262874-BTG-C-1208 TECHNICAL GUIDE DESCRIPTION HIGH EFFICIENCY SINGLE PACKAGE HEAT PUMPS BA-06, -07, -08, -10 and -12 6-1/2, 7-1/2, 8-1/2, 10, and 12-1/2 NOMINAL TONS 9.3-10.7 EER Unitary Products BA units are convertible single packages with a common footprint cabinet and common roof curb for all 6-1/2 through 12-1/2 ton models. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All BA heat pump units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage sizes. Tested in Accordance With: ISO 9001 Certified Quality Management System FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 262874-BTG-C-1208 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Tbl. # FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 14 HEATING APPLICATION DATA 12-1/2 TON UNIT . . 20 15 ELECTRICAL DATA BA-06 (6-1/2 TON) HP W/O PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 21 16 ELECTRICAL DATA BA-06 (6-1/2 TON) HP WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 21 17 ELECTRICAL DATA BA-07 (7-1/2 TON) HP W/O PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 22 18 ELECTRICAL DATA BA-07 (7-1/2 TON) HP WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 22 19 ELECTRICAL DATA BA-08 (8-1/2 TON) HP W/O PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 23 20 ELECTRICAL DATA BA-08 (8-1/2 TON) HP WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 23 21 ELECTRICAL DATA BA-10 (10 TON) HP W/O POWERED CONVENIENCE OUTLET . . . . . . . . . . . 24 22 ELECTRICAL DATA BA-10 (10 TON) HP WITH POWERED CONVENIENCE OUTLET . . . . . . . . . . . 24 23 ELECTRICAL DATA BA-12 (12-1/2 TON) HP W/O POWERED CONVENIENCE OUTLET . . . . . . . . . . . 25 24 ELECTRICAL DATA BA-12 (12-1/2 TON) HP WITH POWERED CONVENIENCE OUTLET . . . . . . . . . . . 25 25 ELECTRIC HEAT MULTIPLIERS . . . . . . . . . . . . . . . 25 26 6-1/2 TON SIDE SHOT BLOWER PERFORMANCE . 26 27 7-1/2 TON SIDE SHOT BLOWER PERFORMANCE . 27 28 8-1/2 TON SIDE SHOT BLOWER PERFORMANCE . 28 29 10 TON SIDE SHOT BLOWER PERFORMANCE . . . 29 30 12-1/2 TON SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 31 6-1/2 TON DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 32 7-1/2 TON DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 33 8-1/2 TON DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 34 10 TON DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 35 12-1/2 TON DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 36 ADDITIONAL STATIC RESISTANCE 50-3/4" CABINET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 37 ADDITIONAL STATIC RESISTANCE 42" CABINET . 36 38 ELECTRIC HEAT MINIMUM SUPPLY AIR . . . . . . . . 37 39 INDOOR BLOWER SPECIFICATIONS . . . . . . . . . . . 37 40 POWER EXHAUST SPECIFICATIONS . . . . . . . . . . . 37 41 4 POINT LOAD WEIGHT . . . . . . . . . . . . . . . . . . . . . . 38 42 6 POINT LOAD WEIGHT . . . . . . . . . . . . . . . . . . . . . . 39 43 UNIT WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 44 UNIT HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 45 UNIT CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . 39 46 ECONOMIZER USAGE . . . . . . . . . . . . . . . . . . . . . . . 40 FACTORY INSTALLED OPTIONS . . . . . . . . . . . . . . 5 FIELD INSTALLED ACCESSORIES . . . . . . . . . . . . 6 NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . 9 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 48 LIST OF FIGURES Fig. # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Pg.# BA COMPONENT LOCATION . . . . . . . . . . . . . . . . . . . 3 UNIT 4 POINT LOAD . . . . . . . . . . . . . . . . . . . . . . . . . 38 UNIT CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . 38 UNIT 6 POINT LOAD . . . . . . . . . . . . . . . . . . . . . . . . . 38 UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DOWNFLOW ECONOMIZER HOOD DETAIL . . . . . . 40 FACTORY INSTALLED DOWNFLOW ECONOMIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . 41 FIELD INSTALLED HORIZONTAL ECONOMIZER W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . 42 SLAB ECONOMIZER DOWNFLOW W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 SLAB ECONOMIZER END RETURN W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 ROOF CURB DIMENSIONS . . . . . . . . . . . . . . . . . . . . 43 TRANSITION ROOF CURBS . . . . . . . . . . . . . . . . . . . 44 BOTTOM DUCT OPENINGS (FROM ABOVE) . . . . . 44 REAR DUCT DIMENSIONS . . . . . . . . . . . . . . . . . . . . 45 TYPICAL 6-1/2 TON HEAT PUMP WITH OR WITHOUT ELECTRIC HEAT WIRING DIAGRAM . . . . . . . . . . . . 46 TYPICAL 7-1/2 - 12-1/2 TON HEAT PUMP WITH OR WITHOUT ELECTRIC HEAT WIRING DIAGRAM. . . . 47 LIST OF TABLES Tbl. # 1 2 3 4 5 6 7 8 9 10 11 12 13 2 Pg.# ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 BA CAPACITY RATINGS . . . . . . . . . . . . . . . . . . . . . . 10 UNIT VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . 10 COOLING CAPACITY 6-1/2 TON UNIT . . . . . . . . . . . 11 COOLING CAPACITY 7-1/2 TON UNIT . . . . . . . . . . . 12 COOLING CAPACITY 8-1/2 TON UNIT . . . . . . . . . . . 13 COOLING CAPACITY 10 TON UNIT . . . . . . . . . . . . . 14 COOLING CAPACITY 12-1/2 TON UNIT . . . . . . . . . . 15 HEATING APPLICATION DATA 6-1/2 TON UNIT . . . 16 HEATING APPLICATION DATA 7-1/2 TON UNIT . . . 17 HEATING APPLICATION DATA 8-1/2 TON UNIT . . . 18 HEATING APPLICATION DATA 10 TON UNIT. . . . . . 19 Pg.# Johnson Controls Unitary Products 262874-BTG-C-1208 SimplicityTM Control board w/screw connectors for T-stat wiring and network connection Terminal block for hi-voltage connection Disconnect location (optional disconnect switch) Filter access (2” throw-away) Filter drier (solid core) Condenser section Second Model Nameplate Inside Control Door Slide-out motor and blower assembly for easy adjustment and service. Dual stage cooling for maximum comfort (7-1/2 12-1/2 Only) Compressor #2 Access (High-Eff Compressor) Base Rails w/ Forklift Slots (3 Sides) & Lifting Holes Belt-drive blower motor Roof curbs in eight- and fourteen-inch heights. Roof curbs for transitioning from footprint to the BA series footprint are also available (field installed accessory) Toolless Door Latch FIGURE 1 - Side entry power and control wiring knockouts Compressor #1 Access (High-Eff Compressor) Slide-out drain pain with steel 3/4” NPT, Female Connection BA COMPONENT LOCATION FEATURES Service windows have been placed in both condenser section walls. Rotation of the cover allows easy access to the condenser coils for cleaning or inspection. • High Efficiency – High efficiency units reach as high as 10.7 EER. • Service Friendly – The BA incorporates a number of enhancements which improve serviceability. The unit control board utilizes flash codes to aid in diagnosis of unit malfunctions. Unique flash codes quickly identify the source of the unit alarm. The motor and blower slide out of the unit as a common assembly. This facilitates greater access to all the indoor airflow components, thus simplifying maintenance and adjustment. All units use the same standard filter size. This standardization removes any confusion on which filter sizes are needed for replacement. Service time is reduced through the use of hinged, toolless panels. Such panels provide access to frequently inspected components and areas, including the control box, compressors, filters, indoor motor & blower, and the heating section. The panels are screwed in place at the factory to prevent access by children or other unauthorized persons. It is recommended that the panels be secured with screws once service is complete. Johnson Controls Unitary Products The non-corrosive drain pan slides out of the unit to permit easy cleaning. The drain pan is accessed by removing the drain pan cover plate on the rear of the unit. Once the plate is removed, the drain pan slides out through the rear of the unit. All BA units have a second model nameplate located inside the control access door. This is to prevent deterioration of the nameplate through weathering. 3 262874-BTG-C-1208 • Environmentally Aware – For improved Indoor Air Quality, foil faced insulation is used exclusively throughout the units. • Convertible Airflow Design – The side duct openings are covered when they leave the factory. If a side supply/return is desired, the installer simply removes the two side duct covers from the outside of the unit and installs them over the down shot openings. No panel cutting is required. Convertible airflow design allows maximum field flexibility and minimum inventory. • • System Protection - Suction line freezestats are supplied on all units to protect against loss of charge and coil frosting when the economizer operates at low outdoor air temperatures while the compressors are running. Every unit has solid-core liquid line filter-driers and high and low-pressure switches. Internal compressor protection is standard on all compressors. Crankcase heaters are standard on reciprocating compressors. Scroll compressors do not require crankcase heaters. Phase Monitors are standard on units with scroll compressors. This accessory monitors the incoming power to the unit and protects the unit from phase loss and reversed phase rotation. Advanced Controls - Simplicity™ control boards have standardized a number of features previously available only as options or by utilizing additional controls. • Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0°F outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. The Simplicity® control board used in this product will effectively operate the cooling system down to 0°F when this product is applied in a comfort cooling application for people. An economizer is typically included in this type of application. When applying this product for process cooling applications (computer rooms, switchgear, etc.), please reference applications bulletin AE-011-07 or call the applications department for Unitary Products @ 1-877UPG-SERV for guidance. Additional accessories may be needed for stable operation at temperatures below 30° F. • 4 Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti-short cycle delay can be temporarily overridden with the push of a button. • Fan Delays - Fan on and fan off delays are fully programmable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heating. • Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats and the temperature limit switch on electric heat units. The unit control board will alarm on compressor lockouts and repeated limit switch trips. • Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three times, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor. • On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. • Reliable – From the beginning – All units undergo computer automated testing before they leave the factory. Units are tested for refrigerant charge and pressure, unit amperage, and 100% functionality. All BA units are painted with a long lasting, powder paint that stands up over the life of the unit. The paint used has been proven by a 1000 hour salt spray test. • Flexible Placement – All models and configurations share the same cabinet/footprint and thus the same roof curb. You have the flexibility to set one curb and choose the correct tonnage size after the internal loads have been determined. To further simplify planning and installation, BA cabinets are designed to fit your roof. With the optional roof curb, the unit ductwork is designed to fit around 24” on-center joists or between 48” on-center joists. The drain pan can be rotated to drain to either the front or the rear of the unit. Additionally, the drain pan can be fitted to drain through the roof curb. As it is sometimes difficult to have a level installation, the drain pan features a generous slope to ensure proper drainage. • Full Perimeter Base Rails – The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails offer forklift access from 3 sides, and rigging holes are available so that an overhead crane can be used to place the units on a roof. Johnson Controls Unitary Products 262874-BTG-C-1208 • Easy Installation – Electric utility knockouts are supplied in the unit underside as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. order a 1RD0411 Barometric Relief for horizontal flow economizers only. • BAS Ready Economizer -(With barometric relief) - The economizer is provided with an actuator that requires a 0-10V DC input from an external source (i.e., field installed building automation system controller). Power exhaust options are available. The economizer is 2% low leakage type with spring return and fully modulating dampers capable of introducing up to 100% outside air. Also include 2” pleated filters. • Slab Economizer for Energy Recovery Ventilators- (With barometric relief and Fresh Air Hood) - The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type, and is shipped installed and wired. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. All units are shipped with 2” throw-away filters installed. • • Wide Range of Indoor Airflows – All indoor fan motors are belt-drive type providing maximum flexibility to handle most airflow requirements. For high static applications, factory installed alternate indoor fan motors are available. With the optional indoor fan motor, all units can supply nominal airflow at up to 1.5” ESP. Warranty - All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry a 5-year warranty. FACTORY INSTALLED OPTIONS UP offers several equipment options factory installed, for the BA line. • Optional Factory Installed Economizers - BA units offer a variety of optional factory installed economizers with low leak dampers. The outdoor air enthalpy sensor enables economizer operation if the outdoor enthalpy is less than the setpoint of the economizer logic module. See Table 46 to determine the correct economizer for your application. • • Downflow Economizer - (With barometric relief) The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type, and is shipped installed and wired. The installer needs only to assemble and mount the outdoor air hood (Provided). The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. Horizontal Economizer - (Without barometric relief) - All features of the downflow economizer exist except you must order the duct mount barometric relief separately. You must order a 1EH0408 if you are installing a power exhaust. You can Johnson Controls Unitary Products • Power Exhaust (Downflow only) - This accessory installs in the unit with a down flow economizer. • Motorized Outdoor Air Damper - The motorized outdoor air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The outdoor air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory. • Alternate Indoor Blower Motor - For applications with high static restrictions, units are offered with optional indoor motors that provide higher static output and/or higher airflow, depending upon the installer’s needs. • Electric Heaters - The electric heaters range from 9kW to 54kW and are available in all the voltage options of the base units. All heaters are dual staged. All heaters are intended for single point power supply. • Disconnect Switch - For heat pumps with electric heat, an HACR breaker sized to the unit is provided. For heat pump only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. 5 262874-BTG-C-1208 • Convenience Outlet - (Non-Powered /Powered) - This option locates a 120V single-phase GFCI outlet with cover, on the corner of the unit housing adjacent to the compressors. The “Non-powered” option requires the installer to provide the 120V single-phase power source and wiring. The “Powered” option is powered by a stepdown transformer in the unit. Factory installed option only. • Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. Available for both the supply and/or return air. Factory installed smoke detectors in the return air, may be subjected to freezing temperatures during "off" times due to out side air infiltration. These smoke detectors have an operational limit of 32 °F to 131°F. Smoke detectors installed in areas that could be out side those limitations will have to be moved to prevent having false alarms. • • • • Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of phase condition. (Standard on units with Scroll Compressors.) Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. Additionally, this kit stops animals and foreign objects from entering the space between the inner condenser coil and the main cabinet. This is not a hail guard kit. Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. Stainless Steel Drain Pan - An optional rust-proof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. • Technicoat Condenser Coils - The condenser coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • Technicoat Evaporator Coil - The evaporator coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • 6 BAS - Building Automation System Controls Simplicity™ INTELLI-Comfort™ Control - The UP Simplicity™ INTELLI-Comfort™ control is factory installed. It includes a supply air sensor, a return air sensor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor, a Return Air Humidity sensor, an Inside IAQ sensor, and an Outside Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort™ using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the on-board connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity™ INTELLI-Comfort™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort. • Simplicity™ INTELLI-Comfort™ with Mod Link Control - The UP Simplicity™ INTELLI-Comfort™ with Mod Link control is factory installed. It includes all the features of the INTELLI-Comfort™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol. • Novar® BAS Control - The Novar® building automation system controller is factory installed. Incudes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. • Johnson Controls BAS Control - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. • CPC BAS Control - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. • Honeywell BAS Control - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch and air proving switch. FIELD INSTALLED ACCESSORIES UP offers several equipment accessories for field installation, for the BA line. • Downflow Economizer - (With barometric relief) - The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers Johnson Controls Unitary Products 262874-BTG-C-1208 close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. • • Horizontal Economizer - (Without barometric relief) All features of the downflow economizer exist except you must order the duct mount barometric relief separately. You must order a 1EH0408 if you are installing a power exhaust. You can order a 1RD0411 Barometric Relief for horizontal flow economizers only. Slab Economizer for Energy Recovery Ventilator(Without barometric relief or Fresh Air Hood) - The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. You can order 1EH0409 Barometric Relief/FA Hood for field installations without an ERV. • Dual Enthalpy Control, Accessory - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. • Barometric Relief Damper - Zero to 100% capacity barometric relief dampers for use with horizontal flow, or field installed slab economizers. • Power Exhaust - This accessory installs in the unit with a down flow economizer. Power exhaust plugs into the connector in the unit bulkhead. You must purchase 1EH0408 barometric relief/power exhaust hood when applying to a horizontal flow application. • Manual Outdoor Air Damper - Like the motorized outdoor air damper, each manual outdoor air damper includes a slide-in damper assembly with an outdoor air hood and filters. Customers have a choice of dampers Johnson Controls Unitary Products with ranges of 0% to 100% or 0% to 35% outdoor air entry. • Motorized Outdoor Air Damper - The motorized outdoor air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The outdoor air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory. • Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. • CO2 Sensor - Senses CO2 levels and automatically overrides the economizer when levels rise above the preset limits. • Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. • Coil Guard - Field installed decorative wire coil guard. • Hail Guard - This kit includes a sloped hood which installs over the outside condenser coil and prevents damage to the coil fins from hail strikes. Field installed accessory only. • Electric Heaters - The electric heaters range from 9 kW to 54kW and are available in all the voltage options of the base units. All heaters are dual staged. Cooling units include an adapter panel for easy installation of the electric heaters. Necessary hardware and connectors are included with the heaters. All heaters are intended for single point power supply. • Metal Frame Filter Kit - Metal frame with polyester filter medium. • Permanent Filters - Permanent filters are available. • Roof Curbs - The roof curbs have insulated decks and are shipped disassembled The roof curbs are available in 8” and 14” heights. For applications with security concerns, burglar bars are available for the duct openings of the roof curbs. • Roof Curb Transition - Single Piece Adapter (10” High) - Roof curbs for transitioning from BCB/DBF units to BA units. Fits 7.5 to 12.5 BCB/DBF roof curbs only. • Burglar Bars - Mount in the supply and return openings to prevent entry into the duct work. • Thermostat - The units are designed to operate with 24volt electronic and electro-mechanical thermostats. All units (with or without an economizer) operate with twostage heat/two-stage cool or two-stage cooling only thermostats, depending upon unit configuration. 7 262874-BTG-C-1208 TABLE 1: ACCESSORIES Part Number 1RC0470 1RC0471 1RC0472 1BD0408 2TP04520925 2TP04521825 2TP04522425 2TP04523625 2TP04525425 2TP04520946 2TP04521846 2TP04522446 2TP04523646 2TP04525446 2TP04520958 2TP04521858 2TP04522458 2TP04523658 2TP04525458 2TP04540925 2TP04541825 2TP04542425 2TP04543625 2TP04540946 2TP04541846 2TP04542446 2TP04543646 2TP04540958 2TP04541858 2TP04542458 2TP04543658 1FA0413 1FA0414 2MD04702724 2MD04703324 2EE04705424 2EE04705524 2EE04705224 2EE04705624 2PE04703225 2PE04703246 2PE04703258 2EC04700924 1EH0407 1RD0411 1EH0408 1EH0409 2AQ04700424 2AQ04700324 2SD04700424 1CG0419 1CG0427 1HG0411 1HG0415 1FL0402 1FL0423 2DF0401 1FF0410 1FF0411 8 Description Weight Roof Curb, 8" Height Roof Curb, 14" Height Roof Curb, Transition (7.5 T through 12.5 T) Burglar Bars, Downflow Electric Heat 9kW 230V Electric Heat 18kW 230V Electric Heat 24kW 230V Electric Heat 36kW 230V Electric Heat 54kW 230V Electric Heat 9kW 460V Electric Heat 18kW 460V Electric Heat 24kW 460V Electric Heat 36kW 460V Electric Heat 54kW 460V Electric Heat 9kW 575V Electric Heat 18kW 575V Electric Heat 24kW 575V Electric Heat 36kW 575V Electric Heat 54kW 575V Electric Heat 9kW 230V, 42" Tall Cabinet Electric Heat 18kW 230V, 42" Tall Cabinet Electric Heat 24kW 230V, 42" Tall Cabinet Electric Heat 36kW 230V, 42" Tall Cabinet Electric Heat 9kW 460V, 42" Tall Cabinet Electric Heat 18kW 460V, 42" Tall Cabinet Electric Heat 24kW 460V, 42" Tall Cabinet Electric Heat 36kW 460V, 42" Tall Cabinet Electric Heat 9kW 575V, 42" Tall Cabinet Electric Heat 18kW 575V, 42" Tall Cabinet Electric Heat 24kW 575V, 42" Tall Cabinet Electric Heat 36kW 575V, 42" Tall Cabinet Manual Outside Air Damper 0-35%, Downflow (Incl. Hood, Damper & Filters, No Barometric Relief) Manual Outside Air Damper 0-100%, Downflow (Incl. Hood, Damper & Filters, No Barometric Relief) Motorized Damper, Downflow (Incl. Hood, Damper & Filter, no Barometric Relief) Motorized Damper, Horizontal (Incl. Hood, Damper & Filter, no Barometric Relief) Economizer, Downflow (Incl. Barometric Relief & All Hoods) 124 lbs. Economizer, Horizontal (Incl. Dampers & Hoods, no Barometric Relief) 97 lbs. Economizer, Slab, Downflow (Incl. Dampers only no Hoods or Barometric Relief) "Downflow Economizer, Slab type for ERV (no Barometric Relief or FA hood)", 42" Tall Cabinet Power Exhaust, Downflow, 230V (For Units with Economizer only) Power Exhaust, Downflow, 460V(For Units with Economizer only) Power Exhaust, Downflow, 580V (For Units with Economizer only) Dual Enthalpy Control (Use with Single Enthalpy Economizer) Hood Kit, Downflow Economizer (Included with all Downflow Economizers) Barometric Relief Kit, Ductmount for Horizontal Application (Incl. Damper & Hood) Barometric Relief Kit, Ductmount for Horizontal Application w/Power Exhaust (Incl. Damper & Hood) 25 lbs. Barometric Relief / Hood Kit, for Field Installed Slab Econ. w/o ERV (Incl. Barometric Relief & FA Hood) CO2 Detector Unit Mount CO2 Detector Space Mount Smoke Detector, Supply or Return (Return Not Available with Horizontal Economizer) Coil Guard (Electric / Electric & HP models) Coil Guard (Electric / Electric & HP Models), 42" Tall Cabinet Hail Guard Kit Hail Guard Kit, 42" Tall Cabinet Permanent Filter (Includes (4) Four Filters) Permanent Filter (Includes (4) Four Filters), 42" Tall Cabinet Dirty Filter Switch Filter Frame Kit, Metal Metal Filter Frame Kit, 42" Tall Cabinet Johnson Controls Unitary Products 262874-BTG-C-1208 NOMENCLATURE 6.5-12.5 Ton Model Number Nomenclature B A -10 C00 A T A AA 3 0 1 2 4 A Product Category Product Style A = Style A B = Style B B = HP, Single Pkg., R-22 Product Identifier Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. A = 9.3-10.6 EER HP SS Drain Pan CPC Controller, DFS, APS Nominal Cooling Capacity Johnson Controller, DFS, APS Honeywell Controller, DFS, APS -06 = 6.5 Ton -07 = 7.5 Ton -08 = 8.5 Ton -10 = 10.0 Ton -12 = 12.5 Ton Novar Controller, DFS, APS Simplicity IntelliComfort Controller Simplicity IntelliComfort Controller w/ModLinc 2" Pleated filters BAS Ready Unit with Economizer Shipping Bag Heat Type and Nominal Heat Capacity Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned C00 = Cooling Only. No heat installed Product Generation Electric Heat Options 3 = Third Generation 4 = Fourth Generation E09 = 9 KW E18 = 18 KW E24 = 24 KW E36 = 36 KW E54 = 54 KW Additional Options Airflow A = Std. Motor B = Std. Motor/Econo./Barometric Relief (Downflow Only) C = Std. Motor/Econo./Power Exhaust (Downflow Only) D = Std. Motor/Motorized Damper (Downflow Only) E = Std. Motor/Horizontal Economizer (No Baro.) F = Std. Motor/Slab Econo./Power Exhaust (Downflow Only) G = Std. Motor/Slab Econo./Barometric Relief (Downflow Only) N = Hi Static P = Hi Static/Econo./Barometric Relief (Downflow Only) Q = Hi Static/Econo./Power Exhaust (Downflow Only) R = Hi Static/Motorized Damper (Downflow Only) S = Hi Static/Horizontal Economizer (No Baro.) T = Hi Static/Slab Econo./Power Exhaust (Downflow Only) U = Hi Static/Slab Econo./Barometric Relief (Downflow only) Voltage T = 208/230-3-60 W = 460-3-60 X = 575-3-60 AA = None AB = Phase Monitor AC = Coil Guard AD = Dirty Filter Switch AE = Phase Monitor & Coil Guard AF = Phase Monitor & Dirty Filter Switch AG = Coil Guard & Dirty Filter Switch AH = Phase Monitor, Coil Guard & Dirty Filter Switch TA = Technicoat Condenser Coil TJ = Technicoat Evaporator Coil TS = Technicoat Evaporator & Condenser Coils ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18. Installation Options A = No Options Installed B = Option 1 C = Option 2 D = Options 1 & 2 E = Option 3 F = Option 4 G = Options 1 & 3 H = Options 1 & 4 J = Options 1, 2 & 3 K = Options 1, 2, & 4 L = Options 1,3 & 4 M = Options 1, 2, 3, & 4 N = Options 2 & 3 P = Options 2 & 4 Q = Options 2, 3, & 4 R = Options 3 & 4 S = Option 5 T = Options 1 & 5 U = Options 1, 3, & 5 V = Options 1, 4, & 5 W = Options 1, 3, 4, & 5 X = Options 3 & 5 Y = Options 4 & 5 Z = Options 3, 4 & 5 Options 1 = Disconnect 2 = Non-Pwr'd Conv. Outlet 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. 5 = Pwr'd Conv. Outlet Johnson Controls Unitary Products 9 262874-BTG-C-1208 TABLE 2: PHYSICAL DATA Model Component -06 -07 -08 -10 -12 Blower, Centrifugal (Dia. X Wd. in.) 15x15 12 x 12 15x15 15 x 15 15 x 15 Motor, Standard (HP) 1-1/2 2 2 2 3 Motor, Optional (HP) 2 3 3 3 5 Rows 3 3 3 4 4 Fins per Inch 15 15 15 15 15 Height (in.) 40 32 40 40 40 Face Area (ft.2 each) 13.2 10.6 13.2 13.2 13.2 Evaporator Blower Evaporator Coil Condenser Fan (2 per Unit) Propeller Dia. (in., each) 24 24 24 24 24 Motor (HP, each) 1/3 1/3 3/4 3/4 3/4 CFM, Nominal (each) 1700 1700 2200 2200 2200 Rows (each) 1 2 2 2 2 Fins per Inch 20 20 20 20 20 Height (in., each) 44 36 44 44 44 Condenser Coil (2 per unit) 2 Face Area (ft. each) 14.5 11.9 14.5 14.5 14.5 System 1 (lb./oz.) 18/0 12/0 13/8 15/4 12/12 System 2 (lb./oz.) N/A 12/0 13/8 15/4 12/12 Quantity 1 2 2 2 2 Type Scroll Recip Recip Recip Scroll Size (Wd. x Ht. x Thickness in.) 25x20x2 25x16x2 25x20x2 25x20x2 25x20x2 Number Per Unit 4 4 4 4 4 Refrigerant Charge Compressors Air Filters TABLE 3: BA CAPACITY RATINGS Size (Tons) Cooling Capacity ARI Ratings* Heating Capacity CFM Sound Rating Nom Elec (dB)† Heat Cap‡ (kW) 2.2 84 9, 18, 24 34 46 2.2 90 9, 18, 24 34 3.2 56 2.2 90 9, 18, 24 34 113 3.2 60 2.2 90 18, 24, 34 54 142 3.1 91 2.1 90 18, 24, 34 54 MBH @ 47° F COP @ 47°F MBH @ 17°F COP @ 17°F MBH EER IPLV -06 (6-1/2) 78 10.2 N/A 2600 69 3.2 43 -07 (7-1/2) 89 10.6 11.08 2635 85 3.2 -08 (8-1/2) 102 10.3 10.3 3400 100 -10 (10) 120 10.3 10.0 3750 -12 (12-1/2) 144 9.3 9.7 4750 * Rated at 95°F ambient 80°F dry bulb and 67°F wet bulb. † Rated in accordance with ARI 270 standard. ‡ See Table 25. TABLE 4: UNIT VOLTAGE LIMITATIONS 10 POWER RATING MIN. MAX. 208/230-3-60 460-3-60 575-3-60 187 252 432 504 540 630 Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 5: COOLING CAPACITY 6-1/2 TON UNIT Air On Evap. Coil CFM 1950 2275 2600 2925 3250 1950 2275 2600 2925 3250 1950 2275 2600 2925 3250 Temperature of Air on Condenser Coil 85°F WB (°F) Tot. Cap.* (MBH) 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 76.1 70.6 66.1 64.6 84.1 78.0 73.1 71.4 92.1 85.4 80.0 78.2 93.7 86.9 81.4 79.6 95.3 88.3 82.8 80.9 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 70.4 63.9 60.9 59.5 77.3 70.1 66.9 65.3 84.1 76.4 72.8 71.2 86.3 78.4 74.7 73.0 88.5 80.3 76.6 74.8 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 64.0 57.0 55.5 54.2 69.3 61.7 60.1 58.7 74.6 66.4 64.7 63.2 76.2 67.8 66.1 64.6 77.9 69.3 67.5 65.9 Tot. Input† (kW) Temperature of Air on Condenser Coil 95°F Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 83 80 77 74 71 6.05 63.7 58.1 52.6 47.0 41.5 5.87 70.6 70.6 70.0 64.4 58.9 53.3 5.68 66.1 66.1 66.1 60.6 55.0 49.4 5.68 64.6 64.6 64.6 59.1 53.5 48.0 6.26 63.0 56.4 49.8 43.3 36.7 6.07 74.2 70.4 66.3 59.8 53.2 46.6 5.87 73.1 73.1 71.7 65.1 58.6 52.0 5.87 71.4 71.4 71.1 64.5 58.0 51.4 6.46 62.2 54.7 47.1 39.5 31.9 6.27 77.8 70.2 62.7 55.1 47.5 39.9 6.07 80.0 80.0 77.3 69.7 62.1 54.5 6.06 78.2 78.2 77.6 70.0 62.4 54.8 6.48 67.6 59.0 50.4 41.7 33.1 6.28 83.1 75.7 67.1 58.4 49.8 41.2 6.08 81.4 81.4 80.0 71.4 62.8 54.1 6.08 79.6 79.6 79.2 70.6 62.0 53.3 6.49 73.1 63.4 53.7 44.0 34.3 6.30 88.3 81.2 71.5 61.8 52.1 42.4 6.09 82.8 82.8 82.8 73.1 63.4 53.7 6.09 80.9 80.9 80.9 71.2 61.5 51.9 Temperature of Air on Condenser Coil 105°F 7.38 58.4 52.8 47.3 41.7 36.2 7.12 63.9 63.9 63.0 57.5 51.9 46.4 6.93 60.9 60.9 60.9 55.3 49.8 44.2 6.95 59.5 59.5 59.5 54.0 48.4 42.8 7.63 58.8 52.3 45.7 39.1 32.5 7.36 68.7 65.1 60.9 54.4 47.8 41.2 7.16 66.9 66.9 65.8 59.3 52.7 46.1 7.19 65.3 65.3 64.7 58.1 51.5 45.0 7.87 59.3 51.7 44.1 36.5 28.9 7.61 73.6 66.4 58.8 51.2 43.6 36.1 7.39 72.8 72.8 70.8 63.2 55.6 48.1 7.42 71.2 71.2 69.9 62.3 54.7 47.1 7.91 64.9 56.3 47.7 39.0 30.4 7.64 77.0 72.0 63.6 54.9 46.3 37.7 7.43 74.7 74.7 73.7 65.1 56.4 47.8 7.46 73.0 73.0 72.3 63.7 55.1 46.4 7.95 70.6 60.9 51.2 41.5 31.8 7.68 80.3 77.5 68.3 58.6 48.9 39.2 7.47 76.6 76.6 76.6 66.9 57.2 47.5 7.50 74.8 74.8 74.8 65.1 55.5 45.8 Temperature of Air on Condenser Coil 125°F 8.82 52.4 46.8 41.3 35.7 30.2 8.44 57.0 57.0 56.0 50.4 44.9 39.3 8.26 55.5 55.5 55.5 49.9 44.3 38.8 8.30 54.2 54.2 54.2 48.6 43.1 37.5 9.12 54.1 47.6 41.0 34.4 27.8 8.72 61.7 59.8 55.5 49.0 42.4 35.8 8.53 60.1 60.1 58.7 52.1 45.5 38.9 8.58 58.7 58.7 58.3 51.7 45.1 38.6 9.41 55.8 48.3 40.7 33.1 25.5 9.00 66.4 62.7 55.1 47.5 40.0 32.4 8.81 64.7 64.7 61.9 54.3 46.7 39.1 8.86 63.2 63.2 62.4 54.8 47.2 39.6 9.49 61.1 52.5 43.9 35.2 26.6 9.08 67.8 67.4 59.5 50.8 42.2 33.5 8.88 66.1 66.1 64.7 56.0 47.4 38.8 8.93 64.6 64.6 64.2 55.5 46.9 38.3 9.56 66.4 56.8 47.1 37.4 27.7 9.15 69.3 69.3 63.8 54.1 44.4 34.7 8.95 67.5 67.5 67.5 57.8 48.1 38.4 9.00 65.9 65.9 65.9 56.3 46.6 36.9 Johnson Controls Unitary Products 68 Tot. Cap.* (MBH) 47.8 43.9 42.4 40.0 45.4 44.8 32.3 46.9 47.2 32.5 45.5 44.7 32.7 44.0 42.2 73.5 67.3 63.6 62.2 81.2 74.4 70.3 68.7 88.9 81.4 76.9 75.2 91.4 83.6 79.0 77.2 93.8 85.9 81.1 79.3 40.8 38.6 37.3 34.6 39.6 38.4 28.5 40.5 39.5 29.0 39.1 37.8 29.6 37.8 36.1 67.2 60.4 58.2 56.9 73.3 65.9 63.5 62.0 79.4 71.4 68.7 67.2 81.3 73.1 70.4 68.8 83.2 74.8 72.0 70.4 33.7 33.2 32.0 29.3 32.4 32.0 24.8 31.5 32.0 24.9 30.1 29.6 25.0 28.7 27.2 Tot. Input† (kW) Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 83 80 77 74 71 6.65 61.4 55.8 50.3 44.7 39.2 6.47 67.3 67.3 66.6 61.0 55.5 49.9 6.26 63.6 63.6 63.6 58.0 52.5 46.9 6.28 62.2 62.2 62.2 56.6 51.0 45.5 6.88 61.2 54.6 48.0 41.5 34.9 6.69 71.6 67.8 63.6 57.1 50.5 43.9 6.47 70.3 70.3 69.4 62.9 56.3 49.7 6.49 68.7 68.7 67.9 61.3 54.7 48.2 7.11 61.0 53.4 45.8 38.2 30.6 6.91 75.8 68.2 60.7 53.1 45.5 37.9 6.69 76.9 76.9 75.3 67.7 60.1 52.5 6.71 75.2 75.2 73.6 66.0 58.4 50.8 7.13 66.8 58.2 49.5 40.9 32.3 6.93 80.8 74.3 65.6 57.0 48.3 39.7 6.71 79.0 79.0 78.2 69.6 60.9 52.3 6.73 77.2 77.2 76.4 67.8 59.2 50.5 7.15 72.7 63.0 53.3 43.6 33.9 6.95 85.9 80.3 70.6 60.9 51.2 41.5 6.72 81.1 81.1 81.1 71.4 61.7 52.0 6.74 79.3 79.3 79.3 69.6 59.9 50.2 Temperature of Air on Condenser Coil 115°F 8.10 55.4 49.8 44.3 38.7 33.2 7.78 60.4 60.4 59.5 54.0 48.4 42.8 7.59 58.2 58.2 58.2 52.6 47.1 41.5 7.63 56.9 56.9 56.9 51.3 45.7 40.2 8.37 56.5 49.9 43.3 36.8 30.2 8.04 65.9 62.5 58.2 51.7 45.1 38.5 7.85 63.5 63.5 62.3 55.7 49.1 42.5 7.88 62.0 62.0 61.5 54.9 48.3 41.8 8.64 57.6 50.0 42.4 34.8 27.2 8.30 71.4 64.5 57.0 49.4 41.8 34.2 8.10 68.7 68.7 66.3 58.8 51.2 43.6 8.14 67.2 67.2 66.1 58.5 50.9 43.4 8.70 63.0 54.4 45.8 37.1 28.5 8.36 73.1 69.7 61.5 52.9 44.2 35.6 8.16 70.4 70.4 69.2 60.5 51.9 43.3 8.19 68.8 68.8 68.3 59.6 51.0 42.3 8.76 68.5 58.8 49.1 39.5 29.8 8.42 74.8 74.8 66.0 56.4 46.7 37.0 8.21 72.0 72.0 72.0 62.3 52.6 43.0 8.25 70.4 70.4 70.4 60.7 51.0 41.3 68 44.3 41.4 39.9 37.3 43.2 41.6 30.3 45.0 43.3 31.1 43.7 41.9 31.8 42.4 40.5 37.3 35.9 34.6 32.0 36.0 35.2 26.6 36.0 35.8 27.0 34.6 33.7 27.3 33.3 31.6 * These capacities are gross ratings. For net capacity, deduct air blower motor, MBH = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. † These ratings include condenser fan motors and the compressor motors but not the supply air blower motor. 11 262874-BTG-C-1208 TABLE 6: COOLING CAPACITY 7-1/2 TON UNIT Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 2550 2625 3000 3375 3750 2550 2625 3000 3375 3750 2550 2625 3000 3375 3750 * † 12 75°F WB (°F) Total Cap.* (MBH) Total† 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 103.7 100.5 98.1 95.6 104.1 100.9 98.6 96.0 104.6 101.3 99.0 96.4 107.0 103.7 101.3 98.7 109.4 106.0 103.6 100.9 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.3 6.3 6.3 6.3 6.4 6.4 6.4 6.4 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 95.9 91.8 86.4 85.7 97.5 93.3 87.9 87.2 99.2 94.9 89.3 88.6 100.4 96.1 90.4 89.7 101.6 97.2 91.5 90.8 7.6 7.5 7.4 7.4 7.6 7.6 7.4 7.4 7.7 7.6 7.5 7.5 7.6 7.6 7.4 7.4 7.6 7.5 7.4 7.4 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 83.8 75.5 70.3 69.3 86.3 77.7 72.4 71.3 88.7 79.9 74.5 73.3 89.9 80.9 75.4 74.3 91.0 81.9 76.4 75.2 8.7 8.7 8.7 8.7 8.9 8.9 8.9 8.9 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 Input (kW) 85°F Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 83 80 58.7 52.3 45.9 77.4 71.0 64.6 98.1 89.7 83.3 95.6 94.8 88.3 63.0 55.5 47.9 82.6 75.0 67.5 98.6 94.4 87.0 96.0 95.6 92.3 67.4 58.6 49.9 87.8 79.1 70.3 99.0 99.0 90.7 96.4 96.4 96.3 71.9 62.0 52.0 94.3 83.3 73.3 101.3 101.3 97.2 98.7 98.7 98.6 76.5 65.3 54.1 100.7 87.5 76.3 103.6 103.6 103.6 100.9 100.9 100.9 95°F 58.2 51.7 45.3 73.8 67.4 60.9 86.4 83.9 77.5 85.7 84.4 78.0 63.4 55.8 48.2 80.0 72.4 64.9 87.9 86.6 82.4 87.2 86.5 83.0 68.7 59.9 51.2 86.3 77.5 68.8 89.3 89.3 87.4 88.6 88.6 88.0 74.1 64.1 54.2 91.8 82.8 72.8 90.4 90.4 89.5 89.7 89.7 89.4 79.6 68.4 57.2 97.2 88.1 76.9 91.5 91.5 91.5 90.8 90.8 90.8 115°F 52.6 46.2 39.7 66.8 60.4 53.9 70.3 68.3 61.9 69.3 68.2 61.8 58.6 51.0 43.4 73.3 66.5 59.0 72.4 71.4 67.7 71.3 70.8 67.5 64.6 55.9 47.1 79.9 72.7 64.0 74.5 74.5 73.4 73.3 73.3 73.3 70.6 60.6 50.7 80.9 77.3 68.8 75.4 75.4 74.9 74.3 74.3 74.3 76.6 65.4 54.2 81.9 81.9 73.6 76.4 76.4 76.4 75.2 75.2 75.2 Sensible Capacity (MBH)* Return Dry Bulb (°F) Total† Total Cap.* Input (MBH) (kW) 77 74 71 68 86 83 39.4 58.2 76.9 81.9 40.3 59.9 79.5 84.8 41.1 61.6 82.0 87.6 42.0 63.4 87.2 88.6 42.9 65.2 92.4 89.7 33.0 51.8 70.5 75.5 32.7 52.3 71.9 77.2 32.4 52.8 73.3 78.8 32.1 53.4 77.2 78.7 31.8 54.0 81.2 78.5 45.4 64.1 69.1 44.7 64.3 69.6 44.1 64.5 70.1 43.5 67.3 68.7 42.8 70.0 67.3 38.9 57.7 62.7 37.1 56.7 62.0 35.3 55.8 61.3 33.5 57.3 58.7 31.6 58.9 56.2 99.8 96.1 92.3 90.7 100.8 97.1 93.2 91.6 101.9 98.1 94.2 92.5 103.7 99.9 95.9 94.2 105.5 101.6 97.5 95.8 6.9 6.9 6.8 6.8 6.9 6.9 6.8 6.8 7.0 6.9 6.9 6.8 7.0 6.9 6.9 6.9 7.0 6.9 6.9 6.9 58.4 75.6 92.3 90.7 63.2 81.3 93.2 91.6 68.0 87.1 94.2 92.5 73.0 93.0 95.9 94.2 78.0 99.0 97.5 95.8 52.0 69.2 86.8 89.6 55.6 73.7 90.5 91.1 59.3 78.3 94.2 92.5 63.1 83.1 95.9 94.2 66.8 87.8 97.5 95.8 38.9 54.5 71.0 71.6 40.7 57.3 74.9 75.4 42.4 60.0 78.7 79.3 44.2 62.9 79.5 79.4 46.0 65.7 80.3 79.6 32.5 48.1 64.6 65.1 33.1 49.7 67.3 67.8 33.7 51.3 69.9 70.5 34.3 52.9 69.5 69.5 34.8 54.5 69.2 68.5 41.7 58.2 58.7 42.1 59.7 60.2 42.5 61.2 61.8 43.0 59.6 59.5 43.4 58.0 57.3 35.3 51.8 52.3 34.5 52.1 52.7 33.8 52.4 53.0 33.0 49.6 49.6 32.2 46.8 46.1 89.9 83.6 78.4 77.5 91.9 85.5 80.1 79.3 94.0 87.4 81.9 81.0 95.1 88.5 82.9 82.0 96.3 89.6 83.9 83.0 8.1 8.1 8.0 8.0 8.3 8.2 8.2 8.2 8.4 8.3 8.3 8.3 8.4 8.3 8.3 8.3 8.3 8.3 8.2 8.2 55.4 70.3 78.4 77.5 61.0 76.7 80.1 79.3 66.6 83.1 81.9 81.0 72.4 86.3 82.9 82.0 78.1 89.6 83.9 83.0 48.9 63.9 76.1 76.3 53.4 69.5 79.0 78.6 57.9 75.1 81.9 81.0 62.4 80.1 82.9 82.0 66.9 85.0 83.9 83.0 33.3 47.5 55.5 55.4 35.9 51.4 60.1 60.0 38.4 55.2 64.7 64.5 40.7 58.8 64.9 64.3 43.1 62.5 65.2 64.1 26.9 41.1 49.1 49.0 28.3 43.8 52.5 52.4 29.6 46.5 55.9 55.8 30.8 48.9 55.0 54.3 31.9 51.3 54.0 52.9 34.7 42.7 42.5 36.2 44.9 44.8 37.7 47.2 47.0 38.9 45.0 44.4 40.1 42.8 41.7 28.3 36.3 36.1 28.6 37.3 37.2 29.0 38.4 38.3 29.0 35.0 34.4 28.9 31.7 30.5 77.8 67.3 62.3 61.1 80.7 69.8 64.7 63.4 83.5 72.3 67.0 65.7 84.6 73.3 67.9 66.6 85.7 74.3 68.8 67.4 9.2 9.3 9.3 9.3 9.5 9.5 9.6 9.6 9.8 9.8 9.9 9.9 9.8 9.8 9.9 9.9 9.8 9.9 9.9 9.9 49.8 63.3 62.3 61.1 56.2 69.8 64.7 63.4 62.6 72.3 67.0 65.7 68.9 73.3 67.9 66.6 75.1 74.3 68.8 67.4 43.4 56.9 60.6 60.1 48.6 63.6 63.8 62.9 53.9 70.3 67.0 65.7 58.9 73.3 67.9 66.6 64.0 74.3 68.8 67.4 80 45.6 62.8 80.4 83.2 48.1 66.2 84.7 87.7 50.5 69.6 89.1 92.2 53.1 73.1 93.3 94.0 55.7 76.6 97.5 95.8 105°F 42.5 57.4 69.7 69.9 45.8 61.9 75.1 75.3 49.1 66.4 80.4 80.6 52.4 70.8 82.2 81.8 55.7 75.3 83.9 83.0 125°F 36.9 50.5 54.1 53.7 41.0 56.0 60.3 59.8 45.1 61.6 66.4 65.7 48.9 66.8 67.6 66.6 52.8 72.0 68.8 67.4 77 74 71 68 39.2 56.4 74.0 76.7 40.5 58.6 77.2 80.1 41.8 60.8 80.3 83.4 43.1 63.1 83.4 84.0 44.5 65.4 86.4 84.7 32.8 49.9 67.6 70.3 32.9 51.0 69.6 72.5 33.0 52.1 71.6 74.7 33.2 53.2 73.4 74.1 33.3 54.3 75.2 73.5 43.5 61.1 63.9 43.4 62.0 64.9 43.3 62.8 65.9 43.2 63.4 64.1 43.1 64.0 62.3 37.1 54.7 57.5 35.8 54.4 57.3 34.6 54.1 57.2 33.2 53.5 54.1 31.9 52.8 51.1 36.1 51.0 63.3 63.5 38.3 54.3 67.5 67.7 40.4 57.6 71.7 71.9 42.5 60.9 72.2 71.9 44.5 64.1 72.8 71.8 29.7 44.6 56.9 57.0 30.7 46.7 59.9 60.1 31.6 48.9 62.9 63.1 32.5 50.9 62.3 61.9 33.4 52.9 61.6 60.7 38.2 50.4 50.6 39.2 52.3 52.5 40.1 54.2 54.4 40.9 52.3 51.9 41.7 50.4 49.5 31.8 44.0 44.2 31.6 44.7 44.9 31.4 45.4 45.7 31.0 42.3 42.0 30.6 39.2 38.3 30.5 44.0 47.7 47.3 33.4 48.4 52.7 52.2 36.4 52.8 57.7 57.2 39.0 56.8 57.6 56.7 41.6 60.8 57.6 56.3 24.1 37.6 41.3 40.9 25.9 40.8 45.1 44.6 27.6 44.1 48.9 48.4 29.0 46.9 47.7 46.7 30.4 49.7 46.4 45.1 31.2 34.9 34.5 33.3 37.5 37.1 35.3 40.2 39.7 36.9 37.7 36.8 38.5 35.3 33.9 24.8 28.5 28.0 25.7 29.9 29.5 26.6 31.4 30.9 26.9 27.8 26.8 27.3 24.1 22.7 The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 7: COOLING CAPACITY 8-1/2 TON UNIT Air On Evap. Coil WB CFM (°F) 2550 2975 3400 3825 4250 Temperature of Air on Condenser Coil 85°F Tot. Tot. Cap.* Input† (MBH) (kW) 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 109.7 104.5 105.0 95.9 112.6 107.3 107.7 98.4 115.5 110.0 110.5 100.9 118.2 112.6 113.1 103.3 120.9 115.2 115.7 105.7 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 103.1 93.5 86.8 85.3 106.6 96.6 89.7 88.2 110.0 99.7 92.6 91.0 112.8 102.2 94.9 93.3 115.6 104.8 97.2 95.6 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 91.7 78.8 73.5 68.7 95.6 82.2 76.6 71.7 99.4 85.5 79.8 74.6 102.1 87.8 81.9 76.6 104.7 90.1 84.0 78.6 8.06 7.96 7.97 7.86 8.10 8.00 8.01 7.90 8.14 8.04 8.05 7.94 8.16 8.06 8.07 7.96 8.18 8.09 8.09 7.98 Temperature of Air on Condenser Coil 95°F Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 66.4 83.8 84.3 95.9 72.4 91.0 91.6 98.4 78.5 98.3 98.8 100.9 84.6 105.6 106.2 103.3 90.8 112.9 113.5 105.7 83 80 77 74 71 68 59.1 51.8 44.5 37.3 76.6 69.3 62.0 54.7 47.5 40.2 77.1 69.8 62.5 55.2 48.0 40.7 95.9 89.2 81.9 74.6 67.4 60.1 63.8 55.2 46.6 38.1 82.5 73.9 65.3 56.7 48.1 39.5 83.0 74.4 65.8 57.2 48.6 40.0 98.4 95.1 86.5 77.9 69.3 60.7 68.6 58.7 48.7 38.8 88.4 78.4 68.5 58.6 48.7 38.8 88.9 79.0 69.1 59.2 49.3 39.3 100.9 100.9 91.0 81.1 71.2 61.3 73.4 62.1 50.8 39.5 94.3 83.0 71.7 60.4 49.1 37.8 94.9 83.6 72.3 61.0 49.7 38.4 103.3 103.3 92.0 80.7 69.4 58.1 78.1 65.5 52.8 40.1 100.2 87.5 74.9 62.2 49.5 36.9 100.8 88.2 75.5 62.8 50.2 37.5 105.7 105.7 93.0 80.3 67.7 55.0 Tot. Tot. Cap.* Input† (MBH) (kW) 108.8 100.8 93.4 93.6 112.1 103.8 96.2 96.4 115.3 106.8 99.0 99.2 118.2 109.5 101.4 101.6 121.0 112.1 103.8 104.1 8.75 8.61 8.40 8.44 8.83 8.68 8.47 8.51 8.90 8.76 8.55 8.58 8.97 8.83 8.61 8.65 9.05 8.90 8.68 8.72 Temperature of Air on Condenser Coil 105°F 2550 2975 3400 3825 4250 9.45 9.21 9.00 9.04 9.53 9.28 9.08 9.11 9.61 9.36 9.15 9.19 9.67 9.43 9.22 9.25 9.74 9.49 9.28 9.32 63.0 79.6 86.8 85.3 69.9 87.6 89.7 88.2 76.8 95.5 92.6 91.0 83.2 100.1 94.9 93.3 89.5 104.8 97.2 95.6 55.7 72.3 84.4 84.4 61.3 79.4 88.5 87.7 66.9 86.4 92.6 91.0 71.9 92.6 94.9 93.3 76.9 98.8 97.2 95.6 48.5 65.1 77.1 77.1 52.7 70.8 83.8 83.8 56.9 76.5 90.5 90.5 60.6 81.3 93.9 93.1 64.2 86.2 97.2 95.6 41.2 57.8 69.8 69.8 44.1 62.2 75.2 75.2 47.0 66.5 80.6 80.6 49.3 70.0 82.6 81.8 51.5 73.5 84.6 82.9 33.9 50.5 62.6 62.6 35.5 53.6 66.6 66.6 37.1 56.6 70.7 70.7 38.0 58.7 71.3 70.5 38.9 60.9 71.9 70.3 43.3 55.3 55.3 45.0 58.0 58.0 46.7 60.8 60.8 47.5 60.0 59.2 48.2 59.2 57.6 Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 83 80 77 74 71 68 65.1 82.6 93.4 93.6 71.7 90.5 96.2 96.4 78.3 98.5 99.0 99.2 84.4 105.3 101.4 101.6 90.5 112.1 103.8 104.1 57.9 75.3 90.2 92.3 63.1 81.9 94.6 95.7 68.4 88.5 99.0 99.2 73.1 94.4 101.4 101.6 77.8 100.2 103.8 104.1 50.6 68.0 82.9 85.0 54.5 73.3 89.3 91.6 58.5 78.6 95.8 98.2 61.8 83.1 99.8 101.2 65.1 87.5 103.8 104.1 43.3 60.8 75.6 77.7 45.9 64.7 80.8 83.0 48.6 68.7 85.9 88.3 50.5 71.8 88.5 89.9 52.4 74.9 91.2 91.4 36.1 53.5 68.4 70.4 37.4 56.1 72.2 74.4 38.6 58.8 76.0 78.4 39.2 60.5 77.2 78.6 39.8 62.2 78.5 78.8 46.2 61.1 63.2 47.6 63.6 65.8 48.9 66.1 68.5 49.2 65.9 67.3 49.5 65.8 66.1 39.0 53.8 55.9 -A 39.0 55.0 57.2 39.0 56.1 58.5 37.9 54.7 56.0 36.9 53.2 53.4 Temperature of Air on Condenser Coil 115°F 36.0 48.0 48.0 36.4 49.5 49.4 36.8 50.9 50.8 36.2 48.7 47.9 35.5 46.6 44.9 97.4 86.1 80.1 77.0 101.1 89.4 83.1 79.9 104.7 92.6 86.2 82.8 107.4 95.0 88.4 85.0 110.2 97.4 90.6 87.1 10.15 9.81 9.61 9.64 10.23 9.89 9.68 9.72 10.31 9.96 9.76 9.80 10.37 10.03 9.82 9.86 10.44 10.09 9.88 9.92 60.9 76.6 80.1 77.0 68.0 84.6 83.1 79.9 75.2 92.6 86.2 82.8 81.9 95.0 88.4 85.0 88.6 97.4 90.6 87.1 53.6 69.4 78.6 76.5 59.5 76.8 82.4 79.7 65.3 84.2 86.2 82.8 70.6 90.8 88.4 85.0 76.0 97.4 90.6 87.1 46.3 62.1 71.3 69.2 50.9 68.2 78.3 76.0 55.4 74.3 85.3 82.8 59.3 79.6 88.0 85.0 63.3 84.9 90.6 87.1 39.1 54.8 64.0 62.0 42.3 59.6 69.7 67.4 45.5 64.4 75.4 72.9 48.1 68.3 76.7 73.7 50.6 72.2 78.0 74.4 31.8 47.6 56.8 54.7 33.7 51.0 61.1 58.8 35.6 54.5 65.5 63.0 36.8 57.0 65.4 62.4 38.0 59.5 65.3 61.8 40.3 49.5 47.4 42.4 52.5 50.2 44.5 55.6 53.1 45.7 54.1 51.1 46.8 52.6 49.1 33.0 42.2 40.2 33.8 43.9 41.6 34.6 45.6 43.1 34.4 42.8 39.8 34.2 39.9 36.4 Temperature of Air on Condenser Coil 125°F 2550 2975 3400 3825 4250 10.85 10.41 10.21 10.24 10.93 10.49 10.29 10.32 11.01 10.57 10.37 10.40 11.07 10.62 10.42 10.46 11.13 10.68 10.48 10.51 58.7 73.7 73.5 68.7 66.2 81.7 76.6 71.7 73.7 85.5 79.8 74.6 80.7 87.8 81.9 76.6 87.7 90.1 84.0 78.6 Johnson Controls Unitary Products 51.5 66.4 72.8 68.6 57.6 74.2 76.3 71.6 63.8 82.0 79.8 74.6 69.4 87.8 81.9 76.6 75.0 90.1 84.0 78.6 44.2 59.1 65.5 61.4 49.0 65.6 72.8 68.2 53.9 72.1 79.8 74.6 58.1 77.8 81.9 76.6 62.4 83.5 84.0 78.6 36.9 51.9 58.3 54.1 40.4 57.0 64.2 59.6 44.0 62.2 70.1 65.2 46.8 66.5 70.7 65.6 49.7 70.8 71.3 65.9 29.6 44.6 51.0 46.8 31.8 48.4 55.6 51.0 34.0 52.3 60.2 55.3 35.5 55.2 59.4 54.3 37.0 58.2 58.7 53.3 37.3 43.7 39.5 39.8 47.0 42.5 42.4 50.3 45.4 43.9 48.2 43.0 45.5 46.0 40.6 30.1 36.4 32.3 31.3 38.4 33.9 32.5 40.4 35.4 32.6 36.9 31.7 32.8 33.3 27.9 * These capacities are gross ratings. For net capacity, deduct air blower motor, MBH = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. † These ratings include condenser fan motors and the compressor motors but not the supply air blower motor. 13 262874-BTG-C-1208 TABLE 8: COOLING CAPACITY 10 TON UNIT Air On Evap. Coil CFM 3000 3500 4000 4500 5000 3000 3500 4000 4500 5000 3000 3500 4000 4500 5000 14 WB (°F) Temperature of Air on Condenser Coil 85°F Tot. Cap.* (MBH) 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 137 126 116 117 141 130 120 120 145 133 123 123 145 133 123 124 146 134 124 124 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 127 113 103 105 130 116 106 107 133 119 108 110 133 119 108 110 133 119 108 110 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 107 91 82 82 111 95 86 85 116 98 89 89 115 98 89 88 114 97 88 88 Temperature of Air on Condenser Coil 95°F Sensible Capacity (MBH)* Return Dry Bulb (°F) Tot. † Tot. 71 68 Cap. (MBH) 9.7 79 71 62 54 45 9.5 100 91 83 74 66 57 9.3 116 110 101 93 84 75 9.2 117 113 104 96 87 79 9.8 87 77 67 57 47 9.5 110 100 89 79 69 59 9.3 120 116 109 99 89 79 9.3 120 118 113 103 93 83 9.8 96 84 72 61 49 9.6 120 108 96 85 73 61 9.4 123 123 118 106 94 83 9.3 123 123 122 110 98 87 9.9 101 87 74 61 48 9.7 125 112 99 86 72 59 9.5 123 123 121 107 94 81 9.4 124 124 123 110 96 83 10.0 106 91 76 61 46 9.7 131 116 101 86 72 57 9.5 124 124 124 109 94 79 9.5 124 124 124 109 95 80 Temperature of Air on Condenser Coil 105°F 11.2 74 66 57 49 40 10.8 93 85 76 68 59 51 10.5 103 100 91 82 74 65 10.5 105 100 92 83 75 66 11.3 83 73 63 52 42 10.9 103 94 84 73 63 53 10.6 106 104 100 89 79 69 10.6 107 105 100 90 80 70 11.4 91 80 68 56 45 11.0 113 102 91 79 67 56 10.7 108 108 108 96 85 73 10.7 110 110 109 98 86 74 11.5 98 85 71 58 45 11.1 116 108 95 82 69 55 10.8 108 108 108 95 82 68 10.7 110 110 109 96 83 70 11.5 104 90 75 60 45 11.1 119 113 100 85 70 55 10.8 108 108 108 93 78 63 10.8 110 110 110 95 80 65 Temperature of Air on Condenser Coil 125°F 12.7 68 59 51 42 34 11.9 85 76 68 59 51 42 11.5 82 81 73 64 56 47 11.6 82 81 73 64 56 47 12.8 77 67 56 46 36 12.1 94 86 75 65 55 45 11.6 86 85 81 71 61 51 11.8 85 85 81 71 61 51 13.0 86 74 62 51 39 12.2 99 95 83 71 60 48 11.8 89 89 89 78 66 54 11.9 89 89 89 78 66 55 13.1 92 79 66 53 39 12.4 98 98 88 75 61 48 11.9 89 89 89 75 62 49 12.0 88 88 88 75 62 49 13.2 99 84 70 55 40 12.5 97 97 93 78 63 48 12.0 88 88 88 73 58 43 12.1 88 88 88 73 58 43 48 67 70 49 69 73 50 71 75 46 68 70 42 64 65 137 124 114 116 139 126 116 118 141 129 117 120 142 129 118 120 142 129 118 121 42 57 58 43 59 60 44 61 62 42 55 56 40 49 50 117 102 93 93 120 105 96 96 124 108 99 99 124 108 98 99 123 108 98 99 Input (kW) 86 83 80 77 74 33 38 39 35 41 41 36 43 43 35 36 36 33 29 28 Sensible Capacity (MBH)* Return Dry Bulb (°F) Tot. * † Input (kW) 71 68 10.4 78 69 61 52 43 10.2 98 89 81 72 64 55 10.0 114 109 100 92 83 74 9.9 116 110 101 93 84 76 10.5 86 76 66 56 46 10.3 108 98 88 78 67 57 10.1 116 113 109 99 89 78 10.0 118 115 110 100 90 80 10.6 94 83 71 59 48 10.4 118 106 95 83 71 60 10.2 117 117 117 106 94 82 10.1 120 120 119 107 96 84 10.6 101 87 74 61 48 10.4 124 112 99 85 72 59 10.2 118 118 118 105 91 78 10.1 120 120 120 107 93 80 10.6 107 92 77 62 47 10.5 129 118 103 88 73 58 10.2 118 118 118 103 88 73 10.1 121 121 121 106 91 76 Temperature of Air on Condenser Coil 115°F 11.9 71 62 54 45 37 11.4 89 81 72 63 55 46 11.0 93 90 82 73 65 56 11.0 93 91 82 74 65 57 12.1 80 70 60 49 39 11.5 99 90 79 69 59 49 11.1 96 95 90 80 70 60 11.2 96 95 91 81 71 61 12.2 88 77 65 53 42 11.6 109 99 87 75 64 52 11.2 99 99 99 87 75 64 11.3 99 99 99 88 76 64 12.3 95 82 69 55 42 11.7 108 103 92 78 65 52 11.3 98 98 98 85 72 59 11.4 99 99 99 86 73 59 12.4 102 87 72 57 42 11.8 108 108 96 81 66 51 11.4 98 98 98 83 68 53 11.5 99 99 99 84 69 54 86 83 80 77 74 46 66 67 47 68 70 48 71 72 46 65 67 43 59 61 38 48 48 39 50 50 40 52 53 38 45 46 37 39 39 * These capacities are gross ratings. For net capacity, deduct air blower motor, MBH = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. † These ratings include condenser fan motors and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 9: COOLING CAPACITY 12-1/2 TON UNIT Air On Evap. Coil CFM 3750 4375 5000 5625 6250 3750 4375 5000 5625 6250 3750 4375 5000 5625 6250 WB (°F) Temperature of Air on Condenser Coil 85°F Tot. Cap.* (MBH) 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 165 152 141 139 170 157 145 143 175 162 149 147 176 162 150 148 177 163 151 149 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 147 133 122 125 151 136 125 128 155 140 129 131 156 141 130 133 158 142 131 134 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 127 112 102 111 129 114 104 113 132 116 106 115 133 118 107 116 135 119 109 117 Temperature of Air on Condenser Coil 95°F Sensible Capacity (MBH)* Return Dry Bulb (°F) Tot. † Tot. 71 68 Cap. (MBH) 12.2 97 86 75 64 54 11.9 123 112 101 91 80 69 11.6 141 136 125 114 104 93 11.3 139 136 125 115 104 93 12.2 107 94 82 69 57 12.0 136 123 110 98 85 72 11.7 145 142 136 123 111 98 11.4 143 142 136 124 111 98 12.3 118 103 88 74 59 12.0 148 134 119 105 90 75 11.8 149 149 147 133 118 103 11.5 147 148 148 133 118 104 12.4 125 109 92 76 59 12.1 156 141 124 108 91 74 11.9 150 150 149 132 116 99 11.6 148 148 148 132 115 99 12.5 133 115 96 77 59 12.2 163 148 129 111 92 73 12.0 151 151 151 132 114 95 11.7 149 149 149 131 112 93 Temperature of Air on Condenser Coil 105°F 14.8 90 79 69 58 47 14.4 115 104 93 83 72 61 14.1 122 119 108 97 87 76 14.2 125 121 110 100 89 78 14.9 101 88 75 63 50 14.5 126 115 102 90 77 64 14.2 125 124 118 106 93 80 14.3 128 126 121 108 96 83 15.0 111 96 82 67 53 14.6 136 126 111 97 82 68 14.3 129 129 129 114 100 85 14.4 131 131 131 117 102 88 15.2 120 103 87 70 54 14.8 139 132 118 102 85 68 14.4 130 130 130 113 97 80 14.5 133 133 133 116 99 83 15.3 129 110 92 73 55 14.9 142 138 125 106 88 69 14.6 131 131 131 112 94 75 14.7 134 134 134 115 96 78 Temperature of Air on Condenser Coil 125°F 17.7 83 72 62 51 40 17.2 108 97 86 76 65 54 16.8 102 100 89 78 68 57 17.1 111 107 96 85 75 64 17.8 93 80 68 55 42 17.3 114 107 95 82 69 57 17.0 104 103 98 85 72 60 17.2 113 111 105 93 80 67 17.9 103 88 74 59 44 17.4 117 117 103 88 74 59 17.1 106 106 106 92 77 62 17.4 115 115 115 100 85 71 18.1 114 97 81 64 48 17.6 118 118 113 96 80 63 17.2 107 107 107 91 74 58 17.5 116 116 116 99 83 66 18.2 125 107 88 69 51 17.7 119 119 119 104 86 67 17.3 109 109 109 90 71 53 17.6 117 117 117 98 80 61 58 82 82 60 86 86 61 89 89 58 83 82 55 76 75 157 143 132 132 162 147 136 136 167 151 140 140 168 152 141 141 169 154 142 142 51 65 67 52 68 70 53 70 73 52 63 66 50 56 59 137 122 112 118 140 125 115 120 143 128 117 123 145 129 119 124 146 131 120 125 Input (kW) Johnson Controls Unitary Products 86 83 80 77 74 43 46 53 44 47 55 45 48 56 46 41 49 48 34 43 Sensible Capacity (MBH)* Return Dry Bulb (°F) Tot. * † Input (kW) 86 83 80 77 74 13.4 93 83 72 61 51 13.1 118 108 97 86 76 12.8 132 128 117 107 96 12.8 132 128 117 107 96 13.5 104 92 79 66 54 13.1 132 119 106 94 81 12.9 136 134 129 116 103 12.9 136 134 129 116 103 13.6 115 100 86 71 57 13.2 145 130 116 101 86 13.0 140 140 140 125 111 12.9 140 140 140 125 111 13.7 123 106 90 73 57 13.3 149 137 121 104 88 13.1 141 141 141 124 108 13.0 141 141 141 124 108 13.8 131 112 94 75 56 13.4 154 145 126 107 89 13.2 142 142 142 123 105 13.2 142 142 142 123 105 Temperature of Air on Condenser Coil 115°F 16.3 87 76 65 55 44 15.8 111 100 90 79 68 15.5 112 109 98 88 77 15.7 118 114 103 92 82 16.4 97 84 71 59 46 15.9 120 111 98 86 73 15.6 115 113 108 95 83 15.8 120 118 113 100 88 16.5 107 92 78 63 49 16.0 128 122 107 93 78 15.7 117 117 117 103 88 15.9 123 123 123 108 94 16.6 117 100 84 67 51 16.2 129 126 116 99 82 15.8 119 119 119 102 85 16.0 124 124 124 108 91 16.7 127 109 90 71 53 16.3 131 131 124 105 87 16.0 120 120 120 101 82 16.2 125 125 125 107 88 71 68 65 85 85 68 91 91 72 96 96 71 91 91 70 86 86 54 75 75 56 78 78 57 82 82 54 75 75 51 67 67 58 66 71 61 70 75 63 74 79 66 69 74 68 64 70 47 56 60 48 57 63 49 59 65 49 52 58 49 45 51 * These capacities are gross ratings. For net capacity, deduct air blower motor, MBH = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. † These ratings include condenser fan motors and the compressor motors but not the supply air blower motor. 15 262874-BTG-C-1208 TABLE 10: HEATING APPLICATION DATA 6-1/2 TON UNIT OUTDOOR TEMPERATURE (°F) (72% RH) CFM ID DB CAP & kW -10 0 10 20 30 40 50 60 MBH 7.579 15.506 23.432 31.359 39.286 47.212 55.139 63.066 KW 3.882 4.020 4.158 4.296 4.434 4.573 4.711 4.849 MBH 12.565 20.491 28.418 36.345 44.271 52.198 60.125 68.051 KW 4.713 4.851 4.989 5.127 5.265 5.404 5.542 5.680 MBH 13.299 21.226 29.152 37.079 45.005 52.932 60.859 68.785 KW 5.273 5.411 5.549 5.687 5.825 5.964 6.102 6.240 MBH 13.381 21.308 29.235 37.161 45.088 53.015 60.941 68.868 KW 3.525 3.663 3.801 3.939 4.077 4.216 4.354 4.492 MBH 18.336 26.263 34.190 42.116 50.043 57.970 65.896 73.823 KW 4.347 4.485 4.623 4.761 4.899 5.038 5.176 5.314 MBH 19.094 27.021 34.948 42.874 50.801 58.728 66.654 74.581 KW 4.914 5.052 5.190 5.328 5.466 5.605 5.743 5.881 MBH 12.452 20.379 28.305 36.232 44.158 52.085 60.012 67.938 KW 3.272 3.410 3.548 3.686 3.824 3.963 4.101 4.239 MBH 17.438 25.364 33.291 41.218 49.144 57.071 64.997 72.924 KW 4.103 4.241 4.379 4.517 4.655 4.794 4.932 5.070 MBH 18.172 26.098 34.025 41.952 49.878 57.805 65.732 73.658 KW 4.663 4.801 4.939 5.077 5.215 5.354 5.492 5.630 55 1950 70 80 55 2600 70 80 55 3250 70 80 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 x KW) 16 Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 11: HEATING APPLICATION DATA 7-1/2 TON UNIT OUTDOOR TEMPERATURE (°F) (72% RH) CFM ID DB CAP & kW -10 0 10 20 30 40 50 60 MBH 19.558 31.733 43.909 56.084 68.259 80.435 92.610 104.786 KW 4.285 4.748 5.211 5.674 6.138 6.601 7.064 7.528 MBH 13.542 25.718 37.893 50.068 62.244 74.419 86.595 98.770 KW 4.759 5.223 5.686 6.149 6.613 7.076 7.539 8.002 MBH 8.519 20.694 32.869 45.045 57.220 69.396 81.571 93.746 KW 5.065 5.528 5.992 6.455 6.918 7.382 7.845 8.308 MBH 23.523 35.699 47.874 60.049 72.225 84.400 96.576 108.751 KW 4.299 4.762 5.225 5.689 6.152 6.615 7.079 7.542 MBH 17.508 29.683 41.858 54.034 66.209 78.385 90.560 102.736 KW 4.774 5.237 5.700 6.164 6.627 7.090 7.553 8.017 MBH 12.484 24.660 36.835 49.010 61.186 73.361 85.537 97.712 KW 5.079 5.543 6.006 6.469 6.933 7.396 7.859 8.322 MBH 22.703 34.878 47.054 59.229 71.404 83.580 95.755 107.931 KW 3.990 4.453 4.917 5.380 5.843 6.307 6.770 7.233 MBH 16.687 28.863 41.038 53.213 65.389 77.564 89.740 101.915 KW 4.465 4.928 5.391 5.855 6.318 6.781 7.245 7.708 MBH 11.664 23.839 36.014 48.190 60.365 72.541 84.716 96.891 KW 4.771 5.234 5.697 6.160 6.624 7.087 7.550 8.014 55 2250 70 80 55 3000 70 80 55 3750 70 80 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 x KW) Johnson Controls Unitary Products 17 262874-BTG-C-1208 TABLE 12: HEATING APPLICATION DATA 8-1/2 TON UNIT OUTDOOR TEMPERATURE (°F) (72% RH) CFM ID DB CAP & kW -10 0 10 20 30 40 50 60 MBH 17.316 31.627 45.938 60.248 74.559 88.870 103.180 117.491 KW 4.697 5.365 6.033 6.700 7.368 8.035 8.703 9.371 MBH 13.315 27.626 41.937 56.247 70.558 84.869 99.179 113.490 KW 5.336 6.004 6.672 7.339 8.007 8.674 9.342 10.010 MBH 9.862 24.173 38.484 52.794 67.105 81.416 95.726 110.037 KW 5.627 6.295 6.963 7.630 8.298 8.965 9.633 10.301 MBH 21.927 36.238 50.549 64.859 79.170 93.481 107.791 122.102 KW 4.696 5.364 6.032 6.699 7.367 8.034 8.702 9.370 MBH 17.926 32.237 46.548 60.858 75.169 89.480 103.790 118.101 KW 5.335 6.003 6.671 7.338 8.006 8.673 9.341 10.009 MBH 14.473 28.784 43.095 57.405 71.716 86.027 100.337 114.648 KW 5.626 6.294 6.962 7.629 8.297 8.964 9.632 10.300 MBH 25.263 39.574 53.885 68.195 82.506 96.817 111.127 125.438 KW 5.080 5.748 6.416 7.083 7.751 8.418 9.086 9.754 MBH 21.262 35.573 49.884 64.194 78.505 92.816 107.126 121.437 KW 5.719 6.387 7.055 7.722 8.390 9.057 9.725 10.393 MBH 17.809 32.120 46.431 60.741 75.052 89.363 103.673 117.984 KW 6.010 6.678 7.346 8.013 8.681 9.348 10.016 10.684 55 2550 70 80 55 3400 70 80 55 4250 70 80 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 x KW) 18 Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 13: HEATING APPLICATION DATA 10 TON UNIT OUTDOOR TEMPERATURE (°F) (72% RH) CFM ID DB CAP & kW -10 0 10 20 30 40 50 60 MBH 17.601 32.584 47.567 62.549 77.532 92.515 107.498 122.480 KW 5.642 6.082 6.522 6.962 7.401 7.841 8.281 8.721 MBH 18.204 33.187 48.170 63.152 78.135 93.118 108.101 123.083 KW 6.590 7.030 7.469 7.909 8.349 8.789 9.228 9.668 MBH 15.834 30.817 45.800 60.782 75.765 90.748 105.731 120.713 7.118 7.558 7.997 8.437 8.877 9.317 9.756 10.196 MBH 18.040 33.023 48.006 62.989 77.971 92.954 107.937 122.920 KW 5.215 5.655 6.095 6.535 6.974 7.414 7.854 8.294 MBH 18.643 33.626 48.609 63.592 78.574 93.557 108.540 123.523 KW 6.163 6.603 7.042 7.482 7.922 8.362 8.801 9.241 MBH 16.273 31.256 46.239 61.222 76.204 91.187 106.170 121.153 KW 6.691 7.131 7.570 8.010 8.450 8.890 9.329 9.769 MBH 16.305 31.287 46.270 61.253 76.236 91.218 106.201 121.184 KW 5.090 5.530 5.970 6.410 6.849 7.289 7.729 8.169 MBH 16.908 31.890 46.873 61.856 76.839 91.821 106.804 121.787 KW 6.038 6.478 6.917 7.357 7.797 8.237 8.676 9.116 MBH 14.538 29.520 44.503 59.486 74.469 89.451 104.434 119.417 KW 6.566 7.006 7.445 7.885 8.325 8.765 9.204 9.644 55 3000 70 80 KW 55 4000 70 80 55 5000 70 80 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 x KW) Johnson Controls Unitary Products 19 262874-BTG-C-1208 TABLE 14: HEATING APPLICATION DATA 12-1/2 TON UNIT OUTDOOR TEMPERATURE (°F) (72% RH) CFM ID DB CAP & kW -10 0 10 20 30 40 50 60 MBH 36.258 51.135 66.012 80.889 95.766 110.643 125.520 140.397 KW 7.766 8.115 8.465 8.814 9.164 9.513 9.863 10.212 MBH 42.599 57.476 72.353 87.230 102.107 116.984 131.861 146.738 KW 9.412 9.761 10.111 10.460 10.810 11.159 11.509 11.858 MBH 42.807 57.684 72.561 87.438 102.315 117.192 132.069 146.946 KW 10.598 10.947 11.297 11.646 11.996 12.345 12.695 13.044 MBH 38.088 52.965 67.842 82.719 97.596 112.473 127.350 142.226 KW 6.971 7.320 7.670 8.019 8.369 8.718 9.068 9.417 MBH 44.429 59.306 74.183 89.060 103.937 118.814 133.691 148.567 KW 8.617 8.966 9.316 9.665 10.015 10.364 10.714 11.063 MBH 44.637 59.514 74.391 89.268 104.145 119.022 133.899 148.775 KW 9.803 10.152 10.502 10.851 11.201 11.550 11.900 12.249 MBH 35.195 50.072 64.949 79.826 94.703 109.580 124.457 139.334 KW 6.033 6.382 6.732 7.081 7.431 7.780 8.130 8.479 MBH 41.536 56.413 71.290 86.167 101.044 115.921 130.798 145.675 KW 7.679 8.028 8.378 8.727 9.077 9.426 9.776 10.125 MBH 41.744 56.621 71.498 86.375 101.252 116.129 131.006 145.883 KW 8.865 9.214 9.564 9.913 10.263 10.612 10.962 11.311 55 3750 70 80 55 5000 70 80 55 6250 70 80 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 x KW) 20 Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 15: ELECTRICAL DATA BA-06 (6-1/2 TON) HP W/O PWRD CONVENIENCE OUTLET Supply Pwr Pwr Min. Circuit Blower Exh Conv Ampacity Electric Heater Actual Heater Voltage Motor FLA Motor Outlet (Amps) Model No. KW Amps RLA LRA FLA 1.5 2 1.5 2 FLA FLA ea. ea. ea. HP HP HP HP None --33.0 35.0 2TP04520925 6.8 18.9 56.6 58.6 18.9 146.0 1.6 6.2 8.2 5.5 0.0 208 2TP04521825 13.5 37.5 79.9 81.9 2TP04522425 18.0 50.0 95.5 97.5 2TP04523625 25.5 70.8 121.5 123.5 None --33.0 35.0 2TP04520925 9.0 21.7 60.1 62.1 18.9 146.0 1.6 6.2 8.2 5.5 0.0 230 2TP04521825 18.0 43.3 87.2 89.2 2TP04522425 24.0 57.7 105.2 107.2 2TP04523625 34.0 81.8 135.3 137.3 None --16.6 17.6 2TP04520946 9 11.3 30.1 31.1 9.5 73.0 0.8 3.1 4.1 2.2 0.0 460 2TP04521846 18 22.6 43.6 44.6 2TP04522446 24 30.1 52.7 53.7 2TP04523646 34 42.7 67.7 68.7 None --13.1 14.3 2TP04520958 9 9.0 23.9 25.1 7.6 58.4 0.6 2.4 3.6 1.8 0.0 575 2TP04521858 18 18.1 34.8 36 2TP04522458 24 24.1 42 43.2 2TP04523658 34 34.1 54 55.2 * Maximum HACR breaker of the same AMP size is applicable. Compressors OD Fan Motors MCA w/Power Exhaust (Amps) 1.5 2 HP HP 38.5 40.5 62.1 64.1 85.4 87.4 101.0 103.0 127.0 129.0 38.5 40.5 65.6 67.6 92.7 94.7 110.7 112.7 140.8 142.8 18.8 19.8 32.3 33.3 45.8 46.8 54.9 55.9 69.9 70.9 14.9 16.1 25.7 26.9 36.6 37.8 43.8 45 55.8 57 Max Max Fuse* Size Fuse* w/Power Size Exhaust (Amps) (Amps) 1.5 2 1.5 2 HP HP HP HP 45 45 50 50 70 70 70 70 80 90 90 90 100 100 110 110 125 125 150 150 45 45 50 50 70 70 70 80 90 90 100 100 110 110 125 125 150 150 150 150 25 25 25 25 35 35 35 40 45 45 50 50 60 60 60 60 70 70 70 80 20 20 20 20 25 30 30 30 35 40 40 40 45 45 45 45 60 60 60 60 TABLE 16: ELECTRICAL DATA BA-06 (6-1/2 TON) HP WITH PWRD CONVENIENCE OUTLET Pwr Supply Pwr Blower Exh Conv Electric Heater Actual Heater Voltage Motor FLA Motor Outlet KW Amps Model No. RLA LRA FLA 1.5 2 FLA FLA ea. ea. ea. HP HP None --2TP04520925 6.8 18.9 18.9 146.0 1.6 6.2 8.2 5.5 10.0 208 2TP04521825 13.5 37.5 2TP04522425 18.0 50.0 2TP04523625 25.5 70.8 None --2TP04520925 9.0 21.7 18.9 146.0 1.6 6.2 8.2 5.5 10.0 230 2TP04521825 18.0 43.3 2TP04522425 24.0 57.7 2TP04523625 34.0 81.8 None --2TP04520946 9 11.3 73.0 0.8 3.1 9.5 4.1 2.2 5.0 460 2TP04521846 18 22.6 2TP04522446 24 30.1 2TP04523646 34 42.7 None --2TP04520958 9 9.0 7.6 58.4 0.6 2.4 3.6 1.8 4.0 575 2TP04521858 18 18.1 2TP04522458 24 24.1 2TP04523658 34 34.1 * Maximum HACR breaker of the same AMP size is applicable. Compressors OD Fan Motors Johnson Controls Unitary Products Min. Circuit Ampacity (Amps) 1.5 HP 43.0 66.6 89.9 105.5 131.5 43.0 70.1 97.2 115.2 145.3 21.6 35.1 48.6 57.7 72.7 17.1 27.9 38.8 46 58 2 HP 45.0 68.6 91.9 107.5 133.5 45.0 72.1 99.2 117.2 147.3 22.6 36.1 49.6 58.7 73.7 18.3 29.1 40 47.2 59.2 MCA w/Power Exhaust (Amps) 1.5 2 HP HP 48.5 50.5 72.1 74.1 95.4 97.4 111.0 113.0 137.0 139.0 48.5 50.5 75.6 77.6 102.7 104.7 120.7 122.7 150.8 152.8 23.8 24.8 37.3 38.3 50.8 51.8 59.9 60.9 74.9 75.9 18.9 20.1 29.7 30.9 40.6 41.8 47.8 49 59.8 61 Max Max Fuse* Size Fuse* w/Power Size Exhaust (Amps) (Amps) 1.5 2 1.5 2 HP HP HP HP 60 60 60 60 80 80 80 80 90 100 100 100 110 110 125 125 150 150 150 150 60 60 60 60 80 80 80 90 100 100 110 110 125 125 125 125 150 150 175 175 30 30 30 30 40 40 40 45 50 50 60 60 60 60 60 70 80 80 80 80 20 25 25 25 30 30 35 35 40 40 45 45 50 50 50 50 60 60 60 70 21 262874-BTG-C-1208 TABLE 17: ELECTRICAL DATA BA-07 (7-1/2 TON) HP W/O PWRD CONVENIENCE OUTLET Compressors Voltage RLA ea. LRA ea. OD Fan Motors FLA ea. MCA Max Fuse Min. Circuit Max Fuse* Pwr Pwr w/Power Size Ampacity Size Exh Conv Electric Exhaust w/Power Actual Heater (Amps) (Amps) Motor Outlet Heater Model (Amps) Exhaust KW Amps No. 3 HP FLA FLA 2 HP 3 HP 2 HP 3 HP 2 HP 3 HP 2 HP 3 HP Supply Blower Motor FLA 2 HP 208 11.5 84.0 1.5 8.2 10.9 5.5 0.0 230 11.5 84.0 1.5 8.2 10.9 5.5 0.0 460 6.4 42.0 0.8 4.1 5.3 2.2 0.0 575 5.1 34.0 0.6 3.6 4.1 1.8 0.0 None 2TP04540925 2TP04541825 2TP04542425 2TP04543625 None 2TP04540925 2TP04541825 2TP04542425 2TP04543625 None 2TP04540946 2TP04541846 2TP04542446 2TP04543646 None 2TP04540958 2TP04541858 2TP04542458 2TP04543658 -6.8 13.5 18 25.5 -9 18 24 34 -9 18 24 34 -9 18 24 34 -18.9 37.5 50.0 70.8 -21.7 43.3 57.7 81.8 -11.3 22.6 30.1 42.7 -9.0 18.1 24.1 34.1 37.1 60.7 83.9 99.5 125.6 37.1 64.1 91.2 109.2 139.3 20.1 33.6 47.2 56.2 71.2 16.3 27.1 37.9 45.1 57.2 39.8 63.4 86.6 102.2 128.3 39.8 66.8 93.9 111.9 142.0 21.3 34.8 48.4 57.4 72.4 16.8 27.6 38.4 45.6 57.7 42.6 66.2 89.4 105.0 131.1 42.6 69.6 96.7 114.7 144.8 22.3 35.8 49.4 58.4 73.4 18.1 28.9 39.7 46.9 59 45.3 68.9 92.1 107.7 133.8 45.3 72.3 99.4 117.4 147.5 23.5 37 50.6 59.6 74.6 18.6 29.4 40.2 47.4 59.5 45 70 90 100 150 45 70 100 110 150 25 35 50 60 80 20 30 40 50 60 50 70 90 110 150 50 70 100 125 150 25 35 50 60 80 20 30 40 50 60 50 70 90 110 150 50 70 100 125 150 25 40 50 60 80 20 30 40 50 60 50 70 100 110 150 50 80 100 125 150 25 40 60 60 80 20 30 45 50 60 TABLE 18: ELECTRICAL DATA BA-07 (7-1/2 TON) HP WITH PWRD CONVENIENCE OUTLET Compressors Voltage RLA ea. 22 LRA ea. OD Fan Motors FLA ea. MCA Max Fuse Min. Circuit Max Fuse* Pwr Pwr w/Power Size Ampacity Size Exh Conv Electric Exhaust w/Power Actual Heater (Amps) (Amps) Motor Outlet Heater Model (Amps) Exhaust KW Amps No. 3 HP FLA FLA 2 HP 3 HP 2 HP 3 HP 2 HP 3 HP 2 HP 3 HP Supply Blower Motor FLA 2 HP 208 11.5 84.0 1.5 8.2 10.9 5.5 10.0 230 11.5 84.0 1.5 8.2 10.9 5.5 10.0 460 6.4 42.0 0.8 4.1 5.3 2.2 5.0 575 5.1 34.0 0.6 3.6 4.1 1.8 4.0 None 2TP04540925 2TP04541825 2TP04542425 2TP04543625 None 2TP04540925 2TP04541825 2TP04542425 2TP04543625 None 2TP04540946 2TP04541846 2TP04542446 2TP04543646 None 2TP04540958 2TP04541858 2TP04542458 2TP04543658 -6.8 13.5 18 25.5 -9 18 24 34 -9 18 24 34 -9 18 24 34 -18.9 37.5 50.0 70.8 -21.7 43.3 57.7 81.8 -11.3 22.6 30.1 42.7 -9.0 18.1 24.1 34.1 47.1 70.7 93.9 109.5 135.6 47.1 74.1 101.2 119.2 149.3 25.1 38.6 52.2 61.2 76.2 20.3 31.1 41.9 49.1 61.2 49.8 73.4 96.6 112.2 138.3 49.8 76.8 103.9 121.9 152.0 26.3 39.8 53.4 62.4 77.4 20.8 31.6 42.4 49.6 61.7 52.6 76.2 99.4 115.0 141.1 52.6 79.6 106.7 124.7 154.8 27.3 40.8 54.4 63.4 78.4 22.1 32.9 43.7 50.9 63 55.3 78.9 102.1 117.7 143.8 55.3 82.3 109.4 127.4 157.5 28.5 42 55.6 64.6 79.6 22.6 33.4 44.2 51.4 63.5 50 80 100 110 150 50 80 110 125 150 30 40 60 70 80 25 35 45 50 70 60 80 100 125 150 60 80 110 125 175 30 40 60 70 80 25 35 45 50 70 60 80 100 125 150 60 80 110 125 175 30 45 60 70 80 25 35 45 60 70 60 80 110 125 150 60 90 110 150 175 30 45 60 70 80 25 35 45 60 70 Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 19: ELECTRICAL DATA BA-08 (8-1/2 TON) HP W/O PWRD CONVENIENCE OUTLET Supply Pwr Pwr Blower Exh Conv Electric Heater Actual Heater Voltage Motor FLA Motor Outlet Model No. KW Amps RLA LRA FLA 2 3 FLA FLA ea. ea. ea. HP HP None --2TP04520925 6.8 18.9 14.7 130.0 3.5 8.2 10.9 5.5 0.0 208 2TP04521825 13.5 37.5 2TP04522425 18.0 50.0 2TP04523625 25.5 70.8 None --2TP04520925 9.0 21.7 14.7 130.0 3.5 8.2 10.9 5.5 0.0 230 2TP04521825 18.0 43.3 2TP04522425 24.0 57.7 2TP04523625 34.0 81.8 None --2TP04520946 9 11.3 7.7 64.0 1.6 4.1 5.3 2.2 0.0 460 2TP04521846 18 22.6 2TP04522446 24 30.1 2TP04523646 34 42.7 None --2TP04520958 9 9.0 6.4 52.0 1.3 3.6 4.1 1.8 0.0 575 2TP04521858 18 18.1 2TP04522458 24 24.1 2TP04523658 34 34.1 * Maximum HACR breaker of the same AMP size is applicable. Compressors OD Fan Motors Min. Circuit Ampacity (Amps) 2 HP 48.3 71.9 95.1 110.7 136.8 48.3 75.3 102.4 120.4 150.5 24.6 38.2 51.7 60.7 75.7 20.6 31.4 42.3 49.5 61.5 3 HP 51.0 74.6 97.8 113.4 139.5 51.0 78.0 105.1 123.1 153.2 25.8 39.4 52.9 61.9 76.9 21.1 31.9 42.8 50 62 MCA w/Power Exhaust (Amps) 2 3 HP HP 53.8 56.5 77.4 80.1 100.6 103.3 116.2 118.9 142.3 145.0 53.8 56.5 80.8 83.5 107.9 110.6 125.9 128.6 156.0 158.7 26.8 28 40.4 41.6 53.9 55.1 62.9 64.1 77.9 79.1 22.4 22.9 33.2 33.7 44.1 44.6 51.3 51.8 63.3 63.8 Max Max Fuse* Size Fuse* w/Power Size Exhaust (Amps) (Amps) 2 3 2 3 HP HP HP HP 60 60 60 70 80 80 80 90 100 100 110 110 125 125 125 125 150 150 150 150 60 60 60 70 80 80 90 90 110 110 110 125 125 125 150 150 175 175 175 175 30 30 30 35 40 40 45 45 60 60 60 60 70 70 70 70 80 80 80 80 25 25 25 25 35 35 35 35 45 45 45 45 50 50 60 60 70 70 70 70 TABLE 20: ELECTRICAL DATA BA-08 (8-1/2 TON) HP WITH PWRD CONVENIENCE OUTLET Pwr Pwr Supply Exh Conv Blower Electric Heater Actual Heater Voltage Motor FLA Motor Outlet Model No. KW Amps RLA LRA FLA 2 3 FLA FLA ea. ea. ea. HP HP None --2TP04520925 6.8 18.9 10.0 14.7 130.0 3.5 8.2 10.9 5.5 208 2TP04521825 13.5 37.5 2TP04522425 18.0 50.0 2TP04523625 25.5 70.8 None --2TP04520925 9.0 21.7 14.7 130.0 3.5 8.2 10.9 5.5 10.0 230 2TP04521825 18.0 43.3 2TP04522425 24.0 57.7 2TP04523625 34.0 81.8 None --2TP04520946 9 11.3 7.7 64.0 1.6 4.1 5.3 2.2 5.0 460 2TP04521846 18 22.6 2TP04522446 24 30.1 2TP04523646 34 42.7 None --2TP04520958 9 9.0 6.4 52.0 1.3 3.6 4.1 1.8 4.0 575 2TP04521858 18 18.1 2TP04522458 24 24.1 2TP04523658 34 34.1 * Maximum HACR breaker of the same AMP size is applicable. OD Fan Compressors Motors Johnson Controls Unitary Products Min. Circuit Ampacity (Amps) 2 HP 58.3 81.9 105.1 120.7 146.8 58.3 85.3 112.4 130.4 160.5 29.6 43.2 56.7 65.7 80.7 24.6 35.4 46.3 53.5 65.5 3 HP 61.0 84.6 107.8 123.4 149.5 61.0 88.0 115.1 133.1 163.2 30.8 44.4 57.9 66.9 81.9 25.1 35.9 46.8 54 66 MCA w/Power Exhaust (Amps) 2 3 HP HP 63.8 66.5 87.4 90.1 110.6 113.3 126.2 128.9 152.3 155.0 63.8 66.5 90.8 93.5 117.9 120.6 135.9 138.6 166.0 168.7 31.8 33 45.4 46.6 58.9 60.1 67.9 69.1 82.9 84.1 26.4 26.9 37.2 37.7 48.1 48.6 55.3 55.8 67.3 67.8 Max Max Fuse* Size Fuse* w/Power Size Exhaust (Amps) (Amps) 2 3 2 3 HP HP HP HP 70 70 70 80 90 90 90 100 110 110 125 125 125 125 150 150 150 150 175 175 70 70 70 80 90 90 100 100 125 125 125 125 150 150 150 150 175 175 175 175 35 35 35 40 45 45 50 50 60 60 60 70 70 70 70 70 90 90 90 90 30 30 30 30 40 40 40 40 50 50 50 50 60 60 60 60 70 70 70 70 23 262874-BTG-C-1208 TABLE 21: ELECTRICAL DATA BA-10 (10 TON) HP W/O POWERED CONVENIENCE OUTLET MCA Max Max Fuse Size* Supply Pwr Pwr Min. Circuit w/Power Fuse* w/Power Blower Exh Conv Ampacity Electric Heater Actual Heater Exhaust Size Exhaust Voltage Motor FLA Motor Outlet (Amps) Model No. KW Amps (Amps) (Amps) (Amps) RLA LRA FLA 2 3 2 3 2 3 2 3 2 3 FLA FLA ea. ea. ea. HP HP HP HP HP HP HP HP HP HP None --51.2 53.9 56.7 59.4 60 60 70 70 2TP04521825 13.5 37.5 98.0 100.7 103.5 106.2 100 110 110 110 16.0 150.0 3.5 8.2 10.9 5.5 0.0 208 2TP04522425 18.0 50.0 113.7 116.4 119.2 121.9 125 125 125 125 2TP04523625 25.5 70.8 139.7 142.4 145.2 147.9 150 150 150 150 2HP04525425** 40.6 112.7 151.1 154.5 158.0 161.4 175 175 175 175 None --51.2 53.9 56.7 59.4 60 60 70 70 2TP04521825 18.0 43.3 105.3 108.0 110.8 113.5 110 110 125 125 16.0 150.0 3.5 8.2 10.9 5.5 0.0 230 2TP04522425 24.0 57.7 123.4 126.1 128.9 131.6 125 150 150 150 2TP04523625 34.0 81.8 153.4 156.1 158.9 161.6 175 175 175 175 2HP04525425** 54.0 129.9 153.4 156.1 158.9 161.6 175 175 175 175 None --29.6 30.8 31.8 33 35 40 40 40 2TP04521846 18 22.6 56.6 57.8 58.8 60 60 60 60 60 9.9 75.0 1.6 4.1 5.3 2.2 0.0 460 2TP04522446 24 30.1 65.7 66.9 67.9 69.1 70 70 70 70 2TP04523646 34 42.7 80.7 81.9 82.9 84.1 90 90 90 90 2HP04535446** 54 67.8 80.7 81.9 82.9 84.1 90 90 90 90 None --20.6 21.1 22.4 22.9 25 25 25 25 2TP04521858 18 18.1 42.3 42.8 44.1 44.6 45 45 45 45 6.4 62.0 1.3 3.6 4.1 1.8 0.0 575 2TP04522458 24 24.1 49.5 50 51.3 51.8 50 50 60 60 2TP04523658 34 34.1 61.5 62 63.3 63.8 70 70 70 70 2HP04535458** 54 54.2 61.5 62 63.3 63.8 70 70 70 70 * Maximum HACR breaker of the same AMP size is applicable. ** Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are locked-out. OD Fan Compressors Motors TABLE 22: ELECTRICAL DATA BA-10 (10 TON) HP WITH POWERED CONVENIENCE OUTLET MCA Max Max Fuse* Size Pwr Pwr Min. Circuit Supply w/Power Fuse* w/Power Exh Conv Ampacity Blower Electric Heater Actual Heater Exhaust Size Exhaust Voltage (Amps) Motor FLA Motor Outlet Model No. KW Amps (Amps) (Amps) (Amps) RLA LRA FLA 2 3 2 3 2 3 2 3 2 3 FLA FLA ea. ea. ea. HP HP HP HP HP HP HP HP HP HP None --61.2 63.9 66.7 69.4 70 70 80 80 2TP04521825 13.5 37.5 108.0 110.7 113.5 116.2 110 125 125 125 16.0 150.0 3.5 8.2 10.9 5.5 10.0 208 2TP04522425 18.0 50.0 123.7 126.4 129.2 131.9 125 150 150 150 2TP04523625 25.5 70.8 149.7 152.4 155.2 157.9 150 175 175 175 2HP04525425** 40.6 112.7 163.6 167.0 170.5 173.9 175 175 175 175 None --61.2 63.9 66.7 69.4 70 70 80 80 2TP04521825 18.0 43.3 115.3 118.0 120.8 123.5 125 125 125 125 16.0 150.0 3.5 8.2 10.9 5.5 10.0 230 2TP04522425 24.0 57.7 133.4 136.1 138.9 141.6 150 150 150 150 2TP04523625 34.0 81.8 163.4 166.1 168.9 171.6 175 175 175 175 2HP04525425** 54.0 129.9 163.4 166.1 168.9 171.6 175 175 175 175 None --34.6 35.8 36.8 38 40 45 45 45 2TP04521846 18 22.6 61.6 62.8 63.8 65 70 70 70 70 9.9 75.0 1.6 4.1 5.3 2.2 5.0 460 2TP04522446 24 30.1 70.7 71.9 72.9 74.1 80 80 80 80 2TP04523646 34 42.7 85.7 86.9 87.9 89.1 90 90 90 90 2HP04535446** 54 67.8 85.7 86.9 87.9 89.1 90 90 90 90 None --24.6 25.1 26.4 26.9 30 30 30 30 2TP04521858 18 18.1 46.3 46.8 48.1 48.6 50 50 50 50 6.4 62.0 1.3 3.6 4.1 1.8 4.0 575 2TP04522458 24 24.1 53.5 54 55.3 55.8 60 60 60 60 2TP04523658 34 34.1 65.5 66 67.3 67.8 70 70 70 70 2HP04535458** 54 54.2 65.5 66 67.3 67.8 70 70 70 70 * Maximum HACR breaker of the same AMP size is applicable. ** Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are locked-out. Compressors 24 OD Fan Motors Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 23: ELECTRICAL DATA BA-12 (12-1/2 TON) HP W/O POWERED CONVENIENCE OUTLET Max Max Fuse* Size MCA Min. Circuit Pwr Pwr Supply w/Power w/Power Fuse* Ampacity Exh Conv Blower Electric Heater Actual Heater Exhaust Exhaust Size Voltage (Amps) Motor FLA Motor Outlet KW Amps Model No. (Amps) (Amps) (Amps) RLA LRA FLA 3 5 3 5 3 5 3 5 3 5 FLA FLA ea. ea. ea. HP HP HP HP HP HP HP HP HP HP None --60.4 65.6 65.9 71.1 70 80 80 90 2TP04521825 13.5 37.5 107.3 112.5 112.8 118.0 110 125 125 125 208 18.9 146.0 3.5 10.9 16.1 5.5 0.0 2TP04522425 18.0 50.0 122.9 128.1 128.4 133.6 125 150 150 150 2TP04523625 25.5 70.8 148.9 154.1 154.4 159.6 150 175 175 175 2HP04535425** 40.6 112.7 154.5 161.0 161.4 167.9 175 175 175 175 None --60.4 65.6 65.9 71.1 70 80 80 90 2TP04521825 18.0 43.3 114.6 119.8 120.1 125.3 125 125 125 150 230 18.9 146.0 3.5 10.9 16.1 5.5 0.0 2TP04522425 24.0 57.7 132.6 137.8 138.1 143.3 150 150 150 150 2TP04523625 34.0 81.8 162.7 167.9 168.2 173.4 175 175 175 175 2HP04535425** 54.0 129.9 162.7 167.9 168.2 173.4 175 175 175 175 None --29.9 32.7 32.1 34.9 35 40 40 40 2TP04521846 18 22.6 56.9 59.7 59.1 61.9 60 60 60 70 460 9.5 73.0 1.6 5.3 8.1 2.2 0.0 2TP04522446 24 30.1 66 68.8 68.2 71 70 70 70 80 2TP04523646 34 42.7 81 83.8 83.2 86 90 90 90 90 2HP04535446** 54 67.8 81 83.8 83.2 86 90 90 90 90 None --23.8 25.7 25.6 27.5 30 30 30 35 2TP04521858 18 18.1 45.5 47.4 47.3 49.2 50 50 50 50 575 7.6 58.4 1.3 4.1 6.0 1.8 0.0 2TP04522458 24 24.1 52.7 54.6 54.5 56.4 60 60 60 60 2TP04523658 34 34.1 64.7 66.6 66.5 68.4 70 70 70 70 2HP04535458** 54 54.2 64.7 66.6 66.5 68.4 70 70 70 70 * Maximum HACR breaker of the same AMP size is applicable. ** Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are locked-out. OD Fan Compressors Motors TABLE 24: ELECTRICAL DATA BA-12 (12-1/2 TON) HP WITH POWERED CONVENIENCE OUTLET Max Max Fuse* Size MCA Supply Pwr Min. Circuit Pwr w/Power Fuse* w/Power Blower Ampacity Exh Conv Electric Heater Actual Heater Size Exhaust Exhaust Voltage Motor FLA Motor Outlet (Amps) KW Amps Model No. (Amps) (Amps) (Amps) RLA LRA FLA 3 5 3 5 3 5 3 5 3 5 FLA FLA ea. ea. ea. HP HP HP HP HP HP HP HP HP HP None --70.4 75.6 75.9 81.1 80 90 90 100 2TP04521825 13.5 37.5 117.3 122.5 122.8 128.0 125 125 125 150 18.9 146.0 3.5 10.9 16.1 5.5 10.0 208 2TP04522425 18.0 50.0 132.9 138.1 138.4 143.6 150 150 150 150 2TP04523625 25.5 70.8 158.9 164.1 164.4 169.6 175 175 175 175 2HP04535425** 40.6 112.7 167.0 173.5 173.9 180.4 175 175 175 200 None --70.4 75.6 75.9 81.1 80 90 90 100 2TP04521825 18.0 43.3 124.6 129.8 130.1 135.3 125 150 150 150 10.0 10.9 16.1 5.5 230 18.9 146.0 3.5 2TP04522425 24.0 57.7 142.6 147.8 148.1 153.3 150 150 150 175 2TP04523625 34.0 81.8 172.7 177.9 178.2 183.4 175 200 200 200 2HP04535425** 54.0 129.9 172.7 177.9 178.2 183.4 175 200 200 200 None --34.9 37.7 37.1 39.9 40 45 45 45 2TP04521846 18 22.6 61.9 64.7 64.1 66.9 70 70 70 70 9.5 73.0 1.6 5.3 8.1 2.2 5.0 460 2TP04522446 24 30.1 71 73.8 73.2 76 80 80 80 80 2TP04523646 34 42.7 86 88.8 88.2 91 90 90 90 100 2HP04535446** 54 67.8 86 88.8 88.2 91 90 90 90 100 None --27.8 29.7 29.6 31.5 35 35 35 35 2TP04521858 18 18.1 49.5 51.4 51.3 53.2 50 60 60 60 575 58.4 1.3 4.1 6.0 1.8 4.0 7.6 2TP04522458 24 24.1 56.7 58.6 58.5 60.4 60 60 60 70 2TP04523658 34 34.1 68.7 70.6 70.5 72.4 70 80 80 80 2HP04535458** 54 54.2 68.7 70.6 70.5 72.4 70 80 80 80 Maximum HACR breaker of the same AMP size is applicable. * ** Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are locked-out. Compressors OD Fan Motors TABLE 25: ELECTRIC HEAT MULTIPLIERS VOLTAGE NOMINAL 240 480 600 RATING 208 230 460 575 kW Cap. Multiplier 0.75 0.92 0.92 0.92 NOTE: Electric heaters are rated at nominal voltage. Use this table to determine the electric heat capacity for heaters supplied at lower voltages. Johnson Controls Unitary Products NOTES FOR TABLES 26 THROUGH 35: • Blower performance includes dry coil and 2” throwaway filters. ESP (External Static Pressure) given is that available for the supply and return air duct system. All internal resistances have been deducted from the total static pressure of the blower. 25 26 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 ---- ---- ---- ---- ---- 602 612 622 632 642 652 662 672 682 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 949 885 823 764 707 652 600 550 ---- ---- ---- ---- ---- ---- 1.09 1016 1.02 0.95 0.88 0.82 0.76 0.70 0.64 0.59 ---- ---- ---- ---- ---- ---- 776 760 745 730 715 699 684 669 654 639 623 608 ---- ---- ---- 1037 976 917 860 806 755 705 659 614 572 ---- ---- ---- 1.25 1166 1.18 1100 1.11 1.05 0.98 0.92 0.86 0.81 0.76 0.71 0.66 0.61 ---- ---- ---- High Horsepower Option Required ---- 825 815 805 795 786 776 766 756 746 736 727 717 707 697 687 971 923 877 832 790 750 712 676 641 1185 1129 1.40 1305 1.33 1244 1.27 1.21 1.15 1074 1.10 1022 1.04 0.99 0.94 0.89 0.85 0.80 0.76 0.72 0.69 884 876 867 858 850 841 832 824 815 807 798 789 781 772 764 968 922 880 843 810 782 758 1197 1133 1.61 1499 1.52 1417 1.44 1339 1.36 1266 1.28 1.22 1.15 1074 1.09 1019 1.04 0.99 0.94 0.90 0.87 0.84 0.81 944 936 929 921 914 906 899 891 884 876 869 861 854 846 839 997 940 884 1172 1113 1.86 1731 1.79 1666 1.72 1602 1.65 1539 1.58 1476 1.52 1414 1.45 1353 1.39 1292 1.32 1232 1.26 1.19 1.13 1055 1.07 1.01 0.95 987 981 974 967 960 954 947 940 934 927 920 913 907 900 893 996 989 983 976 970 963 957 1.66 1544 1046 1.78 1655 1094 1.96 1827 1.60 1493 1041 1.71 1597 1088 1.90 1770 1.55 1444 1035 1.65 1541 1083 1.84 1713 1.50 1395 1030 1.59 1485 1078 1.78 1656 1.44 1346 1024 1.53 1430 1073 1.71 1599 1.39 1299 1019 1.48 1377 1067 1.65 1541 1.34 1252 1013 1.42 1324 1062 1.59 1484 2.00 1862 1047 2.12 1974 1.92 1793 1041 2.06 1918 1.85 1725 1034 2.00 1862 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1.78 1660 1028 1.94 1807 1073 2.10 1956 1.71 1597 1021 1.88 1753 1068 2.03 1894 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1.65 1537 1015 1.82 1700 1062 1.97 1833 1109 2.14 1999 1.59 1479 1008 1.77 1647 1057 1.90 1773 1104 2.08 1941 1.53 1423 1002 1.71 1595 1051 1.84 1713 1099 2.02 1884 1.47 1369 1.41 1318 1.36 1269 1.31 1223 1.26 1179 1.22 1137 1.18 1097 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 1900 CFM External Static Pressure TABLE 26: 6-1/2 TON SIDE SHOT BLOWER PERFORMANCE 262874-BTG-C-1208 Johnson Controls Unitary Products Johnson Controls Unitary Products 1484 1017 1.52 1421 1082 1.72 1601 1146 1.90 1769 1207 2.06 1923 1267 2.21 2056 1325 2.32 2164 1380 2.49 2320 1434 2.62 2445 2.44 1336 3.28 3058 ---- 2232 2377 2525 2678 2835 2996 3161 3900 1155 2.39 4000 1183 2.55 4100 1211 2.71 4200 1240 2.87 4300 1269 3.04 4400 1299 3.21 4500 1329 3.39 High Horsepower Option Required ---- ---- ------- ------- ---- ------- ---- ------- ---- ---- 1306 3.11 2901 1371 3.32 3091 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1277 2.95 2748 1342 3.15 2939 1406 3.33 3102 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1249 2.79 2600 1314 2.99 2790 1377 3.17 2953 1439 3.32 3097 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1221 2.63 2455 1286 2.84 2645 1349 3.01 2809 1411 3.17 2952 1471 3.31 3081 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1194 2.48 2315 1258 2.69 2505 1322 2.86 2669 1383 3.02 2812 1443 3.15 2941 1501 3.29 3062 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1167 2.27 2113 1232 2.54 2369 1295 2.72 2532 1357 2.87 2676 1416 3.01 2805 1474 3.14 2926 1530 3.27 3046 1583 3.40 3171 2053 ---- 1140 2.13 1990 1205 2.33 2170 1269 2.58 2401 1330 2.73 2544 1390 2.87 2673 1448 3.00 2794 1503 3.13 2914 1556 3.26 3039 3800 1127 2.20 1581 1115 2.01 1870 1179 2.20 2049 1243 2.44 2273 1304 2.59 2416 1364 2.73 2546 1422 2.86 2667 1478 2.99 2787 1531 3.12 2912 1927 1556 1089 1.88 1753 1154 2.07 1932 1218 2.25 2101 1279 2.46 2293 1339 2.60 2422 1397 2.73 2544 1452 2.86 2664 1505 2.99 2789 3700 1101 2.07 1531 1065 1.76 1639 1130 1.95 1819 1193 2.13 1987 1255 2.30 2141 1314 2.47 2304 1372 2.60 2425 1428 2.73 2545 1481 2.86 2670 1804 1507 1041 1.64 1528 1106 1.83 1708 1169 2.01 1877 1231 2.18 2030 1290 2.32 2163 1348 2.48 2311 1404 2.61 2431 1457 2.74 2555 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 3.27 3.14 3.01 2.89 2.77 2.66 2.55 2.34 1418 2.25 2.15 2.06 1.98 1.90 1398 1461 3600 1074 1.94 1342 1359 1378 1.41 1317 1060 1.61 1497 1123 1.79 1666 1185 1.95 1819 1244 2.09 1952 1302 2.21 2060 1358 2.38 2214 1411 2.51 2339 995 1684 999 3300 1.44 1235 996 1.29 1206 1059 1.47 1375 1121 1.64 1528 1181 1.78 1661 1238 1.90 1769 1294 2.06 1922 1347 2.20 2046 1116 1039 1.38 1285 1101 1.54 1438 1161 1.69 1571 1219 1.80 1680 1274 1.97 1832 1327 2.10 1957 1341 1324 1307 1292 1439 3500 1048 1.81 975 3200 1.32 1131 1031 1.20 1117 1090 1.34 1251 1148 1.46 1359 1204 1.62 1508 1257 1.75 1633 1015 1.12 1047 1075 1.27 1180 1133 1.38 1288 1188 1.54 1434 1241 1.67 1559 1.11 1039 1047 1.28 1192 1107 1.42 1325 1164 1.54 1433 1220 1.70 1584 1273 1.83 1709 964 894 1002 1.20 1117 1064 1.36 1270 1124 1.51 1403 1182 1.62 1511 1237 1.78 1664 1290 1.92 1789 985 969 1.03 954 0.96 1.20 1119 1016 1.39 1299 1080 1.58 1468 1141 1.74 1621 1201 1.88 1755 1259 2.00 1863 1314 2.16 2015 1368 2.30 2140 1.10 1026 948 870 795 725 1.11 1030 1020 1.29 1199 1082 1.45 1353 1142 1.59 1486 1200 1.71 1594 1255 1.87 1746 1308 2.01 1871 976 1.20 957 939 1.02 922 0.93 906 0.85 890 0.78 1.30 1216 1038 1.50 1396 1101 1.68 1565 1163 1.84 1718 1222 1.99 1851 1280 2.10 1960 1336 2.27 2113 1389 2.40 2238 973 850 936 1567 951 3100 1.21 1030 931 952 0.91 1.00 3400 1023 1.68 929 3000 1.11 840 933 911 892 1453 907 2900 0.90 1.00 750 664 1.56 865 885 2700 2800 0.81 0.71 768 690 615 545 845 0.82 0.74 0.66 0.58 826 874 857 841 825 2600 582 504 429 359 2500 0.62 0.54 0.46 0.38 808 2 2400 1.8 791 1.6 2300 1.4 1.82 1.2 774 1.0 External Static Pressure 759 0.8 2200 0.6 2100 0.4 BHP 1.74 0.2 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM 2000 745 0.31 292 811 0.51 478 876 0.71 658 939 0.89 827 1001 1.05 980 1061 1.19 1113 1118 1.31 1221 1174 1.46 1361 1227 1.59 1486 1278 CFM TABLE 27: 7-1/2 TON SIDE SHOT BLOWER PERFORMANCE ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 3048 2925 2806 2691 2581 2475 2374 2276 2183 2093 2007 1925 1845 1769 1695 Watts 1622 262874-BTG-C-1208 27 28 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 758 1.39 1300 773 1.47 1369 788 1.55 1443 803 1.63 1520 818 1.72 1602 832 1.81 1687 847 1.91 1777 862 2.01 1870 877 3500 700 1.23 1148 3600 716 1.30 1215 3700 732 1.38 1287 3800 748 1.46 1363 3900 764 1.55 1443 4000 780 1.64 1526 4100 796 1.73 1614 4200 812 1.83 1706 4300 828 1.93 1802 High Horsepower Option Required 2.11 1968 743 1.32 1234 3400 684 1.16 1084 698 1.14 1063 683 1.09 1014 968 728 1.26 1173 ---- 669 1.04 927 ---- 3300 668 1.10 1024 ---- 3100 ---- ---- 654 0.99 ---- ---- 713 1.20 1116 ---- 3000 ---- ---- ---- ---- 968 ---- 2900 ---- ---- ---- 3200 652 1.04 ---- 2800 ---- ---- ---- ---- 2700 ---- ---- ---- 995 920 2.33 2174 907 2.21 2059 894 2.09 1950 882 1.98 1846 869 1.88 1748 856 1.78 1656 843 1.68 1569 831 1.60 1489 818 1.52 1414 805 1.44 1344 792 1.37 1281 780 1.31 1223 767 1.26 1170 754 1.21 1124 741 1.16 1083 729 1.12 1048 716 1.09 1019 703 1.07 2068 1063 2.41 2246 1110 2.72 2539 1987 1056 2.32 2164 1107 2.62 2446 990 2.25 2100 1035 2.40 2239 1076 2.59 2419 1117 2.93 2728 981 2.16 2012 1027 2.31 2152 1070 2.50 2331 1114 2.82 2632 971 2.07 1927 1019 2.22 962 1.98 1845 1011 2.13 1910 1050 2.24 2084 1104 2.53 2356 995 1.97 1836 1043 2.15 2007 1100 2.43 2266 987 1.89 1765 1036 2.07 1933 1097 2.34 2178 979 1.82 1698 1030 2.00 1861 1093 2.24 2091 971 1.75 1634 1023 1.92 1792 1090 2.15 2006 963 1.69 1574 1016 1.85 1726 1086 2.06 1922 955 1.63 1517 1010 1.78 1662 1083 1.97 1840 947 1.57 1464 1003 1.72 1601 1080 1.89 1758 953 1.89 1766 1003 2.05 943 1.81 1691 934 1.74 1618 924 1.66 1549 915 1.59 1482 906 1.52 1419 896 1.46 1359 887 1.40 1302 ---- 967 2.51 2338 1004 2.74 2556 1046 2.89 2694 1083 3.04 2836 1117 3.22 3001 955 2.40 2233 ---- ---- ---- ---- ---- 984 2.49 2321 1028 2.66 2484 1067 2.81 2623 1103 3.00 2796 1131 3.35 3122 974 2.37 2211 1018 2.56 2383 1059 2.71 2522 1096 2.89 2698 1127 3.24 3021 963 2.26 2106 1009 2.45 2286 1051 2.60 2424 1090 2.79 2602 1124 3.13 2922 953 2.15 2005 1000 2.35 2191 1043 2.50 2330 1083 2.69 2509 1121 3.03 2824 943 2.05 1910 933 1.95 1819 922 1.86 1733 912 1.77 1652 902 1.69 1576 892 1.61 1505 882 1.54 1438 871 1.48 1377 861 1.42 1320 851 1.36 1268 841 1.31 1221 831 1.26 1179 994 2.61 2436 1037 2.78 2587 1075 2.93 2728 1110 3.11 2897 942 2.29 2131 930 2.18 2032 918 2.08 1937 906 1.98 1846 893 1.89 1758 881 1.80 1674 869 1.71 1593 856 1.63 1516 844 1.55 1442 832 1.47 1371 820 1.40 1305 807 1.33 1241 795 1.27 1181 783 1.21 1125 771 1.15 1072 758 1.10 1023 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 2600 CFM External Static Pressure TABLE 28: 8-1/2 TON SIDE SHOT BLOWER PERFORMANCE 262874-BTG-C-1208 Johnson Controls Unitary Products 0.2 Johnson Controls Unitary Products 2.32 2.44 707 720 733 746 759 772 784 797 810 823 836 849 862 875 888 901 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 4900 5000 ---- 2503 2387 2274 2166 2061 1960 1863 1770 1680 1595 1513 1435 1361 1290 1224 1161 1102 ---- ---- ---- ---- 971 957 943 929 3.03 2.88 2.74 2.61 2.48 2.35 915 2.23 901 2.12 2.01 1.90 1.80 1.70 1.61 1.53 1.45 1.37 1.30 1.24 1.18 1.13 ---- 887 873 859 845 831 817 803 789 775 761 747 733 719 705 ---- 0.4 0.6 2823 2687 2556 2430 2308 2191 2079 1972 1869 1771 1678 1589 1505 1426 1351 1281 1216 1156 1100 1049 ---- 1021 1007 993 979 965 951 937 923 909 895 881 867 853 839 825 811 797 783 769 755 741 3.32 3.15 3.00 2.85 2.70 2.56 2.43 2.30 2.18 2.07 1.96 1.86 1.76 1.67 1.59 1.51 1.43 1.37 1.31 1.25 1.20 3093 2941 2795 2654 2519 2390 2266 2148 2035 1928 1827 1731 1641 1556 1477 1404 1336 1274 1218 1167 1122 0.8 ---- 1036 1024 1012 1001 989 978 ---- 3.33 3.18 3.04 2.90 2.77 2.64 2.52 2.40 966 2.29 955 2.18 2.07 1.98 1.88 1.79 1.70 1.62 1.55 1.48 1.41 1.35 ---- 3100 2964 2832 2705 2581 2463 2348 2238 2132 2031 1934 1841 1753 1669 1589 1514 1443 1376 1314 1256 ---- ---- 1070 1058 1047 1036 1024 1013 1001 990 979 967 956 944 933 922 910 899 887 876 865 BHP Watts RPM 943 932 920 909 897 886 874 863 851 840 828 816 BHP Watts RPM BHP Watts RPM High Horsepower Option Required 2.69 2.56 2.21 2.10 2.00 1.90 1.80 1.71 1.62 1.54 1.46 1.38 1.31 1.25 1.18 ---- ---- ---- 694 ---- 3200 3400 ---- 3100 ---- 3300 ---- RPM BHP Watts RPM 3000 CFM 1.2 1.4 ---- ---- 3.40 3.25 3.11 2.98 2.85 2.72 2.60 2.48 2.37 2.26 2.15 2.05 1.95 1.86 1.77 1.69 1.61 1.54 1.46 ---- ---- 3166 3032 2902 2776 2654 2536 2422 2311 2205 2103 2005 1911 1821 1735 1653 1575 1501 1431 1365 ---- ---- ---- ---- 1082 1072 1062 1052 1042 1032 ---- ---- ---- ---- 3.41 3.25 3.11 2.96 2.83 2.70 2.58 2.46 1012 1022 2.35 2.24 2.15 2.05 1.97 1.89 1.81 1.75 1.69 1002 992 982 972 962 952 943 933 923 ---- ---- ---- ---- 3175 3032 2895 2763 2637 2516 2402 2293 2190 2092 2001 1915 1834 1760 1691 1628 1571 ---- ---- ---- ---- ---- 1102 1093 1084 1076 1067 1058 1050 1041 1032 ---- ---- ---- ---- ---- 3.42 3.29 3.16 3.04 2.93 2.82 2.71 2.60 2.50 2.41 2.31 1015 1023 2.23 2.14 2.06 1.99 1.91 1006 997 988 980 971 ---- ---- ---- ---- ---- 3184 3065 2949 2838 2729 2625 2524 2427 2334 2244 2158 2076 1997 1922 1851 1784 ---- ---- ---- ---- ---- ---- 1125 1118 1112 1106 1099 1093 1086 1080 1073 1067 1061 1054 1048 1041 1035 BHP Watts RPM BHP Watts RPM BHP Watts RPM 1.0 External Static Pressure TABLE 29: 10 TON SIDE SHOT BLOWER PERFORMANCE 1.6 ---- ---- ---- ---- ---- ---- 3.40 3.28 3.17 3.06 2.95 2.84 2.74 2.64 2.55 2.45 2.37 2.28 2.20 2.12 2.04 ---- ---- ---- ---- ---- ---- 3171 3061 2953 2848 2747 2649 2554 2462 2373 2287 2205 2125 2049 1976 1906 BHP Watts ---- ---- ---- ---- ---- ---- ---- ---- ---- 1147.2 1142.2 1137.2 1132.2 1127.2 1122.2 1117.2 1112.2 ---- ---- ---- ---- ---- ---- ---- ---- ---- 3.38 3.26 3.15 3.04 2.93 2.83 2.72 2.63 2.53 2.44 1107.2 2.35 1102.2 2.26 ---- ---- ---- ---- ---- ---- ---- ---- ---- 3148 3040 2934 2832 2732 2634 2540 2448 2360 2274 2190 2110 BHP Watts 1.8 1097.2 1092.2 RPM 262874-BTG-C-1208 29 30 0.2 0.4 0.6 0.8 1.0 1.2 External Static Pressure 1.4 1.6 1.8 2.0 ---- ---- ---- ---- ---- ---- ---- 822 838 854 870 887 903 919 936 952 968 984 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 4900 5000 5100 5200 5300 5400 5500 ---- ---- ---- ---- ---- ---- ---- ---- 985 968 952 935 918 901 885 868 851 834 ---- ---- ---- ---- ---- 1970 ---- ---- ---- ---- ---- ---- 991 976 961 946 931 915 900 885 870 855 840 ---- 2.96 2.82 2.69 2.57 2.45 2.33 2.22 2.12 2.01 1.92 1.82 3.08 2872 1037 3.38 2.94 2744 1022 3.24 2.81 2622 1007 3.09 2.69 2508 2.58 2401 2.47 2301 2.37 2208 2.28 2121 2.19 2042 2.11 ---- ---- ---- ---- ---- 3.48 3240 1052 3.71 3455 1098 4.01 3.31 3083 1035 3.54 3298 1083 3.85 3.15 2934 1018 3.38 3149 1067 3.69 2.99 2791 1002 3.23 3007 1052 3.53 2.85 2656 2.71 2527 2.58 2406 2.46 2291 2.34 2184 2.23 2083 2.13 1990 ---- ---- ---- ---- ---- ---- ---- ---- ---- 990 975 961 946 932 917 903 888 874 2.70 2.58 2.47 2.37 2.27 2.18 2.09 2.01 1.93 4058 1164 4.58 4224 1178 4.77 4393 1193 4.97 4567 1207 5.18 4745 1222 5.39 4927 1236 5.61 5700 1017 3.83 3574 1085 4.06 3788 1128 4.35 5800 1033 4.02 3751 1102 4.25 3965 1143 4.53 1119 4.45 4149 1159 4.71 5900 1050 4.22 3936 6000 1066 4.43 4127 1136 4.66 4341 1174 4.90 6100 1082 4.64 4326 1152 4.87 4539 1189 5.09 6200 1098 4.86 4531 1169 5.09 4744 1204 5.29 High Horsepower Option Required 3897 1149 4.39 3740 1135 4.20 3587 1120 4.03 3438 1106 3.85 3293 1091 3.69 3152 1077 3.53 3016 1062 3.38 2883 1048 3.23 2755 1033 3.09 2631 1019 2.95 2511 1004 2.82 2395 2283 2175 2072 1973 1877 1786 1699 1113 4.18 5600 1001 3.65 3403 1069 3.88 3618 ---- 3800 996 982 968 954 941 927 997 984 2.36 2.27 2.56 2390 1048 2.79 2.45 2283 1035 2.68 2.34 2182 1022 2.57 2.24 2085 1009 2.46 2.14 1993 2.04 1906 1112 3.43 2113 1037 2.41 1117 3.18 3711 1177 4.20 5231 5027 ---- ------- ------- ---- 4828 1243 5.48 5108 ---- ---- ------- ---- ---- 4635 1229 5.27 4917 1267 5.47 4447 1215 5.07 4731 1254 5.28 4265 1201 4.88 4549 1241 5.08 4089 1188 4.69 4372 1228 4.90 3918 1174 4.51 4200 1215 4.72 3753 1160 4.33 4032 1202 4.54 3593 1147 4.15 3869 1189 4.37 3439 1133 3.98 ---- ---- ---- 5101 ---- ---- ---- ---- ---- ---- ---- ---- 4918 1279 5.42 4740 1267 5.23 4566 1256 5.04 4396 1244 4.86 4231 1233 4.68 4070 1221 4.51 3914 1210 4.34 3763 1198 4.18 3616 1187 4.02 3335 1164 3.72 ---- ---- ---- ---- 5050 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 4872 1293 5.50 5125 4698 1283 5.30 4938 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 4528 1273 5.10 4757 1286 5.41 5044 4363 1262 4.91 4580 1278 5.20 4848 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 4202 1252 4.73 4409 1270 5.00 4660 1317 5.36 4046 1242 4.55 4244 1262 4.80 4477 1308 5.15 3895 1232 4.38 4083 1254 4.61 4301 1300 4.95 3748 1222 4.21 3929 1245 4.43 4131 1291 4.75 3605 1211 4.05 3779 1237 4.26 3967 1282 4.56 3467 1201 3.90 3635 1229 4.09 3810 1273 4.38 3333 1191 3.75 3496 1221 3.93 3659 1265 4.20 3201 1152 3.58 3148 1105 3.66 3409 1151 3.88 1119 3.82 3558 1164 4.04 3462 3080 1171 3.47 3234 1204 3.62 3377 1247 3.87 3111 3204 1181 3.61 3362 1212 3.77 3515 1256 4.03 3473 1175 3.87 3291 3324 1196 3.48 3245 1239 3.71 2960 1160 3.34 ---- ---- ---- ---- ---- ---- ---- ---- ---- 4996 4800 4610 4427 4250 4080 3916 3758 3607 3192 2844 1150 3.21 2993 1188 3.35 3119 1230 3.57 3066 2947 2834 2728 2628 2733 1140 3.09 2881 1179 3.22 3000 1221 3.42 2626 1130 2.98 2774 1171 3.10 2887 1212 3.29 2524 1120 2.87 2672 1163 2.98 2780 1204 3.16 2427 1109 2.76 2576 1155 2.88 2680 1195 3.04 2334 1099 2.67 2485 1146 2.77 2586 1186 2.93 2245 1089 2.57 2399 1138 2.68 2499 1178 2.82 3072 1141 3.44 2948 1129 3.30 2828 2712 1106 3.05 2601 1094 2.93 2494 1083 2.82 2392 1071 2.71 2295 1060 2.60 2202 1048 2.50 3011 1092 3.50 3265 1138 3.73 2879 1078 3.35 3126 1125 3.58 2753 1064 3.21 2991 2633 1051 3.07 2862 1099 3.30 2518 1037 2.94 2736 1087 3.16 2409 1023 2.81 2616 1074 3.03 2305 1009 2.68 2501 1061 2.91 2207 2115 2028 1947 1871 1801 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 3700 CFM TABLE 30: 12-1/2 TON SIDE SHOT BLOWER PERFORMANCE 262874-BTG-C-1208 Johnson Controls Unitary Products 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 801 1.27 1182 813 1.35 1258 825 1.43 1336 836 1.52 1417 ---- 709 801 894 987 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2200 Johnson Controls Unitary Products 2300 2400 2500 2600 2700 728 0.76 2800 739 0.86 2900 750 0.96 3000 761 1.06 3100 772 1.16 1080 3200 784 1.26 1175 3300 795 1.36 1269 ---- ---- 0.9 1.11 1035 964 895 828 763 699 ---- ---- 790 1.19 1107 778 767 1.03 755 0.96 743 732 0.82 720 0.75 ---- ---- High Horsepower Option Required ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2100 ---- ---- ---- ---- ---- ---- 2000 ---- ---- ---0.8 0.9 946 891 839 789 742 698 1.5 1400 890 1.67 1552 879 1.58 1475 868 857 1.42 1327 846 1.35 1257 834 1.28 1190 823 1.21 1125 812 1.14 1063 801 1.08 1003 789 1.01 778 0.96 767 756 0.85 745 733 0.75 0.9 1.1 1030 975 922 872 825 1.3 1211 947 1.85 1721 937 1.76 1640 926 1.68 1562 916 1.59 1487 906 1.52 1414 896 1.44 1344 886 1.37 1276 875 865 1.23 1148 855 1.17 1088 845 835 1.05 824 0.99 814 0.94 804 963 1.4 1.5 1395 1031 1.63 1301 1000 1.56 1454 1036 1.69 993 987 1.43 1336 1025 1.57 980 1.37 1279 1019 1.51 1.6 1491 1019 1.76 1641 1053 1.88 992 1.75 1627 1032 1.9 939 2.05 1908 935 1.96 1827 ---- ---- ---- ---- ---- ---- 931 1.87 1748 1023 2.06 1917 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1769 1045 2.04 1906 927 1.79 1671 1015 1.98 1842 923 1.71 1596 1008 1.9 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1771 1064 2.01 985 1.67 1558 1026 1.83 1705 1059 1.95 977 969 1.53 1426 1013 1.69 1577 1047 1.82 962 1.46 1363 1006 1.63 1515 1042 1.76 954 946 1.33 1240 939 1.27 1181 931 1.21 1124 918 1.63 1523 1000 1.82 1697 1039 1.97 1838 914 1.56 1452 910 1.48 1384 906 1.41 1317 902 1.34 1253 898 1.28 1191 894 1.21 1131 889 1.15 1073 885 1.09 1017 881 1.03 ---- ---- ---- ---- ---- ---- 1878 1816 1755 1695 1636 1578 1521 1465 1409 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 0.2 1900 CFM TABLE 31: 6-1/2 TON DOWN SHOT BLOWER PERFORMANCE 262874-BTG-C-1208 31 32 0.2 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 1.8 980 1739 1861 1986 2114 2314 2473 2636 2806 1.87 3300 1115 3400 1143 2.00 3500 1172 2.13 3600 1201 2.27 3700 1223 2.48 3800 1251 2.65 3900 1280 2.83 4000 1308 3.01 975 890 810 735 979 904 1066 1.21 1129 1138 1.34 1249 1214 1.43 1330 1282 1.69 1574 1364 1.87 1741 1458 2.08 1936 1047 1.13 1054 1120 1.26 1174 1196 1.35 1255 1266 1.60 1492 1349 1.78 1658 1443 1.99 1854 1036 1.23 1143 1106 1.39 1293 1179 1.52 1414 1255 1.60 1495 1317 1.87 1745 1400 2.05 1911 1493 2.26 2107 1015 1.14 1059 1086 1.30 1208 1158 1.43 1329 1234 1.51 1410 1299 1.78 1658 1381 1.96 1824 1475 2.17 2020 995 1.05 977 0.97 1.14 1063 1057 1.32 1232 1128 1.48 1382 1201 1.61 1503 1277 1.70 1584 1337 1.97 1834 1420 2.15 2000 1513 2.36 2196 1.05 0.95 0.87 0.79 1380 3.24 3021 1446 3.43 3201 1351 3.06 2852 1418 3.25 3032 ---- ------- ------- ------- ------- ------- ---- 1323 2.88 2688 1389 3.08 2868 1454 3.24 3023 1519 3.40 3165 ---- ---- ------- ---- ------- ---- ---- 1295 2.71 2530 1361 2.91 2710 1426 3.07 2865 1491 3.23 3007 1560 3.38 3147 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ------- 1267 2.55 2377 1334 2.74 2557 1398 2.91 2713 1464 3.06 2855 1532 3.21 2994 1606 3.37 3142 ---- 1246 2.32 2163 1306 2.59 2411 1371 2.75 2566 1436 2.91 2708 1505 3.06 2848 1579 3.21 2995 1662 3.39 3161 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1218 2.19 2038 1279 2.44 2270 1344 2.60 2426 1409 2.75 2568 1478 2.90 2707 1552 3.06 2854 1635 3.24 3021 1729 3.45 3216 1189 2.06 1916 1261 2.24 2084 1318 2.46 2291 1383 2.61 2433 1451 2.76 2572 1526 2.92 2719 1608 3.10 2886 1702 3.31 3081 1162 1.93 1797 1233 2.11 1965 1304 2.27 2115 1357 2.47 2303 1426 2.62 2443 1500 2.78 2590 1583 2.96 2756 1676 3.17 2952 1134 1.80 1681 1206 1.98 1850 1277 2.15 1999 1349 2.27 2120 1400 2.49 2319 1474 2.65 2467 1557 2.82 2633 1651 3.03 2829 1108 1.68 1569 1179 1.86 1737 1250 2.02 1887 1322 2.15 2008 1399 2.24 2089 1450 2.52 2348 1532 2.70 2515 1626 2.91 2710 1082 1.57 1460 1153 1.75 1629 1224 1.91 1779 1297 2.04 1899 1373 2.12 1980 1425 2.40 2236 1508 2.58 2402 1602 2.79 2598 1057 1.45 1355 1128 1.63 1524 1199 1.80 1674 1271 1.92 1794 1348 2.01 1875 1402 2.28 2128 1485 2.46 2294 1578 2.67 2490 1032 1.35 1254 1104 1.53 1422 1175 1.69 1572 1247 1.82 1693 1323 1.90 1774 1379 2.17 2026 1462 2.35 2192 1556 2.56 2388 1009 1.24 1157 1080 1.42 1325 1151 1.58 1475 1223 1.71 1596 1299 1.80 1677 1358 2.07 1928 1440 2.25 2094 1534 2.46 2290 986 964 943 924 905 High Horsepower Option Required 1620 3200 1087 1.74 1077 1504 982 2800 1.16 1.05 1392 958 2700 798 887 3100 1060 1.61 934 2600 0.86 0.95 3000 1033 1.49 911 2500 713 1178 890 2400 0.77 633 558 1283 869 2300 0.68 0.60 1.26 849 2200 2900 1007 1.38 831 2100 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 2000 814 0.52 488 888 0.71 665 960 0.89 834 1030 1.06 984 1103 1.18 1104 1179 1.27 1185 1253 1.51 1411 1335 1.69 1577 1429 1.90 1773 CFM TABLE 32: 7-1/2 TON DOWN SHOT BLOWER PERFORMANCE 262874-BTG-C-1208 Johnson Controls Unitary Products 0.2 0.4 0.6 0.8 1.0 1.2 External Static Pressure 1.4 1.6 1.8 2.0 Johnson Controls Unitary Products 786 805 824 843 862 881 900 3700 3800 3900 4000 4100 4200 2.16 2.03 1.90 1.79 1.68 1.58 1.49 1.41 1.34 1.28 1.22 1.18 1.14 1.11 ---- ---- ---- ---- ---- ---- 2015 1890 1774 1666 1566 1474 1391 1315 1248 1189 1138 1096 1061 1035 ---- ---- ---- ---- ---- ---- 945 928 911 894 877 860 843 826 809 792 775 758 741 724 706 689 672 655 ---- ---- High Horsepower Option Required 767 690 3100 3600 671 3000 3500 652 2900 748 ---- 2800 3400 ---- 2700 709 ---- 2600 729 ---- 2500 3200 ---- 3300 ---- 2400 999 985 ---- ---- 1178 1128 984 959 1190 1138 1152 1101 1163 1108 1511 1016 1.77 1647 1044 1.88 1.78 1657 1029 1.92 1794 1054 2.03 1.70 1583 1023 1.84 1720 1049 1.95 1.62 1.55 1441 1010 1.69 1577 1039 1.81 1.47 1374 1004 1.62 1508 1034 1.73 2.56 2383 1026 2.76 2571 1058 2.95 2749 1085 3.12 2911 ---- ---- ---- ---- ---- 988 ---- 2.35 2190 ---- 2.42 2257 1014 2.63 2449 1048 2.82 2631 1076 3.00 2797 974 2.21 2063 ---- ---- 2.08 1943 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2.26 2109 1017 2.46 2297 1050 2.65 2473 1076 2.81 2621 ---- ---- 2.15 2005 1007 2.35 2193 1041 2.54 2370 1069 2.71 2522 1090 2.82 2630 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2.04 1902 1015 2.23 2080 1047 2.40 2239 1072 2.53 2361 ---- 2352 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2117 1087 2.32 2165 2194 1092 2.40 2237 1.95 1815 1025 2.12 1976 1053 2.26 2107 1075 2.35 2041 1083 2.25 2093 1.86 1732 1018 2.03 1893 1047 2.17 2026 1070 2.27 1.77 1653 1011 1.94 1812 1041 2.09 1947 1065 2.19 1967 1079 2.17 2023 1894 1074 2.10 1953 1822 1070 2.02 1885 1752 1065 1.95 1817 1683 1061 1.88 1751 1615 1056 1.81 1686 2273 998 996 989 981 974 967 1.69 1576 1003 1.86 1733 1035 2.01 1870 1060 2.11 1.61 1501 1.53 1430 1.46 1362 1.39 1296 1.32 1233 2.04 1900 1032 2.21 2061 1060 2.35 2190 1080 2.44 1.85 1726 990 981 972 964 955 946 938 929 920 1.94 1812 1007 2.13 1989 1040 2.31 2149 1066 2.44 2275 1086 2.52 1.76 1643 1.68 1564 1.60 1488 1.52 1416 1.45 1347 1.38 1282 1.31 1221 1.25 1.19 2.24 2092 1033 2.44 2270 1062 2.60 2425 1084 2.72 2538 997 986 976 966 956 945 935 925 915 904 894 884 874 863 2.14 1995 1024 2.33 2174 1054 2.50 2331 1078 2.63 2449 2.04 1905 1.94 1810 1.84 1719 1.75 1632 1.66 1550 1.58 1473 1.50 1400 1.43 1331 1.36 1267 1.29 1207 1.24 1.18 1.13 1054 1.09 1012 ---- 990 977 965 953 941 929 916 904 892 880 868 856 843 831 819 807 795 2.38 2218 1027 2.58 2405 1059 2.77 2578 1083 2.92 2722 2.17 2023 2.05 1915 1.94 1812 1.84 1715 1.74 1623 1.65 1537 1.56 1456 1.48 1381 1.41 1312 1.34 1248 1.28 1.22 1.17 1091 1.13 1049 1.09 1014 1.06 1.03 2.29 2138 1002 2.50 2331 1038 2.70 2516 1067 2.88 2686 1091 3.03 2825 945 930 916 901 887 872 858 843 829 814 800 785 771 756 742 727 713 959 1.96 1829 1.85 1723 1.74 1624 1.64 1532 1.55 1447 1.47 1369 1.39 1298 1.32 1234 1.26 1.21 1.16 1085 1.13 1050 1.10 1021 1.07 1.06 ---- ---- RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 2300 CFM TABLE 33: 8-1/2 TON DOWN SHOT BLOWER PERFORMANCE 262874-BTG-C-1208 33 34 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 ---- 1.34 1.41 1.49 1.58 1.68 1.79 ---- ---- 3200 3300 3400 748 3500 767 3600 786 3700 805 3800 824 3900 843 2760 1030 3.15 2932 1061 3.32 3094 2934 1047 3.33 3102 1075 3.49 3253 3115 1065 3.52 3278 3305 1082 3.71 3462 2.45 2.61 2.78 2.96 4500 957 4600 976 4700 995 4800 1015 3.15 4900 1034 3.34 5000 1053 3.55 996 979 962 2.14 1995 1024 2.33 2174 1054 2.50 2331 2.24 2092 1033 2.44 2270 1062 2.60 2425 2.38 2218 1027 2.58 2405 1059 2.77 2578 2.56 2383 1026 2.76 2571 1058 2.95 2749 2.80 2614 1032 3.00 2792 1063 3.18 2963 High Horsepower Option Required ---- ------- ------- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2.65 2466 1017 2.84 2650 1050 3.03 2828 1079 3.21 2996 ---- 2.04 1900 1032 2.21 2061 1060 2.35 2190 1.95 1815 1025 2.12 1976 1053 2.26 2107 1.86 1732 1018 2.03 1893 1047 2.17 2026 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2.04 1902 1015 2.23 2080 1047 2.40 2239 1072 2.53 2361 2.49 2324 1003 2.70 2514 1038 2.89 2697 1068 3.08 2871 ---- 998 990 981 1.94 1812 1007 2.13 1989 1040 2.31 2149 1066 2.44 2275 1.85 1726 1.76 1643 1.68 1564 2.26 2109 1017 2.46 2297 1050 2.65 2473 1076 2.81 2621 2595 1013 2.97 2770 1046 3.15 2940 1075 3.33 3103 2437 2288 2148 988 997 986 976 966 956 945 935 2.15 2005 1007 2.35 2193 1041 2.54 2370 1069 2.71 2522 2.04 1905 1.94 1810 1.84 1719 1.75 1632 1.66 1550 1.58 1473 1.50 1400 2.42 2257 1014 2.63 2449 1048 2.82 2631 1076 3.00 2797 2.30 2.35 2190 990 977 965 953 941 929 916 904 892 880 2.29 2138 1002 2.50 2331 1038 2.70 2516 1067 2.88 2686 4400 938 945 974 4300 919 2015 2.21 2063 959 2.17 2023 2.05 1915 1.94 1812 1.84 1715 1.74 1623 1.65 1537 1.56 1456 2.16 928 2.08 1943 945 930 916 901 887 872 858 1.48 1381 1.41 1312 1.34 1248 4200 900 1890 911 1.96 1829 1.85 1723 1.74 1624 1.64 1532 1.55 1447 1.47 1369 1.39 1298 843 829 814 1.90 1774 1178 1128 1.32 1234 1.26 1.21 2.03 894 877 860 843 826 809 792 775 758 741 4100 881 1666 1566 1474 1391 1315 1248 ---- ---- ---- ---- 4000 862 ---- ---- ---- ---- ---- 3100 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 0.2 3000 CFM TABLE 34: 10 TON DOWN SHOT BLOWER PERFORMANCE 262874-BTG-C-1208 Johnson Controls Unitary Products 0.4 0.6 0.8 1.0 1.2 External Static Pressure 1.4 1.6 1.8 2.0 ---- ---- 990 2.34 2183 1036 2.50 2332 1080 2.67 2489 1123 2.84 2652 1165 3.02 2817 1205 3.20 2983 1244 3.38 3149 974 2.23 2077 1020 2.38 2220 1065 2.54 2372 1108 2.71 2530 1151 2.89 2693 1191 3.06 2856 1231 3.24 3021 Johnson Controls Unitary Products 947 2.38 2219 965 2.50 2332 1012 2.67 2491 1056 2.85 2657 1100 3.03 2828 1142 3.22 3001 1183 3.41 3175 1223 3.59 3348 1261 3.78 3520 1298 3.96 3690 983 2.63 2451 1029 2.81 2617 1073 2.99 2788 1116 3.18 2963 1157 3.37 3139 1198 3.56 3315 1237 3.74 3490 1275 3.93 3662 1311 4.11 3832 4300 915 2.34 2184 4400 934 2.46 2294 ---- ---- ---- ---- High Horsepower Option Required ---- ---- ---- ---- ---- ---- ---- ---- ---- 6200 ---- ---- ---- ---- ---- ---- 6100 ---- ---- 6000 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ------- ---- ---- ---- 5800 1197 4.91 4576 1234 5.12 4776 5900 1216 5.14 4792 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 5700 1178 4.69 4368 1216 4.90 4569 1253 5.11 4765 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 5500 1141 4.26 3971 1180 4.48 4175 1218 4.69 4373 1255 4.90 4564 1291 5.10 4750 5600 1160 4.47 4166 1198 4.69 4369 1235 4.90 4566 1271 5.10 4756 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ------- ---- ---- 5400 1122 4.06 3784 1162 4.28 3987 1201 4.49 4185 1238 4.70 4378 1275 4.90 4565 1311 5.09 4745 ---- 5300 1103 3.87 3603 1144 4.08 3805 1184 4.29 4003 1222 4.50 4196 1259 4.70 4384 1296 4.90 4566 1331 5.09 4742 ------- ---- ---- 5200 1084 3.68 3430 1126 3.89 3629 1167 4.11 3827 1205 4.31 4020 1243 4.51 4208 1281 4.71 4391 1317 4.90 4569 1352 5.09 4740 ---- 5100 1066 3.50 3263 1108 3.71 3460 1149 3.92 3656 1189 4.13 3848 1227 4.33 4037 1265 4.53 4221 1302 4.72 4399 1338 4.91 4572 1372 5.09 4740 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 5000 1047 3.33 3103 1090 3.54 3297 1132 3.74 3491 1172 3.95 3682 1211 4.15 3870 1250 4.35 4054 1287 4.54 4233 1323 4.73 4407 1358 4.91 4577 1392 5.09 4744 4900 1028 3.17 2951 1072 3.37 3141 1115 3.57 3331 1156 3.78 3520 1196 3.98 3707 1234 4.17 3891 1272 4.37 4071 1309 4.56 4246 1344 4.74 4417 1379 4.92 4585 4800 1009 3.01 2806 1054 3.21 2990 1098 3.41 3177 1139 3.61 3364 1180 3.81 3549 1219 4.00 3732 1257 4.20 3912 1294 4.39 4088 1330 4.57 4260 1365 4.75 4429 4700 991 2.86 2667 1036 3.05 2846 1081 3.25 3029 1123 3.45 3212 1164 3.64 3396 1204 3.84 3578 1242 4.03 3758 1280 4.22 3933 1316 4.40 4106 1352 4.59 4275 4600 972 2.72 2536 1019 2.91 2708 1063 3.10 2886 1106 3.29 3066 1148 3.48 3247 1188 3.68 3428 1227 3.87 3606 1266 4.06 3782 1303 4.24 3955 1338 4.43 4125 4500 953 2.59 2411 1001 2.76 2577 1046 2.95 2749 1090 3.14 2925 1132 3.33 3103 1173 3.52 3281 1212 3.71 3459 1251 3.90 3634 1289 4.08 3807 1325 4.27 3977 995 2.54 2371 1040 2.72 2531 1084 2.89 2697 1127 3.08 2867 1168 3.26 3039 1208 3.44 3211 1247 3.63 3381 1285 3.81 3550 977 2.42 2256 1023 2.59 2410 1068 2.76 2571 1111 2.94 2737 1153 3.12 2906 1194 3.30 3076 1233 3.48 3245 1271 3.66 3414 929 2.27 2113 960 2.30 2147 1007 2.46 2294 1052 2.63 2449 1096 2.80 2611 1138 2.98 2777 1179 3.16 2945 1219 3.34 3113 1258 3.52 3280 943 2.19 2044 957 2.12 1976 1004 2.27 2112 1050 2.42 2258 1094 2.59 2412 1136 2.76 2571 1177 2.93 2733 1217 3.11 2895 4200 897 2.23 2080 893 2.06 1918 926 2.09 1946 908 1.99 1853 4100 878 2.13 1984 ---- 4000 ---- ---- ---- 875 1.96 1831 911 2.16 2012 ---- 3900 ---- ---- ---- ---- ---- ---- 3800 ---- RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 0.2 3700 ---- CFM TABLE 35: 12-1/2 TON DOWN SHOT BLOWER PERFORMANCE 262874-BTG-C-1208 35 262874-BTG-C-1208 TABLE 36: ADDITIONAL STATIC RESISTANCE 50-3/4" CABINET CFM Cooling Only* Electric Heat KW† Economizer† ‡ 9 18 24 36 54 0.10 1900 0.06 0.02 0.05 0.06 0.07 0.08 2100 0.07 0.02 0.06 0.07 0.08 0.09 0.11 2300 0.08 0.02 0.07 0.08 0.09 0.10 0.13 2500 0.09 0.02 0.08 0.09 0.10 0.11 0.14 2700 0.11 0.03 0.09 0.10 0.12 0.13 0.16 2900 0.12 0.03 0.10 0.11 0.13 0.14 0.18 3100 0.14 0.03 0.12 0.13 0.15 0.16 0.20 3300 0.16 0.03 0.13 0.14 0.17 0.18 0.22 3500 0.18 0.04 0.15 0.16 0.19 0.20 0.24 3700 0.20 0.04 0.17 0.18 0.21 0.22 0.26 3900 0.23 0.04 0.19 0.20 0.23 0.24 0.28 4100 0.25 0.04 0.21 0.22 0.25 0.26 0.31 4300 0.28 0.05 0.23 0.24 0.28 0.29 0.34 4500 0.30 0.05 0.25 0.26 0.30 0.31 0.37 4700 0.33 0.05 0.28 0.29 0.33 0.34 0.40 4900 0.36 0.05 0.30 0.31 0.35 0.37 0.43 5100 0.39 0.06 0.33 0.34 0.38 0.40 0.46 5300 0.42 0.06 0.35 0.37 0.41 0.43 0.49 5500 0.45 0.06 0.38 0.40 0.44 0.46 0.53 5700 0.48 0.06 0.41 0.43 0.47 0.49 0.56 5900 0.52 0.07 0.44 0.46 0.50 0.53 0.59 6100 0.56 0.07 0.47 0.49 0.53 0.56 0.62 6300 0.60 0.07 0.50 0.53 0.56 0.59 0.65 * Add these resistance values to the available static resistance in the respective Blower Performance Tables. † Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. ‡ The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. TABLE 37: ADDITIONAL STATIC RESISTANCE 42" CABINET Electric Heat KW† CFM Cooling Only* Economizer† ‡ 9 18 24 36 54 1900 -0.004 0.07 0.05 0.06 0.07 0.08 0.1 2100 0.01 0.09 0.06 0.07 0.08 0.09 0.11 2300 0.01 0.11 0.07 0.08 0.09 0.1 0.13 2500 0.02 0.13 0.08 0.09 0.1 0.11 0.14 2700 0.03 0.16 0.09 0.1 0.12 0.13 0.16 2900 0.04 0.18 0.1 0.11 0.13 0.14 0.18 3100 0.05 0.20 0.12 0.13 0.15 0.16 0.2 3300 0.06 0.22 0.13 0.14 0.17 0.18 0.22 3500 0.07 0.24 0.15 0.16 0.19 0.2 0.24 3700 0.08 0.27 0.17 0.18 0.21 0.22 0.26 3900 0.09 0.29 0.19 0.2 0.23 0.24 0.28 4100 0.09 0.31 0.21 0.22 0.25 0.26 0.31 4300 0.10 0.33 0.23 0.24 0.28 0.29 0.34 * Add these resistance values to the available static resistance in the respective Blower Performance Tables. † Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. ‡ The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. 36 Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 38: ELECTRIC HEAT MINIMUM SUPPLY AIR UNIT MODEL SIZE, NOMINAL TONS HEATER 6.5 VOLTAGE kW 7.5 8.5 10 12.5 MINIMUM SUPPLY AIR CFM 9 1950 2250 2550 N/A N/A 18 1950 2250 2550 3000 3750 1950 2250 2550 3000 3750 36 1950 2250 2550 3000 3750 54 N/A N/A N/A 3500 4000 9 1950 2250 2550 N/A N/A 18 1950 2250 2550 3000 3750 208/230 24 1950 2250 2550 3000 3750 36 480 1950 2250 2550 3000 3750 54 N/A N/A N/A 3000 3750 9 1950 2250 2550 N/A N/A 1950 2250 2550 3000 3750 1950 2250 2550 3000 3750 36 1950 2250 2550 3000 3750 54 N/A N/A N/A 3500 3750 24 18 600 24 TABLE 39: INDOOR BLOWER SPECIFICATIONS MODEL BA-06 BA-07 BA-08 BA-10 BA-12 MOTOR MOTOR SHEAVE BLOWER SHEAVE BELT HP RPM Eff. SF Frame Datum Dia. (in.) Bore (in.) Model Datum Dia. (in.) Bore (in.) Model 1-1/2 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 9.5 1 AK99 A58 2 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 7.5 1 AK79 A55 2 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 6.5 1 AK69 A49 3 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 6.0 1 AK64 A49 2 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 9.0 1 AK94 A56 3 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 7.0 1 AK74 A54 2 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 8.5 1 AK89 A56 3 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 7.0 1 AK74 A54 3 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 7.0 1 AK74 A54 5 1725 87% 1.15 184T 4.3 - 5.3 1-1/8 1VP56 6.7 1 BK77 BX56 TABLE 40: POWER EXHAUST SPECIFICATIONS POWER EXHAUST MODEL VOLT PHASE 2PE0473225 2PE0473246 2PE0473258 208/230 460 575 1 1 1 * MOTOR HP 0.75 RPM* 1075 1050 ELECTRICAL QTY 1 LRA FLA MCA FUSE SIZE [email protected] 0.1 ESP 24.9 5.0 2.2 1.5 6.3 2.8 1.9 10 5 4 3,800 N/A Motors are multi-tapped and factory wired for high speed. Johnson Controls Unitary Products 37 262874-BTG-C-1208 Y X FRONT LEFT Unit Model Number X Y BA-06 47 1/2 25 1/2 F R O N T L E F T B C BA-07 38 23 BA-08 47 1/2 25 1/2 BA-10 47 1/2 25 1/2 BA-12 47 1/2 25 1/2 A FIGURE 3 D UNIT CENTER OF GRAVITY FIGURE 2 - UNIT 4 POINT LOAD TABLE 41: 4 POINT LOAD WEIGHT Location (lbs.) Model 38 A B C D BA-06 241 206 300 352 BA-07 199 148 232 311 BA-08 257 220 321 375 BA-10 265 226 330 386 BA-12 263 224 327 383 F R O N T L E F T A D C B E F FIGURE 4 - UNIT 6 POINT LOAD Johnson Controls Unitary Products 262874-BTG-C-1208 TABLE 42: 6 POINT LOAD WEIGHT TABLE 43: UNIT WEIGHT Locations (lbs.) Model Model Shipping Weight (lbs.) Operating Weight (lbs.) BA-06 1104 1099 A B C D E F BA-07 895 890 BA-06 165 148 134 195 216 241 BA-08 1178 1173 BA-07 139 113 94 147 128 218 BA-10 1212 1207 BA-12 1202 1197 BA-08 176 158 143 208 231 257 Econ. 85 84 BA-10 181 163 147 214 237 264 w/ PE 150 148 BA-12 180 161 146 213 235 262 Elec. Heat* 49 49 * 54kW heater 30-11/32 X Power Entry Ø 2-1/2 Control Entry Ø 7/8 Power Entry Ø 2-1/2 4-1/4 Convenience Power Outlet Entry Ø 7/8 30-3/16 59 FRONT 17-3/16 24-3/16 For Drain Dimensions See Detail B 6-3/16 LEFT For Baserail Dimensions See Detail A 89 27 FIGURE 5 - UNIT DIMENSIONS TABLE 44: UNIT HEIGHT Unit Model Number X BA-06 50 3/4 BA-07 42 BA-08 50 3/4 BA-10 50 3/4 BA-12 50 3/4 Johnson Controls Unitary Products TABLE 45: UNIT CLEARANCES Top* 72” Right 12” Front 36” Left 36” 36” Bottom‡ 0” Rear† * Units must be installed outdoors. Overhanging structure or shrubs should not obstruct condenser air discharge outlet. † To remove the slide-out drain pan, a rear clearance of 60” is required. If space is unavailable, the drain pan can be removed through the front by separating the corner wall. ‡ Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. 39 262874-BTG-C-1208 2 -3 /8 DETAIL A DETAIL B 3 -3 /4 5-3/8 3/4" Drain Opening 3 -9 /1 6 58 1/4 88 1/4 39 1/2 or 47 1/2 Outside Air Intake Hood 35 3/4 Relief Hood for Power Exhaust or Barometric Relief 26 25 3/4 26 30 1/4 FIGURE 6 - DOWNFLOW ECONOMIZER HOOD DETAIL TABLE 46: ECONOMIZER USAGE Application Cabinet Height Description Model Bottom Return All Downflow economizer with barometric relief 2EE04705424 Side Return All Horizontal economizer without barometric relief 2EE04705524* 42" Slab Economizer, 42” tall cabinet 2EE04705624† 50" Slab Economizer, 50” tall cabinet 2EE04705224† ERV or End Return * Barometric relief must be ordered seperately and installed in duct work. † Barometric relief or fresh air hood not included. Must be ordered seperately. 40 Johnson Controls Unitary Products 262874-BTG-C-1208 2EE04705424 Fresh Air Hood FIGURE 7 - 2EE04705424 Barometric Relief Hood FACTORY INSTALLED DOWNFLOW ECONOMIZER 2EE04705424 Fresh Air Hood FIGURE 8 - 2EE04705424 2EE04705424 2EE04705424 Fresh Air Damper Return Air Damper Barometric Relief Damper 2EE04705424 2EE04705424 Fresh Air Damper Return Air Damper 2PE047032XX Power Exhaust 2EE04705424 Barometric Relief Damper 2EE04705424 Barometric Relief Hood FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST Johnson Controls Unitary Products 41 262874-BTG-C-1208 2EE04705524 Return Air Damper Field Installed Duct Work 2EE04705524 Fresh Air Damper 2PE047032XX Power Exhaust FIGURE 9 - 1EH0408 Barometric Relief Damper 1EH0408 Barometric Relief Hood 2EE04705524 Fresh Air Hood FIELD INSTALLED HORIZONTAL ECONOMIZER W/POWER EXHAUST 1EH0409 Fresh Air Hood 2EE04705X24 Slab Economizer 2PE047032XX Power Exhaust 1EH0409 Barometric Relief Damper 1EH0409 Barometric Relief Hood FIGURE 10 - SLAB ECONOMIZER DOWNFLOW W/POWER EXHAUST 42 Johnson Controls Unitary Products 262874-BTG-C-1208 1EH0409 Fresh Air Hood Field Installed Duct Work 2EE04705X24 Slab Economizer 1EH0409 Barometric Relief Hood 1EH0409 Barometric Relief Damper 2PE047032XX Power Exhaust FIGURE 11 - SLAB ECONOMIZER END RETURN W/POWER EXHAUST R IG H T 8 0 -5 /8 IN S U L A T E D D E C K U N D E R C O N D E N S E R S E C T IO N 2 0 2 0 S U P P L Y 6 R E T U R N 2 T Y P . 3 0 IN S U L A T E D D E C K U N D E R C O M P R E S S O R S E C T IO N 5 0 -1 /2 8 o r 1 4 F R O N T FIGURE 12 - ROOF CURB DIMENSIONS Johnson Controls Unitary Products 43 262874-BTG-C-1208 2 T Y P 5 0 -1 /2 2 3 3 0 -1 /2 4 8 0 -5 /8 2 6 R E T U R N S U P P L Y 1 0 7 6 -5 /8 5 9 -1 /4 9 4 F R O N T 6 4 -1 /4 R IG H T FIGURE 13 - TRANSITION ROOF CURBS 3 2 -1 1 /1 6 6 -1 3 /1 6 6 -1 3 /1 6 S U P P L Y A IR R E T U R N A IR 6 -1 3 /1 6 2 4 2 7 -1 /2 L E F T 2 1 1 8 1 9 -3 /1 6 2 1 -3 /1 6 1 7 -3 /1 6 1 4 -2 3 /3 2 7 -1 /8 1 6 -3 /8 B o tto m C o n d e n s a te L o c a tio n 1 8 -1 /1 6 B o C o C o O u E n tto m P o w e r, n tro l a n d n v e n ie n c e tle t W ir in g try F R O N T 1 9 -5 /8 FIGURE 14 - BOTTOM DUCT OPENINGS (FROM ABOVE) 44 Johnson Controls Unitary Products 262874-BTG-C-1208 18-1/4 Dot Plugs REAR DUCT DIMENSIONS CABINET SIZE DIMENSION “A” “B” “C” 50 3/4” 28 1/4 18 1/16 28 1/4 42” 27 3/4 12 1/16 27 1/2 Supply Air 18-1/4 5-5/32 A Return Air Patch Plate For Slide-Out Drain Pan B 2-31/32 C 31-11/16 FIGURE 15 - REAR DUCT DIMENSIONS Johnson Controls Unitary Products 45 262874-BTG-C-1208 FIGURE 16 - TYPICAL 6-1/2 TON HEAT PUMP WITH OR WITHOUT ELECTRIC HEAT WIRING DIAGRAM 46 Johnson Controls Unitary Products 262874-BTG-C-1208 FIGURE 17 - TYPICAL 7-1/2 - 12-1/2 TON HEAT PUMP WITH OR WITHOUT ELECTRIC HEAT WIRING DIAGRAM Johnson Controls Unitary Products 47 262874-BTG-C-1208 GUIDE SPECIFICATIONS BA-06, -07, -08, -10 & -12 9.3-10.7 EER GENERAL INDOOR (EVAPORATOR) FAN ASSEMBLY UP BA heat pump units are convertible single packages with a common footprint cabinet and common roof curb for all 6-1/ 2 through 12-1/2 ton models. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All BA heat pump units are selfcontained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage sizes. Fan shall be a belt drive assembly and include an adjustable pitch motor pulley. Job site selected brake horsepower shall not exceed the motors nameplate horsepower rating plus the service factor. Units shall be designed to operate within the service factor. Fan wheel shall be double inlet type with forward curve blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Entire blower assembly and motor shall be slide out design. DESCRIPTION Units shall be factory assembled, single package, designed for outdoor installation. Units shall have a minimum EER of 9.3. They shall have built in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return and be available with factory installed options or field installed accessories. The units shall be factory wired, piped and charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. The cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be CSA certified to ANSI Z21.47 and UL 1995/CAN/CSA No. 236M90 standards. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. REFRIGERANT COMPONENTS Compressor(s): a. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of + or – 10% of the unit nameplate voltage. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. UNIT CABINET Unit cabinet shall be constructed of G90 galvanized steel with exterior surfaces coated with a non-chalking, powder paint finish, certified at 1000 hours salt spray test per ASTM-B117 standards. Indoor blower sections shall be insulated with up to 1” thick insulation coated on the airside. Aluminum foil faced insulation shall be used in the unit’s compartments and be fastened to prevent insulation from entering the air stream. Cabinet doors shall be hinged with toolless access for easy servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, fork truck access and proper sealing on roof curb applications. Disposable 2” filters shall be furnished and be accessible through hinged access door. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating bypass of the coils. Condensate pan shall be slide out design, constructed of a non corrosive material, internally sloped and conforming to ASHRAE 62-B9 standards. Condensate connection shall be a minimum of ¾” I.D. female and be rigid mount connection. 48 Coils: a. evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator and condenser coils shall be of the direct expansion, draw-thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed-orifice or thermally operated expansion devices. b. Solid core filter drier/strainer to eliminate any moisture or foreign matter. Johnson Controls Unitary Products 262874-BTG-C-1208 c. d. Accessible service gage connections on both suction and discharge lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. The unit shall have two independent refrigerant circuits, equally split in 50% capacity increments. Unit Controls: a. Unit shall be complete with self-contained low-voltage control circuit protected by a resetable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor: (1) loss-of-charge/Low-pressure switch. (2) High-pressure switch. (3) Freeze-protection thermostat, evaporator coil. If any of the above safety devices trip, a LED (lightemitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. c. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection. d. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. e. Unit control board shall have on-board diagnostics and fault code display. f. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0 °F. g. Control board shall monitor each refrigerant safety switch independently. h. Control board shall retain last 5 fault codes in non volatile memory, which will not be lost in the event of a power loss. UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125 °F outdoor temperature, exceeding maximum load criteria of ARI Standard 340/360. The compressor, with standard controls, shall be capable of operation down to 0 °F outdoor temperature. ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES Compressor – 5 Years, Elect. Heat Elem. – 5 Years, Parts – 1 Year FACTORY INSTALLED OPTIONAL OUTDOOR AIR (Shall be made available by either/or): 1. ELECTRONIC ENTHALPY ECONOMIZER – Outdoor and return air dampers that are interlocked and positioned by a fully-modulating, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixed-air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55 °F. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. Available with barometric relief or power exhaust. 2. MOTORIZED OUTDOOR AIR DAMPERS – Outdoor and return air dampers that are interlocked and positioned by a 2-position, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of ELECTRIC HEATING SECTION An electric heating section, with nickel chromium elements, shall be provided in a range of 9 thru 54 KW, offering two states of capacity all sizes. The heating section shall have a primary limit control(s) (automatic reset) to prevent the heating element system from operating at an excessive temperature. The Heating Section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating Sections shall be wired for a single point power supply with branch circuit fusing (where required). Johnson Controls Unitary Products 49 262874-BTG-C-1208 two pre-selected positions – regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss. • DISCONNECT SWITCH - For heat pump units only, a disconnect switch sized to the largest electric heat available, can be factory installed. • ELECTRIC HEATER - The electric heater ranges from 9 kW to 54 kW and is available in all the voltage options of the base unit. • SMOKE DETECTOR – A smoke detector can be factory mounted and wired in the supply and/or return air compartments. ADDITIONAL FACTORY INSTALLED OPTIONS • ALTERNATE INDOOR BLOWER MOTOR – For applications with high restrictions, units are available with optional indoor blower motors that provide higher static output and/or higher airflow. • CONVENIENCE OUTLET (NON POWERED/POWERED) – Unit can be provided with an optional 120VAC GFCI outlet with cover on the corner of the unit housing the compressors. • PHASE MONITOR - Designed to prevent damage in outof-phase condition. • COIL GUARD - Designed to prevent condenser coil damage. • BAS CONTROLS - Include supply air sensor, return air sensor, dirty filter indicator and air proving switch. • DIRTY FILTER SWITCH – This option includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high-pressure drop across the filters. • STAINLESS STEEL DRAIN PAN – Provides years of trouble-free operation in corrosive environments. • BREAKER – For heat pumps with electric heat, an HACR breaker can be factory installed on the unit. 50 OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE • ROOF CURB - 14” and 8” high, full perimeter knockdown curb, with hinged design for quick assembly. • BAROMETRIC RELIEF DAMPER – (Unit mounted – Downflow, Duct Mounted – Horizontal) – Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit during economizer operation. • DIRTY FILTER SWITCH • ECONOMIZER (Downflow and Horizontal) • POWER EXHAUST – (Unit mount – Downflow, Duct mount – Horizontal) • DUAL ENTHALPY KIT - Provides a second input to economizer to monitor return air. Johnson Controls Unitary Products 262874-BTG-C-1208 Johnson Controls Unitary Products 51 Subject to change without notice. Printed in U.S.A. Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 262874-BTG-C-1208 Supersedes: 262874-BTG-B-0606
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement