4
•Suitable for models manufactured after July 2010
Operating Voltage
Line Voltage
Current draw
Line Impedance
Line Level
Cabling
Dimensions
Weight
27 VDC (line driven)
On hook - 25 VDC max
Off hook - 14 VDC max
On hook - 5 mA max
Off hook - 35 mA max
360 ohm balanced
0 dB (± 3dB)
2 wire - 2.5mm² max.
215H x 85W x 62D mm
380 grams
Warden Intercom Phone – 2 Wire (S0004)
WIP Enclosure Metal Surface Mounted
AUS / PAGE 50
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
219-0015
291-0054
EXIT
EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons
Warden Intercom Phone – 3 Wire
•The WIP is installed remote to the ECP
•Provides intercommunication between users at the WIP and
Emergency Control Panel
•This feature is only available when the Emergency Warning Intercom
facility has been incorporated in the control panel
•Made of high impact red ABS plastic
•Compatible with most EV3000 systems manufactured before July 2010
27 VDC (line driven)
On hook - 25 VDC max
Off hook - 14 VDC max
On hook - 5 mA max
Off hook - 35 mA max
360 ohm balanced
0 dB (± 3dB)
3 wire - 2.5mm² max.
215H x 85W x 62D mm
380 grams
Operating Voltage
Line Voltage
Current draw
Line Impedance
Line Level
Cabling
Dimensions
Weight
Warden Intercom Phone – 3 Wire
WIP Enclosure Metal Surface Mounted
219-0007
291-0054
Remote Paging Console
•Provides a point to initiate a non-emergency voice announcement via
the EV3000
•Provides a pre-announcement tone
•Easy keypad operation to broadcast voice announcements to selected
zones, or group of zones
•Connects to EV3000 via RS485
•Derives power from the EV3000 panel
AUS / PAGE 51
CONTACT AMPAC
HOME
CONTENTS
Size
Supply voltage
Current
Communication
Weight
80H x 300W x 220D mm
12 VDC
400 mA
RS 485
1160 grams
Remote Paging Console
SEARCH
ZOOM
154-0005
PRINT
EXIT
EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons
Fibre Optic Network Interface for EV3000
The fibre modem network interface kit offers the user a method of
interconnecting two (2) or more EV3000 Emergency Warning and
Intercom System (EWIS) using fibre optic cable as an alternative to copper.
The modems convert hardwired data and audio, to a common fibre optic
compatible output.
The fibre optic modems are full duplex and have 4-channels to carry both
data and two (2) audio signals. Two (2) channels are required – emergency
public address and warden intercom audio signals.
Supply Voltage
12 VDC
300 mA
Quiescent Current
Input Ports Available
RS422
Emergency P.A.
Warden Intercom Phone Audio
Max. Distance
5 km
2-core multimode fibre
Cabling
ST Standard
Fibre Connector
Optical Data
Wavelength850nm
ModeMultimode
LED
Emitter type
Operating Temperature
0°C to +55°C
0 to 95% (no icing)
Relative Humidity
(non condensing)
Size
L104 x W144 x D25 mm
Fibre Optic Network Interface for EV3000
154-0005
Combined Strobe for EV3000 (Flush)
Combined Strobe for EV3000 (IP65 )
Combined Strobe for EV3000 (Surface )
208-0066
208-0065
208-0066
Combined Strobe for EV3000 (Surface Mount)
Item pictured is 208-0066 Indoor. The IP65 model uses the deep base to
achieve an outdoor solution where required.
AUS / PAGE 52
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
EMERGENCY WARNING SYSTEMS Speakers
Ceiling Speaker – 100mm Recessed
•100 mm recessed ceiling speaker
•Operates with 100 volt speaker line
•Capacitor fitted for line monitoring
•Five (5) power output settings
•Safety cover to protect terminals
•Facility to secure field cabling to speaker housing
•Optional low profile grill available
Rated Power
Line Voltage
Frequency R esponse
SPL
Speaker Tap (watt)
Cut-out size
Dimensions
Weight
5 watts
100 Volt
100 Hz to 20 kHz
96 dB (1 watt @ 0.5m)
0.33, 0.66, 1.25, 2.5, 5
85 mm Diameter
100 x 105 Hmm
800 grams
Ceiling Speaker – 100mm Recessed
Low Profile Grill
218-0008
218-0003
Ceiling Speaker – 200mm Recessed
•200 mm recessed ceiling speaker
•Operates with 100 volt speaker line
•Capacitor fitted for line monitoring
•Five (5) power output settings
•Safety cover to protect terminals
•Facility to secure field cabling to speaker housing
•Optional low profile grill available
Rated Power
Line Voltage
Frequency R esponse
SPL
Speaker Tap (watt)
Cut-out size
Dimensions
Weight
5 watts
100 Volt
100 Hz to 20 kHz
96 dB (1 watt @ 0.5m)
0.33, 0.66, 1.25, 2.5, 5
190 mm Diameter
200 x 75 Hmm
1 kg
Ceiling Speaker – 200mm Recessed
Low Profile Grill
AUS / PAGE 53
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
218-0009
218-0021
EXIT
EMERGENCY WARNING SYSTEMS Speakers
Ceiling Speaker – 100mm One-Shot
•100 mm quick-fit recessed ceiling speaker
•Operates with 100 volt speaker line
•Capacitor fitted for line monitoring
•Five (5) power output settings
•Safety cover to protect terminals
•Facility to secure field cabling to speaker housing
•Speaker grill incorporated with speaker
Rated Power
Line Voltage
Frequency R esponse
SPL
Speaker Tap (watt)
Cut-out size
Dimensions
Weight
5 watts
100 Volt
100 Hz to 15 kHz
98 dB (1 watt @ 0.5m)
0.33, 0.66, 1.25, 2.5, 5
140 mm Diameter
155 x 110 Hmm
850 grams
Ceiling Speaker – 100mm One-Shot (White)
Ceiling Speaker – 100mm One-Shot (Black)
Ceiling Speaker – 200mm One-Shot (White)
218-0026
218-0031
218-0032
Surface Speaker – 100mm
•Custom designed speaker and transformer assembly engineered to
meet Australian Fire Evacuation Standards
•High degree of speech intelligibility
Driver
Power taps
SPL 1W @ 1m
Frequency response
Connection
100mm (4”) dual cone
0.33, 0.66, 1.25, 2.5, 5W
90dB @ 1kHz (+/- 2dB)
100Hz-15kHz
4 way terminal block + 22uF bipolar capacitor
Surface Speaker – 100mm
AUS / PAGE 54
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
218-0022
PRINT
EXIT
EMERGENCY WARNING SYSTEMS High Efficiency Speakers
EasyFit Ceiling Speakers
•In four useful sizes: 4”, 5”, 6.5”, 8”
•Choice of power rating: 5W, 10W, 15W, & 30W
•Wide bandwidth for music reproduction
•Wide dispersion for speech intelligibility
•Simple output-level selection
•Easily flush-mounted in ceilings or bulkheads
•Dependable rota-clamp fixing system
•Blends in with virtually all interiors
4 Inch 5 Watt
5 Inch 5 Watt
6 Inch 10 Watt
8 Inch 15 Watt
8 Inch 30 Watt
4”5”6.5”
8”8”
Driver
8W/5W 8W/5W 15W/10W22W/15W45W/30W
Maximum/rated power
Power taps
5, 2.5, 1.25, 0.66, 0.33W
5, 2.5, 1, 0,5, 0.33W
10, 5, 2.5, 1.25W
15, 10, 5, 2.5, 1.25W
30, 15, 7.5, 3.75W
Frequency Range
100Hz - 15kHz
50Hz - 17kHz
60Hz - 20kHz
50Hz - 17kHz
50Hz - 17kHz
Axial sensitivity 1W/1m/1kHz
94dB SPL
97dB SPL
91dB SPL
93dB SPL
93dB SPL
Opening Angle( -6dB)
144° / 93° at 1kHz / 4kHz 170° at 1kHz
170° at 1kHz
165° at 1kHz
100° at 1kHz
140mm170mm195mm238mm238mm
Ceiling cutout diameter
170mm x 110mm
202mm x 90mm
220mm x 115mm
273mm x 103mm
273mm x 115mm
Overall dimensions
Safety
acc to EN 60065
acc to EN 60065
acc to EN 60065
acc to EN 60065
acc to EN 60065
Ceiling Speaker, Easyfit 5w 4” - EVAC
Ceiling Speaker, Easyfit 5w 5” - Brilliant White
Ceiling Speaker, Easyfit 5w 5” White
Ceiling Speaker, Easyfit 10w 6.5”
Ceiling Speaker, Easyfit 15w 8” White
Ceiling Speaker, Easyfit 30w 8” White
AUS / PAGE 55
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
218-0041
218-0042
218-0043
218-0044
218-0045
218-0046
EXIT
EMERGENCY WARNING SYSTEMS Speakers
Horn Speaker – 10 Watt
•10 watt Flared horn speaker
•Operates with 100 volt speaker line
•Capacitor fitted for line monitoring
•Five (5) power output settings
•High SPL performance
•Weatherproof construction
•Mounting bracket supplied
Rated Power
Line Voltage
Frequency R esponse
SPL
Speaker Tap (watt)
Dispersion angle
Material
IP Rating
Dimensions
Weight
10 watts
100 Volt
250 Hz to 13 kHz
105 dB (1 watt @ 1m)
1.25, 2.5, 5, 7.5, 10
110°
UV stabilised plastic
IP65
150 Dia x 190 Dmm
1.4 kg
Horn Speaker – 10 Watt
218-0028
Horn Speaker – 20 Watt
•20 watt Flared horn speaker
•Operates with 100 volt speaker line
•Capacitor fitted for line monitoring
•Five (5) power output settings
•High SPL performance
•Weatherproof construction
•Mounting bracket supplied
20 watts
100 Volt
270 Hz to13 kHz
108 dB (1 watt @ 1m)
2.5, 5, 7.5, 10, 15, 20
110°
UV stabilised plastic
IP65
200 Dia x 290 Dmm
1.5 kg
Rated Power
Line Voltage
Frequency R esponse
SPL
Speaker Tap (watt)
Dispersion angle
Material
IP Rating
Dimensions
Weight
Horn Speaker – 20 Watt
AUS / PAGE 56
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
218-0007
PRINT
EXIT
EMERGENCY WARNING SYSTEMS High Efficiency Speakers
Horn Speaker – 10 Watt / 20 Watt
•10W & 20W Models available
•IP66 Rated
•Emergency Evacuation System ready
•Wide dispersion for speech intelligibility
•Screwdriver adjustable power tapping
•Loop in / Loop out wiring
10 Watt
100V
10W
10, 7.5, 5, 2.5,
1.25
119 dB
108 dB
300Hz - 13kHz
140°@1kHz
1.3KG
Rated input
Power handling
Power taps
SPL at Rated Power (10W @ 1m)
SPL at Rated Power (1W @ 1m)
Frequency Range (-10dB)
Dispersion Angle(-6dB)
Weight
Horn Speaker – 10 Watt
Horn Speaker – 20 Watt
20 Watt
100V
20W
20, 15. 10,
7.5, 5W
124 dB
110 dB
9kHz
90°@1kHz
2.1KG
218-0047
218-0048
Speaker Attenuator
•Operates in conjunction with an Emergency Warning System (EWS)
•Attenuates the sound level of speakers in the circuit during normal
operation of the EWS
•7-step attenuator setting including ‘OFF’ position
•Switched 24 VDC (fail-safe operation) enables attenuation control
•Screw driver terrminals for easy wiring
Rated Power
40 or 100 watts
100 Volt
Speaker L ine Voltage
Attentuation
0, 5.7, 9.8, 16, 20, 26.3dB, ∞
24 VDC
Override Relay Operating Voltage
White UV stabilised plastic
Material
Dimensions
Suits single gang wall box
(Australian)
Weight
300 g
Speaker Attenuator – 40 Watt 100V
Speaker Attenuator – 100 Watt 100V
AUS / PAGE 57
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
225-0002
225-0003
EXIT
GRAPHICS PACKAGE
SmartGraphicsHD
A FireFinder FACP compatible product
AMPAC’s SmartGraphicsHD System unleashes the full power of FireFinder (fire
detection) and the EV3000 (alarm and intercom) by creating a robust and versatile hub
for controlling your fire detection, alarm and intercom systems with one fully integrated
package. Flexible and intuitive in its design, SmartGraphicsHD puts the command of
your systems at your fingertips.
• Interfaces to the FireFinder fire detection panel and the EV3000 emergency warning and intercom system
• Clearly shows on the building floor plan the start and spread of the fire and the status of the emergency warning and intercom system
• Has capabilities of e-mailing maps to emergency service organisations and key stakeholders
• Supports the latest 1920x1080 HD computer technology
• Able to operate over existing IT infrastructure
• Can be expanded to incorporate multi-site facilities into one central monitoring package
• Historic data log on the activity of the fire detection system and alarm system
• Three level password protection
• Detailed Egress Pathways
• Building Information (like hazardous materials) and mustering point displayed on maps
AUS / PAGE 58
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
GRAPHICS PACKAGE
Graphics Package
Computer (Rec Min)
Monitor
RS232 Comms
RS485 Comms
Ethernet
Intel Core Processor 2Ghz, 2GB RAM, 500 GB Hard Drive, CDROM, 6 USB Ports
Serial Comms port for connection to FACP (RS232 or RS485 as required)
Windows XP Professional (32bit) , or
Windows 7 Professionl (32bit)
20” min (resolution 1920 x 1080)
1 pair twisted & screened
15m maximum from FireFinder
Baud rate- 9600 to 38400
1 pair twisted & screened
1200m maximum from FireFinder
8 pin RGRJ45 Connector
10/100 Mbps IEEE 802.3. IEEE 802.38
SmartGraphicsHD
Licence Package Only
4100-0002
Licence Package and computer - including a colour laser printer
4100-0003
4100-0004
Licence Package and embedded computer with touch screen
- including a colour laser printer
Licence Package and computer with touch screen monitor
4100-0005
- including a colour laser printer
Ethernet159-0613
* Graphical Engineering available- please contact your local CSO Office.
AUS / PAGE 59
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
DETECTORS
Orbis
Conventional Detectors
Orbis is a range of conventional detectors which has been developed with sophisticated
technology previously only found in intelligent detectors. Orbis is a range with modern
styling and incorporates a mounting base wihich saves installation time.
• Automatic drift compensation with DirtAlert® warning
• Patented FasTest® which reduces the time taken to test detectors
• SensAlert® uses a flashing LED to indicate that the sensor is not operating correctly
• StartUp™ for fast commissioning
• Attractive and compact design
• Electrically compatible with Series 60 and Series 65
• Wide voltage and operating temperature ranges
• Algorithms for transient rejection
• Flashing LED option
• 360° visibility of LEDs
• Insect resistant
AUS / PAGE 60
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
DETECTORS
ORBIS Conventional
Orbis Optical Smoke Detector (AS)
The Orbis Optical Smoke Detector works using the well established light
scatter principle, however, the sensing technology is radically different
in design from previous optical detectors and significantly reduces false
alarms.
•
•
•
•
•
•
Responds well to slow-burning, smouldering fires
Performs well in black and white smoke
Extra confirmation of smoke before alarm signal is given
Reduced incidence of false alarms
Sensing chamber keeps out dust and other airborne contaminants
Operates over a broad range of voltages at extremes of temperature
Operating voltage
Quiescent current
Alarm current
Remote output
Size
Operating temperature
Relative humidity
IP rating
Weight
8.5 to 33 VDC
65μA at 24 VDC
40mA at 24 VDC
1.2kΩ to -ve supply
97Dia x 31H mm
-40°C to +70°C (no icing)
0 to 98% (non condensing)
IP23D (EN60529)
75 grams
Orbis Optical Smoke Detector (AS)
201-0512
Approvals: AS7240.7/CSIRO
Orbis Multisensor Detector (AS)
The Orbis Multisensor Detector benefits from the same false alarm
reduction technology as the optical detector. It is a thermally enhanced
smoke detector and so will not give an alarm from heat alone.
•
•
•
•
•
Responds well to fast-burning, flaming fires
Reduced incidence of false alarms
Increased reliability of detection
Sensing chamber keeps out dust and other airborne contaminants
Operates over a broad range of voltages at extremes of temperature
CONTACT AMPAC
8.5 to 33 VDC
65μA at 24 VDC
40mA at 24 VDC
1.2kΩ to -ve supply
97Dia x 42H mm
-40°C to +70°C (no icing)
0 to 98% (non condensing)
IP23D (EN60529)
80 grams
Orbis Multisensor Detector (AS)
Approvals: AS7240.7/CSIRO
AUS / PAGE 61
Operating voltage
Quiescent current
Alarm current
Remote output
Size
Operating temperature
Relative humidity
IP rating
Weight
HOME
CONTENTS
SEARCH
ZOOM
201-0514
PRINT
EXIT
DETECTORS
ORBIS Conventional
Orbis Heat Detector
The Orbis Heat Detector monitors temperature by using a single
thermistor network which provides a voltage output proportional to the
external air temperature. There are seven classes of heat detectors in the
Orbis range designed to suit a wide variety of operating conditions.
•
•
•
•
Can be used for applications where smoke detectors are unsuitable
Ideal in environments that are dirty or smoky under normal conditions
Reduced incidence of false alarms
Increased reliability of detection
Operating voltage
Quiescent current
Alarm current
Remote output
Size
Operating temperature
Relative humidity
IP rating
Weight
8.5 to 33 VDC
65μA at 24 VDC
40mA at 24 VDC
1.2kΩ to -ve supply
97Dia x 36H mm
-40°C to +70°C (no icing)
0 to 98% (non condensing)
IP23D (EN60529)
70 grams
Orbis Heat Detector
Orbis BR (65°C) Heat Detector (Type A) Rate of Rise (AS)
Orbis A2S (50°C) Heat Detector (Type B) Static (AS)
Orbis CR (80°C) Heat Detector (Type C) Rate of Rise (AS)
Orbis CS (80°C) Heat Detector (Type D) Static (AS)
Approvals: AS7240.5/CSIRO
201-0500
201-0504
201-0508
201-0510
Orbis TimeSaver Base
The TimeSaver Base is a completely new design that provides installers
with an open working area with fixing holes shaped to allow a simple
mounting procedure.
•
•
•
•
•
•
Grouped terminals to make wiring easy
Two fixing centres
LED alignment mark
Cable stripping guide
Detector locking mechanism
Continuity link for voltage testing prior to testing
100Dia x 8H mm
IP23D (EN60529)
60 grams
Size
IP rating
Weight
Orbis TimeSaver Standard Base
Orbis Time Saver LX Base
Orbis TimeSaver Diode Base Diode version available, which has a diode fitted for systems that house
active EOL monitoring for head removal.
Simplified (LX version) available without the continuit link fitted.
AUS / PAGE 62
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
201-0540
201-0541
201-0542
DETECTORS
ORBIS Conventional
Orbis LX Base
The Orbis LX Base has two slots for fixing screws at a spacing of 51mm
to 69mm. Detectors fit into the base one way only and require clockwise
rotation without force to be plugged in.
• One way fit
• Detector locking mechanism
Size
Operating temperature
Humidity
IP rating
Weight
100Dia x 8H mm
-40°C to +70°C
0 to 98%
IP23D (EN60529)
60 grams
Orbis LX Base
201-0545
Orbis TimeSaver Relay Base
The TimeSaver Relay Base incorporates a single pole voltage-free changeover contact for switching external equipment. When the detector changes
to the alarm state, the relay is energised, causing the contact to change
state. The contact will remain in this condition until the detector is reset.
•
•
•
•
•
•
•
Grouped terminals to make wiring easy
Two fixing centres
LED alignment mark
Cable stripping guide
Continuity link for voltage testing of zone wiring prior to commissioning
Detector locking mechanism
Capable of switching up to 30V at 1A
Size
Operating temperature
Humidity
IP rating
Weight
100Dia x 8H mm
-40°C to +70°C
0 to 98%
IP23D (EN60529)
60 grams
Orbis TimeSaver Relay Base
201-0543
Approvals: AS7240/CSIRO
AUS / PAGE 63
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
DETECTORS
ORBIS Conventional
Ampac Duct Sampling Unit
The Ampac Duct Sampling Unit is designed to monitor levels of smoke in
air ducts operating in air speeds of 0.5 to 20 meters per second.
The duct smoke detector can be fitted to any wall of a ventilation duct
and has two tubes that extend into the duct through punched holes.
The perforated sampling tube is placed in the airflow upstream of the
exhaust tube which causes a pressure differential in the duct detector. Air
is sucked up the sampling tube, across the detector and exhausted back
into the air duct.
• T he cover of the duct smoke detector is monitored to ensure working
integrity and if removed, causes a fault to appear at the fire alarm
control panel
• Easily accessible wire clamping terminals ensure secure and fast
termination
• Clear cover hence the alarm LED on the detector is visible at all times
• Unique self-sealing test port allows the dispensing of test smoke via a
needle into the duct smoke detector to be tested without the need to
remove the cover
• Sampling pipes available in 4 lengths
• Weather resistant enclosure
Approvals: C-tick, AS1603-13
Using the 360mm sampling pipe supplied, an air duct of up to 560mm
can be monitored. For duct widths greater than 560mm, three other
lengths of sampling pipe are available:
1. For duct width 300 to 750mm
2. For duct width 750 to 1500mm
3. For duct width 1500 to 3000mm
Housing
Cover
Dimension
Temperature Range
Humidity
Weight
Grey - ABS
Transparent - ABS
115H x 340W x 60D mm
0 to +60°C
Up to 85%, no condensation
5.5 kg
Orbis Duct Sampling Unit inc Detector Base
Duct Probe 300 to 750mm Sampling Pipe
Duct Probe 750 to 1500mm Sampling Pipe
Duct Probe 1500 to 3000mm Sampling Pipe
Orbis Photo Optical Head
214-0052
214-0060
214-0061
214-0062
201-0512
Note: The detector head is sold separately to the duct sampling unit
• V
olt free normally opened or closed non-latching relay contact. Relay
energises when detector is in alarm (Available only with Ampac Orbis
option)
• Both sampling and exhaust pipes are fitted to the back box without
the need for tools making installation easier
AUS / PAGE 64
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
DETECTORS
XP95
Intelligent Detectors
The XP95 range of intelligent fire detectors is advanced in design, improved in performance
and has unique features that benefit the installer and end user. The range features smoke
detectors (ionisation and optical), standard and high temperature heat detectors and a
multisensor. Beam detectors, flame detectors, manual call points, audio visual signalling
devices, interface units and isolators complete the range. XP95 has a ‘central intelligence’
system where all the decisions are made by the control panel.
Features
• Alarm Flag for fast alarm reporting
• Alarm Address for fast location of alarm
• XPERT card addressing
• Electronics-free base
• Easy installation
• Elegant design
• Insect Resistant
AUS / PAGE 65
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
DETECTORS
XP95 Intelligent
XP95 Ionisation Smoke Detector
The XP95 Ionisation Smoke Detector uses a low activity radioactive foil
to detect fires by irradiating the air in the smoke chambers and causing
a current flow. If smoke enters the chamber, the current flow is reduced
leading to an alarm.
•
•
•
•
Responds well to fast-burning, flaming fires
Designed to operate in a variety of environments
Minimal effects from temperature, humidity, atmospheric pressure
Well protected against electromagnetic interference over a wide frequency range
Voltage
Quiescent current
Alarm current
Size inc base
Operating temperature
Relative humidity
IP rating
Weight inc base
17-28 VDC
280μA at 24 VDC
2.0mA at 24 VDC
100Dia x 50H mm
-20°C to +60°C (no icing)
0 to 95% (non condensing)
IP23D
161 grams
XP95 Ionisation Smoke Detector Approvals: AS1603.2
201-0002
XP95 Optical Smoke Detector
The XP95 Optical Smoke Detector works using the light scatter principle
and is ideal for applications where slow-burning or smouldering fires are
likely.
• Responds well to slow-burning, smouldering fires
• Well suited for bedrooms and escape routes
• Unaffected by wind or atmospheric pressure
Approvals: AS1603.2
Voltage
17-28 VDC
Quiescent current
340μA at 24 VDC
Alarm current
4mA at 24 VDC
Size inc base
100Dia x 50H mm
-20°C to +60°C (no icing)
Operating temperature
Relative humidity
0 to 95% (non condensing)
IP rating
IP23D
Weight inc base
157 grams
Sensitivity0.12db/m
XP95 Optical Smoke Detector XP95 Optical Smoke (Black) Detector
AUS / PAGE 66
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
201-0003
201-0092
EXIT
DETECTORS
XP95 Intelligent
XP95 Heat Detector
The XP95 Heat Detector monitors temperature by using a single
thermistor network which provides a count output proportional to the
external air temperature. The XP95 range features two Heat Detectors,
standard and high emperature. The standard heat detector is classified
as an A2S device and will report an alarm at 55°C. The high temperature
detector, classified as a CS device, will report an alarm at 90°C.
• Ideal in environments that are dirty or smokey under normal conditions
• Well suited for warehouses, loading bays and car parks
• Unaffected by wind or atmospheric pressure
Approvals: AS1603.1
Voltage
Quiescent current
Alarm current
Size inc base
Operating temperature
Relative humidity
IP rating
Weight inc base
17-28 VDC
250-270μA at 24 VDC
2mA at 24 VDC
100Dia x 50H mm
A2S: -20°C to +70°C (no icing)
CS: -20°C to +120°C (no icing)
0 to 95% (non condensing)
IP53
157 grams
XP95 Heat Detector
XP95 Heat Detector (Type A & B) A2S (55°C)
201-0001
XP95 Intelligent Detector Base
All detectors in the XP95 range fit the Intelligent Detector Base. It is a low
insertion force base with stainless steel contacts for the detector terminals.
• XPERT addressing
• One way fit of detector
• Locking feature to prevent unauthorised removal
CONTACT AMPAC
HOME
100Dia x 8H mm
-20°C to +60°C (no icing)
0 to 95% (non condensing)
55 grams
XP95/ Discovery Detector Base with Xpert Card
XP95 Detector Base (Black) with Xpert Card
Approvals: AS1603:Pt1&2
AUS / PAGE 67
Size
Operating temperature
Relative humidity
Weight
CONTENTS
SEARCH
ZOOM
PRINT
201-0004
201-0093
EXIT
DETECTORS
XP95 Intelligent
XP95 Isolating Base
The new style Isolating Base senses and detects short-circuit faults on
XP95 loops and spurs.
• Up to 20 devices may be installed between isolating bases
• High brightness LED
Voltage
Quiescent current
Size
Operating temperature
Relative humidity
Weight
17-28 VDC
47μA (non isolating)
4mA (isolating)
100Dia x 24H mm
-20°C to +60°C (no icing)
0 to 95% (non condensing)
100 grams
XP95/ Discovery Isolating Base with Xpert Card
Blank XPERT Card
Pre-addressed XPERT Card
A universal address card supplied with all bases. Using a coding guide, pips
are removed to set the address of the inserted detector.
Pre-addressed XPERT cards are supplied with pips already removed.
•
•
•
•
AUS / PAGE 68
201-0125
Simplifies and speeds up installation and commissioning
Uses patented, proven technology
Address remains the same, no matter how often detectors are replaced
Flexibility to create any address
CONTACT AMPAC
HOME
CONTENTS
• Saves time and increases accuracy during commissioning
• Pre-numbered 1-126
Blank XPERT Card
Pre-addressed (1-126) Xpert Cards
SEARCH
ZOOM
38531-771
201-0013
PRINT
EXIT
DETECTORS
XP95 Intelligent
Ampac Duct Sampling Unit
The Ampac Duct Sampling Unit is designed to monitor levels of smoke in
air ducts operating in air speeds of 0.5 to 20 meters per second.
The duct smoke detector can be fitted to any wall of a ventilation duct
and has two tubes that extend into the duct through punched holes.
The perforated sampling tube is placed in the airflow upstream of the
exhaust tube which causes a pressure differential in the duct detector. Air
is sucked up the sampling tube, across the detector and exhausted back
into the air duct.
• E asily accessible wire clamping terminals ensure secure and fast
termination
• Clear cover hence the alarm LED on the detector is visible at all times
• Unique self-sealing test port allows the dispensing of test smoke via a
needle into the duct smoke detector to be tested without the need to
remove the cover
• Sampling pipes available in 4 lengths
• Weather resistant enclosure
Approvals: C-tick, AS1603-13
Housing
Cover
Dimension
Temperature Range
Humidity
Weight
Using the 360mm sampling pipe supplied, an air duct of up to 560mm
can be monitored. For duct widths greater than 560mm, three other
lengths of sampling pipe are available:
1. For duct width 300mm to 750mm
2. For duct width 750mm to 1500mm
3. For duct width 1500mm to 3000mm
Grey - ABS
Transparent - ABS
115H x 340W x 60D mm
0 to +60°C
Up to 85%, no condensation
5.5 kg
Duct Sampling Unit inc XP95 Detector Base
Duct Probe 300mm to 750mm Sampling Pipe
Duct Probe 750mm to 1500mm Sampling Pipe
Duct Probe 1500mm to 3000mm Sampling Pipe
XP95 Optical Smoke Detector
Discovery Multisensor Detector
214-0051
214-0060
214-0061
214-0062
201-0003
201-0094
Note: The detector is sold separately to the duct sampling unit
• B
oth sampling and exhaust pipes are fitted to the back box without
the need for tools making installation easier
• The cover of the duct smoke detector is monitored to ensure working
integrity and if removed, causes a fault to appear at the fire alarm
control panel
AUS / PAGE 69
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
DETECTORS
Discovery
Intelligent Detectors
Discovery is a range of high-specification, intelligent fire detectors developed to meet
the requirements of sophisticated systems while providing engineers with an additional
dimension in fire protection capability. Discovery has a ‘distributed intelligence system’
where decisions are made in the detector head as well as at the control panel. Drift
compensation is also incorporated into the detector, allowing it to adapt to dirty or dusty
environments reducing false alarms.
• Rejection of transient signals
• Flashing LED option
• Five response modes for ease of optimisation to changing environments
• Drift compensation to ensure constant sensitivity
• Four bytes of non-volatile memory for user data
• Alarm flag for fast alarm reporting
• Conventional alarm facility during control panel processor fault
• 360° visibility in alarm
• Compatible with XP95 systems
• Insect resistant
AUS / PAGE 70
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
DETECTORS
APOLLO DISCOVERY Intelligent
Discovery Heat Detector
The Discovery Heat Detector, distinguishable by the low airflow resistant
case, uses a single thermistor to sense the air temperature around the
detector.
•
•
•
•
Ideal in environments that are dirty or smokey under normal conditions
Well suited for warehouses, loading bays and car parks
Unaffected by wind or atmospheric pressure
Remote test feature
CONTACT AMPAC
17-28 VDC
500μA at 24 VDC
3.4mA at 24 VDC
100Dia x 50H mm
0°C to +80°C (no icing)
0 to 95% (non condensing)
IP53
160 grams
Discovery Heat Detector
Discovery Heat Detector Type D
Discovery Heat Detector Type C
Approvals: AS1603.1
AUS / PAGE 71
Voltage
Quiescent current
Alarm current
Size inc base
Operating temperature
Relative humidity
IP rating
Weight inc base
HOME
CONTENTS
SEARCH
ZOOM
PRINT
201-0090
201-0089
EXIT
DETECTORS
APOLLO DISCOVERY Intelligent
Discovery Multisensor Detector
The Discovery Multisensor Detector comprises optical smoke and
thermistor temperature sensors whose respective outputs can be split
to deliver specific smoke or thermal actions respectively. This capability
can aid early Alarm warning routines and other advanced detection
techniques.
•
•
•
•
•
•
•
Ideal for a wide range of applications
Highly immune to false alarms
Well suited for environments such as hotel bedrooms
Unaffected by wind or atmospheric pressure
Well suited for sensitive environments
Heat only, optical only options
Remote test feature
Voltage
Quiescent current
Alarm current
Size inc base
Operating temperature
Relative humidity
IP rating
Weight inc base
17-28 VDC
500μA at 24 VDC
3.5mA at 24 VDC
100Dia x 58H mm
-20°C to +60°C (no icing)
0 to 95% (non condensing)
IP43
160 grams
Discovery Multisensor Detector
201-0094
Approvals: AS1603.1
Multisensor
Detector
Operating
Modes
AUS / PAGE 72
CONTACT AMPAC
Mode
Smoke Sensitivity
(grey smoke)
1
2
3
4
5
HOME
% per m % per ft
1.1 0.35
2.1
0.7
2.80.9
4.21.4
No response to smoke
CONTENTS
Temperature Sensitivity
Response Type
(relative)
High
No response to heat
Low
High
See text
SEARCH
Minimum Time to
Alarm (seconds)
Multisensor
Optical
Multisensor
Multisensor
Heat A1
ZOOM
PRINT
20
30
20
20
30
EXIT
DETECTORS
APOLLO DISCOVERY Intelligent
Discovery Carbon Monoxide Detector
The Discovery Carbon Monoxide (CO) Detector is good at detecting deepseated fires. Please note that CO detectors do not detect smoke particles
or heat and are not universal replacements for smoke detectors.
•
•
•
•
•
Enhanced detection capability
Early response to hot fires
Ideal for smouldering fires
Less susceptible to false alarms caused by steam than smoke alarms
Five response modes
Voltage
Quiescent current
Alarm current
Size inc base
Operating temperature
Relative humidity
IP rating
Weight inc base
Cell life (max)
Discovery Carbon Monoxide Detector
Approvals: AS1603.14
Mode
Relative
Performance of
Detectors in
Test Fires
AUS / PAGE 73
CONTACT AMPAC
17-28 VDC
500μA at 24 VDC
3.5mA at 24 VDC
100Dia x 50H mm
0°C to +50°C (no icing)
15 to 95% (non condensing)
IP43
160 grams
7 years
Alarm Threshold
(ppm)
Minimum Time to Alarm
(seconds)
30
60
1
201-0102
Typical Application
Sleeping with no ambient CO
2
45
30
General use fast response such as supplementary protection in atria
3
45
60
General use and sleeping risk with some low-level CO (such as from light smoking or an unventilated gas fire)
4
60
30
General smoking area and supplementary detection of deep seated fires such as laundry rooms
Supplementary use in kitchen or boiler room
5
75
HOME
30
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
DETECTORS
APOLLO DISCOVERY Intelligent
Discovery Intelligent Detector Base
All detectors in the Discovery range fit the Intelligent Detector Base. It is
a low insertion force base with stainless steel contacts for the detector
terminals. XPERT cards are supplied with all bases.
• XPERT addressing
• One way fit
• Locking feature to prevent unauthorised removal
Size
Operating temperature
Relative humidity
Weight
100Dia x 8H mm
-20°C to +60°C (no icing)
0 to 95% (non condensing)
55 grams
XP95/Discovery Detector Base with Xpert Card
201-0004
Approvals: AS1603.1&2
Discovery Isolating Base
The new style Isolating Base senses and detects short-circuit faults on
loops and spurs.
• Up to 20 devices may be installed between isolating bases
• High brightness LED
Voltage
Quiescent current
Size
Operating temperature
Relative humidity
Weight
17-28 VDC
47μA (non isolating)
4mA (isolating)
100Dia x 24H mm
-20°C to +60°C (no icing)
0 to 95% (non condensing)
100 grams
XP95/Discovery Isolating Base with Xpert Card
Blank XPERT Card
Pre-addressed XPERT Card
A universal address card supplied with all bases. Using a coding guide, pips
are removed to set the address of the inserted detector.
Pre-addressed XPERT cards are supplied with PIPs already removed.
•
•
•
•
AUS / PAGE 74
201-0125
Simplifies and speeds up installation and commissioning
Uses patented, proven technology
Address remains the same, no matter how often detectors are replaced
Flexibility to create any address
CONTACT AMPAC
HOME
CONTENTS
• Saves time and increases accuracy during commissioning
• Pre-numbered 1-126
Blank XPERT Card
Pre-addressed (1-126) Xpert Cards
SEARCH
ZOOM
38531-771
201-0013
PRINT
EXIT
DETECTORS
BEAM DETECTORS Conventional
FIRERAY 2000 Optical Beam Smoke Detector
The FIRERAY 2000 is a conventional infrared optical beam smoke detector.
It is an End to End type beam detector and is thus less susceptible to stray
reflections since any reflection goes back towards the transmitter. As a
result projected Optical Beams can operate within narrower gaps than
reflective types.
•
•
•
•
•
•
•
Separate transmitter and receiver
Range 10 to 100 metres
Low current consumption
Automatic drift compemsation
3 x selectable sensitivity threshold levels
Low level control unit
Optional electronic alignment tool
Operating range
10-100 metres
Operating voltage
10.2VDC to 30VDC
Fire relay contactsNorm open volt free 2A @ 30VDC
Resistive
Fault relay contactsNorm closed volt free 2A @ 30VDC
Resistive
ConditionAlarm condition: fire relay closing
May be latching or non-latching
Operating temperature
-20°C to +55°C (no icing)
Relative humidity
0-90% (non condensing)
IP rating
IP50
FIRERAY 2000 Beam Detector
Approvals: AS1603-7, EN54-12 and UL268
AUS / PAGE 75
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
220-0004
DETECTORS
BEAM DETECTORS Conventional
FIRERAY 5000 Motorised Beam System
The FIRERAY 5000 Optical Beam Smoke Detectors can be used to provide
‘wide area’ smoke detection. They are usually used in situations where
it is impractical, inappropriate or not cost effective (installation, wiring
and maintenance) to use traditional point-type detectors. It also enables
coverage of a large area, at minimal cost. Optical beam smoke detectors
are also ideally suited for situations that might include high ceilings, dusty
and dirty environments, or environments that experience temperature
extremes.
•
•
•
•
•
•
•
Up to 4 optical beam detectors per system controller
Easy fit system
Ground level control
Laser assisted alignment
Auto-optimise beam alignment
Contamination compensation
Building shift compensation
Operating distance (separation)
Cable length – system controller to detector
(2 core screened fire resistant)
Operating voltage (to system controller)
Operating temperature
Relative humidity
IP rating
8-100 metres
100 metres
14VDC to 28VDC
-10°C to +55°C (no icing)
93% (non condensing)
IP54
FIRERAY 5000 Motorised Beam System
System Controller, Detector and Reflector
Additional Detector and Reflector
220-0008
220-0009
Approvals: AS7240-12, EN54-12 and UL268
Accessories for FIRERAY 50R/100R AWD 5000
An extensive range of accessories are available to compliment the FIRERAY
product.
Accessories for FIRERAY 50R/ 100R AWD 5000
Single Reflector <50m
3 x Reflector Long Range 100m Kit
Universal Bracket
1 Prism Plate
4 Prism Plate
Universal Ceiling Mount
AUS / PAGE 76
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
220-0007
220-0010
220-0011
220-0012
220-0013
220-0014
EXIT
INTERFACES
XP95/Discovery
Intelligent Interfaces
Apollo manufactures a comprehensive range of interfaces for intelligent systems which
enable fire protection systems to be engineered simply and effectively without the
need for custom-designed equipment. There are a variety of interfaces available to suit
a number of individual applications.
Standard Interfaces with Isolators are fitted with bi-directional short-circuit isolators
so that they are unaffected by a single short circuit on either loop input or output.
However, the Input/Output Unit and Output Unit with isolator are exceptions to this.
The removal of loop power to these interfaces will cause a ‘set’ relay to ‘reset’.
DIN-Rail Interfaces feature enclosures that clip to standard 35mm DIN-Rails or are
screwed to the base of a larger enclosure. They enable fire system designers to
determine the functions required and create multi-purpose interfaces for individual
sites.
Optimum protection can be provided when using the built-in isolator models.
• Easy to install
• Well protected
• Modular design
• A neat solution
AUS / PAGE 77
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
INTERFACES
AMPAC INPUT/OUTPUT DEVICES Intelligent
Single Input Device (SID)
The Single Input Device is an addressable loop device for use on the
Apollo XP95 or Discovery protocol and provides a single monitored
input.
•Interfaces a switch input to an Apollo addressable loop
• Loop powered
• One monitored input
• Only one address used
• Enclosure or DIN-Rail chassis mount
• Status indicators can be switched on and off
Voltage
Quiescent current
Max current
Monitored input
Size – enclosure
Size – DIN chassis
Operating temperature
Humidity
IP rating – enclosure
Weight – enclosure
Weight – DIN chassis
17-28 VDC
1.82mA at 24 VDC
2.37mA at 24 VDC
20k normal 500 - 15k closed
132H x 82W x 55D mm
77H x 57W x 40D mm
-20°C to +60°C (no icing)
0 to 95% relative humidity
IP55
155 grams
75 grams
Single Input Device (SID) – Boxed
Single Input Device (SID) – DIN mount
201-0300
201-0350
Single Input/Output Device (SIOD)
The Single Input/Output Device is an addressable loop device for use on
the Apollo XP95 or Discovery protocol and provides a single monitored
input and a voltage free relay output.
•Interfaces a switch input and a relay output to addressable loop
• Loop powered
• One monitored input
• Single relay with clean changeover contact
• Only one address used
• Enclosure or DIN-Rail chassis mount
• Status indicators can be switched on and off
Voltage
Quiescent current
Max current
Relay contact rating
Monitored input
Size – enclosure
Size – DIN chassis
Operating temperature
Humidity
IP rating – enclosure
Weight – enclosure
Weight – DIN chassis
17-28 VDC
1.74mA at 24 VDC
6.84mA at 24 VDC
1A at 24 VDC clean changeover
20k normal 500 - 15k closed
132H x 82W x 55D mm
77H x 57W x 40D mm
-20°C to +60°C (no icing)
0 to 95% relative humidity
IP55
155 grams
75 grams
Single Input/Output Device (SIOD) – Boxed
Single Input/Output Device (SIOD) – DIN mount
AUS / PAGE 78
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
201-0301
201-0351
EXIT
INTERFACES
AMPAC INPUT/OUTPUT DEVICES Intelligent
Three Input Device (3ID)
The Three Input Device is a versatile loop-powered three monitored input
unit device for use on the Apollo XP95 or Discovery protocol.
•Interfaces three switch inputs to addressable loop
• Loop powered
• Three monitored inputs
• Only one address used
• Enclosure or DIN-Rail chassis mount
• Status indicators can be switched on and off
Voltage
Quiescent current
Max current
Monitored input
Size – enclosure
Size – DIN chassis
Operating temperature
Humidity
IP rating – enclosure
Weight – enclosure
Weight – DIN chassis
17-28 VDC
1.45mA at 24 VDC
3.54mA at 24 VDC
20k normal 500 - 15k closed
200H x 150W x 60D mm
98H x 72W x 40D mm
-20°C to +60°C (no icing)
0 to 95% relative humidity
IP41
500 grams
125 grams
Three Input Device (3ID) – Boxed
Three Input Device (3ID) – DIN mount
201-0308
201-0358
Three Input/Output Device (3IOD)
The Three Input/Output Device is a versatile loop-powered unit for use
on the Apollo XP95 or Discovery protocol. It provides three monitored
inputs and three voltage free relay outputs.
•Interfaces three switch inputs and three relay outputs to
addressable loop
• Loop powered
• Three fault monitored input
• Three relays with clean changeover contact
• Only one address used
• Enclosure or DIN-Rail chassis mount
• Status indicators can be switched on and off
Voltage
Quiescent current
Max current
Relay contact rating
Monitored input
Size – enclosure
Size – DIN chassis
Operating temperature
Humidity
IP rating – enclosure
Weight – enclosure
Weight – DIN chassis
17-28 VDC
2.06mA at 24 VDC
19.23mA at 24 VDC
1A at 24 VDC clean changeover
20k normal 500 - 15k closed
200H x 150W x 60D mm
98H x 72W x 40D mm
-20°C to +60°C (no icing)
0 to 95% relative humidity
IP41
500 grams
125 grams
Three Input/Output Device (3IOD) – Boxed
Three Input/Output Device (3IOD) – DIN mount
AUS / PAGE 79
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
201-0309
201-0359
EXIT
INTERFACES
AMPAC INPUT/OUTPUT DEVICES Intelligent
Three Input/Output Device (3IOD) EP – Externally Powered
The Three Input/Output Device EP is an externally powered unit device
for use on the Apollo XP95 or Discovery protocol. Using an external
24VDC power supply, each device draws a minimum amount of loop
current and provides three monitored inputs and three voltage free relay
outputs.
•Interfaces three switch inputs and three relay outputs to
addressable loop
• Externally powered
• Three fault monitored input
• Three relays with clean changeover contact
• Only one address used
• Enclosure or DIN-Rail chassis mount
• Status indicators can be switched on or off
Voltage
Quiescent current – loop
Quiescent current – external
Max current – loop
Max current – external
Relay contact rating
Monitored input
Size – enclosure
Size – DIN chassis
Operating temperature
Humidity
IP rating – enclosure
Weight – enclosure
Weight – DIN chassis
17-28 VDC
1.51mA at 24 VDC
5.08mA at 24 VDC
7.20mA at 24 VDC
19.55mA at 24 VDC
1A at 24 VDC clean changeover
20k normal 500 - 15k closed
200H x 150W x 60D mm
98H x 72W x 40D mm
-20°C to +60°C (no icing)
0 to 95% relative humidity
IP41
500 grams
125 grams
Three Input/Output Device (3IOD) EP – Boxed
Three Input/Output Device (3IOD) EP – DIN mount
201-0310
201-0360
Alarm Acknowledgement Facility
The Alarm Acknowledgment Facility (AAF) is a loop powered addressable
device that helps reduce the costly consequence of an unwanted alarm.
•
•
•
•
•
•
•
•
•
•
L oop Powered Addressable Device
B
uilt in Short Circuit Isolator
E asy configuration of Acknowledge and Investigate periods
E vent logging of AAF sequence
A
llows a group of detectors to be assigned to a nominated AAF
esthetically pleasing single gang Clipsal 2000 wall plate
A
Investigate status displayed at FACP and all associated LCDA’s
udible warning is 75dB @ 1m from the built in buzzer
A
n board visual indication for “polling”, Fire and Fault status
O
emote ‘Hush’ button input terminals available
R
Operating Voltage
Quiescent Current
Alarm Current
Address Setting
Dimension
Material
Weight
21 to 28 VDC (loop powered)
900μA at 24VDC
<8mA at 24VDC
1 to 126
Single gang Clipsal plate
High impact ABS (white)
45 grams
Alarm Acknowledgement Facility – Vertical
Alarm Acknowledgement Facility – Horizontal
226-0002
226-0004
Approvals: AS7240 and AS4428
AUS / PAGE 80
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
INTERFACES
AMPAC INPUT/OUTPUT DEVICES Intelligent
Loop Powered Zone Interface Device (LZID)
AMPAC’s Loop Powered Zone Interface Device (LZID) is designed to
connect to the analogue loops in any of AMPAC’s addressable range of fire
alarm control panels (FACP’s).
•
•
•
•
•
•
S ingle Conventional Zone Input
A
pollo XP95 & Discovery protocol
S upports up to 40 conventional detectors
R
emote LED Output
S hort Circuit Isolation
P
rogrammable EOL (3K3Ω, 6K2Ω or 10uF)
Operating Voltage
Zone Voltage (Loop Voltage ≥21V)
End Of Line Values
Quiescent Current (EOL Fitted, Zone
oltage = 22V and no detector load
Alarm Current (remote LED not fitted)
Alarm Current (remote LED fitted)
No LZID’s / Loop
No. Detectors / Zone
Operating temperature
Dimensions
DIN Mount
Enclosed / Boxed
Weight
DIN Mount
Enclosed / Boxed
16Vdc – 27Vdc
17 – 22Vdc
3K3Ω
6K2Ω
12mA
9mA
6mA
28.5mA
28.5mA 28.5mA
32mA
32mA 32mA
12 x 250mA Loop
24 x 500mA Loop
40 Max
0°C to +70°C
98 (L) x 72.5 (W) x 40mm (D)
200 (L) x 150 (W) x 60mm (D)
140g
460g
Loop Powered ZID (DIN Mount)
Loop Powered ZID (Enclosed)
AUS / PAGE 81
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
10uF
4210-0004
4210-0005
PRINT
EXIT
INTERFACES
XP95/DISCOVERY Intelligent
Input/Output Unit with Isolator
The Input/Output unit with Isolator provides a voltage free, single, pole,
change-over relay output, a single, monitored switch input and an
unmonitored, non-polarised opto-coupled input.
•
•
•
•
•
•
It can report fault, switch open and switch closed levels
Three visible LEDs
Loop powered
Voltage free
Capable of switching up to 1A at 30V
Built-in short circuit isolator (fitted on 55000-847)
Approvals: AS4428.1
Voltage17-28vdc
1.2mA at 24vdc
Quiescent current
3.5mA at 24vdc
Max current
Relay contact
1A at 30vdc
Opto input
35vdc max
Monitored input voltage
9-11vdc
-20°C to +70°C (no icing)
Operating temperature
0 to 95% (non condensing)
Relative humidity
IP Rating
IP54
Size
150W x 90H x 48D mm
Weight
240 grams
Input Unit with Isolator
Input Unit (no Isolator)
Output Unit with Isolator
Output Unit (no Isolator)
201-0151
201-0007
201-0152
201-0008
Zone Monitor with Isolator
The Zone Monitor with Isolator powers and controls the operation of a
zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery
or XP95 Loop.
• Loop powered
• Visible LED
• Built-in short circuit isolator (fitted on 55000-845)
Approvals: AS4428.1
Voltage17-28vdc
4mA + detector load
Quiescent current
Alarm current
11mA at 24vdc
EOL resistor value
5.1k ¹⁄₃ watt
50µF
Maximum capacitor on zone terminals
Zone voltage
19V ± 1V
-20°C to +70°C (no icing)
Operating temperature
Relative humidity
0 to 95% (non condensing)
IP Rating
IP54
Size
150W x 90H x 48D mm
Weight
230 grams
Discovery/XP95 Zone Monitor with Isolator
Discovery/XP95 Zone Monitor (no Isolator)
AUS / PAGE 82
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
201-0126
201-0012
EXIT
INTERFACES
XP95/DISCOVERY Intelligent
Sounder Control Unit with Isolator
The XP95 Sounder Control Unit with Isolator is used to control the
operation of a zone of conventional sounders and report their status to
the control panel.
• Allows sounders to be operated continuously or be pulsed, 1 second on 1 second off
• May be synchronized when in pulsed operation
Approvals: AS4428.1
Voltage17-28vdc
1.95mA at 24vdc
Quiescent current
4.5mA
Loop current max
External supply
9-32vdc 1.25A
3mA at 32vdc
External quiescent current
47mA + load
External current max
1A at 30vdc
Sounder circuit load max
-20°C to +70°C (no icing)
Operating temperature
0 to 95% (non condensing)
Relative humidity
IP54
IP Rating
Size
150W x 90H x 48D mm
240 grams
Weight
Sounder Control Unit with Isolator
Sounder Control Unit (no Isolator)
201-0127
201-0010
Three Channel Input/Output Unit with Isolator
The Three Channel Input/Output unit with Isolator provides three voltage
free, single pole, change-over relay outputs, and three monitored switch
inputs.
•
•
•
•
Supervises one or more normally-open switches on each of
the three inputs
Loop powered
Capable of switching up to 30V at 1A on each of the three outputs
Built-in short circuit isolator
Approvals: AS4428.1
AUS / PAGE 83
CONTACT AMPAC
Voltage17-28vdc
Quiescent current
3mA at 24vdc
Max current
7.5mA at 24vdc
Relay contact
1A at 30vdc
Monitored input voltage
9-11vdc
Operating temperature
-20°C to +70°C (no icing)
Relative humidity
0 to 95% (non condensing)
IP Rating
IP54
Size
250W x 175H x 75D mm
Weight
621 grams
Three Channel Input/Output Unit with Isolator
Three Channel Input/Output Unit (no Isolator)
HOME
CONTENTS
SEARCH
ZOOM
PRINT
201-0175
201-0115
EXIT
INTERFACES
XP95/DISCOVERY Intelligent
Mains Switching Input/Output Unit
The XP95 Loop Powered Mains Switching Input/ Output Unit provides a
voltage free, single pole charge- over relay output and a monitored switch
input.
• Voltage free single pole charge-over relay
• Monitored switch input
• Fault LED
• Input active LED
• Relay on LED
Voltage17-28vdc
Quiescent current
1.2mA at 24vdc
Max current
2.5mA at 24vdc
Relay contact
Switching capacity
1.25kVA
Monitored input voltage
9-11vdc
Operating temperature
-20°C to +70°C (no icing)
Relative humidity
0 to 95% (non condensing)
IP Rating
IP54
Size
150W x 90H x 48D mm
Weight
240 grams
Mains Switching Input/Output Unit
AUS / PAGE 84
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
201-0180
PRINT
EXIT
AUDIO VISUAL SIGNALLING
Audio Visual
Signalling
Ampac offers a wide range of Intelligent Audio Visual (AV) signalling devices for use in
conjunction with its range of intelligent and conventional detectors and control panels.
A versatile and functional range offering a huge choice for any application.
• Sounder Bases combine an alarm sounder and detector base
• Beacon Bases combine an alarm beacon and detector base
•Sounder Beacon Bases combine an alarm sounder, beacon and detector base
• Sounders are used to provide an audible indication of an alarm
• Beacons are used to provide an visual flashing indication of an alarm
•Sounder/Beacons are used to provide an audible and flashing indication of an alarm
AUS / PAGE 85
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
AUDIO VISUAL SIGNALLING
XP95/DISCOVERY INTELLIGENT SOUNDER BASES
Integrated Sounder Base
The Integrated Sounder Base comprises a base sounder with integral
mounting base and is for use with Discovery or XP95 ranges. It is
designed for indoor use.
•
•
•
•
•
•
Two volume ranges – via DIP switch setting
Synchronisation of ‘alert’ and ‘evacuate’ tones
Individual and group addressing
Unique acoustic self-test
Integrated base
Built-In short circuit isolator
CONTACT AMPAC
HOME
17-28 VDC
1.2mA
5mA
92dB(A)
-20°C to +60°C (no icing)
0 to 95% (non condensing)
IP21D
115Dia x 38H mm
140 grams
Integrated Base Sounder
White Cap
Approvals: AS1670.4
AUS / PAGE 86
Voltage (polarity sensitive)
Quiescent current
Max current (sounder operated)
Max sounder output
Operating temperature
Relative humidity
IP rating
Size
Weight
CONTENTS
SEARCH
ZOOM
201-0110
201-0114
PRINT
EXIT
AUDIO VISUAL SIGNALLING
XP95/DISCOVERY INTELLIGENT SOUNDER BEACON BASES
Sounder Beacon Base
The Sounder Beacon Base is a loop-powered sounder and beacon
combined with a standard Intelligent Mounting Base. It is used to signal a
fire alarm in enclosed areas. The Sounder Beacon Base can be used either
with a detector fitted or with a cap for operation as a stand-alone alarm
device.
•
•
•
•
•
•
•
•
•
Two volume ranges via DIP switch
Beacon flash rate as per AS1670.4
Synchronisation of ‘alert’ and ‘evacuate’ tones
Synchronisation of beacon flash
Individual and group addressing
Unique acoustic and beacon self test
Enables DDA compliance
Built-In short circuit isolator
Beacon only variant available
Voltage (polarity sensitive)
Quiescent current + Beacon
Max current (sounder operated)
Max current (beacon only)
Max sounder output
Operating temperature
Relative humidity
IP rating
Size
Weight
17-28 VDC
300µA
8mA
3.1 mA
91dB(A)
-20°C to +60°C (no icing)
0 to 95% (non condensing)
IP21D
115Dia x 38H mm
160 grams
Sounder Beacon Base
Beacon Base
White Cap
Approvals: AS1670.4
AUS / PAGE 87
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
201-0116
201-0120
201-0114
AUDIO VISUAL SIGNALLING
XP95/DISCOVERY INTELLIGENT SOUNDERS
NEW
Intelligent Open-Area Sounder (Sonos)
The Intelligent Open-Area Sounder has been designed for use in open
areas and can be connected to any Discovery or XP95 system.
•
•
•
•
•
•
Self-test fault monitoring
Choice of tones
Group addressing and synchronisation of alarm
Weatherproof IP65
Comes with Isolating Base as standard
Loop powered
CONTACT AMPAC
17-28 VDC
333µA
5mA
88-96dB(A) ±3dB(A)
-10°C to +55°C (no icing)
0 to 95% (non condensing)
IP65
104Dia x 95.5H mm
225 grams
Intelligent Open Area Sounder (Red) Sonos
Intelligent Open Area Sounder (White) Sonos
Approvals: LPCB EN54-3/LPCB
AUS / PAGE 88
Voltage (polarity sensitive)
Quiescent current
Max current (sounder operated)
Max sounder output
Operating temperature
Relative humidity
IP rating
Size
Weight
HOME
CONTENTS
SEARCH
ZOOM
PRINT
205-0100
205-0101
EXIT
AUDIO VISUAL SIGNALLING
XP95/DISCOVERY INTELLIGENT BEACONS
Loop-Powered Beacon
The Loop-Powered Beacon is a local-area beacon designed for indoor use.
The beacon has been developed as a supplement to sounders for use in
situations where there is a risk that sounders will not be heard.
•
•
•
•
•
•
•
High intensity LED – more reliable than xenon beacons
Automatic LED check
Lockable
Wide angle of visibility
Enables DDA compliance
Synchronised flash
Can be used with Discovery or XP95
Approvals: AS1670.4
Voltage (polarity sensitive)
Quiescent current
Max current (beacon operated)
Flash rate
Operating temperature
Relative humidity
IP rating
Size
Weight
17-28 VDC
150µA
3mA
1Hz
-20°C to +60°C (no icing)
0 to 95% (non condensing)
IP23D
115Dia x 38H mm
140 grams
Loop-Powered Beacon (Red)
Loop-Powered Beacon (Clear Lens/Red Flash) Standard Flash
Loop-Powered Beacon (Amber) Standard Flash
201-0118
55000-878
55000-879
NEW
Intelligent Open-Area Beacon (Sonos)
The Intelligent Open-Area Beacon has been developed for use in situations
where there is a risk that sounders will not be heard. It is weatherproof and
can be used outside.
•
•
•
•
•
•
Self-test fault monitoring
Weatherproof IP65
Group addressing
Synchronisation of alarm
Comes with Isolating Base as standard
Loop powered
CONTACT AMPAC
HOME
17-28 VDC
333µA
3.1mA
1Hz
-10°C to +55°C (no icing)
0 to 95% (non condensing)
IP65
104Dia x 97.5H mm
205 grams
Intelligent Open Area Beacon (Red) Sonos
Intelligent Open Area Beacon (Clear) Sonos
Approvals: AS1670.4
AUS / PAGE 89
Voltage (polarity sensitive)
Quiescent current
Max current (beacon operated)
Flash rate
Operating temperature
Relative humidity
IP rating
Size
Weight
CONTENTS
SEARCH
ZOOM
PRINT
208-0100
208-0101
EXIT
AUDIO VISUAL SIGNALLING
XP95/DISCOVERY INTELLIGENT SOUNDER/BEACONS
NEW
Intelligent Open-Area Sounder Beacon
The Intelligent Open-Area Sounder Beacon has been designed for use in
open areas and can be connected to any Discovery or XP95 system.
•
•
•
•
•
•
Gives two functions at one point
Self-test fault monitoring
Choice of tones
Group addressing and synchronisation of alarm
Comes with Isolating Base as standard
Loop powered
Approvals: AS1670.4
AUS / PAGE 90
CONTACT AMPAC
Voltage (polarity sensitive)
Quiescent current
Max current (sounder/beacon operated)
Max sounder output
Flash rate
Operating temperature
Relative humidity
IP rating
Size
Weight
17-28 VDC
333µA
8mA
100dB(A)
1Hz
-10°C to +55°C (no icing)
0 to 95% (non condensing)
IP65
104Dia x 97.5H mm
260 grams
Intelligent Open Area Sounder Beacon (Red) Sonos
Intelligent Open Area Sounder Beacon (Clear) Sonos
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
205-0102
205-0103
AUDIO VISUAL SIGNALLING
AMPAC STROBES
ASL-86 Strobe
• Red or Amber Lens
• High intensity output
• ABS / Polycarbonate / Acrylic construction
•
Combined Red & Amber surface mount unit available
Voltage
24 VDC
Current140mA
10 Watts
Rating
Size inc base
100Dia x 88H mm
Flash rate
75 per minute
Operating temperature
-20°C to + 60°C
IP65
IP rating
Weight – strobe
182 grams
719 grams
Weight – combined unit
ASL-86 Strobe (Red)
ASL-86 Strobe (Amber)
ASL-86 Strobe (Red & Amber) Combined Unit
AUS / PAGE 91
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
208-0007
208-0008
208-0011
EXIT
AUDIO VISUAL SIGNALLING
AMPAC STROBES (Conventional)
Sonos Low Current Visual Warning Device
The SONOS Low Current Visual Warning strobes are general purpose LED
strobes for fire, security and industrial applications. The strobes come with
the flexibility of individual Red, Amber and Clear strobes or combined
Red/Amber strobe units complete with either a flush or surface mounting
plate. The strobes utilises a full faced, translucent case which provides a
much larger lens area and a greater spread of light. The strobes are suitable
for use with AMPAC’s EV3000 system (both single and combined) and
AMPAC’s fire panels (Single only). Simple ‘twist and click’ insertion avoids
wiring and connection problems.
• Low current consumption
• Simple ‘twist and click’ insertion
• Red, Amber and Clear options
• Quick connect/disconnect
•
IP65 weather proof options (deep base units) for indoor
and outdoor use
Operating voltage
17 – 60 VDC
5mA
Current drain
Operating Temperature
-25°C to +70°C
IP Rating Shallow
IP21
IP Rating Deep
IP65
Colour Base
White
Red, Amber, Clear
Colour Lens
ApprovalsC-tick
Sonos Low Current Visual Warning Device (Red)
Sonos Low Current Visual Warning Device (Amber)
Sonos Low Current Visual Warning Device (Clear)
Sonos Low Current Visual Warning Device (Deep Base Only)
208-0060
208-0061
208-0062
208-0064
Combined Strobe for EV3000 (Flush Mount)
Combined Strobe for EV3000 IP65 (Flush Mount)
Combined Strobe for EV3000 (Surface Mount)
208-0063
208-0065
208-0066
Combined Strobe for EV3000
Due to its low current draw the Sonos strokes can be connected in larger
volumes onto the EV3000 visual output circuits.
AUS / PAGE 92
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
AUDIO VISUAL SIGNALLING
AMPAC STROBES (Conventional)
Strobe Sign Plate
Mounts directly behind the Single Red Sonos Strobe. Used outside the
main building entrance which leads fire fighters to the fire indicator panel
location. Outdoor strobes should always use the deep base.
Fixing
Material
Size
Directly behind the Sonos Model Strobe / Beacons
Painted metal 1mm
120mm W X 160mm H
Strobe Sign Plate
AUS / PAGE 93
CONTACT AMPAC
HOME
CONTENTS
SEARCH
207-0042
ZOOM
PRINT
EXIT
AUDIO VISUAL SIGNALLING
AMPAC BELLS
Fire Alarm Bell 150mm
•Motorised mechanism
•Low current consumption
•Red finish with FIRE lettering
•Suitable for indoor use
•Back box available – 206-0006
Voltage
Operating current
Size (without back box)
Sound Level
Operating temperature
Weight
24 VDC
25mA
150Dia x 56D mm
92 dB @ 3m
-10°C to +55°C (no icing)
764 grams
Bell 150mm
206-0012
Fire Alarm Bell 200mm
• Red finish with FIRE lettering
• Solenoid actuating mechanism
•Suitable for indoor use
•Back box available – 206-0006
Voltage
19-27 VDC
Operating current
100mA
Size (without back box)
200Dia x 70D mm
85 dB @ 3m
Sound Level
-20°C to +70°C (no icing)
Operating temperature
Weight1.25kg
Bell 200mm 24Vdc
206-0001
Bell Back Box
• Allows surface mounting of bell
•Screw thread conduit entry and protection for wiring terminals
• Red finish
• Weather seal
Material
Aluminium cast
FinishRed
Depth
40 mm
Weight
270 grams
Bell Back Box for 206-0012 and 206-0001
AUS / PAGE 94
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
206-0006
EXIT
AUDIO VISUAL SIGNALLING
AMPAC KEY HOLDERS
Key Holder – D2
•Provides a visible place to locate a key used for emergency access
•Red finish
•Instructions on glass
•Break glass operation similar to a manual call point
•Suitable for indoor use
AUS / PAGE 95
CONTACT AMPAC
HOME
CONTENTS
Size
100Dia x 32D mm
FinishRed
130 grams
Weight
Key Holder – D2
Spare Glass – D2
SEARCH
215-0003
215-0004
ZOOM
PRINT
EXIT
AUDIO VISUAL SIGNALLING
AMPAC REMOTE INDICATORS
Fire Alarm Remote Indicator – Round
•Detector activation indicator
• 5mm Red LED
• Compact size
• Modern styling
• For conventional or analogue detectors
• Choice of legend
AUS / PAGE 96
CONTACT AMPAC
HOME
Voltage
Current at 24v
Size
Weight
24 VDC
1.5mA
74Dia x 16H mm
26 grams
Remote Indicator – Blank
Remote Indicator – Fire Alarm in Concealed Space
Remote Indicator – Fire Alarm in Roof Space
Remote Indicator – Fire Alarm in Room
Remote Indicator – Fire Alarm in Duct
Remote Indicator – Fire Alarm in Cupboard
Remote Indicator – Fire Alarm Under Floor
Remote Indicator – Fire Alarm in Return Air
Remote Indicator – Fire Alarm in Exhaust Duct
Remote Indicator – Fire Alarm in Supply Air Duct
Remote Indicator – Fire Alarm in Ceiling
Remote Indicator – Fire Alarm Above
Remote Indicator – Fire Alarm
Remote Indicator – Detector Activated
CONTENTS
SEARCH
ZOOM
PRINT
209-0001
209-0004
209-0005
209-0006
209-0007
209-0008
209-0009
209-0010
209-0011
209-0012
209-0013
209-0014
209-0020
209-0023
EXIT
AUDIO VISUAL SIGNALLING
AMPAC REMOTE INDICATORS
Indicator / Buzzer & Indicator / Buzzer with Mute
•Alarm activation indicator and buzzer
•10mm red flashing LED
•Buzzer (with mute facility)
•Modern styling
Indicator / Buzzer
Voltage
24 VDC
Current at 24v
27mA
LED flash rate
45 per minute
Buzzer
3.8kHz @ 114dBA
Size
70H x 110W x 10D mm
Weight64g
Indicator / Buzzer with Mute
Voltage
24 VDC
Current at 24v
43mA
45 per minute
LED flash rate
Buzzer
3.8kHz @ 114dBA
Size
70H x 110W x 10D mm
Weight89g
Flashing Indicator / Buzzer
Flashing Indicator / Buzzer with Mute Switch
AUS / PAGE 97
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
209-0017
209-0016
EXIT
AUDIO VISUAL SIGNALLING
KLAXON SONOS SOUNDER BEACON
Sonos Sounder Beacon
A general purpose electronic sounder beacon for fire, security and
industrial applications. Deep base units have weatherproof protection to
IP65 and can be used in all locations both indoors and outdoors. A full
faced, translucent sounder case rather than a separate add-on beacon
gives a much larger lens area and a greater spread of light.
•
•
•
•
•
•
Simple `First Fix` installation – TimeSaver base
Quick connect/disconnect
Tone and volume can be preset or adjusted off-base
Weatherproof to IP65 (deep base units)
Low current LED beacon
Sounder and beacon can be controlled separately
Audibility at 1m (tone dependent)
Up to 106dB (A)
Tones32
17-60V DC
Voltage
Current
4-45mA (sounder)
5mA (beacon)
IP Rating
IP65 (deep base)
-25°C to +70°C
Operating temperature
215 grams (shallow base)
Weight
250 grams (deep base)
Red Lens Sonos LED Beacon, shallow base
Deep Base (IP65)
Other Colour Combinations Available on Request.
Approvals: EN54-3/LPCB
AUS / PAGE 98
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
205-0105
208-0067
AUDIO VISUAL SIGNALLING
ELECTRONIC SOUNDERS
Vector Sounder
•
AS1670.4 – signal only
•
Externally powered - low current consumption
•
Volume control adjustment
•
Built-in synchronising circuitry with sounders on the same circuit
•
Can be installed as a sounder base for Apollo detectors or a surface
mount sounder when used in conjunction with the optional lid
•
Low profile
•
Available as standard with an XP95 universal base fitted (complete with
opto - interface board) so the sounder can be controlled via the remote
LED output of the XP95 detector
Approvals: AS1670.4
Operating voltage
8 to 35 VDC
15mA @ 24VDC
Supply current Evac
Supply current Alert
8 mA @ 24VDC
Signal output
AS1670.4 – signal only
Max. Output level
91 dBA @ 1 metre with detector
Evac
93 dBA @ 1 metre with lid
-30dBA
Volume control
IP rating
IP42
Temperature range
-20 to + 70°C
ConstructionABS
Dimension (mm)
106Ø x 35h (Sounder & lid only)
Vector Sounder
Vector Sounder Lid
205-0077
205-0017
Vantage Sounder
•
Selectable signals to AS1670.4
•
High output level – up to 100 dB
•
3 selectable output levels
•
Low current consumption for rated output
•
2 or 3 wire configuration
•
Automatic signal changeover facility
•
Excellent lateral sound dispersion
•
Built-in synchronising circuitry
•
Surface mounted
•
Quick-fit deep base option
•
Head to base locking
Voltage
12 to 35 VDC
Low
Med
High
Volume setting
Current (mA @ 27VDC )
7
12
19
Sound Output (dB @ 1m)
85
95
100
SignalsAS1670.4
Size (shallow base)
94 Dia x 85 H mm
93 Dia x 102 H mm
Size (deep base)
Temperature range
-20°C to +70°C
Humidity
0 to 95%
IP Rating (shallow)
IP43
IP Rating (deep)
IP65
Weight
193 grams (deep base +5g)
Approvals: AS1670.4
AUS / PAGE 99
CONTACT AMPAC
Vantage Sounder Red with Shallow Base
Vantage Sounder White with Shallow Base
Deep Base Only Red
Deep Base Only White
HOME
CONTENTS
SEARCH
ZOOM
PRINT
205-0062
205-0063
205-0064
205-0065
EXIT
AUDIO VISUAL SIGNALLING
ELECTRONIC SOUNDER/BEACONS
Vantage Combi
•
•
•
•
•
•
•
•
•
•
•
•
Signals to AS1670.4
High brightness LED strobe
High output level – up to 100dB
3-level selectable sound output levels
Low current consumption less than 70mA
2 or 3-wire configuration
Automatic signal changeover facility
ABS plastic – available in red or white
Excellent lateral sound dispersion
Built-in synchronising circuitry
Surface mounted
Quick-fit lockable base (both shallow and deep base)
Voltage
18 to 35 VDC
Low
Med
High
Volume setting
11
18
30
Current (mA @ 27VDC )
Sound Output (dB @ 1m)
85
95
100
SignalAS1670.4
Flash rate
1 per sec
93 Dia x 90 H mm
Size (shallow)
Size (deep)
93 Dia x 107 H m
Temperature range
-20°C to +70°C
Humidity
0 to 95%
IP Rating (shallow)
IP43
221 grams (deep base +5g)
Weight
Approvals: AS1670.4
AUS / PAGE 100
CONTACT AMPAC
Vantage Combi Red with Shallow Base Vantage Combi White with Shallow Base
Deep Base Only Red
Deep Base Only White
HOME
CONTENTS
SEARCH
ZOOM
PRINT
205-0066
205-0067
205-0064
205-0065
EXIT
ANCILLARIES
Ancillaries
Ampac offers a wide range of Intelligent Ancillary devices for use in conjunction with
its range of intelligent and conventional detectors and control panels. A versatile and
functional range offering a huge choice for any application.
• Power Supplies
• Manual Call Points
•Fittings
• Occupant Warning Systems- Amplified Sound Systems
• Electro Magnetic Door Holders
•Document Cabinets
• Test Equipment
•Sealed Rechargeable Lead Acid Batteries
AUS / PAGE 101
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
ANCILLARIES
POWER SUPPLIES
MultiAmp PSU
The MultiAmp PSU is a general purpose regulated power supply unit.
MultiAmp PSU ABS
•Available in 2A and 3A versions
•Fault Relay Output
•Fault indicator and Resettable Buzzer
•Earth monitoring
•Available in ABS (BX1)
•Available in Metal cabinets (BX10) shallow and deep versions
•2.5mm² cable terminals
A set of two 7Ahr batteries may be housed in the BX1 and BX10 standard
cabinet and a set of two 12Ahr batteries in the BX10 deep cabinet.
(Maximum size based on Ampac battery specifications)
The unit incorporates temperature sensing and compensation whereby a
change in ambient temperature adjusts the battery charging voltage.
The power supply will signal a Low Batt fault at 21.3 VDC.
MultiAmp PSU Metal
AUS / PAGE 102
Approvals: Complies with AS4428/AS7240
CONTACT AMPAC
HOME
CONTENTS
Mains Supply
Operating Voltage
Supply Current
Operating Temperature
Relative Humidity
Battery Capacity:
BX1 and BX10
BX10 Deep Cabinet
Maximum Charge Current
Fault Relay
Dimensions:
ABS Cabinet (BX1)
Metal Cabinet (BX10)
Metal Cabinet (BX10 DEEP)
190 – 264 VAC
27.5 VDC ± 0.2 VDC
2A Current limited (2Amp Version)
3A Current limited (3Amp Version)
0°C to +40°C
25% - 75%
2 x 7Ahr 12V Sealed Lead Acid
2 x 12Ahr 12V Sealed Lead Acid
400mA (2A) 600mA (3A)
NO,C,NC
Contact rating: 1A @ 30VDC
300mm (H) x 360mm (W) x 100mm (D)
300mm (H) x 360mm (W) x 100mm (D)
300mm (H) x 360mm (W) x 200mm (D)
MultiAmp PSU 2A AS/EN Version (ABS BX1)
MultiAmp PSU 3A AS/EN Version (ABS BX1)
MultiAmp PSU 2A AS/EN Version (Metal BX10)
MultiAmp PSU 3A AS/EN Version (Metal BX10)
MultiAmp PSU 2A AS/EN Version (Metal BX10 Deep Cabinet)
MultiAmp PSU 3A AS/EN Version (Metal BX10 Deep Cabinet)
BX10 Surround
SEARCH
ZOOM
PRINT
EXIT
4510-2110
4510-2120
4510-2210
4510-2220
4510-2310
4510-2320
ENC3016-A
ANCILLARIES
POWER SUPPLIES
FastSense Power Supply Unit
•2A power supply (incorporating battery charger)
•Status indication – “POWER ON”, “BATTERY HIGH”, “BATTERY LOW”,
“BATTERY FAIL”
•Battery test facility
•Termination for power supply output – Clearly labelled and adequate
amount of room to terminate
•Panel knockouts – top, side and rear of cabinet
•Optional 6A power supply / battery charger may be fitted to the
FastSense PLUS version
Operating voltage
Output voltage
Max output current
Battery capacity:
FastSense 25 & FastSense 100 versions
FastSense PLUS version
Dimensions:
FastSense 25 & FastSense 100 versions
FastSense PLUS version
Material
Finish
240 VAC
27 VDC
2 Amps @ 27.6 VDC
7 Ah
12 Ah
300 H x 350 W x 130 D mm
320 H x 500 W x 160 D mm
1.6 mm Mild steel
Powder coated Oyster Grey
FastSense PSU – FastSense 25 & FastSense 100 versions
FastSense PSU – FastSense PLUS version
AUS / PAGE 103
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
216-0065
216-0066
ANCILLARIES
Manual Call Points – Conventional
Manual Call Point – ACP-04
•
Double terminal, wire protected connectors for independent input and
output connections when looping to other devices
•
Protective film prevents glass from splintering when broken
•
Open or close circuit operation
•
20 mm conduit entries
•
Testing and resetting the unit with key supplied
•
High reliability micro-switch operation
•
Manufactured from high impact plastic and resistant to heat
•
470Ω in-line resistor
Current Rating
Size
Switch Type
Cable termination
In-Line Resistor
Material
Operating Temperature
Humidity
IP rating
Weight
3A @ 12/24 VDC
1.5A @ 48 VDC
H 88 x W 88 mm
D 59 mm – surface mounted
D 27 mm – flush mounted
Single pole micro
6 x 2.5mm2 screw
470Ω (N/O operation only)
High impact ABS
-5°C to +70°C
0 – 95% non-condensing
IP 24D
153 grams
Manual Call Point – ACP-04 Red
Manual Call Point – ACP-04 Yellow
Manual Call Point – ACP-04 White
Manual Call Point – ACP-04 Green
Manual Call Point – ACP-04 Protective Cover
Manual Call Point – ACP-04 Glass
AUS / PAGE 104
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
213-0060
213-0061
213-0062
213-0063
213-0057
213-0058
EXIT
ANCILLARIES
Manual Call Points
Manual Call Point – Conventional FP2
•
•
•
•
•
•
•
Re-setable operation
No broken glass or frangible element to replace
Tested by actual operation
Fluorescent band indicates call point has been operated
Open or closed circuit operation
Surface and Flush mountable
Transparent lift up cover available
Contact rating
Size (surface mount)
Size (flush mount)
Switch type
Material
Operating Temperature
IP rating
Weight
5A @ 30 VDC
10A @ 250 VAC
87H x 87 W x 54 D mm
87H x 87 W x 16 D mm
Single pole
High impact ABS
-10°C to +70°C
IP44
200 grams
FP2 Red
FP2 White
FP2 Protective Cover
213-0021
213-0022
213-0023
Manual Call Point – Conventional Weatherproof
• Suitable for outdoor use
• Hermetically sealed switches
• Back box supplied
Contact rating
Size
Switch type
Material
Temperature range
IP rating
Weight
5A @ 24 VDC
110H x 110W x 65Dmm
Single Pole
High Impact ABS
-10°C to +70°C
IP67
200 g
Manual Call Point – Conventional Weatherproof
AUS / PAGE 105
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
213-0045
EXIT
ANCILLARIES
Manual Call Points
XP95 Manual Call Point
The XP95 Manual Call Point is compliant with EN54-11. The address of each
call point is set at the commissioning stage by means of a seven segment
DIL switch. The device features plug and play terminal connections and a
resettable element.
•
•
•
•
•
Plug-and-play terminal connectors for fast wiring
Allows wiring continuity testing before fitting
Isolated version available
Reports an alarm in under 0.2 seconds
Resettable element
Voltage
Quiescent current
Alarm current
Address method
Size (surface mount)
Operating temperature
Relative humidity
IP rating
Weight
17-28 VDC
100μA at 24VDC
4mA
7 segment DIL switch
93H x 89W x 59.5D mm
-20°C to +60°C (no icing)
0-95% (non condensing)
IP45
190 grams
XP95 Manual Call Point (Surface)
XP95 Manual Call Point with Isolator (Surface)
XP95 Manual Call Point Protective Cover
Approvals: AS1670.1 and EN54-11
213-0050
213-0051
213-0064
Intelligent Waterproof Manual Call Point
The Intelligent Waterproof Manual Call Point has been designed for use
outdoors and in places where moisture can occur.
•
•
•
•
Plug and play terminal connections for fast wiring
Allow wiring continuity testing before fitting
Isolated version available
Resettable element
Approvals: AS1670.1 and EN54-11
Voltage
Quiescent current
Alarm current
Address method
Size (surface mount)
Operating temperature
Relative humidity
IP rating
Weight
17-28 VDC
230μA
2mA
7 segment DIL switch
87H x 87W x 54D mm
-20°C to +70°C (no icing)
0-95% (non condensing)
IP67
400 grams
Intelligent Waterproof Manual Call Point
Intelligent Waterproof Manual Call Point with Isolator
AUS / PAGE 106
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
213-0066
213-0067
EXIT
ANCILLARIES
Manual Call Points
XP95 Intrinsically Safe Manual Call Point
The XP95 IS Manual Call Point is based on the standard weatherproof model. It
features an ‘interrupt’ facility to provide fast response to an alarm.
• Reports an alarm in under 0.2 seconds
• Waterproof
• IP67
Approvals: AS1670.1 and EN54-11
Voltage
Quiescent current
Alarm current
Address method
Size
Operating temperature
Humidity
IP rating
Weight
Classification
14 to 22 VDC
230uA
2mA
7 segment DIL switch
124H x 124W x 60D mm
-20°C to +60°C (no icing)
0 to 95%
IP67
400 grams
E Ex ia IIc T5
XP95 Intrinsically Safe Manual Call Point
AUS / PAGE 107
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
55100-940
EXIT
ANCILLARIES
Fittings
Wall Boxes
•
Used for flush mounting devices such as manual call points
and sounders
• Suitable for MCP models ACP-01 & FP2
• Suitable for ‘Vara’ sounder
Size
Metal
Plastic
Weight
Metal
Plastic
72H x 72W x 47D mm
72H x 72W x 35D mm
153 grams
47 grams
Wall Box Metal
Wall Box Plastic
AUS / PAGE 108
CONTACT AMPAC
HOME
CONTENTS
SEARCH
268-0002
268-0009
ZOOM
PRINT
EXIT
ANCILLARIES
Occupant Warning Systems
Amplified Sound System – EV20
•Single zone amplified sound system for occupant warning
•Signals to AS1670.4
•Open and short circuit speaker line monitoring and protection
•Manual control / isolation facility
•Volt free Fire Alarm Control Panel input (latching)
•Adjustable volume control
•Automatic changeover between tones
•Fault output
•P.A. microphone input (optional)
•Verbal messaging (optional)
Approvals: AS1670.4
27 VDC
Voltage
41mA
Quiescent current
Max current
650mA
Max output power
20 Watts
Output voltage
100 VAC RMS
SignalsAS1670.4
180L x 82W x 55H mm
Size - main board
Size - controls
90L x 35W x 40H mm
Tone timeout
0, 30, 60, 120, 180, 240
or 300 secs
Weight
690 grams
Amplified Sound System – EV20
Verbal Message
EV20/60/120 Microphone Upgrade Kit
222-0020
222-0026
222-0007
Amplified Sound System – EV40
•Single zone amplified sound system for occupant warning
•Signals to AS1670.4
•Open and short circuit speaker line monitoring and protection
•Manual control / isolation facility
•Volt free Fire Alarm Control Panel input (latching)
•Adjustable volume control
•Automatic changeover between tones
•Fault output
•P.A. microphone input (optional)
•Verbal messaging (optional)
Approvals: AS1670.4
27 VDC
Voltage
Quiescent current
140mA
2.8A
Max current
Max output power
40 Watts
100 VAC RMS
Output voltage
SignalsAS1670.4
Size - main board
170L x 90W x 60H mm
90L x 35W x 40H mm
Size - control card
Tone timeout
0, 30, 60, 120, 150, 180, 210,
240, 270, 300, 360, 420, 480
or 540 secs
Weight
900 grams
Amplified Sound System – EV40
Verbal Message
EV40 Microphone Upgrade
AUS / PAGE 109
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
222-0021
222-0013
294-0001
PRINT
EXIT
ANCILLARIES
Occupant Warning Systems
Amplified Sound System – EV60
•Single zone amplified sound system for occupant warning
•Signals to AS1670.4
•Open and short circuit speaker line monitoring and protection
•Manual control / isolation facility
•Volt free Fire Alarm Control Panel input (latching)
•Adjustable volume control
•Automatic changeover between tones
•Fault output
•P.A. microphone input (optional)
•Verbal messaging (optional)
Approvals: AS1670.4
Voltage
27 VDC
140mA
Quiescent current
Max current
3.9A
Max output power
60 Watts
Output voltage
100 VAC RMS
SignalsAS1670.4
180L x 82W x 55H mm
Size - main board
Size - controls
90L x 35W x 40H mm
Tone timeout
0, 30, 60, 120, 180, 240 or
300 secs
Weight
2.75 kg
Amplified Sound System – EV60
Verbal Message
EV20/60/120 Microphone Upgrade Kit
222-0022
222-0013
222-0007
Amplified Sound System – EV120
•Single zone amplified sound system for occupant warning
•Signals to AS1670.4
•Open and short circuit speaker line monitoring and protection
•Manual control / isolation facility
•Volt free Fire Alarm Control Panel input (latching)
•Adjustable volume control
•Automatic changeover between tones
•Fault output
•P.A. microphone input (optional)
•Verbal messaging (optional)
Approvals: AS1670.4
AUS / PAGE 110
CONTACT AMPAC
Voltage
27 VDC
Quiescent current
260mA
8A
Max current
Max output power
120 Watts
100 VAC RMS
Output voltage
SignalsAS1670.4
Size - main board
170L x 210W x 85H mm
90L x 35W x 40H mm
Size - controls
Tone timeout
0, 30, 60, 120, 180, 240 or
300 secs
Weight
3.7 kg
Amplified Sound System – EV120
Verbal Message
EV20/60/120 Microphone Upgrade Kit
HOME
CONTENTS
SEARCH
ZOOM
PRINT
222-0023
222-0013
222-0007
EXIT
ANCILLARIES
Electro-Magnetic Door Holders
ADH-01 – Electro-Magnetic Door Holder
•
•
•
•
•
•
Available in 24VDC with 50kg/50N holding force
Release switch on housing
Designed for surface mounted
Adjustable door mounted keeper plate
Separate screw terminals to maintain monitoring integrity
Rear and side cable access
Operating Voltage
15 to 29 VDC
55mA @ 24 VDC
Operating Current
50kg
Holding Force
Housing
White High Temperature ABS
Operating Temperature
-10° to +55° C
Dimension (mm)
100h x 100w x 50d
IP 51
IP rating
Weight
750 g
ApprovalC-Tick
ADH-01 – Electro-Magnetic Door Holder, 50kg/50N holding force
212-0012
H1330 – Magnet
•
•
•
•
50kg/50N holding force
Retains fire doors in the open position
In built residual magnetism release pin
Fail safe operation
Voltage
Quiescent current
Size exc anvil
Weight inc anvil
24 VDC
60mA at 24 VDC
65H x 65W x 35D mm
420 grams
H1330 – Magnet, 50kg/50N holding force
AUS / PAGE 111
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
212-0002
EXIT
ANCILLARIES
Electro-Magnetic Door Holders
H1360 – Surface Mount
•Retains fire doors in the open position
•Cover in black ABS
•Container in white aluminium
•In built residual magnetism release pin
•In built manual release switch
•Fail safe operation
Voltage
Quiescent current
Size exc anvil
Weight inc anvil
24 VDC
100mA at 24 VDC
95H x 95W x 40D mm
700 grams
H1360 – Surface Mount, 50kg/50N holding force
H1360 – Surface Mount, 100kg/100N holding force
212-0003
212-0004
H1368 – Flush Mount
• 50kg/50N holding force
•Retains fire doors in the open position
•Flush Mount
•Cover in aluminium
•Housing in galvanised steel
•In built residual magnetism release pin
•Fail safe operation
Voltage
Quiescent current
Size exc anvil
Weight inc anvil
24 VDC
100mA at 24 VDC
120H x 76W x 41D mm
650 grams
H1368 – Flush Mount, 50kg/50N holding force
212-0006
H1369 – Floor Mount
• 50kg/50N holding force
•Retains fire doors in the open position
•Black steel bracket, die-cast aluminium mounting
•In built residual magnetism release pin
•In built manual release switch
•Fail safe operation
AUS / PAGE 112
CONTACT AMPAC
HOME
Voltage
Quiescent current
Size exc anvil
Weight inc anvil
24 VDC
60mA at 24 VDC
100H x 110W x 80D mm
946 grams
H1369 – Floor Mount, 50kg/50N holding force
CONTENTS
SEARCH
ZOOM
PRINT
212-0001
EXIT
ANCILLARIES
Electro-Magnetic Door Holders
H1370 – Floor or Wall Mount
• 50kg/50N holding force
•Retains fire doors in the open position
•Black steel bracket, aluminium support
•In built residual magnetism release pin
•In built manual release switch
•Fail safe operation
Voltage
Quiescent current
Size exc anvil Base
Arm 1370/15
Arm 1370/30
Weight inc anvil
24 VDC
60mA at 24 VDC
125H x 125W x 15D mm
40Dia x 150H mm
40Dia x 300H mm
1.277 kg
H1370/15 – Floor or Wall Mount – 150mm arm
H1370/30 – Floor or Wall Mount – 300mm arm
212-0007
212-0008
H1351 – Anvil
•Retains fire doors in the open position
•Cushioned magnetic support for 50kg electromagnets
•Swivel adjustment
65H x 64W x 48D mm
18 grams
Size
Weight
H1351 – Anvil
212-0009
Remote Door Release
•Remotely releases fire doors held open by electro magnetic door
holder
Size
Weight
70H x 110W x 10D mm
68 grams
Remote Door Release
AUS / PAGE 113
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
268-0003
PRINT
EXIT
ANCILLARIES
Electro-Magnetic Door Holders
MultiAmp-DH
The MultiAmp-DH 250mA Door Holder Supply (DHS) provides up to
250mA of current at 24 VDC to operate door holders. The unit can operate
as an “Automatic Door Release System” (ADRS) or respond to a secondary
control.
When configured as an ADRS, conventional detectors are installed and
connected directly to the DHS. The detection circuit is monitored for
alarm, open, or short circuit conditions. The presence of any one of these
conditions will deactivate supply to the door holders and cause doors to
be released.
Alternatively doors may be released by a switched VDC input to the DHS,
derived normally from a Fire Alarm Control Panel (FACP) or security system.
The switched VDC input must be between 8 to 30VDC to release the
doors.
•Mains powered 240vAC supply
•On board conventional detection zone
•Switches off DH power in alarm condition or atlernatively remote
switched input can trigger the door to release
Mechanical
High Impact ABS
Material
FinishWhite
Dimension (mm)
91H X 149W x 40D (Recessed)
91H X 149W x 53D (Surface)
Weight
400g packed
Power Supply
Mains Supply Voltage
Door Holder Output Voltage
Operating Temperature
Relative Humidity
230 VAC +/- 10% @ 47-63Hz
24 VDC @ 250mA
-5° to +45° C
25% to 95%
Zone Detection Circuit
No of Zones
Zone Monitoring
Zone Current Load
EOL Value
No of detectors/circuit
1 (one), 2-wire system
Open and short-circuit
4.8mA max
3k3 ohm
40 (Max)
Input
Switched VDC Input
Inactive state: 0 to 2 VDC
Active state: 8 to 30 VDC
MultiAmp-DH Flush Mount
MultiAmp-DH Surface Mount
AUS / PAGE 114
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
4510-1100
4510-1101
PRINT
EXIT
ANCILLARIES
DOCUMENT CABINETS
Document Cabinets
AMPAC offers ABS and metal document cabinets designed to complement
the range of AMPAC’s fire control panels. The cabinets can hold in excess of
100 A4 sheets of fire and security information relevant to the premises.
The cabinets are fitted with a lockable front door for security and comes
complete with an internal key holder bracket to allow easy storage of
security keys. Whilst the ABS cabinet is available only in cool grey, there
is a choice of Oyster Grey or Arch White with the metal cabinet option.
• Metal and ABS versions available
• Metal version available in Oyster Grey or Arch White
•Provides the facility to hold documents i.e. Operation and Maintenance
Manuals
• Lockable front door
• Internal key holder bracket
• Designed to complement the AMPAC range of enclosures
AUS / PAGE 115
CONTACT AMPAC
HOME
CONTENTS
Colour
Dimensions
IP Rating
Weight
Key Type
ABS – Cool Grey
Metal – Oyster Grey
Metal – Arch White
ABS – 300H x 360W x 100Dmm
Metal – 295H x 356W x 92Dmm
IP30
ABS – 1kg
Metal – 3kg
003 Key
Document Cabinet ABS – Cool Grey
Document Cabinet Metal – Oyster Grey
Document Cabinet Metal – Arch White
SEARCH
ZOOM
PRINT
4210-0010
4210-0020
4210-0021
EXIT
ANCILLARIES
TEST EQUIPMENT
Test Equipment
•Access poles are used with interchangeable heads that fit onto the end
of the pole
•The equipment is suitable for use on a wide range of detectors
•Poles are telescopic, nonconductive, toughened fibreglass
•Light weight and simple to use
Telescopic Pole 204-0001
Aerosol Smoke Dispenser 204-0004
AUS / PAGE 116
CO Test Can 204-0020
250ml Smoke Can 204-0014
150ml Smoke Can 204-0015
CONTACT AMPAC
Telescopic pole – 6 metre
Extension pole – 1.3 metre
Universal detector removal tool
Aerosol Smoke Dispenser
Heat detector tester – cordless (head only)
Smoke detector test set – 8.2 metre
Smoke detector test set – 6.7 metre
Smoke & cordless heat test set – 4.5 metre
250ml can of smoke (test set use only)
150ml can of smoke (hand held)
Can of smoke for CO detectors (test set use only)
Battery Baton for Cordless Tester
Cordless Heat Detector 204-0017
HOME
CONTENTS
Head Removal Tool
SEARCH
ZOOM
204-0001
204-0002
204-0003
204-0004
204-0017
204-0009
204-0010
204-0018
204-0014
204-0015
204-0020
204-0021
Smoke & Cordless Heat Test Set
PRINT
EXIT
ANCILLARIES
TEST EQUIPMENT
XP95 Test Set (Loop Manager Apollo)
The XP95 Test Set is a self-contained, portable test unit capable of
providing a number of useful functions in relation to individual detectors,
ancillary devices or complete circuits of analogue addressable devices in
the Apollo intelligent ranges. The main function of the test set is to help
the engineer guarantee correct loop configuration before an active control
panel is installed.
Apollo XP95 Test Set
Ampac XP95 Test Set
55000-870EUR
204-0016
•User friendly LCD information display
•Speedy commissioning
•Option for hard copy of results
•No unnecessary site visits
•Significant cost reductions
Discovery Programmer
The Discovery Programmer is a portable test and configuration tool for
Discovery smoke and heat detectors.
Discovery Programmer
53832-030
•Look up the date of manufacture
•Check the drift compensation value
•Display and change the operating mode
•Select/de-select LED flash mode
•Tests detectors
•Reads approval codes
AUS / PAGE 117
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
ANCILLARIES
TEST EQUIPMENT
Flame Sensor Test Unit and Case
The Flame Sensor Test Kit is a tool which is designed to test flame
detectors without the need of real flames.
Flame Sensor Test Unit and Case
29600-226
•Mimics the characteristics of real flames
AUS / PAGE 118
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
ANCILLARIES
Sealed Rechargeable Lead-Acid Batteries
Sealed Rechargeable Lead-Acid Batteries
Ampac sells a comprehensive battery range for all applications requiring a
reliable rechargeable power source. The wide range of sizes coupled with
good cycling ability make them perfect for critical systems such as fire
alarm and emergency warning systems. Designed using VRLA technology,
negating the need to add water, these batteries can be applied in many
critical systems requiring reliable reserve power. Available as 12V or for
very large systems 2 volt cells (x12).
Consideration should be given to the battery space available. If in doubt,
consult your local customer service office.
•VRLA technology (Valve Regulated Lead-Acid)
•No topping up
•Wide capacity range
•Can be operated in any position without leakage
•Long operating life
•Many capacities available
•2 volt cells – very large systems
AUS / PAGE 119
CONTACT AMPAC
HOME
CONTENTS
Voltage (nominal)
12 VDC
CapacityVarious
-15°C to +50°C (no icing)
Operating temperature – charging
– discharging
-20°C to +60°C (no icing)
Life expectancy – standby use
3 to 5 years
Terminal
Quick disconnect or receptacle M5
12 VOLT 1.2 AH SLA 50BP1.212
12 VOLT 3.0 AH 5LA 50BP312
12 VOLT 7AH SLA 50BP712
12 VOLT 12 AH SLA 50BP1212
12 VOLT 17AH SLA 50BP1712
12 VOLT 26AH SLA 50BP2612
12 VOLT 40AH SLA 50BP4012
12 VOLT 65AH 50BP6512
210-0008
210-0006
210-0016
210-0010
210-0003
210-0012
210-0013
210-0015
12 VOLT 90AH SLA 50BP9012
BATT 12 VOLT 100AH E12V100
12VOLT 120AH 50BP12012
210-0002
210-0009
210-0022
Extra large 12 Volt (consideration of battery cabinet space required)
12V 160AH 50BP16012
12 VOLT 230AH SLA 50BP23012
210-0017
210-0011
Extra large 12 Volt (consideration of battery cabinet space required)
2 Volt Cells (12 x Cells are required)
210-0018 2VOLT 250AH UPZ 2-250
210-0019 2VOLT 300AH UXL-330-2
210-0020 2VOLT 550AH UXL-550-2
210-0018
210-0019
210-0020
SEARCH
ZOOM
PRINT
EXIT
CONTACT Australia Customer Service Offices
NEW SOUTH WALES &
AUSTRALIAN CAPITAL TERRITORY
Unit B 28-32 Egerton Street
Silverwater
New South Wales 2128
WESTERN AUSTRALIA
7 Ledgar Road
Balcatta
Western Australia 6021
Telephone: +618 9201 6110
Fax: +618 9201 6111
Email: [email protected]
Mobile: 0421 129 163
Contact:
Lester Gaskin
Paul Beer
Contact:
David Lehn
Wes McMillan
Mason Truong
VICTORIA & TASMANIA
422 Johnston Street
Abbotsford
Victoria 3067
QUEENSLAND
1/53 Parramatta Road,
Underwood,
Queensland 4119
Telephone: +613 8459 3300
Fax: +613 9416 4227
Email: [email protected]
Mobile: 0417 331 473
Telephone: +617 3462 5700
Fax: +617 3208 9355
Email: [email protected]
Mobile: 0409 630 633
Contact:
Tom Stroumos
Nick Vangeli
Ian Siemonek
Contact:
Michael Schuster
Sam Adams
CONTACT AMPAC
Telephone: +618 8246 3800
Fax: +618 8340 4218
Email: [email protected]
Mobile: 0400 835 969
Telephone: +612 8866 6200
Fax: +612 9648 4932
Email: [email protected]
Mobile: 0417 986 847
Contact:
Joe Fusari
David Thomas
Lukasz Swietojanski
AUS / PAGE 120
SOUTH AUSTRALIA
63 Grange Road
Welland
South Australia 5032
HOME
CONTENTS
NORTHERN TERRITORY
2/10 Cato St, Winnellie
Northern Territory, 0820
SEARCH
Telephone: +618 8911 1260
Fax: +618 8911 1261
Email: [email protected]
Mobile: 0451 632 965
Contact:
Matt Cavenagh
ZOOM
PRINT
EXIT
CONTACT
Head Office & Administration
HEAD OFFICE & ADMINISTRATION
Ampac Technologies Pty Ltd
7 Ledgar Road
Balcatta
Western Australia 6021
Telephone:
+618 9201 6100
Fax:
+618 9201 6101
Email:
[email protected]
Web:
www.ampac.net
CLICK HERE TO VIEW CUSTOMER SERVICE OFFICES
As part of Ampac’s commitment to continuous improvement, specifications
may change without notice.
Version AUS/15-05-2012
Planned, written, designed and produced by Right Angle • www.rightangle.co.uk
AUS / PAGE 121
CONTACT AMPAC
HOME
CONTENTS
SEARCH
ZOOM
PRINT
EXIT
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement